International Metallic Cable Gland Solutions Global Cable Gland Solutions For more than 100 years, companies have come to rely on Cooper Crouse-Hinds for value they can trust to grow their business. Our comprehensive offering of electrical products meet customer application requirements in the most demanding industrial and commercial environments worldwide. Our customer-first commitment to combine premium quality and reliability with superior technical support successfully minimizes downtime, reduces repair incidence, and improves safety and productivity. Every product we develop and every solution we engineer is clearly focused on lowering our customer’s total cost of ownership. Global termination solutions moving power and signals in the world’s most demanding environments From the deserts of Africa to the icy waters of the North Sea, the world turns to Cooper CrouseHinds for its complete gland solutions. Our cable glands are used in industrial and commercial applications throughout the world engineering safety and productivity in the most severe environmental conditions. Cooper Crouse-Hinds’ global offering provides a termination solution for virtually every cable type used in hazardous and industrial environments. These glands are designed for strict adherence to global specifications meeting North American and international codes and standards, including NEC, CEC, ATEX, IECEx, and regional certifications. 2 GLOBAL CABLE GLAND SOLUTIONS Cooper Crouse-Hinds cable glands are the easiest and safest solution for your installation and maintenance needs. In any electrical or instrumentation installation, our glands are the reliable and safe way to move power and signals. Global manufacturing presence and local inventory provides for flexibility in meeting our customers’ installation and project coordination schedules. The result is best-in-class on-time delivery, customer satisfaction, and service. Our first-class technical gland team is available to support product application, technical specification, and onsite installation training on a global basis. Time-tested, quality cable glands from Cooper Crouse-Hinds offer: International Metallic Cable Gland Solutions • Complete termination solutions for global cable applications • Increased safety, flameproof, and explosionproof terminations for harsh and hazardous environments • Global certifications • Standard in nickel-plated brass with options for stainless steel, aluminum, and bronze • Full line of accessories, including adapters, unions, and reducers • Complete termination solution for global cable applications • Ease of cable termination providing labor and time management productivity • Explosion-protected connections contributing to safe operation in harsh and hazardous environments • Delivery meeting installation and project coordination schedules GLOBAL CABLE GLAND SOLUTIONS 3 Quick Selection Guide International Standards CABLE GLAND CABLE TYPE ILLUSTRATION ADE 1F (page 5) ADE 4F (page 6) ADE 6F (page 7) ADE 1FC (page 8) ADE 6FC (page 9) QUICK SELECTION GUIDE STANDARD MATERIAL CERTIFICATION PROTECTION TYPE Non-armoured and armoured (does not terminate the armour) Nonarmoured Nickelplated brass Flameproof & Increased Safety SWA, SWB, STA, braided marine