QO Arc-Fault Circuit Breaker
QO-SWN
QO arc-fault circuit breakers provide protection for Series
and Parallel Type Arcing as required by the NEC and local
code adoption, and comply with UL1699.
Switch Neutral Common Trip 2008 NEC® 514.11
1P
QO-DF
One- Pole
1P 120 Vac
1P 120 Vac
10 k AIR
22 k AIR
Circuit Breaker Type Ampere
Rating
1 Space Required
1 Space Required
Cat. No.
$ Price
Cat. No.
$ Price
Combination Arc-fault
QO115CAFI 282.00 QO115VHCAFI 534.00
15
Interrupter
QO120CAFI 282.00 QO120VHCAFI 534.00
20
(Pigtail Neutral)
Plug-On Neutral
15
QO115PCAFI 282.00 QO115VHPCAFI 534.00
Combination Arc-fault
20
QO120PCAFI 282.00 QO120VHPCAFI 534.00
Interrupter
Two- Pole
2P 120/240 Vac
2P 120/240 Vac
10 k AIR
22 k AIR
Ampere
Circuit Breaker Type Rating
2 Space Required
2 Space Required
Cat. No.
$ Price
Cat. No.
$ Price
Combination Arc-fault
15
QO215CAFIf 636.00 QO215VHCAFIf 1068.00
Interrupter
20
QO220CAFIf 636.00 QO220VHCAFIf 1068.00
(Pigtail Neutral)
QO Combination Arc Fault and Ground Fault Circuit
Interrupters (Dual Function) provide overload and short
circuit protection, plus arc fault and ground fault protection in
accordance with the NEC, UL1699 and UL943.
Table 1.7:
Combination Arc-fault
and Ground Fault
Circuit Interrupter
(Pigtail Neutral)
Plug-On Neutral
Combination Arc-fault
and Ground Fault
Circuit Interrupter
1P 120 Vac
10 k AIR
1 Space Required
Cat. No.
$ Price
1P 120 Vac
22 k AIR
1 Space Required
Cat. No.
$ Price
15
QO115DF
326.00
QO115VHDF
578.00
20
QO120DF
326.00
QO120VHDF
578.00
15
QO115PDF
326.00
QO115VHPDF
578.00
20
QO120PDF
326.00
QO120VHPDF
578.00
HID circuit breakers are for use on circuits feeding fluorescent
and high intensity discharge (HID) lighting systems such as
mercury vapor, metal halide, or high pressure sodium. These
circuit breakers are physically interchangeable with QO circuit
breakers.
Table 1.11:
Ampere
Ratingc
15
20
25
30
40
50
2P
QO-GFI
Table 1.8:
QO-GFI Circuit Breakers
Ampere Ratingc
Qwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter
2P Common Trip 3P Common Trip
1P 120 Vac
120/240 Vac
208Y/120 Vac
10 k AIR
22 k AIR
10 k AIR
10 k AIR
3 Spaces
1 Space Required 1 Space Required 2 Spaces Required
Required
$
$
$
$
Cat. No. Price
Cat. No.
Price Cat. No. Price Cat. No. Price
15 QO115GFI 233. QO115VHGFI 482. QO215GFI 413. QO315GFI 791.
20 QO120GFI 233. QO120VHGFI 482. QO220GFI 413. QO320GFI 791.
25 QO125GFI 233. QO125VHGFI 482. QO225GFI 413.
—
—
30 QO130GFI 233. QO130VHGFI 482. QO230GFI 413. QO330GFI 791.
40
—
—
—
—
QO240GFI 413. QO340GFI 791.
50
—
—
—
—
QO250GFI 413. QO350GFI 791.
—
—
60
—
—
—
— QO260GFId 413.
QO-EPD/EPE
QO-EPD/EPE circuit breakers provide overload and short
circuit protection combined with Class B ground fault protection.
They are designed to provide ground fault protection of
equipment at a 30 mA level (EPD) or 100 mA level (EPE). They
are not designed to protect people from electrical shock.
Ampere Ratingc
Table 1.9:
QO
1P
With Shunt Trip
© 2012 Schneider Electric
All Rights Reserved
1P
120 Vac
10 k AIR
1 Space
Required
QO-EPD Circuit Breakers
2P Common Trip
120/240 Vac
10 k AIR
3P Common Trip
240 Vac
10 k AIR
2 Spaces Required
3 Spaces Required
$
$
$
Cat. No.
Cat. No.
Cat. No.
Price
Price
Price
15 QO115EPD 410. QO215EPD 660. QO315EPDe 1077.
20 QO120EPD 410. QO220EPD 660. QO320EPDe 1077.
—
—
25 QO125EPD 410. QO225EPD 660.
30 QO130EPD 410. QO230EPD 660. QO330EPDe 1077.
40
—
— QO240EPD 660. QO340EPDe 1077.
50
—
— QO250EPD 660. QO350EPDe 1077.
—
—
60
—
— QO260EPDd 660.
DE2A
10 k AIR
1 Space Required
Cat. No.
$ Price
38.10
QO115HIDb
b
38.10
QO120HID
QO125HID
38.10
QO130HID
38.10
QO140HID
38.10
QO150HID
38.10
2P Common Trip
120/240 Vac
10 k AIR
2 Spaces Required
Cat. No.
$ Price
QO215HID
87.00
QO220HID
87.00
QO225HID
87.00
QO230HID
87.00
QO240HID
87.00
QO250HID
87.00
3P Common Trip
240 Vac
10 k AIR
3 Spaces Required
Cat. No.
$ Price
QO315HID 300.00
QO320HID 300.00
QO325HID 300.00
QO330HID 300.00
—
—
—
—
QO-HM
High magnetic trip circuit breakers are recommended for
applications where high initial inrush may occur and for
individual dimmer applications.
Table 1.12:
QO-HM Circuit Breakers
120 Vac—10 k AIR
1P
Ampere
Ratingc
15 A
20 A
™
1P
QO-GFI
QO-HID Circuit Breakers
NOTE: QO-K Circuit Breakers are on page 1-27.
QO-GFI
Qwik-Gard circuit breakers provide overload and short circuit
protection, combined with Class A ground fault protection.
Class A denotes a ground fault circuit interrupter that will trip
when a fault current to ground is 6 mA or more, for people
protection. Do not connect to more than 250 feet of load
conductor for the total one-way run to prevent nuisance
tripping.
3 Wire 120/240 Vac
10 k AIR
3 Spaces Required
Cat. No.
$ Price
QO310SWN
143.00
QO315SWN
143.00
QO320SWN
143.00
QO325SWN
143.00
QO330SWN
143.00
QO340SWN
143.00
QO350SWN
143.00
QO-HID
QO-Dual Function Arc Fault Circuit
Breakersa
Ampere
Circuit Breaker Type Rating
Two-wire
QO-SWN
10
15
20
25
30
40
50
1P 120/240 Vac
QO-Dual Function Circuit Breaker
Three-wire
QO-SWN
2 Wire 120 Vac
10 k AIR
2 Spaces Required
Cat. No.
$ Price
QO210SWN
95.00
QO215SWN
95.00
QO220SWN
95.00
QO225SWN
95.00
QO230SWN
95.00
QO240SWN
95.00
QO250SWN
95.00
Ampere
Ratingc
Cat. No
QO115HMab
QO120HMab
$ Price
30.60
30.60
Non-automatic (Standard) Miniature Switches
Miniature non-automatic switches have the same physical
packaging as miniature circuit breakers, but open only when
the handle is switched to the OFF position.
Non-automatic switches provide no overcurrent protection or
short circuit protection. They must not be used on systems that
have an available fault current greater than the values listed in
the table.
Non-automatic switches are UL Listed per UL 1087 and are
CSA certified.
Table 1.13:
QO Non-Automatic Miniature Switches,
240 Vac 10 kA
Ampere
Rating
60
100
2P
Cat. No.
QO200
QO2000
3P
$ Price
70.00
200.00
Cat. No.
QO300
QO3000
$ Price
248.00
366.00
UL Listed as HACR type for use with air conditioning, heating and refrigeration
equipment having motor group combinations and marked for use with HACR
type circuit breakers.
b
UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac
fluorescent lighting loads.
c
10–30 A circuit breakers are suitable for use with 60oC or 75oC conductors.
