Compact Circuit Protector Compact, finger-safe fused disconnect offers superior protection Delivers up to 200kA SCCR in a compact, finger-safe design. Product description: Features and benefits: The revolutionary Bussmann Compact Circuit Protector (CCP) is designed as a fused branch circuit rated disconnect with a footprint 2/3 the space required by a traditional fusible switch. • Available Class CC fuse and CF CUBEFuse™ versions feature a high 200kA Short-Circuit Current Rating (SCCR) at 600V that can help increase assembly SCCR. These high ratings and compact design make the CCP ideal for industrial control panels, industrial machinery and HVAC applications. • • • • • With just 2/3 the space required by a traditional fusible switch, the CCP saves panel space. 200kA SCCR with Low-Peak™ CUBEFuse and Class CC fuses helps provide high assembly SCCR. UL 98 Listed, horsepower rated fused disconnect.* Built-in switch/fuse interlock prevents fuse removal while energized. Open fuse indication lights speed troubleshooting. No tools required for mounting onto DIN-Rail. * Class CC and CF versions with time-delay fuses. Bussmann is now a part of Eaton. Same great products plus even more. Learn more at www.eaton.com/cooper. Specifications for CC, Midget and 10x38 Versions Agency Information: Construction: RoHS Specifications for compliant, CCP CC, midget and 10x38 IP20 compliant with 10AWG or larger wire versions Wire Range: 18-6AWG single or dual rated, solid or stranded, Wire range: 18-6AWG singleCu oronly dual rated (same size wire), 4AWG single, 75ºC solid or stranded 4AWG single, 75ºC Cu only Torque Rating: 18-10AWG 20Lb-In Torque rating: 18-10AWG 8-4AWG20Lb-In 35Lb-In 8-4AWG 35Lb-In Poles: 1-, 2- and 3-pole: AC Version Poles: 1-, 1-pole: 2-, and 3-pole: AC version DC Version 1-pole: DC version Operating Temperature: -20ºC to 75ºC Operating temperature: -20ºC Flammability Rating: UL 94V0to 75ºC* Flammability rating: UL 94V0 Padlockable: YES Padlockable: Yes YES Local Indication: Mounting: DIN-Rail Local indication: Yes Mounting: DIN-Rail UL Class CC fuse version • UL 98information: Listed, File E302370, Guide WHTY Agency • cULus tofuse CSA Standard UL Class CC version 22.2 No. 4-04, File 302370, Guide WHTY7 • UL 98 Listed, File E302370, Guide WHTY • CE Compliant • cULus to CSA Standard 22.2 No. 4-04, File 302370, Guide WHTY7 UL Midget fuse version CE Compliant • UL 508 Listed RoHS Compliant • cULus Certified 22.2 No. 14-05 UL•midget fuse version CE Compliant • UL 508 Listed 10X38 IEC Class aM and gG/gL fuse version • cULus Certified 22.2 No. 14-05 • IEC 60947-3 AC23A • CE Compliant • IEC 60947-3 DC23A 10x38 IEC Class aM and gG/gl fuse version • CE Compliant • IEC 60947-3 AC23A • IEC 60947-3 DC23A • CE Compliant • • * For fuse performance under or above 25ºC, consult fuse performance charts in the Bussmann Selecting Protective Devices handbook (No. 3002). 1-pole Class 80Vdc CCP 1-, 2-, and 3-pole Class CC and Midget CCP Technical ratings Catalog number Amp Poles rating CCP-1-30CC Specifications CCP-2-30CC Amp rating Fuse class CCP-3-30CC Voltage rating 1 30 600Vac 2 30 600Vac No. of poles 3 Volts 200kA 0.5 200kA — 1 600Vac CC 2 600Vac 30 CC 3 600Vac 10x38 IEC 30 UL midget 32* 10x38 IEC CCP-2-30M 30 UL midget 32* 10x38 IEC 30 CC CCP-3-30M CC 30 32* 2 1 2 3 10x38 IEC 200kA 240Vac* 10kA† 400Vac† 400Vac* 120kA† 240Vac† † 400Vac 30 240Vac 400Vac† 30A 200kA Class CC 30A 200kA UL— IEC — 240 Vac 480 Vac 600 Vac — — — 2 — — 3 4 Midget 7.5 Class CC UL — 10x38 IEC — — — 240Vac* UL— UL Midget 120kA† 10kA † 400Vac* IEC — 10x38 — IEC — 120kA† 1 80Vdc 20kA† UL— UL Midget — — 240Vac* 1 80Vdc† 10kA IEC — 10x38 — IEC — 400Vac* 1 30 — 30 † 80Vdc* † SCCR May be lower, refer to installed fuse data sheets. Wire size/ (torque†††) 30A 30A Single/dual 8-6AWG sol/str 32A aM, 25A gG 10kA† † * 32A Class aM, 25A Class gG. CCP-1-DCC 30 † 240Vac † 3 120 Vac 600Vac CC 1 SCCR SCCR Class CC Max horsepower rating 30 30 32* Max. fuse ampacity 1-, 2-, and 3-pole Class CC and Midget CCP 30 30CCP-1-30M UL midget Fuse type — Single 30A 4AWG sol/str Spade 32A — aM, 25A gG terminal†† — 30A — aM, 25A gG 32A Class CC 30A (DC rated) Wire type 200kA 30 - 8-4AWG; 35 Lb-In 80Vdc* UL Midget 30A 10x38 IEC 32A aM, 25A gG UL 9880Vdc ListedCCP 1-pole Class cULus 22.2 No. 4-04 UL 98 Listed cULus 22.2 No. 4-04 Hp ratings 0.5Hp@120V 2.0Hp@240V Part number UL 3Hp@240V Agency information 98 Listed 5Hp@480V CCP-1-30CC UL 98 Listed, cULus 22.2 No. 4-04cULus 22.2, No. 4-04 7.5Hp@600V CCP-2-30CC UL 98 Listed, cULus 22.2, No. 4-04 UL 508 Listed 10kA* CCP-3-30CC UL 98 Listed, cULus 22.2, No. 4-04 cULus 22.2 14-05cULus 22.2, —No. 14-05 UL No. 508 Listed, 120kA* CCP-1-30M IEC 60947-3, IEC 60947-3 AC23AAC23A UL Listed 508 Listed, cULus 22.2, No. 14-05 75°C Cu UL 508 CCP-2-30M or10kA* higher IEC 60947-3, AC23A cULus 22.2 No. 14-05 — UL 508 Listed, cULus 22.2, No. 14-05 120kA* CCP-3-30M IEC 60947-3 AC23A IEC 60947-3, AC23A UL 508 Listed 10kA* CCP-1-DCC UL 98 Listed, CSA 22.2, No. 4-04 cULus 22.2 No. 14-05 — UL 508 Listed, cULus 22.2, No. 14-05 120kA* CCP-1-DCM IEC 60947-3 AC23ADC23A IEC 60947-3, 20kA* UL 98 Listed CSA 22.2 No. 4-04 — UL 508 Listed †† Spade terminal with a 4.3mm gap for a #8-32 stud, 30A max, insulated flange, wire size 12-10AWG. CCP-1-DCM 1 ††† - 18-10AWG; 20 Lb-In Agency approvals 10kA* cULus 22.2 No. 14-05 — IEC 60947-3 DC23A *Rating may be lower depending on installed fuse. Refer to fuse data sheet. Recommended IEC fuse types Recommended fuse types Class CC LP-CC KTK-R FNQ-R AC voltage Midget KTK FNM FNQ BAF Class CC LP-CC DC voltage Midget KLM 10x38 IEC Part number IEC family Class C10G gG/gL C10M aM Specifications for CCP_CF CUBEFuse version Construction: IP20 compliant with 10AWG or larger wire. Operating temperature: -20ºC to 75ºC* Amp ratings: 30, 60, 100A Padlockable: Yes Wire range (75°C Cu or higher): 30-60A 18-6AWG, single/dual, solid/stranded 4AWG, single, solid/stranded 100A 8-10AWG, single, solid/stranded 8-1AWG, single, stranded 6AWG, dual, stranded Torque: 30-60A 18-10AWG, 20 lb-in 8-6AWG, 35 lb-in 4AWG, 35 lb-in 100A 8-10AWG, 25 lb-in 8-1AWG, 35 lb-in 6AWG, 45 lb-in Local indication: Yes Poles: Flammability rating: UL 94V0 Mounting: DIN-Rail Agency information: UL Class CF fuse version • UL 98 Listed, File E302370, Guide WHTY • cULus to CSA Standard 22.2 No. 4-04, File 302370, Guide WHTY7 • RoHS Compliant Ampacity rejection: CCP_CF disconnects will not accept CUBEFuse amp ratings greater than the switch rating. * For fuse performance under or above 25ºC, consult fuse performance charts in the Bussmann Selecting Protective Devices handbook (No. 3002). 