shipboard and lead sheathed (with addition of earthing washer) Armoured Nickelplated brass Flameproof & Increased Safety SWA, SWB, STA and braided marine shipboard Armoured Nickelplated brass Flameproof & Increased Safety Non-armoured and armoured (does not terminate the armour) Nonarmoured Barrier Nickelplated brass Flameproof, Increased Safety, & Explosionproof SWA, SWB, STA and braided marine shipboard Armoured Barrier Nickelplated brass Flameproof, Increased Safety, & Explosionproof International metallic cable glands also feature Lloyds, DNV, and ABS certifications. 4 GLAND TYPE ADE 1F F B A G E Gland Type Non-armoured Features Cable Type Non-armoured and armoured (does not terminate the armour) Certifications and Compliances • LCIE 97 ATEX 6008X II 2 GD – Exd IIC/Exe II/Ex tD • IECEx LCI 05.0004X – Exd IIC/Exe II/Ex tD • cULus Listed for Class I, Zone 2 AEx e II/Ex e II • cULus Marine Listed for Class I, Zone 1 AEx e II /Ex e II • NEMA 4X and IP68 • CEPEL-EX-558/05X • GOST-R POCC FR.B03126 • NEPSI N° GYJ071336U & GYJ071337U • DNV N° E-10892 • ABS approbation: n° 10-HS 577243-PDA / P1836754-X • Lloyds • Standard material is nickel-plated brass for superior corrosion resistance • Provides a flameproof and weatherproof seal on the outer sheath of the cable • Standard neoprene seal suitable for use in operating temperatures ATEX (-60°C to 100°C), IECEx and cULus (-40°C to 100°C) • Available with optional silicone seal for extreme temperatures • Available with metric or NPT threads • See page 10 for related accessories OPTIONS (replace last digit with option number): ORDERING EXAMPLE: 9 8 7 5 Stainless steel (316L) Bronze Aluminum Silicone sealing ring with temperature range of -70°C to 220°C K1 Includes locknut and fiber washer K2 Includes locknut, fiber washer, earth tag, and shroud CAP81640 4 KX Gland Type Options SELECTION TABLE Entry Thread Size ‘A’ Cable Acceptance Hexagon Dimensions NPT Size NPT Catalog No. Thread Length ‘B’ Metric (NPT) ⁄4" CAP818404 15 (12.0) 4.0 8.0 20.0 – 16.5 ⁄8" CAP818594 15 (12.0) 4.0 8.5 20.0 – 20.9 ⁄8" CAP818504 15 (12.0) 6.0 12.0 22.0 – 20.9 ⁄2" CAP818674 15 (20.2) 4.0 8.5 20.0 – 26.4 ⁄2" CAP818694 15 (20.2) 6.0 12.0 22.0 – 26.4 ⁄2" CAP818604 15 (20.2) 8.5 16.0 25.0 – 26.4 ⁄4" CAP818774 15 (20.2) 6.0 12.0 22.0 – 33.0 ⁄4" CAP818794 15 (20.2) 8.5 16.0 25.0 – 33.0 3 ⁄4" CAP818704 15 (20.2) 12.0 21.0 27.0 – 33.0 CAP816894 1" CAP818894 15 (25.3) 12.0 21.0 27.0 – 39.6 M32 CAP816804 1" CAP818804 15 (25.3) 16.0 27.5 34.0 – 45.1 8 M40 CAP816994 1-1⁄4" CAP818994 15 (26.0) 16.0 27.5 34.0 – 48.4 9 M40 CAP816904 1-1⁄4" CAP818904 15 (26.0) 21.0 34.0 36.0 – 52.8 9 M50 CAP817094 1-1⁄2" CAP819094 15 (26.5) 21.0 34.0 36.0 – 60.5 10 M50 CAP817004 1-1⁄2" CAP819004 15 (26.5) 27.0 41.0 39.0 – 60.5 11 M63 CAP817294 2" CAP819294 17 (27.2) 33.0 48.0 41.0 – 73.7 12 M63 CAP817204 2" CAP819204 17 (27.2) 40.0 56.0 43.0 – 79.2 12 M75 CAP817394 2-1⁄2" CAP819494 18 (40.5) 40.0 56.0 43.0 – 88.0 13 M75 CAP817304 2-1⁄2" CAP819404 18 (40.5) 47.0 65.0 49.0 – 93.5 14 M90 CAP817594 3" CAP819594 22 (42.0) 54.0 74.0 56.0 – 104.5 15 M90 CAP817504 3" CAP819504 22 (42.0) 63.0 78.0 61.0 – 121.0 16 M110 CAP817794 3-1⁄2" CAP819604 22 (43.2) 72.0 92.0 62.0 – 132.0 Gland Size Metric Size Metric Catalog No. 4 M12 CAP816404 1 4 