35–60 A circuit breakers are suitable for use with 75oC conductors.
d
Suitable only for feeding 240 Vac and 208 Vac two-wire loads. Does not
contain load neutral connection.
e
See note in Instruction Bulletin when using in an enclosure with a QO403 or
QON prefix.
f
For 120/240 V only, not for 208Y/120 V.
Interrupting Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-2
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-12
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-54
a
$
Cat. No.
Price
QO315EPEe 1077.
QO320EPEe 1077.
—
—
QO330EPEe 1077.
QO340EPEe 1077.
QO350EPEe 1077.
—
—
Discount
Schedule
1-3
LOAD CENTERS
1P
QO-CAFI
QO Arc Fault Circuit Breakersa
QO-SWN Circuit Breakers
1
Table 1.6:
Table 1.10:
QO™ Load Centers
1Ø, Special Applications
Class 1130 / Refer to Catalog 1100CT0501
www.schneider-electric.us
1
1Ø2W—120Vac—1Ø3W—120/240 Vac—UL Listed
Table 1.26:
QO Special Application (Accepts Only QO Plug-On Circuit Breakers.)
Short
Circuit
Current
Rating
Mains
Rating
Max. 1P
Circuits a
Spaces
Load Center b
Box, Interior, and Cover
Equipment Ground Bar Kit
(Order Separately)
Max. Tandem
Circuit
Breakers
Cat. No.
0
2
QO2L30TTSd
QO24L50TTSe
51.00
78.00
Factory-installed
2
QO35FM30TTF/S
83.00
Factory-installed
2
6
6
8
8
QO24L70TSe
QO612L100TF/Sg
QO612L100DTF/Sg
QO816L100TF/Sg
QO816L100DTF/Sg
78.00
86.00
101.00
137.00
159.00
Factory
Installed
LOAD CENTERS
Manufactured Housing:
1Ø2W 120 Vac—Main Lugs Only—CSA Certified
30 Ac
10 kA
2
2
4
50 A
10 kA
2
$ Price
Cat. No.
Main Wire Size
AWG/kcmil
Al
Cu
Box No.
See
Page 1-17
12–10
—
14–10
14–6
1
2
$ Price
1Ø2W 120 Vac—Main Circuit Breaker—CSA Certified
30 A
10 kA
3
5
1Ø3W 120/240 Vac—Main Lugs Only—CSA Certified
70 A
10 kA
2
4
6
12
6
12
100 A
10 kA
8
16
8
16
3
f
12–3
14–4
2
4
4
4
4
4–1
Load Center with Cover: 1Ø3W 120/240 Vac—UL Listed Complete QO Load Center—Box, Interior and Combination Cover in One Package
Convertible Mains—Factory-Installed Main Lugs i—QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5)—Copper Bus
I
N
D
O
O
R
65 kA
65 kA
65 kA
12
12
20
0
12
0
6–2/0
6–2/0
6–2/0
6
6
7
6–250
6–250
9
9
13.40
17.10
15.80
17.10
18.80
4–1/0
4–1/0
4–1/0
4–1/0
6–2/0
5
5
6
6
8
Convertible Mains—Factory-Installed Main Circuit Breaker—
QOM2 Main Frame Size—Convertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)—Copper Bus j
QO12030M150C
843.00
PK18GTA
18.80
22 kA
20
30
10
150 A
QO130M150C
870.00
PK18GTA
18.80
22 kA
30
30
0
QO12040M200C
843.00
PK23GTA
21.30
22 kA
20
40
20
22 kA
30
30
0
QO130M200C
896.00
PK18GTA
18.80
200 A
QO13040M200C
974.00
PK23GTA
21.30
22 kA
30
40
10
22 kA
40
40
0
QO140M200C
1137.00
PK23GTA
21.30
4–250
4–250
4–250
4–250
4–250
4–250
9
9
9
9
9
10
125 A
12
24
20
QO112L125GC
QO11224L125GC
QO120L125GC
188.00
249.00
284.00
PK12GTA Incl.
PK15GTA Incl.
PK15GTA Incl.
Convertible Mains—Factory-Installed Main Lugs i—QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5)—Copper Bus
150 A
65 kA
30
30
0
QO130L150TC
452.00 PK23GTA, LK100AN Installed
200 A
65 kA
30
40
10
QO13040L200GC
575.00 PK23GTA, LK100AN Incl.
Convertible Mains—Factory-Installed Main Circuit Breaker—
QOM1 Main Frame Size—Convertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)—Copper Bus j
22 kA
22 kA
22 kA
22 kA
22 kA
100 A
125 A
12
12
16
20
32
12
20
16
20
32
0
8
0
0
0
QO112M100C
QO11220M100C
QO116M100C
QO120M100C
QO132M125C
351.00
413.00
395.00
446.00
1041.00
PK9GTA
PK15GTA
PK12GTA
PK15GTA
PK18GTA
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a
Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
b
Order F for flush device or S for surface device.
c
Mains rating 25 A when Al wire is used.
d
Will not accept Qwik-Gard™ QO-GFI or QO-AFI circuit breaker.
e
Use 10 AWG maximum size wire for GFI and AFI circuit breakers.
f
Main circuit breaker is a field-installed standard QO single pole circuit breaker. Order separately from page 1-2.
g
70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker.
h
UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
i
UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
j
22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22,000 A available fault current.
Table 1.27:
Service Upgrade Load Centers: 1Ø3W 120/240Vac—UL Listed Load Center with Removable End Walls
Convertible Mains—Factory-Installed Main Breaker—22KA
QOM2 Main Frame Size—Convertible to Main Lugs (See page1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)j
I
N
D
O
O
R
k
l
m
Mains
Rating
Spaces
Max. 1P
Circuitsa
Max.
Tandem
Circuit
Breakers
$ Price
(Interior,
Box and
Cover)
Load Center
Box and Interior
Extra Long Cover with Door
(Order Separately)
Cat. No.
Flush
Cat. No.
$ Price
Surface
Cat. No.
30
60
30
959.00 HOM3060M200PCEPk 959.00 HOMC30UFL
200 A
40
40
0
1137.00
QO140M200EPm
1137.00 QOC40UFL
Ships with standard length cover
Blank Endwall Plates (4) Available Order: EWPLATE $36.00
Copper Bus, order cover separately QOC40UF/S or QOC40UFL
Table 1.28:
—
—
Main Wire Size Equipment Ground Bar
AWG / kcmil
Kit (Order Separately)
$ Price
111.00
111.00
Al
Cu
4-250
Cat. No
PK23GTA
PK23GTA
Box No.
See Page
1–17
$ Price
21.30
21.30
10
10
Auxiliary Gutter
UL Listed for use with standard 1Ø and 3Ø load centers for riser applicationsn. For auxiliary gutter-load center compatibility, see catalog number 1100CT0501
Cat. No.
n
o
$ Price
SDAG26
338.00
One tap kit required for each riser wire.
When used with B300 bolt-on hubs.
Table 1.29:
Cover
Conduit Riser Size
Width
Height
Depth
Flush
1-3/4, 2, 2-1/2 or o3
13.50
26.12
3.75
Tap Kits 120/240 Vac—UL Listed for use with Auxiliary Gutter SDAG26
Cat. N0.
$ Price
Use with Auxiliary
Gutter Cat. No.
