SUBSTATION INSTRUMENTATION CABLE Instrumentation Cable CONSTRUCTION AT A GLANCE Applications •Overall Jacket • Predominantly used in utility substations •H eat, Moisture and Sunlight Resistant Black Polyvinyl Chloride (PVC) CONDUCTOR TYPE 1 18 – 16 AWG Copper • Can be installed indoors or outdoors, direct burial, free air, raceways, encased in concrete, open trays, troughs, or continuous rigid cable support INSULATION TYPE 2 PVC/NYLON •Other Uses • Class 1 remote-control and signaling circuits JACKET TYPE 3 PVC • Class 1, Division 2 hazardous locations • Conductor operating temperatures are not to exceed 90°C wet or dry • Rated 600 Volts •Print • Pairs: Southwire X PR OAS XXAWG Shielded (UL) Type TC 600V THHN/ TFFN SUN RES DIR BURIAL RoHS (Month/Day/Year) Sequential footage marks • Triads: Southwire X TR OAS XXAWG Shielded (UL) type TC 600V THHN/TFFN SUN RES DIR BURIAL RoHS (Month/Day/Year) SequenSEQUENtial footage marks CONSTRUCTION DETAILS SPECIFICATIONS •Conductors Southwire’s Substation Instrumentation Cable meets or exceeds: • All Applicable ASTM Specifications • 18 or 16 AWG, 7 Strand, Annealed Bare Copper •Insulation • UL 83 • Tough, Heat and Moisture Resistant Polyvinyl Chloride (PVC) • UL1277 • UL1581 • UL 1685 • Color Code: (Pairs – Black, White, and Numbered) & (Triads – Black, White, Red, and Numbered) • Conductor Jacket: Clear Nylon (polyamide) •Assembly • Color-coded twisted pairs or triads; group of pairs or triads with numeric print identification on the groups • Overall aluminum polyester foil with 100% coverage, tinned drain wire • IEEE 1202 • ICEA T-30-520 • RoHS Compliant OPTIONS •Unshielded Pairs or Triads, with Overall Shield • XLP Insulated Conductors • Rip Cord 3 •Also Available in 300V Construction Upon Request 1 2 37 Section B Size Number of Triads inches Insulation Jacket Thickness Overall Jacket Thickness Nominal Core Diameter Nominal Overall Diameter mm inches mm inches mm inches mm inches mm Approximate Weight lbs/ kg/km 1000 ft 18 1 - 0.015 0.38 0.004 0.1 0.045 1.14 0.167 4.2 0.26 6.6 38 57 18 - 1 0.015 0.38 0.004 0.1 0.045 1.14 0.181 4.6 0.28 7.1 47 70 16 1 - 0.015 0.38 0.004 0.1 0.045 1.14 0.191 4.9 0.29 7.4 49 73 16 - 1 0.015 0.38 0.004 0.1 0.045 1.14 0.206 5.2 0.30 7.6 61 91 18 2 - 0.015 0.38 0.004 0.1 0.045 1.14 0.377 9.6 0.48 12.2 84 125 16 2 - 0.015 0.38 0.004 0.1 0.045 1.14 0.429 10.9 0.53 13.5 106 158 18 4 - 0.015 0.38 0.004 0.1 0.045 1.14 0.471 12.0 0.57 14.5 131 195 16 4 - 0.015 0.38 0.004 0.1 0.045 1.14 0.536 13.6 0.64 16.3 173 257 18 8 - 0.015 0.38 0.004 0.1 0.060 1.50 0.630 16.0 0.76 19.3 245 365 16 8 - 0.015 0.38 0.004 0.1 0.060 1.50 0.717 18.2 0.85 21.6 327 487 18 12 - 0.015 0.38 0.004 0.1 0.060 1.50 0.770 19.6 0.90 22.9 339 504 16 12 - 0.015 0.38 0.004 0.1 0.060 1.50 0.876 22.2 1.01 25.7 459 683 Dimensions and weights shown above are nominal and subject to industry tolerances. SUBSTATION INSTRUMENTATION CABLE AWG or Pairs kcmil Insulation Thickness Instrumentation Cable 38