International Metallic Cable Gland Solutions Brochure:Layout 1.qxd

advertisement
International Metallic
Cable Gland Solutions
Global Cable Gland Solutions
For more than 100 years, companies have come to rely on
Cooper Crouse-Hinds for value they can trust to grow their
business. Our comprehensive offering of electrical products
meet customer application requirements in the most
demanding industrial and commercial environments
worldwide.
Our customer-first commitment to combine premium quality
and reliability with superior technical support successfully
minimizes downtime, reduces repair incidence, and improves
safety and productivity. Every product we develop and every
solution we engineer is clearly focused on lowering our
customer’s total cost of ownership.
Global termination solutions moving
power and signals in the world’s most
demanding environments
From the deserts of
Africa to the icy
waters of the North
Sea, the world turns
to Cooper CrouseHinds for its
complete gland
solutions. Our cable
glands are used in
industrial and
commercial
applications
throughout the world
engineering safety
and productivity in
the most severe
environmental
conditions.
Cooper Crouse-Hinds’ global offering provides a termination
solution for virtually every cable type used in hazardous and
industrial environments. These glands are designed for strict
adherence to global specifications meeting North American
and international codes and standards, including NEC, CEC,
ATEX, IECEx, and regional certifications.
2
GLOBAL CABLE GLAND SOLUTIONS
Cooper Crouse-Hinds cable glands are the easiest and safest
solution for your installation and maintenance needs. In any
electrical or instrumentation installation, our glands are the
reliable and safe way to move power and signals.
Global manufacturing presence and local inventory provides for
flexibility in meeting our customers’ installation and project
coordination schedules. The result is best-in-class on-time
delivery, customer satisfaction, and service. Our first-class
technical gland team is available to support product application,
technical specification, and onsite installation training on a
global basis.
Time-tested, quality cable glands
from Cooper Crouse-Hinds offer:
International Metallic Cable Gland Solutions
• Complete termination solutions for global cable applications
• Increased safety, flameproof, and explosionproof terminations for
harsh and hazardous environments
• Global certifications
• Standard in nickel-plated brass with options for stainless steel,
aluminum, and bronze
• Full line of accessories, including adapters, unions, and reducers
• Complete termination solution for
global cable applications
• Ease of cable termination providing
labor and time management
productivity
• Explosion-protected connections
contributing to safe operation in
harsh and hazardous environments
• Delivery meeting installation and
project coordination schedules
GLOBAL CABLE GLAND SOLUTIONS
3
Quick Selection Guide
International Standards
CABLE
GLAND
CABLE
TYPE
ILLUSTRATION
ADE 1F
(page 5)
ADE 4F
(page 6)
ADE 6F
(page 7)
ADE 1FC
(page 8)
ADE 6FC
(page 9)
QUICK SELECTION GUIDE
STANDARD
MATERIAL CERTIFICATION
PROTECTION
TYPE
Non-armoured
and armoured
(does not
terminate the
armour)
Nonarmoured
Nickelplated
brass
Flameproof &
Increased Safety
SWA, SWB, STA,
braided marine
shipboard and
lead sheathed
(with addition of
earthing washer)
Armoured
Nickelplated
brass
Flameproof &
Increased Safety
SWA, SWB, STA
and braided
marine shipboard
Armoured
Nickelplated
brass
Flameproof &
Increased Safety
Non-armoured
and armoured
(does not
terminate the
armour)
Nonarmoured
Barrier
Nickelplated
brass
Flameproof,
Increased Safety,
& Explosionproof
SWA, SWB, STA
and braided
marine shipboard
Armoured
Barrier
Nickelplated
brass
Flameproof,
Increased Safety,
& Explosionproof
International metallic cable glands also feature Lloyds, DNV, and ABS certifications.
