Technical Data Sheet – Unshielded (YY) PVC Control

 

         Technical   Data   Sheet   –   Unshielded   (YY)   PVC   Control   Cable  

 

 

 

 

 

 

MachineTuff   Cables   

 

Applications  

 

Designed   for   applications   which   are   installed   in   occasional   flexing   and   fixed   locations.

  Cable   applications   include   precision   control   sensors,   multi   axis   control   machines,   temperature   controllers,   control   panels,   machine   cutting   tools,   auxiliary   equipment,   motor   speed   control,   production   machinery   and   many   more.

 

 

 

 

 

General   Reference   Standards    

DIN   VDE   0295,   IEC   60228,   BS6360  

DIN   EN   50290 ‐ 2 ‐ 22,   DIN   VDE   0207 ‐ 363 ‐ 4 ‐ 1  

DIN   VDE   0482 ‐ 332 ‐ 1 ‐ 2,   DIN   EN   60332 ‐ 1 ‐ 2,   IEC   60332 ‐ 1 ‐ 2  

RoHS   Directives  

 

 

Construction   &   Performance  

1.

  Conductor   Material   Stranded   bare   copper   (DIN   VDE   0295   Class   5)  

     

2.

  Insulation   Material   &   Colour  

   

3.

  Jacket   /   Sheath   Material  

   

4.

  Flame   Retardancy  

   

5.

  Voltage   Rating   (Uo/U)  

   

6.

  Oil   Resistant  

   

7.

  Temperature   Range  

   

8.

  Bending   Radius  

   

9.

  Other   Properties  

PVC   (polyvinyl    chloride),   DIN   VDE   0293 ‐ 1   (colour)  

A)   All   black   colour   with   number   coding   =   without   protective   conductor.

 

B)   Black   color   colour   with   number   coding   plus   1   green   &   yellow   =   with   protective   conductor.

 

 

 

PVC   (polyvinyl    chloride)  

 

VDE   0482 ‐ 332 ‐ 1 ‐ 2,   DIN   EN   60332 ‐ 1 ‐ 2,   IEC   60332 ‐ 1 ‐ 2  

 

300   /   500   V  

 

DIN   EN   50290 ‐ 2 ‐ 22   (TM54)  

‐ 30°C   TO   +70°C   (Occasional   movement)  

 

‐ 40°C   TO   +80°C   (Fixed   installation)  

10   x   OD   (Occasional   movement)  

4   x   OD   (Fixed   installation)  

 

Good   UV   resistance,   chemical   resistance   &   flexibility  

©   2014   Belden,   Inc  

All   Rights   Reserved.

 

Although   Belden   makes   every   reasonable   effort   to   ensure   their   accuracy   at   the   time   of   this   publication,   information   and   specifications   described   herein   are   subject   to   error   or   omission   and   to   change   without   notice,   and   the   listing   of   such   information   and   specifications   does   not   ensure   product   availability.

  Belden   provides   the   information   and   specifications   herein   on   an   "AS   IS"   basis,   with   no   representations   or   warranties,   whether   express,   statutory   or   implied.

  In   no   event   will   Belden   be   liable   for   any   damages  

(including   consequential,   indirect,   incidental,   special,   punitive,   or   exemplary   damages)   whatsoever,   even   if   Belden   has   been   advised   of   the   possibility   of   such   damages,   whether   in   an   action   under   contract,   negligence   or   any   other   theory,   arising   out   of   or   in   connection   with   the   use,   or   inability   to   use,   the   information   or   specifications   described   herein.

  All   sales   of   Belden   products   are   subject   to   Belden's   standard   terms   and   conditions   of   sale.

 

1

 

 

   

Part   Code  

3G0.75

 

4X0.75

 

4G0.75

 

5X0.75

 

5G0.75

 

7X0.75

 

7G0.75

 

9X0.75

 

9G0.75

 

10X0.75

 

10G0.75

 

12X0.75

 

12G0.75

 

14X0.5

 

14G0.5

 

16X0.5

 

16G0.5

 

18X0.5

 

18G0.5

 

20X0.5

 

20G0.5

 

2X0.75

 

3X0.75

 

2X0.5

 

3X0.5

 

3G0.5

 

4X0.5

 

4G0.5

 

5X0.5

 

5G0.5

 

7X0.5

 

7G0.5

 

9X0.5

 

