Data Sheet
Edgewise Series
010.D.201.07
Analog Meters
Edgewise with
Moving-Coil Movement
P 48 PrS
P 72 PrS
P 96 PrS
P 144 PrS
Application
Measuring Ranges
The edgewise moving - coil panel meters P 48/72/96/144 PrS with a
curved dial are used for measurement of DC currents and voltages. The
edgewise case styles provide a high ratio of scale length to panel area.
These instruments are suitable to be mounted in switchboards, control
panels, machine tool consoles and mosaic panels.
For mains use
DC current
'
50 mA
60 mA
100 mA
150 mA
250 mA
400 mA
600 mA
1 mA
1.5 mA
2.5 mA
4 mA
5 mA
6 mA
10 mA
15 mA
20 mA
25 mA
40 mA
60 mA
100 mA
150 mA
250 mA
400 mA
600 mA
1A
1.5 A
2.5 A
4A
6A
10 A
15 A
25 A
40 A
60 A
Movements
Self–shielding moving - coil movements with core - type magnet
(P 72/96/144 PrS) resp. swivel coil (P 48 PrS), pivot suspended. Spring
loaded jewel bearings for vibration and shock resistance.
Mechanical Data
case details
material of case
material of window
colour of bezel
position of use
panel fixing
mounting
terminals
voltmeters and
ammeters 3 A
ammeters >3 A
voltmeters ≥300 V
dimensions (in mm)
bezel
case
depth
panel cutout
panel thickness
weight approx.
edgewise case suitable to be mounted
in control / switchgear panels, machine tool
consoles or mosaic panels, stackable
pressed steel (P 72/96 PrS)
thermoplastics (P 48/144 PrS)
glass '
black (similar to RAL 9005) '
vertical ±5° '
screw clamps
stackable next to each other (except P 144 PrS)
hexagon studs, M3 screws and
wire clamps C6 (P 72/96 PrS),
connector blades 6.3 x 0.8 (P 48/144 PrS)
hexagon studs, M5 screws and
wire clamps C10
(P 72/96 PrS)
connector blades 6.3 x 0.8 for protective wire
P 48 PrS P 72 PrS P 96 PrS P 144 PrS
48 x 24
72 x 36
96 x 48
144 x 72
43 x 17
66 x 32
91 x 43
137 x 67
75
94
107
192
68+0.7
92+0.8
138+1.0
45+0.6
x 22.2+0.3 x 33+0.6 x 45+0.6 x 68+0.7
1 ... 25
1 ... 25
1 ... 12
40
0.08 kg
0.2 kg
0.45 kg
0.6 kg
Electrical Data
internal resistance 1) / voltage drop approx.
P 48 PrS P 72 PrS P 96 PrS P 144 PrS
operating
voltage '
1000 W
1040 W
1000 W
835 W
500 W
310 W
210 W
32 mV
46 mV
46 mV
46 mV
46 mV
46 mV
46 mV
46 mV
46 mV
46 mV
46 mV
46 mV
46 mV
46 mV
46 mV
46 mV
46 mV
46 mV
–
–
–
–
–
–
–
–
–
6500 W
5500 W
4900 W
3600 W
2200 W
1300 W
250 W
48 W
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
–
–
6500 W
5500 W
4900 W
3600 W
2200 W
1300 W
250 W
48 W
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
–
P 48 PrS
300 V
P 72 PrS
300 V
P 96 PrS
300 V
4600 W
4400 W
2800 W
2200 W
740 W
630 W
260 W
48 W
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
P 144 PrS
600 V
for use with external shunt
60 mV
150 mV
sensitivity*) 1000 W/V
a total lead resistance of 0.05 W is considered in the calibration of the
indicator for connecting leads 1 m, 2 x 0.75 mm2 '
DC voltage >5V
P 48 PrS
P 72/96 PrS
P 144 PrS
measuring unit
DC voltages or DC currents
overload capacity (acc. to DIN EN 60 051 - 1)
continuously
1.2 times rated voltage / current
5 s max.