SDGT30020
SDGT300300
81.00
120.00
SDAG26
SDAG26
SDGT300C10C
49.70
SDAG26
SDGT300C300C
70.00
SDAG26
QOGL20 Grounding Terminals
40.70
SDAG26
1-10
Riser Wire
Lug Type
Mechanical (Included)
Mechanical (Included)
Anderson VCEL030516H1
(Not included)
Anderson VCEL030516H1
(Not included)
Mechanical (Included)
DE3A
Discount
Schedule
Tap Off Wire
Al/Cu Wire Size
(2) 6 AWG–300 kcmil
(2) 6 AWG–300 kcmil
(2) 4 AWG–300 kcmil
(2) 4 AWG–300 kcmil
(2) 6–2/0 AWG
Lug Type
Mechanical (Included)
Mechanical (Included)
Anderson VCEL02114S1
(Not Included)
Anderson VCEL030516H1
(Not included)
—
Al/Cu Wire Size
(1) 6–2/0 AWG
(1) 6 AWG–300 kcmil
(1) 8–1/0 AWG
(1) 4 AWG–300 kcmil
—
© 2012 Schneider Electric
All Rights Reserved
QO™ and Homeline™ Load Centers and Circuit Breakers
1Ø, Value Packs and Riser Panels
Class 1130, 1170 / Refer to Catalog 1100CT0501
www.schneider-electric.us
1Ø3W—120/240 Vac—UL Listed
I
N
D
O
O
R
R
A
I
N
P
R
O
O
F
Value Packs Contains Complete Load Center (Box, Interior and Cover) with Selected Branch Circuit Breaker
Load Center
Box, Interior, Cover and Branch Circuit Breakers
Cat. No.
Included Load Center/Circuit Breakers
$ Price
Equipment
Ground Bar Kit
(Order Separately)
Cat. No. $ Price
Main
Wire Size
AWG/kcmil
Al/Cu
QO (Accepts Only QO Plug-On Circuit Breakers) QO—Copper Bus
Convertible Mains—Factory-Installed Main Circuit Breaker,
10 kA Short Circuit Current Rating Convertible appropriate QOM 22 kA Short Circuit Current Rating Main Circuit Breaker (See page 1-16)
125 A 24
24
0
QO124L125PGCVP (1) QO124L125PGC, (3) QO120, (2) QO230
793.00 PK15GTA Included
6–2/0
225 A 42
42
0
QO142L225PGCVP (1) QO142L225PGC, (3) QO120, (2) QO230
1239.00 (2) PK15GTA Included
6–300
Convertible Mains—Factory-Installed Main Circuit Breaker,
22 kA Short Circuit Current Rating Convertible appropriate to Main Lugs (See page 1-6) or QOM Main Circit Breaker (See page 1-5)
24
0
QO124M100PCVP
(1) QO124M100PC, (3) QO120, (2) QO230
1050.00 PK15GTA
17.10
6–2/0
100 A 24
32
32
0
QO32M100VP
(1) QO132M100C, (3) QO120, (2) QO230
949.00 PK18GTA
18.80
4–2/0
30
40
10
QO3040M200VP
(1) QO13040M200C, (3) QO120, (2) QO230
1195.00 PK23GTA
21.30
QO142M200PCVP
(1) QO142M200PC, (3) QO120, (2) QO230
1581.00 PK23GTA
21.30
200 A 42
42
0
4–250
42
42
0
QO142M200PCAFVP (1) QO142M200PC, (3) QO120, (2) QO230, (3) QO115PCAFI
2427.00 PK23GTA
21.30
Homeline (Accepts Only HOM Plug-On Circuit Breakers)
Convertible Mains—Factory-Installed Main Lugs,
10 kA Short Circuit Current Rating Convertible to appropriate QOM 22 kA Short Circuit Current Rating Main Circuit Breaker (See page 1-16)
HOM1224L125PGCVP (1) HOM1224L125PGC, (2) HOM120
309.00 PK15GTAL Included 6–2/0
6–1
125 12
24
12
PK15GTAL &
HOM3060L225PGCVP (1) HOM3060L225PGC, (3) HOM120, (2) HOM230
677.90
4–300 4–250
225 A 30
60
30
PK15GTA Incl.
Convertible Mains—Factory-Installed Main Circuit Breaker,
22 kA Short Circuit Current Rating Convertible appropriate to Main Lugs or Main Circuit Breaker (See page 1-16)
HOM2040M100PCVP (1) HOM2040M100PC, (2) HOM120, (1) HOM230
528.00 PK18GTA
18.80 6–1
6–3
20
40
20
HOM2040M100PC1AVP (1) HOM2040M100PC, (2) HOM120, (1) HOM230, (1) HOM115PCAFI
855.00 PK18GTA
18.80 6–1
6–3
40
20
100 A 20
24
48
24
HOM2448M100PCVP (1) HOM2448M100PC, (3) HOM120, (2) HOM230
713.00 PK23GTA
21.30 6–2/0 6–1/0
150 A 30
60
30
HOM3060M150PCVP (1) HOM3060M150PC, (3) HOM120, (2) HOM230
1078.00 PK23GTA
21.30
4–250
20
40
20
HOM2040M200PCVP (1) HOM2040M200PC. (3) HOM120, (2) HOM230
926.00 PK18GTA
18.80
30
60
30
HOM3060M200PCVP (1) HOM3060M200PC. (3) HOM120, (2) HOM230
1091.00 PK23GTA
21.30
30
60
30
HOM3060M200PC1AVP (1) HOM3060M200PC. (3) HOM120, (2) HOM230, (1) HOM115PCAFI 1358.00 PK23GTA
21.30
HOM3060M200PCAFVP (1) HOM3060M200PC. (3) HOM120, (2) HOM230, (3) HOM115PCAFI 1814.00 PK23GTA
21.30
200 A 30
4–250
60
30
40
80
40
HOM4080M200PCVP (1) HOM4080M200PC, (3) HOM120, (2) HOM230
1218.00 PK27GTA
33.80
40
80
40
HOM4080M200PC1AVP (1) HOM4080M200PC, (3) HOM120, (2) HOM230, (1) HOM115PCAFI 1485.00 PK27GTA
33.80
40
80
40
HOM4080M200PCAFVP (1) HOM4080M200PC, (3) HOM120, (2) HOM230, (3) HOM115PCAFI 2288.00 PK27GTA
33.80
Homeline (Accepts Only HOM Plug-On Circuit Breakers)
Convertible Mains—Factory-Installed Main Circuit Breaker,
22 kA Short Circuit Current Rating Convertible to Main Lugs or Lower Amperage QOM2 Main Circuit Breaker (See page 1-16)
125 A 12
24
12
HOM1224M125PRBVP (1) HOM1224M125PRB, (3) HOM120, (2) HOM230
850.00
PK23GTA
21.30
200 A 30
60
30
HOM3060M200PRBVP (1) HOM3060M200PRB, (3) HOM120, (2) HOM230
1351.00
PK23GTA
21.30
6–2/0
6–1
4–250
Box No.
See
Pages
1-17, 1-18
7
12
7
8
9
11
11
6
10
7
7
8
10
9
10
10
10
12
12
12
3R
7R
QO Riser Panels
Table 1.31:
Mains
Rating
I
N
D
O
O
R
Offset Interior for Wide Gutter—30 A Maximum Branch Circuit Breaker on left side of interiorab
(Accepts Only QO Plug-On Circuit Breakers)
Spaces
Max.
Single
Pole
Circuitsc
Max.
Tandem
Circuit
Breakers
Load Center Box and Interior
Cat. No.
$ Price
Load Center Cover
Cat. No.
$ Price
Equipment
Ground Bar Kit
(Order Separately)
Cat. No.
Main
Wire Size
AWG/kcmil
$ Price
Al
Cu
Box No.
See
Page 1-17
Convertible Mains—Factory-Installed Main Lugs,
65 kA Short Circuit Current Rating Convertible to QOM1 22 kA Short Circuit Current Rating Main Circuit Breaker (See page 1-5) when used with QOC cover below—Copper Bus
QO11224L125WG
338.00 QOC20UFWG
53.00
PK15GTA
17.10
14
12
24
12
6–2/0
125 A
20
30
10
QO12030L125WG
465.00 QOC20UFWG
53.00
PK15GTA
17.10
14
Convertible Mains-Factory—Installed Main Lugs,
65 kA Short Circuit Current Rating Convertible to QOM2 22 kA Short Circuit Current Rating Main Circuit Breaker (See page 1-5) when used with QOC cover below—Copper Bus
200 A
30
40
10
QO13040L200WG
701.00
QOC30UFWG
102.00
PK23GTA
Convertible Mains—Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating Convertible to Main Lugs (See page 1-6)
or Lower Amperage QOM2 Main Circuit Breaker (See page 1-5) when used with QOC cover below—Copper Bus
QO124M200WG125d
683.00 QOC30UFWG
102.00
PK23GTA
200 A
24
24
0
21.30
4–250
23
21.30
4–250
23
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a
UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
b
UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
c
Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
d
Comes with 125 A main circuit breaker factory installed.
