RY-IP44 Instructions

advertisement
#95101
0416
RY-IP44
Input/Output Network Adaptor
Programming Manual
For use with IX Series, IS-IP Series, and IPW-1A
ATTENTION:
This is the programming manual for the RY-IP44 only. Refer to the Installation and Setting
Manuals for the series being integrated with for complete installation/programming information
on each system (IX, IS-IP, IPW-1A).
Installation Requirements
Package Contents
•
•
•
•
RY-IP44
Programming Manual
6 Screw Terminal Blocks
MAC Address Label
•
•
•
General understanding of IX Series, IS-IP Series, or
IPW-1A programming
9'&SRZHUVXSSO\VROGVHSDUDWHO\
8QLTXH,3DGGUHVVIRUHDFKDGDSWRU
Overview / Description
7KH5<,3LVD%DUL[%DULRQHWZLWKSURSULHWDU\¿UPZDUHLQVWDOOHGIRUWKHGHYLFHWRIXQFWLRQZLWKWKH$LSKRQH,;
Series, IS-IP Series stations, or IPW-1A systems.
Relay outputs can be programmed to trigger for door release, upon call-in, while in communication, or while calling
and communicating.
,QSXWVFDQEHSURJUDPPHGWRWULJJHUDFDOOZLWKWKH,;RU,6,3V\VWHPVZLWKDQLQYDOLGFDUGVZLSHPRWLRQGHWHFWRU
DFWLYDWLRQRUVHOHFWLYHFDOOIURPWKH,6,3'9)GRRUVWDWLRQ
7KH5<,3LVUHTXLUHGZKHQUXQQLQJ,;0RELOHDSSRQDPRELOHGHYLFH7KH5<,3ZLOOIXQFWLRQDVWKH,;6HULHV
DSSVHUYHU8SWRPRELOHGHYLFHVFDQEHHPSOR\HGSHUVHUYHU7KH5<,3ZLOODOHUWWKHPRELOHGHYLFHLILWJRHVRXW
of wireless network range.
,IRQO\XVLQJWKH5<,3IRU,;0RELOHFRQ¿JXUHWKHDGDSWRUDVVKRZQRQSDJHWKHQVNLSWRSDJH,;0RELOH
6HUYHU7KH6,)LQL¿OHLVQRWQHHGHGZKHQRQO\XVLQJWKHDGDSWRUDVWKH,;6HUYHU5HIHUWRSDJHVIRUVWHSVRQ
DGGLQJDPRELOHGHYLFHWRWKH,;6HULHVXVLQJWKH,;6XSSRUW7RRODQGIRUVHWWLQJXSWKHPRELOHGHYLFH
7KH5<,3DGDSWRULVQRWD3R(GHYLFH$GHGLFDWHG9'&SRZHUVXSSO\LVUHTXLUHG8VHWKH$LSKRQH
368/SRZHUVXSSO\VROGVHSDUDWHO\
SIF.ini File ,;6HULHVDQG,6,36HULHV6WDWLRQV2QO\
Important:
The intercom system must be fully programmed and operational prior to programming the RY-IP44 adaptor.
Create a SIF.ini file in order for the IX Series and IS-IP Series door stations and master stations to communicate with the
DGDSWRU8VHDWH[WHGLWRUSURJUDPLHQRWHSDGWRFUHDWHWKLVILOHDQGVDYHLWZLWKDLQLH[WHQVLRQ
Program Type:
Range is between 0100 and 1111 (Binary).
RY-IP44 IP Address:
IP address assigned to the RY-IP44. Must be unique for each RY-IP44.
Destination Port:
Port number assigned on the RY-IP44. The default port is 10000. This can be
VHWLQWKHUDQJHIURPWR
7KLVGHYLFHGRHVQRWXVH66/,QSXWIRUQR
SSL Y/N :
Example Text File:
Program
Type
RY-IP44
IP Address
'HVWLQDWLRQ SSL
Port
Y/N
6DYHWKH6,)¿OHZLWKDLQLH[WHQVLRQLQLPXVWEHW\SHGPDQXDOO\WRDORFDWLRQRQWKH3&EHLQJXVHGIRUSURJUDPPLQJWKH,;
6HULHVRU,6,36HULHVVWDWLRQV7KLV¿OHPXVWEHXSORDGHGWRHDFKGHYLFHDVVRFLDWHGZLWKWKH5<,3XVLQJWKHLQVWUXFWLRQV
that follow.
