QO™ Miniature Circuit Breakers QO Plug-On Circuit Breakers Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801 www.schneider-electric.us QO Arc-Fault Circuit Breaker QO-SWN QO arc-fault circuit breakers provide protection for Series and Parallel Type Arcing as required by the NEC and local code adoption, and comply with UL1699. Switch Neutral Common Trip 2008 NEC® 514.11 1P QO-DF One- Pole 1P 120 Vac 1P 120 Vac 10 k AIR 22 k AIR Circuit Breaker Type Ampere Rating 1 Space Required 1 Space Required Cat. No. $ Price Cat. No. $ Price Combination Arc-fault QO115CAFI 282.00 QO115VHCAFI 534.00 15 Interrupter QO120CAFI 282.00 QO120VHCAFI 534.00 20 (Pigtail Neutral) Plug-On Neutral 15 QO115PCAFI 282.00 QO115VHPCAFI 534.00 Combination Arc-fault 20 QO120PCAFI 282.00 QO120VHPCAFI 534.00 Interrupter Two- Pole 2P 120/240 Vac 2P 120/240 Vac 10 k AIR 22 k AIR Ampere Circuit Breaker Type Rating 2 Space Required 2 Space Required Cat. No. $ Price Cat. No. $ Price Combination Arc-fault 15 QO215CAFIf 636.00 QO215VHCAFIf 1068.00 Interrupter 20 QO220CAFIf 636.00 QO220VHCAFIf 1068.00 (Pigtail Neutral) QO Combination Arc Fault and Ground Fault Circuit Interrupters (Dual Function) provide overload and short circuit protection, plus arc fault and ground fault protection in accordance with the NEC, UL1699 and UL943. Table 1.7: Combination Arc-fault and Ground Fault Circuit Interrupter (Pigtail Neutral) Plug-On Neutral Combination Arc-fault and Ground Fault Circuit Interrupter 1P 120 Vac 10 k AIR 1 Space Required Cat. No. $ Price 1P 120 Vac 22 k AIR 1 Space Required Cat. No. $ Price 15 QO115DF 326.00 QO115VHDF 578.00 20 QO120DF 326.00 QO120VHDF 578.00 15 QO115PDF 326.00 QO115VHPDF 578.00 20 QO120PDF 326.00 QO120VHPDF 578.00 HID circuit breakers are for use on circuits feeding fluorescent and high intensity discharge (HID) lighting systems such as mercury vapor, metal halide, or high pressure sodium. These circuit breakers are physically interchangeable with QO circuit breakers. Table 1.11: Ampere Ratingc 15 20 25 30 40 50 2P QO-GFI Table 1.8: QO-GFI Circuit Breakers Ampere Ratingc Qwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter 2P Common Trip 3P Common Trip 1P 120 Vac 120/240 Vac 208Y/120 Vac 10 k AIR 22 k AIR 10 k AIR 10 k AIR 3 Spaces 1 Space Required 1 Space Required 2 Spaces Required Required $ $ $ $ Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price 15 QO115GFI 233. QO115VHGFI 482. QO215GFI 413. QO315GFI 791. 20 QO120GFI 233. QO120VHGFI 482. QO220GFI 413. QO320GFI 791. 25 QO125GFI 233. QO125VHGFI 482. QO225GFI 413. — — 30 QO130GFI 233. QO130VHGFI 482. QO230GFI 413. QO330GFI 791. 40 — — — — QO240GFI 413. QO340GFI 791. 50 — — — — QO250GFI 413. QO350GFI 791. — — 60 — — — — QO260GFId 413. QO-EPD/EPE QO-EPD/EPE circuit breakers provide overload and short circuit protection combined with Class B ground fault protection. They are designed to provide ground fault protection of equipment at a 30 mA level (EPD) or 100 mA level (EPE). They are not designed to protect people from electrical shock. Ampere Ratingc Table 1.9: QO 1P With Shunt Trip © 2012 Schneider Electric All Rights Reserved 1P 120 Vac 10 k AIR 1 Space Required QO-EPD Circuit Breakers 2P Common Trip 120/240 Vac 10 k AIR 3P Common Trip 240 Vac 10 k AIR 2 Spaces Required 3 Spaces Required $ $ $ Cat. No. Cat. No. Cat. No. Price Price Price 15 QO115EPD 410. QO215EPD 660. QO315EPDe 1077. 20 QO120EPD 410. QO220EPD 660. QO320EPDe 1077. — — 25 QO125EPD 410. QO225EPD 660. 30 QO130EPD 410. QO230EPD 660. QO330EPDe 1077. 40 — — QO240EPD 660. QO340EPDe 1077. 50 — — QO250EPD 660. QO350EPDe 1077. — — 60 — — QO260EPDd 660. DE2A 10 k AIR 1 Space Required Cat. No. $ Price 38.10 QO115HIDb b 38.10 QO120HID QO125HID 38.10 QO130HID 38.10 QO140HID 38.10 QO150HID 38.10 2P Common Trip 120/240 Vac 10 k AIR 2 Spaces Required Cat. No. $ Price QO215HID 87.00 QO220HID 87.00 QO225HID 87.00 QO230HID 87.00 QO240HID 87.00 QO250HID 87.00 3P Common Trip 240 Vac 10 k AIR 3 Spaces Required Cat. No. $ Price QO315HID 300.00 QO320HID 300.00 QO325HID 300.00 QO330HID 300.00 — — — — QO-HM High magnetic trip circuit breakers are recommended for applications where high initial inrush may occur and for individual dimmer applications. Table 1.12: QO-HM Circuit Breakers 120 Vac—10 k AIR 1P Ampere Ratingc 15 A 20 A ™ 1P QO-GFI QO-HID Circuit Breakers NOTE: QO-K Circuit Breakers are on page 1-27. QO-GFI Qwik-Gard circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 mA or more, for people protection. Do not connect to more than 250 feet of load conductor for the total one-way run to prevent nuisance tripping. 3 Wire 120/240 Vac 10 k AIR 3 Spaces Required Cat. No. $ Price QO310SWN 143.00 QO315SWN 143.00 QO320SWN 143.00 QO325SWN 143.00 QO330SWN 143.00 QO340SWN 143.00 QO350SWN 143.00 QO-HID QO-Dual Function Arc Fault Circuit Breakersa Ampere Circuit Breaker Type Rating Two-wire QO-SWN 10 15 20 25 30 40 50 1P 120/240 Vac QO-Dual Function Circuit Breaker Three-wire QO-SWN 2 Wire 120 Vac 10 k AIR 2 Spaces Required Cat. No. $ Price QO210SWN 95.00 QO215SWN 95.00 QO220SWN 95.00 QO225SWN 95.00 QO230SWN 95.00 QO240SWN 95.00 QO250SWN 95.00 Ampere Ratingc Cat. No QO115HMab QO120HMab $ Price 30.60 30.60 Non-automatic (Standard) Miniature Switches Miniature non-automatic switches have the same physical packaging as miniature circuit breakers, but open only when the handle is switched to the OFF position. Non-automatic switches provide no overcurrent protection or short circuit protection. They must not be used on systems that have an available fault current greater than the values listed in the table. Non-automatic switches are UL Listed per UL 1087 and are CSA certified. Table 1.13: QO Non-Automatic Miniature Switches, 240 Vac 10 kA Ampere Rating 60 100 2P Cat. No. QO200 QO2000 3P $ Price 70.00 200.00 Cat. No. QO300 QO3000 $ Price 248.00 366.00 UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. b UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. c 10–30 A circuit breakers are suitable for use with 60oC or 75oC conductors. 