Panelboard-style Covers for Riser Panels
Mono-Flat™ Front available for riser panels as an alternative to standard load center cover listed above. Provides a low-profile, aesthetically pleasing
solution for high-traffic areas in upscale multi-family applications. Deadfront included. Lock kit not provided. Cover NQC30FWG CANNOT be used
when panel has been converted to a main circuit breaker panel. e
Mains Rating of Load Center
e
Cat. No.
125 A
NQC20FWG
NQC30FWG
200 A
Order catalog number PK4FL for field-installed lock kit.
© 2012 Schneider Electric
All Rights Reserved
$ Price
117.00
180.00
DE3A
Discount
Schedule
1-11
LOAD CENTERS
Max.
Max.
Tandem
1P
Circuit
Circuitsc
Breakers
1
Mains
Rating
Spaces
Table 1.30:
Load Center Accessories
QO and Homeline Load Center Accessories
Class 1130, 6610 / Refer to Catalog 1100CT0501
www.schneider-electric.us
QO Load Center Accessories
Filler Plates
Door Lock Kits
Neutral / Ground Lugs
Ground Bar Kits
Handle Padlock Attachment
a
Cat. No.
50–125 A
100–225 A
For padlocking main circuit breakers in convertible load centers OFF
$ Price Schedule
QOFP
QOM1FP
QOM2FP
KFP
Q2FP
3.60
20.30
20.30
20.30
20.30
DE3A
DE3A
DE3A
DE3A
DE3A
PK8FLa
98.00
DE3A
PK6FL
93.00
DE3A
PK4FL
LK70AN
LK100AN
LK125AN
LK150AN
90.00
10.10
10.80
22.10
32.40
PE1A
DE3A
DE3A
DE3A
DE3A
LK225AN
33.20
DE3A
PK15GTAL
PK18GTAL
PK23GTAL
PKGTAB
QOM1PA
QOM2PA
35.00
37.80
40.70
43.80
11.00
11.00
DE3A
DE3A
DE3A
DE3A
DE2E
DE2E
QO403L60NF/S does not have provisions for a field-installed lock.
QOFP
PKGTAB
PK4FL
PK6FL and PK8FL
Table 1.35:
Homeline Load Center Accessories
Description
Handle Padlock Attachment
Cat. No.
50–125 A
100–225 A
For padlocking main circuit breakers in convertible load center, “OFF”
Fills opening in covers if twistout is removed in error
Filler Plates
Neutral Lugs
Retaining Kit for Breakers
Used as Back-fed Mains
100–125 A
150–225 A
Fills main circuit breaker opening in convertible load centers
Field-installed for 14–2 AWG Al or 14–4 AWG Cu wire
Field-installed for 6–2/0 AWG Al/Cu wire
Field-installed for 14–2/0 AWG Al/Cu wire
Field-installed for 4 AWG to 300 kcmil Al/Cu wire. Use in Series S,
150–225 A QO load center and S03 and below, 150–225 A HOM load center.
Field-installed for 4 AWG–300 kcmil Al/Cu wire. Use in Series S04, 150–225 A HOM load center
Secures circuit breaker to interior when used as a back-fed main.
For HOM612L100F/S, RB and HOM48L125GC, GRB load centers
Secures ONE circuit breaker right side of interior when used as a back-fed main
For 100–125 A convertible main load centers, Series S01 and S02
Secures ONE circuit breaker right side of interior when used as a back-fed main
For 150–225 A convertible main load centers, Series S01 and S02
Secures circuit breaker to interior when used as a back-fed main
For 2P 150–200 A circuit breakers
$ Price Schedule
QOM1PA
QOM2PA
HOMFP
QOM1FP
QOM2FP
LK70AN
LK100AN
LK125AN
11.00
11.00
3.20
20.30
20.30
10.10
10.80
22.10
DE2E
DE2E
DE3C
DE3A
DE3A
DE3B
DE3B
DE3B
DE3A
LK225AN
33.20
LK225ANHOM
33.20
DE3A
HOM1RK
6.50
DE3C
HOM4RK2LA
14.70
DE3C
HOM4RK2HA
14.70
DE3C
HOM5RK
14.70
DE3C
Door Lock Kit
Use with convertible indoor load center covers (Series S-1)
PK6FL
93.00
DE3A
Replacement Cover Directory Label
1 through 42 numbered universal replacement directory label for load center covers
LSDL
0.54
DE5
Circuit Identification Stickers
Circuit identification stickers for use on cover directory labels to identify branch circuits
PSDS
0.75
Generator Circuit
Breaker Interlock Kit
For use on “S” Series NEMA 1 and NEMA 3R load centers. Interlocks a QOM1 2P main
circuit breaker of a load center (100–125 A) with a Homeline 2P (15–125 A) branch circuit breaker
For use on “S” Series NEMA 1 and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker
of a load center (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker
For use on “S2” and “S3” Series NEMA 3R QOM2 load centers. Interlocks a QOM2 2P main circuit breaker of a
load center (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker
© 2012 Schneider Electric
All Rights Reserved
DE2E
DE3A
DE3B
DE3C
DE3D
DE3E
DE5
PE1A
Discount
Schedule
DE5
HOMCRBGK1
105.00
DE3D
HOMCGK2
105.00
DE3D
HOMRBGK2
105.00
DE3D
1-13
LOAD CENTERS
Description
Fills opening in covers if twistout is removed in error
Fills main circuit breaker opening in convertible load center covers100–125 A
Fills main circuit breaker opening in convertible load center covers150–225 A
Fills main circuit breaker opening in 3Ø load center covers (S01 and S02 Series)
Fills main circuit breaker opening in “Q” style 3Ø load center covers (S03 Series)
Use with QO612L100DF/S, QO612L100DFCU/SCU, QO612L100DTF/S, QO816L100DF/S,
QO816L100DFCU/SCU, QO816L100DTF/S, QO48M30DSGP, or QO48M60DSGP
Use with convertible mains, 1Ø and 3Ø 100–225 A, and fixed mains,
3Ø 125–225 A indoor load centers
Use with 300 and 400 ampere indoor load centers
Field-installed for 12– 2 Al or 14–4 Cu AWG wire
Field-installed for 6–2/0 Al/Cu AWG wire
Field-installed for 14–2/0 Al/Cu AWG wire
Field-installed for 2–3/0 Al/Cu AWG wire
Field-installed for 4 AWG to 300 kcmil Al/Cu wire. Use in Series S,
150–225 A QO load center and S03 and below, 150–225 A HOM load center.
Standard PK15GTA with a 1–4/0 Al/Cu Lug
Standard PK18GTA with a 1–4/0 Al/Cu Lug
Standard PK23GTA with a 1–4/0 Al/Cu Lug
Insulator Kit for PK7GTA through PK27GTA
1
Table 1.34:
Homeline™ Circuit Breakers
Plug-On Circuit Breakers
Class 1170 / Refer to Catalog 1100CT0501
www.schneider-electric.us
1
The Square D Homeline circuit breakers are in a 1 in. wide
format for 1-pole circuit breakers. They are designed to
plug into Homeline load centers.
Table 1.42:
HOMT Tandem Circuit Breakers
Ampere Ratinge
Table 1.36:
LOAD CENTERS
HOM 1P
1 Space Required
HOM 2P
2 Spaces Required
HOMT 1P
1 Space Required
HOM
Ampere
Rating
AIR
15 A
20 A
25 A
30 A
35 A
40 A
45 A
50 A
60 A
70 A
80 A
90 A
100 A
110 A
125 A
150 A
175 A
200 A
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
1P—120/240 Vac
Cat. No.
$ Price
HOM115 ab
HOM120 ab
HOM125 b
HOM130 b
—
HOM140 b
—
HOM150 b
—
—
—
—
—
—
—
—
—
—
Table 1.37:
2P—120/240 Vac Common Trip
26.30
26.30
26.30
26.30
—
26.30
—
26.30
—
—
—
—
—
—
—
—
—
—
Cat. No.
