Luminite Genesis product range Wireless PIR detectors G1 Wireless PIR’s 30m x 20m G1 Wireless PIR’s 15m x 20m G1 Wireless PIR’s 40m x 4.5m G1 Wireless PIR’s 12m Horizontal curtain G1 Wireless PIR’s 12m Vertical curtain LGWP3020 LGWP1520 LGWP4004 LGWP12HC LGWP12VC G2 Wireless PIR’s G2 Wireless PIR’s LG2WP3020 LG2WP6004 30m x 20m 60m x 4m Wireless Accessories IP Masthead/Repeater Masthead/Repeater Masthead Relay Unit Relay Expansion Module Walk Test Instrument 16 way relay unit Relay module 16 way DM interface unit 16 way relay unit with end of line resistor Relay module with end of line resistor Optional antenna Transmitter module LGIP MT434 LGMT434 LGMRU4x4 LGREM4x4 LGWT434 LGRU16 LGRM8 LGDM16 LGRU16ELR 3 versions LGRM8ELR 3 versions AE434 LGTX434 Hard wired PIR detectors G1 Wired PIR’s 30m x 20m G1 Wired PIR 15m x 20m G1 Wired PIR 40m x 4.5m G1 Wired PIR 12m horizontal curtain G1 Wired PIR 12m vertical curtain LGHW3020 LGHW1520 LGHW4004 LGHW12HC LGHW12VC G2 Wired PIR’s G2 Wired PIR’s LG2HW3020 LG2HW6004 30m x 20m 60m x 4m Plug on wireless transmitter module Hard Wired PIR Detector Installation Handbook LG2TM434 Type: LG2 HW-3020 & HW-6004 2a BELLEVUE ROAD, FRIERN BARNET, LONDON, N11 3ER Tel: 0044 (0) 208 368 7887 Fax: 0044 (0) 208 368 3952 LUMINITE ELECTRONICS LTD, 2a BELLEVUE ROAD, FRIERN BARNET, LONDON, N11 3ER Tel: 0044 (0) 208 368 7887 Fax: 0044 (0) 208 368 3952 Web: www.luminite.co.uk email: sales@luminite.co.uk V2 Issue 2 PRE-INSTALLATION NOTES Detection Patterns. Unpacking. On receipt, inspect the package and contents for signs of damage. If damage has occurred, advise the carrier and/or suppliers immediately. Inspect the contents to confirm that all items are present and undamaged. If any items are missing or damaged, contact the supplier immediately. It is advisable that the original carton is retained as this forms the safest transport container in the event that a unit has to be returned for any reason. There are two mirror versions to choose from but the mirrors are not interchangeable. Servicing. This unit should not require general servicing. Any repair work should only be undertaken by qualified service personnel. Moisture. Do not expose the internal electronics of this unit to moisture i.e. take care during installation or when changing batteries not to allow rain or damp into the product. When the product is sealed it is water resistant to IP66. Take great care of the mirror surface. Do not scratch it or allow dust or dirt to settle on it. Model LGWP3020 Type 7 Box Contents. 1 x GENESIS hard wired G2 series PIR detector 1 x Rear tamper ring magnet 3 x no 8 wall plugs 3 x no 8 2” screws 1 x no 6 1/2” screw 1 x no 6 wall plug LG2HW-3020 & 6004 hard wired PIR Detector Specification. Mirror type Temp comp Power supply IP rating Enclosure Colour Temperature 30 metre x 20 metre or 60 metre x 4 metre. Detection / Anti Tamper / Anti Cloaking / Shock. Temperature sensor compensates for extreme conditions 12-24 volts AC or DC 66 High impact ABS with EPDM 1mm thick window Silver -10 +70c LG2 WP-3020 & WP-6004 Wireless PIR Detector Installation Handbook Page 2. Model LGWP6004 Type 6 Detection range will vary according to the air temperature and surrounding environment. For example: large areas of white concrete in very hot weather will reduce the sensitivity as will air temperatures of 37 degrees. If these situations occur and are present every day then it may be necessary to increase the sensitivity of the detector by following the instructions on page 11. 0 is the standard setting but can be increased in increments of +1 up to +5. LG2 HW-3020 & HW-6004 Hard Wired PIR Detector Installation Handbook Page 15. Testing & Commissioning. INDEX Adjust the mirror to the desired direction of detection . If you have an LG2TM434 test module, fit it now. Switch on the power and observe the momentary HI message on the display. Program the setting as required. Pages 10 & 11. If you are using the LGWT434 Walk Test Instrument, set ES to 0 It is recommended to set AND/OR to 1 and Pulse Count to at least 2. This will improve stability in environments where there is a lot of incidental movement from foliage and loose material. Fit the front cover to prevent air flow around the sensor during testing. DO NOT PUSH THE WHITE WINDOW. It is not necessary to secure the screw but be aware that the tamper will remain during testing until the screw is fitted. Using the LGWT434 Walk Test Instrument walk within the detection area, stopping and waiting for about five seconds each time detection occurs. The instrument will display D each time detection occurs. Lens type will display as Type 6 for the 6004 or Type 7 for the 3020. page Introduction. 4&5 Types of tamper. 5 Installation. 6 Mounting height and positioning. Minimising false alarms. 7 Wiring the detector. 8 Mirror adjustments. 9 Programming. 10 Mode options and Settings. 11, 12 & 13 Walk test transmitter 13 Testing and commissioning. 14 Detection patterns. 