218-219.qxp 5/27/2011 2:29 PM Page 219 Myers™ Hubs Applications: Hub Basic Scru-Tite® – NEMA 2, 3, 3R, 4, 4X and 12 • Myers™ Scru-tite® and Ground hub are used in the termination of electrical circuits through wall of the enclosure Zinc UL File No. E-27258 • Ideal for pharmaceutical, chemical and food processing, pulp/paper and nuclear industries. • The O-ring is a special "Viton (75)" and has excellent chemical resistance. • Hub is provided with a stainless steel ground nut. Features: • Vibration proof • Grounding screw for added safety • Captive o-ring gasket • No welding • Posi-Lok insulated throat (insuliner) • Fit standard knockouts • Easy installation Cat. # Size Unit Qty. Wt. Lbs. Per 100 ST ST ST ST ST ST ST ST ST ST ST ST ST /8" /2" 3 /4" 1" 11/4" 11/2" 2" 21/2" 3" 31/2" 4" 5" 6" 25 25 25 25 10 10 10 5 2 2 2 1 1 12 20 32 40 60 70 90 200 250 300 350 600 800 03† 1† 2† 3† 4† 5† 6† 7† 8 9 10 11* 12* 3 1 CP • Resistant to a variety of chemicals, including acetic, citric and salt water. †Optional Nickel-Chrome Plate Finish. Add suffix -CP. See price list. *Not supplied with insulator. • Controlled thread lengths • NPSL on male thread Hub Basic Scru-Tite® – NEMA 2, 3, 3R, 4, 4X and 12 • No sharp edges (along parting line) Aluminum UL File No. E-27258 Certifications and Compliances: • NEC/CEC: Class I, Division 2 Class II, Division 1 & 2 Cat. # Size Unit Qty. Wt. Lbs. Per 100 1 • Insuliner: Lexan STA STA STA STA STA STA STA STA STA STA STA STA / 2" / 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" 25 25 25 10 10 10 5 2 2 2 1 1 8 16 16 30 30 50 80 100 150 150 300 300 • O-Ring: Gasket Vi Ton *Not supplied with insulator. Class III, Division 1 & 2 • UL Listed – UL Standard 514B • CSA Certified – Certified by UL to CSA standard C22.2 No. 18 • NEMA Type 2, 3, 3R, 4, 4X, 12 (std hub) • NEMA Type 2, 3, 3R, 4, 4X, 12 (ground hub) Standard Materials: • Nut: Zamek-2, Zamek-3, Aluminium (Al 360), Stainless (316) • Body: Zamek-2, Zamek-3, Aluminium (Al 360), Stainless (316) • Ground Screw: Steel 1 2 3 4 5 6 7 8 9 10 11* 12* 3 Stainless Steel Ground Hub – NEMA 2, 3, 3R, 4, 4X and 12 Standard Finishes: Stainless Steel – Type 316 UL File No. E-59509 • Aluminum: Natural • Zinc: Natural Optional Materials and Finishes: • Stainless: Natural • Zinc: Chrome-plate Cat. # SSTG SSTG SSTG SSTG SSTG SSTG SSTG SSTG SSTG SSTG www.crouse-hinds.com US: 1-866-764-5454 1 2 3 4 5 6 7 8 9 10 Size Unit Qty. Wt. Lbs. Per 100 /2" /4" 1" 11/4" 11/2" 2" 21/2" 3" 31/2" 4" 10 10 10 5 5 5 2 2 2 2 20 30 43 55 73 95 — — — — 1 3 CAN: 1-800-265-0502 Copyright© 2011 Cooper Crouse-Hinds 219 220-221.qxp 5/27/2011 2:30 PM Page 220 Myers™ Hubs Ground Hub – NEMA 2, 3, 3R, 4, 4X and 12 Ground Hub Basic