4
GLAND
TYPE
ADE 1F
F
B
A
G E
Gland Type
Non-armoured
Features
Cable Type
Non-armoured and armoured
(does not terminate the armour)
Certifications and Compliances
• LCIE 97 ATEX 6008X II 2 GD – Exd IIC/Exe II/Ex tD
• IECEx LCI 05.0004X – Exd IIC/Exe II/Ex tD
• cULus Listed for Class I, Zone 2 AEx e II/Ex e II
• cULus Marine Listed for Class I, Zone 1 AEx e II
/Ex e II
• NEMA 4X and IP68
• CEPEL-EX-558/05X
• GOST-R POCC FR.B03126
• NEPSI N° GYJ071336U & GYJ071337U
• DNV N° E-10892
• ABS approbation:
n° 10-HS 577243-PDA / P1836754-X
• Lloyds
• Standard material is nickel-plated brass for superior corrosion
resistance
• Provides a flameproof and weatherproof seal on the outer sheath of the
cable
• Standard neoprene seal suitable for use in operating temperatures ATEX
(-60°C to 100°C), IECEx and cULus (-40°C to 100°C)
• Available with optional silicone seal for extreme temperatures
• Available with metric or NPT threads
• See page 10 for related accessories
OPTIONS (replace last digit with option number):
ORDERING EXAMPLE:
9
8
7
5
Stainless steel (316L)
Bronze
Aluminum
Silicone sealing ring with temperature range of
-70°C to 220°C
K1 Includes locknut and fiber washer
K2 Includes locknut, fiber washer, earth tag, and
shroud
CAP81640 4 KX
Gland Type
Options
SELECTION TABLE
Entry Thread Size ‘A’
Cable Acceptance
Hexagon Dimensions
NPT
Size
NPT
Catalog No.
Thread
Length ‘B’
Metric (NPT)
⁄4"
CAP818404
15 (12.0)
4.0
8.0
20.0
–
16.5
⁄8"
CAP818594
15 (12.0)
4.0
8.5
20.0
–
20.9
⁄8"
CAP818504
15 (12.0)
6.0
12.0
22.0
–
20.9
⁄2"
CAP818674
15 (20.2)
4.0
8.5
20.0
–
26.4
⁄2"
CAP818694
15 (20.2)
6.0
12.0
22.0
–
26.4
⁄2"
CAP818604
15 (20.2)
8.5
16.0
25.0
–
26.4
⁄4"
CAP818774
15 (20.2)
6.0
12.0
22.0
–
33.0
⁄4"
CAP818794
15 (20.2)
8.5
16.0
25.0
–
33.0
3
⁄4"
CAP818704
15 (20.2)
12.0
21.0
27.0
–
33.0
CAP816894
1"
CAP818894
15 (25.3)
12.0
21.0
27.0
–
39.6
M32
CAP816804
1"
CAP818804
15 (25.3)
16.0
27.5
34.0
–
45.1
8
M40
CAP816994
1-1⁄4"
CAP818994
15 (26.0)
16.0
27.5
34.0
–
48.4
9
M40
CAP816904
1-1⁄4"
CAP818904
15 (26.0)
21.0
34.0
36.0
–
52.8
9
M50
CAP817094
1-1⁄2"
CAP819094
15 (26.5)
21.0
34.0
36.0
–
60.5
10
M50
CAP817004
1-1⁄2"
CAP819004
15 (26.5)
27.0
41.0
39.0
–
60.5
11
M63
CAP817294
2"
CAP819294
17 (27.2)
33.0
48.0
41.0
–
73.7
12
M63
CAP817204
2"
CAP819204
17 (27.2)
40.0
56.0
43.0
–
79.2
12
M75
CAP817394
2-1⁄2"
CAP819494
18 (40.5)
40.0
56.0
43.0
–
88.0
13
M75
CAP817304
2-1⁄2"
CAP819404
18 (40.5)
47.0
65.0
49.0
–
93.5
14
M90
CAP817594
3"
CAP819594
22 (42.0)
54.0
74.0
56.0
–
104.5
15
M90
CAP817504
3"
CAP819504
22 (42.0)
63.0
78.0
61.0
–
121.0
16
M110
CAP817794
3-1⁄2"
CAP819604
22 (43.2)
72.0
92.0
62.0
–
132.0
Gland
Size
Metric
Size
Metric
Catalog No.
4
M12
CAP816404
1
4
M16
CAP816594
3
5
M16
CAP816504
3
4
M20
CAP816674
1
5
M20
CAP816694
1
6
M20
CAP816604
1
5
M25
CAP816774
3
6
M25
CAP816794
3
7
M25
CAP816704
7
M32
8
Max.
Gland
Length ‘F’
(less entry)
Across
Flats
Across
Corners ‘G’
Outer Sheath ‘E’
Min.
All dimensions in millimeters unless otherwise noted.
INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY
5
ADE 4F
F
B
G E
A D
Gland Type
Armoured
Features
Cable Type
Steel wire armoured, steel wire braided, steel tape
armoured, braided marine shipboard and lead
sheathed (with addition of earthing washer)
Certifications and Compliances
• LCIE 97 ATEX 6008X II 2 GD – Exd IIC/Exe II/Ex
tD
• IECEx LCI 05.0004X – Exd IIC/Exe II/Ex tD
• cULus Listed for Class I, Zone 2 AEx e II/Ex e II
• cULus Marine Listed for Class I, Zone 1 AEx e II/
Ex e II
• NEMA 4X and IP68
• CEPEL-EX-558/05X
• GOST-R POCC FR.B03126
• NEPSI N° GYJ071336U & GYJ071337U
• DNV N° E-10892
• ABS approbation:
n° 10-HS 577243-PDA / P1836754-X
• Lloyds
• Standard material is nickel-plated brass for superior corrosion resistance
• Armour clamping and bonding with no reversible components for easy
installation, minimizing error
• Provides flameproof seal on inner jacket and weatherproof seal on
outer sheath of cable
• Optional earthing washer for use with lead sheathed cable
• Standard neoprene seal suitable for use in operating temperatures ATEX
(-60°C to 100°C), IECEx and cULus (-40°C to 100°C)
• Available with optional silicone seal for extreme temperatures
• Available with metric or NPT threads
• See page 10 for related accessories
OPTIONS (replace last digit with option number):
ORDERING EXAMPLE:
9
8
7
5
Stainless steel (316L)
Bronze
Aluminum
Silicone sealing ring with temperature range of
-70°C to 220°C
K1 Includes locknut and fiber washer
K2 Includes locknut, fiber washer, earth tag, and
shroud
CAP84640 4 KX
Gland Type
Options
SELECTION TABLE
Entry Thread Size ‘A’
Cable Acceptance
Thread
NPT
Length ‘B’
Catalog No. Metric (NPT)
CAP848404 15 (12.0)
Min.
4.0
⁄8"
CAP848594
15 (12.0)
⁄8"
CAP848504
15 (12.0)
⁄2"
CAP848674
⁄2"
Gland
Size
5
Metric
Size
M12
Metric
Catalog No.
CAP846404
NPT
Size
1
⁄4"
5
M16
CAP846594
3
6
M16
CAP846504
3
5
M20
CAP846674
1
6
M20
CAP846694
1
7
M20
CAP846604
1
6
M25
CAP846774
3
7
M25
CAP846794
3
8
M25
CAP846704
8
M32
9
Inner Sheath‘D’
Armour
(max.)
0.9
Across
Flats
–
Across
Corners ‘G’
20.9
Max.
8.0
Min.
6.0
Max.
12.0
4.0
8.5
6.0
12.0
0.9
36.0
–
20.9
6.0
12.0
8.5
16.0
1.25
42.0
–
26.4
15 (20.2)
4.0
8.5
6.0
12.0
0.9
36.0
–
26.4
CAP848694
15 (20.2)
6.0
12.0
8.5
16.0
1.25
42.0
–
26.4
⁄2"
CAP848604
15 (20.2)
8.5
16.0
12.0
21.0
1.25
46.0
–
33.0
⁄4"
CAP848774
15 (20.2)
6.0
12.0
8.5
16.0
1.25
42.0
–
33.0
⁄4"
CAP848794
15 (20.2)
8.5
16.0
12.0
21.0
1.25
46.0
–
33.0
3
⁄4"
CAP848704
15 (20.2)
12.0
20.5
16.0
27.5
1.6
56.0
–
45.1
CAP846894
1"
CAP848894
15 (25.3)
12.0
21.0
16.0
27.5
1.6
56.0
–
45.1
M32
CAP846804
1"
CAP848804
15 (25.3)
16.0
27.5
21.0
34.0
1.6
63.0
–
52.8
9
M40
CAP846994
1-1⁄4"
CAP848994
15 (26.0)
16.0
27.5
21.0
34.0
1.6
63.0
–
52.8
10
M40
CAP846904
1-1⁄4"
CAP848904
15 (26.0)
21.0
34.0
27.0
41.0
2.0
68.0
–
60.5
10
M50
CAP847094
1-1⁄2"
CAP849094
16 (26.5)
21.0
34.0
27.0
41.0
2.0
68.0
–
60.5
11
M50
CAP847004
1-1⁄2"
CAP849004
16 (26.5)
27.0
41.0
33.0
48.0
2.5
74.0
–
70.4
12
M63
CAP847294
2"
CAP849294
17 (27.2)
27.0
41.0
33.0
48.0
2.5
77.0
–
79.2
13
M63
CAP847204
2"
CAP849204
17 (27.2)
33.0
48.0
40.0
56.0
2.5
85.0
–
93.5
13
M75
CAP847394
2-1⁄2"
CAP849494
18 (40.5)
40.0
56.0
47.0
65.0
2.5
85.0
–
93.5
14
M75
CAP847304
2-1⁄2"
CAP849404
18 (40.5)
47.0
65.0
54.0
74.0
2.5
92.0
–
104.5
15
M90
CAP847594
3"
CAP849594
22 (42.0)
54.0
74.0
63.0
83.0
3.15
104.0
–
121.0
16
M90
CAP847504
3"
CAP849504
22 (42.0)
63.0
82.0
72.0
93.0
3.15
108.0
–
132.0
16
M90
CAP847574
3-1⁄2"
CAP849604
N/A (43.2)
63.0
82.0
72.0*
93.0*
3.15
108.0
–
132.0
17
M110
CAP847794
4"
CAP849704
22 (44.5)
72.0
92.0
85.0
107.0
3.15
115.0
–
148.5
All dimensions in millimeters unless otherwise noted.
