Adjustable Range Reflective Photoelectric Sensor

advertisement
369
Adjustable Range Reflective Photoelectric Sensor
EQ-500 SERIES
FIBER
SENSORS
Related Information
■■General terms and conditions............ F-17
Glossary of terms / General precautions..........P.1359~ / P.1405
Amplifier Built-in
Multi-voltage
■■Sensor selection guide................... P.283~
■■China’s CCC mark......................... P.1409
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Conforming to Low Voltage
and EMC Directive
MICRO
PHOTOELECTRIC
SENSORS
(
DC-voltage type conforms
to EMC directive only
)
Recognition
AREA
SENSORS
Certified
LIGHT
CURTAINS
(Multi-voltege type only)
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
panasonic-electric-works.net/sunx
Long range sensing capability to 2.5 m 8.202 ft
Stable sensing unaffected by color or gloss
Long sensing range
Impervious to variations color or angle
An adjustable range to 2.5 m 8.202 ft allows plenty of
space for installation.
1 m 3.281 ft sensing range type also available. Adjust
the volume easily to suit your needs when using at close
range.
The optical system has been optimized. Since the
sensor is hardly influenced at all by angles or the gloss
of objects compared to the previous model, it is possible
to detect both white objects and black objects at almost
a constant distance.
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
CX-400
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
Hardly affected by background objects
The difference in sensing range between white non-glossy
paper and gray non-glossy paper (lightness: 5) is approx 5%
when set at a distance of 2 m 6.562 ft.
Because the sensor doesn’t detect objects outside the
preset sensing field by using the 2-segment photodiode
adjustable range system, it will not malfunction even if
someone walks behind the sensing object or machines
or conveyors are in the background.
Note: Please note that malfunction may occur when there are specular
objects or objects with a mirror-like surface in the background.
Refer to the “PRECAUTIONS FOR PROPER USE” section.
MOUNTING
OPERABILITY
Convenient terminal block type
An easy to set adjuster with indicator
Cabling enabled
by way of a
terminal block
that eliminates
waste.
Equipped with a 2-turn adjuster with indicator, making it
easy to set for short or long distances.
Terminal block
Distance adjuster
(2-turn)
Adjuster
indicator
Conduit connector
RX-LS200
RX
OFF-delay timer
adjuster (Note)
RT-610
ON-delay timer
adjuster (Note)
Note: For EQ-5□T only.
Adjustable Range Reflective Photoelectric Sensor
370
EQ-500 SERIES
APPLICATIONS
FIBER
SENSORS
Level check within the hopper
The distance to the object can be set
to enable residual amount sensing in
the hopper regardless of color.
Confirmation of the passage of
packages on a conveyor belt
LASER
SENSORS
Can accurately detect packages even
if they vary in
size and color.
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
VARIETIES
Equipped with both NPN and PNP outputs EQ-51□
EQ-50□
Multi-voltage
We’ve added a DC-voltage type
with NPN and PNP transistor
outputs all in one sensor. Its
BGS / FGS function controls
any background effects for more
stable sensing.
Because it can function with 24 to 240 V AC and 12 to
240 V DC, almost any power supply anywhere in the
world will do.
Convenient timer function models
•Operation: ON-delay, OFF-delay
•Timer period: 0
.1 to 5 sec.
(individual setting possible)
WIRE-SAVING
SYSTEMS
STATIC CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FUNCTIONS
EQ-51□
BGS / FGS functions make even the most challenging settings possible!
The BGS function is best suited for background not present
The FGS function is best suited for background present
When object and background are separated
BGS (Background suppression) function
When object and background are close
together
When the object is glossy or uneven
FGS (Foreground suppression) function
The sensor judges that an object is
present when light is received at position
A of the light-receiving element (2-segment
element).
This is useful if the object and background
are far apart.
Not affected if the background color changes
or someone passes behind the conveyor.