2 | RY-IP44 Programming Manual
IX Series: Uploading SIF.ini File
8SORDGWKH6,)LQL¿OHWRHDFK,;6HULHVVWDWLRQDVVRFLDWHGZLWKWKH5<,3DGDSWRU
! 7KH,;6XSSRUW7RRORUZHEEURZVHULQWHUIDFHFDQEHXVHGWRXSORDGWKH6,)LQL¿OHWRHDFKVWDWLRQ
/RDGLQJYLDWKH,;6XSSRUW7RROLVVKRZQLQWKHVHLQVWUXFWLRQV
Important:
7KHLQWHUFRPV\VWHPPXVWEHIXOO\SURJUDPPHGDQGRSHUDWLRQDOSULRUWRXSORDGLQJWKH6,)LQL¿OH
A. Log in to the IX Series system using the IX Support Tool.
B. Expand the Function Settings tree on the left and select SIF Integration.
C. Choose the station to be edited from the Number drop down menu then click the Select button.
' 6HOHFWWKHEnable radio button for both the CGI Integration and SIF Integration.
Click BrowseWREURZVHWRZKHUHWKHLQL¿OHLVVDYHGDQGFOLFNUpload to send to station.
E. Click UpdateWRVDYHWKHFKDQJHVIRUWKHVWDWLRQWKHQUHSHDWWKHSURFHVVIRUHDFKVWDWLRQWKDWZLOOEHDVVRFLDWHG
with the RY-IP44.
) $IWHUFRPSOHWLQJVWHSV&'DQG(IRUHDFKVWDWLRQXSORDGWKHFKDQJHV&OLFNFile, Upload Settings to Station.
Select the stations to upload to and click Start Upload.
IS-IP Series: Uploading SIF.ini File
8SORDGWKH6,)LQL¿OHWRHDFK,6,36HULHVVWDWLRQDVVRFLDWHGZLWKWKH5<,3DGDSWRU
! 1RWHWKDWWKH,3DGGUHVVIRUHDFKVWDWLRQZLOOEHXQLTXHIRU\RXUQHWZRUNVHWWLQJV
Important:
7KHLQWHUFRPV\VWHPPXVWEHIXOO\SURJUDPPHGDQGRSHUDWLRQDOSULRUWRXSORDGLQJWKH6,)LQL¿OH
A. Open a web browser and type https://[ip address]/sif in the address bar.
>LSDGGUHVV@ VWDWLF,3DGGUHVVDVVLJQHGWRWKHVWDWLRQEHLQJSURJUDPPHG
% $VHFXULW\FHUWL¿FDWHHUURUPHVVDJHZLOODSSHDU&RQWLQXHWRWKHZHEVLWH
& (QWHUWKHDGPLQLVWUDWRU,'DQGSDVVZRUG
Default ID:
Default Password:
aiphone
aiphone
' Select Transmission setting under Uploading SIF setting data from the menu on the left side of the screen.
E. Click the Upload button. A new window will open.
F.
Click the BrowseEXWWRQDQGQDYLJDWHWRWKHLQL¿OHVDYHGRQWKH3&
G. Click the Upload button. A message will appear stating the settings will not be applied until the system is updated.
H. Click Updating the system from the menu on the left. Click the Update button and the unit will update and restart
itself.
I.
Repeat this process for each door and master station associated with the RY-IP44 adaptor.
4 | RY-IP44 Programming Manual
&RQ¿JXULQJWKH5<,3DVVLJQLQJ,3DGGUHVVDQGV\VWHPXVH
7KH5<,3KDVDGHIDXOW,3DGGUHVVRI2SHQDZHEEURZVHUDQGSRLQWWKHDGGUHVVEDUWR
http://192.168.1.45IRUDFFHVVWRWKHDGDSWRU7KH¿UVWVFUHHQWRDSSHDUZLOOEHWKHDevice Status screen.
&RQ¿JXUDWLRQEXWWRQ
'LJLWDOLQSXWVWDWXV
Relay status and control.
&OLFNRQHDFK/('WRYHULI\
relay function.
Click the CONFIGURATION button to open the 'HYLFH&RQ¿JXUDWLRQ screen. This is where a unique IP Address,
Netmask, and Gateway can be assigned to the adaptor. Consult with your IT department for these settings.
Settings not utilized for Aiphone
IXQFWLRQDOLW\'RQRWDGMXVW
AIPHONE: Select the Aiphone system
type the relay is to be used with.
6(&85,7<)RUFUHDWLQJDSDVVZRUGIRU
access to the web browser interface.