35–60 A circuit breakers are suitable for use with 75oC conductors. d Suitable only for feeding 240 Vac and 208 Vac two-wire loads. Does not contain load neutral connection. e See note in Instruction Bulletin when using in an enclosure with a QO403 or QON prefix. f For 120/240 V only, not for 208Y/120 V. Interrupting Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-2 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-12 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-54 a $ Cat. No. Price QO315EPEe 1077. QO320EPEe 1077. — — QO330EPEe 1077. QO340EPEe 1077. QO350EPEe 1077. — — Discount Schedule 1-3 LOAD CENTERS 1P QO-CAFI QO Arc Fault Circuit Breakersa QO-SWN Circuit Breakers 1 Table 1.6: Table 1.10: QO™ Load Centers 1Ø, Special Applications Class 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us 1 1Ø2W—120Vac—1Ø3W—120/240 Vac—UL Listed Table 1.26: QO Special Application (Accepts Only QO Plug-On Circuit Breakers.) Short Circuit Current Rating Mains Rating Max. 1P Circuits a Spaces Load Center b Box, Interior, and Cover Equipment Ground Bar Kit (Order Separately) Max. Tandem Circuit Breakers Cat. No. 0 2 QO2L30TTSd QO24L50TTSe 51.00 78.00 Factory-installed 2 QO35FM30TTF/S 83.00 Factory-installed 2 6 6 8 8 QO24L70TSe QO612L100TF/Sg QO612L100DTF/Sg QO816L100TF/Sg QO816L100DTF/Sg 78.00 86.00 101.00 137.00 159.00 Factory Installed LOAD CENTERS Manufactured Housing: 1Ø2W 120 Vac—Main Lugs Only—CSA Certified 30 Ac 10 kA 2 2 4 50 A 10 kA 2 $ Price Cat. No. Main Wire Size AWG/kcmil Al Cu Box No. See Page 1-17 12–10 — 14–10 14–6 1 2 $ Price 1Ø2W 120 Vac—Main Circuit Breaker—CSA Certified 30 A 10 kA 3 5 1Ø3W 120/240 Vac—Main Lugs Only—CSA Certified 70 A 10 kA 2 4 6 12 6 12 100 A 10 kA 8 16 8 16 3 f 12–3 14–4 2 4 4 4 4 4–1 Load Center with Cover: 1Ø3W 120/240 Vac—UL Listed Complete QO Load Center—Box, Interior and Combination Cover in One Package Convertible Mains—Factory-Installed Main Lugs i—QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5)—Copper Bus I N D O O R 65 kA 65 kA 65 kA 12 12 20 0 12 0 6–2/0 6–2/0 6–2/0 6 6 7 6–250 6–250 9 9 13.40 17.10 15.80 17.10 18.80 4–1/0 4–1/0 4–1/0 4–1/0 6–2/0 5 5 6 6 8 Convertible Mains—Factory-Installed Main Circuit Breaker— QOM2 Main Frame Size—Convertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)—Copper Bus j QO12030M150C 843.00 PK18GTA 18.80 22 kA 20 30 10 150 A QO130M150C 870.00 PK18GTA 18.80 22 kA 30 30 0 QO12040M200C 843.00 PK23GTA 21.30 22 kA 20 40 20 22 kA 30 30 0 QO130M200C 896.00 PK18GTA 18.80 200 A QO13040M200C 974.00 PK23GTA 21.30 22 kA 30 40 10 22 kA 40 40 0 QO140M200C 1137.00 PK23GTA 21.30 4–250 4–250 4–250 4–250 4–250 4–250 9 9 9 9 9 10 125 A 12 24 20 QO112L125GC QO11224L125GC QO120L125GC 188.00 249.00 284.00 PK12GTA Incl. PK15GTA Incl. PK15GTA Incl. Convertible Mains—Factory-Installed Main Lugs i—QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5)—Copper Bus 150 A 65 kA 30 30 0 QO130L150TC 452.00 PK23GTA, LK100AN Installed 200 A 65 kA 30 40 10 QO13040L200GC 575.00 PK23GTA, LK100AN Incl. Convertible Mains—Factory-Installed Main Circuit Breaker— QOM1 Main Frame Size—Convertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)—Copper Bus j 22 kA 22 kA 22 kA 22 kA 22 kA 100 A 125 A 12 12 16 20 32 12 20 16 20 32 0 8 0 0 0 QO112M100C QO11220M100C QO116M100C QO120M100C QO132M125C 351.00 413.00 395.00 446.00 1041.00 PK9GTA PK15GTA PK12GTA PK15GTA PK18GTA Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b Order F for flush device or S for surface device. c Mains rating 25 A when Al wire is used. d Will not accept Qwik-Gard™ QO-GFI or QO-AFI circuit breaker. e Use 10 AWG maximum size wire for GFI and AFI circuit breakers. f Main circuit breaker is a field-installed standard QO single pole circuit breaker. Order separately from page 1-2. g 70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker. h UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. i UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. j 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22,000 A available fault current. Table 1.27: Service Upgrade Load Centers: 1Ø3W 120/240Vac—UL Listed Load Center with Removable End Walls Convertible Mains—Factory-Installed Main Breaker—22KA QOM2 Main Frame Size—Convertible to Main Lugs (See page1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)j I N D O O R k l m Mains Rating Spaces Max. 1P Circuitsa Max. Tandem Circuit Breakers $ Price (Interior, Box and Cover) Load Center Box and Interior Extra Long Cover with Door (Order Separately) Cat. No. Flush Cat. No. $ Price Surface Cat. No. 30 60 30 959.00 HOM3060M200PCEPk 959.00 HOMC30UFL 200 A 40 40 0 1137.00 QO140M200EPm 1137.00 QOC40UFL Ships with standard length cover Blank Endwall Plates (4) Available Order: EWPLATE $36.00 Copper Bus, order cover separately QOC40UF/S or QOC40UFL Table 1.28: — — Main Wire Size Equipment Ground Bar AWG / kcmil Kit (Order Separately) $ Price 111.00 111.00 Al Cu 4-250 Cat. No PK23GTA PK23GTA Box No. See Page 1–17 $ Price 21.30 21.30 10 10 Auxiliary Gutter UL Listed for use with standard 1Ø and 3Ø load centers for riser applicationsn. For auxiliary gutter-load center compatibility, see catalog number 1100CT0501 Cat. No. n o $ Price SDAG26 338.00 One tap kit required for each riser wire. When used with B300 bolt-on hubs. Table 1.29: Cover Conduit Riser Size Width Height Depth Flush 1-3/4, 2, 2-1/2 or o3 13.50 26.12 3.75 Tap Kits 120/240 Vac—UL