Surge Protection For Business-Critical ContinuityTM Edco™ TER Series Single Pair Medium Duty Low Voltage Zone/Horn/Strobe/Data The Edco TER surge suppressor directly installs onto electronic circuit wiring terminal screws. This close proximity preserves Edco TER’s response time, clamping level and ground reference by eliminating lead lengths. The Edco TER’s miniature size fits directly inside fire or security panels, CCTV housings and other system electronic enclosures. These features maximize surge suppression performance while reducing hardware and labor costs to install. General Technical Specifications Operating Voltage 40 VDC Clamping Voltage 43 VDC Operating Current 2A Peak Pulse Current (10 x 1000 µs) 043 = 46.5A Frequency Range 0 to 20 MHz Insertion Loss SPD Technology Connection Type <0.1 dB at 20 MHz Silicon Avalanche Diode (SAD) Terminal block w/compression lugs Terminals accept up to 12 AWG Operating Temperature Dimensions (Inches) -40°C to +85°C 1.3H x 0.4W x 2.0L Weight Certifications Warranty Features Fits Euro style and barrier strip terminals Automatic recovery Single pair protection High energy silicon avalanche technology UL 497B listed 0.6 oz UL 497B 5 years Operating current > 2 Amps Compact size: 1.3" x 0.4" x 2" (HxWxL) 5 year warranty Ordering Information Fits in series with circuit wires at the terminal screws Zone, Buss, Loop, Data, Receive, Bell, Horn, Strobe, Pan/Tilt & CCTV TER-043 (For 12 VDC, 24 VDC, 25 VAC Systems) Installation 1. Install zone or loop circuit wires (1 pair) at the vacant end of the Edco TER. Torque terminal screws to 3.5 LB-IN max. 2. Slip the Edco TER’s Rigid Mounting Prongs into the panels designated Zone or Loop terminals and tighten. 3. Using a 16-12 AWG solid wire, attach all Edco TERs via the center ground terminal. Run this wire to your panel’s “single point” AC power ground or building approved ground. Torque terminal screws to 6.0 LB-IN max. CAUTION A.Never install data wiring during a lightning storm. B.Disconnect data line before installing the protection module. C.These protectors are intended for indoor use on communication loop circuits which have been isolated from the Public Switch Telephone Network. D.The communication loop circuits shall not be exposed to accidental contact with the electric light or power conductors. The protectors shall be installed per the applicable requirements of the National Electric Code, ANSI/NFPA 70. Emerson Network Power. The global leader in enabling Business-Critical ContinuityTM. AC Power Embedded Computing Outside Plant Racks and Integrated Cabinets Connectivity Embedded Power Power Switching & Control Services DC Power Infrastructure Management & Monitoring Precision Cooling Surge Protection Emerson Network Power Contact information www.emersonnetworkpower.com/surge Headquarters Surge Protection 100 Emerson Parkway Binghamton, New York 13905 T: (607) 721-8840 T: (800) 288-6169 F: (607) 722-8713 E: contactsurge@emerson.com IO-50120 11/11 Rev.4 Printed in USA Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2011 Emerson Electric Co.