JANUARY 28-31, 2013 SANTA CLARA CONVENTION CENTER Effects of Temperature and Relative Humidity in Transmission Systems Using Differential Signaling Authors • • • • • • • • • • Aldo Morales Email: awm2@psu.edu Sedig Agili Email: ssa10@psu.edu Mike Resso Email: mike_resso@agilent.com Jeff Clark Email: jmc5444@psu.edu Chris Kocuba Email: Chris.Kocuba@samtec.com Presentation Outline • • • • • • • Introduction Previous Research Experimental Set Up and Procedure Experimental Results Analysis Summary Acknowledgements References Introduction • In this paper, we explore the of humidity and temperature effects on PCB boards with differential signaling. • Of particular interest is S-parameters mode conversion due to the asymmetry induced by the moisture absorption in the differential lines. • Note hat asymmetry can also convert some of the differential signals into common signals. This asymmetry can also lead to signal skew that affects bandwidth, degrades rise time as well as increases electro-magnetic interference Previous Research • S21 measurements, microstrip using FR4 without solder mask • S21 measurements, microstrip using Rogers 4350 FR4 0.0300 inch thick microstrip line, dry and 7 days at 55 C 95% RH Rogers 4350 0.0300 inch thick microstrip line, dry and 7 days at 55 C 95% RH 0 0hr 24hrs -1 72hrs 120hrs 168hrs -2 0 0hr 24hrs 72hrs 120hrs 168hrs -2 -4 S21 (dB) -8 S 21 (dB) -6 -3 -4 -10 -5 -12 -6 -14 -16 0 5 10 15 Frequency (GHz) 20 25 -7 0 5 10 15 Frequency (GHz) 20 DesignCon 2010, “Evaluation of Relative Humidity and Temperature Effects on Scattering Parameters in Transmission Systems” 25 Previous Research • S21 magnitude measurements and curve fitting line. – S21 magnitude vs. time as 1GHz S21 magnitude vs. time as 20GHz DesignCon 2010 6 Previous Research •Soaked samples were exposed to 1 week of 30 ˚C and 60 % RH, S21 of GMS DesignCon 2012, “Temperature and Moisture Dependence of PCB and Package Traces and the Impact on Signal Performance,” Miller et. al. Previous Research DesignCon 2012, “Temperature and Moisture Dependence of PCB and Package Traces and the Impact on Signal Performance,” Miller et. al. Experimental Set Up and Procedures • Test devices: – Samtec golden standard – Milled – XAUI 9 Experimental Set Up • Temperature & humidity chamber – (-34)°C to 190°C – 10% to 98% RH • Performance Network Analyzer – Agilent E8364B (0 to 50 GHz) – SOLT calibration – Physical Layer Test System 10 Experimental Set Up • Temperature chamber for baking the DUTs • Mettler AE 100 lab scale – 100g capacity; – 0.0001g readability 11 Experimental Procedure Bake all DUTs at 80 oC for 4 days SOLT calibration S-parameter measurements of DUTs (dry state) SOLT Freq start: 50 MHz Freq end: 26 GHz IF bandwidth: 100 Hz 801 points Microstrip line test board Freq start: 50 MHz Freq end: 26 GHz IF bandwidth: 100 Hz 801 points 1 measurement each time Place DUTs in the environmental chamber kept at 55 oC and 95% RH S-parameters measurements of DUTs No Every 12 hours for 7 days complete? Yes Results analysis and S-parameter simulation 12 Experimental Results Analysis 13 Experimental Results Analysis 14 Experimental Results Analysis 15 Experimental Results Analysis 16 Experimental Results Analysis gldstd S12-parameters single ended gldstd S11-parameters single ended 0 0 0 Hrs 118 Hrs 7 days -5 0 Hrs 118 Hrs 7 days -10 -10 -20 -15 -30 S12 S11 -20 -25 -40 -30 -50 -35 -40 -60 -45 -50 -70 0 5 10 15 Frequency GHz 20 25 0 5 10 15 Frequency GHz 17 20 25 Experimental Results Analysis 18 Experimental Results Analysis 19 Experimental Results Analysis 20 Experimental Results Analysis XAUI far end