M16 CAP816594 3 5 M16 CAP816504 3 4 M20 CAP816674 1 5 M20 CAP816694 1 6 M20 CAP816604 1 5 M25 CAP816774 3 6 M25 CAP816794 3 7 M25 CAP816704 7 M32 8 Max. Gland Length ‘F’ (less entry) Across Flats Across Corners ‘G’ Outer Sheath ‘E’ Min. All dimensions in millimeters unless otherwise noted. INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY 5 ADE 4F F B G E A D Gland Type Armoured Features Cable Type Steel wire armoured, steel wire braided, steel tape armoured, braided marine shipboard and lead sheathed (with addition of earthing washer) Certifications and Compliances • LCIE 97 ATEX 6008X II 2 GD – Exd IIC/Exe II/Ex tD • IECEx LCI 05.0004X – Exd IIC/Exe II/Ex tD • cULus Listed for Class I, Zone 2 AEx e II/Ex e II • cULus Marine Listed for Class I, Zone 1 AEx e II/ Ex e II • NEMA 4X and IP68 • CEPEL-EX-558/05X • GOST-R POCC FR.B03126 • NEPSI N° GYJ071336U & GYJ071337U • DNV N° E-10892 • ABS approbation: n° 10-HS 577243-PDA / P1836754-X • Lloyds • Standard material is nickel-plated brass for superior corrosion resistance • Armour clamping and bonding with no reversible components for easy installation, minimizing error • Provides flameproof seal on inner jacket and weatherproof seal on outer sheath of cable • Optional earthing washer for use with lead sheathed cable • Standard neoprene seal suitable for use in operating temperatures ATEX (-60°C to 100°C), IECEx and cULus (-40°C to 100°C) • Available with optional silicone seal for extreme temperatures • Available with metric or NPT threads • See page 10 for related accessories OPTIONS (replace last digit with option number): ORDERING EXAMPLE: 9 8 7 5 Stainless steel (316L) Bronze Aluminum Silicone sealing ring with temperature range of -70°C to 220°C K1 Includes locknut and fiber washer K2 Includes locknut, fiber washer, earth tag, and shroud CAP84640 4 KX Gland Type Options SELECTION TABLE Entry Thread Size ‘A’ Cable Acceptance Thread NPT Length ‘B’ Catalog No. Metric (NPT) CAP848404 15 (12.0) Min. 4.0 ⁄8" CAP848594 15 (12.0) ⁄8" CAP848504 15 (12.0) ⁄2" CAP848674 ⁄2" Gland Size 5 Metric Size M12 Metric Catalog No. CAP846404 NPT Size 1 ⁄4" 5 M16 CAP846594 3 6 M16 CAP846504 3 5 M20 CAP846674 1 6 M20 CAP846694 1 7 M20 CAP846604 1 6 M25 CAP846774 3 7 M25 CAP846794 3 8 M25 CAP846704 8 M32 9 Inner Sheath‘D’ Armour (max.) 0.9 Across Flats – Across Corners ‘G’ 20.9 Max. 8.0 Min. 6.0 Max. 12.0 4.0 8.5 6.0 12.0 0.9 36.0 – 20.9 6.0 12.0 8.5 16.0 1.25 42.0 – 26.4 15 (20.2) 4.0 8.5 6.0 12.0 0.9 36.0 – 26.4 CAP848694 15 (20.2) 6.0 12.0 8.5 16.0 1.25 42.0 – 26.4 ⁄2" CAP848604 15 (20.2) 8.5 16.0 12.0 21.0 1.25 46.0 – 33.0 ⁄4" CAP848774 15 (20.2) 6.0 12.0 8.5 16.0 1.25 42.0 – 33.0 ⁄4" CAP848794 15 (20.2) 8.5 16.0 12.0 21.0 1.25 46.0 – 33.0 3 ⁄4" CAP848704 15 (20.2) 12.0 20.5 16.0 27.5 1.6 56.0 – 45.1 CAP846894 1" CAP848894 15 (25.3) 12.0 21.0 16.0 27.5 1.6 56.0 – 45.1 M32 CAP846804 1" CAP848804 15 (25.3) 16.0 27.5 21.0 34.0 1.6 63.0 – 52.8 9 M40 CAP846994 1-1⁄4" CAP848994 15 (26.0) 16.0 27.5 21.0 34.0 1.6 63.0 – 52.8 10 M40 CAP846904 1-1⁄4" CAP848904 15 (26.0) 21.0 34.0 27.0 41.0 2.0 68.0 – 60.5 10 M50 CAP847094 1-1⁄2" CAP849094 16 (26.5) 21.0 34.0 27.0 41.0 2.0 68.0 – 60.5 11 M50 CAP847004 1-1⁄2" CAP849004 16 (26.5) 27.0 41.0 33.0 48.0 2.5 74.0 – 70.4 12 M63 CAP847294 