Build interior walls and ceilings faster using drylining methods

Knauf Wetroom Solutions | Installation
Build interior walls and ceilings
faster using drylining methods
Knauf Wetroom Solutions with AQUAPANEL® Technology Inside
Be certain,
choose AQUAPANEL®
Knauf Wetroom Solutions with
AQUAPANEL® Technology Inside:
improved performance with lower
costs and installation time
G i v e s pa c e
Knauf Wetroom Solutions with AQUAPANEL® Technology
and mildew. Knauf Wetroom Solutions enable installers to
Give space to more room with Knauf Wetroom Solutions. It’s an
Inside are the more economical, sustainable and high-
avoid the time-consuming methods necessary with brick and
invitation to raise the roof of possibility with a wall system that gives
performing solution to tile backing in wet or damp areas.
mortar; and they can do it with greater flexibility and the
ability to contend with specific needs such as extra moisture
Constructed from aggregated Portland cement with coated
Contents
Product range___________________________________ 4
Installation of Knauf Wetroom Solutions with
space to new ways of thinking and smarter ways of building.
AQUAPANEL® Technology Inside__________________ 23
Surface finishing________________________________ 25
Be limited only by your ambition, not the materials you use.
Installation details_______________________________ 34
protection or sound insulation.
glass fibre mesh embedded surfaces, these unique cement
boards are 100% water-resistant and resistant to mould
Processing/handling_____________________________ 22
Ceiling installation______________________________ 36
www.AQUAPANEL.com
Tool recommendations___________________________ 43
Knauf Wetroom Solutions | Systems
A better way to build
interior walls and ceilings
in wet and humid areas
Knauf Wetroom Solutions | Techniques
Technical solutions for
interior walls and ceilings
Knauf Wetroom Solutions with AQUAPANEL® Technology Inside
Reference of additional documentation_____________ 45
Knauf Wetroom Solutions with AQUAPANEL® Technology Inside
Be certain,
Be certain,
choose AQUAPANEL®
choose AQUAPANEL®
See additional documentation for more detailed
information on Knauf Wetroom Solutions
2 _ 3
Product range
Interior walls/ceilings
Lining
Approved accessories: Walls
AQUAPANEL® Cement Board Indoor
AQUAPANEL® Joint Adhesive (PU)
Aggregated Portland cement
board with coated glass fibre
mesh embedded in back and front
surfaces. The ends are square cut
and the edges reinforced and
finished smoothly (EasyEdge™).
Thickness: 12.5 mm
Width: 900 mm
Length: 1200, 2400, 1250,
2500 mm
Weight: approx. 15 kg/m2
AQUAPANEL® Joint Adhesive
(PU) is used to bond individual
AQUAPANEL® Cement Board
Indoor panels.
Packaging:
1200/1250 mm length:
50 pieces/pallet
2400/2500 mm length:
25 pieces/pallet
Building material category: A1
Fastening
AQUAPANEL® Board Primer
AQUAPANEL® Maxi Screws
AQUAPANEL® Maxi Screws
have been specially developed
for fixing AQUAPANEL® Cement
Board Indoor onto frameworks
of differing thicknesses.
Both needlepoint and drill point
versions with countersunk are
available. AQUAPANEL® Maxi
Screws can be used for both wall
and ceiling applications in
interior and exterior applications.
Screws have a special corrosionproof coating, which gives a
guaranteed 720 hours corrosion
resistance in a salt spray test.
Timber framework
AQUAPANEL Maxi Screw SN 25
✓
AQUAPANEL® Maxi Screw SN 39
✓
AQUAPANEL® Maxi Screw SN 55
Double layer
Metal thickness 0.8 – 2.0 mm
Triple layer
Single layer
Double layer
✓
Single layer
Double layer
✓
✓
AQUAPANEL® Q4 Finish is a
ready-to-use and water-repellent
skim coat for high-quality finely
finished surfaces up to Q4
standard.
Application: Above the tiled
area or as an all-over skim
coating over AQUAPANEL®
Joint Filler & Skim Coating
– white & AQUAPANEL®
Interior Reinforcing Mesh.
Coverage: approx.
1.7 kg/m2/mm coating depth
Packaging: 20 kg/bucket
Coverage: approx. 3.5 kg/m2
Note: Machine processing is
possible with PFT RiTMO (230V)
(A3-2L pump unit, SWiNG
sprayer, LK 402 air compressor)
✓
AQUAPANEL Maxi Screw SB 25
✓
AQUAPANEL® Maxi Screw SB 39
✓
®
Coverage: approx. 40 - 60 g/m2
Dilution: 1: 2 with water
Packaging:
15 l/bucket
2.5 l/bucket
AQUAPANEL® Q4 Finish
Metal thickness 0.6 – 0.7 mm
Single layer
Packaging:
SN 39: 500 pieces/carton
SN 25: 1000 pieces/carton
SN 55: 250 pieces/carton
SB 39: 250 pieces/carton
SB 25: 250 pieces/carton
AQUAPANEL® Board Primer is a
ready-to-use synthetic dispersion
for priming AQUAPANEL®
Cement Board Indoor panels to
provide maximum adhesion of
tiles and plasters.
Collated screws available
on request.
Metal framework
®
Coverage: approx. 50 ml/m2
(approx. 6.5 m2 per cartridge)
Packaging:
310 ml/cartridge
20 cartridges/carton
Note: For joint reinforcement, use
Knauf glass fibre cover strips.
✓
AQUAPANEL® Joint Filler & Skim Coating – white
AQUAPANEL® Joint Filler & Skim
Coating – white is a cementbound material for skim coating
AQUAPANEL® Cement Board
Minimum layer thickness 4 mm
Packaging: 10 kg/bag
Indoor beyond the tiled area.
AQUAPANEL® Reinforcing Mesh
must be embedded.
4 _ 5
Product range
Interior walls/ceilings
Approved accessories: Ceilings
AQUAPANEL® Reinforcing Mesh
AQUAPANEL® Reinforcing Mesh
is a glass fibre fabric used to
reinforce AQUAPANEL® Joint
Filler & Skim Coating – white.
AQUAPANEL® Tape
Coverage: approx. 1.1 m2/m2
Packaging:
100 cm wide roll, 50 m long
30 rolls/carton
AQUAPANEL® Tape is a glass
fibre tape with an alkali-resistant
coating. AQUAPANEL® Interior
Tape is used to reinforce joints
in interior ceiling applications.
It is embedded into the
AQUAPANEL® Joint Filler
Additional accessories
Coverage: approx. 2.1 m/m2
Packaging:
10 cm wide roll, 50 cm long
20 rolls/carton
AQUAPANEL® Joint Filler – grey
AQUAPANEL® Traverse
AQUAPANEL® Traverses are
used for attaching light console
loads to walls constructed from
AQUAPANEL® Cement Board
Indoor.
– grey or AQUAPANEL® Joint
Filler & Skim Coating – white.
Axis frame dimensions:
600/625 mm
Height: approx. 290 mm
Plate thickness:
0.75 mm with special
corrosion protection layer
M type: Without impregnated
wood packing
MH type: With core-impregnated
MDF filler, approx. 18 mm thick
AQUAPANEL® Joint Filler – grey
is a cement-bound filling material
for setting AQUAPANEL® Tape
for ceiling applications.
Coverage: approx. 0.7 kg/m2
Packaging: 10 kg/bag
AQUAPANEL® Board Primer
AQUAPANEL® Access Doors
AQUAPANEL® Access Doors
can be installed in partition
and plumbing walls as well as
in ceilings.
Sizes: 300 x 300 mm
400 x 400 mm, 500 x 500 mm
Other sizes (e.g. tile dimension)
available on request.
Please indicate application
details when ordering.
AQUAPANEL® Board Primer is a
ready-to-use synthetic dispersion
for priming AQUAPANEL®
Cement Board Indoor panels to
provide maximum adhesion of
tiles and plasters.
Coverage: approx. 40 - 60 g/m2
Dilution: 1: 2 with water
Packaging:
15 l/bucket
2.5 l/bucket
Type 1:
AQUAPANEL® Access Door
Splash Water Protection
Type 2:
AQUAPANEL® Access Door
Humid Rooms
6 _ 7
Product range
Product range
Interior ceilings
Interior walls + Interior ceilings
Air-tightness accessories
AQUAPANEL® Joint Filler & Skim Coating – white
AQUAPANEL Joint Filler &
Skim Coating – white is a
cement-bound material for skim
coating AQUAPANEL® Cement
Board Indoor beyond the tiled
area. AQUAPANEL® Reinforcing
Mesh must be embedded.
®
LDS 100 (vapour barrier)
Coverage: approx. 3.5 kg/m
Minimum layer thickness 4 mm
Packaging: 10 kg/bag
2
Note: Machine processing is
possible with PFT RiTMO (230V)
(A3-2L pump unit, SWiNG
sprayer, LK 402 air compressor)
AQUAPANEL® Reinforcing Mesh
AQUAPANEL® Reinforcing Mesh
is a glass fibre fabric used to
reinforce AQUAPANEL® Joint
Filler & Skim Coating – white.
Vapour control layer made
from polypropylene special foil,
LDS 100 is resistant to aging
(sd-value ≥ 100m). Conforms to
EN 13859 and ETAG 007.
Width: 2 m or 4 m
Length: 50 m or 25 m
10 m2/roll
Packaging: 46 or 100 rolls/pallet
LDS 2 Silk (vapour barrier)
Coverage: approx. 1.1 m2/m2
Packaging:
100 cm wide roll, 50 m long
30 rolls/carton
Vapour control layer made from
polypropylene spunbonded
fabric, LDS 2 Silk is resistant to
aging and is resistant to tearing
(sd-value ≥ 2m). Conforms to
conforms to EN 13984 and
ETAG 007.
