ECOTHERM Heat Transfer Technology www.ecotherm.com Model EHRE heating water 100 - 600 kW High Capacity Water Heater EH ® ECOTHERM Model EHRE, 100 - 600 kW ® Heat Transfer Technology Model EHRE: High capacity water heater 100 - 600 kW Stainless steel AISI-316Ti for lifelong service Freshly made, hygienic hot water Legionella decontamination cycle, 'Anti-Legio' design Anti-fouling cycle Microprocessor control with optional remote control via PC Description High capacity water heater for water/water operation. External heat exchanger with free floating turbulator rods for increased efficiency and self cleaning effect. Insulated hot water storage tank, upright standing. All parts in contact with water are made entirely of stainless steel AISI-316Ti. 'Anti-Legio' design fully compliant with European anti-legionella recommendations. Primary & secondary circulating pumps, motorised control valve on primary circuit, 4 temperature sensors for preheat start-up, heating cycle start, heating cycle stop and antifouling cooling cycle. Microprocessor control unit with volt free output signals for boiler request and alarm. Input signal for remote operation. All components are pre-assembled and wired. Simple on-site assembly. Output performance Output rating: 100 - 600 kW Storage capacity: 540, 1000, 2000 litres, or larger Peak hot water output: 3030 - 18440 litres/hr at 45°C (Higher output and storage capacities available on request) Pressure ratings Tank <= 1000 litres Safety valve setting 10 bar Testing pressure 13 bar Tank > 1000 litres 6 bar* 10 bar* *) Higher pressures available on request Microprocessor control unit User friendly menus for customised installation. Exact control of programmed hot water temperature. Anti-fouling cycle and permanent monitoring of secondary circuit differential pressure loss with fouling alarm, uploadable to BMS. Legionella decontamination cycle. Continuous status monitoring and memory storage of output values. Storage tank insulation CFC-free hard polyurethane foam (fire protection class B2 DIN 4102) Grey aluminium casing, removable. 70mm thickness for tank sizes below 800 litres 90mm thickness for tank sizes from 800 litres Accessories optional Violet aluminium front cover External cooling for anti-fouling Heat exchanger sludge flushing kits T5 strap-on temperature sensor for district heating Remote control and monitor via PC or BMS using TCP/IP network, internet or telephone. Differential pressure sensor ensures operational safety by permenantly monitoring for possible heat exchanger fouling. Fitted as standard. High capacity Water Heaters models EH.. ECOTHERM ® Model EHRE, 100 - 600 kW Heat Transfer Technology Typ EHRE Funktionsschema Heating circle conduit - return to boiler Heating circle conduit - heating water from boiler HW Vorl HW Rückl. - Heating water from Boiler -Heating water return to boiler FS 11 9 9 7 9 Air vent Pp WT Rückl. - Heat exchanger return T3 9 17 WW - Hot water T5 M Datum 14.01.04 09:56 Anlage Ein Anlage Normal T1 Sp.oben 64.5 4 SV 8 on/off High Ca pacity Water H eaters & Boiler s ECOTHERM Heat Transfer Technology ® ELC-10.0 6 18 T4 11 9 10 14 9 Z - Circulation Z 11 9 9 12 2 16 15 KW - Cold water 5 Ps T1 T2 T2 17 14 1 6 8 9 MS MS 10 P1 3 17 P p P s P z V+ VB A A N S S 1 S S S S S 6 S S 8 V 1 V V Heating on 19 P2 Heating off 6 WT Vorl. - Heat exchanger feed 13 Drain Scope of delivery Type EHRE heating water Heat exchanger piping connections to the boiler circuit (primary), and to the domestic hot water circuit (secondary) 1*.... 