*CAP849604 “outer sheath” min: 85 max: 107
6
Hexagon Dimensions
Gland
Length ‘F’
(less entry)
36.0
Outer Sheath‘E’
INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY
ADE 6F
F
B
GE
AD
Features
• Standard material is nickel-plated brass for superior corrosion
resistance
• Armour clamping and bonding with no reversible components for easy
installation, minimizing error
• Provides fully inspectable inner seal after installation
• Flameproof diaphragm seal on inner jacket does not damage cables
exhibiting “cold-flow”; weatherproof seal on outer sheath of cable
• Deluge boot provides enhanced protection from water ingress
• Standard neoprene seal suitable for use in operating temperatures ATEX
(-60°C to 100°C), IECEx and cULus (-40°C to 100°C)
• Available with metric or NPT threads
• See page 10 for related accessories
Gland Type
Armoured with elastomeric diaphragm
Cable Type
Steel wire armoured, steel wire braided, steel
tape armoured and braided marine shipboard
Certifications and Compliances
• LCIE 97 ATEX 6008X II 2 GD – Exd IIC/Exe II/
Ex tD
• IECEx LCI 05.0004X – Exd IIC/Exe II/Ex tD
• cULus Listed for Class I, Zone 2 AEx e II/Ex e II
• cULus Marine Listed for Class I, Zone 1
AEx e II/Ex e II
• NEMA 4X and IP68
• CEPEL-EX-558/05X
• GOST-R POCC FR.B03126
• NEPSI N° GYJ071336U & GYJ071337U
• DNV N° E-10892
• ABS approbation:
n° 10-HS 577243-PDA / P1836754-X
• Lloyds
OPTIONS (replace last digit with option number):
ORDERING EXAMPLE:
9
8
7
K1
K2
CAP96559 4 KX
Gland Type
Options
Stainless steel (316L)
Bronze
Aluminum
Includes locknut and fiber washer
Includes locknut, fiber washer, earth tag, and
shroud
SELECTION TABLE
Entry Thread Size ‘A’
Cable Acceptance
Thread
NPT
Length ‘B’
Catalog No. Metric (NPT)
CAP967594 15 (12.0)
Min.
3.0
⁄2"
CAP967674
15 (20.2)
⁄2"
CAP967694
15 (20.2)
⁄2"
CAP967604
⁄4"
Gland
Size
5
Metric
Size
M16
Metric
Catalog No.
CAP965594
NPT
Size
3
⁄8"
5
M20
CAP965674
1
6
M20
CAP965694
1
7
M20
CAP965604
1
7
M25
CAP965794
3
8
M25
CAP965704
8
M32
9
Inner Sheath‘D’
Hexagon Dimensions
Armour
(max.)
0.9
Gland
Length ‘F’
(less entry)
46.0
Across
Flats
–
Across
Corners ‘G’
20.9
Outer Sheath‘E’
Max.
7.5
Min.
6.0
Max.
12.0
3.0
7.5
6.0
12.0
0.9
46.0
–
26.4
6.5
11.0
8.5
16.0
1.25
53.0
–
26.4
15 (20.2)
9.0
14.5
12.0
21.0
1.25
59.0
–
33.0
CAP967794
15 (20.2)
9.0
14.5
12.0
21.0
1.25
59.0
–
33.0
3
⁄4"
CAP967704
15 (20.2)
12.0
19.5
16.0
27.5
1.6
74.5
–
45.1
CAP965894
1"
CAP967894
15 (25.3)
12.0
19.5
16.0
27.5
1.6
74.5
–
45.1
M32
CAP965804
1"
CAP967804
15 (25.3)
17.5
26.0
21.0
34.0
1.6
83.5
–
52.8
9
M40
CAP965994
1-1⁄4"
CAP967994
15 (26.0)
17.5
26.0
21.0
34.0
1.6
83.5
–
52.8
10
M40
CAP965904
1-1⁄4"
CAP967904
15 (26.0)
23.0
33.0
27.0
41.0
2.0
92.0
–
60.5
10
M50
CAP966094
1-1⁄2"
CAP968094
16 (26.5)
23.0
33.0
27.0
41.0
2.0
92.0
–
60.5
11
M50
CAP966004
2"
CAP968294
16 (27.2)
28.5
41.0
33.0
48.0
2.5
104.0
–
70.4
For larger sizes, use ADE 4F design. Please refer to previous page.
