Project: Type: Archer LED Qty: Patient Room Wall Light S P EC IF ICATI ONS I n terior ARCHER LED SPECIFICATIONS The Archer bed light provides versatility with optional sequential switching for patient room ambient and task lighting. The sleek housing profile echoes the Chrysalite and can be used together to create a complementary look in a lighting design. Multiple lamping and switching options allow this fixture to be used in a wide array of applications. As a bed light, placement above the patient on the headwall delivers optimal distribution of light for reading and also comfortable ambient illumination. If a low voltage controller is included (optional), light levels can be adjusted via the nurse call system or using a separate pendant pillow switch (optional). This fixture is also a good choice for guest lighting. • Delivers multiple light levels for patient: indirect, direct, both • Separate mounting plate makes installation easy; mount rigid but lightweight plate to wall and then install fixture • Low voltage controller (option) allows patient control from nurse call system or separate pillow switch (option) • Tool-free access to ballast compartment while fixture remains on wall • Single-piece extruded aluminum body for extreme durability • Entirely serviceable without removal from wall Construction Extruded aluminum housing Die-cast aluminum handles High impact acrylic lenses, UV treated to prevent yellowing with age Polyester powder coat finish; anti-microbial powder coat finish available Wall mount brackets included. Packaged separately. Voltage 120V Dimming 0-10V dimming standard Switching Line voltage switching (by others) Low voltage controller (optional) for patient control of up and down light sequentially from nurse call system or pillow switch (optional) 2-position pull chain for on/off control or 4-position pull chain for sequential control of up and down light (optional, 120V only) Color Quality >80 CRI Driver Roal Strato RSL035-09 or equivalent Input Watts (As Tested) Top and bottom mode 2U2D configuration, 4ft fixture – 102 WATTS Top mode 2U2D configuration, 4ft fixture - 51 WATTS Listings CSA certified to meet US and Canadian standards. Damp location listed. Weight HPW336 – approximate shipping weight 20 lbs. HPW348 – approximate shipping weight 30 lbs. Light Output (As Tested) Top and bottom mode 2U2D configuration, 4ft fixture - 10860 lumens Top mode 2U2D configuration, 4ft fixture - 5490 lumens Source Nichia LED chips (or equivalent) mounted on linear boards CATALOG NUMBER Life Estimate 50,000 hours* *LED life projection based on IES TM-21 and IES LM-80 Warranty 5-year limited warranty. Complete warranty terms located at: www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Example: HPW348 120 LED35 2U2D LV LCR AM Series HPW336 HPW348 Archer 3ft in Length Archer 4ft in Length Voltage Lamping Type Lamping 120 LED27 LED30 LED35 LED40 2U1D 2U2D 1U1D 1U2D 120V 2700K LED 3000K LED 3500K LED 4000K LED Switching Config LV LV1L1 LV1R1 LV2L1 LV2R1 S2L2 S2R2 S2C2 Low Voltage Controller - Sequential Switching LVC with Pillow Switch for Down Light on Left LVC with Pillow Switch for Down Light on Right LVC with Pillow Switch on Left - Sequencing Up + Down Light LVC with Pillow Switch on Right - Sequencing Up + Down Light On/Off Pull Chain on Left (top & bottom) On/Off Pull Chain on Right (top & bottom) On/Off Pull Chain on Center (top & bottom) 0U1DMT 0U2DMT 1U0DMB 2U0DMB 2 Rows LEDs Up, 1 Row LEDs Down 2 Rows LEDs Up, 2 Rows LEDs Down 1 Row LEDs Up, 1 Row LEDs Down 1 Row LEDs Up, 2 Rows LEDs Down Only 1 Row LEDs Down with Top Plate 2 Rows LEDs Down with Top Plate Only 1 Row LEDs Up with Bottom Plate 2 Rows LEDs Up with Bottom plate Option S2LDL1,2 S2RDL1,2 S2CDL1,2 S4L1,2 S4R1,2 S4C1,2 SX On/Off Pull Chain on Left (bottom only) On/Off Pull Chain on Right (bottom only) On/Off Pull Chain on Center (bottom only) 4-Position Pull Chain on Left 4-Position Pull Chain on Right 4-Position Pull Chain on Center No Switch LCL3 LCR3 LCLHW3 LCRHW3 BD Finish 3W LED Chart Light with Switch on Left 3W LED Chart Light with Switch on Right 3W LED Chart Light “Hard Wired” Left 3W LED Chart Light “Hard Wired” Right Bed-Stop Switch FW AM CC4 Flat White (standard) Anti-Microbial White Custom Color Notes are on following page. Healthcare Lighting • 888-834-5684 • www.healthcare-lighting.com ©2015-2016 Acuity Brands Lighting, Inc. All Rights Reserved. “Healthcare Lighting” is a registered trademark of Acuity Brands Lighting. Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Rev. 08/31/16 HPW3LED 1 Project: Archer LED Type: Patient Room Wall Light Qty: S P EC IF ICATI ONS I n terior ARCHER LED Notes 1 2 3 4 Switching: S2 and S4 options are compatible with 120V only For pull chain and pillow switch, specify “left” or “right” as viewed facing the head wall 3W LED chart light (option) always installed opposite end from pull chain or pillow switch Custom color requires factory pricing DIMENSIONS BLOCKING BY OTHERS Fixture HPW348 LED 4.22 HPW336 LED NOMINAL LENGTH 48” 36” ACTUAL LENGTH 49.56” 37.56” 6.85 SIDE VIEW CROSS SECTION MOUNTING INFORMATION • • • • Installation is made easy by the incorporation of a separate mounting plate (blocking by others). After the plate is mounted to the wall the fixture can be quickly connected and hung. It is the responsibility of the party installing the fixture to select appropriate fasteners that are suitable for the wall material and construction. It is the responsibility of the person inst alling the light fixture to ensure that the materials, hardware and building structural members that are selected will support the light fixture(s) and that they meet all applicable building and safety codes. • Complete electrical connections according to the wiring diagram on ballast tray, following all applicable building codes and regulations. HPW336 LED HPW348 LED FIXTURE MOUNTING STUDS SEE INSTALLATION INSTRUCTIONS 3 " 8 615 16" 7" 6" 7" 7" 7" 613 16" 615 16" 1 " HOLES FOR 4 BOLTS OR #14 WOOD SCREWS APPLIES TO ALL PLATES 29 16" SIDE PROFILE APPLIES TO ALL PLATES 245 8" LINE VOLTAGE WIRE WAY 83 4" 81 4" 7" 613 16" 7" LINE VOLTAGE WIRE WAY LOW VOLTAGE WIRE WAY 467 16" 493 16" 185 8" 83 4" 347 16" LOW VOLTAGE WIRE WAY 373 16" Healthcare Lighting • 888-834-5684 • www.healthcare-lighting.com ©2015-2016 Acuity Brands Lighting, Inc. All Rights Reserved. “Healthcare Lighting” is a registered trademark of Acuity Brands Lighting. Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Rev. 08/31/16 HPW3LED 2 Project: Archer LED Type: Patient Room Wall Light Qty: S P EC IF ICATI ONS I n terior ARCHER LED PERFORMANCE DATA Lumen Output Electrical Load Lumen values are from photometric tests from an accredited laboratory. Data is considered to be representative of the configurations shown, within the tolerances allowed within generally accepted industry tolerances. Actual performance may differ as a result of end-user environment and application. Contact factory for performance data on any configurations not shown here Light Switch Mode top and bottom on DIRECT: bottom on INDIRECT: top on For 4ft Fixture Lumen Output 10860 lumens 5370 lumens 5490 lumens Max CD 2370 candela 2260 candela 2370 candela For 4ft Fixture Light Switch Mode Input Watts top and bottom on 102 watts DIRECT: bottom on 51 watts INDIRECT: top on 51 watts Actual performance may differ as a result of end-user environment or application PHOTOMETRICS DIRECT Test Report: 501927 HPW348-120-LED352U2D-LV1R-LCL-GLR Lumens: 4,496 Input Wattage: 63.5 Max. Candela: 2,062 H: 15º, V: 7.5º 180º 170º160º 150º 2,700 2,250 1,800 1,350 900 450 CD: 0 450 900 1,350 1,800 2,250 2,700 140º 130º 120º 110º 100º 90º 80º 70º 60º 50º - 0º H - 90º H VA: 0º 10º 20º 30º 40º Illuminance at a Distance Center Beam Height Footcandle 4.0 125.4fc 8.0 31.4fc 12.0 13.9fc 16.0 7.8fc 20.0 5.0fc INDIRECT Test Report: 501929 HPW348-120-LED352U2D-LV1R-LCL-GLR Lumens: 4,660.1 Input Wattage: 62.7 Max. Candela: 2,035 H: 10º, V: 157.5º 180º 170º160º 150º 1,700 1,417 1,133 850 567 283 CD: 0 283 567 850 1,133 1,417 1,700 140º 130º 120º 110º 100º 90º 80º 70º 60º 50º - 0º H - 90º H VA: 0º 10º 20º 30º 40º Illuminance at a Distance Center Beam Height Footcandle 4.0 0fc 8.0 0fc 12.0 0fc 16.0 0fc 20.0 0fc DIRECT & INDIRECT (All On) Test Report: 501930 HPW348-120-LED352U2D-LV1R-LCL-GLR Lumens: 9,077.8 Input Wattage: 125.7 Max. Candela: 2,062 H: 15º, V: 7.5º 180º 170º160º 150º 140º 1,700 1,417 1,133 850 567 283 CD: 0 283 567 850 1,133 1,417 1,700 130º 120º 110º 100º 90º 80º 70º 60º 50º - 0º H - 90º H VA: 0º 10º 20º 30º 40º Illuminance at a Distance Center Beam Height Footcandle 4.0 125.4fc 8.0 31.4fc 12.0 13.9fc 16.0 7.8fc 20.0 5.0fc Photometric data based on test results from an independent NIST traceable testing lab. IES data is available at www.healthcare-lighting.com. Always refer to our website for the latest IES file updates. Healthcare Lighting • 888-834-5684 • www.healthcare-lighting.com ©2015-2016 Acuity Brands Lighting, Inc. All Rights Reserved. “Healthcare Lighting” is a registered trademark of Acuity Brands Lighting. Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Rev. 08/31/16 HPW3LED 3