OFF
The sensor judges that no object is present
when light is received at position B of the light
receiving element (2-segment element) (The
conveyor is detected). This function is useful
if the object and the background are close
together or if the object is glossy or uneven.
However, sensing is impossible if there is no
background (conveyor, etc.).
OFF in this condition only
ON
Light received at
element A
Light received at element
B or light not received
Element A
Background
SIMPLE
WIRE-SAVING
UNITS
MEASUREMENT
SENSORS
Types with an ON-delay / OFF-delay timer available.
OFF-delay, e.g. useful when the response of the
connected device is slow, ON-delay, e.g. useful to detect
objects that take a long time to move.
Object present
OFF
ON
Element B
Object
Setting distance
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
CX-400
EX-20
For glossy
object
EX-30
ON
EX-40
Element A
CX-440
Emitting
element
EQ-30
Lens
Setting
distance
Conveyor
Light received at element B
A conveyor or other
background must be present.
FA COMPONENTS
EX-10
ON in all other conditions
Object absent
Element B
Moving object
in the back
SENSOR
OPTIONS
Conveyor
Light received
at element A
Note: Refer to “BGS / FGS function” of “PRECAUTIONS FOR PROPER USE” for operation of BGS / FGS function.
Conveyor
Light is not received at
element B, so an object
is judged to be present
EQ-500
MQ-W
RX-LS200
RX
RT-610
371
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Adjustable Range Reflective Photoelectric Sensor
EQ-500 SERIES
ENVIRONMENTAL RESISTANCE
Little affected by contamination on lens
Waterproof
Even if the lens surface gets
somewhat dirty from dust
particles, there is very little
change in the operation field,
by usage adjustable range
system.
IP67 protection
permits use in
environments where
water may splash.
Note: However, take care
that if it is exposed to
water splashes during
operation, it may detect a
water drop itself.
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
ORDER GUIDE
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Type
Appearance
Sensing range
WIRE-SAVING
SYSTEMS
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
With timer
EQ-501T
EQ-502
UV
CURING
SYSTEMS
Selection
Guide
Amplifierseparated
CX-400
Relay contact 1a
–
ON-delay / OFF-delay timer
(Timer period: 0.1 to 5 sec.)
–
With timer
.1 to 2.5 m
0
0.328 to 8.202 ft
NPN
open-collector
transistor
EQ-511T
12 to 24 V DC
±10 %
EQ-512
.1 to 1.0 m
0
0.328 to 3.281 ft
ON-delay / OFF-delay timer
(Timer period: 0.1 to 5 sec.)
PNP
open-collector
transistor
Equipped with
2 outputs
–
ON-delay / OFF-delay timer
(Timer period: 0.1 to 5 sec.)
EQ-512T
OPTION
Amplifier
Built-in
Power Supply
Built-in
ON-delay / OFF-delay timer
(Timer period: 0.1 to 5 sec.)
EQ-511
DC-voltage
MACHINE
VISION
SYSTEMS
24 to 240 V AC
±10 %
or
12 to 240 V DC
±10 %
EQ-502T
With timer
FA
COMPONENTS
Timer function
–
.1 to 1.0 m
0
0.328 to 3.281 ft
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Output
EQ-501
Multi-voltage
STATIC
CONTROL
DEVICES
Supply voltage
.1 to 2.5 m
0
0.328 to 8.202 ft
With timer
MEASUREMENT
SENSORS
Model No.
Designation
Model No.
Description
Sensor mounting
bracket
MS-EQ5-01
Foot / back angled mounting bracket
Sensor mounting bracket
•MS-EQ5-01
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
Two M5 (length 30 mm 1.181 in)
screws with washers and two
nuts are attached.
Adjustable Range Reflective Photoelectric Sensor
EQ-500 SERIES
SPECIFICATIONS
FIBER
SENSORS
Multi-voltage
Type
Item
Model No.