$ Price
HOM215 b
HOM220 b
HOM225 b
HOM230 b
HOM235 b
HOM240 b
HOM245 b
HOM250 b
HOM260 b
HOM270 b
HOM280 b
HOM290 b
HOM2100 b
HOM2110 b
HOM2125 b
HOM2150BB bd
HOM2175BB bd
HOM2200BB bd
60.00
60.00
60.00
60.00
60.00
60.00
60.00
60.00
60.00
123.00
168.00
168.00
168.00
369.00
369.00
428.00
428.00
428.00
HOM-HM
High magnetic trip circuit breakers are recommended for applications
where high initial inrush current may occur.
1P—120/240 Vac
Amperes
Cat. No.
HOM115HMb
HOM120HMb
15 A
20 A
HOM2200BB
Branch Circuit Breaker
4 Spaces Required
Table 1.38:
2Ps
$ Price
27.60
27.60
—
—
—
HOM-CAFI
Homeline Combination Arc Fault Circuit Interrupters—Provide overload
and short circuit protection, plus arc fault protection in accordance with
the NEC and UL1699.
Ampere
Rating
Circuit Breaker Type
Poles
120 Vac
Cat. No.
$ Price
HOMT Quad
Circuit Breaker
2 Spaces Required
HOM115CAFIbc
267.00
1
HOM120CAFIbc
267.00
1
HOM115PCAFIbc
267.00
1
HOM120PCAFIbc
267.00
15 A
2
HOM215CAFIbc
595.00
20 A
2
HOM220CAFIbc
595.00
15 A
1
20 A
15 A
20 A
Table 1.43:
HOMT Quad Tandem Circuit Breakers
Ampere Rating e
1P
Table 1.39:
HOM 1P CAFI
HOM-DF
Homeline Combination Arc Fault and Ground Fault Circuit Interrupters
(Dual Function)—Provide overload and short circuit protection, plus arc
fault and ground fault protection in a single device in accordance with
the NEC, UL1699 and UL943.
Ampere Poles
Rating 120 Vac
Circuit Breaker Type
Combination Arc-Fault and
Ground Fault Circuit Interrupter
with Pigtail Neutral
Plug-On Neutral Combination
Arc-Fault and Ground Fault
Circuit Interrupter
HOM 1P DF
Table 1.40:
Cat. No.
$ Price
15 A
1
HOM115DFb
312.00
20 A
1
HOM120DFb
312.00
15 A
1
HOM115PDFb 312.00
20 A
1
HOM120PDFb 312.00
HOM-GFI
HOM-GFI circuit breakers provide overload and short circuit protection,
combined with Class A ground fault protection. Class A denotes a
ground fault circuit interrupter that will trip when a fault current to
ground is 6 milliamperes or more.
2P—120/240 Vac
Common Trip
1P—120 Vac
Ampere
Rating
HOM 1P GFI
(With Ground Fault
Circuit Interrupter)
1 Space Required
15 A
20 A
30 A
40 A
50 A
AIR
10 kA
10 kA
10 kA
10 kA
10 kA
Table 1.41:
1 Space Required
Cat. No.
HOM115GFI
HOM120GFI
—
—
—
2 Spaces Required
$ Price
212.00
212.00
—
—
—
Cat. No.
HOM215GFI
HOM220GFI
HOM230GFI
HOM240GFI
HOM250GFI
$ Price
413.00
413.00
413.00
413.00
413.00
HOM-EPD—10 k AIR
Homeline Equipment Protection Device—Circuit Breakers with 30 mA
Equipment Ground Fault Protection (UL Listed)
2P—120/240 Vac
1P—120 Vac
Common Trip
Amperes
Cat. No.
HOM 2P GFI
(With Ground Fault
Circuit Interrupter)
2 Spaces Required
1-14
15 A
20 A
25 A
30 A
40 A
50 A
HOM115EPD
HOM120EPD
—
—
—
—
$ Price
374.00
374.00
—
—
—
—
DE3D
Cat. No.
$ Price
HOM215EPD
HOM220EPD
HOM225EPD
HOM230EPD
HOM240EPD
HOM250EPD
DE3C
DE2E
660.00
660.00
660.00
660.00
660.00
660.00
Discount
Schedule
AIR
2P Tandem—120/240 Vac (Two Spaces
Required)
2P
Cat. No.
$ Price
(2) 15 A
15 A
10 kA
HOMT1515215 b
120.00
HOMT1515220 b
120.00
(2) 15 A
20 A
10 kA
HOMT1515225 b
120.00
(2) 15 A
25 A
10 kA
HOMT1515230 b
120.00
(2) 15 A
30 A
10 kA
HOMT1515240 b
120.00
(2) 15 A
40 A
10 kA
HOMT1515250 b
120.00
(2) 15 A
50 A
10 kA
HOMT2020220 b
120.00
(2) 20 A
20 A
10 kA
(2) 20 A
25 A
10 kA
HOMT2020225 b
120.00
HOMT2020230 b
120.00
(2) 20 A
30 A
10 kA
HOMT2020240 b
120.00
(2) 20 A
40 A
10 kA
HOMT2020250 b
120.00
(2) 20 A
50 A
10 kA
Note: Typical catalog number (e.g. HOMT 1515230) represents two 1P, outer
poles (two 15 A 1P CBs) and one 2P inner circuit breaker with common
trip (one 30 A 2P CB).
Table 1.44:
Circuit Breaker Wire Sizesf
Wire Size (AWG/kcmil)
Breaker Type
Ampere
Rating
Aluminum
HOM
1P
15–30 A
14–8 AWG
HOM
2P
Two-Pole
Combination Arc-Fault
Circuit Interrupter with
Pigtail Neutral
1P Tandem—120/240 Vac (One Space
Required)
Cat. No.
$ Price
15 and 15 A
10 kA
HOMT1515 b
52.00
15 and 20 A
10 kA
HOMT1520 b
52.00
HOMT2020 b
52.00
20 and 20 A
10 kA
HOMT3015 b
52.00
30 and 15 A
10 kA
HOMT3020 b
52.00
30 and 20 A
10 kA
a
UL Listed as SWD (switching duty) rated. Suitable for switching 120
Vac fluorescent lighting loads.
b
UL Listed as HACR type for use with air conditioning, heating and
refrigeration equipment having motor group combinations and marked
for use with HACR type circuit breakers.
c
For 120/240 V only, not for 208Y/120 V.
One-Pole
Combination Arc-Fault
Circuit Interrupter with
Pigtail Neutral
Plug-On Neutral
Combination Arc-Fault
Interrupter
AIR
HOMT and Quad
Quad Only
HOM-GFI - 1P
HOM-GFI - 2P
Table 1.45:
40–50 A
8–2 AWG
15–30 A
14–8 AWG
35–70 A
80–125 A
150–200 A
15–30 A
40–50 A
15–20 A
15–50 A
8–2 AWG
4–2/0 AWG
4 AWG–300 kcmil
14–8 AWG
6–12 AWG
14–10 AWG
12–4 AWG
Copper
14–8 AWG or
(2) 14–10 AWG
8–2 AWG
14–8 AWG or
(2) 14–10 AWG
8–2 AWG
4–2/0 AWG
4 AWG–300 kcmil
14–8 AWG
6–14 AWG
14–10 AWG
14–6 AWG
Accessories
Description
Cat. No.