voltmeters
2 times rated voltage
ammeters
10 times rated current
measurement category CAT III
operating voltage
refer to Measuring Ranges
pollution level
2
enclosure code
IP 52 case front side '
IP 00 for terminals without protection against
accidental contact
IP 20 for terminals protected against
accidental contact
sensitivity1) '
1000 W/V
1000 W/V
1000 W/V
50 V
100 V
100 V
100 V
300 V
600 V
600 V
600 V
' also refer to ”Options”
*)
6 V, 10 V, 15 V, 25 V, 40 V,
operating voltage
50 V
60 V, 100 V,
operating voltage '
300 V
150 V, 250 V,
operating voltage '
300 V
400 V, 500 V, 600 V
operating voltage '
600 V
'
the resistance values are limited to a tolerance of ±20%
Data Sheet
Edgewise Series
010.D.201.07
Analog Meters
Edgewise with
Moving-Coil Movement
Not for mains use
DC voltage ≤5V
P 48 PrS
Environmental
P 72/96 PrS
P 144 PrS
climatic suitability
40 mV
–
3300 W/V
sensitivity1) '
operating voltage '
–
300 V
60 mV, 100 mV, 150 mV, 250 mV, 400 mV, 600 mV,
1 V, 1,5 V, 2,5 V, 4 V
1000 W/V
1000 W/V
sensitivity1) '
operating voltage '
50 V
50 V
'
2000 W/V
600 V
1000 W/V
100 V
for use on transducer (”live zero”)
4 ... 20 mA
0/4 ... 20 mA
operating
voltage '
mechanically suppressed zero,
without zero adjustment,
voltage drop approx. 46 mV (P 48 PrS)
approx. 60 mV (P 72/96/144 PrS)
electrically suppressed zero (P 72/96/144 PrS),
with zero adjustment, voltage drop approx. 900 mV
P 48 PrS P 72 PrS P 96 PrS
P 144 PrS
300 V
300 V
300 V
600 V
Scaling
pointer
response time
scale arrangement
scale characteristics
scale division
scale length
bar / knife - edge pointer
1 s for full - scale deflection
horizontal (left - hand zero)
linear
coarse - fine
P 48 PrS P 72 PrS P 96 PrS P 144 PrS
30 mm
45 mm
67 mm
92 mm
Accuracy at Reference Conditions
accuracy class
1.5 ' according to DIN EN 60 051 - 1
reference conditions
ambient temperature
position of use
input
others
23°C
nominal position ±1°
rated measuring value
DIN EN 60 051 - 1
influences
ambient temperature
position of use
stray magnetic field
23°C±2K
nominal position ±5°
0.5 mT
operating
temperature range
storage
temperature range
relative humidity
shock resistance
vibration resistance
climatic class 2 '
according to VDE/VDI 3540 sheet 2
–25 ... +40°C '
–25 ... +65°C
75% annual average, non–condensing
15 g, 11 ms
2.5 g, 5 ... 55 Hz
Rules and Standards
DIN 43 718
Measurement and control; front - frames and
frontpanels of measurement and control
equipment; principal dimensions
DIN 43 802
Line scales and pointers for indicating
electrical measuring instruments;
general requirements
DIN 16 257
Nominal positions and position symbols used
for measuring instruments
DIN EN 60 051
Direct acting indicating analogue electrical
measuring instruments and their accessories
–1
Part 1: Definitions and general requirements
common to all parts
–2
Part 2: Special requirements for ammeters
and voltmeters
–9
Part 9: Recommended test methods
DIN EN 60 529
Enclosure codes by housings (IP - code)
DIN EN 61 010 - 1
Safety requirements for electrical measuring,
control and laboratory equipment
Part 1: General requirements
DIN EN 61 326 - 1
Electrical equipment for measurement, con trol and laboratory use – EMC requirements
Part 1: General requirements
DIN IEC 61 554
Panel mounted equipment –
Electrical measuring instruments –
Dimensions for panel mounting
VDE/VDI 3540 sheet 2 reliability of measuring and control
equipment (classification of climates)
(non - condensing)
Options
additional measuring
ranges
accuracy class
adjustment of
internal resistance
increased sensitivity
adjustment potentiometer installed in
voltmeters, adjustment range approx.
±10% or ±20 ... 50% (except P 48/72 PrS),
ammeters on request
with 3rd terminal for voltmeters,
2nd figuring and 1 or 2 scale divisions
(except P 48/72 PrS)
on request
Connections
DC voltage
*
DC current
17
18
17
L+
L+
L–
L–
1.0 with fine scale division (as far as possible)
to ±1% at 23°C
* P 72/96 PrS voltmeters ≥300 V
P 48 PrS
lead resistance
to 2 kW/V, 5 kW/V, 10 kW/V or 20 kW/V
for voltmeters 1 V (as far as possible)
calibration of a total value >0.05W
case
window
colour of bezel
position of use
non–glaring glass
gray (similar to RAL 7037)
horizontal or on request 15...165°
dial
scale arrangement
blank dial
scale division
and figuring
2nd scale division
additional lettering
additional figuring
coloured marks
coloured sector
logo on the dial
zero position
expanded scale
for P 72/96/144 PrS
d
b
limited use in the tropics, climatic class 3
according to VDE/VDI 3540 sheet 2
–10 ... +55°C
non–certified
IP 54 splash - water protected front
(without zero adjustment)
terminal protection against accidental contact
protective sleeves B6 for P 48 PrS
SW6, SW10 (ammeters >3A) for P 72/96 PrS
vertical (bottom zero)
pencil - marked on initial and end values
0 ... 100%,
linear, full–scale values acc. to standardized
series (1 - 1.2 - 1.5 - 2 - 2.5 - 3 - 4 - 5 - 6 - 7.5
and their decimal multiples e.g. 150 m3/h) or
deviating from standard;
special calibration from customer’s
non–linear graph or chart;
scaling of voltmeters in ohms;
captions on request
linear including figuring,
non - linear including figuring
on request e.g. ”generator”
on request
red, green or blue for important scale values
red, green or blue within scale division
none or on request
centre zero or off–set zero,
mechanically suppressed zero, no zero
adjustment, max. 40% of full–scale value
for ammeters 100 mA, voltmeters 60 mV
electrically suppressed zero
for voltmeters 6 V (P 72/96/144 PrS only)
expanded initial scale division by means of
electronic circuits up to approx. 5% of
full - scale value in centre of scale
c
a
P 72/96 PrS
c
a
P 144 PrS
b
with operating
temperature range
marine application
enclosure code
Dimensions
b
performance
climatic suitability
18
d
2nd measuring range
deviating from standard
dial translucent
internal LED 24 V DC
1 lamp 6 V, 12 V or 24 V
2 lamps 6 V, 12 V or 24 V
2 pluggable LEDs 24 V DC / 0.4 W
d
measuring range
special measuring
range
measuring range
adjustment
dial illumination
for P 48 PrS
for P 96 PrS
for P 144 PrS
for P 144 PrS
c
a
dimensions (in mm) P 48 PrS P 72 PrS P 96 PrS P 144 PrS
a
48
72
96
144
b
24
36
48
72
c
75
94
107
192
d
17
32
43
67
scales and position of use
II
I
a
a
III
IV
VI
V
vertical mounting
I
horizontal scale (standard)
II vertical scale
inclined mounting
III horizontal scale
IV vertical scale
horizontal mounting
V horizontal scale
VI vertical scale
Ordering Information
type
P
front dimensions
48 PrS
72 PrS
96 PrS
144 PrS
measuring ranges
”live zero”
special measuring
range
measuring range
adjustment
dial
edgewise - type moving - coil panel meter
48 mm x 24 mm
72 mm x 36 mm
96 mm x 48 mm
144 mm x 72 mm
refer to preceding table
4 ... 20 mA mechan. suppressed zero 1)
0/4 ... 20 mA electrically suppressed zero 3)
on request 2)
none 1)
voltage ±10%
voltage ±20 ... 50%
2nd measuring range none 1)
1 scale division, 2nd figuring
2 scale divisions, 2 figurings
accuracy class
1.5 1)
1.0 with fine scale division as far as possible
adjustment
internal resistance to ±20% 1)
internal resistance to ±1% at 23°C
lead resistance >0.05 W
sensitivity,
1 kW/V 1)
voltmeters
to approx. 2 kW/V
to approx. 5 kW/V
to approx. 10 kW/V
to approx. 20 kW/V as far as possible
window
glass 1)
non–glaring glass
colour of bezel
black (similar to RAL 9005) 1)
gray (similar to RAL 7037)
position of use
vertical 1)
horizontal
on request 15 ... 165° 2)
climatic suitability
class 2, –25 ... +40°C 1)
class 3, –10 ... +55°C
marine application
none 1)
non–certified
enclosure code
IP 52 1)
IP 54 splash - water protected front
terminal protection
none 1)
protective sleeves B6, SW6 resp. SW10
scale arrangement
horizontal 1)
vertical
Weigel Meßgeräte GmbH
Postfach 720 154 S 90241 Nürnberg S Phone: 0911 / 4 23 47- 0
Erlenstraße 14 S 90441 Nürnberg S Fax: 0911 / 4 23 47- 39
Sales:
Phone: 0911 / 4 23 47- 94
Internet:
http://www.weigel–messgeraete.de
e–mail:
vertrieb@weigel–messgeraete.de
dial illumination
for P 48 PrS
for P 96 PrS
for P 144 PrS
for P 144 PrS
logo
zero position
1)
2)
3)
scale division & measuring range alike 1)
blank dial
scale division and figuring
0 ... 100%
linear acc. to standardized series 2)
linear deviating from standard 2)
calibration fr. non - linear graph or chart 2)
scaling in ohms for voltmeters 2)
2 scale divisions 2)
additional lettering on request 2)
additional figuring on request 2)
coloured marks red, green or blue 2)
coloured sector red, green or blue 2)
none 1)
internal LED 24 V DC
1 lamp 6 V, 12 V or 24 V
2 lamps 6 V, 12 V or 24 V
2 pluggable LEDs 24 V DC / 0.4 W
WEIGEL 1)
none
OEM logo 2)
left hand zero position 1)
centre or off - set zero position 2)
mechan. suppressed z.p.2) (≥100mA/60mV)
electrically suppressed z.p.2)3) (≥6V)
Standard
Please clearly add the desired specifications.
P 72/96/144 PrS only
ordering example
P 72 PrS, measuring range 0 ... 20 mA, horizontal scale 0 ... 100%,
vertical mounting, window non - glaring glass, WEIGEL logo
– specifications subject to change without notice; date of issue 02/13 –