2" CAP849294 17 (27.2) 27.0 41.0 33.0 48.0 2.5 77.0 – 79.2 13 M63 CAP847204 2" CAP849204 17 (27.2) 33.0 48.0 40.0 56.0 2.5 85.0 – 93.5 13 M75 CAP847394 2-1⁄2" CAP849494 18 (40.5) 40.0 56.0 47.0 65.0 2.5 85.0 – 93.5 14 M75 CAP847304 2-1⁄2" CAP849404 18 (40.5) 47.0 65.0 54.0 74.0 2.5 92.0 – 104.5 15 M90 CAP847594 3" CAP849594 22 (42.0) 54.0 74.0 63.0 83.0 3.15 104.0 – 121.0 16 M90 CAP847504 3" CAP849504 22 (42.0) 63.0 82.0 72.0 93.0 3.15 108.0 – 132.0 16 M90 CAP847574 3-1⁄2" CAP849604 N/A (43.2) 63.0 82.0 72.0* 93.0* 3.15 108.0 – 132.0 17 M110 CAP847794 4" CAP849704 22 (44.5) 72.0 92.0 85.0 107.0 3.15 115.0 – 148.5 All dimensions in millimeters unless otherwise noted. *CAP849604 “outer sheath” min: 85 max: 107 6 Hexagon Dimensions Gland Length ‘F’ (less entry) 36.0 Outer Sheath‘E’ INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY ADE 6F F B GE AD Features • Standard material is nickel-plated brass for superior corrosion resistance • Armour clamping and bonding with no reversible components for easy installation, minimizing error • Provides fully inspectable inner seal after installation • Flameproof diaphragm seal on inner jacket does not damage cables exhibiting “cold-flow”; weatherproof seal on outer sheath of cable • Deluge boot provides enhanced protection from water ingress • Standard neoprene seal suitable for use in operating temperatures ATEX (-60°C to 100°C), IECEx and cULus (-40°C to 100°C) • Available with metric or NPT threads • See page 10 for related accessories Gland Type Armoured with elastomeric diaphragm Cable Type Steel wire armoured, steel wire braided, steel tape armoured and braided marine shipboard Certifications and Compliances • LCIE 97 ATEX 6008X II 2 GD – Exd IIC/Exe II/ Ex tD • IECEx LCI 05.0004X – Exd IIC/Exe II/Ex tD • cULus Listed for Class I, Zone 2 AEx e II/Ex e II • cULus Marine Listed for Class I, Zone 1 AEx e II/Ex e II • NEMA 4X and IP68 • CEPEL-EX-558/05X • GOST-R POCC FR.B03126 • NEPSI N° GYJ071336U & GYJ071337U • DNV N° E-10892 • ABS approbation: n° 10-HS 577243-PDA / P1836754-X • Lloyds OPTIONS (replace last digit with option number): ORDERING EXAMPLE: 9 8 7 K1 K2 CAP96559 4 KX Gland Type Options Stainless steel (316L) Bronze Aluminum Includes locknut and fiber washer Includes locknut, fiber washer, earth tag, and shroud SELECTION TABLE Entry Thread Size ‘A’ Cable Acceptance Thread NPT Length ‘B’ Catalog No. Metric (NPT) CAP967594 15 (12.0) Min. 3.0 ⁄2" CAP967674 15 (20.2) ⁄2" CAP967694 15 (20.2) ⁄2" CAP967604 ⁄4" Gland Size 5 Metric Size M16 Metric Catalog No. CAP965594 NPT Size 3 ⁄8" 5 M20 CAP965674 1 6 M20 CAP965694 1 7 M20 CAP965604 1 7 M25 CAP965794 3 8 M25 CAP965704 8 M32 9 Inner Sheath‘D’ Hexagon Dimensions Armour (max.) 0.9 Gland Length ‘F’ (less entry) 46.0 Across Flats – Across Corners ‘G’ 20.9 Outer Sheath‘E’ Max. 7.5 Min. 6.0 Max. 12.0 3.0 7.5 6.0 12.0 0.9 46.0 – 26.4 6.5 11.0 8.5 16.0 1.25 53.0 – 26.4 15 (20.2) 9.0 14.5 12.0 21.0 1.25 59.0 – 33.0 CAP967794 15 (20.2) 9.0 14.5 12.0 21.0 1.25 59.0 – 33.0 3 ⁄4" CAP967704 15 (20.2) 12.0 19.5 16.0 27.5 1.6 74.5 – 45.1 CAP965894 1" CAP967894 15 (25.3) 12.0 19.5 16.0 27.5 1.6 74.5 – 45.1 M32 CAP965804 1" CAP967804 15 (25.3) 17.5 26.0 21.0 34.0 1.6 83.5 – 52.8 9 M40 CAP965994 1-1⁄4" CAP967994 15 (26.0) 17.5 26.0 