crosstalk at 0 Hrs and 7 days XAUI near end crosstalk at 0 Hrs and 7 days 0 0 NEXT 0 Hrs NEXT 7 days -10 FEXT 0 Hrs FEXT 7 days -10 -20 -30 -30 -40 -40 dB dB -20 -50 -50 -60 -60 -70 -70 -80 -80 -90 0 1 2 3 Frequency GHz 4 5 6 -90 0 1 2 3 Frequency GHz 21 4 5 6 Conclusions and Future Work • Differential parameters, for all board analyzed, show consistent degradation in performance while mode conversion shows upswing in some regions of the boards’ range of operation • NEXT and FEXT are also affected in some regions of operation but the change seem to be less than mode conversion and in differential S-parameters • More research in how moisture absorption and temperature change the balance lines (for example layer placement) • Influence of the board weave. 22 References [1] Paul Hamilton, Gary Brist, Guy Barnes, Jr. & Jason Schrader, Humidity-dependent Loss in PCB Substrates in http://members.ipc.org/IPCLogin/IPCMembers/IPC/Route/0507/tech.pdf [2] J. Miller, Y. Li, K. Hinckley, G. Blando, B. Guenin, I. Novak, A. Dengi, A. Rebelo and S. McMorrow, “ Temperature and Moisture Dependence of PCB and Package Traces and the Impact on Signal Performance,” Proceedings of Designcon 12, Santa Clara, CA, 2012. [3] G. Sheets and J. D’Ambrosia “Evaluating Environmental Impact on Channel Performance,” CommDesign May 2004, http://www.commsdesign.com/design_corner/showArticle.jhtml?articleID=20300581. [4] S. Agili, A. Morales, J. Li and M. Resso, “Modeling Relative Humidity and Temperature Effects on Scattering Parameters in Transmission Lines, “ IEEE Transactions on Components, Packaging, and Manufacturing Technology, November-December 2012. [5] D.I. Amey, S.J. Horowitz, R.L. Keusseyan, “High Frequency Electrical Characterization of Electronic Packaging Materials: Environmental and Process Considerations,”. Proceedings of the 4th International Symposium Advanced Packaging Materials, 1998. [6] J-M Heinola, K-P. Lätti, P. Silventoinen, J-P. Ström, and M. Kettunen, “A Method to Evaluate Effects of Moisture Absorption on Dielectric Constant and Dissipation Factor of Printed Circuit Board Materials,” Proceedings of the 9th International Symposium on Advanced Packaging Materials: Processes, Properties and Interfaces, 2004. [7] H. Fremont, et al, “Measurements and FE-Simulations of Moisture Distribution in FR4-based Printed Circuit Boards”, 7th Int. Conf. On Thermal, Mechanical and Multiphysics Simulation and Experiments in Micro Electronics and Micro-Systems, EuroSimE 2006. 23 References [8] J. Li, M. Minns, A. Morales , S. Agili, M. Resso, “Evaluation of Relative Humidity and Temperature Effects on Scattering Parameters in Transmission Systems,” Proceedings of Desigcon10, February 2010, Santa Clara, CA. [9] E. Bogatin, Signal integrity Simplified, Prentice Hall, 2003. [10] J. Nadolny, S. Sercu, “Characterization And Impact Of Skew On Differential Connector Systems” Proceedings of 18th International Zurich Symposium on Electromagnetic Compatibility, Zurich, Switzerland, February 20-22, 2001. [11] J. Nadolny, J. Ferry, and C. Arroyo, “Mode Conversion and EMI Performance of Shielded Cable Assemblies for 10 Gbps Data Transmission,” Proceedings of Desigcon08, February 2008, Santa Clara, CA. [12] C. Di Minico and P. Kish, “Development of Equal Level Far-End Crosstalk (ELFEXT) and Return Loss Specifications for Gigabit Ethernet Operation On Category 5 Copper Cabling,” at www.ieee802.org/3/an/public/material/diminico_IWCS.PDF last accessed 12/01/2012. 24 Acknowledgements This research was possible thanks to the following Sponsors: 25 Thank you for your attention I welcome your questions.. QUESTIONS?