XAP GWARE 116 Configuring microphone inputs for line-level devices Description Integrators often elect to provision unused microphone inputs for line-level devices. While this is normally not an issue, it can cause conflicts with Acoustic Echo Cancellation, microphone gating groups, and other speech-related features of the XAP product. To prevent any possible problems, follow the instructions below. To configure a mic input for use with line-level devices 1. Select the mic input and change the Coarse Gain to 0 dB. Turn the Phantom Power (P Pwr) off. 2. Click AEC to open the Acoustic Echo Canceller setup window. 3. Clear the Enable Acoustic Echo Canceller (AEC) check box. 4. Set the Non-linear Processing (NLP) to Off and then click Close to return to the Microphone Inputs window. 5. Click Gate to open the Gate window. 6. Turn off PA Adaptive Mode and Adaptive Ambient and then set the Activation to Manual – On. 7. In the Gating Group section, select None. Click Close. Gate settings for line-level input Mic input configured as a line-level input AEC settings for line-level input 02/25/03 ML Rev. 1.0 801-155-000-16 Rev. 1.0 ClearOne Technical Services Group 1825 Research Way, Salt Lake City, UT 84119 tel 1-800-283-5936 ~ 1-801-975-7200 Page 1 of 1