Width: 1.50 m or 2 m
Length: 50 m
m2/roll: 75 m2 or 100 m2
Packaging: 20 rolls/pallet
Self-adhesive sealant tape
which is paper-based. For use
in interior applications to bond
overlapping layers.
Width: 60 mm
Length: 40 m
Thickness: 0.35 mm
Packaging: 8 rolls/carton
Self-adhesive sealant tape which
is reinforced polyethylene-based
with either full surface or halfsurface covering paper. For
exterior applications where it
is used as an elastic sealant for
corners, windows and openings.
Width: 60 mm
Length: 25 m
Thickness: 0.28 mm
Packaging: 10 rolls/carton
LDS Soliplan
AQUAPANEL® Q4 Finish
AQUAPANEL® Q4 Finish is a
ready-to-use and water-repellent
skim coat for high-quality finely
finished surfaces up to Q4
standard.
Ceiling use: Only use as all-over
white skim coat on top of
AQUAPANEL® Joint Filler &
Skim Coating – white and
AQUAPANEL® Reinforcing Mesh.
Glass fibre joint covering strip
GLASS FIBRE JOINT COVERING
STRIPS are used to reinforce
interior joints and to avoid
cracks. It can be embedded
in gypsum fillers and
AQUAPANEL® Q4 Finish.
Coverage: approx.
1.7 kg/m2/mm coating depth
Packaging: 20 kg/bucket
LDS Solifit/ LDS Solitwin
Width: 50 mm
Length: 25 m/roll
Packaging: 40 rolls/carton
8 _ 9
Product range
Interior walls + Interior ceilings
Lining with Gypsum Board
Gypsum Board
The ideal standard interior lining
for Interior Walls. It offers an
economic building solution and is
ideal for all types of living spaces
without additional requirements.
Width: 1250 mm
Length: 2000/2500/
2600/2750/3000 mm
Thickness: 12.5 mm
Weight: 9.2 kg/m2
Number of boards: 50
Net weight per pallet:
min. 1150/max. 1725 kg
The ideal interior lining for
Knauf Wetroom Solutions where
a robust solution is required.
Especially suited to shaft wall
construction.
Width: 625 mm
Length: 2000/2500/
2600 mm
Thickness: 25 mm
Weight: 21 kg/m2
Number of boards: 20
Net weight per pallet:
min. 525/max. 682.5 kg
Massivbauplatte
Impregnated Gypsum Board
The ideal interior lining for
Knauf Wetroom Solutions for
damp rooms in living areas
where there is occasional
exposure to water spray. Boards
remain impervious to moisture
and create an even surface for
untiled areas. They are ideal for
painting or for further surface
finishing (with appropriate sealing
for gaps, edges and surfaces).
The ideal interior lining for Knauf
Wetroom Solutions where higher
mechanical surface resistance is
required. This higher density
impregnated fire-rated board also
achieves a higher sound
insulation than standard boards
with the same system build-up.
Width: 1250 mm
Length: 2000/2500 mm
Thickness: 12.5 mm
Weight: 13.5 kg/m2
Width: 1250 mm
Length: 2000/2500/
2600/3000 mm
Thickness: 12.5 mm
Weight: 10.2 kg/m2
Number of boards: 50
Net weight per pallet:
min. 1275/max. 1912.5 kg
Diamant
Number of boards: 40
Net weight per pallet:
min. 1350/max. 1687.5 kg
10 _ 11
Product range
Product range
Interior walls + Interior ceilings
Fastening of Gypsum Board
Vidiwall Gypsum Fibre Board
The ideal interior lining for Knauf
Wetroom Solutions where higher
mechanical surface resistance is
required. (Performance is
comparable to Diamant Hard
Gypsum Board, however, board
is not impregnated.)
Drywall Screw
Width: 1250 mm
Length: 2000/2540/
2570/3000 mm
Thickness: 12.5 mm
Weight: 14.8 kg/m2
Number of boards: 40
Net weight per pallet:
min. 1480/max. 2220 kg
High quality screws for dry lining
with Gypsum Boards on metal
frameworks (metal thicknesses up
to 0.7 mm). For single/double/
triple layer (depending on
length). Suitable for fire-resistant
and sound insulating walls.
Length: 25/35/45/55 mm
Screw head diameter:
3.5 mm
Packaging:
TN 3.5 x 25, 250 pieces/carton
TN 3.5 x 25, 1000 pieces/carton
TN 3.5 x 35, 250 pieces/carton
TN 3.5 x 35, 1000 pieces/carton
TN 3.5 x 45, 250 pieces/carton
TN 3.5 x 45, 1000 pieces/carton
TN 3.5 x 55, 1000 pieces/carton
Joint compounds and plasters for Gypsum Board
Fireboard
The ideal interior lining for Knauf
Knauf Wetroom Solutions where
high fire protection requirements
are critical. This special board
with glass fleece coating is used
for fire-rated linings. In general,
the planking thickness is lower
compared with standard
carton-coated Gypsum Board. An
impregnated version is available:
Impregnated Fireboard.
The ideal interior lining for
Knauf Wetroom Solutions where
high sound reduction is key.
Heavier than Diamant Hard
Gypsum Board.
Width: 625 mm
Length: 2000/2500 mm
Thickness: 12.5 mm
Weight: 17.5 kg/m2
Number of boards: 42
Net weight per pallet:
min. 918.75/max. 1148.44 kg
Width: 1250 mm
Length: 2000 mm
Thickness: 12.5 mm
Weight: 10.7 kg/m2
Number of boards: 50
Net weight per pallet:
min. 1337.5 kg
Uniflott
Uniflott is the standard gypsum
compound that is used for filling
joints of drywall systems and is
applied by hand. This special
gypsum-based, synthetictempered, powdery material
contains mineral filler and
additives for easy application.
It is used for filling of Gypsum
or Composite Boards with HRK
(half-rounded edge) or HRAK (halfrounded tapered edge) without
joint tape (except cut edge).
Packaging:
25 kg/bag
42 bags/pallet
Trias is a gypsum compound
that is used for filling joints of
drywall systems and is applied
by hand. It is adjusted to the
colour of the Gypsum Boards
and has a reduced absorption
after hardening. TRIAS shows
extremely low shrinkage when
drying. This special gypsum-
based, synthetic-tempered,
powdery material contains
additives for easy application.
It is used for hand filling of
Gypsum Boards or Composite
Boards with HRK (half-rounded
edge) or HRAK (half-rounded
tapered edge) without joint tape
on paper covered edges.
Packaging:
25 kg bag
42 bags/pallet
This gypsum-based powdery
material is used for filling joints
of drywall systems and is applied
by hand. It contains suspending
agents and mineral fillers for
application range. It is used for
hand filling of Knauf Boards with
joint tape on paper covered
edges, preferably Joint Tape Kurt.
Packaging:
25 kg bag
40 bags/pallet
Silentboard
Trias
Fugenfüller leicht
12 _ 13
Product range
Readygips
Joint Tape KURT
Readygips consists of synthetic
dispersion as binder and an
exactly set up combination of
particle-sized mineral calcium
sulphate extenders and
suspending agent. It is used for
indoor skimming of Gypsum
Boards. READYGIPS is very easy
to sand and produces a very
fine surface after drying. For
hand filling or machine filling in
combination with Joint Tape Kurt.
Joint Tape Kurt is a 50 mm wide
strip of special paper which is
used to reinforce the joint filling
and edges of Gypsum Boards
and Gypsum Fibre Boards.
Particulary resistant to tearing.
Packaging:
Pail:
20 kg pail
24 pails/pallet
Bag:
25 kg bag
12 bags/pallet
JOINTFILLER SUPER
Width: 50 mm
Length: 25 m/roll, 75 m/roll
Flächendicht
JOINTFILLER SUPER is used for
joint filling in combination with
Joint Tape KURT and for
full-surface skim coating also in
combination with UNIFLOTT. It
contains organic binders and a
balanced combination of
suspending agents and mineral
fillers and experiences very little
shrinkage when drying.
JOINTFILLER SUPER can be
applied by hand or by machine.
FLÄCHENDICHT is a liquid
sealant comprising synthetic
latex and mineral fillers. As it
dries, it forms a waterproof,
elastic seam.
Packaging:
20 kg bag
42 bags/pallet
Multi-Finish/Multi-Finish M
Flächendichtband
MULTI-FINISH is a synthetic
modified, gypsum-based filling
compound and thin plaster. It is
suitable for interior applications
such as efficient filling of uneven
and coarse surfaces, holes and
slots. MULTI-FINISH is particularly
suitable for the creation of
surfaces which comply with
surface quality level Q4. In
addition, MULTI-FINISH is
suitable for the creation of
premium interior coloured
decorative surface design.
Easyputz decorative plaster is
a pure mineral plaster which can
be used to create a structural
finish for indoor rooms on top of
Gypsum Board. It is ready-made,
solvent-free, free of preservatives
and perfectly mixed for optimal
processing characteristics.
Easyputz is available with 0.5
mm and with 1 mm grain and
can be applied by pump or by
hand. Many colour variants are
possible as it can be pigmented
with COMPACT-COLOR.
PFT RITMO powercoat.
Packaging:
25 kg bag
42 bags/pallet
FLÄCHENDICHTBAND is a
12 cm-wide, stretchy polyester
fabric with an integrated
7 cm-wide, elastic, grained,
blue central strip providing a
waterproof coating.
MULTI-FINISH M is a machineapplied filling compound and
is exclusively applied using the
Easyputz
Packaging:
20 kg pail
24 pails/pallet
14 _ 15
Product range
Product range
Interior walls + Interior ceilings
Metal profiles – walls
Priming of Gypsum Board
Corrosion-resistant metal profiles and accessories
Tiefengrund
Knauf Wetroom Solutions with AQUAPANEL® Technology Inside are
constructed with a corrosion-resistant metal framework. Knauf offers
a full range of profiles and geometries to suit all applications. Knauf
metal profiles are precision-engineered, high-quality steel sections.