Listed for use with Auxiliary Gutter SDAG26 Cat. N0. $ Price Use with Auxiliary Gutter Cat. No. SDGT30020 SDGT300300 81.00 120.00 SDAG26 SDAG26 SDGT300C10C 49.70 SDAG26 SDGT300C300C 70.00 SDAG26 QOGL20 Grounding Terminals 40.70 SDAG26 1-10 Riser Wire Lug Type Mechanical (Included) Mechanical (Included) Anderson VCEL030516H1 (Not included) Anderson VCEL030516H1 (Not included) Mechanical (Included) DE3A Discount Schedule Tap Off Wire Al/Cu Wire Size (2) 6 AWG–300 kcmil (2) 6 AWG–300 kcmil (2) 4 AWG–300 kcmil (2) 4 AWG–300 kcmil (2) 6–2/0 AWG Lug Type Mechanical (Included) Mechanical (Included) Anderson VCEL02114S1 (Not Included) Anderson VCEL030516H1 (Not included) — Al/Cu Wire Size (1) 6–2/0 AWG (1) 6 AWG–300 kcmil (1) 8–1/0 AWG (1) 4 AWG–300 kcmil — © 2012 Schneider Electric All Rights Reserved QO™ and Homeline™ Load Centers and Circuit Breakers 1Ø, Value Packs and Riser Panels Class 1130, 1170 / Refer to Catalog 1100CT0501 www.schneider-electric.us 1Ø3W—120/240 Vac—UL Listed I N D O O R R A I N P R O O F Value Packs Contains Complete Load Center (Box, Interior and Cover) with Selected Branch Circuit Breaker Load Center Box, Interior, Cover and Branch Circuit Breakers Cat. No. Included Load Center/Circuit Breakers $ Price Equipment Ground Bar Kit (Order Separately) Cat. No. $ Price Main Wire Size AWG/kcmil Al/Cu QO (Accepts Only QO Plug-On Circuit Breakers) QO—Copper Bus Convertible Mains—Factory-Installed Main Circuit Breaker, 10 kA Short Circuit Current Rating Convertible appropriate QOM 22 kA Short Circuit Current Rating Main Circuit Breaker (See page 1-16) 125 A 24 24 0 QO124L125PGCVP (1) QO124L125PGC, (3) QO120, (2) QO230 793.00 PK15GTA Included 6–2/0 225 A 42 42 0 QO142L225PGCVP (1) QO142L225PGC, (3) QO120, (2) QO230 1239.00 (2) PK15GTA Included 6–300 Convertible Mains—Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating Convertible appropriate to Main Lugs (See page 1-6) or QOM Main Circit Breaker (See page 1-5) 24 0 QO124M100PCVP (1) QO124M100PC, (3) QO120, (2) QO230 1050.00 PK15GTA 17.10 6–2/0 100 A 24 32 32 0 QO32M100VP (1) QO132M100C, (3) QO120, (2) QO230 949.00 PK18GTA 18.80 4–2/0 30 40 10 QO3040M200VP (1) QO13040M200C, (3) QO120, (2) QO230 1195.00 PK23GTA 21.30 QO142M200PCVP (1) QO142M200PC, (3) QO120, (2) QO230 1581.00 PK23GTA 21.30 200 A 42 42 0 4–250 42 42 0 QO142M200PCAFVP (1) QO142M200PC, (3) QO120, (2) QO230, (3) QO115PCAFI 2427.00 PK23GTA 21.30 Homeline (Accepts Only HOM Plug-On Circuit Breakers) Convertible Mains—Factory-Installed Main Lugs, 10 kA Short Circuit Current Rating Convertible to appropriate QOM 22 kA Short Circuit Current Rating Main Circuit Breaker (See page 1-16) HOM1224L125PGCVP (1) HOM1224L125PGC, (2) HOM120 309.00 PK15GTAL Included 6–2/0 6–1 125 12 24 12 PK15GTAL & HOM3060L225PGCVP (1) HOM3060L225PGC, (3) HOM120, (2) HOM230 677.90 4–300 4–250 225 A 30 60 30 PK15GTA Incl. Convertible Mains—Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating Convertible appropriate to Main Lugs or Main Circuit Breaker (See page 1-16) HOM2040M100PCVP (1) HOM2040M100PC, (2) HOM120, (1) HOM230 528.00 PK18GTA 18.80 6–1 6–3 20 40 20 HOM2040M100PC1AVP (1) HOM2040M100PC, (2) HOM120, (1) HOM230, (1) HOM115PCAFI 855.00 PK18GTA 18.80 6–1 6–3 40 20 100 A 20 24 48 24 HOM2448M100PCVP (1) HOM2448M100PC, (3) HOM120, (2) HOM230 713.00 PK23GTA 21.30 6–2/0 6–1/0 150 A 30 60 30 HOM3060M150PCVP (1) HOM3060M150PC, (3) HOM120, (2) HOM230 1078.00 PK23GTA 21.30 4–250 20 40 20 HOM2040M200PCVP (1) HOM2040M200PC. (3) HOM120, (2) HOM230 926.00 PK18GTA 18.80 30 60 30 HOM3060M200PCVP (1) HOM3060M200PC. (3) HOM120, (2) HOM230 1091.00 PK23GTA 21.30 30 60 30 HOM3060M200PC1AVP (1) HOM3060M200PC. (3) HOM120, (2) HOM230, (1) HOM115PCAFI 1358.00 PK23GTA 21.30 HOM3060M200PCAFVP (1) HOM3060M200PC. (3) HOM120, (2) HOM230, (3) HOM115PCAFI 1814.00 PK23GTA 21.30 200 A 30 4–250 60 30 40 80 40 HOM4080M200PCVP (1) HOM4080M200PC, (3) HOM120, (2) HOM230 1218.00 PK27GTA 33.80 40 80 40 HOM4080M200PC1AVP (1) HOM4080M200PC, (3) HOM120, (2) HOM230, (1) HOM115PCAFI 1485.00 PK27GTA 33.80 40 80 40 HOM4080M200PCAFVP (1) HOM4080M200PC, (3) HOM120, (2) HOM230, (3) HOM115PCAFI 2288.00 PK27GTA 33.80 Homeline (Accepts Only HOM Plug-On Circuit Breakers) Convertible Mains—Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating Convertible to Main Lugs or Lower Amperage QOM2 Main Circuit Breaker (See page 1-16) 125 A 12 24 12 HOM1224M125PRBVP (1) HOM1224M125PRB, (3) HOM120, (2) HOM230 850.00 PK23GTA 21.30 200 A 30 60 30 HOM3060M200PRBVP (1) HOM3060M200PRB, (3) HOM120, (2) HOM230 1351.00 PK23GTA 21.30 6–2/0 6–1 4–250 Box No. See Pages 1-17, 1-18 7 12 7 8 9 11 11 6 10 7 7 8 10 9 10 10 10 12 12 12 3R 7R QO Riser Panels Table 1.31: Mains Rating I N D O O R Offset Interior for Wide Gutter—30 A Maximum Branch Circuit Breaker on left side of interiorab (Accepts Only QO Plug-On Circuit Breakers) Spaces Max. Single Pole Circuitsc Max. Tandem Circuit Breakers Load Center Box and Interior Cat. No. $ Price Load Center Cover Cat. No. $ Price Equipment Ground Bar Kit (Order Separately) Cat. No. Main Wire Size AWG/kcmil $ Price Al Cu Box No. See Page 1-17 Convertible Mains—Factory-Installed Main Lugs, 65 kA Short Circuit Current Rating Convertible to QOM1 22 kA Short Circuit Current Rating Main Circuit Breaker (See page 1-5) when used with QOC cover below—Copper Bus QO11224L125WG 338.00 QOC20UFWG 53.00 PK15GTA 17.10 14 12 24 12 6–2/0 125 A 20 30 10 QO12030L125WG 465.00 QOC20UFWG 53.00 PK15GTA 17.10 14 Convertible Mains-Factory—Installed Main Lugs, 65 kA Short Circuit Current Rating Convertible to QOM2 22 kA Short Circuit Current Rating Main Circuit Breaker (See page 1-5) when used with QOC cover below—Copper Bus 200 A 30 40 10 QO13040L200WG 701.00 QOC30UFWG 102.00 