The Aiphone system type that the relay is being integrated with will need to be selected. Click the AIPHONE WDE8VHWKH
drop down by System Type to select the appropriate system. Once selected, click OK. Click Reboot on the next screen to
restart the adaptor.
System Type: Select IX, IS, or IPW-1A
SIF Socket Local Port: Enter the port number
WKDWZDVDVVLJQHGLQWKH6,)LQL¿OH/HDYHDW³´
to use default 10000 port.
Username & Password: For IX/IS, enter
V\VWHP¶VXVHUQDPHDQGSDVVZRUG/HDYHEODQNLI
using default (IX = admin, IS = aiphone).
IX Mobile App Server Port: Enter the port number
that has been assigned in the IX Mobile app(s).
(QWHU³´LIGHIDXOWSRUWLVWREHXVHG
UDP Protocol Port8VHGIRU,3:$RQO\(QWHU
³´LIGHIDXOWSRUWLVWREHXVHG
5
IX Series: Relay Output Programming
The RY-IP44 has 4 relays that can be programmed to trigger while calling, while in communication, or while calling and
FRPPXQLFDWLQJZLWKDVSHFL¿FVWDWLRQ7KHUHOD\VFDQDOVREHSURJUDPPHGIRUGRRUUHOHDVH
Set the RY-IP44 for use with the IX Series (refer to page 5).
From the DEVICE CONFIGURATION screen, click APPLICATION SETUP.
$33/,&$7,216(783EXWWRQ
Relay Action options:
• 'RRU5HOHDVH1RUPDOO\2SHQ
Relay will trigger when the associated station’s door release contact is triggered.
• 'RRU5HOHDVH1RUPDOO\&ORVHG
• $FWLYHZKLOH&DOOLQJIURP6RXUFH
• $FWLYHZKLOH&RPPXQLFDWLQJ
Relay will trigger when the associated station calls or communicates.
• $FWLYHGXULQJ&DOOLQJDQG&RPPXQLFDWLQJ
}
}
The IX Series allows for door release partitioning. When the RY-IP44 relay action is set for door release, the relay
will be triggered only if door release is allowed on the station. To set door release partitioning, refer to Door Release
Settings under the Function Settings tree in the IX Support Tool.
:KHQWKHUHOD\DFWLRQLVVHWIRUWKH³'RRU5HOHDVH´RSWLRQVWKHUHOD\RQWKH5<,3ZLOOWULJJHUZKHQWKHDVVRFLDWHG
station is calling or communicating and its door release contact is triggered.
:KHQWKHUHOD\DFWLRQLVVHWIRUDQ\RIWKH³$FWLYH:KLOH´RSWLRQVWKHUHOD\ZLOOWULJJHUZKHQWKHDVVRFLDWHGVWDWLRQFDOOV
RUFRPPXQLFDWHVDWDQ\SULRULW\OHYHO
Enter the station number of the station to be associated with the relay. Select the relay condition from the Relay Action
drop down menu.
Click on Apply Settings then click RebootWRUHVWDUWWKHDGDSWRUZLWKWKHVDYHGFKDQJHV
:KHQWKHHQWHUHGVWDWLRQLVDFWLYHWKHDVVRFLDWHGUHOD\ZLOOWULJJHUEDVHGRQWKH5HOD\$FWLRQVHWWLQJV
6 | RY-IP44 Programming Manual
IX Series: Input Programming
7KH5<,3DGDSWRUKDVLQSXWVWKDWFDQEHSURJUDPPHGWRWULJJHUDFDOOLQIURPDVSHFL¿FGRRUVWDWLRQRUPDVWHUVWDWLRQWRD
VSHFL¿FPDVWHUVWDWLRQRUJURXSRIPDVWHUVWDWLRQV
7KH5<,3LQSXWVFDQKDYHGLIIHUHQWFDOOLQJUXOHVWKDQWKHGHIDXOWFDOOLQJUXOHVHWGXULQJWKH,;6HULHVSURJUDPPLQJ
6HOHFWWKHFDOOLQSULRULW\OHYHOIRUHDFKLQSXWXVLQJWKHPriority drop down menu.
Enter the target IP address of the station for remote call-in.
Click Apply SettingsWRVDYHWKHFKDQJHV'RQRWUHERRWWKHDGDSWRUDWWKLVWLPH
Click APPLICATION SETUPWRUHWXUQWRWKH$SSOLFDWLRQ&RQ¿JXUDWLRQ6FUHHQ
Click on DestinationsQH[WWRWKHLQSXWEHLQJFRQ¿JXUHG$QRWKHUZLQGRZZLOORSHQ(QWHUWKHVWDWLRQQXPEHURIWKH
master stations to be called when the input is triggered.