Tiefengrund is a smooth
water-based dispersion of
synthetic resins which is used to
improve adhesion of finishing
layers such as paint, plaster or
tile adhesive for tiling. It is the
standard primer for regular
absorbent substrates.
Packaging:
15 l pail
24 pails/pallet
C and CW profiles
Spezialgrund
Spezialgrund is a mineralfilled, white pigmented synthetic
dispersion which is used to
improve adhesion of finishing
layers such as paint, plaster or tile
adhesive for tiling. It is formulated
For standard applications, profiles from 0.6 mm to 1 mm
thickness are sufficient
Profiles of 1 mm or higher thickness should be used for
higher demands
for smooth and porous surfaces
(i.e. non absorbent and strongly
absorbent substrates. When
smoothed, it creates a surface
finishing without visible pores.
Packaging:
20 l pail
24 pails/pallet
For vertical placement between UW profile rails of substructures
for Knauf Wetroom Solutions
Corrosion-resistant
Can also be used for exterior constructions.
UW profiles
Putzgrund
Putzgrund is a synthetic resin
dispersion filled with fine quartz
sand, white pigmented and
alkali-resistant. It is used for
interior priming on Gypsum
Boards before plastering and
pre-treatment of absorbent and
non-absorbent substrates.
Packaging:
20 l pail
24 pails/pallet
Horizontal profile rails for floor and ceiling to place C and CW
profiles of substructures for Knauf Wetroom Solutions
Corrosion-resistant
Can also be used for exterior constructions.
UA profiles and angle connections
Higher thickness profiles
For vertical placement between UW profile rails of substructures
for Knauf Wetroom Solutions
For higher statics and loading requirements
Corrosion-resistant
Can also be used for exterior constructions.
16 _ 17
Product range
Product range
Metal profiles – walls
Metal profiles – ceilings
Hat profiles
Profiles
For direct application on existing surface
For renovation projects
For constructions with limited space requirements.
Illustrator grid gebruiken
1 omhoog = 2 naar rechts
CD
60/27
Ceiling substructure as support and basic profile
For interior and exterior ceilings
Corrosion resistant
Connected with cross connectors
UA profiles and angle connections
as base section
Additional profiles
To reinforce corners
For curved wall applications;
for interior use.
Suspensions
a. Nonious Stirrup
b. Nonious Hanger Bottom
c. Direct suspension (Direktabhänger)
Decoupling Tape
Self-adhesive tape for decoupling
UW and CW profiles that are
connected to other building
elements (walls, columns,
ceilings) so that sound and
thermal bridges can be reduced.
Thickness: 3.2 mm
Width: 30/50/70/95 cm
Roll length: 30 m
a.
b.
c.
Connector
Cross connectors
For connection of basic and bearing profiles
18 _ 19
Product range
Processing/handling
Insulation
Glass mineral wool
Transportation and storage
Knauf Insulation glass mineral wool with ECOSE® Technology meets
the highest demands for thermal and sound insulation in buildings.
Insulating materials are made from naturally occurring and / or
recycled materials and bound with ECOSE® Technology, a binding
Knauf Insulation Partition Wall
Slab TP 115: MW EN 13162
T4-WS-WL(P)-AFr5
agent, free of formaldehyde, phenol and acrylic. They are noncombustible, diffusion-open and resistant to aging. Thanks to their
compaction and low weight they are easy to lift and transport. Knauf
Insulation glass wool conforms to EN 13162 standard.
Knauf Insulation Partition Wall
Slab TW: MW EN 13162
T4-WS-WL(P)-AF10
Knauf Insulation Partition Wall
Roll TI 140 T: MW EN 13162
T2-AF5
Covered with black-coloured
glass mat on one side.
Covered with light-coloured
glass mat on one side.
Boards
Profiles
Always carry the boards upright,
or use board rollers. Handle with
fork lift or crane as palletted
goods. Take care not to damage
corners and edges when setting
the boards down! Place boards
down on their long edge before
laying them flat.
Protect profiles from moisture
and weathering before they are
installed. Products should not be
left permanently exposed to the
elements.
Use a pallet to support the
boards when using mechanical
handling equipment. Ensure that
the base is strong enough to
support the boards.
Protect boards from moisture
and weathering before they are
installed. Boards which have
become damp must be dried on
both sides on a flat surface prior
to fitting.
Stone mineral wool
Knauf Insulation stone mineral wool insulation materials meet the
highest demands for thermal, sound and fire protection in buildings.
Insulating materials are non-combustible and resistant to deformation
and aging. Stone wool insulation materials are heavier than glass
wool insulation products due to the higher dry density. Knauf
Insulation mineral wool conforms to EN 13162 standard.
Before installing, condition
the boards to the ambient
temperature and humidity. The
ambient air and component
temperatures may not be below
+5°C. Do not apply joint fillers,
basecoat or finishing materials
in temperatures less than +5°C.
KD 035 Core insulating board:
MW EN 13162 T4-WL(P)
KP 035 Clamping board:
MW EN 13162 T4-AF5
DPF 50 Fire insulating board:
MW EN 13162 T4-AF5
FPL 035 Fire insulating board:
MW EN 13162 T4-AF5
Insulation
Insulation materials are supplied
enclosed in polythene which is
designed for short term protection
only. For longer term protection
on site, the product should be
stored either indoors, or under
cover and off the ground.
Installation instructions are on
every pack. Products should not
be left permanently exposed to
the elements.
Health and safety
Observe the recommendations regarding the handling and storage of
materials given earlier in this section. Consult the appropriate product
data sheets and material safety data sheets. In addition the following
notes are offered for guidance:
Avoid unnecessary dust on job site when using electrical saw.
Keep sanding and other dust generation to a minimum. Maintain
adequate ventilation and/or wear suitable protection.
Exercise care when using power tools and take all necessary
precautions.
Follow instructions on packaging when applying system accessories.
When using powdered products, mix with water in well-ventilated
conditions. Avoid contact with eyes and skin. In the event of contact
with the eyes, irrigate with plenty of clean water immediately.
When handling insulation or cutting boards which contain
glass-fibre, wear suitable protection including face mask and
gloves. Wear protective glasses when working overhead.
Follow national health and safety regulations at all times.
A full range of product and safety information sheets are available
upon request.
20 _ 21
Installation of Knauf Wetroom Solutions with
AQUAPANEL® Technology Inside
Processing/handling
Installation of Interior Walls
Formatting/cut-outs
Boards
Profiles
1. Create substructure
Mark the desired shape or
opening on the board with pencil
and ruler. Use a knife to score the
board on one side along the line
so that the mesh or thick paper is
cut. Snap the scored edge and cut
the mesh/paper on the rear side.
Cut profiles up to 0.7 mm
thickness using manual or
electrical scissors or use an
electrical circular saw with special
metal blade. When cutting
corrosion-resistant profiles, make
sure the cut edges are recoated
with appropriate material.
1.1 AQUAPANEL® Cement
Board Indoor can be mounted
on a wall framework made from
either metal or wooden profiles.
For sharp-edged cuts, for
example, exterior edges, use a
hand-held circular saw with a
dust extractor or a pendulum
jigsaw. Use of a carbide or
diamond-tipped saw blade is
recommended.
To make cut-outs for wiring and
pipes, use a jigsaw or keyhole
saw. The diameter of the opening
should be approximately 10 mm
greater than the diameter of the
pipe. The remaining gap can be
closed with a cuff, suitable
sealant or sealing strip.
Metal thicknesses bigger than
0.7 mm cannot be cut by scissors.
Electric separating tools need to
be used. The tool has to be
selected according to the coating
system. This is especially important
for lacquers and other organic
coatings, which are damaged by
the influence of temperature and
flying sparks. The use of a band
saw is highly recommended.
For special cut-outs e.g. for
pipes, services, only use special
pre-fabricated slots as available
in the profiles.
1.2 The connection profile on
either side must be coated with
partition wall putty or sealing
tape. Rotary pin dowels or other
­fasteners are used to secure the
profiles to the walls.
Screw spacing ≤ 250 mm.
Spacing from edge ≥ 15 mm.
Screws should not be
overtightened.
Note: Please observe a gap of
3 – 5 mm between the boards.
1.3 Mark out the path of the
AQUAPANEL® Cement Board
­Indoor wall. All runners are
fastened to the floor and ceiling.
Profiles are cut to length and then
spaced 62.5 (60) cm apart. Set
and align these profiles with the
floor and ceiling profiles. Connect
the wall connection studs to the
end walls on either side.
2. Align the board
Align the first AQUAPANEL®
Cement Board Indoor panel
along the profiles. Ensure that
the board is aligned correctly
horizontally and vertically using
≥15 mm
≤250 mm
4. Clean the edge of the board
In order to ensure a good
­connection with AQUAPANEL®
Joint Adhesive (PU), clean the
edges of the board using, for
example, a wet brush.
Insulation
Insulation materials are easy
to handle and install, being
lightweight and easily cut to
size, where necessary using an
appropriate knife on flat surface
to cut. To minimise thermal
bridges insulation should fill
the complete stud spaces. Do
not use small pieces.
3. Fastening with screws
Fasten AQUAPANEL Cement
Board Indoor to the framework
with AQUAPANEL® Maxi Screws.
First fasten the screws into the
centre of the cement boards; then
work towards the ends and the
edges. During installation, make
sure the cement boards are
resting on the framework.
®
5. Apply the joint adhesive
5.1 Apply AQUAPANEL® Joint
Adhesive (PU).
22 _ 23
Installation of Knauf Wetroom Solutions with
AQUAPANEL® Technology Inside
Surface finishing
Installation of Interior Walls
Tiling
This must be done before the
next board is placed.