PK23GTA Convertible Mains—Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating Convertible to Main Lugs (See page 1-6) or Lower Amperage QOM2 Main Circuit Breaker (See page 1-5) when used with QOC cover below—Copper Bus QO124M200WG125d 683.00 QOC30UFWG 102.00 PK23GTA 200 A 24 24 0 21.30 4–250 23 21.30 4–250 23 Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. b UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. c Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. d Comes with 125 A main circuit breaker factory installed. Panelboard-style Covers for Riser Panels Mono-Flat™ Front available for riser panels as an alternative to standard load center cover listed above. Provides a low-profile, aesthetically pleasing solution for high-traffic areas in upscale multi-family applications. Deadfront included. Lock kit not provided. Cover NQC30FWG CANNOT be used when panel has been converted to a main circuit breaker panel. e Mains Rating of Load Center e Cat. No. 125 A NQC20FWG NQC30FWG 200 A Order catalog number PK4FL for field-installed lock kit. © 2012 Schneider Electric All Rights Reserved $ Price 117.00 180.00 DE3A Discount Schedule 1-11 LOAD CENTERS Max. Max. Tandem 1P Circuit Circuitsc Breakers 1 Mains Rating Spaces Table 1.30: Load Center Accessories QO and Homeline Load Center Accessories Class 1130, 6610 / Refer to Catalog 1100CT0501 www.schneider-electric.us QO Load Center Accessories Filler Plates Door Lock Kits Neutral / Ground Lugs Ground Bar Kits Handle Padlock Attachment a Cat. No. 50–125 A 100–225 A For padlocking main circuit breakers in convertible load centers OFF $ Price Schedule QOFP QOM1FP QOM2FP KFP Q2FP 3.60 20.30 20.30 20.30 20.30 DE3A DE3A DE3A DE3A DE3A PK8FLa 98.00 DE3A PK6FL 93.00 DE3A PK4FL LK70AN LK100AN LK125AN LK150AN 90.00 10.10 10.80 22.10 32.40 PE1A DE3A DE3A DE3A DE3A LK225AN 33.20 DE3A PK15GTAL PK18GTAL PK23GTAL PKGTAB QOM1PA QOM2PA 35.00 37.80 40.70 43.80 11.00 11.00 DE3A DE3A DE3A DE3A DE2E DE2E QO403L60NF/S does not have provisions for a field-installed lock. QOFP PKGTAB PK4FL PK6FL and PK8FL Table 1.35: Homeline Load Center Accessories Description Handle Padlock Attachment Cat. No. 50–125 A 100–225 A For padlocking main circuit breakers in convertible load center, “OFF” Fills opening in covers if twistout is removed in error Filler Plates Neutral Lugs Retaining Kit for Breakers Used as Back-fed Mains 100–125 A 150–225 A Fills main circuit breaker opening in convertible load centers Field-installed for 14–2 AWG Al or 14–4 AWG Cu wire Field-installed for 6–2/0 AWG Al/Cu wire Field-installed for 14–2/0 AWG Al/Cu wire Field-installed for 4 AWG to 300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO load center and S03 and below, 150–225 A HOM load center. Field-installed for 4 AWG–300 kcmil Al/Cu wire. Use in Series S04, 150–225 A HOM load center Secures circuit breaker to interior when used as a back-fed main. For HOM612L100F/S, RB and HOM48L125GC, GRB load centers Secures ONE circuit breaker right side of interior when used as a back-fed main For 100–125 A convertible main load centers, Series S01 and S02 Secures ONE circuit breaker right side of interior when used as a back-fed main For 150–225 A convertible main load centers, Series S01 and S02 Secures circuit breaker to interior when used as a back-fed main For 2P 150–200 A circuit breakers $ Price Schedule QOM1PA QOM2PA HOMFP QOM1FP QOM2FP LK70AN LK100AN LK125AN 11.00 11.00 3.20 20.30 20.30 10.10 10.80 22.10 DE2E DE2E DE3C DE3A DE3A DE3B DE3B DE3B DE3A LK225AN 33.20 LK225ANHOM 33.20 DE3A HOM1RK 6.50 DE3C HOM4RK2LA 14.70 DE3C HOM4RK2HA 14.70 DE3C HOM5RK 14.70 DE3C Door Lock Kit Use with convertible indoor load center covers (Series S-1) PK6FL 93.00 DE3A Replacement Cover Directory Label 1 through 42 numbered universal replacement directory label for load center covers LSDL 0.54 DE5 Circuit Identification Stickers Circuit identification stickers for use on cover directory labels to identify branch circuits PSDS 0.75 Generator Circuit Breaker Interlock Kit For use on “S” Series NEMA 1 and NEMA 3R load centers. Interlocks a QOM1 2P main circuit breaker of a load center (100–125 A) with a Homeline 2P (15–125 A) branch circuit breaker For use on “S” Series NEMA 1 and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker For use on “S2” and “S3” Series NEMA 3R QOM2 load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker © 2012 Schneider Electric All Rights Reserved DE2E DE3A DE3B DE3C DE3D DE3E DE5 PE1A Discount Schedule DE5 HOMCRBGK1 105.00 DE3D HOMCGK2 105.00 DE3D HOMRBGK2 105.00 DE3D 1-13 LOAD CENTERS Description Fills opening in covers if twistout is removed in error Fills main circuit breaker opening in convertible load center covers100–125 A Fills main circuit breaker opening in convertible load center covers150–225 A Fills main circuit breaker opening in 3Ø load center covers (S01 and S02 Series) Fills main circuit breaker opening in “Q” style 3Ø load center covers (S03 Series) Use with QO612L100DF/S, QO612L100DFCU/SCU, QO612L100DTF/S, QO816L100DF/S, QO816L100DFCU/SCU, QO816L100DTF/S, QO48M30DSGP, or QO48M60DSGP Use with convertible mains, 1Ø and 3Ø 100–225 A, and fixed mains, 3Ø 125–225 A indoor load centers Use with 300 and 400 ampere indoor load centers Field-installed for 12– 2 Al or 14–4 Cu AWG wire Field-installed for 6–2/0 Al/Cu AWG wire Field-installed for 14–2/0 Al/Cu AWG wire Field-installed for 2–3/0 Al/Cu AWG wire Field-installed for 4 AWG to 300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO load center and S03 and below, 150–225 A HOM load center. Standard PK15GTA with a 1–4/0 Al/Cu Lug Standard PK18GTA with a 1–4/0 Al/Cu Lug Standard PK23GTA with a 1–4/0 Al/Cu Lug Insulator Kit for