Dimmable LED 6 inch Recessed Downlight Retrofit

advertisement
Dimmable LED 6 inch Recessed Downlight Retrofit
Recipe for Quality Light
Energy-efficient LED recessed retrofit downlight offers uniform light
distribution as well as single bin color consistency. Ideal for 65W
BR40 incandescent lamp replacement and consuming less than
14W, DL6 LED recessed retrofit enables 50-75% energy savings
and more than 50,000 hour maintenance free operation.
Features & Benefits
• Meets and exceeds Energy Star specifications
• Meets California Title 24 Efficacy Requirement
• Uniform color distribution
• Guaranteed single bin color consistency with enhanced
illumination uniformity
• Reduced glare
• Chip-array on ceramic LED Technology
• Fits most 6” recessed cans available in the market
• 3 year warranty- DL6 and power supply
Operating Temperature Range: -20ºC ~ +50ºC / -4ºF ~ +122ºF
Storage Temperature Rang: -20ºC ~ +90ºC / -4ºF ~ +194ºF
Ordering Information
Model
Number
Wattage
(W)
Input Voltage
(VAC)
Average Rated
Life (hrs)
Delivered
Lumens (lm)
CBCP
(cd)
CRI
Power
Factor
DL6
13.7
110/120
50,000
600
320
>80
>0.92
MegaLight Inc. | 581 Boston Mills Rd., Suite 500 | Hudson, OH 44236 | 800-957-1797 | P. 330-650-0008 | F. 330-650-0222 | www.megalight.com
Photometry
Zonal Lumen Summary
Candela Distribution
Angle Candela
0
320
5
319
10
321
15
316
20
305
25
286
30
262
35
235
40
203
45
168
50
130
55
86
60
36
65
5
70
3
75
2
80
0
85
0
90
0
Zone
Lumens % Luminaire
0 - 30
251
40.89
0 - 40
397
64.65
0 - 60
601
97.92
0 - 90
614 100.00
40 - 90
217
35.35
60 - 90
13
2.08
90 - 180
0
0
0 - 180
614 100.00
Illuminance Cone Diagram
Distance from
Workplane
Footcandles
Beam Diameter
4’
20
8’
6’
9
12.1’
8’
5
16.1’
10’
3
20.2’
12’
2
24.2’
Mechanical Information
Accessories (included):
Edison Connector
4.94 inch
125.60mm
7.283 inch
185.0mm
MegaLight Inc. | 581 Boston Mills Rd., Suite 500 | Hudson, OH 44236 | 800-957-1797 | P. 330-650-0008 | F. 330-650-0222 | www.megalight.com
Safety Information
ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION.
TO AVOID ELECTRICAL SHOCK OR COMPONENTS DAMAGE, DISCONNECT POWER BEFORE ATTEMPTING
INSTALLATION OF THE POWER SUPPLIES AND/OR MODULES.
Failure to install the LED lighting source in accordance with the National Electrical Code (NEC), all applicable Federal,
State and local electric codes as well as the specific Underwriters Laboratory (UL) safety standards for the installation,
location and application may cause serious personal injury, death, property damage and/or product malfunction.
Avoid looking directly into light beam as the high brightness beam may damage the eyes.
Installation Instructions/Application Notes
• Power to unit should be off before attempting retrofit installation of this LED lighting source. All applicable
electrical and safety standards must be observed. Any concerns should be addressed by qualified individuals
• Use standard ESD precautions during handling and installation of this lighting source.
• The LED lighting source is not water proof. For high humidity use, this lighting source must be used in a fixture
with IP65 rating.
Compatible Dimmers:
Cooper, Aspire Series (Part numbers 9530XXX)
Leviton, Illumitech Series (Part numbers IPI06-XXX)
Leviton, Trimatron Series (Part numbers 6602-X, 6681-X,
6683-X, 6684-X, 700-X and 705-X)
Leviton, SureSlide Series (Part Numbers 6631)
Leviton, True Touch Series (Part Number 6606-1LM)
Lutron Skylark Series (Part Number S-600, S2-LH)
Lutron, Maestro Series (Part Numbers MAW-600)
Lutron Nova T Series (Part number NTELV-600)
Lutron Faedra (Part Number FAELV-500-XX)
Leviton Acenti (Part Number ACE06-XXX)
Leviton Vizia (Part Number VZE04)
MegaLight Inc. | 581 Boston Mills Rd., Suite 500 | Hudson, OH 44236 | 800-957-1797 | P. 330-650-0008 | F. 330-650-0222 | www.megalight.com