Bussmann Compact Circuit Protector Product Profile # 3139

Compact Circuit Protector
Compact, finger-safe fused disconnect
offers superior protection
Delivers up to
200kA SCCR in a
compact, finger-safe
design.
Product description:
Features and benefits:
The revolutionary Bussmann
Compact Circuit Protector
(CCP) is designed as a
fused branch circuit rated
disconnect with a footprint
2/3 the space required by a
traditional fusible switch.
•
Available Class CC fuse and
CF CUBEFuse™ versions
feature a high 200kA
Short-Circuit Current Rating
(SCCR) at 600V that can
help increase assembly
SCCR. These high ratings
and compact design make
the CCP ideal for industrial
control panels, industrial
machinery and HVAC
applications.
•
•
•
•
•
With just 2/3 the space
required by a traditional
fusible switch, the CCP
saves panel space.
200kA SCCR with
Low-Peak™ CUBEFuse
and Class CC fuses helps
provide high assembly
SCCR.
UL 98 Listed,
horsepower rated fused
disconnect.*
Built-in switch/fuse
interlock prevents fuse
removal while energized.
Open fuse indication
lights speed
troubleshooting.
No tools required for
mounting onto DIN-Rail.
* Class CC and CF versions with time-delay fuses.
Bussmann is now a part of
Eaton. Same great products plus
even more. Learn more at
www.eaton.com/cooper.
Specifications for CC, Midget and 10x38 Versions
Agency Information:
Construction: RoHS
Specifications
for compliant,
CCP CC, midget and 10x38
IP20
compliant
with
10AWG or larger wire
versions
Wire Range: 18-6AWG single or dual rated, solid or
stranded,
Wire range:
18-6AWG
singleCu
oronly
dual rated (same size wire),
4AWG
single, 75ºC
solid or stranded 4AWG single, 75ºC Cu only
Torque Rating: 18-10AWG 20Lb-In
Torque rating: 18-10AWG
8-4AWG20Lb-In
35Lb-In
8-4AWG 35Lb-In
Poles: 1-, 2- and 3-pole: AC Version
Poles: 1-, 1-pole:
2-, and 3-pole:
AC version
DC Version
1-pole: DC version
Operating Temperature: -20ºC to 75ºC
Operating
temperature:
-20ºC
Flammability
Rating: UL
94V0to 75ºC*
Flammability
rating:
UL
94V0
Padlockable: YES
Padlockable:
Yes YES
Local Indication:
Mounting:
DIN-Rail
Local
indication:
Yes
Mounting: DIN-Rail
UL Class CC fuse version
• UL 98information:
Listed, File E302370, Guide WHTY
Agency
•
cULus
tofuse
CSA Standard
UL Class CC
version 22.2 No. 4-04, File 302370,
Guide
WHTY7
• UL 98 Listed, File E302370, Guide WHTY
• CE Compliant
• cULus
to CSA Standard 22.2 No. 4-04, File 302370,
Guide
WHTY7
UL Midget
fuse version
CE
Compliant
• UL
508 Listed
RoHS
Compliant
• cULus
Certified 22.2 No. 14-05
UL•midget
fuse version
CE Compliant
• UL 508 Listed
10X38 IEC Class aM and gG/gL fuse version
• cULus Certified 22.2 No. 14-05
• IEC 60947-3 AC23A
• CE Compliant
• IEC 60947-3 DC23A
10x38 IEC Class aM and gG/gl fuse version
• CE Compliant
• IEC 60947-3 AC23A
• IEC 60947-3 DC23A
• CE Compliant
•
•
* For fuse performance under or above 25ºC, consult fuse performance charts
in the Bussmann Selecting Protective Devices handbook (No. 3002).
1-pole Class 80Vdc CCP
1-, 2-, and 3-pole Class CC and Midget CCP
Technical ratings
Catalog
number
Amp
Poles rating
CCP-1-30CC
Specifications
CCP-2-30CC
Amp
rating
Fuse
class
CCP-3-30CC
Voltage
rating
1
30
600Vac
2
30
600Vac
No.
of
poles
3
Volts
200kA
0.5
200kA
—
1
600Vac
CC
2
600Vac
30
CC
3
600Vac
10x38 IEC
30
UL midget
32*
10x38 IEC
CCP-2-30M
30
UL midget
32*
10x38 IEC
30
CC
CCP-3-30M
CC
30
32*
2
1
2
3
10x38 IEC
200kA
240Vac*
10kA†
400Vac† 400Vac*
120kA†
240Vac†
†
400Vac
30
240Vac
400Vac†
30A
200kA
Class CC
30A
200kA
UL—
IEC
—
240
Vac
480
Vac
600
Vac
—
—
—
2
—
—
3
4
Midget
7.5
Class CC
UL
—
10x38 IEC
—
—
—
240Vac*
UL— UL Midget
120kA†
10kA
†
400Vac* IEC — 10x38
— IEC —
120kA†
1
80Vdc
20kA† UL— UL Midget
—
—
240Vac*
1
80Vdc†
10kA IEC — 10x38
— IEC —
400Vac*
1
30
—
30
†
80Vdc*
† SCCR May be lower, refer to installed fuse data sheets.