9G0.5

 

10X0.5

 

10G0.5

 

12X0.5

 

12G0.5

 

14X0.75

 

14G0.75

 

16X0.75

 

16G0.75

 

18X0.75

 

18G0.75

 

20X0.75

 

20G0.75

 

 

       Technical   Data   Sheet   –   Unshielded   (YY)   PVC   Control   Cable  

 

3   G0.75

 

4   X0.75

 

4   G0.75

 

5   X0.75

 

5   G0.75

 

7   X0.75

 

7   G0.75

 

9   X0.75

 

9   G0.75

 

10   X0.75

 

10   G0.75

 

12   X0.75

 

12   G0.75

 

14   X0.75

 

14   G0.75

 

16   X0.75

 

16   G0.75

 

18   X0.75

 

18   G0.75

 

20   X0.75

 

20   G0.75

 

Cable  

Description  

2   X0.5

 

3   X0.5

 

3   G0.5

 

4   X0.5

 

4   G0.5

 

5   X0.5

 

5   G0.5

 

7   X0.5

 

7   G0.5

 

9   X0.5

 

9   G0.5

 

10   X0.5

 

10   G0.5

 

12   X0.5

 

12   G0.5

 

14   X0.5

 

14   G0.5

 

16   X0.5

 

16   G0.5

 

18   X0.5

 

18   G0.5

 

20   X0.5

 

20   G0.5

 

2   X0.75

 

3   X0.75

 

  TABLE   A  

0.75

 

0.75

 

0.75

 

0.75

 

0.75

 

0.75

 

0.75

 

0.75

 

0.75

 

0.75

 

0.75

 

0.75

 

0.75

 

0.75

 

0.75

 

0.75

 

0.75

 

0.5

 

0.5

 

0.75

 

0.75

 

Nom.

  Conductor  

Size   (mm²)  

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.5

 

0.75

 

0.75

 

 

14  

14  

16  

16  

18  

18  

20  

20  

5  

7  

7  

9  

9  

3  

4  

4  

5  

10  

10  

12  

12  

9  

10  

10  

12  

12  

5  

7  

7  

9  

No.

  Of  

Cores  

2  

3  

3  

4  

4  

5  

18  

18  

20  

20  

2  

3  

14  

14  

16  

16  

 

10.70

 

10.70

 

11.30

 

11.30

 

12.00

 

12.00

 

12.70

 

12.70

 

5.60

 

6.20

 

6.20

 

6.80

 

6.80

 

7.50

 

7.50

 

9.30

 

9.30

 

9.80

 

9.80

 

10.10

 

10.10

 

Nom.

  Cable  

Diameter   (mm)  

4.80

 

5.10

 

5.10

 

5.60

 

5.60

 

6.20

 

6.20

 

6.80

 

6.80

 

8.40

 

8.40

 

8.80

 

8.80

 

9.10

 

9.10

 

9.60

 

9.60

 

10.20

 

10.20

 

10.80

 

10.80

 

11.40

 

11.40

 

5.30

 

5.60

 

 

187  

187  

213  

213  

241  

241  

269  

269  

48  

61  

61  

75  

75  

96  

96  

128  

128  

142  

142  

163  

163  

Nom.

  Cable   Weight  

(kg/km)  

  30  

37  

37  

47  

47  

57  

57  

73  

73  

97  

97  

107  

107  

122  

122  

139  

139  

159  

159  

179  

179  

199  

199  

38  

48  

©   2014   Belden,   Inc  

All   Rights   Reserved.

 

Although   Belden   makes   every   reasonable   effort   to   ensure   their   accuracy   at   the   time   of   this   publication,   information   and   specifications   described   herein   are   subject   to   error   or   omission   and   to   change   without   notice,   and   the   listing   of   such   information   and   specifications   does   not   ensure   product   availability.

  Belden   provides   the   information   and   specifications   herein   on   an   "AS   IS"   basis,   with   no   representations   or   warranties,   whether   express,   statutory   or   implied.

  In   no   event   will   Belden   be   liable   for   any   damages  

(including   consequential,   indirect,   incidental,   special,   punitive,   or   exemplary   damages)   whatsoever,   even   if   Belden   has   been   advised   of   the   possibility   of   such   damages,   whether   in   an   action   under   contract,   negligence   or   any   other   theory,   arising   out   of   or   in   connection   with   the   use,   or   inability   to   use,   the   information   or   specifications   described   herein.