When the target IP address is a door station, a maximum of 20 master stations can be entered.
When the target IP address is a master station, a maximum of 20 master stations or 1 group can be entered. A group can
consist of up to 50 master stations and must be created using the IX Support Tool.
Check the Enable box beside each station entered.
Click on Apply Settings then click Reboot to restart the adaptor with the changes.
IS-IP Series: Relay Output Programming
7KH5<,3KDVUHOD\VWKDWFDQEHSURJUDPPHGWRWULJJHUZKHQDVSHFL¿FGRRUVWDWLRQLVFDOOLQJZKLOHLQ
communication, or while calling and communicating. The relays can also be programmed for door release from one or
multiple IP master station(s).
Set the RY-IP44 for use with the IS-IP Series (refer to page 5).
From the 'HYLFH&RQ¿JXUDWLRQ screen, click APPLICATION SETUP.
Application Setup button
IS-IP Series: Relay Output Programming FRQW
Linked Stations Table:
(QWHUWKH,3DGGUHVVDQG7HUP,'IRUHDFK,6,3VWDWLRQLQWKH,6FRQ¿JXUDWLRQ7KLVWDEOHLVXVHGDVDUHIHUHQFHIRU
HDFK7HUP,'LQWKHV\VWHP$IWHULQSXWWLQJHDFK,3DGGUHVVDQG7HUP,'FOLFNApply Settings at the bottom of the
SDJHWRVDYHWKHVHWWLQJVWRPHPRU\5HWXUQWRWKH$SSOLFDWLRQ6FUHHQRUUHERRWDGDSWRUE\FOLFNLQJWKHReboot button.
Rebooting must occur to update adaptor settings.
'H¿QLWLRQ TermID
$7HUP,'LGHQWL¿HVWKHORFDWLRQRIDQ,6,3VWDWLRQLQWKH,66HULHVFRQ¿JXUDWLRQ,WDOVRGLVWLQJXLVKHVEHWZHHQPDVWHU
VWDWLRQVDQGGRRUVWDWLRQV$PDVWHUVWDWLRQ7HUP,'ZLOOEH[[DQGDGRRUVWDWLRQ7HUP,'ZLOOEH[[³[[´
UHSUHVHQWVWKHOLQHLQZKLFKWKHVWDWLRQUHVLGHVXQGHU³,38QLW5HJLVWUDWLRQ´LQWKH,6+RVWSURJUDPPLQJ
Example:
'RRUVWDWLRQLQDGGUHVVORFDWLRQ
0DVWHUVWDWLRQLQDGGUHVVORFDWLRQ
Relay Functionality:
(QWHUWKH7HUP,'IRUWKHGRRUVWDWLRQWREHDVVRFLDWHGWRWKHUHOD\
Select the relay action from the drop down menu.
Relay Action options:
•
•
•
•
•
'RRU5HOHDVH1RUPDOO\2SHQ
5HOD\ZLOOWULJJHUZKHQDFRQ¿JXUHGPDVWHUVWDWLRQSXVKHVWKHGRRUUHOHDVHEXWWRQ
for the associated door.
'RRU5HOHDVH1RUPDOO\&ORVHG
$FWLYHZKLOH&DOOLQJIURPVRXUFH
Relay will trigger when the associated door station calls or communicates.
$FWLYHZKLOHLQ&RPPXQLFDWLRQZLWKVRXUFH
$FWLYHGXULQJ&DOOLQJDQG&RPPXQLFDWLRQ
_5<,33URJUDPPLQJ0DQXDO
}
}
:KHQWKHUHOD\DFWLRQLVVHWIRUWKH³'RRU5HOHDVH´RSWLRQVWKHUHOD\ZLOOWULJJHUZKHQWKHDVVRFLDWHGGRRUVWDWLRQLVLQ
FRPPXQLFDWLRQEXWRQO\ZKHQD³FRQ¿JXUHG´PDVWHUVWDWLRQSXVKHVWKHGRRUUHOHDVHEXWWRQ
:KHQWKHUHOD\DFWLRQLVVHWIRUDQ\RIWKH³$FWLYH:KLOH´RSWLRQVWKHUHOD\ZLOOWULJJHUZKHQWKHDVVRFLDWHGGRRUVWDWLRQ
FDOOVRUFRPPXQLFDWHVDWDQ\SULRULW\OHYHO
$IWHUWKH'RRU7HUP,'DQG5HOD\$FWLRQKDVEHHQVHWFOLFNApply SettingsDWWKHERWWRPRIWKHVFUHHQWRVDYHWKH
settings to memory. Return to the Application Screen or reboot adaptor by clicking on the Reboot button. Rebooting
must occur to update adaptor settings.