21.0 34.0 1.6 83.5 – 52.8 10 M40 CAP965904 1-1⁄4" CAP967904 15 (26.0) 23.0 33.0 27.0 41.0 2.0 92.0 – 60.5 10 M50 CAP966094 1-1⁄2" CAP968094 16 (26.5) 23.0 33.0 27.0 41.0 2.0 92.0 – 60.5 11 M50 CAP966004 2" CAP968294 16 (27.2) 28.5 41.0 33.0 48.0 2.5 104.0 – 70.4 For larger sizes, use ADE 4F design. Please refer to previous page. All dimensions in millimeters unless otherwise noted. INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY 7 ADE 1FC F B E A G Gland Type Non-armoured barrier Features Cable Type • Standard material is nickel-plated brass for superior corrosion resistance • Provides a flameproof and weatherproof seal on the outer sheath of the cable • Provides explosionproof compound seal (denoted by red back nut) on conductors • Deluge boot provides enhanced protection from water ingress • Standard neoprene seal suitable for use in operating temperatures -60°C (-25°C UL) to 80°C • Available with metric or NPT threads • See page 10 for related accessories Non-armoured, armoured and tray cable (does not terminate the armour) Certifications and Compliances • LCIE 97 ATEX 6008X II GD – Exd IIC/Exe II/Ex tD • IECEx LCI 05.0004X Ex c e IIC/Ex c e II/Ex tD • cULus Listed for Class I, Zone 2 AEx de II/Ex de II • UL Marine Listed for Class I, Division 2, Groups A, B, C, D • NEMA 4X and IP68 • CEPEL EX-558/05X • GOST-R POCC FR.B03126 • NEPSI N° GYJ071336U & GYJ071337U • DNV N° E-10892 • ABS approbation: n° 10-HS 577243-PDA / P1836754-X • Lloyds ORDERING EXAMPLE: CAP01959 4 KX Gland Type OPTIONS (replace last digit with option number): 9 8 7 K1 K2 Options Stainless steel (316L) Bronze Aluminum* Includes locknut and fiber washer Includes locknut, fiber washer, earth tag, and shroud SELECTION TABLE Entry Thread Size ‘A’ Cable Acceptance NPT Size 3 ⁄8" NPT Catalog No. CAP011594 Thread Length ‘B’ Metric (NPT) 15 (12.0) Min. 4.0 ⁄2" CAP011674 15 (22.2) ⁄2" CAP011694 15 (22.2) ⁄2" CAP011604 ⁄4" Max. 7.5 Gland Length ‘F’ (less entry) 46.0 Across Flats - Across Corners ‘G’ 20.9 4.0 7.5 6.0 46.0 - 26.4 6.5 11.0 6.0 53.0 - 26.4 15 (22.2) 9.0 14.5 10.0 59.0 - 33.0 CAP011794 15 (22.5) 9.0 14.5 10.0 59.0 - 33.0 3 ⁄4" CAP011704 15 (22.5) 12.0 19.5 21.0 74.5 - 45.1 CAP019894 1" CAP011894 15 (27.3) 12.0 19.5 21.0 74.5 - 45.1 M32 CAP019804 1" CAP011804 15 (27.3) 17.5 26.0 42.0 83.5 - 52.8 8 M40 CAP019994 1-1⁄4" CAP011994 15 (28.0) 17.5 26.0 42.0 83.5 - 52.8 9 M40 CAP019904 1-1⁄4" CAP011904 15 (28.0) 23.0 33.0 60.0 92.0 - 60.5 9 M50 CAP019094 1-1⁄2" CAP011094 16 (28.5) 23.0 33.0 60.0 92.0 - 60.5 10 M50 CAP019004 2" CAP011004 16 (29.2) 28.5 41.0 80.0 104.0 - 70.4 10 M63 CAP019204 - - 16 28.5 41.0 80.0 - - 73.7 11 M63 CAP019294 2" CAP011294 17 (29.2) 43.0 48.0 100.0 98.0 - 70.4 12 M63 CAP019274 2" CAP011204 17 (29.2) 50.0 56.0 100.0 103.0 - 79.2 12 - - 2-1⁄2" CAP011494 42.5 50.0 56.0 100.0 103.0 - 79.2 13 M75 CAP019304 2-1⁄2" CAP011404 18 (42.5) 59.0 65.0 120.0 111.0 - 93.5 13 - - 3" CAP012504 44 59.0 65.0 120.0 111.0 - 93.5 14 M90 CAP010594 3" CAP012574 22 (44.0) 66.0 73.0 140.0 120.0 - 104.5 Metric Size M16 Metric Catalog No. CAP019594 4 M20 CAP019674 1 5 M20 CAP019694 1 6 M20 CAP019604 1 6 M25 CAP019794 3 7 M25 CAP019704 7 M32 8 Outer Sheath‘E’ 14 - - 3-1⁄2" CAP012604 45.2 66.0 73.0 140.0 120.0 - 104.5 15 M90 CAP010504 3" CAP012594 22 (44.0) 75.0 82.0 140.0 125.0 - 121.0 15 - - 3-1⁄2" CAP012694 45.2 75.0 82.0** 140.0 125.0 - 121.0 16 M110 CAP010794 4" CAP012704 22 (46.5) 85.0 92.0** 200.0 128.0 - 132.0 All dimensions in millimeters unless otherwise noted. *Aluminum not currently available with UL marine certification. **Contact Customer Service or your sales representative for amended UL marine range. 