All dimensions in millimeters unless otherwise noted.
INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY
7
ADE 1FC
F
B
E
A
G
Gland Type
Non-armoured barrier
Features
Cable Type
• Standard material is nickel-plated brass for superior corrosion
resistance
• Provides a flameproof and weatherproof seal on the outer sheath of the
cable
• Provides explosionproof compound seal (denoted by red back nut) on
conductors
• Deluge boot provides enhanced protection from water ingress
• Standard neoprene seal suitable for use in operating temperatures
-60°C (-25°C UL) to 80°C
• Available with metric or NPT threads
• See page 10 for related accessories
Non-armoured, armoured and tray cable
(does not terminate the armour)
Certifications and Compliances
• LCIE 97 ATEX 6008X II GD – Exd IIC/Exe II/Ex tD
• IECEx LCI 05.0004X Ex c e IIC/Ex c e II/Ex tD
• cULus Listed for Class I, Zone 2 AEx de II/Ex de II
• UL Marine Listed for Class I, Division 2, Groups
A, B, C, D
• NEMA 4X and IP68
• CEPEL EX-558/05X
• GOST-R POCC FR.B03126
• NEPSI N° GYJ071336U & GYJ071337U
• DNV N° E-10892
• ABS approbation:
n° 10-HS 577243-PDA / P1836754-X
• Lloyds
ORDERING EXAMPLE:
CAP01959 4 KX
Gland Type
OPTIONS (replace last digit with option number):
9
8
7
K1
K2
Options
Stainless steel (316L)
Bronze
Aluminum*
Includes locknut and fiber washer
Includes locknut, fiber washer, earth tag, and
shroud
SELECTION TABLE
Entry Thread Size ‘A’
Cable Acceptance
NPT
Size
3
⁄8"
NPT
Catalog No.
CAP011594
Thread
Length ‘B’
Metric (NPT)
15 (12.0)
Min.
4.0
⁄2"
CAP011674
15 (22.2)
⁄2"
CAP011694
15 (22.2)
⁄2"
CAP011604
⁄4"
Max.
7.5
Gland
Length ‘F’
(less entry)
46.0
Across
Flats
-
Across
Corners ‘G’
20.9
4.0
7.5
6.0
46.0
-
26.4
6.5
11.0
6.0
53.0
-
26.4
15 (22.2)
9.0
14.5
10.0
59.0
-
33.0
CAP011794
15 (22.5)
9.0
14.5
10.0
59.0
-
33.0
3
⁄4"
CAP011704
15 (22.5)
12.0
19.5
21.0
74.5
-
45.1
CAP019894
1"
CAP011894
15 (27.3)
12.0
19.5
21.0
74.5
-
45.1
M32
CAP019804
1"
CAP011804
15 (27.3)
17.5
26.0
42.0
83.5
-
52.8
8
M40
CAP019994
1-1⁄4"
CAP011994
15 (28.0)
17.5
26.0
42.0
83.5
-
52.8
9
M40
CAP019904
1-1⁄4"
CAP011904
15 (28.0)
23.0
33.0
60.0
92.0
-
60.5
9
M50
CAP019094
1-1⁄2"
CAP011094
16 (28.5)
23.0
33.0
60.0
92.0
-
60.5
10
M50
CAP019004
2"
CAP011004
16 (29.2)
28.5
41.0
80.0
104.0
-
70.4
10
M63
CAP019204
-
-
16
28.5
41.0
80.0
-
-
73.7
11
M63
CAP019294
2"
CAP011294
17 (29.2)
43.0
48.0
100.0
98.0
-
70.4
12
M63
CAP019274
2"
CAP011204
17 (29.2)
50.0
56.0
100.0
103.0
-
79.2
12
-
-
2-1⁄2"
CAP011494
42.5
50.0
56.0
100.0
103.0
-
79.2
13
M75
CAP019304
2-1⁄2"
CAP011404
18 (42.5)
59.0
65.0
120.0
111.0
-
93.5
13
-
-
3"
CAP012504
44
59.0
65.0
120.0
111.0
-
93.5
14
M90
CAP010594
3"
CAP012574
22 (44.0)
66.0
73.0
140.0
120.0
-
104.5
Metric
Size
M16
Metric
Catalog No.