15 See the operating instructions for the walk tester for more information. Adjust the mirror as described on page 9 and re-test until optimum coverage is achieved. Once you are happy that the detector is operating to your requirements, remove the LG2TM434 module and screw the cover screw up from the bottom being careful not to cross thread it. It is good practice to switch the power off before removing the module but not essential. NB: Because the cover has a liquid tight gasket seal there will be an air pressure build up inside the product which will gradually normalise. The side effect of this will be to cause the sides around the gasket to lift slightly. Using the palms of your hands, gently push the sides in and towards the wall which will close up the gap. Be careful not to push the white window as damage will occur. LG2 HW-3020 & HW-6004 Hard Wired PIR Detector Installation Handbook Page 14. Copyright 2015 Luminite Electronics Ltd All rights reserved. Unauthorised duplication of this handbook by any means LG2 WP-3020 & WP-6004 Wireless PIR Detector Installation Handbook Page 3. Introduction The LG2HW3020 & LG2HW6004 hard wired Passive Infra Red Detectors (PIR) have been designed to meet the newest and most demanding requirements of the CCTV market. These new, stylish detectors are available in two different detection patterns and use superior Black Mirror Technology to provide excellent detection with minimal false alarms. The two ranges are: 30 metres out x 20 metres across or 60 metres out x 4 metres across. ENCLOSURE. LG2 detectors have a modern styling which disguises the product’s true function and helps them to blend in with modern architecturally designed buildings. The front window is made of pigmented HDPE which hides the mirror and the main body of the enclosure is ABS with a high quality paint finish. Both parts are UV stabilized and the weather proof rating is IP66. BLACK MIRROR TECHNOLOGY. These new PIR’s use mirror technology instead of Fresnel lenses. The large mirror provides significantly more optical gain which allows a thick EPDM front filtered window to be used without the need to increase sensitivity. White light from car headlights can cause false alarms, so it is important to filter out this interference. Most PIR detectors use pigmented windows or Fresnel lenses and sometimes an extra silicon filter to reduce white light, but this has the effect of also reducing the infrared energy and consequently detection range. The Black Mirror acts as a selective optical filter for body heat infrared with minimal loss while filtering out unwanted white light by as much as 14000 LUX. The combination of high optical gain and white light filtering means that the electronic sensitivity is much lower and therefore the risk of false alarms from electrical interference and component noise is greatly reduced. The other problem of running amplifiers at extremely high gain is that they reach saturation which obscures any signature that the micro controller would use to accurately determine the validity of a detection. The Luminite LG2 amplifier runs at a relatively low level and with the combination of the adaptive focal length optically sharp edges of each mirror segment together with the sophisticated detection algorithm has the result of accurate detection at various speeds and distances. LG2 HW-3020 & HW-6004 Hard Wired PIR Detector Installation Handbook Page 4. This module may also be left permanently fitted to enable wireless operation of a range of wireless receivers of both Genesis and Easyswitch types. The Easyswitch mode (option 1) changes the default Genesis transmission protocol to Easyswitch. Easyswitch is a range of wireless switching products and can be used to control lighting, sounders etc. There will soon be a new 16 way receiver (ESR16) which has relay alarm contacts and can be connected to other alarm equipment. For the latest updates and models see (Easyswitch products on our web site). Timer mode. This mode is for use with the Easyswitch option and tells the receiver how long to change the contact state for. It is adjustable from 0 to 127. These numbers do not translate to seconds and are different for each type of receiver. A conversion table is available on request. LG2TM module: It is good practice but not essential to turn off the power before fitting this module. Make sure that the module is orientated correctly and carefully plug it onto the pins on the right hand side of the top board. Now re apply the power and observe the HI on the display. By default this module will transmit Site code 32, Sub net 1 and Unit number 1. These settings cannot be changed. Use the Genesis LGWT434 walk test instrument to test the field of view. LG2TX M TRAN1 434 Plug LG2TM434 module onto these pins. LG2 HW-3020 & HW-6004 Hard Wired PIR Detector Installation Handbook Page 13. Sensitivity. The normal setting is 0. Low sensitivity is sometimes needed to reduce the detection distance. Higher sensitivity increases distance but also increases the risk of false activation from environmental conditions. AND / OR. The Genesis 2 PIR detector uses a Quad in line pyro sensor which acts like two separate sensors side by side. The AND / OR mode can select whether both sensors must detect movement together or whether only one or the other is required. AND gating is the best for filtering out nuisance alarms from loose materials, foliage and reflections. OR gating is more sensitive and may be selected when fast moving objects are to be detected. Power saving. Busy sites such as school playgrounds, car park entrances etc can cause an unnecessarily large number of alarm events during busy times. It is still possible to reduce them by invoking power saving mode. There are four types of power saving which may be selected to suit. 1. 2. 3. 4. An alarm can only be sent after 3 minutes of inactivity An alarm can only be sent after 10 minutes of inactivity An alarm can only be sent after 30 minutes of inactivity The same as 3 but with an accumulative timer which can extend the 30 minutes if the site remains very busy. In addition the sleep timer does not initiate after the first alarm but instead after a build up of activity. The next two options are for the LG2TM434 transmitter module. Easyswitch PIR mode. In the Genesis mode (option 0) this detector will behave like the Genesis 2 wireless version and can be used with the LGWT434 Walk Test Transmitter. After testing the transmitter can be removed and used to test other detectors. Alternatively leave the transmitter permanently fitted to facilitate both wireless and hard wired operation. LG2 HW-3020 & HW-6004 Hard Wired PIR Detector Installation Handbook Page 12. ADAPTIVE FOCAL LENGTH. The mirrors have adaptive focal length which regulates the image size for varying distances which helps regulate detection when the target is moving at faster or slower speeds regardless of distance from the detector. AND OR. The Quad in line pyro sensor splits each detection zone into two which are then labelled A and B. The G2 detector can be configured to go into alarm with either (A AND B) or (A OR B). AND detection is the best way to minimise false alarms as it filters out spurious movements from loose materials and foliage. SHOCK and CLOAK. The G2 PIR also contains a shock sensor to detect physical attack and IR transmission anti-masking. On the hard wired version, these alerts activate the anti masking relay but only momentarily. EXTERNAL POWER. The G2 detector is powered from an external supply (not supplied) which must be between 12-24 volts AC or DC and at least 200m/a. TYPES OF TAMPER: Front cover micro switch. Activated when the cover screw is removed. Rear tamper Hall effect and magnet. The magnet is fixed to the wall and when the product is removed the magnet is left behind. Shock sensor. Piezo sensor on mother board detects physical attack to the product. Anti masking. Active IR and LDR sense when the front window is obscured. These sensors always face the same direction as the mirror. LG2 HW-3020 & HW-6004 Hard Wired PIR Detector Installation Handbook Page 5. Installation: First, the front cover must be removed by unscrewing the bottom screw and lifting the cover just past the top of the gasket. Push the whole cover upwards so that it slides out off the retaining claws. (See diagram supplied in the carton). To fix the product to the wall and connect to the terminals, it is easier to remove the mirror assembly (recommended). Mirror removal procedure. Detach the mirror assembly by removing the white knurled nut and the R clip. 6 way plug Pull out the bottom spindle followed by the top threaded spindle. Unplug the 6 way Plug from the mother board and carefully place the assembly to one side ensuring that it does not Front cover claw sockets get wet or contaminated. The mirror must remain perfectly clean and scratch free. External power Knurled nut Screw hole & bung input Using the drill template provided, drill and plug the holes using the supplied wall plugs. Screw the rear tamper magnet in the centre using the No4 screw and yellow plug. Cable glands 6 way socket Place the product over the magnet so that it resides in the rear recess and then screw the product in place using the three No8 screws provided. Re-fit the black hole bungs provided to maintain the weather rating. Screw holes & bungs Front cover screw insert MODE OPTIONS: SETTINGS: IA It AL PL SE An PS ES tI 0 = (N/O) 1 = (N/C) 0 = (N/O) 1 = (N/C) 1 to 20 seconds 1 to 4 -5..0..+5 -5 Lowest, 0 Normal, +5 Highest 0 = OR 1 = AND 0-OFF, 1 to 4 ON (Four modes) 0 = Genesis 1 = Easyswitch 0...127 Idle alarm relay state Idle tamper relay state Activity length (contacts) Pulse counting Sensitivity AND/OR gating Power saving Easyswitch PIR mode Time adjust Idle alarm relay state. Changes alarm relay contacts from normally open (NO) to normally closed (N/C) Idle tamper relay state. Changes tamper relay contacts from normally open (NO) to normally closed (N/C) Activity length. Relay contact state change duration. 