With timer
EQ-501
EQ-501T
LASER
SENSORS
DC-voltage
With timer
EQ-502
EQ-502T
With timer
EQ-511
EQ-511T
With timer
EQ-512
EQ-512T
Adjustable range (Note 2,3)
0.2 to 2.5 m 0.656 to 8.202 ft
0.2 to 1.0 m 0.656 to 3.281 ft
0.2 to 2.5 m 0.656 to 8.202 ft
0.2 to 1.0 m 0.656 to 3.281 ft
Sensing range (at max. setting distance) (Note 3)
0.1 to 2.5 m 0.328 to 8.202 ft
0.1 to 1.0 m 0.328 to 3.281 ft
0.1 to 2.5 m 0.328 to 8.202 ft
0.1 to 1.0 m 0.328 to 3.281 ft
Hysteresis (Note 3)
Supply voltage
Power / Current consumption
Output
10 % or less of operation distance
24 to 240 V AC ±10 % or 12 to 240 V DC ±10 %
Ripple P-P 10 % or less
12 to 24 V DC ±10 % Ripple P-P 10 % or less
AC: 4 VA or less AC: 5 VA or less AC: 4 VA or less AC: 5 VA or less
DC: 3 W or less DC: 4 W or less DC: 3 W or less DC: 4 W or less
45 mA or less
Relay contact 1a
• Switching capacity: 250 V AC 3 A (resistive load)
30 V DC 3 A (resistive load)
• Electrical life: 100,000 or more switching operations
(switching frequency 1,200 operations/hour)
• Mechanical life: 50 million or more switching operations
(switching frequency 18,000 operations/hour)
Output operation
Switchable either Detection-ON or Detection-OFF
Orange LED (lights up when the output is ON)
Stability indicator
Green LED (lights up under stable operating condition)
Distance adjuster
2-turn mechanical adjuster with indicator
–
Sensing mode
Timer function
–
Incorporated with
variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
–
Automatic interference prevention function
Protection
Environmental resistance
Ambient temperature
Ambient humidity
Ambient illuminance
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Emitting element
Cable length
Weight
Accessory
–
Incorporated with
variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
STATIC
CONTROL
DEVICES
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
Incorporated (Note 4)
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
IP67 (IEC)
FA
COMPONENTS
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 ℓx at the light-receiving face
2,000 V AC for one min. among supply terminals, non-supply
metal parts and relay contact output terminals, 1,000 V AC for
one min. between relay contacts
1,000 V AC for one min. between all supply terminals
connected together and enclosure
100 MΩ, or more, with 500 V DC megger among supply
terminals, non-supply metal parts and relay contact output
terminals as well as between relay contacts
20 MΩ, or more, with 250 V DC megger between all supply
terminals connected together and enclosure
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Power Supply
Built-in
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each
Amplifierseparated
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, modulated)
CX-400
2-segment photodiode
Enclosure: ABS, Front cover: Polycarbonate, Display cover: Polycarbonate
Connection method
Cable
LIGHT
CURTAINS
LASER
MARKERS
–20 to +55 °C –4 to +131 °F (No dew condensation or icing allowed), Storage: –30 to +70 °C –22 to +158 °F
Receiving element
Material
–
Incorporated with
variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
AREA
SENSORS
ENDOSCOPE
Switchable either BGS or FGS function
Incorporated with
variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
MICRO
PHOTOELECTRIC
SENSORS
MEASUREMENT
SENSORS
Incorporated
20 ms or less (For EQ-50□T depends on the setting timer period) 2 ms or less (For EQ-51□T depends on the setting timer period)
Operation indicator
PHOTOELECTRIC
SENSORS
PRESSURE /
FLOW
SENSORS
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
PNP open-collector transistor
• Maximum source current: 100 mA
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 1 V or less (at 100 mA source current)
0.4 V or less (at 16 mA source current)
–
Short-circuit protection
Response time
372
EX-20
Screw-on terminal connection
Suitable for round cable ø9 to ø11 mm ø0.354 to ø0.433 in
Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cabtyre cable.