CAP019594
4
M20
CAP019674
1
5
M20
CAP019694
1
6
M20
CAP019604
1
6
M25
CAP019794
3
7
M25
CAP019704
7
M32
8
Outer Sheath‘E’
14
-
-
3-1⁄2"
CAP012604
45.2
66.0
73.0
140.0
120.0
-
104.5
15
M90
CAP010504
3"
CAP012594
22 (44.0)
75.0
82.0
140.0
125.0
-
121.0
15
-
-
3-1⁄2"
CAP012694
45.2
75.0
82.0**
140.0
125.0
-
121.0
16
M110
CAP010794
4"
CAP012704
22 (46.5)
85.0
92.0**
200.0
128.0
-
132.0
All dimensions in millimeters unless otherwise noted.
*Aluminum not currently available with UL marine certification.
**Contact Customer Service or your sales representative for amended UL marine range.
8
Hexagon Dimensions
Max
No.
Cores
6.0
Gland
Size
4
INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY
ADE 6FC
B
F
G E
C D A
Gland Type
Armoured barrier
Cable Type
Features
Steel wire armoured, steel wire braided, steel tape
armoured, braided marine shipboard and lead
sheathed (with addition of earthing washer)
• Standard material is nickel-plated brass for superior corrosion
resistance
• Armour clamping with no reversible components for easy installation,
minimizing error
• Provides explosionproof compound seal (denoted by red back nut) on
conductors and weatherproof seal on outer sheath of cable
• Deluge boot provides enhanced protection from water ingress
• Standard neoprene seal suitable for use in operating temperatures
-60°C (-25°C UL) to 80°C
• Available with metric or NPT threads
• See page 10 for related accessories
Certifications and Compliances
• ATEX LCIE 97 ATEX 6008X – Exd IIC/Exe II/Ex tD/
Ex II 2 GD
• IECEx LCI 05.0004X
• cULus Listed for Class I, Zone 2 AEx de II/Ex de II
• cULus Marine Listed for Class I, Division 1,
Groups A, B, C, D
• NEMA 4X and IP68
• CEPEL-EX-558/05X
• GOST-R POCC FR Bo2011
• NEPSI N° GYJ071336U & GYJ071337U
• ABS approbation:
n° 10-HS 577243-PDA / P1836754-X
• DNV N° E-10892
• Lloyds
ORDERING EXAMPLE:
CAP96959 4 KX
Gland Type
OPTIONS (replace last digit with option number):
9
8
7
K1
K2
Options
Stainless steel (316L)
Bronze
Aluminum*
Includes locknut and fiber washer
Includes locknut, fiber washer, earth tag, and
shroud
SELECTION TABLE
Entry Thread Size ‘A’
Cable Acceptance
Inner Sheath and Cores
Max Over Max Inner
Cores
Sheath
Max No.
‘C’
‘D’
of Cores
NPT
Size
NPT
Catalog No.
Thread
Length ‘B’
Metric
(NPT)
⁄8"
CAP974594
15 (12.0)
6.5
7.5
⁄2"
CAP971674
15 (20.2)
6.5
7.5
⁄2"
CAP971694
15 (20.2)
9.5
⁄2"
CAP971604
15 (20.2)
⁄4"
CAP971794
3
⁄4"
CAP969894
M32
9
Hexagon Dimensions
Outer Sheath ‘E’
Min.
Max.
Armour
(Max.)