1-, 2-, and 3-pole 1- and 2-pole 30A 3-pole 60A Specifications Amp rating UL fuse class No. of poles 30 CF 1 30 CF 2 30 CF 3 60 CF 1 60 CF 2 60 CF 3 Max horsepower rating* Volts SCCR 600Vac 200kA 125Vdc 100kA 600Vac 200kA 125Vdc 100kA 600Vac 200kA 125Vdc 100kA 600Vac 200kA 125Vdc 100kA 600Vac 200kA 125Vdc 100kA 600Vac 125Vdc 200kA 100kA 120 Vac 240 Vac 480 Vac 600 Vac 1.5 — — — — 3 — — — 5 15 10 Wire size (See note for torque†) Part number Agency information CCP-1-30CF UL 98 Listed, cULus 22.2, No. 4-04 CCP-2-30CF UL 98 Listed, cULus 22.2, No. 4-04 CCP-3-30CF UL 98 Listed, cULus 22.2, No. 4-04 CCP-1-60CF UL 98 Listed, cULus 22.2, No. 4-04 CCP-2-60CF UL 98 Listed, cULus 22.2, No. 4-04 CCP-3-60CF UL 98 Listed, cULus 22.2, No. 4-04 Single 8-10AWG sol/str 8-1AWG str CCP-1-100CF UL 98 Listed, cULus 22.2, No. 4-04 CCP-2-100CF UL 98 Listed, cULus 22.2, No. 4-04 Dual 6AWG str CCP-3-100CF UL 98 Listed, cULus 22.2, No. 4-04 Single/dual 18-6AWG sol/str 3 — — — Single 4AWG sol/str — 7.5 — — Spade terminal** — 7.5 20 10 100 CF 1 600Vac 200kA 5 — — — 100 CF 2 600Vac 200kA — 10 — — 100 CF 3 600Vac 200kA — 20 50 50 Wire type 75°C Cu or higher Spade terminal** * With time-delay Low-Peak CUBEFuse. **Spade terminal with a 4.3mm gap for a #8-32 stud, 30A max, insulated flange, wire size 12-10AWG. † 30-60A: - 18-10AWG 20 Lb-In - 8-6AWG 35 Lb-In - 4AWG 35 Lb-In 70-100A:- 8-10AWG single 25 Lb-In - 8-1AWG single 35 Lb-In - 6AWG dual 45 Lb-In Specifications for accessories Auxiliary contact Remote fuse monitoring NO+NC contact output to indicate the status of the switching mechanism on the CCP. A resetable three-phase fuse monitor that integrates with the I/O card in a Programmable Logic Controller (PLC). Specifications: • Rated ampacity: 5A • Rated voltage: 240Vac • NC/NO contacts are closed/open when the CCP switch is in the “ON” position (closed) • Flammability rating: UL 94V0 Specifications: • Power input: 24Vdc / 10mA max • Output signals: Digital 0Vdc (low), 24Vdc (high) - 0Vdc low - fuse is good - 24Vdc high - fuse has opened When the fuse opens, the output signal is sent high and will remain high until the unit is reset. Agency information: • UL 98 File E155130, Guide WHTY2 • cULus to CSA Standard 22.2 No. 4-04 • IEC 60947-5-1 • Rated impulse voltage: 8kA • Local indication: Two distinct LEDs indicate unit power (green) and open fuse (red). Upon the replacement of the fuse, the actuation of the reset switch will reset the open fuse LED. • Flammability rating: UL 94V0 Agency information: • UL 98 File E155130, Guide WHTY2 • cULus to CSA Standard 22.2 No. 4-04 CCP-PLC-IND (includes spade terminals CCP-AUX CCP-AUX accessories Description Auxiliary contacts NO+NC for switch status up to 60A Auxiliary contacts NO+NC for switch status 70 to 100A Max per CCP PLC fuse monitor Signal output 1 per CCP 5A/240Vac (1-, 2- or 3-pole) 1 per CCP 5A/240Vac (1-, 2- or 3-pole) Agency information UL 98 Recognized, cURus 22.2 No. 4-04, IEC 60947-51 AC15 UL 98 Recognized, CSA C22.2 No. 4 Catalog number Description CCP-AUX CCP-AUX-100 De-energize all circuits before installing or removing any CCP-AUX devices and follow all prescribed safety procedures. Eaton’s Bussmann Business 114 Old State Road Ellisville, MO 63021 United States www.bussmann.com www.cooperbussmann.com/ccp © 2014 Eaton All Rights Reserved Printed in USA Publication No. 3139 BU-SB14604 August 2014 Wired remote fuse indication for PLC applications up to 60A Wired remote fuse indication for PLC applications 70 to 100A Max per CCP Signal output to PLC Min. circuit volts Agency information UL 98 Recognized, 1 per CCP (1, 2- or 3-Pole) 24Vdc/ 10mA cURus 22.2 No. 4-04 Eaton is a registered trademark. All other trademarks are property of their respective owners. CCP-PLC-IND 100Vac UL 98 Recognized, CSA C22.2 No. 4 De-energize all circuits before installing or removing any CCP-PLC-IND devices and follow all prescribed safety procedures. For more information, see data sheet Nos. 1157 (CCP) and 1161 (CCPB), and application note No. 7038. Cat. no. CCP-PLC-100