$ Price
Handle Attachments
Handle Tie: Converts any two adjacent 120/240 Vac
HOM1HTh
3.50
single HOM circuit breakers to independent trip 2P
Handle Tie: Converts any two adjacent 120/240 Vac
HOMTHTh
3.80
1P side-by-side HOMT circuit breakers to
independent trip 2P
Handle Clamp: Clamp for holding HOM 1P handle in
QO1LOi
3.80
the ON or OFF position
Handle Blocking Device: Attaches to standard HOM
10.70
2P circuit breakers for holding the handle in the OFF HOM2HBDh
position
Handle Padlock Attachment: For padlocking 1P
HOM1PAh
9.90
Standard HOM breakers in the ON or OFF position
HOM2PALAh
9.90
15–70
A
Handle Padlock Attachment: For
80–125 A HOM2PAHAh
padlocking 2P Standard HOM circuit
9.90
breakers in ON or OFF position
150–200 A HOM2PAVHAh 50.00
Handle Padlock Attachment: For padlocking 1P CAFI,
DF, GFI, and EPD HOM breakers in ON or OFF
HOMELEC1PA
9.90
position
Handle Padlock Attachment: For padlocking 2P CAFI, HOMELEC2PALA 9.90
GFI, and EPD HOM breakers in ON or OFF position
Handle Padlock Attachment: For padlocking center
HOMQPA
9.90
poles of Homeline Quad breakers in the OFF position
Handle Padlock Attachment: For
11.00
50–125 A QOM1PAgi
padlocking main circuit breakers in
11.00
convertible load center in OFF position 100–225 A QOM2PAgi
Sub-Feed Lugs
HOML2125
47.60
125 A 2P plug-on—2 spaces required
225 A 2P plug-on—4 spaces required
HOML2225d 296.00
d
Requires four spaces (1 AWG–300 kcmil Al/Cu). Use only in 1Ø panel
rated 150 A or greater.
e
15–20 A tandem or quad tandem circuit breakers are suitable for use
with 60oC or 75oC conductors. 25–50 A tandem or quad tandem circuit
breakers are suitable for use with 75oC conductors only.
f
15–30 A circuit breakers are suitable for use with 60oC or 75oC
conductors. 40–125 A circuit breakers are suitable for use with 75oC
conductors.
g
50–125 A QOM1 frame size; 100–225 A QOM2 frame size.
h
DE3C Discount Schedule
i
DE2E Discount Schedule
© 2012 Schneider Electric
All Rights Reserved
Homeline™ Load Centers
Indoor, 1Ø, Main Lugs and Main Circuit Breaker
Class 1170 / Refer to Catalog 1100CT0501
www.schneider-electric.us
1Ø3W—120/240 Vac—UL Listed
Spaces
Max.
Single
Pole
Circuits a
Load Center
Box, Interior and Cover b
Max.
Tandem
Circuit
Breakers
Main Wire Size
AWG/kcmil
$ Price
(DE3C)
Cat. No.
Al
Cu
Equipment Ground Bar Kit
(Order Separately)
Cat. No.
$ Price
Box No.
See
Page 1-17
Main Lugs—10 kA Short Circuit Current Rating Order HOM Circuit Breakers (See page 1-14)
Factory-installed Fixed Main Lugs
70 A
100 A
125 A
2
6
4
4
12
8
2
6
4
HOM24L70F/Sdc
HOM612L100F/Sce
HOM48L125GC
59.00
78.00
86.00
12–3
14–4
8–1
PK3GTA1
PK7GTA
PK7GTA Factory-included
11.40
11.70
2
4
21
12–2/0
14–2/0
132.00
174.00
260.00
237.00
360.00
6–2/0
6–1
6–1
6–1/0
6–1/0
6–2/0
PK9GTA
PK15GTA
PK15GTA
PK18GTA
PK23GTA
13.40
17.10
17.10
18.80
21.30
6
6
8
8
10
420.00
618.00
732.00
902.00
4–300
4–250
PK23GTA
PK27GTA
PK27GTA
PK27GTA
21.30
33.80
33.80
33.80
10
12
12
25
150.00
204.00
288.00
344.00
6-2/0
6–1
6–1
6–1/0
6–1/0
PK15GTAL Included
PK15GTAL Included
PK15GTAL Included
PK15GTAL Included
6
6
8
8
4–250
PK15GTAL & PK15GTA Included
PK15GTAL Included
PK15GTAL Included
PK15GTAL & PK15GTA Included
PK15GTAL & PK15GTA Included
10
9
9
12
12
Convertible Mains—Factory-installed Main Lugs
QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-16)
125 A
8
12
16
20
30
16
24
32
40
60
8
12
16
20
30
HOM816L125PC
HOM1224L125PC
HOM1632L125PC
HOM2040L125PC
HOM3060L125PC
Convertible Mains—Factory-installed Main Lugs
QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-16)
HOM3060L225PC
30
60
30
HOM4080L225PC
40
80
40
225 A
42
84
42
HOM4284L225PC
HOM60120L225PC f
60
120
60
Convertible Mains—Factory-installed Main Lugs—Ground Bar Included
QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-16)
125 A
I
N
D
O
O
R
8
12
20
24
16
24
40
48
8
12
20
24
HOM816L125PGC
HOM1224L125PGC
HOM2040L125PGC
HOM2448L125PGC
Convertible Mains—Factory-installed Main Lugs—Ground Bar Included
QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-16)
225 A
30
16
20
40
42
60
32
40
80
84
30
16
20
40
42
HOM3060L225PGC
HOM1632L225PGC
HOM2040L225PGC
HOM4080L225PGC
HOM4284L225PGC
618.00
357.00
417.00
839.00
804.00
4–300
Main Circuit Breaker—22 kA Short Circuit Current Rating
Convertible Mains—Factory-installed Main Circuit Breaker
QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 1-16)
100 A
125 A
8
12
20
24
30
24
30
16
24
40
48
60
48
60
8
12
20
24
30
24
30
HOM816M100PC
HOM1224M100PC
HOM2040M100PC
HOM2448M100PC
HOM3060M100PC
HOM2448M125PC
HOM3060M125PC
315.00
384.00
396.00
513.00
672.00
710.00
812.00
6–1
6–2/0
6–1
6–2/0
6–2/0
6–2/0
6–3
6–1
6–3
6–1/0
6–2/0
6–1/0
6–2/0
PK9GTA
PK15GTA
PK18GTA
PK23GTA
PK23GTA
PK23GTA
PK23GTA
13.40
17.10
18.80
21.30
21.30
21.30
21.30
5
6
7
8
10
8
10
PK23GTA
21.30
10
PK18GTA
PK23GTA
PK27GTA
PK27GTA
PK27GTA
PK27GTA
18.80
21.30
33.80
33.80
33.80
33.80
9
10
12
12
25
12
Convertible Mains—Factory-installed Main Circuit Breaker
QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 1-16)
150 A
30
60
30
HOM3060M150PC
776.00
4–250
HOM2040M200PC
711.00
20
40
20
30
60
30
HOM3060M200PC
798.00
HOM4080M200PC
1019.00
4–250
40
80
40
200 A
42
84
42
HOM4284M200PC
1313.00
HOM60120M200C f
1876.00
60
120
60
225 A
42
84
42
HOM4284M225PC
1116.00
4–300
4–250
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a
Maximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers.
b
C at end of catalog number indicates combination flush/surface cover included with device.
c
F/S at end of catalog number indicates to order F for flush device or S for surface device. The cover does not have a door.
d
HOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire.
e
70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker.
f
Door kit available separately. Order QOCDK60 $237.00.
© 2012 Schneider Electric
All Rights Reserved
DE3A
DE3C
Discount
Schedule
1-15
LOAD CENTERS
Mains
Rating
Convertible Main Load Centers (Accepts Only HOM Plug-On Circuit Breakers.)
1
Table 1.46:
Homeline™ Load
Centers
Rainproof, 1Ø, Main Lugs and Main Circuit Breakers
Class 1170 / Refer to Catalog 1100CT0501
www.schneider-electric.us
1
1Ø3W—120/240 Vac—UL Listed
Table 1.47:
Convertible Main Load Centers (Accepts Only HOM Plug-On Circuit Breakers.)
Mains Rating
Spaces
Max. Single
Pole
Circuits a
Max. Tandem
Circuit
Breakers
Load Center
Box, Interior and Cover
Cat. No. (DE3C)
Main Wire Size
AWG/kcmil
$ Price
Al
Cu
Equipment Ground Bar Kit
(Order Separately)
Cat. No. (DE3A)
$ Price
Box No.
