House Wiring Projects Class Name: Grade 11 Semester 2 Student Name: Bradley Larocque Assessed On: 02/05/2014 Assessed By: Kent Brewer Items Beginning (1-49 pts.) Developing (50-69 pts.) Accomplished (70-100 pts.) Mounting and Bonding of Device Boxes More than half the boxes incorrect with regard to height, # of screws, level, or depth. More than half the boxes(including the panel) without proper bonding. Less than half the boxes incorrect with regard to height, # of screws, level, or depth. Less than half the boxes(including the panel) without proper bonding. All boxes mounted correctly with regard to height, # of screws, level, or depth. All of the boxes(including the panel) with proper bonding methods. Cable Installation Minimal # of the supports are correctly sized, placed and installed(straight and not too deep). Very few of the installed conductors are at correct depth from stud edge. Majority of the supports are correctly sized, placed and installed(straight and not too deep). Majority of the conductors installed are at correct depth from stud edge. All of the supports are correctly sized, placed and installed(straight and not too deep). All of the conductors are installed at the correct depth from stud edge. Wiring Terminations and Practices Very few wires are installed in the boxes with 1/4" or outer sheath, minimum of 6" internally, bond wire connected to device, no bare conductor showing around the wire nut, minimal bare conductor visible at terminal screws and wraps are clockwise. Minimal # of box clamps and connectors are tightened properly avoiding short circuits. Some splices contain minimum of three equal wraps. Majority of wires are installed in the boxes with 1/4" or outer sheath, minimum of 6" internally, bond wire connected to device, no bare conductor showing around the wire nut, minimal bare conductor visible at terminal screws and wraps are clockwise. Majority of box clamps and connectors are tightened properly avoiding short circuits. Majority of splices contain minimum of three equal wraps. All wires are installed in the boxes with 1/4" or outer sheath, minimum of 6" internally, bond wire connected to device, no bare conductor showing around the wire nut, minimal bare conductor visible at terminal screws and wraps are clockwise. All box clamps and connectors are tightened properly avoiding short circuits. All splices contain minimum of three equal wraps. Workmanship Minimal amount of conductor is installed without twists and at right angles with supports in places other than those required. Very few wires within the distribution panel are bent at right angles, spaced properly and without splices. Less than half of the devices and associated covers are properly attached, consistent in direction and level. A majority of conductor is installed without twists and at right angles with supports in places other than those required. Almost all wires within the distribution panel are bent at right angles, spaced properly and without splices. More than half of the devices and associated covers are properly attached, consistent in direction and level. All of the conductor is installed without twists and at right angles with supports in places other than those required. All wires within the distribution panel are bent at right angles, spaced properly and without splices. All devices and associated covers are properly attached, consistent in direction and level. Circuit Functionality Circuit(s) work initially but a short circuit occurs. Some of the circuit(s) work, but not entirely. Every circuit(s) work properly in their entirety. Comment: Front Entrance Created With ForAllRubrics | www.forallrubrics.com | Page 1