Scru-Tite® Zinc Zinc ATEX Approval with DEMKO 07 ATEX 0618172U UL File No. E-59509 Class I, Zone 1, AEx e II Class I, Zone 1, Ex e II CP II 2 G Ex e II UL File No. 187273 Max. Copper Grd. Wire Size Cat. # Size Unit Qty. Wt. Lbs. Per 100 CSA UL Cat. # STG STG STG STG STG STG STG STG STG STG STG STG /2" /4" 1" 11/4" 11/2" 2" 21/2" 3" 31/2" 4" 5" 6" 25 25 25 10 10 10 5 2 2 2 1 1 20 30 43 55 73 95 190 263 300 350 625 750 #8 #8 #8 #8 #6 #4 #2 1/ 2/ 2/ 2/ 3/ #8 #8 #8 #8 #8 #8 #6 #6 #6 #4 #2 #1 STGK STGK STGK STGK STGK STGK 1 2 3 4 5 6 7 8 9 10 11* 12* 1 3 0 0 0 0 0 1 2 3 4 5 6 Size Unit Qty. Wt. Lbs. Per 100 /2" /4" 1" 11/4" 11/2" 2" 10 10 10 5 5 5 20 30 43 55 73 95 1 3 Stainless Steel – Type 316 ATEX Approval with DEMKO 07 ATEX 0618172U II 2 G Ex e II Class I, Zone 1, AEx e II UL File No. E-187273 Class I, Zone 1, Ex e II *Not supplied with insulator Ground Hub – NEMA 2, 3, 3R, 4, 4X and 12 Aluminum – Type 360 Cat. # Max. Copper Grd. Wire Size Cat. # STAG STAG STAG STAG STAG STAG STAG STAG STAG STAG STAG STAG 220 1 2 3 4 5 6 7 8 9 10 11 12 Size Unit Qty. Wt. Lbs. Per 100 CSA UL /2" 3 /4" 1" 11/4" 11/2" 2" 21/2" 3" 31/2" 4" 5" 6" 25 25 25 10 10 10 5 2 2 2 1 1 10 14 18 25 33 45 90 125 138 150 325 350 #8 #8 #8 #8 #6 #4 #2 1/ 2/ 2/ 3/ 3/ #8 #8 #8 #8 #8 #8 #6 #6 #6 #4 #2 #1 1 www.crouse-hinds.com US: 1-866-764-5454 0 0 0 0 0 CAN: 1-800-265-0502 SSTGK SSTGK SSTGK SSTGK SSTGK SSTGK 1 2 3 4 5 6 Size Unit Qty. Wt. Lbs. Per 100 /2" /4" 1 11/4" 11/2" 2 10 10 10 5 5 5 20 30 43 55 73 95 1 3 Ground Nut Zinc Max. Copper Grd. Wire Size Cat. # STGN STGN STGN STGN STGN STGN 1 2 3 4 5 6 Size Unit Qty. Wt. Lbs. Per 100 CSA UL /2" 3 /4" 1" 11/4" 11/2" 2" 25 25 25 10 10 10 6 10 13 15 23 30 #8 #8 #8 #8 #6 #4 #8 #8 #8 #8 #8 #8 1 Copyright© 2011 Cooper Crouse-Hinds 220-221.qxp 5/27/2011 2:30 PM Page 221 Myers™ Hubs Ground Nut Through-Bulkhead Fitting Aluminum Aluminum Packaged as two pieces unassembled STAGN STAGN STAGN STAGN STAGN STAGN Size 1 2 3 4 5 6 /2" /4" 1" 11/4" 11/2" 2" 1 3 Unit Qty. Wt. Lbs. Per 100 25 25 25 10 10 10 3 5 6 8 10 13 #8 #8 #8 #8 #6 #4 Cap-Off #8 #8 #8 #8 #8 #8 Cat. # STTBA STTBA STTBA STTBA STTBA STTBA STTBA STTBA 1* 2* 3* 4* 5* 6* 7 8 Size Unit Qty. Wt. Lbs. Per 100 /2" 3 /4" 1" 11/4" 11/2" 2" 21/2" 3" 5 5 5 5 5 5 4 2 20 35 30 40 50 70 106 138 1 CP Cat. # Max. Copper Grd. Wire Size CSA UL *UL Listed Zinc Through-Bulkhead Fitting without nipples Zinc Packaged as two pieces unassembled Cat. # Size Unit Qty. Wt. Lbs. Per 100 STC STC STC STC STC STC /2" 3 /4" 1" 11/4" 11/2" 2" 25 25 25 10 10 10 13 20 28 40 53 70 1 2 3 4 5 6 1 Cap-Off Aluminum Cat. # STTTB STTTB STTTB STTTB STTTB STTTB 1 2 3 4 5 6 Size Unit Qty. Wt. Lbs. Per 100 / 2" 3 / 4" 1" 11/ 4" 11/ 2" 2" 5 5 5 5 