5.2 Insert AQUAPANEL® Cement
Board Indoor into the bed of
adhesive. Screw panel to the
framework. Joint reinforcement of
AQUAPANEL® Cement Board
Indoor panel is achieved by
means of the adhesion technique.
There is no need for the timeconsuming process of filling and
inserting joint tape.
5.3 AQUAPANEL® Joint
Adhesive (PU) must be applied
as a continuous bead along the
edges of the boards. Before
applying the adhesive, ensure that
the edges are cleaned using, for
example, a wet brush. It takes
approximately 50ml/m2 (40ml/m).
The tube contains enough
adhesive for approximately 6,5 m2.
7. Scraping off
Leave the adhesive to harden after
which the excess AQUAPANEL®
Joint Adhesive (PU) can be
scraped off (usually the next day).
Finishing
For ceramic tile coverings, (tile
dimensions ≤ 300 x 300 mm),
use a flexible adhesive when
placing tiles. The tile adhesive
must – as a minimum – meet the
requirements of class C2
according to EN 12004.
For a smooth finish, apply a thin
layer of AQUAPANEL® Joint
Filler & Skim Coating – white.
When dry, the surface can be
painted.
Note: Where single-layer
panels are required in tiling
applications, AQUAPANEL®
Cement Board Indoor is the
best tile backing board!
Finishing
Skim coating
8. Completed wall
The joints between the walls,
ceiling and floor require
permanent elastic sealing in
dry areas. Expansion joints
should be at a minimum of
7.5 (7.2) m intervals.
AQUAPANEL® Cement Board
Indoor can be prepared for
painting by coating it fully with
AQUAPANEL® Joint Filler &
Skim Coating – white (minimum
coating depth 4 mm).
Reinforcing
Apply AQUAPANEL® Reinforcing
Mesh and embed it in the skim
coat with a trowel.
6. Place next board
Install the next AQUAPANEL®
Cement Board Indoor panel and
ensure that the boards are
correctly aligned horizontally
and vertically. Screw panel to
the framework.
Boards
Painting
The majority of common
painting systems can be used.
These include water-based
emulsions, matt enamels,
polymer resin colours, and
epoxy-based enamels.
Alkyd enamels are not
compatible with the product.
For confirmation of usage,
please refer to the paint
manufacturers’ instructions.
A test coat is recommended.
For surface finishes up to Q4,
apply AQUAPANEL® Q4 Finish
over the entire pre-prepared
(filled and reinforced) surface.
After drying, do any re-finishing
with an electric orbital sander
(grade 120 or finer).
9. Priming
AQUAPANEL® Cement Board
Indoor must be primed before
tiling or finishing using
AQUAPANEL® Board Primer.
24 _ 25
Surface finishing
Finishing options
General
Coating above the tiled section up to Q4 quality
For fine finishing to a Q4 surface quality,
use AQUAPANEL® Q4 Finish ready-to-use skim coat.
Embedding glass fibre joint cover strips
Using a 15 cm wide stainless
steel finishing trowel, apply
AQUAPANEL® Q4 Finish to the
visible joints which have been
bonded with AQUAPANEL® Joint
Adhesive (PU). Embed the glass
fibre joint cover strips (e.g.
GLASS FIBRE JOINT COVER
STRIPS) into the centre of the
paste so that they overlap the
joints. Apply a thin layer of
AQUAPANEL® Q4 Finish to the
cover strips. Remove excess
­material.
Note: AQUAPANEL® Cement
Board Indoor is already glued
using AQUAPANEL® Joint
Adhesive (PU).
Embed fastener heads
Fill all screw heads. If necessary,
after drying, use a hand sander
to remove irregularities from the
screw holes.
Smoothing over joints and fasteners
Sand away all surface
unevenness. Apply AQUAPANEL®
Q4 Finish to a width of at least 20
cm (5 cm beyond the edge of the
first layer). Embed fastener heads
and sand down any uneven areas.
Surface finishing and quality levels
Gypsum Boards can be used with every conceivable surface
finishing but the quality of the finishing depends on the decorative
finish required as part of the contract and the skills of the dryliner.
When closing the joints on the plaster boards, it is possible to
achieve four quality levels.
Full surface skim coating
Apply AQUAPANEL® Q4 Finish
to completely cover the untiled
areas using a 20 cm wide
finishing trowel. Apply the filler
solidly to fill in uneven areas in
the joints and smooth the surface
texture. If necessary, sand down
with paper. If a Q4 surface
quality is required, apply a
further layer of AQUAPANEL®
Q4 Finish. After approx. 24
hours drying, sand with abrasive
paper (grade 120 or finer). For
particularly smooth surfaces,
sand down with, for example,
an electric orbital sander.
Coating
Depending on the intended use
and requirements, water emulsion
paints, emulsion silicate paints or
latex paints can be used.
Level of finishing
Q1
Q2 (Standard)
Q3
Q4
Jointed surface
Smooth surface for normal optical
requirements
Smooth surface for higher visual
requirements
Smooth surface for high visual
requirements
Aesthetic requirements
None
Normal
Enhanced. Few marks and traces
under direct light. Shading is still
possible under shallow light angles
High end. Minimised appearance
of any marks or traces. Shading
caused by shallow light angles
will be avoided to a large extent.
Application requirements
Joints and screw heads filled with
joint compound
Joints and screw heads filled,
finished to achieve a continuous
transition to the board surface,
sanded if necessary
Joints and screw heads filled,
finished (Q2), plus wide finish
trowelling and a sharp trowelled
full cover of the plaster board surface
(filling the paper pores), sanded if
necessary.
Joints and screw heads filled,
finished (Q2) plus a complete
surface covering skim coat of min
1 mm thickness, sanded if
necessary.
Finished surface suitability
Only suitable for functional
applications such as stability, fire
resistance and sound insulation.
E.g. filing joints of the first board
layer which is under tile coverings or
thick layered plasters.
Medium and coarse-structured wall
coverings, matt filling, medium
and coarse-structured paint coatings/
coats, top coats (particle size/
largest particle over 1 mm).
Fine-structured wall coverings, matt,
fine-structured paint coatings/coats,
top coats (largest particle size less
than 1 mm).
Smooth or glossy wall coverings,
e.g. metal-based or vinyl wallpapers,
scumbles, paints or coats up to
medium gloss, stucco marble or
similar specialist decorative finishes.
Flatness requirements
Refer to National standards
Note: The tiled section of the wall
should be > 50% of the total
height of the wall.
Not suitable for areas subject to
water spray!
Note: Priming the surface will depend on the selected interior finishing option. Quality level of surface finishing depends on the skills of the dryliner.
Quality classification according to leaflet no 2 “Skimming of Plaster
Boards – Surface Qualities” of the Plasterboard Industry Group
Association, which provides for four levels of quality.
26 _ 27
Interior finishing
Dry applications
Joint treatment: Gypsum Boards
In order to close the joints and to prepare the surface for the finishing
options the following materials can be used:
Uniflott: “The original”
for Q1– Q2 surface quality
tested and approved standard product
for manual use
Trias: “The efficient”
for Q1– Q2 surface quality
joints don‘t show due to carton-grey colour
good absorption behaviour
extremely low shrinkage when drying
tested and approved standard product
for manual use
Readygips: “The quickstarter”
ideal for Q1– Q4 quality
ready to use from the bucket and processing-friendly
full-surface joint compound to be used with Joint Tape Kurt
very easy to sand
very fine surface after drying
for manual and machine use
Multi-Finish / Multi-Finish M: “The noble”
ideal for Q4 quality
suitable for almost all subsurfaces
use for filling of uneven and rough surfaces
for manual and machine use
Joint Tape KURT
Joint Tape Kurt is a 50 mm wide strip of special
paper which is used to reinforce the joint filling
and edges of Gypsum Boards and Gypsum Fibre
Boards. Particulary resistant to tearing.
PUTZGRUND
Putzgrund is a synthetic resin dispersion filled with fine
quartz sand, white pigmented and alkali-resistant.
It is used for interior priming on Gypsum Boards
before plastering and pre-treatment of absorbent
and non-absorbent substrates.
28 _ 29
Interior finishing
Installation of Knauf Wetroom Solutions
Dry applications
Installation of Gypsum Boards
HRAK – semi-circular flattened longitudinal edge
Cut edge and develled/mixed joint
HRK – semi-circular longitudinal edge
TRIAS / Uniflott / Uniflott impregnated
1. Studs to be installed first
AFK – long side panel edge
2. Place insulation material
TRIAS / Uniflott / Uniflott impregnated
Use the right product for the job
depending on whether thermal
insulation, acoustic insulation or
fire protection is required. Cut
insulation to width /length with a
sharp long bladed knife.
The technically required surface – without optical requirements
TRIAS / Uniflott /
Uniflott impregnated
TRIAS / Uniflott /
Uniflott impregnated
+ Joint Tape KURT
3. Apply vapour barrier (if necessary)
For surfaces with conventional optical requirements
TRIAS / Uniflott /
Uniflott impregnated
TRIAS / Uniflott /
Uniflott impregnated
+ Joint Tape KURT
For surfaces with higher optical requirements
TRIAS / Uniflott /
Uniflott impregnated
Readygips
TRIAS / Uniflott /
Uniflott impregnated
+ Joint Tape KURT
Readygips
Make sure all electrical installation
has been completed. To ensure air
tightness of building construction,
apply vapour barrier to the inside
if specified in building physical
calculation.
TRIAS / Uniflott /
Uniflott impregnated
Readygips or Putzgrund
and Multi-Finish /
Multi-Finish M
Where services penetrate the
building elements, ensure that the
penetrations are sealed in order to
obtain optimum air tightness.