2*.... 3*.... 4*.... 5*.... 6*.... 7*.... 8*.... 9 .... 10... 11 ... 12 ... 13 ... 14 ... 15 ... 16 ... 17 ... 18*... 19*... T1*... T2*... T3*... T4*... T5 ... SV*... Warm water tank Flange øi 190 mm Heat exchanger Primary pump (Pp) Domestic water pump (Ps) Shut-off-valves Modulating control valve Microprocessor control unit Shut-off-valves Circulating pump Fine filter Test valve Pressure reducer Non-return-valve Pressure gauge connection Safety valve Galvanic isolation union Non-return-valve Differential pressure sensor, Huba 692 Temperature sensor Charge “ON” Temperature sensor Charge “OFF” Temp. sensor, warm water charging temperature Temp. sensor, primay circuit delivery Temp. sensor, primay circuit return (option) Pressure relief valve * = Included in the scope of delivery WW... Hot water connection KW.... Cold water connection gem. per DIN 1988 part 2 and DIN 4753 part 1 Z... Circulation WTVorl... Cold water - feed from boiler WTRück... Warm water - output from boiler HWVorl... Hot water feed from boiler HWRückl... Hot water return to boiler High capacity Water Heaters models EH.. ECOTHERM Model EHRE, 100 - 600 kW ® Heat Transfer Technology Performance Data Type EHRE Tank capacity 300 litres, boiler water 75°55°C, domestic water 12°60°C (or 45°C after mixing with cold water) Model Nominal rating Continous hot water output 75°C55°C 12°C60°C 12°C45°C Type - kW - t1 - t2 - Vol kW EHRE-100-7555-1260-300 EHRE-120-7555-1260-300 EHRE-140-7555-1260-300 EHRE-160-7555-1260-300 EHRE-180-7555-1260-300 EHRE-200-7555-1260-300 EHRE-220-7555-1260-300 EHRE-225-7555-1260-300 EHRE-240-7555-1260-300 EHRE-250-7555-1260-300 EHRE-260-7555-1260-300 EHRE-275-7555-1260-300 EHRE-280-7555-1260-300 EHRE-300-7555-1260-300 100 120 140 160 180 200 220 225 240 250 260 275 280 300 Litres per hour 1800 2160 2520 2880 3240 3590 3950 4040 4310 4490 4670 4940 5030 5390 Litres per hour 2620 3140 3660 4180 4700 5230 5750 5880 6270 6530 6790 7180 7310 7840 Peak hot water output*** Peak hot water output*** Norm output* 12°C60°C 12°C45°C DIN 4708 Liter in 10 Min. 590 650 710 770 830 890 950 950 1010 1030 1070 1100 1130 1180 Liter in 1 Stunde 2080 2440 2800 3160 3520 3880 4240 4320 4590 4770 4950 5220 5310 5670 Liter in 10 Min. 850 940 1030 1120 1190 1280 1370 1390 1460 1500 1540 1610 1630 1720 Liter in 1 Stunde 3030 3550 4070 4600 5120 5640 6160 6290 6690 6940 7210 7590 7730 8250 Living Hotel units** units** 20 24 28 34 39 43 54 5 55 6 57 8 60 9 63 10 67 11 69 12 74 15 Tank capacity 540 litres, boiler water 75°55°C, domestic water 12°60°C (or 45°C after mixing with cold water) Model Nominal rating 75°C55°C 12°C60°C 12°C45°C Type - kW - t1 - t2 - Vol kW EHRE-100-7555-1260-540 EHRE-120-7555-1260-540 EHRE-140-7555-1260-540 EHRE-160-7555-1260-540 EHRE-180-7555-1260-540 EHRE-200-7555-1260-540 EHRE-220-7555-1260-540 EHRE-225-7555-1260-540 EHRE-240-7555-1260-540 EHRE-250-7555-1260-540 EHRE-260-7555-1260-540 EHRE-275-7555-1260-540 EHRE-280-7555-1260-540 EHRE-300-7555-1260-540 100 120 140 160 180 200 220 225 240 250 260 275 280 300 Continous hot water output Litres per hour 1800 2160 2520 2880 3240 3590 3950 4040 4310 4490 4670 4940 5030 5390 Litres per hour 2620 3140 3660 4180 4700 5230 5750 5880 6270 6530 6790 7180 7310 7840 Peak hot water output*** Peak hot water output*** Norm output* 12°C60°C 12°C45°C DIN 4708 Liter in 10 Min. 820 880 940 1000 1060 1120 1180 1200 1240 1270 1300 1350 1360 1420 Liter in 1 Stunde 2310 2670 3030 3390 3750 4110 4470 4560 4830 5010 5180 5460 5540 5900 Liter in 10 Min. 