See
Page 1-18
Main Lugs—10 kA Short Circuit Current Rating
LOAD CENTERS
Factory-installed Fixed Main Lugs, 10 kA Short Circuit Current Rating
70 A
100 A
125 A
2
6
4
4
12
8
2
6
4
HOM24L70RBb
HOM612L100RBf
HOM48L125GRB
111.00
129.00
137.00
12–3
14–4
8–1
12–2/0
14–2/0
PK4GTA
10.80
PK7GTA
11.70
PK7GTA Factory-included
1R
2R
15R
PK9GTA
PK15GTA
PK18GTA
PK23GTA
13.40
17.10
18.80
21.30
3R
3R
4R
6R
PK9GTA
PK15GTA
PK18GTA
PK23GTA
PK27GTA
PK27GTA
13.40
17.10
18.80
21.30
33.80
33.80
5R
6R
6R
7R
14R
14R
Convertible Mains with Factory-installed Main Lugs c, QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See Below)
R
A
I
N
P
R
O
O
F
125 A
8
12
20
24
16
24
40
48
8
12
20
24
HOM816L125PRB
HOM1224L125PRB
HOM2040L125PRB
HOM2448L125PRB
248.00
278.00
383.00
390.00
6–2/0
6–1
Convertible Mains with Factory-installed Main Lugs c, QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See Below)
225 A
12
16
20
30
40
42
12
32
40
60
80
84
0
16
20
30
40
42
HOM12L225PRB
HOM1632L225PRB
HOM2040L225PRB
HOM3060L225PRB
HOM4080L225PRB
HOM4284L225PRB
423.00
510.00
560.00
759.00
1139.00
1092.00
4–300
4–250
Main Circuit Breaker—22 kA Short Circuit Current Rating
R
A
I
N
P
R
O
O
F
Convertible Mains with Factory-Installed Main Circuit Breaker, QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) d
HOM816M100PRB
429.00
PK9GTA
13.40
3R
8
16
8
12
24
12
6–2/0
HOM1224M100PRB
416.00
PK15GTA
17.10
3R
100 A
6–1
20
40
20
HOM2040M100PRB
531.00
PK18GTA
18.80
4R
HOM816M125PRB
716.00
PK9GTA
13.40
3R
8
16
8
6–2/0
125 A
6–1
HOM2448M125PRB
858.00
PK23GTA
21.30
6R
24
48
24
Convertible Mains with Factory-installed Main Circuit Breaker, QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below)
150 A
30
60
30
HOM3060M150PRB
978.00
4–250
PK23GTA
21.30
7R
HOM12M200PRB
795.00
PK9GTA
13.40
5R
12
12
0
20
40
20
HOM2040M200PRB
872.00
PK18GTA
18.80
6R
4–250
200 A
HOM3060M200PRB
1152.00
PK23GTA
21.30
7R
30
60
30
HOM4080M200PRB
1596.00
PK27GTA
33.80
14R
40
80
40
Convertible Mains with Factory-installed Main Circuit Breaker with Feed-thru Lugs,
QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) c
150 A
8
16
8
HOM816M150PFTRB
785.00
4–250
PK15GTA
35.00
6R
200 A
8
16
8
HOM816M200PFTRB
785.00
4–250
PK15GTA
35.00
6R
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a
Maximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers.
b
HOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire.
c
Side hinge door device allow 1-1/4 in. on left side for door to open.
d
22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current.
e
Rated 200 A when using copper wire. Reference NEC® Table 310.15(B)(6) when using Al wire.
f
70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker.
1Ø, Field-Installed Mains Kits
Table 1.48:
Main Lug Kit
QOL125
QOL225
1-16
Field-Installed
Main Type
For Convertible Load Centers Only
Main g
Use on Convertible Load
$ Price
Lug Wire Size j
Cat. No.
Ampere Rating
Center with Mains Rating
(DE3A)
AWG/kcmil
125 A
100–125 A
QOL125
44.10
6–2/0 Al or Cu
Main Lugs h
—
225 A
150–225 A
QOL225
104.00
6–300 Al or Cu
QOM50VH
140.00
50 A
100–125 A
60 A
100–125 A
QOM60VH
140.00
QOM70VH
140.00
70 A
100–125 A
QOM80VH
201.00
80 A
100–125 A
12–2/0 Al or Cu
QOM1
90 A
100–125 A
QOM90VH
201.00
QOM100VH
201.00
100 A
100–125 A
110 A
125 A
QOM110VH
468.00
Main Circuit
Breaker i
QOM125VH
468.00
125 A
125 A
100 A
150–225 A
QOM2100VH
468.00
QOM2125VH
468.00
125 A
150–225 A
150 A
150–225 A
QOM2150VH
468.00
QOM2k
4–300 Al or Cu
QOM2175VH
468.00
175 A
200–225 A
200 A
200–225 A
QOM2200VH
468.00
QOM2225VH
468.00
225 A
225 A
g
Do not exceed the load center mains rating.
h
If main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from page 1-13.
i
22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with
up to 22 kA available fault current.
j
Wire range listed for main device kits is the wire range of that device. To find out maximum wire size permitted in a particular load center per UL, see
pages 1-5 through 1-11 under Main Wire Size.
k
Add suffix 1021 for 120, 208, 240 Vac shunt trip.
Frame Size
DE3A
DE3C
Discount
Schedule
© 2012 Schneider Electric
All Rights Reserved
QO™ and Homeline™ Load Centers
Indoor, Dimensions and Knockouts
Class 1130, 1170 / Refer to Catalog 1100CT0501
ZZZVFKQHLGHUHOHFWULFXV
Indoor Knockout Information and Enclosure Dimensions
A
A,B,C,D
A,B,C
A,B,C
A
Table 1.49:
A,B,C
A
Enclosure Dimensions
A,B,C
A,B
Box 3
Box 1
A
A,B
B,C,D,E
B,C,D,E
C,D,E,F,G
A A,B
B,C,D,E
C,D,E,F
B,C,D,E
B,C,D,E
A
A,B
A
A
B,C,D,E
B,C,D,E
Dimensions
H
D
in.
mm
in.
mm
in.
mm
1
2
3
4
5
6
7
8
9
10
11
12
13
3.81
4.81
4.81
8.88
14.25
14.25
14.25
14.25
14.25
14.25
14.25
14.25
5.88
97
122
122
226
362
362
362
362
362
362
362
362
149
6.72
9.30
9.30
12.57
14.92
17.92
20.92
26.04
29.86
33.78
37.98
39.37
13.12
171
236
236
319
379
455
531
661
758
858
965
1000
333
3.00
3.19
3.19
3.80
3.75
3.75
3.75
3.75
3.75
3.75
3.75
3.75
3.38
76
81
81
97
95
95
95
95
95
95
95
95
86
W
H
D
Box
No.
in.
mm
in.
mm
in.
mm
14
15
16
17
18
19
20
21
22
23
24
25
14.25
20.00
20.00
20.00
5.88
7.56
9.62
8.88
8.55
14.25
14.25
14.25
362
508
508
508
149
192
244
226
217
362
362
362
20.92
50.00
62.00
53.00
16.12
23.12
26.12
14.80
23.92
29.86
43.15
48.50
531
1270
1727
1346
409
587
663
376
608
758
1096
1235
3.75
5.75
5.75
5.75
3.38
4.25
4.75
3.80
3.95
3.75
3.75
3.75
95
146
146
146
86
108
121
97
100
95
95
95
A,B,C,D
B,C,D,E
Box 4
Table 1.50:
Box 5
Knockout Information
Knockouts
B,C,D,E
B,C,D,E
C,D,E,F,G
C,D,E,F,G
A
B
C
Conduit
Size
1/2
3/4
1
B,C,D,E
C,D,E,F,G
D
E
1-1/4 1-1/2
F
G
H
I
2
2-1/2
3
3-1/2
C,D,E,F,G
B,C,D,E
C,D,E,F
A A,B
A A,B
D,E,F,G
B,C,D,E
C,D,E,F
A A,B
Symbol
B,C,D,E
C,D,E,F
A A,B
B,C,D,E
D,E,F,G
C,D,E,F
B,C
C,D,E,F,G
D,E,F,G
A A,B
B,C,D,E
D,E,F,G
B,C
A,B
B,C,D,E
C,D,E,F
A,B
A,B
A
A,B
A
A
A
A,B,C,D
A,B,C,D
B,C,D,E
A,B,C,D
C,D,E,F
D,E,F,G
A,B,C,D
Box 9
Box 7
B,C,D,E
C,D,E,F
C,D,E,F,G
D,E,F,G
A A,B
B,C,D,E
D,E,F,G
B,C,D,E
B,C,D,E
C,D,E,F,G
D,E,F,G
B,C
A,B,C,D
C,D,E,F
D,E,F,G
Box 10
A A,B
C,D,E,F
D,E,F,G
A,B
D,E,F,G,H
D,E,F,G,H,I
C,D,E,F
B,C
A
A,B
A,B,C
D,E,F,G
A,B
B,C,D,E
A,B
C,D,E,F
C,D,E,F
A,B,C,D
A
A,B
A
A
A,B,C,D
C,D,E,F
D,E,F,G
A,B,C,D
B,C,D,E
A,B,C,D
B,C,D,E
C,D,E,F
Box 14
Box 13
Box 11
A
C,D,E,F
D,E,F,G
C,D,E,F
D,E,F,G
A,B
B,C,D,E
D,E,F,G
B,C
C,D,E,F E,F,G,H
A,B,C,D
A,B,C
D,E,F,G
A,B
D,E,F,G
A
B,C,D,E
A,B
B,C,D,E
B,C,D,E
A
A
A,B
B,C,D,E
B,C,D,E
C,D,E,F
B,C,D,E
D,E,F,G
A,B,C,D
C,D,E,F
Box 19
© 2012 Schneider Electric
All Rights Reserved
1-17
LOAD CENTERS
A
W
Box
No.