Wire size/
(torque†††)
30A
30A
Single/dual
8-6AWG
sol/str
32A aM,
25A gG
10kA†
†
* 32A Class aM, 25A Class gG.
CCP-1-DCC
30 †
240Vac
†
3
120
Vac
600Vac
CC
1
SCCR
SCCR
Class CC
Max horsepower rating
30
30
32*
Max. fuse ampacity
1-, 2-, and 3-pole Class CC and Midget CCP
30
30CCP-1-30M
UL midget
Fuse
type
—
Single
30A
4AWG sol/str
Spade
32A
— aM, 25A gG
terminal††
—
30A
— aM, 25A gG
32A
Class CC
30A
(DC rated)
Wire
type
200kA
30
- 8-4AWG; 35 Lb-In
80Vdc*
UL Midget
30A
10x38 IEC
32A aM, 25A gG
UL 9880Vdc
ListedCCP
1-pole Class
cULus 22.2 No. 4-04
UL 98 Listed
cULus 22.2 No. 4-04
Hp ratings
0.5Hp@120V
2.0Hp@240V
Part
number
UL
3Hp@240V
Agency information
98 Listed
5Hp@480V
CCP-1-30CC
UL 98
Listed,
cULus 22.2
No.
4-04cULus 22.2, No. 4-04
7.5Hp@600V
CCP-2-30CC UL 98 Listed, cULus 22.2, No. 4-04
UL 508 Listed
10kA* CCP-3-30CC UL 98 Listed, cULus 22.2, No. 4-04
cULus 22.2
14-05cULus 22.2,
—No. 14-05
UL No.
508 Listed,
120kA*
CCP-1-30M
IEC 60947-3,
IEC 60947-3
AC23AAC23A
UL Listed
508 Listed, cULus 22.2, No. 14-05
75°C Cu
UL 508
CCP-2-30M
or10kA*
higher
IEC 60947-3, AC23A
cULus 22.2 No. 14-05
—
UL 508 Listed, cULus 22.2, No. 14-05
120kA* CCP-3-30M
IEC 60947-3 AC23A
IEC 60947-3, AC23A
UL 508 Listed
10kA* CCP-1-DCC UL 98 Listed, CSA 22.2, No. 4-04
cULus 22.2
No. 14-05
—
UL 508 Listed, cULus 22.2, No. 14-05
120kA* CCP-1-DCM
IEC 60947-3
AC23ADC23A
IEC 60947-3,
20kA*
UL 98 Listed
CSA 22.2 No. 4-04
—
UL 508 Listed
†† Spade terminal with a 4.3mm gap for a #8-32 stud, 30A max, insulated flange, wire size 12-10AWG.
CCP-1-DCM
1
†††
- 18-10AWG; 20 Lb-In
Agency
approvals
10kA*
cULus 22.2 No. 14-05
—
IEC 60947-3 DC23A
*Rating may be lower depending on installed fuse. Refer to fuse data sheet.
Recommended IEC fuse types
Recommended fuse types
Class CC
LP-CC
KTK-R
FNQ-R
AC voltage
Midget
KTK
FNM
FNQ
BAF
Class CC
LP-CC
DC voltage
Midget
KLM
10x38 IEC
Part number
IEC
family
Class
C10G
gG/gL
C10M
aM
Specifications for CCP_CF CUBEFuse version
Construction:
IP20 compliant with 10AWG or larger wire.
Operating temperature: -20ºC to 75ºC*
Amp ratings: 30, 60, 100A
Padlockable: Yes
Wire range (75°C Cu or higher):
30-60A 18-6AWG, single/dual, solid/stranded
4AWG, single, solid/stranded
100A 8-10AWG, single, solid/stranded
8-1AWG, single, stranded
6AWG, dual, stranded
Torque:
30-60A 18-10AWG, 20 lb-in
8-6AWG, 35 lb-in
4AWG, 35 lb-in
100A 8-10AWG, 25 lb-in
8-1AWG, 35 lb-in
6AWG, 45 lb-in
Local indication: Yes
Poles:
Flammability rating: UL 94V0
Mounting: DIN-Rail
Agency information:
UL Class CF fuse version
• UL 98 Listed, File E302370, Guide WHTY
• cULus to CSA Standard 22.2 No. 4-04, File 302370,
Guide WHTY7
• RoHS Compliant
Ampacity rejection: CCP_CF disconnects will not accept
CUBEFuse amp ratings greater than the switch rating.
* For fuse performance under or above 25ºC, consult fuse performance charts
in the Bussmann Selecting Protective Devices handbook (No. 3002).