Net weight: 100 g approx.
EX-10
Net weight: 85 g approx.
Adjusting screwdriver: 1 pc.
Notes:1)Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2)The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can also detect an object 0.1 m
0.328 ft, or more, away.
3)The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 × 200 mm 7.874 × 7.874 in) as the object.
4)Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure
to check the operation with the actual sensing object. Refer to “Automatic interference function” of “PRECAUTIONS FOR PROPER USE” for details.
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
373
Adjustable Range Reflective Photoelectric Sensor
I/O CIRCUIT AND WIRING DIAGRAMS
FIBER
SENSORS
I/O circuit diagram
Terminal No.
MICRO
PHOTOELECTRIC
SENSORS
1
LIGHT
CURTAINS
2
3
I/O circuit diagram
D
3
Tr1
ZD1
Load
Output (PNP)
Load
Output (NPN)
+
–
12 to 24 V DC
±10 %
1
2
3
4
100 mA max.
2
0V
Internal circuit
LASER
MARKERS
Users’ circuit
Symbols ... D: Reverse supply polarity protection diode
ZD1, ZD2: Surge absorption zener diode
Tr1: NPN output transistor
Tr2: PNP output transistor
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
SENSING CHARACTERISTICS (TYPICAL)
EQ-501(T) EQ-511(T)
L
0
20
0.787
CX-400
ℓ
1
3.281
Sensor
10
0
10
20
0.394
0.394
0.787
Center
Left
Right
Operating point ℓ (mm in)
0
20
0.787
L
200 × 200 mm
7.874 × 7.874 in
ℓ Non-glossy paper
Sensor
10
0
10
20
0.394
0.394
0.787
Center
Left
Right
Operating point ℓ (mm in)
1
3.281
0
EX-10
EX-30
Correlation between color
(200 × 200 mm 7.874 × 7.874 in non-glossy paper) and sensing range
EX-40
Blue
Gray
(Lightness: 8)
Gray
(Lightness: 5)
0
Green
RT-610
Red
RX
1
3.281
Brown
RX-LS200
Yellow
MQ-W
Orange
EQ-500
2.5
8.202
White
EQ-30
These bars indicate
the sensing range with
the respective colors
when the distance
adjuster is set to a
sensing range of 2.5 m
8.202 ft / 1 m 3.281 ft
long, respectively, with
white non-glossy
paper.
The sensing range
also varies depending
on material.
Sensing range L (m ft)
CX-440
2.5 m
• • • 8.202 ft
1m
• • • 3.281 ft
Correlation between sensing object size
and sensing range
Emitted beam
2.5
8.202
Distance L (m ft)
EX-20
2
6.562
Setting distance: 2.5 m 8.202 ft
ø70 mm
ø2.756 in
2.5
8.202
ø56 mm
ø2.205 in
1.5
4.921
ø42 mm
ø1.654 in
1
3.281
ø26 mm
ø1.024 in
0.5
1.640
ø20 mm
ø0.787 in
0
These bars indicate
the sensing range
with the respective
objects when the
2.5 m
• • •8.202 ft distance adjuster is
set to a sensing range
1m
• • •3.281 ft of 2.5 m 8.202 ft / 1 m
3.281 ft long,
respectively, with
white non-glossy
paper.
Black rubber
0.5
1.640
2
6.562
Plywood
200 × 200 mm
7.874 × 7.874 in
Non-glossy paper
2.5
8.202
Cardboard
Gray non-glossy paper
Lightness: 5
Sensing range L (m ft)
White nonglossy paper
Gray non-grossy
paper (Lightness: 5)
4
13.123
Gray non-glossy paper
Lightness: 5
3
9.843
Setting distance L (m ft)
1
3.281
White nonglossy paper
Correlation between material
(200 × 200 mm 7.874 × 7.874 in) and sensing range
•Setting distance: 2.5 m 8.202 ft
•Setting distance: 1 m 3.281 ft
White nonglossy paper
Sensing fields
UV
CURING
SYSTEMS
Amplifierseparated
+V
100 mA max.