  All   sales   of   Belden   products   are   subject   to   Belden's   standard   terms   and   conditions   of   sale.

 

2

 

         Technical   Data   Sheet   –   Unshielded   (YY)   PVC   Control   Cable  

2   X1.5

 

3   X1.5

 

3   G1.5

 

4   X1.5

 

4   G1.5

 

5   X1.5

 

5   G1.5

 

7   X1.5

 

7   G1.5

 

12   G1.0

 

14   X1.0

 

14   G1.0

 

16   X1.0

 

16   G1.0

 

18   X1.0

 

18   G1.0

 

20   X1.0

 

20   G1.0

 

Cable  

Description  

2   X1.0

 

3   X1.0

 

3   G1.0

 

4   X1.0

 

4   G1.0

 

5   X1.0

 

5   G1.0

 

7   X1.0

 

7   G1.0

 

9   X1.0

 

9   G1.0

 

10   X1.0

 

10   G1.0

 

12   X1.0

 

9   X1.5

 

9   G1.5

 

10   X1.5

 

10   G1.5

 

12   X1.5

 

12   G1.5

 

14   X1.5

 

14   G1.5

 

16   X1.5

 

16   G1.5

 

18   X1.5

 

18   G1.5

 

20   X1.5

 

20   G1.5

 

2   X2.5

 

2  

3  

3  

4  

4  

5  

5  

7  

7  

12  

14  

14  

16  

16  

18  

18  

20  

20  

5  

5  

7  

7  

9  

9  

10  

10  

12  

No.

  Of  

Cores  

2  

3  

3  

4  

4  

9  

9  

10  

10  

12  

12  

14  

14  

16  

16  

18  

18  

20  

20  

2  

Part   Code  

9X1.5

 

9G1.5

 

10X1.5

 

10G1.5

 

12X1.5

 

12G1.5

 

14X1.5

 

14G1.5

 

16X1.5

 

2X1.5

 

3X1.5

 

3G1.5

 

4X1.5

 

4G1.5

 

5X1.5

 

5G1.5

 

7X1.5

 

7G1.5

 

16G1.5

 

18X1.5

 

18G1.5

 

20X1.5

 

20G1.5

 

2X2.5

 

9G1.0

 

10X1.0

 

10G1.0

 

12X1.0

 

12G1.0

 

14X1.0

 

14G1.0

 

16X1.0

 

16G1.0

 

18X1.0

 

18G1.0

 

20X1.0

 

20G1.0

 

2X1.0

 

3X1.0

 

3G1.0

 

4X1.0

 

4G1.0

 

5X1.0

 

5G1.0

 

7X1.0

 

7G1.0

 

9X1.0

 

1.5

 

1.5

 

1.5

 

1.5

 

1.5

 

1.5

 

1.5

 

1.5

 

1.5

 

1.0

 

1.0

 

1.0

 

1.0

 

1.0

 

1.0

 

1.0

 

1.0

 

1.0

 

Nom.

  Conductor  

Size   (mm²)  

1.0

 

1.0

 

1.0

 

1.0

 

1.0

 

1.0

 

1.0

 

1.0

 

1.0

 

1.0

 

1.0

 

1.0

 

1.0

 

1.0

 

1.5

 

1.5

 

1.5

 

1.5

 

1.5

 

1.5

 

1.5

 

1.5

 

1.5

 

1.5

 

1.5

 

1.5

 

1.5

 

1.5

 

2.5

 

6.20

 

6.60

 

6.60

 

7.30

 

7.30

 

8.10

 

8.10

 

8.90

 

8.90

 

10.90

 

11.50

 

11.50

 

12.30

 

12.30

 

13.00

 

13.00

 

13.80

 

13.80

 

Nom.

  Cable  

Diameter   (mm)  

5.70

 

6.10

 

6.10

 

6.70

 

6.70

 

7.40

 

7.40

 

8.10

 

8.10

 

10.10

 

10.10

 

10.50

 

10.50

 

10.90

 

11.10

 

11.10

 

11.60

 

11.60

 

12.00

 

12.00

 

12.70

 

12.70

 

13.50

 

13.50

 

14.30

 

14.30

 

15.20

 

15.20

 

7.8

 

57  

74  

74  

94  

94  

117  

117  

151  

151  

206  

236  

236  

271  

271  

306  

306  

342  

342  

Nom.