1190 1270 1360 1450 1530 1620 1710 1730 1800 1840 1880 1950 1970 2060 Liter in 1 Stunde 3360 3880 4410 4930 5450 5970 6490 6630 7020 7280 7540 7930 8060 8580 Living Hotel units** units** 33 40 47 55 61 63 74 10 75 12 77 15 80 18 83 20 87 23 89 25 94 30 High capacity Water Heaters models EH.. ECOTHERM ® Model EHRE, 100 - 600 kW Heat Transfer Technology Tank capacity 750 litres, boiler water 75°55°C, domestic water 12°60°C (or 45°C after mixing with cold water) Nominal rating Model Continous hot water output 75°C55°C 12°C60°C 12°C45°C Type - kW - t1 - t2 - Vol kW EHRE-100-7555-1260-750 EHRE-120-7555-1260-750 EHRE-140-7555-1260-750 EHRE-160-7555-1260-750 EHRE-180-7555-1260-750 EHRE-200-7555-1260-750 EHRE-220-7555-1260-750 EHRE-225-7555-1260-750 EHRE-240-7555-1260-750 EHRE-250-7555-1260-750 EHRE-260-7555-1260-750 EHRE-275-7555-1260-750 EHRE-280-7555-1260-750 EHRE-300-7555-1260-750 EHRE-325-7555-1260-750 EHRE-350-7555-1260-750 EHRE-375-7555-1260-750 EHRE-400-7555-1260-750 EHRE-425-7555-1260-750 EHRE-450-7555-1260-750 EHRE-475-7555-1260-750 EHRE-500-7555-1260-750 EHRE-550-7555-1260-750 EHRE-600-7555-1260-750 100 120 140 160 180 200 220 225 240 250 260 275 280 300 325 350 375 400 425 450 475 500 550 600 Litres per hour 1800 2160 2520 2880 3240 3590 3950 4040 4310 4490 4670 4940 5030 5390 5840 6290 6740 7180 7630 8080 8530 8980 9870 10770 Litres per hour 2620 3140 3660 4180 4700 5230 5750 5880 6270 6530 6790 7180 7310 7840 8490 9140 9790 10450 11100 11750 12400 13060 14360 15670 Peak hot water output*** Peak hot water output*** Norm output* 12°C60°C 12°C45°C DIN 4708 Liter in 10 Min. 1020 1080 1140 1200 1260 1320 1380 1400 1440 1470 1500 1550 1560 1610 1690 1760 1840 1910 1990 2060 2140 2210 2370 2520 Liter in 1 Stunde 2510 2870 3230 3590 3950 4310 4670 4760 5020 5210 5380 5660 5740 6100 6550 7000 7450 7900 8340 8790 9240 9690 10590 11490 Liter in 10 Min. 1480 1560 1650 1740 1820 1910 2000 2020 2090 2130 2170 2240 2260 2350 2460 2560 2670 2780 2890 3000 2110 3220 3440 3650 Liter in 1 Stunde 3650 4170 4700 5220 5740 6260 6780 6920 7310 7570 7830 8220 8350 8870 9530 10180 10830 11480 12140 12790 13440 14090 15400 16710 Living Hotel units** units** 41 10 48 15 55 20 63 25 70 30 74 35 78 40 79 41 82 45 85 47 88 50 92 53 94 55 112 60 133 65 142 70 152 75 161 80 171 85 180 90 190 95 200 100 220 110 240 120 .....continous next page Key to model number Opt _Type _ _ _ – _ kW _ _ _ – _ _t1_ _ – _ _t2_ _ – _ Vol ___–_ _ 8 } 7 } 6 } 5 } 1 2 3 4 9 10 Type 1stdigit: E = ECOTHERM high capacity water heater 2nddigit: H = Heating water type boiler 3rddigit: R = Shell and tube heat exchanger 4thdigit: E = Electronic control kW 5thdigit: Heat exchanger performance rating in Kilowatt t1 6thdigit: Feed temperature from boiler in °C 7thdigit: Return temperature to boiler in °C High capacity Water Heaters models EH.. 11 t2 8thdigit: Domestic cold water inlet temperaure in °C 9thdigit: Domestic hot water output temperature in °C Vol 10th digit: Tank capacity in Litres Opt - Options 11th digit: F = Violet front cover, D = Double tank, N = Network remote control, M = Modem remote control, A = Electric anode, T5 = Sensor for district heating, E = External antifouling cooling, S = Heat exchanger sludge flushing kit ECOTHERM Model EHRE, 100 - 600 kW ® Heat Transfer Technology Performance Data ...continous Tank capacity 1000 litres, boiler water 75°55°C, domestic water 12°60°C (or 45°C after mixing with cold water) Model Nominal rating Continous hot water output 75°C55°C 12°C60°C 12°C45°C Type - kW - t1 - t2 - Vol kW EHRE-100-7555-1260-1000 EHRE-120-7555-1260-1000 EHRE-140-7555-1260-1000 EHRE-160-7555-1260-1000 EHRE-180-7555-1260-1000 EHRE-200-7555-1260-1000 EHRE-220-7555-1260-1000 EHRE-225-7555-1260-1000 EHRE-240-7555-1260-1000 EHRE-250-7555-1260-1000 EHRE-260-7555-1260-1000 EHRE-275-7555-1260-1000 EHRE-280-7555-1260-1000 EHRE-300-7555-1260-1000 EHRE-325-7555-1260-1000 EHRE-350-7555-1260-1000 EHRE-375-7555-1260-1000 EHRE-400-7555-1260-1000 EHRE-425-7555-1260-1000 EHRE-450-7555-1260-1000 EHRE-475-7555-1260-1000 EHRE-500-7555-1260-1000 EHRE-550-7555-1260-1000 EHRE-600-7555-1260-1000 100 120 140 160 180 200 220 225 240 250 260 275 280 300 325 350 375 400 425 450 475 500 550 600 Litres per hour 1800 2160 2520 2880 3240 3590 3950 4040 4310 4490 4670 4940 5030 5390 5840 6290 6740 7180 7630 8080 8530 8980 9870 10770 Litres per hour 2620 3140 3660 4180 4700 5230 5750 5880 6270 6530 6790 7180 7310 7840 8490 9140 9790 10450 11100 11750 12400 13060 14360 15670 Peak hot water output*** Peak hot water output*** Norm output* 12°C60°C 12°C45°C DIN 4708 Liter in 10 Min. 1250 1310 1370 1430 1490 1550 1610 1630 1670 1700 1730 1780 1790 1850 1930 2000 2080 2150 2230 2300 2380 2450 2595 2745 Liter in 1 Stunde 2750 3110 3470 3830 4190 4540 4900 4990 5260 5440 5620 5890 5980 6340 6790 7240 7690 8130 8580 9030 9480 9930 10820 11720 Liter in 10 Min. 1820 1910 2000 2080 2170 2260 2340 2360 2430 2470 2520 2580 2610 2690 2800 2910 3020 3130 3240 3340 3450 3560 3780 4000 Liter in 1 Stunde 4000 4520 5040 5560 6090 6610 7130 7260 7650 7910 8170 8560 8700 9220 9870 10520 11180 11830 12480 13130 13790 14440 15740 17047 Living Hotel units** units** 53 15 57 20 61 25 71 30 74 35 78 40 83 45 85 47 88 50 91 53 94 55 108 58 112 60 133 65 148 70 156 75 173 80 182 85 190 90 197 95 207 100 224 105 254 110 285 115 Tank capacity 1500 litres, boiler water 75°55°C, domestic water 12°60°C (or 45°C after mixing with cold water) Model Nominal rating 75°C55°C 12°C60°C 12°C45°C Type - kW - t1 - t2 - Vol kW EHRE-100-7555-1260-1500 EHRE-120-7555-1260-1500 EHRE-140-7555-1260-1500 EHRE-160-7555-1260-1500 EHRE-180-7555-1260-1500 EHRE-200-7555-1260-1500 EHRE-220-7555-1260-1500 EHRE-225-7555-1260-1500 EHRE-240-7555-1260-1500 EHRE-250-7555-1260-1500 EHRE-260-7555-1260-1500 EHRE-275-7555-1260-1500 EHRE-280-7555-1260-1500 EHRE-300-7555-1260-1500 EHRE-325-7555-1260-1500 EHRE-350-7555-1260-1500 EHRE-375-7555-1260-1500 EHRE-400-7555-1260-1500 EHRE-425-7555-1260-1500 EHRE-450-7555-1260-1500 EHRE-475-7555-1260-1500 EHRE-500-7555-1260-1500 EHRE-550-7555-1260-1500 EHRE-600-7555-1260-1500 100 120 140 160 180 200 220 225 240 250 260 275 280 300 325 350 375 400 425 450 475 500 550 600 Continous hot water output Litres per hour 1800 2160 2520 2880 3240 3590 3950 4040 4310 4490 4670 4940 5030 5390 5840 6290 6740 7180 7630 8080 8530 8980 9870 10770 Litres per hour 2620 3140 3660 4180 4700 5230 5750 5880 6270 6530 6790 7180 7310 7840 8490 9140 9790 10450 11100 11750 12400 13060 14360 15670 Peak hot water output*** Peak hot water output*** Norm output* 12°C60°C 12°C45°C DIN 4708 Liter in 10 Min. 1730 1790 1850 1910 1970 2030 2090 2110 2150 2180 2210 2260 2270 2330 2400 2480 2550 2630 2700 2780 2850 2930 3080 3230 Liter in 1 Stunde 3220 3580 3940 4300 4660 5020 5380 5470 5740 5920 6100 6370 6460 6810 7260 7710 8160 8610 9060 9510 9950 10400 11300 12200 Liter in 10 Min. 2510 2600 2690 2770 2860 2950 3030 3050 3120 3160 3210 3270 3300 3380 3490 3600 3710 3820 3930 4040 4140 4250 4470 4690 Liter in 1 Stunde 4690 5210 5730 6250 6780 