PK7GTA through PK27GTA 1 Table 1.34: Homeline™ Circuit Breakers Plug-On Circuit Breakers Class 1170 / Refer to Catalog 1100CT0501 www.schneider-electric.us 1 The Square D Homeline circuit breakers are in a 1 in. wide format for 1-pole circuit breakers. They are designed to plug into Homeline load centers. Table 1.42: HOMT Tandem Circuit Breakers Ampere Ratinge Table 1.36: LOAD CENTERS HOM 1P 1 Space Required HOM 2P 2 Spaces Required HOMT 1P 1 Space Required HOM Ampere Rating AIR 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 110 A 125 A 150 A 175 A 200 A 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 1P—120/240 Vac Cat. No. $ Price HOM115 ab HOM120 ab HOM125 b HOM130 b — HOM140 b — HOM150 b — — — — — — — — — — Table 1.37: 2P—120/240 Vac Common Trip 26.30 26.30 26.30 26.30 — 26.30 — 26.30 — — — — — — — — — — Cat. No. $ Price HOM215 b HOM220 b HOM225 b HOM230 b HOM235 b HOM240 b HOM245 b HOM250 b HOM260 b HOM270 b HOM280 b HOM290 b HOM2100 b HOM2110 b HOM2125 b HOM2150BB bd HOM2175BB bd HOM2200BB bd 60.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 123.00 168.00 168.00 168.00 369.00 369.00 428.00 428.00 428.00 HOM-HM High magnetic trip circuit breakers are recommended for applications where high initial inrush current may occur. 1P—120/240 Vac Amperes Cat. No. HOM115HMb HOM120HMb 15 A 20 A HOM2200BB Branch Circuit Breaker 4 Spaces Required Table 1.38: 2Ps $ Price 27.60 27.60 — — — HOM-CAFI Homeline Combination Arc Fault Circuit Interrupters—Provide overload and short circuit protection, plus arc fault protection in accordance with the NEC and UL1699. Ampere Rating Circuit Breaker Type Poles 120 Vac Cat. No. $ Price HOMT Quad Circuit Breaker 2 Spaces Required HOM115CAFIbc 267.00 1 HOM120CAFIbc 267.00 1 HOM115PCAFIbc 267.00 1 HOM120PCAFIbc 267.00 15 A 2 HOM215CAFIbc 595.00 20 A 2 HOM220CAFIbc 595.00 15 A 1 20 A 15 A 20 A Table 1.43: HOMT Quad Tandem Circuit Breakers Ampere Rating e 1P Table 1.39: HOM 1P CAFI HOM-DF Homeline Combination Arc Fault and Ground Fault Circuit Interrupters (Dual Function)—Provide overload and short circuit protection, plus arc fault and ground fault protection in a single device in accordance with the NEC, UL1699 and UL943. Ampere Poles Rating 120 Vac Circuit Breaker Type Combination Arc-Fault and Ground Fault Circuit Interrupter with Pigtail Neutral Plug-On Neutral Combination Arc-Fault and Ground Fault Circuit Interrupter HOM 1P DF Table 1.40: Cat. No. $ Price 15 A 1 HOM115DFb 312.00 20 A 1 HOM120DFb 312.00 15 A 1 HOM115PDFb 312.00 20 A 1 HOM120PDFb 312.00 HOM-GFI HOM-GFI circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 milliamperes or more. 2P—120/240 Vac Common Trip 1P—120 Vac Ampere Rating HOM 1P GFI (With Ground Fault Circuit Interrupter) 1 Space Required 15 A 20 A 30 A 40 A 50 A AIR 10 kA 10 kA 10 kA 10 kA 10 kA Table 1.41: 1 Space Required Cat. No. HOM115GFI HOM120GFI — — — 2 Spaces Required $ Price 212.00 212.00 — — — Cat. No. HOM215GFI HOM220GFI HOM230GFI HOM240GFI HOM250GFI $ Price 413.00 413.00 413.00 413.00 413.00 HOM-EPD—10 k AIR Homeline Equipment Protection Device—Circuit Breakers with 30 mA Equipment Ground Fault Protection (UL Listed) 2P—120/240 Vac 1P—120 Vac Common Trip Amperes Cat. No. HOM 2P GFI (With Ground Fault Circuit Interrupter) 2 Spaces Required 1-14 15 A 20 A 25 A 30 A 40 A 50 A HOM115EPD HOM120EPD — — — — $ Price 374.00 374.00 — — — — DE3D Cat. No. $ Price HOM215EPD HOM220EPD HOM225EPD HOM230EPD HOM240EPD HOM250EPD DE3C DE2E 660.00 660.00 660.00 660.00 660.00 660.00 Discount Schedule AIR 2P Tandem—120/240 Vac (Two Spaces Required) 2P Cat. No. $ Price (2) 15 A 15 A 10 kA HOMT1515215 b 120.00 HOMT1515220 b 120.00 (2) 15 A 20 A 10 kA HOMT1515225 b 120.00 (2) 15 A 25 A 10 kA HOMT1515230 b 120.00 (2) 15 A 30 A 10 kA HOMT1515240 b 120.00 (2) 15 A 40 A 10 kA HOMT1515250 b 120.00 (2) 15 A 50 A 10 kA HOMT2020220 b 120.00 (2) 20 A 20 A 10 kA (2) 20 A 25 A 10 kA HOMT2020225 b 120.00 HOMT2020230 b 120.00 (2) 20 A 30 A 10 kA HOMT2020240 b 120.00 (2) 20 A 40 A 10 kA HOMT2020250 b 120.00 (2) 20 A 50 A 10 kA Note: Typical catalog number (e.g. HOMT 1515230) represents two 1P, outer poles (two 15 A 1P CBs) and one 2P inner circuit breaker with common trip (one 30 A 2P CB). Table 1.44: Circuit Breaker Wire Sizesf Wire Size (AWG/kcmil) Breaker Type Ampere Rating Aluminum HOM 1P 15–30 A 14–8 AWG HOM 2P Two-Pole Combination Arc-Fault Circuit Interrupter with Pigtail Neutral 1P Tandem—120/240 Vac (One Space Required) Cat. No. $ Price 15 and 15 A 10 kA HOMT1515 b 52.00 15 and 20 A 10 kA HOMT1520 b 52.00 HOMT2020 b 52.00 20 and 20 A 10 kA HOMT3015 b 52.00 30 and 15 A 10 kA HOMT3020 b 52.00 30 and 20 A 10 kA a UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. b UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. c For 120/240 V only, not for 208Y/120 V. One-Pole Combination Arc-Fault Circuit Interrupter with Pigtail Neutral Plug-On Neutral Combination Arc-Fault Interrupter AIR HOMT and Quad Quad Only HOM-GFI - 1P HOM-GFI - 2P Table 1.45: 40–50 A 8–2 AWG 15–30 A 14–8 AWG 35–70 A 80–125 A 150–200 A 15–30 A 40–50 A 15–20 A 15–50 A 8–2 AWG 4–2/0 AWG 4 AWG–300 kcmil 14–8 AWG 6–12 AWG 14–10 AWG 12–4 AWG Copper 14–8 AWG or (2) 14–10 AWG 8–2 AWG 14–8 AWG or (2) 14–10 AWG 8–2 AWG 4–2/0 AWG 4 AWG–300 kcmil 14–8 AWG 6–14 AWG 14–10 AWG 14–6 AWG Accessories Description Cat. No. $ Price Handle Attachments Handle Tie: Converts any two adjacent 120/240 Vac HOM1HTh 3.50 single HOM circuit breakers to independent trip 2P Handle Tie: Converts any two adjacent 120/240 Vac HOMTHTh 3.80 1P side-by-side HOMT circuit breakers to independent trip 2P Handle Clamp: Clamp for holding HOM 1P handle in QO1LOi 3.80 the ON or OFF position Handle Blocking Device: Attaches to standard