To program a master station to control door release, click on the &RQ¿JXUH button. A new window will open and the
WDEOHVKRZQEHORZZLOOEHSRSXODWHGEDVHGRQWKHHQWULHVPDGHLQWKH/LQNHG6WDWLRQV7DEOHVHHSDJH&KHFN
the FlagER[EHVLGHHDFKPDVWHUVWDWLRQWKDWZLOOEH³DOORZHG´WRWULJJHUWKLVUHOD\IRUGRRUUHOHDVH2QFHDOOPDVWHU
VWDWLRQVKDYHEHHQFKHFNHGFOLFNApply SettingsDWWKHERWWRPRIWKLVZLQGRZWRVDYHWKHVHWWLQJVWRPHPRU\
Reboot to update adaptor settings.
Note: 7KH,662)7VRIWZDUHPDVWHUVVWDWLRQVFDQ127EHHQDEOHGIRUGRRUUHOHDVHXVLQJWKH5<,3
IS-IP Series: Input Programming
7KH5<,3DGDSWRUKDVLQSXWVWKDWFDQEHSURJUDPPHGWRWULJJHUDFDOOLQIURPDVSHFL¿FGRRUVWDWLRQWRDVSHFL¿F
PDVWHUVWDWLRQRUJURXSRIPDVWHUVWDWLRQVPD[7KH5<,3LQSXWVFDQKDYHGLIIHUHQWFDOOLQJUXOHVWKDQWKHGHIDXOW
FDOOLQJUXOHVHWXQGHU$GYDQFHG6WDWLRQ6HWWLQJVLQWKH,6+RVW3URJUDPPLQJ
&KRRVHWKH&DOO,QSULRULW\OHYHOIRUHDFKLQSXWXVLQJWKHPriority drop down menu. Enter the target IP address of the
door station for remote call-in.
Click Apply SettingsWRVDYHWKHFKDQJHV'RQRWUHERRWWKHDGDSWRUDWWKLVWLPH
Click APPLICATION SETUPWRUHWXUQWRWKH$SSOLFDWLRQ&RQ¿JXUDWLRQVFUHHQ
IS-IP Series: Input Programming FRQW
Click on DestinationsQH[WWRWKHLQSXWEHLQJFRQ¿JXUHG$QHZZLQGRZZLOORSHQ(QWHUWKH7HUP,'IRUHDFKPDVWHU
VWDWLRQWREHFDOOHGVHHSDJHIRU7HUP,'LQIRUPDWLRQ$PD[LPXPRIPDVWHUVWDWLRQV7HUP,'¶VFDQEHHQWHUHG
Check the EnableER[EHVLGHHDFK7HUP,'HQWHUHGWRDOORZWKHPDVWHUWREHFDOOHG2QFHDOOPDVWHUVWDWLRQ7HUP,'¶V
KDYHEHHQHQWHUHGDQGHQDEOHGFOLFNApply SettingsDWWKHERWWRPRIWKLVZLQGRZWRVDYHWKHVHWWLQJVWRPHPRU\
Reboot to update adaptor settings.
IPW-1A: Relay Output Programming
The RY-IP44 has 4 relays that can be programmed to trigger while calling, while in communication, or while calling and
FRPPXQLFDWLQJZLWKDVSHFL¿FGRRUVWDWLRQ7KHUHOD\VFDQDOVREHSURJUDPPHGIRUGRRUUHOHDVH
Set the RY-IP44 for use with the IPW-1A (refer to page 5).
Relay Action options:
• 'RRU5HOHDVH1RUPDOO\2SHQ
*Relay will trigger when the PC master station pushes the door release button.
• 'RRU5HOHDVH1RUPDOO\&ORVHG
• $FWLYHZKLOH&DOOLQJIURPVRXUFH
• $FWLYHZKLOHLQ&RPPXQLFDWLRQZLWKVRXUFH
Relay will trigger when the associated door station calls or communicates.
• $FWLYHGXULQJ&DOOLQJDQG&RPPXQLFDWLRQ
• AFWLYH:KLOH$Q\6WDWLRQ&DOOLQJ } Relay triggers when any station calls. No assignment required.
}
}
* When using the RY-IP44 for door release, the relay on the IPW-1A must be set to door release and the relay
PXVWEHMXPSHUHGWRWKHVHQVRULQSXWDVVKRZQEHORZ
IN0 IN1
NO
C
NC
From the 'HYLFH&RQ¿JXUDWLRQ screen, click APPLICATION SETUP.