Gland
Length
‘F’
(less entry)
6.0
6.0
12.0
0.9
46.0
-
20.9
6.0
6.0
12.0
0.9
46.0
-
26.4
11.0
6.0
8.5
16.0
1.25
53.0
-
26.4
12.0
14.5
10.0
12.0
21.0
1.25
59.0
-
33.0
15 (20.5)
12.0
14.5
10.0
12.0
21.0
1.25
59.0
-
33.0
CAP971704
15 (20.5)
17.0
19.5
21.0
16.0
27.5
1.6
74.5
-
45.1
1"
CAP971894
15 (25.3)
17.0
19.5
21.0
16.0
27.5
1.6
74.5
-
45.1
CAP969804
1"
CAP971804
15 (25.3)
23.0
28.0
42.0
21.0
34.0
1.6
83.5
-
52.8
M40
CAP969994
1-1⁄4"
CAP971994
15 (26.0)
23.0
28.0
42.0
21.0
34.0
1.6
83.5
-
52.8
10
M40
CAP969904
1-1⁄4"
CAP971904
15 (26.0)
29.0
33.0
60.0
27.0
41.0
2.0
92.0
-
60.5
10
M50
CAP970094
1-1⁄2"
CAP972094
15 (26.5)
29.0
33.0
60.0
27.0
41.0
2.0
92.0
-
60.5
11
M50
CAP970004
2"
CAP972004
16 (27.2)
36.5
41.0
80.0
33.0
48.0
2.5
104.0
-
70.4
12
M63
CAP970294
2"
CAP972274
17 (29.2)
43.0
48.0
100.0
40.0
56.0
2.5
108.0
-
79.2
13
M63
CAP970204
2"
CAP972204
17 (29.2)
50.0
56.0
100.0
46.0
65.0
2.5
118.0
-
93.5
13
M75
CAP970394
2-1⁄2"
CAP972494
18 (42.5)
50.0
56.0
100.0
46.0
65.0
2.5
118.0
-
93.5
14
M75
CAP970304
2-1⁄2"
CAP972404
18 (42.5)
59.0
65.0
120.0
54.0
74.0
2.5
124.0
-
104.5
Gland
Size
Metric
Size
Metric
Catalog No.
5
M16
CAP969594
3
5
M20
CAP969674
1
6
M20
CAP969694
1
7
M20
CAP969604
1
7
M25
CAP969794
3
8
M25
CAP969704
8
M32
9
Across
Flats
Across
Corners ‘G”
14
-
-
3"
CAP972574
(44)
59.0
65.0
120.0
54.0
74.0
2.5
124.0
-
104.5
15
M90
CAP970594
3"
CAP972594
22 (44.0)
66.0
73.0
140.0
63.0
83.0
3.15
133.0
-
121.0
15
-
-
3-1⁄2"
CAP972694
(45.2)
66.0
73.0
140.0
63.0
83.0
3.15
133.0
-
121.0
16
M90
CAP970504
3"
CAP972504
22 (44.0)
75.0
82.0
140.0
72.0
93.0
3.15
137.0
-
132.0
16
-
-
3-1⁄2"
CAP972604
(45.2)
75.0
82.0**
140.0
72.0
93.0
3.15
137.0
-
132.0
17
M110
CAP970794
4"
CAP972704
22 (46.5)
85.0
92.0**
200.0
85.0
107.0
3.15
142.0
-
148.5
All dimensions in millimeters unless otherwise noted.
*Aluminum not currently available with UL marine certification.
**Contact Customer Service or your field sales representative for amended UL marine range.
INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY
9
Accessories
Cooper Crouse-Hinds offers the most extensive offering of accessories to meet
the needs of any installation
Accessories include:
• Adapters
• Reducers
• Unions
• Stopping Plugs
• Breathers / Drains
• Locknuts
• Washers
• Earth Tags
• Shrouds
10
ACCESSORIES
Reference Guide
General Terms
Ambient Temperature – All encompassing temperature within a given area
Armour
– Mechanical protection usually accomplished by a metallic
layer of tape, braid or served wires; normally found under
the outer sheath of a cable
Armoured Cable
– A cable provided with a wrapping of metal, usually steel
wires, flat tapes, or interlocked tapes, primarily for the
purpose of mechanical protection
ATEX
– French term Atmosphères Explosibles (EU directive
94/9/EC)
AWG
– American Wire Gauge
Braid Armour
– A fibrous or metallic group of filaments interwoven in
cylindrical form covering one or more conductors
Cable Gland
– A device used for the entry of cables or cords into electrical
equipment providing armour clamping, sealing and/or strain
relief
CB
– Certification Body
Cold Flow
– Any permanent deformation of the inner sheath of a cable
due to pressure or mechanical force, without the aid of heat
softening
CWCMC
– Continuously Welded Corrugated Metal-clad Cable
DTS01
– Deluge Test developed by Shell, mainly used on offshore
rigs
Directive
– A legislative act of the European Union
EHSR
– Essential Health and Safety Requirements – Requirements
from new approach Directives, e.g. LVD, ATEX
Hazardous
– Location where fire or explosion hazards may exist due
Location
to the presence of flammable gases, dusts, or fibers
IECEx CB
– IECEx Certifying Body
IECEx TR
– IECEx Test Report
IP
– Ingress Protection
ITC
– Instrument tray cable
ITC-HL