Note on interior finishing
(dry applications only)
Screw Gypsum Boards to
substructure using Drywall
Screws (TN3.5/35).
TRIAS / Uniflott /
Uniflott impregnated
+ Joint Tape KURT
Readygips or Putzgrund
and Multi-Finish /
Multi-Finish M
Run the trowel progressively down
the joint applying sufficient
pressure to squeeze out entrapped
air. Allow the joint filler to set for
approx. 1 hour. If required, sand
lightly to remove any high spots.
Remove surface dust.
Allow the joint filler to set for
approx. 1 hour. If required, sand
lightly to remove any high spots.
Remove surface dust.
4. Install Gypsum Board (dry applications only)
For surfaces with highest optical requirements
Fill joints (e.g. standard Gypsum
Board application with HRAK
edge). Use trowel to fill joints
with suitable joint filler (Uniflott).
For double layer system, the
joints of the first layer of board
must also be filled before placing
the second layer of boards.
Apply an additional thinner
layer of joint filler and remove
any surplus filler. Feather out
application beyond the joints
– approximately 100 to 200 mm.
Where the wall construction
includes a double layer of
Gypsum Board, the vapour barrier
can be placed between the two
layers for fast easy installation.
The vapour barrier must overlap
where more than 1 layer is
placed. It must also overlap when
applied at connections to other
building elements. Use suitable
glue and tapes.
5. Joint treatment (dry applications only)
Once joints have been filled and after drying, if finishing is not satisfactory,
use trowel to apply a tight coat of Uniflott joint filler. Feather out beyond
previous application of material. Allow the joint treatment to set. Lightly
sand to remove any minor imperfections and create a smooth surface.
If required, apply a final coat of Finish-pastös and feather out beyond
previous application. Lightly sand to remove minor imperfections.
Remove surface dust.
Note: Priming the surface will depend on the selected interior
finishing option.
See section Interior finishing for more details.
30 _ 31
Interior finishing options
Choose the perfect surface finishing
Ceramic tiles Q1
Ñ
Q3
1. AQUAPANEL® Cement Board Indoor
2. AQUAPANEL® Maxi Screw
3. AQUAPANEL® Joint Adhesive (PU)
4. AQUAPANEL® Board Primer
5. Knauf Tile Adhesive
6. Ceramic tiles
Ç
Ö
Wallpaper finish É
É Ä
Ç
Ä
Å
Å
Decorative plaster finish
Q2
Paint finish Q4
1. Knauf Gypsum Board with HRAK edge
2. Knauf Drywall Screws
3. Knauf Uniflott
4. Knauf Tiefengrund
5. Knauf Easyputz
Ñ
É
1. K
nauf Gypsum Board with HRAK edge
2. K
nauf Drywall Screws
3. Knauf Uniflott
4. Knauf Tiefengrund
5. Wallpaper
Ñ
Ñ
1. AQUAPANEL® Cement Board Indoor
2. AQUAPANEL® Maxi Screw
3. AQUAPANEL® Joint Adhesive (PU)
4. AQUAPANEL® Board Primer
5. Glassfibre Joint Covering Strip
6. AQUAPANEL® Q4 Finish
Ç
Ö
É
Ç
Ä
Å
Ö
Level of finishing
Ä
Å
Ö
Q1
Q2 (Standard)
Q3
Q4
Jointed surface
Smooth surface for normal optical
requirements.
Smooth surface for higher visual
requirements.
Smooth surface for high visual
requirements.
32 _ 33
Installation details
Curved interior walls
Knauf Metal Stud Partitions
Gypsum Boards
Inside Arch - Concave
Outside Arch - Convex
Board
thickness
Knauf Metal Stud Partitions
Length of layout L
W11
ed
ss
e
sid
ed
ed
e
ss
sid
e
e
ed
ss
sid
sid
ss
Gypsum Board should be bent wet. Evenly spray water on the surface
so that the water is allowed to soak into the core before application.
The board must be dried within 24 hours of wetting to prevent the
development of mould. Fans and mechanical dehumidifiers should
be used to accelerate drying when conditions are not conducive to
natural drying. When the Gypsum Board dries thoroughly, its original
hardness is regained.
channels or similar with the side to be compressed on top and
α the
= 90°
180°
excessing theAngle
grid on
perimeters (so excessAngle
waterα
can= drip
off).
batten to
fix the
board
Wet bending
a few minutes.
Repeaton
process
water drains.
1. Put the cut-to-length
Knauf Boards
a grid until
madeexcessive
of
channels4.or similar
withon
theprecast
side to
bePcompressed
onwith
top and
Lay board
device,
fix
tape Gypsum
1.molding
ut the
cut-to-length
excessing theand
gridletonit dry.
the perimeters (so excess water can drip off).
Boards on a grid made of channels
or similar with the side to be compressed on top and excessing
2. Perforate the board laterally and longitudinally with Spike Roller.
the grid on the perimeters (so excess water can drip off).
3. Wet the board by spraying or with lambskin roller and let it settle for
2. excessive
Perforate
the
board laterally and longitudinally with spike roller.
a few minutes. Repeat process until
water
drains.
4. Lay board on precast molding device,
withthe
tapeboard by spraying or with lambskin roller and let it settle
3. W
fixet
and let it dry.
for a few minutes. Repeat process until excessive water drains.
Bending device
deviceon precast moulding device, fix with tape and
4. molding
L ay board
angle or CD Channel
let it dry.
to support boards
length of layout
longitudinal direction
length of layout
longitudinal direction
Wet bending
3. Wet the board by spraying or with lambskin roller and let it settle for
batten
to fix the
board
batten
to fix the
board
Knauf Board strip
to support
cut board
molding deviceAngle or CD profile
Detail scale 1:5
device
Inside arch –molding
concave,
outside
AQUAPANEL Cement Board Indoor
Detail scale 1:5
to support boards
Knauf Board strip
cut board
arch – convex
d � 12.5 mm
UW Runner
75x40x0.6
Dry bending
1. Bend Knauf Boards over metal grid or frame.
Dry bending
the board
d � 12.5 mm
Board strips; cutted
Boardangle
thickness
12.5 mm
or CD≥Channel
®
All angles up to α = 180°
2. Perforate the board laterally and longitudinally with Spike Roller.
length of layout
longitudinal direction
Biegeanleitung
wet bending
wet bending
Board size: 1200/2400/1250/
2500 x 900 mm
Minimum bending radius ≥ 3 m
Strip size: 1200/2400/1250/
2500 x 300 mm
Minimum bending radius ≥ 1 m
Max. stud spacing: ≤ 300/312.5
mm (external radius)
Bending radius r
dry
wet
angle
90° r of Gypsum Boards
Board thickness
Bending
radius
d
d
bending
bending
r.
L= 2
mm
mm
mm
Bent Partitionsbwith
75x40x0.6
at Web
d mm Pre-punched Dry
bending mm
Wet bending mm
e c om Bent Knauf Boards and UW Runners
6.5 (Mold Board) � 1000
� 300
angle
180°
t o c e s i pr e
.
r
f a r de
6.5
≥
1000
≥ 300
L
=
9.5 Bending radius
� 2000 r � 500
Inside Arch - Concave Outside Arch - Convex
Length of layoutr L
to
r e Board
b e c o m p thickness12.5
� 2750
� 1000
all
angles
up
to
180°
9.5
≥ 2000
≥ 500
dry
wet
. r.
angle
90°
f a
c e ds i d e d
d
bendingbending
bending
r . L = 180
longitudinal
only
L
=
mm
mm
mm
12.5
≥ 2750
≥ 1000
2
b e c om p r
6.5 (Mold Board) � 1000
� 300
angleonly 180°
t oBiegeanleitung
e
s
e
Longitudinal
bending
i
c
d
Inside arch f–a concave,
outside arch – convex
r
L = r.
9.5
� 2000
� 500
r e
to
re
b e c omp
Wet
bending� 1000
12.5
� 2750
all angles up to 180°
. r.
f a
c e s i de
d
L =Lon a grid
1.
Put
the
cut-to-length
Knauf
Boards
made of
longitudinal bending only Length of layout
180
Gypsum Board may be used to form almost any cylindrically curved
surface. To prevent flat spots on the curved surface, profiles must be
spaced more closely together than required for typical flat wall or
ceiling surfaces.
For applications such as arches
AQUAPANEL® Cement Board
Indoor can be curved. Using
metal shears, cut the UW-profile.
Fit the UW-profile to the desired
radius. Crimp the CW-profile to
the perforated UW-profile.
Before installation, bend the
cement board panel. The fine
cracks that occur on the board
surface will not cause any loss
of performance.
W11
Partitions
withconstruction
Bent Knauf Boards and UW Runners 75x40x0.6 Pre-punched at Web
CurvedBent
interior
wall
2. Fix with Drywall
Screws
following the bending continuously.
molding
device
Dry bending
1. B
end Gypsum Boards over metal grid or frame.
2. F ix with Drywall Screws following the bending continuously.
1. Bend Knauf
Boards over metal grid or frame.
Assembly
2. Fix with Drywall
Screws flange
following
the bending
1. cut outside
at web
punchescontinuously.
2. bend UW Runners to required radius
Knauf
CW Stud
75x50x0.6
3. connect Knauf CW Studs to pre-punched UW Runners by crimping
Assembly4.
cladding lateral
Assembly
spacing
CW Studs:
� 312.5 mm (outside radius)
1. cut outside
flange atKnauf
web punches
Plug:
� 300
mm punches.
1. Cutradius
outside flange
at web
2. bend UWspacing
Runners toNailable
required
Knauf
UW profile
UW
Runner
75x40x0.6 UW Runner 75x40x0.6
pre-punched at web
Knauf
(Mat. no. 00003387)
CW Stud
75x50x0.6
radius.