Application Setup button
10 | RY-IP44 Programming Manual
(QWHUWKH6WDWLRQ,'IRUWKH,3:$WREHDVVRFLDWHGZLWKHDFKUHOD\RQWKH5<,36HOHFWWKHUHOD\FRQGLWLRQIURPWKH
Relay Action drop down menu. When done, click on Apply Settings. Click Reboot on the next screen to restart the
adaptor with the applied settings.
IX Mobile Server
7KH5<,3DGDSWRULVXVHGDVDVHUYHUIRUXSWRPRELOHGHYLFHVZKHQXVLQJ,;0RELOH
Set the RY-IP44 for use with the IX Series (refer to page 5).
(QWHUWKH,3DGGUHVVIRUHDFKRIWKHPRELOHGHYLFHVLQWKHIX Mobile Server Functionality table.
Click on Apply Settings then click Reboot to restart the adaptor with the changes.
5HIHUWRSDJHVIRUVWHSVRQDGGLQJDPRELOHGHYLFHWRWKH,;V\VWHPXVLQJWKH,;6XSSRUW7RRODQGIRUVHWWLQJ
XSWKHPRELOHGHYLFH
IX-Mobile
The IX Mobile app turns an iPhone®, iPad®, or iPod touch® running Apple®L26YHUVLRQVRUKLJKHURUPRELOH
GHYLFHVUXQQLQJ$QGURLGŒRUKLJKHULQWRDQ,;6HULHVVXEPDVWHUVWDWLRQ)ROORZWKHVWHSVEHORZWRFRQ¿JXUHWKH
,;6HULHVV\VWHPDQGWRSUHSDUHWKHPRELOHGHYLFHVIRUFRQQHFWLRQYLD:L)LRURYHUDFHOOXODUQHWZRUNZLWKD931
FRQQHFWLRQ3OHDVHQRWHWKHPRELOHGHYLFHUXQQLQJWKH,;0RELOHDSSDQGWKH,;6HULHVV\VWHPPXVWEHFRQQHFWHGWR
the same network.
Important:
- An IX-MV master station and an RY-IP44 adaptor are required in the system for the IX Mobile App to work - The IX Series hardware devices must be programmed and operational prior to adding the IX Mobile device -
11
Adding a Mobile Device to the IX Support Tool
• Open the IX Support Tool and log in to the system being programmed.
Expand the 1 Station Information tree and click on 2 ,GHQWL¿FDWLRQ.
2QWKHQH[WDYDLODEOHOLQH assign a Number*, Name*, and select Master Station as the Type for the mobile app.
5HSHDWVWHSVIRUHDFKLQVWDQFHRI,;0RELOHDSSWKDWQHHGVWREHDGGHGWRWKHV\VWHP
Note Station Information here to refer to later
Number
Name
.
.
.
.
.
.
.
.
1
2
Click the
EXWWRQWRVDYHFKDQJHV
*
IP Address
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
For Programmers/Installers:
We recommend writing the station Number,
Name, and IP Address into this table for
reference when setting up the IX Mobile app.
• Expand the 4 Network Settings tree and click on 5 IP Address.
7KH,3$GGUHVVRIWKHDGGHGGHYLFHVZLOOEHEODQN(QWHUDQ 6 IP Address* and Subnet Mask
ZLWKLQWKHVDPHUDQJHDVWKHRWKHUGHYLFHVLQWKHV\VWHP
4
5
6
Click the
EXWWRQWRVDYHFKDQJHV
• Expand the Function Settings tree and click on Door Release Settings.
Click the Individual Master Station Door Release Settings button.
10 Select the newly added mobile master from the drop down. Click
this selected master station, click the 12 Apply button.
11
Select. To enable door release for all stations for
10
11
12
12 | RY-IP44 Programming Manual
• $SRSXSZLOODSSHDUVD\LQJ³$OOVWDWLRQVZLOOEHVHWIRUGRRUUHOHDVH&RQWLQXH"´&OLFN OK. Another pop-up will
DSSHDUVD\LQJ³'RRUUHOHDVHVHWWLQJVFRPSOHWH´&OLFN 14 OK.
14
Repeat the process for each mobile master station added to the system.
EXWWRQWRVDYHFKDQJHV
Click the
• Click 15 File, then 16 Upload Settings To Station.
Select the hardware stations from the list and click
Start Upload. Click
OK on the pop-up to upload the settings.
