Wall Window & Ceiling_14.qxd 16/11/2015 4:46 PM Page 23 SQ SERIES Wiring Diagram See pages N-6/7, diagrams DD 1, 2, 3, 9 A Weights See pages C-28/29 for details. ANCILLARY EQUIPMENT DESCRIPTION The SQ Series of square plate axial flow fans is a high quality, robust product with 9 sizes ranging from 315 to 1250mm diameter. They are suitable for a wide range of commercial and industrial applications. Typical Applications Capable of exhausting or supplying air in diverse environments ie. ambient air, hot air, as well as toxic, noxious, corrosive and explosive gases. See Special Note. Features Heavy duty, hot-dipped galvanised steel construction. Wide range of speeds and capacities available. Speed-controllable using variable speed drives. Conical inlet improves air flow and noise performance. Case available in other materials such as stainless steel. Can be supplied with special coatings. Tech-Lock® bushes are standard to facilitate the easy removal and fitting of impellers for cleaning and maintenance. Impeller blades are injection moulded GRP. Aluminium, nylon and anti-static blades are also available for explosion risk applications. For Smoke-Spill applications - The SQ Series has been tested to meet the air performance and high temperature test requirements of Standards AS/NZS1668.1:1998 and AS/NZS4429:1999. Can be mounted in any position. Extensive range of matching ancillary equipment available. Construction The square plate is of hot-dipped galvanised steel construction. Impellers are GRP. Aluminium, nylon and anti-static blades are also available. Motors Type - squirrel cage induction motor. Electricity Supply - 230V, single or 415V three-phase, 50Hz. Bearings - sealed for life, ball. Speed-controllable using variable speed drives. Maximum ambient when being speed-controlled is 40°C. Motors for a wide range of non-standard applications can be fitted. See pages O-3/4 for details of these motors. C..P - Circular silencers Ref. Section H-8/11 FG - Finger guards Ref. J-9 Variable speed drives Ref. Section M8/13 SPECIAL NOTE Quick selection envelope curves are shown on pages A-24/25. For more accurate selections refer to the Fans by Fantech Product Selections Program. Selection should be made using Type A installation (Free inlet, Free outlet). Refer to page C-2 for further information. SUGGESTED SPECIFICATION The square plate axial flow fans shall be of the SQ Series as designed and manufactured by Fantech Pty Ltd and be of the model numbers shown on the schedule/drawings. Square plates shall be of hot-dipped galvanised steel. Impellers shall be of GRP, nylon, aluminium or anti-static as required for the application. All performances shall be based upon tests to BS848:Part 1, 1980 or ISO5801: 1997 for air flow and BS848:Part 2, 1985 for noise. HOW TO ORDER - SQ SQ - square plate Air flow direction A B Fan diameter in cm Fan speed, no. of poles Hub diameter code A =150 D = 400 B = 250 F = 550 C = 350 G = 255 Aluminium blades, A GRP, P Nylon, N Anti-static blades E No. of blades Blade pitch angle, deg. Internal Thermal Protection Can be provided as an optional extra Testing Air flow testing to 1000mm dia - BS848:Part 1, 1980 1250mm dia - ISO5801:1997 Noise tests to BS848:Part 2, 1985 © FANTECH 2016 Scan the QR Code to view more information online. WALL, WINDOW & CEILING MOUNTED FANS A-23 Wall Window & Ceiling_14.qxd 16/11/2015 4:46 PM Page 24 SQ SERIES 2 Pole 48 rev/sec 1500 A 1000 77 80 pSF - Fan Static Pressure, Pa 600 76 73 400 80 69 70 200 m ste Sy nes Li 100 65 50 0.2 0.4 71 1.0 0.6 0562 0502 0402 65 0312 77 2.0 79 6.0 4.0 qV - Volume Flow, m /s 3 10.0 dB(A) @ 3m: Inlet Side = 4 Pole 24 rev/sec 1500 1000 89 600 em st s y S ne Li pSF - Fan Static Pressure, Pa 400 82 88 74 76 72 200 80 67 74 64 57 100 64 51 56 60 0634 0564 0504 50 40 74 70 69 1254 0804 0714 1004 0404 0314 20 0.2 0.4 66 56 53 1.0 0.6 69 2.0 71 76 76 6.0 4.0 91 80 10.0 20.0 qV - Volume Flow, m3/s 30.0 dB(A) @ 3m: Inlet Side = 6 Pole 16 rev/sec 600 80 pSF - Fan Static Pressure, Pa S Lin yste es m 400 200 79 73 62 100 70 69 70 61 58 60 43 47 42 0.4 0.6 63 54 1.0 61 2.0 qV - Volume Flow, m /s 3 A-24 1006 0406 0316 20 0.2 0506 1256 0806 0716 0636 0566 68 66 61 63 54 50 47 40 50.0 WALL, WINDOW & CEILING MOUNTED FANS 68 4.0 70 6.0 71 10.0 82 20.0 30.0 dB(A) @ 3m: Inlet Side = © FANTECH 2016 Wall Window & Ceiling_14.qxd 16/11/2015 4:46 PM Page 25 SQ SERIES 8 Pole 12 rev/sec 400 70 69 pSF - Fan Static Pressure, Pa 200 em st Sy ines L 64 1258 62 100 57 1008 64 0808 60 0718 56 57 55 59 0638 40 57 20 0.5 1.0 2.0 61 62 57 6.0 4.0 71 10.0 qV - Volume Flow, m /s 3 20.0 dB(A) @ 3m: Inlet Side = DIMENSIONS Model Number SQA/B.. Dimensions, mm A B CØ DØ EØ F1* 0312/4/6 430 380 315 382 9 420 0402/4/6 540 490 400 467 9 420 0502/4/6 655 615 500 587 11 460 0562/4/6 725 675 560 647 11 460 0634/6/8 805 750 630 717 11 460 0714/6/8 850 810 710 797 14 490 0804/6/8 970 910 800 887 14 490 1004/6/8 1170 1110 1000 1088 14 1254/6/8 1420 1360 1250 1338 14 4 x EØ Holes B A GB GA See Motor frame table Unit weights can be determined from pages C-28/29 * F1 is applicable to fans with motors up to D112M frame. See Motor frame table F2 for sizes D132S and above. CØ DØ Air flow Motor frame table Frame size D71 D80 D90S D90L D100L D112M D132S D132M D160M D160L D180M D180L F2† 345 385 425 425 480 480 560 560 695 695 730 730 Air flow Form B SQB.. Form A SQA.. GA** 369 435 464 489 567 610 643 683 753 798 819 859 GB** 409 475 504 529 607 650 683 723 793 838 859 899 F F † F2 is applicable to Ø310 to Ø800 fans with motors D132S frame and above and to all motor frame sizes for Ø1000 and Ø1200 fans. ** Dimensions GA & GB are approximate as they vary with the make of motor. © FANTECH 2016 WALL, WINDOW & CEILING MOUNTED FANS A-25 A