8 Hexagon Dimensions Max No. Cores 6.0 Gland Size 4 INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY ADE 6FC B F G E C D A Gland Type Armoured barrier Cable Type Features Steel wire armoured, steel wire braided, steel tape armoured, braided marine shipboard and lead sheathed (with addition of earthing washer) • Standard material is nickel-plated brass for superior corrosion resistance • Armour clamping with no reversible components for easy installation, minimizing error • Provides explosionproof compound seal (denoted by red back nut) on conductors and weatherproof seal on outer sheath of cable • Deluge boot provides enhanced protection from water ingress • Standard neoprene seal suitable for use in operating temperatures -60°C (-25°C UL) to 80°C • Available with metric or NPT threads • See page 10 for related accessories Certifications and Compliances • ATEX LCIE 97 ATEX 6008X – Exd IIC/Exe II/Ex tD/ Ex II 2 GD • IECEx LCI 05.0004X • cULus Listed for Class I, Zone 2 AEx de II/Ex de II • cULus Marine Listed for Class I, Division 1, Groups A, B, C, D • NEMA 4X and IP68 • CEPEL-EX-558/05X • GOST-R POCC FR Bo2011 • NEPSI N° GYJ071336U & GYJ071337U • ABS approbation: n° 10-HS 577243-PDA / P1836754-X • DNV N° E-10892 • Lloyds ORDERING EXAMPLE: CAP96959 4 KX Gland Type OPTIONS (replace last digit with option number): 9 8 7 K1 K2 Options Stainless steel (316L) Bronze Aluminum* Includes locknut and fiber washer Includes locknut, fiber washer, earth tag, and shroud SELECTION TABLE Entry Thread Size ‘A’ Cable Acceptance Inner Sheath and Cores Max Over Max Inner Cores Sheath Max No. ‘C’ ‘D’ of Cores NPT Size NPT Catalog No. Thread Length ‘B’ Metric (NPT) ⁄8" CAP974594 15 (12.0) 6.5 7.5 ⁄2" CAP971674 15 (20.2) 6.5 7.5 ⁄2" CAP971694 15 (20.2) 9.5 ⁄2" CAP971604 15 (20.2) ⁄4" CAP971794 3 ⁄4" CAP969894 M32 9 Hexagon Dimensions Outer Sheath ‘E’ Min. Max. Armour (Max.) Gland Length ‘F’ (less entry) 6.0 6.0 12.0 0.9 46.0 - 20.9 6.0 6.0 12.0 0.9 46.0 - 26.4 11.0 6.0 8.5 16.0 1.25 53.0 - 26.4 12.0 14.5 10.0 12.0 21.0 1.25 59.0 - 33.0 15 (20.5) 12.0 14.5 10.0 12.0 21.0 1.25 59.0 - 33.0 CAP971704 15 (20.5) 17.0 19.5 21.0 16.0 27.5 1.6 74.5 - 45.1 1" CAP971894 15 (25.3) 17.0 19.5 21.0 16.0 27.5 1.6 74.5 - 45.1 CAP969804 1" CAP971804 15 (25.3) 23.0 28.0 42.0 21.0 34.0 1.6 83.5 - 52.8 M40 CAP969994 1-1⁄4" CAP971994 15 (26.0) 23.0 28.0 42.0 21.0 34.0 1.6 83.5 - 52.8 10 M40 CAP969904 1-1⁄4" CAP971904 15 (26.0) 29.0 33.0 60.0 27.0 41.0 2.0 92.0 - 60.5 10 M50 CAP970094 1-1⁄2" CAP972094 15 (26.5) 29.0 33.0 60.0 27.0 41.0 2.0 92.0 - 60.5 11 M50 CAP970004 2" CAP972004 16 (27.2) 36.5 41.0 80.0 33.0 48.0 2.5 104.0 - 70.4 12 M63 CAP970294 2" CAP972274 17 (29.2) 43.0 48.0 100.0 40.0 56.0 2.5 108.0 - 79.2 13 M63 CAP970204 2" CAP972204 17 (29.2) 50.0 56.0 100.0 46.0 65.0 2.5 118.0 - 93.5 13 M75 CAP970394 2-1⁄2" CAP972494 18 (42.5) 50.0 56.0 100.0 46.0 65.0 2.5 