3. Connect CW profiles to pre-punched UW profiles by crimping.
Drywall Screw TN
4. Cladding
lateral.
spacing Knauf CW Studs:
� 312.5
mm (outside radius)
Knauf
sinus flexible
UW
Runner
75x40x0.6
U-connection profile
spacing Nailable Plug:Spacing CW
� 300profiles:
mm
pre-punched at web
≤ 312.5 mm (outside radius)
e.g. Knauf Mold Boards
(Mat. no. 00003387)
Spacing anchor: ≤ 300 mm
2x 6.5 mm
_ 3m
r: >
2.toBpre-punched
end UW UW
profiles
3. connect Knauf CW Studs
Runnerstobyrequired
crimping
4. cladding lateral
Nailable Plug
Knauf Drywall
Drywall
Screw Screw
TN
UW Runner
75x40x0.6
Knauf Uniflott +
Joint Tape
e.g. Knauf
Knauf Gypsum
Board
e.g.
Mold Boards
2x 6.5 mm
Nailable Plug
W111-SO1
Bent Partition
UW Runner
Knauf
UW profile
75x40x0.6
KnaufUNIFLOTT
Uniflott ++
Knauf
Knauf JointJoint
Tape Tape
KURT
21
W111-SO1
Bent Partition
Inside arch – concave, outside arch – convex
21
34 _ 35
spachtel - grau geschlossen und
das AQUAPANEL® Fugenband in
die Spachtelmasse eingearbeitet.
Die Schraubenköpfe werden
ebenfalls verspachtelt.
Installation of ceilings
Nach Erhärtung wird die Fläche
mit AQUAPANEL® Grundierung
– innen grundiert (Grundierung /
Wasser 1:2).
Montage
Montage von
von Decken
Decken
Variant 1 1
Variante
Variante
Variante 1
1
Variant 2
The following
minimum spacings
Bei
Bei der
der Unterkonstruktion
Unterkonstruktion
Bei
der
Unterkonstruktion
are
required
for
the framework:
Bei
der
Unterkonstruktion
werden mindestens
werden
mindestens folgende
folgende
werden
mindestens
folgende
Hanger
werden
mindestens
folgende
Abstände vorausgesetzt:
vorausgesetzt:
Abstände
Abstände
vorausgesetzt:
a
=
750
mm
Abstände
vorausgesetzt:
Abhänger
Abhänger
Abhänger
section CD 60/27/06
Abhänger
aaSupport
=
= 750
750 mm
mm
aaTragprofil
b=
450mm
mm 60/27/06
==750
750
mm
Tragprofil CD
CD 60/27/06
Tragprofil
CD
60/27/06
Base
section
60/27/06
Tragprofil
CDCD
60/27/06
b
b=
= 450
450 mm
mm
c
=
1000
mm
b
=
450
mm
b
=
450
mm
Grundprofil
Grundprofil CD
CD 60/27/06
60/27/06
Grundprofil
CD
Grundprofil
CD 60/27/06
60/27/06
cc =
1000
mm
= 1000 mm
cc =
= 1000
1000 mm
mm
Once the primer has dried,
Align the Platte
first cement entlang
board
Die
Die erste
erste Platte wird
wird entlang der
der
panel
carefully
along
the lath,der
Die
erste
Platte
wird
entlang
Die erste Platte
wird entlang
der
Traglattung
Traglattung (quer
(quer zur
zur GrundGrundperpendicular
to the
batten.
Traglattung
(quer
zur
GrundTraglattung
(quer
zur
Grundlattung)
sorgfältig
ausgerichtet.
lattung)
sorgfältig ausgerichtet.
®
Using AQUAPANEL
Maxi
lattung)
sorgfältig
lattung)
sorgfältig ausgerichtet.
ausgerichtet.
Mit
den
Maxi
Mit
den AQUAPANEL®
AQUAPANEL®
Maxi ®
screws,
screw the AQUAPANEL
Mit
den
Maxi
Mit
den AQUAPANEL®
AQUAPANEL®
Maxi
Schrauben
werden
die
Schrauben
werden
die
Cement
Board
Indoor
panel
Schrauben
werden
die
Schrauben
werden
die Boardto
AQUAPANEL®
Cement
AQUAPANEL®
Cement
Boardof
the framework,Cement
with spacing
AQUAPANEL®
Board
AQUAPANEL®
Cement
Board
Indoor
in
einem
Abstand
von
a
Indoor
in
einem
Abstand
von
2
a
=
170
mm
(22
pieces/m
). a
Indoor
in
einem
Abstand
von
aa
2
Indoor
in einem
Abstand
von
=
170
mm
(22
Stück/m
die
2) an
= 170 mm (22 Stück/m22) an die
=
170
mm
(22
Stück/m
)
an
die
=
170 mm (22 Stück/m ) an die
Unterkonstruktion
Unterkonstruktion geschraubt.
geschraubt.
Unterkonstruktion
Unterkonstruktion geschraubt.
geschraubt.
Die
folgenden
Platten
werden
Die
folgenden
Leave
a gap ofPlatten
at least werden
3-4 mm
Die
folgenden
Platten
werden
Die
folgenden
Platten
werden
mit
ca.
3
–
4
mm
Fuge
im Vermit
ca. 3 joints
– 4 mm
Verbetween
andFuge
makeim
all
mit
ca.
3
–
4
mm
Fuge
Vermit
ca.montiert,
3 – 4 mmKreuzfugen
Fuge im
imsure
Verbund
sind
bund
montiert,
Kreuzfugen
joints montiert,
are staggered.
After sind
bund
Kreuzfugen
sind
bund
montiert,Die
Kreuzfugen
sind
nicht
zulässig.
Fugen
werden
nicht
zulässig.
Dieshould
Fugenbe
werden
installation,
joints
filled
nicht
zulässig.
Die
werden
nicht
zulässig.
Die Fugen
FugenFugenwerden
mit
dem
AQUAPANEL®
mit
demAQUAPANEL
AQUAPANEL®
Fugen®
in with
Joint
Filler
mit
dem
Fugenmit
dem AQUAPANEL®
AQUAPANEL®
Fugenspachtel
-- grau
geschlossen
und
spachtel
grau
geschlossen
und
®
– grey with
AQUAPANEL
Tape
spachtel
grau
geschlossen
und
spachtel
- grau geschlossen
und
das
AQUAPANEL®
Fugenband
in
das
AQUAPANEL®
Fugenband
embedded
into
the
filler.
Also
fillin
das
AQUAPANEL®
in
das
AQUAPANEL® Fugenband
Fugenband
in
die
Spachtelmasse
einge
arbeitet.
die
Spachtelmasse
arbeitet.
all screw
heads. einge
die
Spachtelmasse
einge
arbeitet.
die
Spachtelmasse
einge
arbeitet.
Die
Schraubenköpfe
werden
Die Schraubenköpfe werden
Die
Schraubenköpfe
Die
Schraubenköpfe werden
werden
ebenfalls
ebenfalls verspachtelt.
verspachtelt.
ebenfalls
ebenfalls verspachtelt.
verspachtelt.
Nach
Erhärtung
die
Nach
Erhärtung wird
wird
dietheFläche
Fläche
After hardening,
prime
Nach
Erhärtung
wird
die
Nach
Erhärtung
wird
die Fläche
Fläche®
mit AQUAPANEL®
AQUAPANEL® Grundierung
Grundierung
mit
surface
over using AQUAPANEL
mit
AQUAPANEL®
Grundierung
mit
AQUAPANEL®
Grundierung
innen grundiert
grundiert (Grundierung
(Grundierung //
––Board
innen
Primer (primer/water
1.2)
––Wasser
innen
(Grundierung
innen grundiert
grundiert
(Grundierung //
1:2).
Wasser 1:2).
Wasser
Wasser 1:2).
1:2).
AQUAPANEL®
AQUAPANEL® Q4
Q4 –– Finish
Finish
AQUAPANEL®
Q4
AQUAPANEL®
Q4 –– Finish
Finish
kann
nun
nach
kann nun nach Trocknung
Trocknung der
der
kann
nun
nach
Trocknung
der
kann
nun nach Trocknung
der
Grundierung
Grundierung vollflächig
vollflächig und
und ohne
ohne
Grundierung
vollflächig
und
Grundierung
vollflächig
und ohne
ohne
Gewebearmierung
aufgetragen
Gewebearmierung aufgetragen
Gewebearmierung
aufgetragen
Gewebearmierung
aufgetragen
werden.
Der
Auftrag
in
einem
werden. Der Auftrag in einem
werden.
Der
werden.
Der Auftrag
Auftrag in
in einem
einem
Arbeitsgang
Arbeitsgang beträgt
beträgt max.
max. 2
2 mm.
mm.
Arbeitsgang
beträgt
max.
2
Arbeitsgang
beträgt max.
2 mm.
mm.
Nach
der
Trocknung
ist
die
Nach der Trocknung ist die OberOberNach
Trocknung
ist
Nach der
der
Trocknung(Schleifpapier
ist die
die OberOberfläche
zu
schleifen
fläche zu schleifen (Schleifpapier
fläche
zu
fläche
zu schleifen
schleifen (Schleifpapier
(Schleifpapier
120
120 oder
oder feiner).
feiner). Ggf.
Ggf. ist
ist ein
ein zweizwei120
oder
feiner).
ist
120
oder feiner). Ggf.
Ggf.erforderlich.
ist ein
ein zweizweiter
Spachtelvorgang
ter Spachtelvorgang erforderlich.
ter
Spachtelvorgang
erforderlich.
ter
Spachtelvorgang
erforderlich.