  Cable   Weight  

(kg/km)  

46  

59  

59  

76  

76  

93  

93  

120  

120  

161  

161  

178  

178  

206  

202  

202  

224  

224  

258  

258  

296  

296  

339  

339  

384  

384  

429  

429  

90  

©   2014   Belden,   Inc  

All   Rights   Reserved.

 

Although   Belden   makes   every   reasonable   effort   to   ensure   their   accuracy   at   the   time   of   this   publication,   information   and   specifications   described   herein   are   subject   to   error   or   omission   and   to   change   without   notice,   and   the   listing   of   such   information   and   specifications   does   not   ensure   product   availability.

  Belden   provides   the   information   and   specifications   herein   on   an   "AS   IS"   basis,   with   no   representations   or   warranties,   whether   express,   statutory   or   implied.

  In   no   event   will   Belden   be   liable   for   any   damages  

(including   consequential,   indirect,   incidental,   special,   punitive,   or   exemplary   damages)   whatsoever,   even   if   Belden   has   been   advised   of   the   possibility   of   such   damages,   whether   in   an   action   under   contract,   negligence   or   any   other   theory,   arising   out   of   or   in   connection   with   the   use,   or   inability   to   use,   the   information   or   specifications   described   herein.

  All   sales   of   Belden   products   are   subject   to   Belden's   standard   terms   and   conditions   of   sale.

 

3

 

         Technical   Data   Sheet   –   Unshielded   (YY)   PVC   Control   Cable  

3   X4  

3   G4  

4   X4  

4   G4  

5   X4  

5   G4  

7   X4  

7   G4  

9   X4  

14   X2.5

 

14   G2.5

 

16   X2.5

 

16   G2.5

 

18   X2.5

 

18   G2.5

 

20   X2.5

 

20   G2.5

 

2   X4  

Cable  

Description  

3   X2.5

 

3   G2.5

 

4   X2.5

 

4   G2.5

 

5   X2.5

 

5   G2.5

 

7   X2.5

 

7   G2.5

 

9   X2.5

 

9   G2.5

 

10   X2.5

 

10   G2.5

 

12   X2.5

 

12   G2.5

 

9   G4  

10   X4  

10   G4  

12   X4  

12   G4  

2   X6  

3   X6  

3   G6  

4   X6  

4   G6  

5   X6  

5   G6  

7   X6  

7   G6  

9   X6  

3  

3  

4  

4  

5  

5  

7  

7  

9  

14  

14  

16  

16  

18  

18  

20  

20  

2  

5  

7  

7  

9  

9  

10  

10  

12  

12  

No.

  Of  

Cores  

3  

3  

4  

4  

5  

9  

10  

10  

12  

12  

2  

3  

3  

4  

4  

5  

5  

7  

7  

9  

Part   Code  

9G4  

10X4  

10G4  

12X4  

12G4  

2X6  

3X6  

3G6  

4X6  

4G6  

5X6  

5G6  

7X6  

7G6  

9X6  

3X4  

3G4  

4X4  

4G4  

5X4  

5G4  

7X4  

7G4  

9X4  

10X2.5

 

10G2.5

 

12X2.5

 

12G2.5

 

14X2.5

 

14G2.5

 

16X2.5

 

16G2.5

 

18X2.5

 

18G2.5

 

20X2.5

 

20G2.5

 

2X4  

3X2.5

 

3G2.5

 

4X2.5

 

4G2.5

 

5X2.5

 

5G2.5

 

7X2.5

 

7G2.5

 

9X2.5

 

9G2.5

 

4  

4  

4  

4  

4  

4  

4  

4  

4  

2.5

 

2.5

 

2.5

 

2.5

 

2.5

 

2.5

 

2.5

 

2.5

 

4  

Nom.

  Conductor  

Size   (mm²)  

2.5

 

2.5

 

2.5

 

2.5

 

2.5

 

2.5

 

2.5

 

2.5

 

2.5

 

2.5

 

2.5

 

2.5

 

2.5

 

2.5

 

4  

4  

4  

4  

4  

6  

6  

6  

6  

6  

6  

6  

6  

6  

6  

9.80

 

9.80

 

10.90

 

10.90

 

12.00

 

12.00

 

13.30

 

13.30

 

16.60

 

16.20

 

16.20

 

17.30

 

17.30

 

18.30

 

18.30

 

19.50

 

19.50

 

9.10

 

Nom.