118.0 - 93.5 14 M75 CAP970304 2-1⁄2" CAP972404 18 (42.5) 59.0 65.0 120.0 54.0 74.0 2.5 124.0 - 104.5 Gland Size Metric Size Metric Catalog No. 5 M16 CAP969594 3 5 M20 CAP969674 1 6 M20 CAP969694 1 7 M20 CAP969604 1 7 M25 CAP969794 3 8 M25 CAP969704 8 M32 9 Across Flats Across Corners ‘G” 14 - - 3" CAP972574 (44) 59.0 65.0 120.0 54.0 74.0 2.5 124.0 - 104.5 15 M90 CAP970594 3" CAP972594 22 (44.0) 66.0 73.0 140.0 63.0 83.0 3.15 133.0 - 121.0 15 - - 3-1⁄2" CAP972694 (45.2) 66.0 73.0 140.0 63.0 83.0 3.15 133.0 - 121.0 16 M90 CAP970504 3" CAP972504 22 (44.0) 75.0 82.0 140.0 72.0 93.0 3.15 137.0 - 132.0 16 - - 3-1⁄2" CAP972604 (45.2) 75.0 82.0** 140.0 72.0 93.0 3.15 137.0 - 132.0 17 M110 CAP970794 4" CAP972704 22 (46.5) 85.0 92.0** 200.0 85.0 107.0 3.15 142.0 - 148.5 All dimensions in millimeters unless otherwise noted. *Aluminum not currently available with UL marine certification. **Contact Customer Service or your field sales representative for amended UL marine range. INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY 9 Accessories Cooper Crouse-Hinds offers the most extensive offering of accessories to meet the needs of any installation Accessories include: • Adapters • Reducers • Unions • Stopping Plugs • Breathers / Drains • Locknuts • Washers • Earth Tags • Shrouds 10 ACCESSORIES Reference Guide General Terms Ambient Temperature – All encompassing temperature within a given area Armour – Mechanical protection usually accomplished by a metallic layer of tape, braid or served wires; normally found under the outer sheath of a cable Armoured Cable – A cable provided with a wrapping of metal, usually steel wires, flat tapes, or interlocked tapes, primarily for the purpose of mechanical protection ATEX – French term Atmosphères Explosibles (EU directive 94/9/EC) AWG – American Wire Gauge Braid Armour – A fibrous or metallic group of filaments interwoven in cylindrical form covering one or more conductors Cable Gland – A device used for the entry of cables or cords into electrical equipment providing armour clamping, sealing and/or strain relief CB – Certification Body Cold Flow – Any permanent deformation of the inner sheath of a cable due to pressure or mechanical force, without the aid of heat softening CWCMC – Continuously Welded Corrugated Metal-clad Cable DTS01 – Deluge Test developed by Shell, mainly used on offshore rigs Directive – A legislative act of the European Union EHSR – Essential Health and Safety Requirements – Requirements from new approach Directives, e.g. LVD, ATEX Hazardous – Location where fire or explosion hazards may exist due Location to the presence of flammable gases, dusts, or fibers IECEx CB – IECEx Certifying Body IECEx TR – IECEx Test Report IP – Ingress Protection ITC – Instrument tray cable ITC-HL – Instrument Tray Cable Hazardous Location LVD – Low Voltage Directive (EU directive 2006/95/EC) MC MC-HL MI MV NB PLTC Primary Seal QAR QAN Secondary Seal SWA STA SWB TC TC-ER TECK Wet Locations – Metal-clad Cable – Metal-clad Cable-Hazardous Location, for Class I, Division 1 locations – Mineral Insulated – Medium Voltage – Notified Body – Power Limited Tray Cable – A seal that isolates process fluids from an electrical system and has one side of the seal in contact with the process