Mit
AQUAPANEL®
Q4
–
Finish
Mit AQUAPANEL® Q4 – Finish
Mit
Mit AQUAPANEL®
AQUAPANEL® Q4
Q4 –– Finish
Finish
14
Alternativ:
Alternativ: ® Q4 – Finish
AQUAPANEL®
Alternativ:
AQUAPANEL
Q4 FinishArbeitscan
Alternativ:
Über
die
beschriebene
Übernun
die nach
beschriebene
Arbeitskann
Trocknung
der
Über
die
beschriebene
Arbeitsbe
applied
to
the
entire
surface
Über
die
beschriebene
Arbeitsweise
ist
weise hinaus
hinausvollflächig
ist ein
ein Verkleben
Verkleben
Grundierung
und
ohne
weise
hinaus
ist ein
eininVerkleben
Verkleben
without
any reinforcing.
No more
weise
hinaus
ist
der
der Plattenkanten
Plattenkantenaufgetragen
in der
der DeckenDeckenGewebearmierung
der
Plattenkanten
inisder
der
Deckenthan
2mm of coating
applied
der
Plattenkanten
in
Deckenanwendung
möglich.
Unteranwendung
möglich.inDie
Die
Unterwerden.
Der Auftrag
einem
anwendung
möglich.
Die
Unterinanwendung
a
single
step.
Once
the
finish
möglich.
Die
Unterkonstruktion
und
Plattenrichtung
konstruktion
und Plattenrichtung
Arbeitsgang
beträgt
max. 2 mm.
konstruktion
und
Plattenrichtung
has
dried,
sand
the
surface
(using
konstruktion
und
Plattenrichtung
ist
Variante
auszuführen.
ist wie
wie
inTrocknung
Variante 11 ist
auszuführen.
Nach
derin
die Oberist
wie
insandpaper
Variante
auszuführen.
120-grit
finer).
ist
wie
in
Variante
11orauszuführen.
Die
Montage
ist
wie
im
Die Montage
ist wie
im WandWandfläche
zu
schleifen
(Schleifpapier
ADie
second
coat ist
of finish
may
be
Montage
wie
WandDie
Montage
ist
wie im
im
Wandbereich
vorzunehmen.
Dehnfugen
bereich
vorzunehmen.
Dehnfugen
120
oder
feiner).
Ggf.
ist
® ein zweirequired.
AQUAPANEL
Q4
bereich
vorzunehmen.
Dehnfugen
bereich
vorzunehmen.
Dehnfugen
sind
alle
sind
alle 7,5
7,5 m
m anzuordnen.
anzuordnen.
ter
Spachtelvorgang
erforderlich.
Finish
achieves
finish of up to
sind
alle
7,5 m
m aanzuordnen.
anzuordnen.
sind
alle
7,5
Mit
AQUAPANEL®
Q4
– Finish
Q4
surfaceInnenwände
quality. Please see
the
Montage
Montage
Innenwände s.
s. S.
S. 9
9 ff.
ff.
kann
eine
Oberflächenqualität
specific
instructions
on
page
15.
Montage
Innenwände
s.
S.
9
Montage Innenwände s. S. 9 ff.
ff.
bis Q4 erreicht werden.
Bitte beachten Sie die besonderen
Hinweise auf Seite 15.
Align the first AQUAPANEL®
Cement Board Indoor panel
carefully, perpendicular to the
supporting profile. Screw the
panel to the framework using
AQUAPANEL® Maxi Screws
(material requirement 25 pcs/
m2). The centre space between
the supporting profiles is
300/312.5 mm.
Alternative
Filler – grey with the 10 cm
wide AQUAPANEL® Tape
embedded into the filler. Fill
all screw heads.
AQUAPANEL1 Cement Board Indoor
As an alternative to the method
described here, the edges of the
board panel can be glued into
the ceiling application. The
framework and boards should be
arranged and positioned as
shown in Variant 1. To assemble,
proceed as for a wall installation.
Expansion joints should be
installed at 7.5 m intervals.
Leave a gap between joints of
at least 3-4 mm. Make sure all
joints are staggered. After
installation, joints should be
filled in with AQUAPANEL® Joint
Prime the surface over using
AQUAPANEL® Board Primer
(primer/water 1.2).
Special notes
In rooms with continuous high
humidity levels such as commercial
kitchens, swimming pools, saunas
or chemical laboratories, it is
necessary to provide improved
corrosion protection for the
metal framework.
When cutting AQUAPANEL®
Cement Board Indoor, the
distance of the screws from the
board edge must be ≥ 15 mm.
The distance between screws
must be ≤ 250 mm.
Fasten the hanger of the
framework with suitable, building
authority approved ceiling pins
e.g. Type KDM Kunkel ceiling pin
or MKT anchor bolt B6 material
1.4529.
We recommend that expansion
joints are included at maximum
15 m intervals. Align with
the expansion joints in the
background if practical.
Use AQUAPANEL® Joint Filler &
Skim Coating – white to coat the
panels to at least 4 mm depth
all-over, and embed the
AQUAPANEL® Reinforcing Mesh.
For fine finishing up to Q4
surface quality, use
AQUAPANEL® Q4 Finish on
AQUAPANEL® Joint Filler &
Skim Coating – white.
36 _ 37
Permitted console loads
Construction details
Permitted console loads
Wall hooks
Light partition walls built with AQUAPANEL® Cement Board ­Indoor
can accept console loads of different sizes. Should loads be inserted
in double-layer walls, the stud rows must be connected together using
consoles to ensure tensile strength. The size and geometry of the load
must be monitored for all walls. A deciding size is the “load height“,
i.e. the distance of the load outer edge from the wall or the height of
a hanging shelf or hanging cabinet. The following cases can be
distinguished depending on the size and height of the load:
Light console loads up to 40 kg/metre wall length
Light console loads can be arranged on any position of the wall or
facing panel. If the load is attached to the panel, the distance of the
fastening points from each other must be at least 75 mm. Loads of up to
40 kg per metre wall length at a load height of 60 cm are considered
light console loads. Loads can be increased if the load height is low.
5 kg
10
20
30
40
50
60
Permissible console load P
(kg/metre wall length)
78
71
63
55
48
40
15 kg
Hooks for light, flat objects up to 15 kg/m
Plastic cavity wall plugs
Metal cavity wall plugs
Light and other bracket loads up to 70kg/m
Wall hooks
Flat loads
Loads up to 15 kg can be secured using simple hooks. Flat loads
up to 50 kg are fastened using metal or plastic cavity wall plugs.
Maximum size “light console loads” as a function of load depth b
Load depth (cm)
10 kg
Light and other bracket loads
Light and other bracket loads are secured using at least two
plastic or metal cavity wall plugs. Plugs should be spaced more
than 75 mm apart. See table.
Plug load-bearing capacity (kg) under pull and shear
Other console loads of 40 to 70 kg/metre wall length
Other console loads can be attached in any position on a ­single or
double stud installation with double-layer panelling of AQUAPANEL®
Cement Board Indoor. With double stud walls, the stud rows must be
fixed with consoles to ensure tensile strength. Loads of between 40
and 70 kg per metre wall length at a load height of 60 cm are
considered medium console loads. Loads can be increased if the
load height is low.
Light console loads
Panel thickness (mm)
Plastic cavity wall plugs
Ø8
Ø 10 mm
Metal cavity wall plug
M5 or M6 screw
Knauf
Hartmut
1 x 12.5
30 kg
40 kg
30 kg
60 kg
2 x 12.5
40 kg
70 kg
50 kg
110 kg
Ceiling hooks
Maximum size “other console loads” as a function of load depth b
Load depth (cm)
10
20
30
40
50
60
Permissible console load P
(kg/metre wall length)
107
100
93
85
78
70
Heavy console loads of 70 to 150 kg/metre wall length
Heavy console loads must be attached to special construction parts
such as cross beams, console frames or cross member ­bracing. Cross
beams and cross member bracings are directly linked to the framework
so that the loads can be securely taken into the framework. Supporting
frames are fastened to the ­framework depending on the type of
construction but are generally anchored directly to the original floor.
Tilting ceiling hooks
Spring toggle ceiling hooks
Securing loads to suspended ceilings
Other console loads
Light loads, which do not exceed the load-bearing capacity of a light
suspended ceiling, may be fastened to the panel. Heavier loads must
be secured separately to the original ceiling. Tilting ceiling hooks or
spring toggle ceiling hooks should be used to fix these.
The maximum possible load capacity depends on the individual ceiling
construction. The maximum load-bearing capacity of the ceiling hooks
is 20 kg in single-layer panelling and 25 kg in double-layer panelling.
38 _ 39
AQUAPANEL® special fittings
AQUAPANEL® Traverse
AQUAPANEL® Access Door
Access Doors comprising aluminium frame with AQUAPANEL® Cement
Board Indoor infill which can be used in interior partition walls and
suspended ceilings. For use in splash water areas as well as in humid
rooms. Both access doors are available in a range of sizes and are
fitted with corrosion-resistant profiles and hinges, multiple purpose for
wall and ceiling. Doors come with AQUAPANEL® Maxi Screw SB 39
and are available with key locking system on request.
Handling & installation
Application
Fix in place avoiding any distortion. Align the closing system towards
the ceiling. Screw the outer frame to the wall substructure and adjust
and secure the inside cover safety hinges. Then place the inner cover in
position, check that it functions properly, and finish the wall panelling.
AQUAPANEL Access Doors can be installed in partition and solid
walls and ceilings built with AQUAPANEL® Cement Board Indoor.
They are easy to install and safe to handle. Walls lined with
AQUAPANEL® Cement Board Indoor and with AQUAPANEL® Access
®
I. Attach using crimping pliers
M type traverse
MH type traverse
II. Stud profile
AQUAPANEL® Traverse: installation
AQUAPANEL® Traverse
Sanitary mounts
To ensure light console loads are borne securely, AQUAPANEL® Traverses
Standard sanitary mounts are used to bear greater loads. Various types
of mount are available for the various sanitary objects. Sanitary mounts
are secured using either side U-bracing profiles or are anchored directly
into the original flooring. Manufacturer guidelines should be followed
when assembling.
are attached between the C-wall profiles. The cross panels should be
secured twice on each side using crimping pliers. Alternatively, the cross
panels can be secured with self-tapping screws.