  Cable  

Diameter   (mm)  

8.40

 

8.40

 

9.30

 

9.30

 

10.30

 

10.30

 

11.30

 

11.30

 

14.10

 

14.10

 

14.80

 

14.80

 

15.40

 

15.40

 

16.60

 

17.50

 

17.50

 

18.10

 

18.10

 

10.90

 

11.70

 

11.70

 

13.10

 

13.10

 

14.50

 

14.50

 

16.00

 

16.00

 

20.10

 

181  

181  

235  

235  

293  

293  

386  

386  

516  

487  

487  

561  

561  

635  

635  

710  

710  

137  

Nom.

  Cable   Weight  

(kg/km)  

118  

118  

152  

152  

189  

189  

245  

245  

328  

328  

365  

365  

424  

424  

516  

577  

577  

673  

673  

202  

270  

270  

351  

351  

439  

439  

578  

578  

779  

©   2014   Belden,   Inc  

All   Rights   Reserved.

 

Although   Belden   makes   every   reasonable   effort   to   ensure   their   accuracy   at   the   time   of   this   publication,   information   and   specifications   described   herein   are   subject   to   error   or   omission   and   to   change   without   notice,   and   the   listing   of   such   information   and   specifications   does   not   ensure   product   availability.

  Belden   provides   the   information   and   specifications   herein   on   an   "AS   IS"   basis,   with   no   representations   or   warranties,   whether   express,   statutory   or   implied.

  In   no   event   will   Belden   be   liable   for   any   damages  

(including   consequential,   indirect,   incidental,   special,   punitive,   or   exemplary   damages)   whatsoever,   even   if   Belden   has   been   advised   of   the   possibility   of   such   damages,   whether   in   an   action   under   contract,   negligence   or   any   other   theory,   arising   out   of   or   in   connection   with   the   use,   or   inability   to   use,   the   information   or   specifications   described   herein.

  All   sales   of   Belden   products   are   subject   to   Belden's   standard   terms   and   conditions   of   sale.

 

4

 

         Technical   Data   Sheet   –   Unshielded   (YY)   PVC   Control   Cable  

3   G25  

4   X25  

4   G25  

5   X25  

5   G25  

7   X25  

7   G25  

2   X35  

3   X35  

3   G16  

4   X16  

4   G16  

5   X16  

5   G16  

7   X16  

7   G16  

2   X25  

3   X25  

3   G35  

4   X35  

4   G35  

5   X35  

5   G35  

Cable  

Description  

9   G6  

2   X10  

3   X10  

3   G10  

4   X10  

4   G10  

5   X10  

5   G10  

7   X10  

7   G10  

9   X10  

9   G10  

2   X16  

3   X16  

Part   Code  

3G25  

4X25  

4G25  

5X25  

5G25  

7X25  

7G25  

2X35  

3X35  

3G35  

4X35  

4G35  

5X35  

5G35  

9X10  

9G10  

2X16  

3X16  

3G16  

4X16  

4G16  

5X16  

5G16  

7X16  

7G16  

2X25  

3X25  

9G6  

2X10  

3X10  

3G10  

4X10  

4G10  

5X10  

5G10  

7X10  

7G10  

3  

4  

4  

5  

5  

7  

7  

2  

3  

3  

4  

4  

5  

5  

3  

4  

4  

5  

5  

7  

7  

2  

3  

4  

5  

5  

7  

7  

9  

9  

2  

3  

No.

  Of  

Cores  

9  

2  

3  

3  

4  

25  

25  

25  

25  

25  

25  

25  

35  

35  

35  

35  

35  

35  

35  

16  

16  

16  

16  

16  

16  

16  

25  

25  

Nom.

  Conductor  

Size   (mm²)  

6  

10  

10  

10  

10  

10  

10  

10  

10  

10  

10  

10  

16  

16  

21.30

 

23.80

 

23.80

 

26.50

 

26.50

 

29.30

 

29.30

 

22.20

 

23.70

 

18.10

 

20.20

 

20.20

 

22.40

 

22.40

 

24.80

 

24.80

 

19.80

 

21.30

 

23.70

 

26.40

 

26.40

 

29.50

 

29.50

 

Nom.