fluid – Quality Assurance Report – quality portion of IECEx certification – Quality Assurance Notice – quality portion of ATEX certification – A seal that is designed to prevent the passage of process fluids at the pressure it will be subjected to upon failure of the primary seal (secondary seals are required for sealing conduits and cables in Class I explosive gas atmospheres, where failure of a primary seal could allow flammable process fluids to leak into electrical equipment, with disastrous results) – Steel Wire Armour – Steel Tape Armour (also DSTA for double steel wire armour) – Steel Wire Braid – Tray Cable – Tray Cable Exposed Run – A type of metal-clad interlocked armour cable (mainly used in Canada) – Installations underground or in concrete slabs or masonry in direct contact with the earth; locations subject to saturation with water or other liquids, such as wash down areas; and in unprotected locations exposed to weather AWG to mm2 Conversion Table AWG Diameter (mm) Area (mm2) Diameter (in) AWG Diameter (mm) Area (mm2) Diameter (in) 30 28 26 24 22 20 18 16 14 12 10 8 6 0.252 0.319 0.422 0.564 0.658 0.798 0.977 1.382 1.784 2.257 2.764 3.568 4.514 0.05 0.08 0.14 0.25 0.34 0.50 0.75 1.50 2.50 4.0 6.0 10.0 16.0 0.010 0.013 0.017 0.022 0.026 0.031 0.038 0.054 0.070 0.089 0.109 0.140 0.178 4 2 1 1/0 2/0 3/0 4/0 300MCM 350MCM 500MCM 600MCM 750MCM 1000MCM 5.642 6.676 7.979 8.368 9.441 10.998 12.361 13.820 15.348 17.481 19.544 22.568 25.231 25 35 50 55 70 95 120 150 185 240 300 400 500 0.222 0.263 0.314 0.329 0.372 0.433 0.487 0.544 0.604 0.688 0.769 0.888 0.993 REFERENCE GUIDE 11 For more information: If further assistance is required, please contact an authorized Cooper Crouse-Hinds Distributor, Sales Office, or Customer Service Department. U.S. (Global Headquarters): Cooper Crouse-Hinds Wolf & Seventh North Streets Syracuse, NY 13221 (866) 764-5454 FAX: (315) 477-5179 FAX Orders Only: (866) 653-0640 crouse.customerctr@cooperindustries.com Canada: Cooper Crouse-Hinds Canada Toll Free: 800-265-0502 FAX: (800) 263-9504 FAX Orders only: (866) 653-0645 Mexico/Latin America/Caribbean: Cooper Crouse-Hinds, S.A. de C.V. 52-555-804-4000 FAX: 52-555-804-4020 mxmercadotecnia@cooperindustries.com Europe (Germany): Cooper Crouse-Hinds GmbH 49 (0) 6271 806-500 49 (0) 6271 806-476 sales.CCH.de@cooperindustries.com Middle East (Dubai): Cooper Crouse-Hinds LLC 971 4 4272500 FAX: 971 4 4298521 sales.CCH.me@cooperindustries.com Singapore: Cooper Crouse-Hinds Pte. Ltd. 65-6297-4849 FAX: 65-6297-4819 chsi-sales@cooperindustries.com China: Cooper Crouse-Hinds Pte. Ltd. 86-21-2899-3600 FAX: 86-21-2899-4055 cchsales@cooperindustries.com Korea: Cooper Crouse-Hinds Korea 82 2 538 3425 82 2 538 3505 CCHK-sales@cooperindustries.com Australia: Cooper Electrical Australia 61-2-8787-2777 FAX: 61-2-9609-2342 CEASales@cooperindustries.com India: Cooper India Pvt. Ltd. 91-124-4683888 FAX: 91-124-4683899 cchindia@cooperindustries.com www.crouse-hinds.com Cooper Crouse-Hinds is a registered trademark of Cooper Industries, Inc. © 2012 Cooper Industries, Inc. Your Authorized Cooper Crouse-Hinds Distributor is: Cooper Industries, Ltd. 600 Travis, Ste. 5800 Houston, TX 77002-1001 P: 713-209-8400 www.cooperindustries.com 5031-0212 Printed in USA