Doors are verified waterproof (test report BB 0215069, LGA Bavaria).
AQUAPANEL® Access Doors create a dust-proof and airtight closure
(classification according to DIN EN 1026 and DIN EN 12207; Class
4) and are smoke-proof according to DIN 18095.
Types
For single layer panelling, the following maximum loads apply:
M type: up to 0.7kN/m
MH type: up to 1.5kN/m
For single layer panelling with tiled AQUAPANEL® Cement Board
Indoor or double layer panelling, the following maximum loads apply:
M type and MH type: up to 1.5kN/m
AQUAPANEL® Access Doors are available in two different type:
AQUAPANEL® Access Door Splash Water Protection: This
universal splashproof type provides a dust-proof and airtight
closure, can be installed in wall and ceiling applications and is
also suitable for single and double layer panel structures as well
as for tiling and plastering. This type has a 4 mm coated edge
AQUAPANEL® Access Door Humid Rooms: This second type for
use in areas where splash-water resistant properties are not
required. It can be supplied with a coated edge to order which
allows the easy application of AQUAPANEL® Q4 Finish and is
suitable for use in walls and ceilings. Versions are available for
single and double layer walls
AQUAPANEL® Access Door Splash Water Protection
The size and position of the access door opening depends on the
substructure. The wall opening dimension depends on the size and
width of the frame of the AQUAPANEL® Access Door. The opening
must be 20 mm bigger than the frame of the AQUAPANEL® Access
Door Splash Water Protection.
AQUAPANEL® Access Door Humid Rooms
The size and position of the access door opening depends on the
substructure. The wall opening dimension depends on the size and
width of the frame of AQUAPANEL® Access Door. The opening must
be 12 mm bigger than the frame of the AQUAPANEL® Access Door
Humid Rooms.
Fix in place avoiding any distortion. Align the closing system towards
the ceiling. Screw the outer frame to the wall substructure and adjust
and secure the inside cover safety hinges. Then place the inner cover in
position, check that it functions properly, and finish the wall panelling.
Installation time
Approx. 30 – 45 minutes (depending on the size and accessibility of
the opening in the substructure)
Construction
AQUAPANEL® Traverse
Axis frame dimensions
600/625 mm
Height
approx. 290 mm
Thickness of metal
0 .75 mm with special anti-corrosion layer
M type
W ithout impregnated wood packing
MH type
With core-impregnated MDF filler,
approx. 18 mm thick
T he frame is made of anodised aluminium with an internal cover
which can be swung out and completely removed
Corrosion-resistant profiles and hinges for damp rooms
AQUAPANEL® Cement Board Indoor can be glued flush into
position (single and double layer type)
Splash-proof AQUAPANEL® Access Doors are fitted with a zero
maintenance seal
AQUAPANEL® Access Doors can be easily installed into partition and
installation walls with AQUAPANEL® Cement Board Indoor and are
available in different type.
AQUAPANEL® Traverse: arrangement and loading
40 _ 41
Tool recommendations
for building interior walls with Knauf Wetroom Solutions
Method of delivery
Panelling with AQUAPANEL® Cement Board Indoor
Panel thickness 12.5 mm
2 x 12.5 = 25 mm
Standard dimensions WxH*
200 x 200 mm (for humid areas)
300 x 300 mm
400 x 400 mm
500 x 500 mm
600 x 600 mm
AQUAPANEL® Access Door Splash Water Protection
Item code:
300 x 300 mm*: 140026
Schematic drawing: water spray protected access panel
Knife
Pendulum jigsaw
Use to cut insulation to
appropriate size
For sharp-edged cuts and to
make cut-outs for wiring and
pipes, use a pendulum jigsaw
fitted with a carbide or diamondtipped blade. The diameter of
the hole for a pipe should be
approximately 10 mm larger
than that of the pipe.
Scissors/shears
Screw gun
Use to cut metal profiles
To fasten the boards with screws
use a screw gun with depth
control. This ensures that all
screws are countersunk in the
same correct way.
Knife
Agitator
Use to cut cement boards and
Gypsum Boards: mark the
required size on the board with a
ruler and pencil. Score one side
with a knife, cutting through the
mesh or paper. Snap the board
along the score. Then cut the
mesh/paper on the opposing side.
Use to mix interior plasters,
skimcoats and exterior renders.
A tool with 600 rpm is
recommended.
Hand held circular saw
Knauf PFT G4/G5
For sharp-edged cuts, use a
hand-held circular saw with a dust
extractor fitted with a carbide or
diamond-tipped blade.
Use to mix interior plasters,
skimcoats and exterior renders.
Schematic drawing: wet room access panel
AQUAPANEL Access Door Humid Rooms
Item code:
300 x 300 mm*: 140027
* Other sizes on request.
®
Note: Both access door types are available in a range of sizes and are fitted with corrosion-resistant
profiles and hinges, multiple purpose for wall and ceiling. Doors come with AQUAPANEL® Maxi Screw
SB 39 and are available with key locking system on request.
Material Consumption (walls and ceilings)
Material requirement
AQUAPANEL® Cement Board Indoor
AQUAPANEL ® Maxi Screws (SN, SB)
AQUAPANEL ® Maxi Screws (SN, SB)
AQUAPANEL ® Maxi Screws (SN, SB)
AQUAPANEL ® Joint Adhesive (PU)
AQUAPANEL ® Board Primer
AQUAPANEL ® Joint Filler & Skim Coating – white
AQUAPANEL ® Reinforcing Mesh
AQUAPANEL ® Q4 Finish
GLASS FIBRE JOINT COVERING STRIP
Gypsum Board (single layer)
Drywall Screw
Uniflott
Trias
FUGENFÜller leicht
Readygips
Jointfiller Super
Multi-finish /Multi-finish M
Easyputz (1 mm grain size)
(0.5 mm grain size)
Joint Tape kURT
Tiefengrund
Spezialgrund
Putzgrund
Unit
m2
pieces
pieces
pieces
ml
g
kg; layer thickness 1 mm
m2
kg; layer thickness 1 mm
m
m2
pieces
kg
kg
kg
kg; joint filling, surface quality level Q2 (4AK boards)
kg; full surface scrape filling, surface quality level Q3 based on Q2
kg; full area skim coating e.g. surface quality level Q4
kg
kg; layer thickness 1 mm
g
g
m
ml
g
kg
Per m2
1
20, stud spacing 400 mm
25, stud spacing 300 mm
15, stud spacing 600/625 mm
50
40 -60
0.7 (3.5 dry layer thickness 5 mm)
1.1
1.7 (3.4 dry layer thickness 2 mm)
2.1
1
20
0.5
0.5
0.5
depends on joint ratio
0.7
1.5
0.6
1.0
950
500 – 650
2.1
70 – 100
100 – 200
0.25
42 _ 43
Tool recommendations
Reference of additional documentation
for building interior walls with Knauf Wetroom Solutions
Trowels
Use different kinds of trowels to
apply joint fillers, skim coats,
basecoat, renders etc
Information on interior systems with
Knauf Gypsum Board
W11 Knauf Metal Stud Partitions
Brandschutz mit Knauf
Knauf Wände – Schallschutz mit System – Anforderungen,
Empfehlungen, Berechnungsverfahren
Information on special interior Knauf panels
K716 Knauf Diamant
W15 Knauf Diamant
D179 Knauf Soundboard
K451 / K751 Fireboard
K717 Knauf Silentboard
K811 Knauf Vidiwall
W35 / W61 / W62 Massivbauplatte
Information on Knauf gypsum joint compounds
K432 Knauf Trennfix
K434 Knauf Dichtungsband
K442a Knauf Fugendeckstreifen Kurt
K451 Knauf Tiefengrund
K459 Knauf Spezialgrund
K462 Knauf Finish Pastös
K462 Knauf Fugenfüller Leicht
K463 Knauf Jointfiller Super
K464 Knauf Readygips
K467 Knauf Uniflott
Zeige mir deine Fugen und ich sag dir, wer du bist
Trockenausbau – einfach, schnell und sicher
Knauf Readygips – Hochwertige Oberflächen mit Spaßfaktor
Perfektion hat Hintergründe – Grundierungen von Knauf
Information on Knauf Insulation
Luftdichtheit schützt die Bausubstanz
Miscellaneous tools
Folding ruler
Pencil
Chalk line tool
Spirit level
44 _ 45
Notes
46 _ 47
All technical changes reserved. Only the current printed instructions are valid.
Our warranty is expressly limited to our products in flawless condition. The
constructional and structural properties and characteristic building physics of Knauf
systems can solely be ensured with the exclusive use of Knauf system components,
or other products expressly recommended by Knauf. All application quantities
and delivery amounts are based on empirical data that are not easily transferable
to other deviating areas. All rights reserved. All amendments, reprints and
photocopies, including those of excerpts, require the express permission of Knauf
USG Systems GmbH & Co. KG, Zur Helle 11, 58638 Iserlohn, Germany.
AQUAPANEL® is a registered trademark.
IDE A | DE SIGN | PL AN | RE ALISATION | COMPLE TION
© 2012 EN-03/12
Knauf Wetroom Solutions with AQUAPANEL® Technology Inside
is a technologically advanced building system. Because it’s a
system, it involves clear step-by-step process from design idea
to project completion. AQUAPANEL® cement board panels,
accessories and services work in unison – you can be certain
that your project will all come together as planned.
www.AQUAPANEL.com
Knauf USG Systems
GmbH & Co. KG
Zur Helle 11
58638 Iserlohn
Germany