4
ENDOSCOPE
Power Supply
Built-in
1
ZD2
Tr2
Sensor circuit
STATIC
CONTROL
DEVICES
Amplifier
Built-in
Terminal arrangement diagram
Terminal No.
MEASUREMENT
SENSORS
Selection
Guide
4
EQ-511(T) EQ-512(T)
WIRE-SAVING
SYSTEMS
MACHINE
VISION
SYSTEMS
3
Internal circuit
SIMPLE
WIRE-SAVING
UNITS
FA
COMPONENTS
2
Relay contact output
(1a)
4
INDUCTIVE
PROXIMITY
SENSORS
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
1
Output relay
PRESSURE /
FLOW
SENSORS
SENSOR
OPTIONS
Supply voltage
24 to 240 V AC ±10 %
or
12 to 240 V DC ±10 %
Multi-voltage
circuit
Sensor circuit
AREA
SENSORS
PARTICULAR
USE
SENSORS
Terminal arrangement diagram
Sensing range L (m ft)
PHOTOELECTRIC
SENSORS
EQ-501(T) EQ-502(T)
Setting distance L (m ft)
LASER
SENSORS
EQ-500 SERIES
2
6.562
1
3.281
White
non-glossy paper
L
Sensor
0
50
100
150
1.969
3.937
5.906
White non-glossy paper
side length a (mm in)
This curve shows
the characteristics
with the maximum
sensing range set
to 2.5 m 8.202 ft,
with white
non-glossy paper
(200 × 200 mm
7.874 × 7.874 in).
200
7.874
Adjustable Range Reflective Photoelectric Sensor
EQ-500 SERIES
374
SENSING CHARACTERISTICS (TYPICAL)
FIBER
SENSORS
EQ-502 (T) EQ-512 (T)
LASER
SENSORS
Sensor
10
0
10
20
0.394
0.394
0.787
Center
Left
Right
Operating point ℓ (mm in)
L
0
20
0.787
10
0
10
20
0.394
0.394
0.787
Center
Left
Right
Operating point ℓ (mm in)
Blue
Gray
(Lightness: 8)
Gray
(Lightness: 5)
Green
Red
Brown
Orange
White
Yellow
0.5
1.640
1m
• • •3.281 ft
0
Emitted beam
Correlation between sensing object size and sensing range
ø26 mm
ø1.024 in
1
3.281
ø20 mm
ø0.787 in
0.5
1.640
1
3.281
0.5
1.640
0
0.5 m
• • •1.640 ft
White nonglossy paper
Mounting
M5 nut
M5 (length 30 mm 1.181 in)
screw with washers
• The tightening torque
should be 0.8 N·m or less.
• Care must be taken
regarding the sensor
mounting direction with
respect to the object’s
direction of movement.
Correct
Sensor
mounting
blacket
MS-EQ5-01
(Optional)
Correct
Incorrect
This curve shows the
characteristics with
the maximum
sensing range set to
1 m 3.281 ft, with
white non-glossy
paper
(200 × 200 mm
7.874 × 7.874 in).
L
50
100
150
1.969
3.937
5.906
White non-glossy paper
side length a (mm in)
PRECAUTIONS FOR PROPER USE
•Never use this product as a sensing device
for personnel protection.
•In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
200
7.874
•When a specular body is present below the sensor, use the
sensor by tilting it slightly upwards to avoid faulty operation.
Incorrect
Correct
Specular
face
Tilt
•This product is not easily affected by the reflected light
intensity since this sensor is the adjustable range reflective
type. When the reflected light intensity is remarkably low,
the sensing range may be affected. In that case, mount the
sensor, while checking light-up of the stable indicator (green).
•The mounting screws of the terminal cover and display cover
should certainly be tightened to maintain water-resistance;
the tightening torque of the screws should be 0.3 to 0.5 N·m.