HOM 10.70 2P circuit breakers for holding the handle in the OFF HOM2HBDh position Handle Padlock Attachment: For padlocking 1P HOM1PAh 9.90 Standard HOM breakers in the ON or OFF position HOM2PALAh 9.90 15–70 A Handle Padlock Attachment: For 80–125 A HOM2PAHAh padlocking 2P Standard HOM circuit 9.90 breakers in ON or OFF position 150–200 A HOM2PAVHAh 50.00 Handle Padlock Attachment: For padlocking 1P CAFI, DF, GFI, and EPD HOM breakers in ON or OFF HOMELEC1PA 9.90 position Handle Padlock Attachment: For padlocking 2P CAFI, HOMELEC2PALA 9.90 GFI, and EPD HOM breakers in ON or OFF position Handle Padlock Attachment: For padlocking center HOMQPA 9.90 poles of Homeline Quad breakers in the OFF position Handle Padlock Attachment: For 11.00 50–125 A QOM1PAgi padlocking main circuit breakers in 11.00 convertible load center in OFF position 100–225 A QOM2PAgi Sub-Feed Lugs HOML2125 47.60 125 A 2P plug-on—2 spaces required 225 A 2P plug-on—4 spaces required HOML2225d 296.00 d Requires four spaces (1 AWG–300 kcmil Al/Cu). Use only in 1Ø panel rated 150 A or greater. e 15–20 A tandem or quad tandem circuit breakers are suitable for use with 60oC or 75oC conductors. 25–50 A tandem or quad tandem circuit breakers are suitable for use with 75oC conductors only. f 15–30 A circuit breakers are suitable for use with 60oC or 75oC conductors. 40–125 A circuit breakers are suitable for use with 75oC conductors. g 50–125 A QOM1 frame size; 100–225 A QOM2 frame size. h DE3C Discount Schedule i DE2E Discount Schedule © 2012 Schneider Electric All Rights Reserved Homeline™ Load Centers Indoor, 1Ø, Main Lugs and Main Circuit Breaker Class 1170 / Refer to Catalog 1100CT0501 www.schneider-electric.us 1Ø3W—120/240 Vac—UL Listed Spaces Max. Single Pole Circuits a Load Center Box, Interior and Cover b Max. Tandem Circuit Breakers Main Wire Size AWG/kcmil $ Price (DE3C) Cat. No. Al Cu Equipment Ground Bar Kit (Order Separately) Cat. No. $ Price Box No. See Page 1-17 Main Lugs—10 kA Short Circuit Current Rating Order HOM Circuit Breakers (See page 1-14) Factory-installed Fixed Main Lugs 70 A 100 A 125 A 2 6 4 4 12 8 2 6 4 HOM24L70F/Sdc HOM612L100F/Sce HOM48L125GC 59.00 78.00 86.00 12–3 14–4 8–1 PK3GTA1 PK7GTA PK7GTA Factory-included 11.40 11.70 2 4 21 12–2/0 14–2/0 132.00 174.00 260.00 237.00 360.00 6–2/0 6–1 6–1 6–1/0 6–1/0 6–2/0 PK9GTA PK15GTA PK15GTA PK18GTA PK23GTA 13.40 17.10 17.10 18.80 21.30 6 6 8 8 10 420.00 618.00 732.00 902.00 4–300 4–250 PK23GTA PK27GTA PK27GTA PK27GTA 21.30 33.80 33.80 33.80 10 12 12 25 150.00 204.00 288.00 344.00 6-2/0 6–1 6–1 6–1/0 6–1/0 PK15GTAL Included PK15GTAL Included PK15GTAL Included PK15GTAL Included 6 6 8 8 4–250 PK15GTAL & PK15GTA Included PK15GTAL Included PK15GTAL Included PK15GTAL & PK15GTA Included PK15GTAL & PK15GTA Included 10 9 9 12 12 Convertible Mains—Factory-installed Main Lugs QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-16) 125 A 8 12 16 20 30 16 24 32 40 60 8 12 16 20 30 HOM816L125PC HOM1224L125PC HOM1632L125PC HOM2040L125PC HOM3060L125PC Convertible Mains—Factory-installed Main Lugs QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-16) HOM3060L225PC 30 60 30 HOM4080L225PC 40 80 40 225 A 42 84 42 HOM4284L225PC HOM60120L225PC f 60 120 60 Convertible Mains—Factory-installed Main Lugs—Ground Bar Included QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-16) 125 A I N D O O R 8 12 20 24 16 24 40 48 8 12 20 24 HOM816L125PGC HOM1224L125PGC HOM2040L125PGC HOM2448L125PGC Convertible Mains—Factory-installed Main Lugs—Ground Bar Included QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-16) 225 A 30 16 20 40 42 60 32 40 80 84 30 16 20 40 42 HOM3060L225PGC HOM1632L225PGC HOM2040L225PGC HOM4080L225PGC HOM4284L225PGC 618.00 357.00 417.00 839.00 804.00 4–300 Main Circuit Breaker—22 kA Short Circuit Current Rating Convertible Mains—Factory-installed Main Circuit Breaker QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 1-16) 100 A 125 A 8 12 20 24 30 24 30 16 24 40 48 60 48 60 8 12 20 24 30 24 30 HOM816M100PC HOM1224M100PC HOM2040M100PC HOM2448M100PC HOM3060M100PC HOM2448M125PC HOM3060M125PC 315.00 384.00 396.00 513.00 672.00 710.00 812.00 6–1 6–2/0 6–1 6–2/0 6–2/0 6–2/0 6–3 6–1 6–3 6–1/0 6–2/0 6–1/0 6–2/0 PK9GTA PK15GTA PK18GTA PK23GTA PK23GTA PK23GTA PK23GTA 13.40 17.10 18.80 21.30 21.30 21.30 21.30 5 6 7 8 10 8 10 PK23GTA 21.30 10 PK18GTA PK23GTA PK27GTA PK27GTA PK27GTA PK27GTA 18.80 21.30 33.80 33.80 33.80 33.80 9 10 12 12 25 12 Convertible Mains—Factory-installed Main Circuit Breaker QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 1-16) 150 A 30 60 30 HOM3060M150PC 776.00 4–250 HOM2040M200PC 711.00 20 40 20 30 60 30 HOM3060M200PC 798.00 HOM4080M200PC 1019.00 4–250 40 80 40 200 A 42 84 42 HOM4284M200PC 1313.00 HOM60120M200C f 1876.00 60 120 60 225 A 42 84 42 HOM4284M225PC 1116.00 4–300 4–250 Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers. b C at end of catalog number indicates combination flush/surface cover included with device. c F/S at end of catalog number indicates to order F for flush device or S for surface device. The cover does not have a door. d HOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire. e 70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker. f Door kit available separately. Order QOCDK60 $237.00. © 2012 Schneider Electric All Rights Reserved DE3A DE3C Discount Schedule 1-15 LOAD CENTERS Mains Rating Convertible Main Load Centers (Accepts Only HOM Plug-On Circuit Breakers.) 