1
Dimensions
A
QO™ Load Centers
Indoor, 1Ø, Main Lugs and Main Breaker
Class 736, 1130 / Refer to Catalog 1100CT0501
www.schneider-electric.us
QO Plug-on Neutral Load Centers and CAFI Breakers connect are engineered for a quick Plug-on Neutral
connection on every unit.
$ Price Load Center Box and Interior
Max.
Max.
1P
Tandem (Interior,
Spaces
Box &
Circuits Breakers
Cover)
Cat. No.
$ Price
Equipment
Main Wire Ground
Bar Kit Box No.
Size
(Order Separately
See
AWG/kcmil
If Priced)
Page
1-17
$ Price
Al/Cu
Cat. No. $ Price
Indoor Cover with Door
(Order Separately)
Flush
Cat. No.
Surface
Cat No.
Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating — Copper Bus
QOM1 Main Frame Size, Convertible to Main Circuit Breaker
125 A
24
24
572.00
0
534.00 QOC24UF QOC24US
QO124L125PG
37.70
6–2/0
PK15GTA
Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating — Copper Bus
QOM2 Main Frame Size, Convertible to Main Circuit Breaker
597.00 QOC30UF QOC30US 87.00
6–250 PK23GTA, LK100AN
200 A
30
30
0
684.00 QO130L200PG
907.00 QOC42UF QOC42US 111.00
(2) PK15GTA
42
42
0
1018.00 QO142L225PG
6–300
225 A
54
54
0
1356.00 QO154L225PG 1177.00 QOC54UF
—
179.00
PK23GTA, LK100AN
Convertible Mains — Factory-Installed Main Circuit Breaker — 22 kA Short Circuit Current Rating — Copper Bus
QOM1 Main Circuit Breaker Frame Size, Convertible to Main Lugs or Lower Amperage Main Circuit Breaker
I
N
D
O
O
R 100 A
QO154M200P
24
24
828.70
0
791.00 QOC24UF QOC24US
QO124M100P
37.70
6–2/0
Convertible Mains — Factory-Installed Main Circuit Breaker — 22 kA Short Circuit Current Rating — Copper Bus
QOM2 Main Circuit Breaker Frame Size, Convertible to Main Lugs or Lower Amperage Main Circuit Breaker
QO130M200P
1043.00 QOC30UF QOC30US 87.00
30
30
0
1130.00
QO142M200P
1249.00 QOC42UF QOC42US 111.00
42
42
0
1360.00
4–250
200 A
54
54
0
1618.00
QO154M200P
1439.00 QOC54UF
—
179.00
—
267.00
60
60
0
1916.00 QO160M200PCac 1916.00 QOC60UFa
Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating — Cu Bus
QOM1 Main Circuit Breaker Frame Size, Convertible to Main Circuit Breaker — Equipment Ground Bar Included
—
—
—
6–2/0
125 A
24
24
0
712.00 QO124L125PGRB 712.00
Table 1.74:
7
9
11
12
PK15GTA
17.10
7
PK18GTA
PK23GTA
PK23GTA
PK23GTA
18.80
21.30
21.30
21.30
9
11
12
24
PK15GTA
Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating — Cu Bus
QOM2 Main Circuit Breaker Frame Size, Convertible to Main Circuit Breaker — Equipment Ground Bar Included
30
30
0
856.00 QO130L200PGRB 856.00
—
—
—
6–250 PK23GTA, LK100AN
O 200 A
U 225 A
42
42
0
1500.00 QO142L225PGRB 1500.00
—
—
—
6–300
(2) PK15GTA
T
D Convertible Mains — Factory-Installed Main Circuit Breaer — 22 kA Short Circuit Current Rating — Copper Bus
O Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5),
O QOM1 Main Circuit Breaker Frame Size
R 100 A
—
—
—
6–2/0
PK15GTA 17.10
24
24
0
1144.00 QO124M100PRB 1144.00
b
Convertible Mains — Factory-Installed Main Circuit Breaer — 22 kA Short Circuit Current Rating — Copper Bus
Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5),
QOM2 Main Circuit Breaker Frame Size
150 A
30
30
0
1344.00 QO130M150PRB 1344.00
—
—
—
PK18GTA 18.80
30
30
0
1344.00 QO130M200PRB 1344.00
4–250
—
—
—
PK18GTA 21.30
200 A
—
—
—
PK23GTA 21.30
42
42
0
1659.00 QO142M200PRB 1659.00
a
Door kit available separately Order QOCDK60 $237.00.
b
All OUTDOOR devices are available FACTORY ORDER only.
c
Cover comes included with load center.
4R
6R
8R
4R
6R
6R
8R
QO Arc Fault Circuit Breakers
1P 120 Vac
1P 120 Vac
10 k AIR
22 k AIR
1 Space Required
1 Space Required
Circuit Breaker
Type
Ampere
Rating
Cat. No.
$ Price
Cat. No.
$ Price
Combination Arc-fault
Interrupter
(Pigtail Neutral)
Plug-On Neutral
Combination Arc-fault
Interrupter
15
QO115CAFI
282.00
QO115VHCAFI
534.00
20
QO120CAFI
282.00
QO120VHCAFI
534.00
15
QO115PCAFI
282.00 QO115VHPCAFI
534.00
20
QO120PCAFI
282.00 QO120VHPCAFI
534.00
QO-Dual Function Circuit Breaker
QO Combination Arc Fault and Ground Fault Circuit Interrupters (Dual Function) provide overload and short circuit
protection, plus arc fault and ground fault protection in accordance with the NEC, UL1699 and UL943.
Table 1.75:
1P
QO-DF
QO-Dual Function Arc Fault Circuit Breakersa
1P 120 Vac
Circuit Breaker Type
Combination Arc-fault and
Ground Fault Circuit Interrupter
(Pigtail Neutral)
Plug-On Neutral Combination
Arc-fault and Ground Fault
Circuit Interrupter
Ampere
Rating
15
1P 120 Vac
10 k AIR
22 k AIR
1 Space Required
1 Space Required
Cat. No.
QO115DF
$ Price
326.00
Cat. No.
QO115VHDF
$ Price
578.00
20
QO120DF
326.00
QO120VHDF
578.00
15
QO115PDF
326.00
QO115VHPDF
578.00
20
QO120PDF
326.00
QO120VHPDF
578.00
Schneider Electric
1601 Mercer Road
Lexington, KY 40511 USA
(1-888-778-2733)
www.schneider-electric.us
Document No. 0100CT1401
July 2014
© 2012 Schneider Electric
All Rights Reserved
DE2A
DE3A
Discount
Schedule
LOAD CENTERS
Mains
Rating
QO Plug-on Neutral CAFI Load Center (accepts QO Circuit Breakers only)
1-27
1
Table 1.73: