Brochure

advertisement
PR14
V E R S A M AT E ® S E R I E S • P L U G S A N D R E C E P TA C L E S
V S I N O N - M E TA L L I C P L U G S A N D S W I T C H E D R E C E P TA C L E S
Class I, Div. 2, Groups A,B,C,D
Class I, Zones 1 & 2, Groups llC, llB, llA
AEx de IIC T6
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 3, 4, 4X, IP66
FM
File 3014299
APPROVED
Certified - File LR240743
See files for details or call Killark
F E AT U R E S - S P E C I F I C AT I O N S
Applications
• For use in hazardous and corrosive
environments such as refineries,
chemical plants, water treatment and
bio gas plants, and wherever a combustible gas-air mixture or combustible dust may occur
Features
• Color coding and pin configuration
makes it physically impossible to
mate plugs and receptacles of
different voltages and current ratings
• Interlocked switch mechanism
prevents accidental removal of plug
from receptacle under load
• Horsepower rated disconnect switch
• Dust caps* included with 20A and
30A plugs as standard
V S I S E R I E S P L U G S & S W I T C H E D R E C E P TA C L E S
DESCRIPTION
AC VOLTAGE AND
COLOR CODE
2 Pole
3 Wire
3 Pole
4 Wire
4 Pole
5 Wire
CATALOG NUMBER
• No seal required within Class I, Division
2 applications.
• Provision for up to two optional auxilliary
contact blocks, useful for signaling circuits or starter coils.3
• Dimensional information - page PR16.
PARTS AND ACCESSORIES 3
PART N U M B E R
Auxiliary Contact Block NC, A6004
VSIAUXNC
Auxiliary Contact Block NO, A6004
VSIAUXNO
410A rating for one auxiliary block; 5A if two are
used. Position noted (NC or NO) is when main
switch is off.
30 AMP2
20 AMP1
PLUG
RECEPTACLE
RECEPTACLE
PLUG
125 Yellow
VSI20R304
VSI20P304
—
—
250 Blue
VSI20R306
VSI20P306
—
—
480 Red
VSI20R307
VSI20P307
—
—
3 Ø 250 Blue
VSI20R409
VSI20P409
VSI30R409
VSI30P409
3 Ø 480 Red
VSI20R407
VSI20P407
VSI30R407
VSI30P407
3 Ø 600 Black
VSI20R405
VSI20P405
VSI30R405
VSI30P405
3 ØY 120/208 Blue
VSI20R509
VSI20P509
VSI30R509
VSI30P509
VSI30P507
Snap into side(s) of terminal block
VSI30P505
3 ØY 347/600 Black
VSI30R505
VSI20P505
VSI20R505
1VSI 20A devices are compatible with prior 16A models. However, the rating of the loweramperage will apply.
2VSI 30A devices are compatible with prior 32A models. Ratings of the lower amperagewill apply.
Dust caps shall be installed on plugs with receptacle cover closed when the plug is not engaged in the receptacle.
3 ØY 277/480 Red
VSI20R507
VSI20P507
VSI30R507
*
T E C H N I C A L D ATA
T E C H N I C A L D ATA
RECEPTACLE
ENCLOSURE MATERIAL
AMBIENT TEMPERATURE,T a
TERMINAL CAPACITY
20 AMP
30 AMP
POLYAMIDE
-30°C (-22°F) TO +55°C (131°F)
2 wires, rated 75°C (Ta < 45°C) or 90°C (Ta > 45°C)
14-8 AWG
16-10 AWG
3-phase
SWITCH RATING (HORSEPOWER) 1-phase
3-phase
—
1.5 HP
120 VAC
—
10 HP
3 HP
240 VAC
5 HP
20 HP
5 HP
480 VAC
10 HP
25 HP
600 VAC
15 HP
CLASS J - size per NEC/CEC requirement
LINE SUPPLY FUSE
1” NPT
3/4” NPT
BOTTOM ENTRY
30 AMP
PLUG
20 AMP
POLYAMIDE
ENCLOSURE MATERIAL
TERMINAL CAPACITY 1 wire, rated 75°C (Ta < 45°C) or 90°C (Ta > 45°C)
14-8 AWG
16-10 AWG
0.6” - 1.1”
CORD OUTER DIA.
0.3” - 0.8”
PR15
V E R S A M AT E ® S E R I E S • P L U G S A N D R E C E P TA C L E S
V S I N O N - M E TA L L I C P L U G S A N D S W I T C H E D R E C E P TA C L E S
Class I, Div. 2, Groups A,B,C,D
Class I, Zones 1 & 2, Groups llC, llB, llA
AEx de IIC T6
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 3, 4, 4X, IP66
FM
File 3014299
APPROVED
Certified - File LR240743
See files for details or call Killark
F E AT U R E S - S P E C I F I C AT I O N S
• When VSI Series is installed in Class
II Div. 1 & 2 locations, dust caps for
plugs are required. See ordering
information below
Applications
• For use in hazardous and corrosive
environments such as refineries,
chemical plants, water treatment and
bio gas plants, and wherever a combustible gas-air mixture or combustible dust may occur
Features
• Color coding and pin configuration
makes it physically impossible to
mate plugs and receptacles of
different voltages and current ratings
• No seals required within Class I, Div.
2 applications
V S I S E R I E S P L U G S & S W I T C H E D R E C E P TA C L E S
DESCRIPTION
3 Pole
4 Wire
4 Pole
5 Wire
Dimensional Information
• See page PR16
PLUG DUST CAP
CATALOG NUMBER
63 AMP
AC VOLTAGE AND
PLUG
COLOR CODE
RECEPTACLE
• Interlocked switch mechanism
prevents accidental removal of plug
from receptacle under load
• Horsepower rated disconnect switch
includes 1 auxiliary contact (late
make, early break) for signaling circuits.
• 63A, 125A models
FOR PLUG TYPE
125 AMP
CATALOG NUMBER
VSI63P4__
VSI63801140
RECEPTACLE
PLUG
VSI63P5__
VSI63801140
VSI125P4__
VSI125801140
VSI125P5__
VSI125801140
3 Ø 250 Blue
VSI63R409
VSI63P409
VSI125R409
VSI125P409
3 Ø 480 Red
VSI63R407
VSI63P407
VSI125R407
VSI125P407
3 Ø 600 Black
VSI63R405
VSI63P405
VSI125R405
VSI125P405
3 ØY 120/208 Blue
VSI63R509
VSI63P509
VSI125R509
VSI125P509
3 ØY 277/480 Red
VSI63R507
VSI63P507
VSI125R507
VSI125P507
Dust cap shall be installed on the plug when
the plug is not engaged in the receptacle.
VSI63P505
VSI125R505
VSI125P505
VSI63R505
VSI non-metallic devices NOT intermateable with Versamate® NEC metallic series.
3 ØY 347/600 Black
T E C H N I C A L D ATA
T E C H N I C A L D ATA
RECEPTACLE
ENCLOSURE MATERIAL
AMBIENT TEMPERATURE,T a
TERMINAL CAPACITY
SWITCH RATING (HORSEPOWER)
120 VAC
240 VAC
480 VAC
600 VAC
LINE SUPPLY FUSE
BOTTOM ENTRY
125 AMP
63 AMP
FIBER REINFORCED POLYESTER
-20°C (-4°F) TO +40°C (104°F)
2 wires, 90°C rated
1/0-3/0 AWG
6-1/0 AWG
3-phase
3-phase
20 HP
10 HP
40 HP
20 HP
100 HP
40 HP
125 HP
60 HP
CLASS J - size per NEC/CEC requirement
2” NPT
1-1/2” NPT
PLUG
ENCLOSURE MATERIAL
TERMINAL CAPACITY
CORD OUTER DIA.
125 AMP
POLYAMIDE
1 wire, 90°C rated
6-1/0 AWG
10-4 AWG
1.2” - 2”
0.94” - 1.4”
63 AMP
PR
V S I N O N - M E TA L L I C P L U G S A N D S W I T C H E D R E C E P TA C L E S
6.9” (176 mm)
O.D. 3” (76 mm)
(6 mm)
.24”
(6 mm)
4.0” (103 mm)
4.5” (115 mm)
3.66” (93 mm)
6.6” (168 mm)
O.D. 2.4”
(60 mm)
RECEPTACLE 20A
3 POLE - 4 WIRE AND 4 - POLE 5 WIRE
PLUG 20A
4.9” (124 mm)
7.4” (188 mm)
O.D. 3.9” (99 mm) - 4 Wire
O.D. 4” (102 mm) - 5 Wire
8.03” (204 mm)
.24”
(6 mm)
11.1” (281 mm)
.47” (12 mm)
5.9” (150 mm)
.24”
(6 mm)
RECEPTACLE 20A
2 POLE - 3 WIRE
4.8” (123 mm)
8.15” (207 mm)
O.D. 2.8”
(72 mm)
5.3” (135 mm)
RECEPTACLE 30A
3 POLE - 4 WIRE AND 4 POLE - 5 WIRE
PLUG 30A
2.7”
(69.5 mm)
7.1”
(180 mm)
10.6”
(268.5 mm)
19.4”(493 mm)
21.8”
(553 mm)
8.7”
(220 mm)
.43”
(11 mm)
12.0”
(296 mm)
4.9”
(125 mm)
RECEPTACLE & PLUG 63A
3 POLE - 4 WIRE AND 4 POLE - 5 WIRE
.8”
(20.5 mm)
.51”
(13 mm)
4.4”
(112 mm)
8.3”
(211 mm)
3.3” (84 mm)
.35”
(9 mm)
.43”(11 mm)
.35”(9 mm)
13.5”(342 mm)
16”
(407 mm)
6”
(152 mm)
7.12” (181 mm)
12.2”
(310.5 mm)
3.2”
(82 mm)
10.7”
(270 mm)
RECEPTACLE & PLUG 125A
3 POLE - 4 WIRE AND 4 POLE - 5 WIRE
3.8” (96 mm)
4.13” (105 mm)
.47” (12 mm)
4.1” (104 mm)
4.9” (125 mm)
5.9” (150 mm)
9.13” (232 mm)
.24”
NOTE: Drawings are not to scale
9.8” (248 mm)
6.25” (159 mm)
.47” (12 mm)
.24”
(6 mm)
Dimensions
3.7” (94 mm)
4.52” (115 mm)
.24”
(6 mm)
PR16
Download