– Instrument Tray Cable Hazardous Location
LVD
– Low Voltage Directive (EU directive 2006/95/EC)
MC
MC-HL
MI
MV
NB
PLTC
Primary Seal
QAR
QAN
Secondary Seal
SWA
STA
SWB
TC
TC-ER
TECK
Wet Locations
– Metal-clad Cable
– Metal-clad Cable-Hazardous Location, for Class I, Division
1 locations
– Mineral Insulated
– Medium Voltage
– Notified Body
– Power Limited Tray Cable
– A seal that isolates process fluids from an electrical
system and has one side of the seal in contact with the
process fluid
– Quality Assurance Report – quality portion of IECEx
certification
– Quality Assurance Notice – quality portion of ATEX
certification
– A seal that is designed to prevent the passage of process
fluids at the pressure it will be subjected to upon failure of
the primary seal (secondary seals are required for sealing
conduits and cables in Class I explosive gas atmospheres,
where failure of a primary seal could allow flammable
process fluids to leak into electrical equipment, with
disastrous results)
– Steel Wire Armour
– Steel Tape Armour (also DSTA for double steel wire armour)
– Steel Wire Braid
– Tray Cable
– Tray Cable Exposed Run
– A type of metal-clad interlocked armour cable (mainly
used in Canada)
– Installations underground or in concrete slabs or masonry
in direct contact with the earth; locations subject to
saturation with water or other liquids, such as wash down
areas; and in unprotected locations exposed to weather
AWG to mm2 Conversion Table
AWG
Diameter (mm)
Area (mm2)
Diameter (in)
AWG
Diameter (mm)
Area (mm2)
Diameter (in)
30
28
26
24
22
20
18
16
14
12
10
8
6
0.252
0.319
0.422
0.564
0.658
0.798
0.977
1.382
1.784
2.257
2.764
3.568
4.514
0.05
0.08
0.14
0.25
0.34
0.50
0.75
1.50
2.50
4.0
6.0
10.0
16.0
0.010
0.013
0.017
0.022
0.026
0.031
0.038
0.054
0.070
0.089
0.109
0.140
0.178
4
2
1
1/0
2/0
3/0
4/0
300MCM
350MCM
500MCM
600MCM
750MCM
1000MCM
5.642
6.676
7.979
8.368
9.441
10.998
12.361
13.820
15.348
17.481
19.544
22.568
25.231
25
35
50
55
70
95
120
150
185
240
300
400
500
0.222
0.263
0.314
0.329
0.372
0.433
0.487
0.544
0.604
0.688
0.769
0.888
0.993
REFERENCE GUIDE
11
For more information:
If further assistance is required, please contact an authorized Cooper Crouse-Hinds Distributor,
Sales Office, or Customer Service Department.
U.S. (Global Headquarters):
Cooper Crouse-Hinds
Wolf & Seventh North Streets
Syracuse, NY 13221
(866) 764-5454
FAX: (315) 477-5179
FAX Orders Only: (866) 653-0640
crouse.customerctr@cooperindustries.com
Canada:
Cooper Crouse-Hinds Canada
Toll Free: 800-265-0502
FAX: (800) 263-9504
FAX Orders only: (866) 653-0645
Mexico/Latin America/Caribbean:
Cooper Crouse-Hinds, S.A. de C.V.
52-555-804-4000
FAX: 52-555-804-4020
mxmercadotecnia@cooperindustries.com
Europe (Germany):
Cooper Crouse-Hinds GmbH
49 (0) 6271 806-500
49 (0) 6271 806-476
sales.CCH.de@cooperindustries.com
Middle East (Dubai):
Cooper Crouse-Hinds LLC
971 4 4272500
FAX: 971 4 4298521
sales.CCH.me@cooperindustries.com
Singapore:
Cooper Crouse-Hinds Pte. Ltd.
65-6297-4849
FAX: 65-6297-4819
chsi-sales@cooperindustries.com
China:
Cooper Crouse-Hinds Pte. Ltd.
86-21-2899-3600
FAX: 86-21-2899-4055
cchsales@cooperindustries.com
Korea:
Cooper Crouse-Hinds Korea
82 2 538 3425
82 2 538 3505
CCHK-sales@cooperindustries.com
Australia:
Cooper Electrical Australia
61-2-8787-2777
FAX: 61-2-9609-2342
CEASales@cooperindustries.com
India:
Cooper India Pvt. Ltd.
91-124-4683888
FAX: 91-124-4683899
cchindia@cooperindustries.com
www.crouse-hinds.com
Cooper Crouse-Hinds is a registered trademark of Cooper Industries, Inc.
© 2012 Cooper Industries, Inc.
Your Authorized Cooper Crouse-Hinds Distributor is:
Cooper Industries, Ltd.
600 Travis, Ste. 5800
Houston, TX 77002-1001
P: 713-209-8400
www.cooperindustries.com
5031-0212
Printed in USA
Download