5 5 35 60 75 85 120 170 1 Through–Bulkhead Fitting without nipples Aluminum Cat. # Size Unit Qty. Wt. Lbs. Per 100 STAC 1 STAC 2 STAC 3 /2" 3 /4" 1" 25 25 25 6 8 12 1 Through-Bulkhead Fitting Zinc Cat. # STTB 1* STTB 2* STTB 3* STTB 4* STTB 5* STTB 6* STTB 7 STTB 8 STTB 9 STTB 10 Size /2" 3 /4" 1" 11/4" 11/2" 2" 21/2" 3" 31/2" 4" 1 Unit Qty. 5 5 5 5 5 5 4 2 2 2 Cat. # STTTBA STTTBA STTTBA STTTBA STTTBA STTTBA 1 2 3 4 5 6 Size Unit Qty. Wt. Lbs. Per 100 /2" 3 /4" 1" 11/4" 11/2" 2" 5 5 5 5 5 5 15 25 35 40 50 75 1 Wt. Lbs. Per 100 30 50 70 85 110 160 244 312 350 400 *UL Listed www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2011 Cooper Crouse-Hinds 221 222-223.qxp 5/27/2011 2:31 PM Page 222 CP Myers™ Hubs Non-Hazadous Drain Plug Metric To NPT Adapter Stainless Steel UL File No. E-23223 Zinc Cat. # Size Unit Qty. Wt. Lbs. Per 100 SSTC 1 SSTC 1CD 1 /2" /2" 25 10 13 13 Note: 1 SSTC-1 is for knockouts and is supplied with a locknut and straight threads. SSTC-1CD is for threaded openings and is supplied without locknut and NPT threads. Not gasketed to allow for water drainage Cat. # Size STM STM STM STM STM STM M20 M25 M32 M40 M50 M63 Note: Non-Hazadous Drain Plug Aluminum UL File No. E-23223 1 2 3 4 5 6 Unit Qty. Wt. Lbs. Per 100 25 25 25 10 10 10 12 32 32 40 50 70 Metric To NPT Adapter Stainless Steel Size Unit Qty. Wt. Lbs. Per 100 Cat. # STAC 1ST STAC 1CD 1 /2" 1 /2" 25 25 6 6 SSTM SSTM SSTM SSTM SSTM SSTM 222 /2" 3 /4" 1" 11/4" 11/2" 2" 1 The Myers Metric to NPT hub adapter is used to convert a threaded metric entry to a NPT entry. The female thread is NPT and the male thread is metric. Cat. # Note: to to to to to to STAC-1ST is for knockouts and is supplied with a locknut and straight threads. STAC-1CD is for threaded openings and is supplied without locknut and NPT threads. Not gasketed to allow for water drainage www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Size 1 2 3 4 5 6 M20 M25 M32 M40 M50 M63 to to to to to to /2" 3 /4" 1" 11/4" 11/2" 2" 1 Copyright© 2011 Cooper Crouse-Hinds Unit Qty. Wt. Lbs. Per 100 10 10 10 5 5 5 12 20 32 40 50 70 222-223.qxp 5/27/2011 2:31 PM Page 223 Myers™ Hubs SCHEDULE OF DIMENSIONS Pipe Size J "O" Ring K Cat. # A B C D Min. Max. F G H C.S. O.D. Min. Max. /4 3 /8 1 /2 3 /4 1 11/4 11/2 2 21/2 3 31/2 4 5 6 ST ST ST ST ST ST ST ST ST ST ST ST ST ST 13/2 13/2 111/32 115/32 121/32 111/16 111/16 13/4 27/32 25/16 23/8 27/16 215/16 3 /16 11/8 17/16 123/32 2 23/8 23/4 31/4 33/4 43/8 5 51/2 67/8 711/16 /32 21 /32 13 /16 29 /32 11/32 11/32 11/32 13/32 19/32 13/8 17/16 11/2 2 2 1 /8 1 /8 3 /16 3 /16 1 /4 1 /4 1 /4 1 /4 1 /4 1 /4 1 /4 1 /4 1 /4 5 /16 .350 .468 .591 .783 .997 1.311 1.529 1.964 2.346 2.915 3.371 3.825 4.795 5.762 .364 .493 .622 .824 1.049 1.380 1.610 2.067 2.469 3.068 3.548 4.026 5.047 6.065 1 /4 NPT 3 /8 NPT 1 /2 NPT 3 /4 NPT 1 NPT 11/4 NPT 11/2 NPT 2 NPT 21/2 NPT 3 NPT 31/2 NPT 4 NPT 5 NPT 6 NPT /4 NPS 3 /8 NPS 1 /2 NPS 3 /4 NPS 1 NPS 11/4 NPS 11/2 NPS 2 NPS 21/2 NPS 3 NPS 31/2 NPS 4 NPS 5 NPS 6 NPS 60° 60° 60° 60° 60° 60° 60° 60° 60° 45° 45° 45° 45° 45° 3 /21 3 /32 1 /8 1 /8 1 /8 1 /8 1 /8 1 /8 1 /8 1 /8 1 /8 1 /8 1 /8 1 /8 /4 15 /16 11/2 17/16 13/4 21/8 21/2 3 31/2 41/8 45/8 51/8 61/2 71/4 35 /64 43 /64 55 /64 11/16 121/64 143/64 159/64 225/64 257/64 333/64 41/64 433/64 537/64 641/64 /16 /16 7 /8 11/8 13/8 13/4 2 21/2 3 35/8 41/8 45/8 511/16 63/4 1 E 15 21 1 3 9 11 CP 02 03† 1† 2† 3† 4† 5† 6† 7† 8 9 10 11* 12* *Not supplied with insulator. Options: Description † Optional Nickel-Chrome Plate Finish. See price list. Tolerance Decimal Fractional Angular & Draft +/–.010 +/–1/16 +/–2° Suffix -CP Cat. # Material ST STA SSTG Zinc Aluminium Stainless Dimensions and materials specified are subject to change without prior notice. PLAN VIEW SIDE VIEW SPACING CHART FOR MYERS HUBS "D" dimension indicated maximum panel thickness which hub will accommodate. CONDUIT OR PIPE SIZE HOLE COND. SIZE. SIZE. /16 11 /16 7 /8 11/8 13/8 13/4 2 21/2 3 35/8 41/8 45/8 511/16 63/4 9 /4 3 /8 1 /2 3 /4 1 11/4 11/2 2 21/2 3 31/2 4 5 6 1 /4 1 1 /16 15/32 15/16 17/16 19/32 125/32 131/32 27/32 215/32 225/32 33/32 311/32 41/32 413/32 19 /32 /8 3 /2 1 /4 1 11/4 11/2 2 21/2 3 31/2 4 5 6 113/16 131/32 25/32 211/32 219/32 227/32 35/32 315/32 323/32 413/32 425/32 31 /32 21/8 25/16 21/2 23/4 3 35/16 35/8 37/8 49/16 415/16 11/8 21/2 211/16 215/16 33/16 31/2 313/16 41/16 43/4 51/8 15/16 27/8 31/8 33/8 311/16 4 41/4 415/16 55/16 11/2 33/8 35/8 315/16 41/4 41/2 53/16 59/16 13/4 37/8 43/16 41/2 43/4 57/16 513/16 2 41/2 413/16 51/16 53/4 61/8 25/16 51/8 53/8 61/16 67/16 25/8 53/4 63/16 611/16 27/8 71/8 73/8 39/16 73/4 315/16 3 1 11/4 113/32 117/32 111/16 17/8 21/16 25/16 29/16 27/8 33/16 37/16 41/8 41/2 11 /16 19/16 111/16 127 /32 21/32 27/32 215/32 223/32 31/32 311/32 319/32 49/32 421/32 27/32 Minimum space from center of pipe or conduit to nearest obstruction. 1. Dimensions in dark gray shaded squares are centers for conduits of same size. Example: How close may 3 conduits be spaced? Answer 41/2" 2. Dimensions in lighter gray shaded squares are for centers of conduits NOT of the same size. Example: What is the minimum spacing for 2" and 3/4" conduit? Read down column marked 3/4" to figure opposite 2" and find dimensions is 211/32". 3. Minimum spacing dimensions as shown will give approximately 1/8" clearance between locking nuts. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2011 Cooper Crouse-Hinds 223