Automatic interference prevention function
Sensing object
Sensing object
Sensing object
•When detecting a specular object (aluminum or copper foil,
etc.) or an object having a glossy surface or coating, please
note that there are cases when the object may not be detected
due to a change in angle, wrinkles on the object surface, etc.
• If a specular body is present in the background, faulty operation may
be caused due to a small change in the angle of the background
body. In that case, install the sensor at an inclination and confirm the
operation with the actual sensing object.
0
1
3.281
Interference
prevented area
L mm in
or more
L mm in
or more
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
L mm in
or more
0
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
EX-10
EX-20
EX-30
EX-40
2
6.562
L mm in
or more
20 40 60 80
0.787 1.575 2.362 3.15
Mounting interval L (mm in)
SENSOR
OPTIONS
CX-400
3
9.843
Setting distance (m ft)
Setting distance (m ft)
3
9.843
1
3.281
PARTICULAR
USE
SENSORS
FA
COMPONENTS
Specular
face
•When the sensors are mounted closely, use them in the
interference prevented area, as shown below.
Do not make the sensor
detect an object in this
direction because it may
cause unstable operation.
INDUCTIVE
PROXIMITY
SENSORS
LASER
MARKERS
Refer to General precautions.
2
6.562
PRESSURE /
FLOW
SENSORS
WIRE-SAVING
SYSTEMS
Sensor
0
LIGHT
CURTAINS
SIMPLE
WIRE-SAVING
UNITS
Setting distance: 1 m 3.281 ft
Distance L (m ft)
Sensing range L (m ft)
These bars indicate
the sensing range with
the respective colors
when the distance
adjuster is set to a
sensing range of 1 m
3.281 ft / 0.5 m 1.640 ft
long, respectively, with
white non-glossy
paper.
The sensing range
also varies depending
on material.
1
3.281
ℓ
Sensor
Correlation between color (200 × 200 mm 7.874 × 7.874 in non-glossy paper) and sensing range
These bars indicate
the sensing range with
the respective objects
1m
• • •3.281 ft when the distance
adjuster is set to a
0.5 m sensing range of 1 m
• • •1.640 ft 3.281 ft / 0.5 m 1.640 ft
long, respectively, with
white non-glossy
paper.
0.5
1.640
Black rubber
0
20
0.787
ℓ
AREA
SENSORS
Plywood
L
0.2
0.656
200 × 200 mm
7.874 × 7.874 in
Non-glossy paper
0.5
1.640
1
3.281
Sensing range L (m ft)
200 × 200 mm
7.874 × 7.874 in
Non-glossy paper
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Cardboard
1
3.281
0.6
1.969
0.4
1.312
Gray non-glossy paper
Lightness: 5
Gray non-grossy
paper (Lightness: 5)
White nonglossy paper
Gray non-glossy paper
Lightness: 5
Correlation between material
(200 × 200 mm 7.874 × 7.874 in) and sensing range
Sensing range L (m ft)
White nonglossy paper
Setting distance L (m ft)
Setting distance L (m ft)
0.8
2.625
•Setting distance: 1 m 3.281 ft
White nonglossy paper
Sensing fields
•Setting distance: 0.5 m 1.640 ft
CX-440
Interference
prevented area
50 100 150 200 250
1.969 3.937 5.906 7.874 9.843
Mounting interval L (mm in)
•Note that the detection may be unstable depending on
the mounting conditions or the sensing object to be used.
In the state that this product is mounted, be sure to check
the operation with the actual sensing object to be used.
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
375
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
Adjustable Range Reflective Photoelectric Sensor
EQ-500 SERIES
PRECAUTIONS FOR PROPER USE
Refer to General precautions.
Wiring
Part description
•Check all wiring before applying power since incorrect
wiring may damage the internal circuit. Also, carefully
tighten the terminal screws so that the wires of adjacent
terminals do not touch.
•The mounting hole for the terminal cover fixing screws
inclines 70 degrees to the terminal cover, as shown in the
figure below.