  Cable  

Diameter   (mm)  

20.10

 

13.90

 

14.90

 

14.90

 

16.60

 

16.60

 

18.40

 

18.40

 

20.40

 

20.40

 

25.60

 

25.60

 

16.80

 

18.10

 

1038  

1371  

1371  

1739  

1739  

2359  

2359  

988  

1360  

685  

899  

899  

1136  

1136  

1526  

1526  

758  

1038  

1360  

1805  

1805  

2317  

2317  

Nom.

  Cable   Weight  

(kg/km)  

779  

337  

454  

454  

594  

594  

747  

747  

994  

994  

1350  

1350  

505  

685  

 

 

 

 

 

 

 

 

 

 

 

©   2014   Belden,   Inc  

All   Rights   Reserved.

 

Although   Belden   makes   every   reasonable   effort   to   ensure   their   accuracy   at   the   time   of   this   publication,   information   and   specifications   described   herein   are   subject   to   error   or   omission   and   to   change   without   notice,   and   the   listing   of   such   information   and   specifications   does   not   ensure   product   availability.

  Belden   provides   the   information   and   specifications   herein   on   an   "AS   IS"   basis,   with   no   representations   or   warranties,   whether   express,   statutory   or   implied.

  In   no   event   will   Belden   be   liable   for   any   damages  

(including   consequential,   indirect,   incidental,   special,   punitive,   or   exemplary   damages)   whatsoever,   even   if   Belden   has   been   advised   of   the   possibility   of   such   damages,   whether   in   an   action   under   contract,   negligence   or   any   other   theory,   arising   out   of   or   in   connection   with   the   use,   or   inability   to   use,   the   information   or   specifications   described   herein.

  All   sales   of   Belden   products   are   subject   to   Belden's   standard   terms   and   conditions   of   sale.

 

5

         Technical   Data   Sheet   –   Unshielded   (YY)   PVC   Control   Cable  

 

 

Sheath   /   Jacket   Colour  

   

Colour     

1) Grey   (RAL   7001)  

2) Black    

3) Blue    

 

 

4) Orange   

5) Violet       

 

 

Packaging  

Packaging

1) Coil

 

 

Type

 

 

2) Plastic   reel    

3) Wooden   reel    

 

 

Put ‐ up   Length  

 

 

 

Putup   Length    

1) 50   Meters *    

 

2) 100   Meters *    

3) 200   Meters *    

4) 305   Meters    

5) 500   Meters *    

6) 1000   Meters *    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable   Requirement    

≤  20kg        

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Colour   Code  

G8U  

010

006

 

 

003  

007  

 

 

 

Packaging   Code  

C  

P  

W  

 

 

 

 

 

 

 

Putup   Length   Code  

50M  

100M

200M

 

   

305M

500M

 

 

1000M  

 

*Applicable   only   for   certain   part   codes,   please   check   with   Belden   for   more   information.

 

 

 

Stock   Code   Selection   Procedure:  

   

 

5 G 0 .

5

Se lect the part code from

Table A

G 8 U

Select the sheath / jacket color code

P

Select packaging type

3 0 5 M

Select the putup length code

5 G 0 .

5 G 8 U P 3 0 5 M

Cable   Stock   Code   =   5G0.5

  G8UP305M

©   2014   Belden,   Inc  

All   Rights   Reserved.

 

Although   Belden   makes   every   reasonable   effort   to   ensure   their   accuracy   at   the   time   of   this   publication,   information   and   specifications   described   herein   are   subject   to   error   or   omission   and   to   change   without   notice,   and   the   listing   of   such   information   and   specifications   does   not   ensure   product   availability.

  Belden   provides   the   information   and   specifications   herein   on   an   "AS   IS"   basis,   with   no   representations   or   warranties,   whether   express,   statutory   or   implied.

  In   no   event   will   Belden   be   liable   for   any   damages  

(including   consequential,   indirect,   incidental,   special,   punitive,   or   exemplary   damages)   whatsoever,   even   if   Belden   has   been   advised   of   the   possibility   of   such   damages,   whether   in   an   action   under   contract,   negligence   or   any   other   theory,   arising   out   of   or   in   connection   with   the   use,   or   inability   to   use,   the   information   or   specifications   described   herein.

  All   sales   of   Belden   products   are   subject   to   Belden's   standard   terms   and   conditions   of   sale.

 

6