1 Table 1.46: Homeline™ Load Centers Rainproof, 1Ø, Main Lugs and Main Circuit Breakers Class 1170 / Refer to Catalog 1100CT0501 www.schneider-electric.us 1 1Ø3W—120/240 Vac—UL Listed Table 1.47: Convertible Main Load Centers (Accepts Only HOM Plug-On Circuit Breakers.) Mains Rating Spaces Max. Single Pole Circuits a Max. Tandem Circuit Breakers Load Center Box, Interior and Cover Cat. No. (DE3C) Main Wire Size AWG/kcmil $ Price Al Cu Equipment Ground Bar Kit (Order Separately) Cat. No. (DE3A) $ Price Box No. See Page 1-18 Main Lugs—10 kA Short Circuit Current Rating LOAD CENTERS Factory-installed Fixed Main Lugs, 10 kA Short Circuit Current Rating 70 A 100 A 125 A 2 6 4 4 12 8 2 6 4 HOM24L70RBb HOM612L100RBf HOM48L125GRB 111.00 129.00 137.00 12–3 14–4 8–1 12–2/0 14–2/0 PK4GTA 10.80 PK7GTA 11.70 PK7GTA Factory-included 1R 2R 15R PK9GTA PK15GTA PK18GTA PK23GTA 13.40 17.10 18.80 21.30 3R 3R 4R 6R PK9GTA PK15GTA PK18GTA PK23GTA PK27GTA PK27GTA 13.40 17.10 18.80 21.30 33.80 33.80 5R 6R 6R 7R 14R 14R Convertible Mains with Factory-installed Main Lugs c, QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See Below) R A I N P R O O F 125 A 8 12 20 24 16 24 40 48 8 12 20 24 HOM816L125PRB HOM1224L125PRB HOM2040L125PRB HOM2448L125PRB 248.00 278.00 383.00 390.00 6–2/0 6–1 Convertible Mains with Factory-installed Main Lugs c, QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See Below) 225 A 12 16 20 30 40 42 12 32 40 60 80 84 0 16 20 30 40 42 HOM12L225PRB HOM1632L225PRB HOM2040L225PRB HOM3060L225PRB HOM4080L225PRB HOM4284L225PRB 423.00 510.00 560.00 759.00 1139.00 1092.00 4–300 4–250 Main Circuit Breaker—22 kA Short Circuit Current Rating R A I N P R O O F Convertible Mains with Factory-Installed Main Circuit Breaker, QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) d HOM816M100PRB 429.00 PK9GTA 13.40 3R 8 16 8 12 24 12 6–2/0 HOM1224M100PRB 416.00 PK15GTA 17.10 3R 100 A 6–1 20 40 20 HOM2040M100PRB 531.00 PK18GTA 18.80 4R HOM816M125PRB 716.00 PK9GTA 13.40 3R 8 16 8 6–2/0 125 A 6–1 HOM2448M125PRB 858.00 PK23GTA 21.30 6R 24 48 24 Convertible Mains with Factory-installed Main Circuit Breaker, QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) 150 A 30 60 30 HOM3060M150PRB 978.00 4–250 PK23GTA 21.30 7R HOM12M200PRB 795.00 PK9GTA 13.40 5R 12 12 0 20 40 20 HOM2040M200PRB 872.00 PK18GTA 18.80 6R 4–250 200 A HOM3060M200PRB 1152.00 PK23GTA 21.30 7R 30 60 30 HOM4080M200PRB 1596.00 PK27GTA 33.80 14R 40 80 40 Convertible Mains with Factory-installed Main Circuit Breaker with Feed-thru Lugs, QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) c 150 A 8 16 8 HOM816M150PFTRB 785.00 4–250 PK15GTA 35.00 6R 200 A 8 16 8 HOM816M200PFTRB 785.00 4–250 PK15GTA 35.00 6R Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers. b HOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire. c Side hinge door device allow 1-1/4 in. on left side for door to open. d 22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. e Rated 200 A when using copper wire. Reference NEC® Table 310.15(B)(6) when using Al wire. f 70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker. 1Ø, Field-Installed Mains Kits Table 1.48: Main Lug Kit QOL125 QOL225 1-16 Field-Installed Main Type For Convertible Load Centers Only Main g Use on Convertible Load $ Price Lug Wire Size j Cat. No. Ampere Rating Center with Mains Rating (DE3A) AWG/kcmil 125 A 100–125 A QOL125 44.10 6–2/0 Al or Cu Main Lugs h — 225 A 150–225 A QOL225 104.00 6–300 Al or Cu QOM50VH 140.00 50 A 100–125 A 60 A 100–125 A QOM60VH 140.00 QOM70VH 140.00 70 A 100–125 A QOM80VH 201.00 80 A 100–125 A 12–2/0 Al or Cu QOM1 90 A 100–125 A QOM90VH 201.00 QOM100VH 201.00 100 A 100–125 A 110 A 125 A QOM110VH 468.00 Main Circuit Breaker i QOM125VH 468.00 125 A 125 A 100 A 150–225 A QOM2100VH 468.00 QOM2125VH 468.00 125 A 150–225 A 150 A 150–225 A QOM2150VH 468.00 QOM2k 4–300 Al or Cu QOM2175VH 468.00 175 A 200–225 A 200 A 200–225 A QOM2200VH 468.00 QOM2225VH 468.00 225 A 225 A g Do not exceed the load center mains rating. h If main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from page 1-13. i 22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. j Wire range listed for main device kits is the wire range of that device. To find out maximum wire size permitted in a particular load center per UL, see pages 1-5 through 1-11 under Main Wire Size. k Add suffix 1021 for 120, 208, 240 Vac shunt trip. Frame Size DE3A DE3C Discount Schedule © 2012 Schneider Electric All Rights Reserved QO™ and Homeline™ Load Centers Indoor, Dimensions and Knockouts Class 1130, 1170 / Refer to Catalog 1100CT0501 ZZZVFKQHLGHUHOHFWULFXV Indoor Knockout Information and Enclosure Dimensions A A,B,C,D A,B,C A,B,C A Table 1.49: A,B,C A Enclosure Dimensions A,B,C A,B Box 3 Box 1 A A,B B,C,D,E B,C,D,E C,D,E,F,G A A,B B,C,D,E C,D,E,F B,C,D,E B,C,D,E A A,B A A B,C,D,E B,C,D,E Dimensions H D in. mm in. mm in. mm 1 2 3 4 5 6 7 8 9 10 11 12 13 3.81 4.81 4.81 8.88 14.25 14.25 14.25 14.25 14.25 14.25 14.25 14.25 5.88 97 122 122 226 362 362 362 362 362 362 362 362 149 6.72 9.30 9.30 12.57 14.92 17.92 20.92 26.04 29.86 33.78 37.98 39.37 13.12 171 236 236 319 379 455 531 661 758 858 965 1000 333 3.00 3.19 3.19 3.80 3.75 3.75 3.75 3.75 3.75 3.75 3.75 3.75 3.38 76 81 81 97 95 95 95 95 95 95 95 95 86 W H D Box No. in. mm in. mm in. mm 14 15 16 17 18 19 20 21 22 23 24 25 14.25 20.00 20.00 20.00 5.88 7.56 9.62 8.88 8.55 14.25 14.25 14.25 362 508 508 508 149 192 244 226 217 362 362 362 20.92 50.00 62.00 53.00 16.12 23.12 26.12 14.80 23.92 29.86 43.15 48.50 531 1270 1727 1346 409 587 663 376 608 758 1096 1235 3.75 5.75 5.75 5.75 3.38 4.25 4.75 3.80 3.95 3.75 3.75 3.75 95 146 146 146 86 108 121 97 100 95 95 95 A,B,C,D B,C,D,E Box 4 Table 1.50: Box 5 Knockout Information Knockouts B,C,D,E B,C,D,E C,D,E,F,G C,D,E,F,G A B C Conduit Size 1/2 3/4 1 B,C,D,E C,D,E,F,G D E 1-1/4 1-1/2 F G H I 2 2-1/2 3 3-1/2 C,D,E,F,G B,C,D,E C,D,E,F A A,B A A,B D,E,F,G B,C,D,E C,D,E,F A A,B Symbol B,C,D,E C,D,E,F A A,B B,C,D,E