1-, 2-, and 3-pole
1- and 2-pole 30A
3-pole 60A
Specifications
Amp
rating
UL
fuse
class
No.
of
poles
30
CF
1
30
CF
2
30
CF
3
60
CF
1
60
CF
2
60
CF
3
Max horsepower rating*
Volts
SCCR
600Vac
200kA
125Vdc
100kA
600Vac
200kA
125Vdc
100kA
600Vac
200kA
125Vdc
100kA
600Vac
200kA
125Vdc
100kA
600Vac
200kA
125Vdc
100kA
600Vac
125Vdc
200kA
100kA
120
Vac
240
Vac
480
Vac
600
Vac
1.5
—
—
—
—
3
—
—
—
5
15
10
Wire size
(See note
for torque†)
Part
number
Agency information
CCP-1-30CF
UL 98 Listed, cULus 22.2, No. 4-04
CCP-2-30CF
UL 98 Listed, cULus 22.2, No. 4-04
CCP-3-30CF
UL 98 Listed, cULus 22.2, No. 4-04
CCP-1-60CF
UL 98 Listed, cULus 22.2, No. 4-04
CCP-2-60CF
UL 98 Listed, cULus 22.2, No. 4-04
CCP-3-60CF
UL 98 Listed, cULus 22.2, No. 4-04
Single
8-10AWG sol/str
8-1AWG str
CCP-1-100CF
UL 98 Listed, cULus 22.2, No. 4-04
CCP-2-100CF
UL 98 Listed, cULus 22.2, No. 4-04
Dual 6AWG str
CCP-3-100CF
UL 98 Listed, cULus 22.2, No. 4-04
Single/dual
18-6AWG sol/str
3
—
—
—
Single
4AWG sol/str
—
7.5
—
—
Spade terminal**
—
7.5
20
10
100
CF
1
600Vac
200kA
5
—
—
—
100
CF
2
600Vac
200kA
—
10
—
—
100
CF
3
600Vac
200kA
—
20
50
50
Wire
type
75°C Cu
or higher
Spade terminal**
* With time-delay Low-Peak CUBEFuse.
**Spade terminal with a 4.3mm gap for a #8-32 stud, 30A max, insulated flange,
wire size 12-10AWG.
† 30-60A: - 18-10AWG 20 Lb-In
- 8-6AWG 35 Lb-In
- 4AWG 35 Lb-In
70-100A:- 8-10AWG single 25 Lb-In
- 8-1AWG single 35 Lb-In
- 6AWG dual 45 Lb-In
Specifications for accessories
Auxiliary contact
Remote fuse monitoring
NO+NC contact output to indicate the status of the
switching mechanism on the CCP.
A resetable three-phase fuse monitor that integrates with
the I/O card in a Programmable Logic Controller (PLC).
Specifications:
• Rated ampacity: 5A
• Rated voltage: 240Vac
• NC/NO contacts are closed/open when the CCP switch
is in the “ON” position (closed)
• Flammability rating: UL 94V0
Specifications:
• Power input: 24Vdc / 10mA max
• Output signals: Digital 0Vdc (low), 24Vdc (high)
- 0Vdc low - fuse is good
- 24Vdc high - fuse has opened
When the fuse opens, the output signal is sent high and
will remain high until the unit is reset.
Agency information:
• UL 98 File E155130, Guide WHTY2
• cULus to CSA Standard 22.2 No. 4-04
• IEC 60947-5-1
• Rated impulse voltage: 8kA
• Local indication: Two distinct LEDs indicate unit power
(green) and open fuse (red). Upon the replacement of the
fuse, the actuation of the reset switch will reset the open
fuse LED.
• Flammability rating: UL 94V0
Agency information:
• UL 98 File E155130, Guide WHTY2
• cULus to CSA Standard 22.2 No. 4-04
CCP-PLC-IND
(includes spade terminals
CCP-AUX
CCP-AUX accessories
Description
Auxiliary contacts
NO+NC for switch
status up to 60A
Auxiliary contacts
NO+NC for switch
status 70 to 100A
Max per
CCP
PLC fuse monitor
Signal
output
1 per CCP
5A/240Vac
(1-, 2- or 3-pole)
1 per CCP
5A/240Vac
(1-, 2- or 3-pole)
Agency
information
UL 98
Recognized,
cURus 22.2
No. 4-04,
IEC 60947-51 AC15
UL 98
Recognized,
CSA C22.2
No. 4
Catalog
number
Description
CCP-AUX
CCP-AUX-100
De-energize all circuits before installing or removing any CCP-AUX devices and
follow all prescribed safety procedures.
Eaton’s Bussmann Business
114 Old State Road
Ellisville, MO 63021
United States
www.bussmann.com
www.cooperbussmann.com/ccp
© 2014 Eaton
All Rights Reserved
Printed in USA
Publication No. 3139 BU-SB14604
August 2014
Wired remote
fuse indication
for PLC
applications up
to 60A
Wired remote
fuse indication
for PLC
applications 70
to 100A
Max
per
CCP
Signal
output
to PLC
Min.
circuit
volts
Agency
information
UL 98
Recognized,
1 per
CCP
(1, 2- or
3-Pole)
24Vdc/
10mA
cURus 22.2
No. 4-04
Eaton is a registered trademark.
All other trademarks are property
of their respective owners.
CCP-PLC-IND
100Vac
UL 98
Recognized,
CSA C22.2 No. 4
De-energize all circuits before installing or removing any
CCP-PLC-IND devices and follow all prescribed safety procedures.
For more information, see data sheet
Nos. 1157 (CCP) and 1161 (CCPB), and
application note No. 7038.
Cat.
no.
CCP-PLC-100