15
16
9HULI\VXFFHVVRUIDLOXUHRIXSORDGWRHDFKGHYLFHLQWKH6WDWXVFROXPQ
&RQ¿JXUDWLRQ)LOH
7KH,;6XSSRUW7RROFUHDWHVDFRQ¿JXUDWLRQ¿OHIRUHDFKGHYLFHLQWKHV\VWHPDQGVDYHVLWWRDIROGHUZLWKLQWKH
6XSSRUW7RROSURJUDPIROGHU2QFHDOOSURJUDPPLQJFKDQJHVKDYHEHHQPDGHDQGXSORDGHGWKHFRQ¿JXUDWLRQ¿OH
ZLOOQHHGWREHFRSLHGWRWKHPRELOHGHYLFH
• 7KHIROGHUFRQWDLQLQJWKHFRQ¿JXUDWLRQ¿OHPD\EHKLGGHQ7RVKRZKLGGHQIROGHUVRSHQ:LQGRZV([SORUHUDQG
click 1 Organize. Click 2 Folder and search options. Select the View tab and select the radio button beside
4 6KRZKLGGHQÀOHVIROGHUVDQGGULYHV then click 5 OK.
1
2
4
5
• 1DYLJDWHWR³&?3URJUDP)LOHV[?6XSSRUW7RRO?6\VWHP'DWD?QDPHRIV\VWHP?6HWWLQJ´DQGVHOHFWWKH
FRQ¿JXUDWLRQ¿OHWKDWLVDVVRFLDWHGZLWKWKHPRELOHGHYLFH,WZLOOEHLGHQWL¿HGE\WKH6WDWLRQ1XPEHUWKDWZDV
DVVLJQHGWRLWLQWKH,;6XSSRUW7RRO&RS\WKHFRQ¿JXUDWLRQ¿OHWRDORFDWLRQRQWKHSURJUDPPLQJ3&WKDWFDQHDVLO\
EHWUDQVIHUUHGWRWKHPRELOHGHYLFH
1RWH,IXVLQJDELWRSHUDWLQJV\VWHPQDYLJDWHWR&?3URJUDP)LOHV?6XSSRUW7RRO?6\VWHP'DWD?QDPHRIV\VWHP?6HWWLQJ
App Installation and Setup for Apple
$SS6WRUHLVDVHUYLFHPDUNRI$SSOH,QF
'RZQORDG,;0RELOHIURPWKHApp StoreSM
1 Connect to the WiFi network associated with the IX Series
1
system installation. Once connected, tap on the connected network.
2 Tap Static and enter the ,3$GGUHVV that was assigned when
2
&RQQHFWWKHPRELOHGHYLFHWRWKH3&WKDWKDVL7XQHVLQVWDOOHG
FRQ¿JXULQJWKHDSSZLWKWKH,;6XSSRUW7RRO.
Open iTunes and click Apps. Scroll down to File Sharing and
select IX Mobile. Click Add FileDQGQDYLJDWHWRZKHUHWKH
FRQ¿JXUDWLRQ¿OHLVVDYHG6HOHFWWKH¿OHDQGFOLFNOpen.
4 /DXQFKWKHDSSOLFDWLRQRQWKHPRELOHGHYLFH
Tap the
4
Menu icon.
5 Tap Setup.
(QWHUWKH$GPLQ,'DQG3DVVZRUGDQGWDSOK.
5
'HIDXOW,'DGPLQ
'HIDXOW3DVVZRUGDGPLQ
6 Tap App Server. Enter the IP Address and Port Number for
6
WKH$SS6HUYHU5<,35HIHUWRSDJHIRULQIRUPDWLRQRQ
VHWWLQJXSWKH$SS6HUYHU
Tap Import from File.
6HOHFWWKHFRQ¿JXUDWLRQ¿OHWKDWZDVWUDQVIHUUHGWRWKLVGHYLFH
LQ6WHS7DSOK.
$SRSXSZLOODSSHDUVWDWLQJ³1HZFRQ¿JXUDWLRQDSSOLHG´
7RXQORFNWKHDSSFDOOWKHPRELOHGHYLFHIURPDPDVWHUVWDWLRQ
in the system.
$SSOHWKH$SSOHORJRL3KRQHL3DGL3RGWRXFKDQGL7XQHVDUHWUDGHPDUNVRI$SSOH,QFUHJLVWHUHGLQWKH86DQGRWKHUFRXQWULHV7KH$SS6WRUH
LVDVHUYLFHPDUNRI$SSOH,QF
14 | RY-IP44 Programming Manual
App Installation and Setup for Android
'RZQORDG,;0RELOHXVLQJGoogle PlayTM
1 Connect to the WiFi network associated with the IX Series
1
system installation. Once connected, tap and hold on the
connected network.