To avoid damaging this product or screw, take care when
tightening or loosening a screw.
Screw for terminal cover fixing
INDUCTIVE
PROXIMITY
SENSORS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
•To maintain water-resistance, the cable should have
an outer diameter between ø9 to ø11 mm ø0.354 to
ø0.433 in with a smooth covering material that allows the
attached conduit connector to be securely tightened; the
tightening torque of the screw should be of 1.5 to 2.0 N·m.
•If an external surge voltage exceeding 4 kV is impressed
(DC-voltage type: 1 kV), the internal circuit will be
damaged, and a surge suppressing element should be
used.
•Prepare the cable end as shown below.
Conduit connector construction and cabling
37 mm
1.457 in
PLC /
TERMINALS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
ON-delay timer adjuster (Note 2)
Operation mode switch
Detection-OFF mode is obtained when the switch
is turned fully counterclockwise (D side).
Note: T
urn the operation mode switch gradually and lightly with the attached
screwdriver. Turning with excessive strength will cause damage to the
adjuster.
DC-voltage type
L-ON / D-ON mode
BGS / FGS mode
Timer mode
Not used
Output
Gland packing (Note)
25 mm
0.984 in
Gland
Note: When assembling the conduit connector, pay attention to the direction
of the gland packing.
Furthermore, in order to maintain water-resistance, fit the gland
packing such that the seating surface of the gland packing contacts
the packing holder part of the terminal cover evenly.
•The size of conduit is M20 × 1.5 mm 0.787 in.
•If pressure terminals are to be used, affix the connected
pressure terminals to a terminal (M3.5 screw).
Dimensions of the suitable crimp terminals
Round type
Description
Detection-ON mode is obtained when the switch
is turned fully clockwise (L side).
Conduit connector
Power Supply
Built-in
(Unit: mm in)
EX-30
EX-40
•DC-voltage type sensor incorporates BGS / FGS function.
Select either the BGS or FGS function depending on the
positions of the background and sensing object.
•BGS / FGS function is set with the operation mode
switch.
•FGS function is used when the sensing object contacts
the background (conveyor, etc).
•Depends on a selection of either BGS or FGS function,
the output operation changes as follows.
Y-shaped type
ø 3.6
ø 0.142
or more
7.5 0.295
or less
22 0.866
or less
10 0.394
or less
3.6 0.142
or more
7 0.276
or less
17 0.669
or less
(After crimping)
7.5 0.295
or less
Setting distance
22 0.866
or less
10 0.394
or less
Non-detectable area
7 0.276
or less
17 0.669
or less
(After crimping)
L-ON
BGS
D-ON
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
D
FGS
Timer ON
N.C.
Detectable range
EX-10
EX-20
L
BGS
OFF
N.C.
BGS / FGS function (DC-voltage type only)
Amplifierseparated
CX-400
Operation mode switch (Note 1)
Notes: 1) T
he operation mode switch of the DC-voltage type is the DIP switch.
Refer to ‘DC-voltage type’ of ‘Operation mode switch’ for details.
2) Incorporated on EQ-5□T only.
Power supply
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Adjuster indicator
Operation indicator (Orange)
Multi-voltage type (L-ON / D-ON mode only)
Screwdriver
SENSOR
OPTIONS
WIRE-SAVING
SYSTEMS
OFF-delay timer adjuster (Note 2)
Operation mode switch
PARTICULAR
USE
SENSORS
SIMPLE
WIRE-SAVING
UNITS
Stability indicator (Green)
Distance adjuster (2-turn)
Note: Use crimp terminals with insulating sleeves.
Recommended crimp terminal: Nominal size 1.25 × 3.5 0.049 × 0.138.
•The tightening torque for the terminal screws should be
0.3 to 0.5 N·m.
L-ON
FGS
D-ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Adjustable Range Reflective Photoelectric Sensor
EQ-500 SERIES
PRECAUTIONS FOR PROPER USE
Timer function (EQ-5□T only)
376
Refer to General precautions.
