DPM 125 3½ Digit LCD Module No.: 695 - Page 1 of 2 This compact LCD DPM is ideally suited for low or high volume applications. It features an exceptionally large display in a miniature package. The meter will plug directly into a SIL socket or can be panel mounted using the snap in bezel provided. The low profile bezel incorporates a flat reverse printed window giving a superb appearance that cannot be damaged or rubbed of by contact. 12.5mm (0.5“) Digit Height Logic Selectable Decimal Points Auto-zero -+ Auto-polarity 200mV d.c Full Scale Reading (F.S.R.) Low Battery Indication SCALING Two resistors may be used to alter the full scale reading of the meter - see table. Note that the meter will have to be re-calibrated by adjusting the calibration pot . Ra Stock Number Standard Meter INPUT Rb IN LO (8) - Required F.S.R. 2V 20V 200V 2kV 200mA 2mA 20mA 200mA Note Ra Rb 910k 1M 1M 10M 0R 0R 0R 0R 100k 10k 1k 1k 1k 100R 10R 1R Min. Accuracy (overall error) * Linearity Sample rate Operating temperature range Temperature stability Supply voltage (V+ to V-) Supply current Input leakage current (Vin = 0V) IN HI (7) + DPM 125 Specification Typ. Max. Unit 0.05 0.1 ±1 % (±1 count) count samples/sec °C ppm/°C V mA pA 3 0 50 100 9 150 1 7.5 14 10 * To ensure maximum accuracy, re-calibrate periodically. NOTE Ensure Ra is rated for high voltage use. DIMENSIONS All dimensions in mm (inches) a 48 (1.89) b a. 1.50 (0.06) b. 9.00 (0.35) c. 5.00 (0.20) d. 1.60 (0.06) e. 4.00 (0.16) f. 10.4 (0.41) g. 7.50 (0.30) h. 2.54 (0.10) i. 0.50 (0.02) Panel cut-out 45 x 22.2 (1.77 x 0.87) 24 (0.94) 14.0 (0.55) 31.0 (1.22) Viewing Area showing display in TEST mode d c g 18.2 (0.72) REAR VIEW 9 ON BOARD SOLDER LINKS DP3 DP2 DP1 1 1 h 11 4 DP1 DP3 12 DP2 IN HI V+ VTEST COM IN LO ROH RHI RLO f 20.4 (0.80) 40.5 (1.59) 38.0 (1.50) i 3 2 12 e 1 PANEL FITTING Fit the bezel to the front of the panel and then locate the meter into the bezel from behind. Alternatively the meter and bezel may be assembled before fitting into the front of the panel but care must be taken not to use excessive force. Finally fit the window into the front of the bezel. Specifications liable to change without prior warning DPM 125 Issue 7 06/2010 S.L. Applies to DPM 125/2 LASCAR ELECTRONICS LTD. LASCAR ELECTRONICS INC. LASCAR ELECTRONICS (HK) LTD. MODULE HOUSE, WHITEPARISH, WILTSHIRE SP5 2SJ UK TEL: +44 (0)1794 884567 FAX: +44 (0)1794 884616 E-mail: sales@lascar.co.uk 4258 WEST 12th STREET, ERIE, PA 16505 USA TEL: +1 (814) 835 0621 FAX: +1 (814) 838 8141 E-mail: us-sales@lascarelectronics.com 8th FLOOR, CHINA AEROSPACE CENTRE, 143 HOI BUN ROAD, KWUN TONG, KOWLOON, HONG KONG TEL: +852 2389 6502 FAX: +852 2389 6535 E-mail: saleshk@lascar.com.hk No.: 695 - Page 2 of 2 PIN FUNCTIONS 1. 2. 3. 4. DP1 DP2 DP3 TEST 5. 6. 7. 8. 9. VV+ IN HI INLO COM 10. RLO 11. RHI 12. ROH 199.9 19.99 Connect to V+ to display required DP. 1.999 Connect to V+ to display segments as illustrated. It should not be operated for more than a few seconds as the d.c. voltage applied to the LCD may 'burn' the display. This pin is normally at 5V below V+ and is the ground for the digital section of the meter. It can be used to power external logic up to a maximum of 1mA. Negative power supply connection. Positive power supply connection. Positive measuring differential input. Analogue inputs must be no closer than 1V to either the positive or negative supply. Negative measuring differential input. The ground for the analogue section of the A/D converter, held actively at 2.8V (nom.) below V+. COM must not be allowed to sink excessive current (>100mA) by connecting it directly to a higher voltage. Negative input for reference voltage (can be connected to COM via Link 3). Positive input for reference voltage (connected via Link 1 to ROH). Positive output from internal reference. SAFETY To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s pins must not exceed 60Vdc. If voltages to the measuring inputs do exceed 60Vdc, then fit scaling resistors externally to the module. The user must ensure that the incorporation of the DPM into the user’s equipment conforms to the relevant sections of BS EN 61010 (Safety Requirements for Electrical Equipment for Measuring, Control and Laboratory Use). VARIOUS OPERATING MODES 6 V+ + ±200mV - 7 8 V+ 6 V+ 7 IN HI + ±200mV 8 - 510K 7 14V max 7V min IN LO IN LO 0V 1V min. V5 VCheck Links 2 & 3 are SHORTED. Measuring a floating voltage source of 200mV full scale. 6 V+ 7 IN HI V1 6 V+ + 7 IN HI 8 IN LO V2 R=0.2 IF.S.R. V5 V- V+ Measuring current. Supply MUST be isolated. Specifications liable to change without prior warning - 10 REF LO V5 Issue 7 V5 V- V+ 6 7 IN HI V+ 100K 6R2 SET 5K 8 ZERO 9 IOUT V- Measuring the ratio of two voltages. Reading = 1000 V1/V2 50mV< V2<200mV V1<2V2. DPM 125 IN LO IIN 06/2010 IN LO COM V5 VCheck Link 3 is SHORTED. Check Links 1 & 4 are OPEN. Check Links 2 & 3 are SHORTED. 8 Measuring a supply voltage. (min. 7.5V, max. 14V). + 11 REF HI 8 IN LO IN HI Check Link 3 is SHORTED. Split supply operation. V+ SUPPLY VOLTAGE 510K V- 6 V+ 10K V5 Check Link 3 is SHORTED. R- - V+ V+ IN HI + Normally OPEN Solder to SHORT Normally SHORTED Cut to OPEN ON-BOARD LINKS: In order to quickly and easily change operating modes for different applications, the meter has several on-board links. They are designed to be easily cut (opened) or shorted (soldered). Do not connect more than one meter to the same power supply if the meters cannot use the same signal ground. Taking any input beyond the power supply rails will damage the meter. Measuring 4-20mA to read 0-999. (supply MUST be isolated). S.L. Applies to DPM 125/2