2 A pop-up will appear. Tap 0RGLI\QHWZRUNFRQ¿J.
2
Check the box beside Show advanced options.
4 8QGHUIP settings, select Static and enter the ,3$GGUHVV that
4
ZDVDVVLJQHGZKHQFRQ¿JXULQJWKHDSSZLWKWKH,;6XSSRUW
Tool. Once entered, tap Save.
5 &RQQHFWWKHPRELOHGHYLFHWRWKH3&XVHGIRUSURJUDPPLQJWKH
5
V\VWHP8VLQJWKH3&QDYLJDWHWRWKHPRELOHGHYLFHDQGORFDWH
the ixapp_settingsIROGHU3DVWHWUDQVIHUWKHFRQ¿JXUDWLRQ¿OH
VDYHGIURPWKH,;6XSSRUW7RROWRWKLVIROGHU
6 /DXQFKWKHDSSOLFDWLRQRQWKHPRELOHGHYLFH
Tap the
6
Menu icon, then tap Settings.
Tap Setup.
(QWHUWKH$GPLQ,'DQG3DVVZRUGDQGWDSOK.
'HIDXOW,'DGPLQ
'HIDXOW3DVVZRUGDGPLQ
Tap App Server. Enter the IP Address and Port Number for
WKH$SS6HUYHU5<,35HIHUWRSDJHIRULQIRUPDWLRQRQ
VHWWLQJXSWKH$SS6HUYHU
Tap Import from File.
6HOHFWWKHFRQ¿JXUDWLRQ¿OHWKDWZDVWUDQVIHUUHGWRWKLVGHYLFH
in Step 5. Tap OK.
10
$SRSXSZLOODSSHDUVWDWLQJ³6HUYLFHVWDUWHGZLWKDQHZFRQ¿J´
11
7RXQORFNWKHDSSFDOOWKHPRELOHGHYLFHIURPDPDVWHUVWDWLRQ
in the system.
10
Android, Google Play, and the Google Play logo are trademarks of Google Inc.
15
RY-IP44 Dimensions
Mounting:
´
'HSWK
´
The RY-IP44 adaptor mounts to an Aiphone
:',1PRXQWLQJUDLOVROGVHSDUDWHO\
´
RY-IP44 Wiring
PT
= 3RZHU7UDQVIRUPHUXVHSURSHUSRZHUIRUWKHVWULNHPDJORFNRUH[WHUQDOVLJQDOLQJGHYLFHEHLQJXVHG
5HOD\FRQWDFWUDWLQJ9'&$
Door release:
External signaling:
Relay 1
R1
{ NO
Relay 1
R1
{ NO
Relay 2
R2
{ NO
Relay 2
R2
{ NO
5HOD\
{
5
NO
5HOD\
5
{ NO
Relay 4
R4
{ NO
Relay 4
R4
{ NO
'RRU
Strike
PT
Bell
PT
Inputs:
Power:
Connect a normally open (N/O) contact across any
input and ground.
8VHD9'&P$#9'&SRZHUVXSSO\WR
power the RY-IP44 adaptor. 8VHWKH$LSKRQH
368/SRZHUVXSSO\VROGVHSDUDWHO\
I1
I2
,
I4
Input 1
Input 2
,QSXW
Input 4
Ground
{
G
G
368/
Power
{
+
-
+
-
FCC WARNING:
7KLVGHYLFHFRPSOLHVZLWK3DUWRIWKH)&&UXOHV
2SHUDWLRQLVVXEMHFWWRWKHIROORZLQJWZRFRQGLWLRQV
7KLVGHYLFHPD\QRWFDXVHKDUPIXOLQWHUIHUHQFH
7KLVGHYLFHPXVWDFFHSWDQ\LQWHUIHUHQFHWKDWPD\FDXVHXQGHVLUHGRSHUDWLRQ
•
For proper regulatory compliance, the drain wire should be disconnected at the power supply end of the cable.
•
&KDQJHVRUPRGL¿FDWLRQVQRWH[SUHVVO\DSSURYHGE\WKHSDUW\UHVSRQVLEOHIRUFRPSOLDQFHFRXOGYRLGWKHXVHU¶V
authority to operate the equipment.
Aiphone Corporation
0416 #95101
16 | RY-IP44 Programming Manual
www.aiphone.com
tech@aiphone.com
Download