LASER
SENSORS
Stability indicator
•EQ-5□T incorporates an OFF-delay timer, which is
useful when the response of the connected device is
slow, etc., and an ON-delay timer, which is useful for
detecting objects that move slowly, for example.
•The OFF-delay and ON-delay timers can be used
simultaneously.
•For DC-voltage type, set the DIP switch for the timer
mode to ‘Timer ON’ side.
•Since the EQ-500 series uses a 2-segment photodiode
as its receiving element, and sensing is done based
on the difference in the incident beam angle of the
reflected beam from the sensing object, the output and
the operation indicator (orange) operate according to
the object distance.
Furthermore, the stability indicator (green) shows the
margin of the setting distance.
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
Time chart
Operation
FIBER
SENSORS
Sensing
condition
Setting distance
Detection
Nondetection
ON
Detection
normal operation
OFF
Detection ON-delay
Sensing object
ON (Lights up)
Output (Operation indicator)
(In case of Detection-ON)
OFF (Lights off)
ON
T
T
T
T
Stable operating Lights up
condition
Lights off
Unstable
operating condition
Stability indicator
OFF
Detection OFF-delay
INDUCTIVE
PROXIMITY
SENSORS
OFF
WIRE-SAVING
SYSTEMS
ON
Detection ON / OFF-delay
T
T
OFF
ON
Non-detection
normal operation
OFF
ON
Non-detection ON-delay
T
T
T
OFF
ON
Non-detection OFF-delay
T
Non-detection
ON / OFF-delay
T
MEASUREMENT
SENSORS
Others
•Do not use during the initial transient time (50 ms) after
the power supply is switched on.
•Its distance adjuster is mechanically operated. Do not
drop; avoid other shocks.
ON
HUMAN
MACHINE
INTERFACES
Timer period: T = 0.1 to 5 sec. (variable)
The CAD data in the dimensions can be downloaded from our website.
Sensor
Assembly dimensions with sensor mounting bracket
MS-EQ5-01 (Optional) (Foot angled mounting)
Adjuster indicator
Center of beamemitting
(Center of sensing)
2
0.079
UV
CURING
SYSTEMS
OFF-delay timer adjuster (Note 2)
29
1.142
ON-delay timer adjuster (Note 2)
6.5
0.256
Operation indicator (Orange)
26
1.024
MACHINE
VISION
SYSTEMS
Operation mode switch (Note 1)
Distance adjuster (2-turn)
Beamreceiving part
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
EQ-501(T) EQ-502(T) EQ-511(T) EQ-512(T)
Stability indicator (Green)
ENDOSCOPE
PLC /
TERMINALS
OFF
DIMENSIONS (Unit: mm in)
STATIC
CONTROL
DEVICES
LASER
MARKERS
OFF
T
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Stable operating
condition
ON
PARTICULAR
USE
SENSORS
(30.5)
(1.201)
ø6.5
ø0.256
3-M5 nut seats
(on both sides)
68
2.677
(10)
(0.394)
3-ø5.1 ø0.201
mounting holes
4
0.157
6.5
0.256
17.5
0.689
58
(10)
2.283
(0.394)
2-M5 (length 30 1.181) screws
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
CX-400
EX-10
Center of beamemitting
(Center of sensing)
68 58
2.677 2.283
EX-20
58
2.283 88
3.465
22
0.866
5
0.197
5
0.197
30
1.181
58
2.283
Notes:1)The operation mode switch of the DC-voltage type is the DIP
switch.
2)For EQ-5□T only.
37
1.457
18
0.709
26
1.024
29
1.142
5
0.197
58
2.283
78
3.071
t2
t 0.079
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
Material: Cold rolled carbon steel (SPCC)
RX-LS200
Two M5 (length 30 mm 1.181 in) screws with washers and two nuts are attached.
RX
RT-610
Download