1 to 20 seconds. Default is 1 second Pulse counting. Counts the number of pulses caused when a person walks across the detector’s field of view. The greater the number, the more the person has to move to cause an alarm. Pulse count 1 is very sensitive while pulse count 4 is quite insensitive. Experiment with the setting to optimise the results so that persons are detected in good time but not so sensitive that the detector may be prone to false alarm from incidental movement from trees, shrubs, loose materials etc. 20mm Cable entry LG2 HW-3020 & HW-6004 Hard Wired PIR Detector Installation Handbook Page 6. LG2 HW-3020 & HW-6004 Hard Wired PIR Detector Installation Handbook Page 11. PROGRAMMING: The new version 2 model now has an LED display and push buttons to set the mode of operation. This makes changing settings much easier as the buttons and display are easily located on the top of the mirror. Button functions. SELECT M MEMORISE Mounting height and positioning: Mounting height TRAN1 M 2.5m To 4m UP DOWN Power On, When the power is turned on, the display shows Mounting height The correct height for the PIR is 2.5 metres above the ground, however it can be mounted up to 4 metres but the mirror must be angled down. See “mirror adjustments”. momentarily. How to set standard functions. Step 1. Enter the settings mode. Press M until the display shows IMPORTANT: Make sure that the rear tamper magnet has been fitted first using the template before fixing the product in place. Step 2. Scroll through the mode options with this button Minimising false alarms: Make sure that nothing can move or flutter in front of the detector and avoid facing reflective surfaces. The fixing of the detector must be solid and not sway. Avoid situations where the detector can overshoot the detection area. The Genesis 2 detector uses a patented Black Mirror which filters out unwanted sunlight however it is still good practice to consider the position carefully to minimise the possibility of reflections. EG: When the desired mode is reached, wait a moment and then the display will flash the setting. EG: = pulse count 1. To change a setting, select the mode and wait for the setting to flash. Scroll up or down to the desired number. Step 3. Press and hold the M button to store the new number. The display shows 6 way socket followed by Now let go of the button and the new setting is now stored. EXAMPLE: M M To change more than one setting at a time, follow steps 1 and 2 and after changing the setting press to select the next mode. Press the M button when all changes have been made. NB: The display will automatically turn off after 10 minutes if M is not pressed. 20mm Cable entry LG2 HW-3020 & HW-6004 Hard Wired PIR Detector Installation Handbook Page 10. LG2 HW-3020 & HW-6004 Hard Wired PIR Detector Installation Handbook Page 7. Wiring the detector: There are two IP66 rubber grommets at the rear of the detector which enable a 4-6mm diameter cable to be passed in and out of the product. There is also an alternative cable entrance at the bottom of the detector which is a knockout for a 20mm cable gland. Rear view showing the grommets and cable channel. Mirror adjustments: If the mirror assembly was removed, re-fit it now. Horizontal Left / Right adjustment is achieved by slackening the knurled white thumb screw and rotating the mirror assembly click by click in 10 degree steps to the required position. The degrees –90 0 +90 are shown in the picture. Fine adjustment from –5 to +5 degrees is achieved by rotating the Fine Adjust screw either clockwise or anti-clockwise. Top view Horizontal Coarse Adjust –90 +90 degrees Remove slide cover and knock out 20mm hole if using a cable gland. Power supply. This product has a special regulator which allows it to be powered from a variety of voltages ranging from 12 volts to 24 volts and they may be AC or DC. Once the power is connected the product will begin to operate. Allow two minutes for the circuit to settle before beginning walk testing. Alarm & Tamper. Both the alarm and tamper relays provide Volt Free contacts which can be configured to be N/O or N/C The contact duration is selectable from 1 to 10 seconds (see programming on page 10). Vertical Up / Down adjustment is achieved by adjusting the white plastic screw as shown. Horizontal Fine Adjust. ALARM TAMPER 12-24V AC or DC Vertical Adjust Mirror tilt. + 5 deg 0 deg -5 deg -10 deg -15 deg Walk Test Transmitter. A plug on test transmitter (LG2TM434) can be fitted to facilitate the test procedure. (See Testing and Commissioning on page 14). The transmitter can also be permanently fitted to provide a wireless link to Genesis or Easyswitch receivers. (See page 13) Aim the mirror in the direction you wish to protect and tighten the horizontal coarse adjust screw. It is not normally required that the mirror be tilted up or down and it should be left in the neutral 0 deg position. LG2 HW-3020 & HW-6004 Hard Wired PIR Detector Installation Handbook Page 8. LG2 HW-3020 & HW-6004 Hard Wired PIR Detector Installation Handbook Page 9.