7300 7820 7950 8340 8600 8860 9250 9390 9910 10560 11210 11870 12520 13170 13820 14480 15130 16430 17740 Living Hotel units** units** 61 22 64 30 67 38 78 43 83 50 89 58 97 63 102 65 114 68 118 70 122 73 127 76 131 78 148 83 167 85 173 88 186 90 196 93 209 95 225 100 242 105 273 110 301 120 332 130 High capacity Water Heaters models EH.. ECOTHERM ® Model EHRE, 100 - 600 kW Heat Transfer Technology Tank capacity 2000 litres, boiler water 75°55°C, domestic water 12°60°C (or 45°C after mixing with cold water) Model Nominal rating Continous hot water output 75°C55°C 12°C60°C 12°C45°C Type - kW - t1 - t2 - Vol kW EHRE-100-7555-1260-2000 EHRE-120-7555-1260-2000 EHRE-140-7555-1260-2000 EHRE-160-7555-1260-2000 EHRE-180-7555-1260-2000 EHRE-200-7555-1260-2000 EHRE-220-7555-1260-2000 EHRE-225-7555-1260-2000 EHRE-240-7555-1260-2000 EHRE-250-7555-1260-2000 EHRE-260-7555-1260-2000 EHRE-275-7555-1260-2000 EHRE-280-7555-1260-2000 EHRE-300-7555-1260-2000 EHRE-325-7555-1260-2000 EHRE-350-7555-1260-2000 EHRE-375-7555-1260-2000 EHRE-400-7555-1260-2000 EHRE-425-7555-1260-2000 EHRE-450-7555-1260-2000 EHRE-475-7555-1260-2000 EHRE-500-7555-1260-2000 EHRE-550-7555-1260-2000 EHRE-600-7555-1260-2000 100 120 140 160 180 200 220 225 240 250 260 275 280 300 325 350 375 400 425 450 475 500 550 600 Litres per hour 1800 2160 2520 2880 3240 3590 3950 4040 4310 4490 4670 4940 5030 5390 5840 6290 6740 7180 7630 8080 8530 8980 9870 10770 Litres per hour 2620 3140 3660 4180 4700 5230 5750 5880 6270 6530 6790 7180 7310 7840 8490 9140 9790 10450 11100 11750 12400 13060 14360 15670 Peak hot water output*** Peak hot water output*** Norm output* 12°C60°C 12°C45°C DIN 4708 Liter in 10 Min. 2200 2260 2320 2380 2440 2500 2560 2580 2620 2650 2680 2730 2740 2800 2880 2950 3030 3100 3180 3250 3330 3400 3550 3700 Liter in 1 Stunde 3700 4060 4420 4780 5140 5490 5850 5940 6210 6390 6570 5130 6930 7290 7740 8190 8640 9080 9530 9980 10430 10880 11770 12670 Liter in 10 Min. 3200 3290 3380 3460 3550 3640 3730 3750 3810 3860 3900 3970 3990 4070 4180 4290 4400 4510 4620 4730 4840 4940 5170 5380 Liter in 1 Stunde 5380 5900 6420 6950 7470 7990 8510 8650 9030 9300 9560 9950 10080 10600 11250 11910 12560 13210 13860 14520 15170 15820 17130 18440 Living Hotel units** units** 66 26 70 35 74 44 85 49 92 58 100 66 111 71 117 73 125 76 131 79 136 81 145 84 151 86 163 91 186 93 190 94 198 95 211 96 228 98 254 103 277 108 322 113 360 123 410 133 Heating water temperature 75°55°C, Domestic water temperature boiler 12°C60°C. To produce hygienic hot water at 45°C ECOTHERM recommends running the ECOTHERM High Capacity Water Heater at 60°C for optimum safety against legionella infection, and then using a mixing unit (available from ECOTHERM on request) to mix down to 45°C for hot water distribution. *) Nominal output according to DIN 4708, T1 and T3. **) Living units: Nominal output type NL1 for living quarters, Hotel units: Nominal output type NL2 for hotels, hospitals and restaurants ***)Peak hot water output = Continuous hot water output + approx. 95% of tank capacity at 60°C For more information visit our homepage: www.ecotherm.com. High capacity Water Heaters models EH.. 20070426 EH_Fly Ecotherm English Distribution & Service: © Copyright Ecotherm Austria GmbH, all rights reserved. Subject to change without notice. High Capacity Water Heaters & Boilers ECOTHERM ® Heat Transfer Technology www.ecotherm.com ECOTHERM Austria GmbH,Karlinger Str. 8, A-4081 Hartkirchen, Europe email:office@ecotherm.at Tel.:+43-7273-6030 Fax:+43-7273-6030-15