D,E,F,G C,D,E,F B,C C,D,E,F,G D,E,F,G A A,B B,C,D,E D,E,F,G B,C A,B B,C,D,E C,D,E,F A,B A,B A A,B A A A A,B,C,D A,B,C,D B,C,D,E A,B,C,D C,D,E,F D,E,F,G A,B,C,D Box 9 Box 7 B,C,D,E C,D,E,F C,D,E,F,G D,E,F,G A A,B B,C,D,E D,E,F,G B,C,D,E B,C,D,E C,D,E,F,G D,E,F,G B,C A,B,C,D C,D,E,F D,E,F,G Box 10 A A,B C,D,E,F D,E,F,G A,B D,E,F,G,H D,E,F,G,H,I C,D,E,F B,C A A,B A,B,C D,E,F,G A,B B,C,D,E A,B C,D,E,F C,D,E,F A,B,C,D A A,B A A A,B,C,D C,D,E,F D,E,F,G A,B,C,D B,C,D,E A,B,C,D B,C,D,E C,D,E,F Box 14 Box 13 Box 11 A C,D,E,F D,E,F,G C,D,E,F D,E,F,G A,B B,C,D,E D,E,F,G B,C C,D,E,F E,F,G,H A,B,C,D A,B,C D,E,F,G A,B D,E,F,G A B,C,D,E A,B B,C,D,E B,C,D,E A A A,B B,C,D,E B,C,D,E C,D,E,F B,C,D,E D,E,F,G A,B,C,D C,D,E,F Box 19 © 2012 Schneider Electric All Rights Reserved 1-17 LOAD CENTERS A W Box No. 1 Dimensions A QO™ Load Centers Indoor, 1Ø, Main Lugs and Main Breaker Class 736, 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us QO Plug-on Neutral Load Centers and CAFI Breakers connect are engineered for a quick Plug-on Neutral connection on every unit. $ Price Load Center Box and Interior Max. Max. 1P Tandem (Interior, Spaces Box & Circuits Breakers Cover) Cat. No. $ Price Equipment Main Wire Ground Bar Kit Box No. Size (Order Separately See AWG/kcmil If Priced) Page 1-17 $ Price Al/Cu Cat. No. $ Price Indoor Cover with Door (Order Separately) Flush Cat. No. Surface Cat No. Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating — Copper Bus QOM1 Main Frame Size, Convertible to Main Circuit Breaker 125 A 24 24 572.00 0 534.00 QOC24UF QOC24US QO124L125PG 37.70 6–2/0 PK15GTA Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating — Copper Bus QOM2 Main Frame Size, Convertible to Main Circuit Breaker 597.00 QOC30UF QOC30US 87.00 6–250 PK23GTA, LK100AN 200 A 30 30 0 684.00 QO130L200PG 907.00 QOC42UF QOC42US 111.00 (2) PK15GTA 42 42 0 1018.00 QO142L225PG 6–300 225 A 54 54 0 1356.00 QO154L225PG 1177.00 QOC54UF — 179.00 PK23GTA, LK100AN Convertible Mains — Factory-Installed Main Circuit Breaker — 22 kA Short Circuit Current Rating — Copper Bus QOM1 Main Circuit Breaker Frame Size, Convertible to Main Lugs or Lower Amperage Main Circuit Breaker I N D O O R 100 A QO154M200P 24 24 828.70 0 791.00 QOC24UF QOC24US QO124M100P 37.70 6–2/0 Convertible Mains — Factory-Installed Main Circuit Breaker — 22 kA Short Circuit Current Rating — Copper Bus QOM2 Main Circuit Breaker Frame Size, Convertible to Main Lugs or Lower Amperage Main Circuit Breaker QO130M200P 1043.00 QOC30UF QOC30US 87.00 30 30 0 1130.00 QO142M200P 1249.00 QOC42UF QOC42US 111.00 42 42 0 1360.00 4–250 200 A 54 54 0 1618.00 QO154M200P 1439.00 QOC54UF — 179.00 — 267.00 60 60 0 1916.00 QO160M200PCac 1916.00 QOC60UFa Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating — Cu Bus QOM1 Main Circuit Breaker Frame Size, Convertible to Main Circuit Breaker — Equipment Ground Bar Included — — — 6–2/0 125 A 24 24 0 712.00 QO124L125PGRB 712.00 Table 1.74: 7 9 11 12 PK15GTA 17.10 7 PK18GTA PK23GTA PK23GTA PK23GTA 18.80 21.30 21.30 21.30 9 11 12 24 PK15GTA Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating — Cu Bus QOM2 Main Circuit Breaker Frame Size, Convertible to Main Circuit Breaker — Equipment Ground Bar Included 30 30 0 856.00 QO130L200PGRB 856.00 — — — 6–250 PK23GTA, LK100AN O 200 A U 225 A 42 42 0 1500.00 QO142L225PGRB 1500.00 — — — 6–300 (2) PK15GTA T D Convertible Mains — Factory-Installed Main Circuit Breaer — 22 kA Short Circuit Current Rating — Copper Bus O Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5), O QOM1 Main Circuit Breaker Frame Size R 100 A — — — 6–2/0 PK15GTA 17.10 24 24 0 1144.00 QO124M100PRB 1144.00 b Convertible Mains — Factory-Installed Main Circuit Breaer — 22 kA Short Circuit Current Rating — Copper Bus Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5), QOM2 Main Circuit Breaker Frame Size 150 A 30 30 0 1344.00 QO130M150PRB 1344.00 — — — PK18GTA 18.80 30 30 0 1344.00 QO130M200PRB 1344.00 4–250 — — — PK18GTA 21.30 200 A — — — PK23GTA 21.30 42 42 0 1659.00 QO142M200PRB 1659.00 a Door kit available separately Order QOCDK60 $237.00. b All OUTDOOR devices are available FACTORY ORDER only. c Cover comes included with load center. 4R 6R 8R 4R 6R 6R 8R QO Arc Fault Circuit Breakers 1P 120 Vac 1P 120 Vac 10 k AIR 22 k AIR 1 Space Required 1 Space Required Circuit Breaker Type Ampere Rating Cat. No. $ Price Cat. No. $ Price Combination Arc-fault Interrupter (Pigtail Neutral) Plug-On Neutral Combination Arc-fault Interrupter 15 QO115CAFI 282.00 QO115VHCAFI 534.00 20 QO120CAFI 282.00 QO120VHCAFI 534.00 15 QO115PCAFI 282.00 QO115VHPCAFI 534.00 20 QO120PCAFI 282.00 QO120VHPCAFI 534.00 QO-Dual Function Circuit Breaker QO Combination Arc Fault and Ground Fault Circuit Interrupters (Dual Function) provide overload and short circuit protection, plus arc fault and ground fault protection in accordance with the NEC, UL1699 and UL943. Table 1.75: 1P QO-DF QO-Dual Function Arc Fault Circuit Breakersa 1P 120 Vac Circuit Breaker Type Combination Arc-fault and Ground Fault Circuit Interrupter (Pigtail Neutral) Plug-On Neutral Combination Arc-fault and Ground Fault Circuit Interrupter Ampere Rating 15 1P 120 Vac 10 k AIR 22 k AIR 1 Space Required 1 Space Required Cat. No. QO115DF $ Price 326.00 Cat. No. QO115VHDF $ Price 578.00 20 QO120DF 326.00 QO120VHDF 578.00 15 QO115PDF 326.00 QO115VHPDF 578.00 20 QO120PDF 326.00 QO120VHPDF 578.00 Schneider Electric 1601 Mercer Road Lexington, KY 40511 USA (1-888-778-2733) www.schneider-electric.us Document No. 0100CT1401 July 2014 © 2012 Schneider Electric All Rights Reserved DE2A DE3A Discount Schedule LOAD CENTERS Mains Rating QO Plug-on Neutral CAFI Load Center (accepts QO Circuit Breakers only) 1-27 1 Table 1.73: