Helical Fittings - Fulton Industries Australia

advertisement
Helical Fittings
EXCLUSIVE AUSTRALIAN DISTRIBUTORS
ONLINE-CATALOGUE
B4/1 Introduction in helical fittings
Helical fittings are composed of single helical rods which -according to the respective application - are separate or preassembled, straight or looped on delivery.
Helical fittings involve such a variety of applications that still nowadays, it cannot be forseen for which applications of everyday life they can be used too.
This catalogue volume B4 in respect of the application of helical fittings mainly refers to electrical engineering and especially to the use on overhead lines and distribution
systems. Preformed accessories can be used to tension, to suspend and to connect conductors, cables, glass fiber rods and also solid rods as for instance guys.
In addition preformed accessories are employed to protect or to repair conductors, for attachment to post insulators, as spacers on bundled conductors and for tensioning
the suspension of street lighting.
They are also successfully used to mark conductors against collision of birds with them (bird flight diverters).
Preformed accessories have very successfully been used since 1950. The employment of helical fittings is not at all limited to overhead lines only. Preformed accessories
in a large measure are also used for the construction of antennas, radar stations etc.
The helical fittings included in this catalogue volume have introduced a new design in Germany which distinguishes by its simplicity and reliability.
The Richard Bergner Company has started the production of helical fittings in 1959 and in the meantime, the helically fittings designs have been adapted to the specific
requirements in Germany and Europe.
The effect of helical fittings is mostly based on the principle of development of a low unit pressure over a large area:
The inside diameter of the unloaded helical rods is slightly smaller than the outside diameter of conductor, cable or solid rod. By wrapping the helical rods on a conductor, a
spring tension is created producing the necessary frictional contact. This spring tension is of elastic nature and ensures a constant gripping.
If conductor, cable or solid rod are subject to tension load, the gripping force increases as the tension load increases. The inside of helical rods may be sanded or the
conductor surface be covered with a friction bond to improve the contact. The gripping force in any case is so high that under tension load - correct dimensioning provided
rather the conductor fails than the fitting.
To ensure the full performance, the helical fitting must exactly be adapted to the outside diameter of conductor, cable or solid rod. In addition, helical fitting and outer strand
of conductor must be of same lay direction. Unless specified otherwise, helical fittings are of right-hand lay on delivery. Hence, it is necessary to specify on order if helical
fittings for left-hand lay conductors are required.
In general, helical fittings are made from a material similar to that of conductor or solid rod providing thus a corrosion resistance of fitting equal to that of conductor or rod.
The helical rods can be installed without use of any tool. Incorrect assembly is almost impossible. It can be detected by eyesight whether accessory was correctly installed.
Hence, helical fittings can be installed by unskilled workers. Mounting instructions are available on demand (see also catalogue).
Helical fittings are provided with a label stating for which funtion and for what conductors, cables or solid rods the respective accessory is designed for. In addition you find
data of production on it securing actions according to DIN EN ISO 9001.
It is recommended to remove this label only immediately before assembly or better - if possible - don’t remove it.
The label is weather-resisting and will still be legible if it has been exposed to the open air for a longer time.
Helical fittings are largely protected by patents or registration of designs.
In case that helical fittings are required for applications not specified in this catalogue a specific enquiry is requested.
Helical fittings can be used:
- to tension
- to suspend
- to fix
- to splice
- to repair
- to armor
- to protect against damage at
- to protect against abrasion at
- to reduce stress at
- to mark
- to space
- to damp vibrations
- to pull (installation)
- to shunt weak splices at
- as interphase spacer at
- to rise diameter of
stranded conductors, cables and solid conductors.
Stand: 19. Juni 2006
Pfad: Helical formed fittings/ Introduction/ Introduction in helical fittings/
Gedruckt am: 16. Januar 2012
1 / 53
ONLINE-CATALOGUE
B4/2 Composition of identification numbers
Remark:
Introduction in composition of identification numbers see catalogue sheet B8/8.
Stand: 19. Juni 2006
Pfad: Helical formed fittings/ Introduction/ Composition of identification numbers/
Gedruckt am: 16. Januar 2012
2 / 53
ONLINE-CATALOGUE
B403/1 Helical dead-ends (AB) for solid and stranded copper conductors
1 ..... Helical dead-end
2 ..... Thimble
3 ..... Black crossing mark
Clamping range
Helical rods
Loop
Mass
Thimble
RIBE-Order-No.
AB 026 030
AB 027 031
AB 028 033
AB 030 034
AB 031 035
AB 033 037
AB 034 038
AB 036 039
AB 037 040
AB 039 042
AB 041 042
AB 042 043
AB 044 044
AB 046 045
AB 048 047
AB 050 048
AB 053 049
AB 055 051
AB 057 052
AB 060 053
AB 062 057
AB 065 058
AB 068 061
AB 071 063
AB 074 066
AB 077 067
AB 081 068
AB 084 070
AB 088 071
AB 091 073
AB 095 076
AB 099 078
AB 104 081
AB 108 084
D1
L
S
No. of rods
D2
mm
2,54 - 2,64
2,65 - 2,77
2,78 - 2,89
2,90 - 3,02
3,03 - 3,15
3,16 - 3,30
3,31 - 3,45
3,46 - 3,61
3,62 - 3,76
3,77 - 3,94
3,95 - 4,11
4,12 - 4,29
4,30 - 4,47
4,48 - 4,67
4,68 - 4,88
4,89 - 5,08
5,09 - 5,31
5,32 - 5,54
5,55 - 5,77
5,78 - 6,02
6,03 - 6,27
6,28 - 6,55
6,56 - 6,83
6,84 - 7,14
7,15 - 7,44
7,45 - 7,77
7,78 - 8,10
8,11 - 8,46
8,47 - 8,81
8,82 - 9,19
9,20 - 9,58
9,59 - 9,98
9,99 - 10,41
10,42 - 10,85
mm
300
310
330
340
350
370
380
390
400
420
420
430
440
450
470
480
490
510
520
530
570
580
610
630
660
675
680
700
710
730
760
780
810
840
mm
1,62
1,62
1,48
1,48
1,48
1,48
1,48
1,62
1,62
1,62
1,48
1,48
1,48
1,62
1,62
1,62
1,83
1,83
1,83
1,83
2,18
2,18
2,18
2,39
2,39
2,59
2,59
2,89
2,89
2,89
2,89
3,25
3,25
3,25
mm
3
3
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
mm
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
Stand: 25. November 2010
Pfad: Helical formed fittings/ Helical dead ends/ Helical dead-ends (AB) for solid and stranded copper conductors/
Gedruckt am: 16. Januar 2012
RIBE-No.
kg/ 100 pieces
3,6
3,8
4,4
4,5
4,7
4,9
5,1
6,3
6,4
6,7
7,0
7,2
7,3
9,0
9,4
9,6
12,5
13,0
13,3
13,5
20,7
21,0
22,1
27,4
28,7
34,3
34,8
44,6
45,2
46,5
48,4
62,7
65,2
67,6
F 2684/3
3 / 53
ONLINE-CATALOGUE
Clamping range
Helical rods
Loop
Mass
Thimble
RIBE-Order-No.
AB 112 085
AB 116 086
AB 121 087
AB 125 089
AB 129 094
AB 132 095
AB 136 096
AB 140 097
AB 144 099
AB 150 101
AB 157 105
AB 163 108
AB 170 114
AB 177 118
AB 185 122
AB 192 129
AB 200 134
AB 209 137
AB 217 146
AB 227 150
D1
L
S
No. of rods
D2
mm
10,86 - 11,25
11,26 - 11,66
11,67 - 12,10
12,11 - 12,57
12,58 - 12,90
12,91 - 13,28
13,29 - 13,67
13,68 - 14,07
14,08 - 14,48
14,49 - 15,09
15,10 - 15,72
15,73 - 16,38
16,39 - 17,07
17,08 - 17,78
17,79 - 18,52
18,53 - 19,28
19,29 - 20,09
20,10 - 20,93
20,94 - 21,79
21,80 - 22,71
mm
850
860
870
890
940
950
960
970
990
1010
1050
1080
1140
1180
1220
1290
1340
1370
1460
1500
mm
3,66
3,66
3,66
3,66
3,66
3,66
3,66
3,66
3,66
4,11
4,11
4,11
4,62
4,62
4,62
5,18
5,18
5,18
5,82
5,82
mm
5
5
5
5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
mm
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
58
RIBE-No.
kg/ 100 pieces
86,7
87,8
88,8
90,8
115,1
116,3
117,5
118,8
121,2
155,9
162,1
166,7
222,5
230,2
238,1
316,4
328,6
336,1
452,1
464,4
F 2685/3
Material:
Helical rods: Copper alloy
Application:
Helical dead-ends (AB) can be used for full load tensioning of solid and stranded copper-conductors together with clevis thimbles (see page B821).Thimbles have to be
ordered separately.
Please state if dead-ends for left-hand lay conductors are required.
The dead-ends are furnished bent as loops with the rods glued together to a bundle. The inside surfaces are gritted.
A coloured cross-over mark near the loop indicates the starting point of application.
Attention! They lay direction of both the dead-ends and the outer layer of the conductor must be the same.
Mounting instruction:
See mounting instruction no. 9
Stand: 25. November 2010
Pfad: Helical formed fittings/ Helical dead ends/ Helical dead-ends (AB) for solid and stranded copper conductors/
Gedruckt am: 16. Januar 2012
4 / 53
ONLINE-CATALOGUE
B404/1 Helical dead-ends (AG) for solid and stranded hot dip galvanized steel conductors and glass fiber rods
1 ..... Helical dead-end
2 ..... Thimble
3 ..... Black crossing mark
RIBE-Order-No.
AG 026 025
AG 027 026
AG 029 028
AG 030 029
AG 032 030
AG 033 033
AG 035 035
AG 036 038
AG 038 040
AG 040 043
AG 041 044
AG 044 046
AG 046 048
AG 048 052
AG 050 052
AG 052 053
AG 054 055
AG 056 056
AG 059 057
AG 062 061
AG 064 062
AG 067 064
AG 070 066
AG 073 067
AG 076 069
AG 079 071
AG 082 074
AG 085 076
AG 089 077
AG 093 079
AG 096 081
AG 100 084
AG 104 086
AG 108 088
AG 111 089
Clamping range
D1
L
mm
2,54 - 2,64
2,65 - 2,77
2,78 - 2,90
2,91 - 3,05
3,06 - 3,20
3,21 - 3,35
3,36 - 3,50
3,51 - 3,66
3,67 - 3,84
3,85 - 4,01
4,02 - 4,19
4,20 - 4,40
4,41 - 4,60
4,61 - 4,80
4,81 - 5,00
5,01 - 5,23
5,24 - 5,46
5,47 - 5,69
5,70 - 5,94
5,95 - 6,20
6,21 - 6,45
6,46 - 6,73
6,74 - 7,01
7,02 - 7,32
7,33 - 7,62
7,63 - 7,95
7,96 - 8,28
8,29 - 8,58
8,59 - 8,95
8,96 - 9,30
9,31 - 9,68
9,69 - 10,06
10,07 - 10,45
10,46 - 10,80
10,81 - 11,10
mm
250
250
260
270
290
300
310
310
330
350
360
410
480
500
500
500
520
530
540
580
590
610
660
630
650
710
740
760
770
790
810
840
860
880
890
Helical rods
S
mm
1,30
1,30
1,30
1,30
1,30
1,55
1,55
1,55
1,55
1,78
1,78
1,78
2,18
2,18
2,18
1,78
1,78
1,78
1,78
2,18
2,18
2,18
2,18
2,54
2,54
2,54
2,54
3,02
3,02
2,54
2,54
3,02
3,02
3,02
3,02
Loop
D2
Mass
No. of rods
3
3
3
4
4
4
4
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
5
5
6
6
mm
38
38
38
38
38
38
38
38
38
38
38
38
44
44
44
44
44
44
44
44
44
44
50
50
50
50
50
50
50
50
50
50
50
64
64
kg/ 100 pieces
1,9
2,0
2,1
2,7
2,9
4,3
4,3
4,3
4,6
6,3
6,5
7,7
13,0
13,6
13,6
11,2
11,7
11,9
12,1
19,6
20,0
20,7
22,3
28,5
29,4
32,1
33,4
48,2
48,8
42,8
43,9
53,2
54,5
66,9
67,7
Stand: 08. Mai 2007
Pfad: Helical formed fittings/ Helical dead ends/ Helical dead-ends (AG) for solid and stranded hot dip galvanized steel conductors and glass fiber rods/
Gedruckt am: 16. Januar 2012
Thimble
RIBE-No.
F 2684/3
5 / 53
ONLINE-CATALOGUE
RIBE-Order-No.
AG 114 090
AG 117 091
AG 120 094
AG 125 100
AG 130 102
AG 135 104
AG 139 107
AG 145 119
AG 151 122
AG 157 124
AG 163 127
AG 168 129
Clamping range
D1
L
mm
11,11 - 11,45
11,46 - 11,75
11,76 - 12,05
12,06 - 12,55
12,56 - 13,05
13,06 - 13,50
13,51 - 13,94
13,95 - 14,53
14,54 - 15,15
15,16 - 15,75
15,76 - 16,36
16,37 - 16,80
mm
900
910
940
1000
1020
1040
1070
1190
1220
1240
1270
1290
Helical rods
S
mm
3,02
3,51
3,51
3,51
3,51
4,04
4,04
4,04
4,04
4,37
4,37
4,37
Loop
D2
Mass
No. of rods
6
5
5
6
6
5
5
6
6
6
6
6
mm
64
64
64
64
64
64
64
64
64
64
64
64
kg/ 100 pieces
68,4
71,5
80,1
120,0
104,0
118,0
122,0
162,0
166,0
197,0
202,0
205,0
Thimble
RIBE-No.
F 2685/3
Material:
Helical rods: Steel, h.d.g. (inside surfaces gritted)
Application:
Helical dead-ends (AG) can be used for full load tensioning of solid and stranded hot dip galvanized steel-conductors and glass fiber rods. Check the breaking load of clevis
thimbles (see page B821). Thimbles have to be ordered separately.
Please state if dead-ends for left-hand lay conductors are required.
The dead-ends are furnished bent as loops with the rods glued together to a bundle.The inside surfaces are gritted.
A coloured cross-over mark near the loop indicates the starting point of application.
Attention! They lay direction of both the dead-ends and the outerlayer of the conductor must be the same.
Mounting instruction:
See mounting instruction no. 9
Stand: 08. Mai 2007
Pfad: Helical formed fittings/ Helical dead ends/ Helical dead-ends (AG) for solid and stranded hot dip galvanized steel conductors and glass fiber rods/
Gedruckt am: 16. Januar 2012
6 / 53
ONLINE-CATALOGUE
B405/1 Helical dead-ends (AH) for stainless steel conductors and glass fiber rods
1 ..... Helical dead-end
2 ..... Thimble
3 ..... Black crossing mark
RIBE-Order-No.
AH 050 052
AH 056 037 *)
AH 059 058s *)
AH 062 061s
AH 070 066
AH 079 071
AH 089 058 *)
AH 093 092
AH 101 070
AH 117 091
AH 121 081
Clamping range
D1
mm
4,81 - 5,00
5,01 - 5,69
5,70 - 5,94
5,95 - 6,20
6,74 - 7,01
7,63 - 7,95
8,61 - 8,92
8,93 - 9,32
9,74 - 10,14
11,46 - 11,75
11,76 - 12,16
L
mm
520
380
580
610
660
710
580
920
705
910
810
Helical rods
S
No. of
mm
rods
2,03
2,03
2,03
2,56
2,18
2,56
3,05
3,05
3,05
3,53
3,53
4
5
5
4
5
5
5
5
5
5
5
Loop
D2
44
50
50
44
50
50
50
58
50
64
64
Mass.
Thimble
RIBE-No.
kg/ 100 pcs
11,6
10,7
15,2
22,0
21,0
31,0
36,7
54,0
44,0
75,0
68,7
F 2684/3
F 2685/3
*) only for glass fiber rods
Material:
Helical rods: Stainless steel (inside surfaces gritted)
Application:
Helical dead-ends (AH) can be used for full load tensioning of stranded stainless steel conductors and glass fiber rods.
Check the breaking load of clevis thimbles (see page B821). Thimbles have to be ordered separately.
Please state if dead-ends for left-hand lay conductors are required.
The dead-ends are furnished bent as loops with the rods glued together to a bundle. The inside surfaces are gritted.
A coloured cross-over mark near the loop indicates the starting point of application.
Attention! They lay direction of both the dead-ends and the outerlayer of the conductor must be the same.
Mounting instruction:
See mounting instruction no. 9
Stand: 10. August 2006
Pfad: Helical formed fittings/ Helical dead ends/ Helical dead-ends (AH) for stainless steel conductors and glass fiber rods/
Gedruckt am: 16. Januar 2012
7 / 53
ONLINE-CATALOGUE
B406/1 Helical dead-ends (AW) for Alumoweld conductors and ACSR
Remark:
See catalogue sheet B811
Stand: 10. August 2006
Pfad: Helical formed fittings/ Helical dead ends/ Helical dead-ends (AW) for Alumoweld conductors and ACSR/
Gedruckt am: 16. Januar 2012
8 / 53
ONLINE-CATALOGUE
B408/1 Thimbles
Remark:
See catalogue sheet B821.
Stand: 10. August 2006
Pfad: Helical formed fittings/ Helical dead ends/Thimbles/
Gedruckt am: 16. Januar 2012
9 / 53
ONLINE-CATALOGUE
B411/1 Armour grip suspensions without attachment for shunts
Remark:
See catalogue sheet B801/3.
Stand: 10. August 2006
Pfad: Helical formed fittings/ Armour grip suspensions/ Armour grip suspensions without attachment for shunts/
Gedruckt am: 16. Januar 2012
10 / 53
ONLINE-CATALOGUE
B411/3 Armour grip suspensions with attachment for shunts
Remark:
See catalogue sheet B801/4.
Stand: 10. August 2006
Pfad: Helical formed fittings/ Armour grip suspensions/ Armour grip suspensions with attachment for shunts/
Gedruckt am: 16. Januar 2012
11 / 53
ONLINE-CATALOGUE
B421/1 Line splices (VAG) for ACSR and AACSR conductors with 2 layers
Fig. 2: Mounting of aluminium splice
Fig.1: Mounting of steel splice
S1 ..... Steel splice
S2 ..... Aluminium splice
1 ....... Steel core
2 ....... Aluminium outer layer
3 ....... Colored center mark
RIBE-Order-No.
Nominal cross section
Type of helical rods
Fig.
mm²
VAG 054 079
16/2,5
VAG 068 096
25/4
VAG 112 168
44/32
VAG 117 168
50/30
VAG 160 224
95/55
VAG 175 265
105/75
VAG 180 251
120/70
Steel splice
Aluminium splice
Steel splice
Aluminium splice
Steel splice
Aluminium splice
Steel splice
Aluminium splice
Steel splice
Aluminium splice
Steel splice
Aluminium splice
Steel splice
Aluminium splice
1
2
1
2
1
2
1
2
1
2
1
2
1
2
L
mm
350
790
400
960
610
1680
660
1680
840
2240
1200
2650
940
2510
D
mm
1,78
2,18
2,18
2,38
1,78
3,45
2,18
3,45
3,02
4,24
3,02
5,18
3,51
5,18
Helical rods
No. of rods
Weight
Rods per subset
kg/ 100 pieces
5
9
6
10
13
11
11
11
11
13
12
11
10
12
2-3
3-3-3
2-2-2
5-5
4-4-5
3-4-4
3-4-4
3-4-4
3-4-4
4-4-5
4-4-4
3-4-4
3-3-4
4-4-4
10,7
18,2
68,8
67,3
179,6
272,0
266,9
Material:
Splice for steel core: Steel/ h.d.g. (blue mark, inside surfaces gritted)
Filler splice: Aluminium alloy (black mark, non-gritted)
Splice for aluminium: Aluminium alloy (green mark, inside surfaces gritted)
Application:
Line splices VAG are used as full tension splices for connecting ACSR or AACSR (see remark) conductors.
Line splices consist of 2 to 4 sets of spirals, coloured differently:
- splice for steel core
- if necessary 1 or 2 filler spirals to fill the gap between diameter of steel splice and outer diameter of conductor
- splice for aluminium layers
The sets with same marking belong together:
Stand: 07. Juli 2008
Pfad: Helical formed fittings/ Line splices/ Line splices (VAG) for ACSR and AACSR conductors with 2 layers/
Gedruckt am: 16. Januar 2012
12 / 53
ONLINE-CATALOGUE
Attention! The lay direction of the line spices has to be equal the lay direction of the outside cable layer.
For repair purpose you also can use line splices in parts (e. g. use only the green marked splice for aluminium).
Mounting instruction:
1.
Straighten the ends of the conductor, tie them together and cut them off straight-line.
2.
Uncover the steel core by removing the aluminium strands at liberally half the length of the line splice for the steel core (blue mark).
Attention: do not damage the steel core.
3.
Tie the ends of the steel core and the aluminium strands together securely.
4.
Clean the aluminium strands at both ends at liberally half the length of the green marked line splice for the aluminium coat. For this purpose we recommend using
a wire scratch brush, e.g. according to sheet B198/1.
5.
Mounting the line splice
Place the first set of rods of the steel core line splice (blue mark) with the colour mark at the end of the steel of one conductor and coil it up.
6.
Mounting becomes easier when you start coiling up the set with some distance from the end of the steel core. However you have to pay attention that the set’s
blue mark is in accordance with the end of the steel core after coiling up.
Place the end of the steel core of the second conductor on the centre mark of the rod set and coil it up as well.
There should be a small air gap between the ends of the steel cores.
Coil up the remaining sets as well, in the same way, starting near the steel core joint.
If the sets consist of an unequal number of rods, the set with the smallest number of rods should be coiled up at last.
The filler rods (black mark) have to be coiled up the same way.
The blue and the black marks have to align with each other.
If there is a difference in diameter between the steel core and the aluminium outside layer it is necessary to attach two filler rods according to the indications in
the table.
with a rod diameter of ≤ 6,35 mm for the line splice for the aluminium coat
Place the first set of rods starting from the conductor joint in a way that the green and the black mark align with each other.
Coil up the set on one side, and on the other side subsequently. Place the second set close to the first one and coil it up onto the conductor in a parallel way to
the first set.
The same procedure has to be carried out with the remaining sets.
with a rod diameter of ≥ 7,87 mm for the line splice for the aluminium coat
Apply a thin but closed layer of the antifriction paste on the conductor surface. The antifriction paste can be applied by hand or with a paint brush.
Place the first rod with the green mark on the black mark of the filler rod and coil it up on one side and after that on the other side. The same procedure has to be
carried out with the remaining rods, whereas the rods have to be close to each other.
Cleaning the line splice. For this purpose we recommend using a wire scratch brush, e.g. according to sheet B198/1.
Dismantling:
Removal and subsequent reuse are not allowed.
Remark:
For applying at AACSR please contact the company.
Stand: 07. Juli 2008
Pfad: Helical formed fittings/ Line splices/ Line splices (VAG) for ACSR and AACSR conductors with 2 layers/
Gedruckt am: 16. Januar 2012
13 / 53
ONLINE-CATALOGUE
B421/2 Line splices (VAG) for ACSR and AACSR conductors with 3 or 4 layers
Fig. 1: Mounting of steel splice
Fig. 2: Mounting of filler splice
Fig. 3: Mounting of aluminium splice
S1 ..... Steel splice
S2 ..... Filler splice
S3 ..... Aluminium splice
1 ....... Steel core
2 ....... Aluminium inner layer
3 ....... Aluminium outer layer
4 ....... Colored center mark
RIBE-Order-No.
Nominal cross section
Type of spiral
Fig.
mm²
VAG081114
35/6
VAG090132
42/7
VAG096119
50/8
67,43/11,28
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
1
2
3
1
2
3
1
2
3
1
L
mm
410
410
1140
300
300
1320
330
330
1190
410
D
mm
1,30
1,30
2,59
1,30
1,82
2,59
1,30
1,83
3,07
1,78
Stand: 06. Dezember 2010
Pfad: Helical formed fittings/ Line splices/ Line splices (VAG) for ACSR and AACSR conductors with 3 or 4 layers/
Gedruckt am: 16. Januar 2012
Helical rods
No. of rods
Weight
Rods per subset
kg/ 100 pieces
7
13
11
8
10
12
8
11
11
8
3-4
4-4-5
3-4-4
4-4
5-5
4-4-4
4-4
3-4-4
3-4-4
4-4
27,0
30,0
32,9
14 / 53
ONLINE-CATALOGUE
RIBE-Order-No.
Nominal cross section
VAG113140
mm²
66,27/11,04
Quail,d=11,34mm
VAG117162
70/12
VAG136190
95/15
VAG145200
110/22
Hyena,d=14,57mm
VAG155216
120/20
VAG161231
125/30
VAG163224
135/22
Partridge,d=16,28mm
VAG171244
150/25
VAG189272
170/40
VAG190282
185/30
VAG203289
210/35
VAG210275
230/30
VAG210302
210/50
VAG219305
240/40
VAG225310
265/35
VAG245325
300/50
VAG205345
340/30
VAG266390
310/100
VAG266429
360/60
VAG267390
385/35
VAG270425
380/50
VAG280482
340/110
VAG288432
435/55
Type of spiral
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice 2
Filler splice 1
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice 2
Filler splice 1
Aluminium splice
Steel splice
Filler splice 2
Filler splice 1
Aluminium splice
Steel splice
Filler splice
Aluminium splice
Steel splice
Filler splice 2
Filler splice 1
Fig.
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
2
3
1
2
3
1
2
3
1
2
2
3
1
2
2
3
1
2
3
1
2
2
L
mm
410
1400
430
430
1620
457
457
1900
530
530
2000
530
530
2160
606
660
2310
610
610
2240
630
630
2440
760
760
2720
680
680
2820
700
700
2890
630
630
2750
790
790
3020
736
736
3050
710
710
3100
790
790
3250
710
710
710
3450
1100
1100
3900
1040
1040
4290
710
710
710
3900
840
840
840
4250
1420
1420
4820
860
860
860
D
mm
1,82
3,45
1,78
1,83
3,45
1,78
2,39
4,24
1,78
2,38
4,62
1,78
3,07
4,24
2,18
2,38
4,24
1,78
3,07
4,62
2,18
3,07
5,18
3,02
2,38
5,18
2,54
3,45
6,35
2,54
3,71
6,35
2,18
4,24
6,35
2,54
3,45
6,35
2,54
4,24
6,35
2,54
4,24
6,35
2,54
5,18
6,35
2,54
3,07
3,07
7,87
3,56
3,07
7,87
3,02
5,18
7,87
2,54
3,07
3,70
7,87
2,54
3,07
3,71
7,87
4,04
3,07
7,87
3,02
3,07
3,45
Stand: 06. Dezember 2010
Pfad: Helical formed fittings/ Line splices/ Line splices (VAG) for ACSR and AACSR conductors with 3 or 4 layers/
Gedruckt am: 16. Januar 2012
Helical rods
No. of rods
13
11
8
14
11
9
12
11
11
12
11
11
11
12
11
15
13
11
11
12
10
12
11
9
18
12
10
12
11
10
12
11
10
10
11
12
13
11
11
11
12
10
11
12
12
10
13
10
13
18
10
12
20
12
11
11
12
10
14
16
12
12
14
16
12
11
22
12
11
16
20
Weight
Rods per subset
4-4-5
3-4-4
4-4
3-3-4-4
3-4-4
3-3-3
4-4-4
3-3-3
3-4-4
4-4-4
3-4-4
3-4-4
3-4-4
4-4-4
3-4-4
5-5-5
4-4-5
3-4-4
3-4-4
4-4-4
5-5
4-4-4
3-4-4
3-3-3
4-4-5-5
4-4-4
5-5
4-4-4
3-4-4
5-5
4-4-4
3-4-4
3-3-4
3-3-4
3-4-4
4-4-4
4-4-5
3-3-4
3-4-4
3-4-4
4-4-4
5-5
3-4-4
3-3-3-3
4-4-4
3-3-4
4-4-5
5-5
3-3-3-4
4-4-5-5
*)
3-3-3-3
5-5-5-5
*)
3-4-4
3-4-4
*)
5-5
3-3-4-4
4-4-4-4
*)
4-4-4
4-5-5
4-4-4-4
*)
3-4-4
4-4-4-5-5
*)
3-4-4
4-4-4-4
5-5-5-5
kg/ 100 pieces
60,0
61,6
103,3
128,0
133,5
162,7
165,0
204,3
264,0
342,7
355,5
337,0
380,6
411,0
403,0
476,7
603,0
819,0
850,0
711,0
829,3
1048,0
864,7
15 / 53
ONLINE-CATALOGUE
RIBE-Order-No.
Nominal cross section
Type of spiral
Fig.
Helical rods
Weight
L
D
No. of rods
Rods per subset
mm²
mm
mm
kg/ 100 pieces
Aluminium splice
3
4320 7,87
12
*)
Steel splice
1
890
3,07
11
3-4-4
VAG306460
490/65
Filler splice 2
2
890
3,45
14
4-5-5
990,9
Filler splice 1
2
890
3,71
18
4-4-5-5
Aluminium splice
3
4600 7,87
13
*)
Steel splice
1
790
2,54
12
4-4-4
VAG322480
560/50
Filler splice 2
2
790
3,07
14
4-5-5
1274,4
Filler splice 1
2
790
6,35
11
3-4-4
Aluminium splice
3
4800 9,27
12
*)
Steel splice
1
960
3,02
12
4-4-4
VAG328530
564/72
Filler splice 2
2
962
3,45
14
4-5-5
1420,0
Finch
Filler splice 1
2
960
4,62
15
5-5-5
Aluminium splice
3
5300 9,27
12
*)
Steel splice
1
1040 3,51
11
3-4-4
VAG361532
680/83, 680/85,
Filler splice 2
2
1040 3,45
16
4-4-4-4
1590,0
685/87
Filler splice 1
2
1040 5,18
16
4-4-4-4
Aluminium splice
3
5320 9,27
13
*)
*) Armor splices consist of single rods with antifriction paste. The paste has to be applicated to the surface of the conductor at installation location. The antifriction paste is part of delivery.
Material:
Splice for steel core: Steel/ h.d.g. (blue mark, inside surfaces gritted)
Filler splice: Aluminium alloy (black mark, non-gritted)
Splice for aluminium: Aluminium alloy (green mark, inside surfaces gritted)
Application:
Line splices VAG are used as full tension splices for connecting ACSR or AACSR (see remark) conductors.
Line splices consist of 2 to 4 sets of spirals, coloured differently:
- splice for steel core
- if necessary 1 or 2 filler spirals to fill the gap between diameter of steel splice and outer diameter of conductor
- splice for aluminium layers
The sets with same marking belong together:
Attention! The lay direction of the line spices has to be equal the lay direction of the outside cable layer.
For repair purpose you also can use line splices in parts (e. g. use only the green marked splice for aluminium).
Mounting instruction:
1.
Straighten the ends of the conductor, tie them together and cut them off straight-line.
2.
Uncover the steel core by removing the aluminium strands at liberally half the length of the line splice for the steel core (blue mark).
Attention: do not damage the steel core.
3.
Tie the ends of the steel core and the aluminium strands together securely.
4.
Clean the aluminium strands at both ends at liberally half the length of the green marked line splice for the aluminium coat. For this purpose we recommend using
a wire scratch brush, e.g. according to sheet B198/1.
5.
Mounting the line splice
Place the first set of rods of the steel core line splice (blue mark) with the colour mark at the end of the steel of one conductor and coil it up.
Mounting becomes easier when you start coiling up the set with some distance from the end of the steel core. However you have to pay attention that the set’s
blue mark is in accordance with the end of the steel core after coiling up.
Place the end of the steel core of the second conductor on the centre mark of the rod set and coil it up as well.
There should be a small air gap between the ends of the steel cores.
Coil up the remaining sets as well, in the same way, starting near the steel core joint.
If the sets consist of an unequal number of rods, the set with the smallest number of rods should be coiled up at last.
The filler rods (black mark) have to be coiled up the same way.
The blue and the black marks have to align with each other.
If there is a difference in diameter between the steel core and the aluminium outside layer it is necessary to attach two filler rods according to the indications in
the table.
with a rod diameter of ≤ 6,35 mm for the line splice for the aluminium coat
Place the first set of rods starting from the conductor joint in a way that the green and the black mark align with each other.
Coil up the set on one side, and on the other side subsequently. Place the second set close to the first one and coil it up onto the conductor in a parallel way to
the first set.
The same procedure has to be carried out with the remaining sets.
with a rod diameter of ≥ 7,87 mm for the line splice for the aluminium coat
Apply a thin but closed layer of the antifriction paste on the conductor surface. The antifriction paste can be applied by hand or with a paint brush.
Place the first rod with the green mark on the black mark of the filler rod and coil it up on one side and after that on the other side. The same procedure has to be
carried out with the remaining rods, whereas the rods have to be close to each other.
Stand: 06. Dezember 2010
Pfad: Helical formed fittings/ Line splices/ Line splices (VAG) for ACSR and AACSR conductors with 3 or 4 layers/
Gedruckt am: 16. Januar 2012
16 / 53
ONLINE-CATALOGUE
6.
Cleaning the line splice. For this purpose we recommend using a wire scratch brush, e.g. according to sheet B198/1.
Dismantling:
Removal and subsequent reuse are not allowed.
Remark:
For applying at AACSR please contact the company.
Stand: 06. Dezember 2010
Pfad: Helical formed fittings/ Line splices/ Line splices (VAG) for ACSR and AACSR conductors with 3 or 4 layers/
Gedruckt am: 16. Januar 2012
17 / 53
ONLINE-CATALOGUE
B422/1 Line splices (VA) for AAC conductors
1 ..... Colored center mark
RIBE-Order-Nor.
Clamping range
D1
Helical rods
L
Dia. of rods
Numbers
mm
mm
mm
VA 040 046
3,92 - 4,09
460
2,18
7
VA 042 048
4,10 - 4,27
480
2,18
7
VA 044 048
4,28 - 4,47
480
2,18
8
VA 046 053
4,49 - 4,67
530
2,18
8
VA 049 053
4,68 - 4,90
530
2,18
8
VA 051 053
4,91 - 5,13
530
2,18
8
VA 053 056
5,14 - 5,38
560
2,18
9
VA 055 056
5,39 - 5,56
560
2,18
9
VA 057 058
5,57 - 5,79
580
2,18
9
VA 060 061
5,80 - 6,07
610
2,18
10
VA 062 063
6,08 - 6,25
630
2,39
9
VA 065 066
6,26 - 6,53
660
2,39
9
VA 068 066
6,57 - 6,86
660
2,39
10
VA 071 068
6,87 - 7,11
680
2,39
10
VA 073 071
7,12 - 7,34
710
2,39
10
VA 075 071
7,35 - 7,57
710
2,39
11
VA 078 076
7,58 - 7,87
760
2,59
10
VA 082 079
7,88 - 8,26
790
2,59
11
VA 086 079
8,27 - 8,64
790
2,59
11
VA 089 084
8,65 - 8,92
840
2,59
11
VA 093 086
8,93 - 9,32
860
2,59
12
VA 096 096
9,33 - 9,66
960
3,07
10
VA 101 096
9,67 - 10,11
960
3,07
11
VA 104 096
10,12 - 10,49
960
3,07
11
VA 107 102
10,50 - 10,79
1020
3,07
12
VA 112 104
10,80 - 11,25
1040
3,45
11
VA 117 107
11,26 - 11,74
1070
3,45
11
VA 122 117
11,75 - 12,25
1170
3,45
12
VA 127 117
12,26 - 12,78
1170
3,71
11
VA 132 119
12,79 - 13,23
1190
3,71
12
VA 138 129
13,24 - 13,83
1290
4,24
11
VA 144 132
13,84 - 14,40
1320
4,24
11
VA 150 155
14,41 - 15,09
1550
4,62
11
VA 157 160
15,10 - 15,70
1600
4,62
11
VA 163 170
15,71 - 16,36
1700
4,62
12
VA 170 175
16,37 - 17,04
1750
5,18
11
VA 177 178
17,05 - 17,78
1780
5,18
11
VA 185 195
17,79 - 18,52
1950
6,35
10
VA 193 201
18,53 - 19,30
2010
6,35
10
VA 201 211
19,31 - 20,12
2110
6,35
11
VA 209 213
20,13 - 20,96
2130
6,35
11
VA 215 218
20,97 - 21,59
2180
6,35
11
VA 225 251
21,60 - 22,50
2510
6,35
12
VA 236 268
22,51 - 23,60
2680
7,87
10
VA 245 274
23,61 - 24,59
2740
7,87
11
VA 254 282
24,60 - 25,42
2820
7,87
11
VA 266 307
25,43 - 26,67
3070
7,87
11
VA 277 322
26,68 - 27,71
3220
7,87
12
VA 288 348
27,72 - 28,86
3480
9,27
11
VA 300 358
28,87 - 30,05
3580
9,27
11
VA 312 363
30,06 - 31,29
3630
9,27
11
VA 339 378
31,30 - 33,99
3780
9,27
12
*) Armor splices consist of single rods with antifriction paste. The paste has to be applicated to the surface of the conductor at installaion location.
Stand: 16. April 2010
Pfad: Helical formed fittings/ Line splices/ Line splices (VA) for AAC conductors/
Gedruckt am: 16. Januar 2012
Mass
Rods per subset
3-4
3-4
4-4
4-4
4-4
4-4
3-3-3
3-3-3
3-3-3
5-5
3-3-3
3-3-3
5-5
5-5
5-5
3-4-4
5-5
3-4-4
3-4-4
3-4-4
4-4-4
3-3-4
3-4-4
3-4-4
4-4-4
3-4-4
3-4-4
4-4-4
3-4-4
4-4-4
3-4-4
3-4-4
3-4-4
3-4-4
4-4-4
3-4-4
3-4-4
3-3-4
3-3-4
3-4-4
3-4-4
3-4-4
4-4-4
*)
kg / 100 pieces
3,6
3,7
4,2
4,5
4,6
4,7
5,6
5,6
5,8
6,7
7,5
7,8
8,7
9,0
9,4
10,3
11,9
13,6
13,6
14,4
16,1
23,1
23,1
23,1
26,7
31,6
32,5
38,8
41,0
45,5
59,0
60,3
84,2
86,9
101,0
119,4
121,5
181,8
187,4
216,3
220,4
223,6
280,7
383,7
431,4
444,0
483,4
553,0
761,0
782,3
793,0
901,0
18 / 53
ONLINE-CATALOGUE
Materials:
Rods made of aluminium alloy, the inside surface of the rod sets is gritted up to D1 = 22,5 mm.
Application:
Line splices VA are used as full tension splices for AAC conductors. For ACSR and AACSR conductors they can be usred as non-tension splices.
The line splices with rod dia. ≤ 6,35 mm are delivered in premounted rod sets. The contact surface of the rod sets is gritted. All line splices with a rod dia. ≥ 7,87 mm are
delivered as single rods. Friction paste has to be applied to the conductor surface before installation. All line splices have a centre marking.
Important! The lay direction of the line spices has to equal the lay direction of the outer conductor layer.
Mounting instructions:
1) Straighten the conductor ends to be jointed, secure the conductor wires in their proper position and cut the conductor ends so that they have a level surface.
2) Clean the conductor ends over at least the contact length of the line splice. For this purpose we recommend using a steel wire brush, e.g. according to sheet B198/1.
3) Mounting the line splice
3.1) with a rod diameter of ≤ 6,35 mm
Place the first set of rods with the colour mark at one conductor end and wrap it on. Position the end of the
second conductor at the centre mark of the rod set and wrap it on as well. Wrap on the remaining sets as well, in
the same way, starting near the conductor ends.
3.2) with a rod diameter of ≥ 7,87 mm
Apply a thin but closed layer of the friction paste on the conductor surface along the contact length of the line splice. The friction paste can be applied by hand or with a
paint brush.
Place the first rod with the colour mark at one conductor end and wrap it on. Position the end of the second conductor at the centre mark of the rod and wrap it on as well.
Wrap on the second rod, in the same way, starting near the conductor ends. The second rod must be placed close to the first one. Proceed with the remaining rods in the
same way.
4) Clean the line splice after all rods have been mounted. For this purpose we recommend a steel wire brush, e.g. according to sheet B198/1.
Dismantling:
Reuse after removal is not allowed.
Stand: 16. April 2010
Pfad: Helical formed fittings/ Line splices/ Line splices (VA) for AAC conductors/
Gedruckt am: 16. Januar 2012
19 / 53
ONLINE-CATALOGUE
B422/2 Line splices (VK) for copper wires and stranded copper conductors
1 ..... Colored center mark
RIBE-Order-No.
VK 025 043
VK 026 046
VK 027 046
VK 028 046
VK 029 046
VK 030 051
VK 031 051
VK 032 051
VK 033 051
VK 034 051
VK 036 053
VK 037 056
VK 038 056
VK 039 056
VK 040 056
VK 041 058
VK 042 058
VK 043 063
VK 045 063
VK 046 066
VK 047 066
VK 049 066
VK 050 066
VK 052 068
VK 053 071
VK 055 071
VK 057 076
VK 059 076
VK 061 079
VK 062 081
VK 064 084
VK 066 086
VK 068 089
VK 069 089
VK 071 091
VK 073 094
VK 075 094
VK 077 096
VK 079 096
VK 081 099
VK 084 107
VK 086 109
VK 088 112
Clamping range
D1
L
Rod dia.
Helical rods
Number
Rods per subset
mm
2,46 - 2,54
2,55 - 2,64
2,65 - 2,75
2,76 - 2,84
2,85 - 2,95
2,96 - 3,07
3,08 - 3,18
3,19 - 3,25
3,26 - 3,35
3,36 - 3,48
3,49 - 3,61
3,62 - 3,73
3,74 - 3,81
3,82 - 3,91
3,92 - 4,01
4,02 - 4,19
4,20 - 4,29
4,30 - 4,39
4,40 - 4,55
4,56 - 4,67
4,68 - 4,78
4,79 - 4,93
4,94 - 5,08
5,09 - 5,23
5,24 - 5,38
5,39 - 5,54
5,55 - 5,74
5,75 - 5,97
5,98 - 6,13
6,14 - 6,27
6,28 - 6,47
6,48 - 6,65
6,66 - 6,81
6,82 - 6,98
6,99 - 7,19
7,20 - 7,37
7,38 - 7,57
7,58 - 7,75
7,76 - 7,91
7,92 - 8,15
8,16 - 8,43
8,44 - 8,66
8,67 - 8,87
mm
430
460
460
460
460
510
510
510
510
510
530
560
560
560
560
580
580
630
630
660
660
660
660
680
710
710
760
760
790
810
840
860
890
890
910
940
940
960
960
990
1070
1090
1120
mm
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
1,83
2,06
2,06
2,06
2,06
2,06
2,31
2,31
2,31
2,31
2,31
2,31
2,31
2,31
2,31
2,59
2,59
2,59
6
6
6
6
6
6
7
7
7
7
7
8
8
8
8
8
8
9
9
9
9
9
9
10
9
10
10
10
10
10
11
10
10
10
10
11
11
11
11
11
11
11
11
3-3
3-3
3-3
3-3
3-3
2-2-2
3-4
3-4
3-4
3-4
3-4
4-4
4-4
4-4
4-4
4-4
4-4
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
5-5
5-5
5-5
5-5
5-5
5-5
5-5
3-4-4
5-5
5-5
5-5
5-5
3-4-4
3-4-4
3-4-4
3-4-4
3-4-4
3-4-4
3-4-4
3-4-4
Stand: 08. Mai 2007
Pfad: Helical formed fittings/ Line splices/ Line splices (VK) for copper wires and stranded copper conductors/
Gedruckt am: 16. Januar 2012
Weight
kg/ 100 pieces
6,6
7,1
7,1
7,1
7,1
9,1
9,1
9,1
9,1
9,1
9,5
11,4
11,4
11,4
11,4
11,9
11,9
14,5
14,5
15,2
15,2
15,2
15,2
17,4
18,1
18,1
24,6
24,6
25,6
26,2
30,0
35,0
36,2
36,2
37,0
42,1
42,1
43,0
43,0
44,3
60,2
61,3
63,0
20 / 53
ONLINE-CATALOGUE
RIBE-Order-No.
VK 091112
VK 093 117
VK 096 119
VK 099 122
VK 102 129
VK 105 129
VK 107 132
VK 109 135
VK 111 140
VK 114 142
VK 117 147
VK 121 150
VK 124 152
VK 126 152
VK 130 160
VK 131 162
VK 135 165
VK 137 165
VK 139 165
VK 142 168
VK 146 168
VK 150 175
VK 153 183
VK 158 183
VK 162 190
VK 166 195
VK 170 195
VK 174 203
VK 177 211
VK 181 213
VK 185 218
VK 189 221
VK193 223
VK 196 231
VK 200 239
VK 205 241
VK 209 244
VK 213 249
VK 218 259
VK 221 264
VK 223 269
VK227 274
Clamping range
D1
L
Rod dia.
Helical rods
Number
Rods per subset
Weight
mm
8,88 - 9,14
9,15 - 9,32
9,33 - 9,60
9,61 - 9,93
9,94 - 10,26
10,27 - 10,54
10,55 - 10,71
10,72 - 10,97
10,98 - 11,18
11,19 - 11,48
11,49 - 11,76
11,77 - 12,14
12,15 - 12,44
12,45 - 12,62
12,63 - 13,00
13,01 - 13,18
13,19 - 13,51
13,52 - 13,71
13,72 - 13,97
13,98 - 14,27
14,28 - 14,63
14,64 - 15,01
15,02 - 15,37
15,38 - 15,85
15,86 - 16,23
16,24 - 16,64
16,65 - 17,07
17,08 - 17,40
17,41 - 17,78
17,79 - 18,13
18,14 - 18,54
18,55 - 18,92
18,93 - 19,30
19,31 - 19,68
19,69 - 20,06
20,07 - 20,52
20,53 - 20,95
20,96 - 21,38
21,39 - 21,84
21,85 - 22,10
22,11 - 22,35
22,36 - 22,73
mm
1120
1170
1190
1220
1290
1290
1320
1350
1400
1420
1470
1500
1520
1520
1600
1620
1650
1650
1650
1680
1680
1750
1830
1830
1900
1950
1950
2030
2110
2130
2180
2210
2230
2310
2390
2410
2440
2490
2590
2640
2690
2740
mm
2,59
2,89
2,89
2,89
2,89
2,89
2,89
3,66
3,66
3,66
3,66
3,66
3,66
3,66
3,66
3,66
3,66
3,66
3,66
3,66
3,66
3,66
4,11
4,11
4,11
4,11
4,11
4,62
4,62
4,62
4,62
4,62
4,62
4,62
5,18
5,18
5,18
5,18
5,82
5,82
5,82
5,82
11
11
11
11
12
12
12
10
10
10
11
11
11
11
12
12
12
12
12
13
13
13
12
12
13
13
13
12
12
13
13
13
13
14
13
13
13
13
12
12
13
13
3-4-4
3-4-4
3-4-4
3-4-4
4-4-4
4-4-4
4-4-4
3-3-4
3-3-4
3-3-4
3-4-4
3-4-4
3-4-4
3-4-4
4-4-4
4-4-4
4-4-4
4-4-4
4-4-4
4-4-5
4-4-5
4-4-5
4-4-4
4-4-4
4-4-5
4-4-5
4-4-5
4-4-4
4-4-4
4-4-5
4-4-5
4-4-5
4-4-5
4-5-5
3-3-3-4
3-3-3-4
3-3-3-4
3-3-3-4
3-3-3-3
3-3-3-3
3-3-3-4
3-3-3-4
kg/ 100 pieces
63,0
82,0
83,4
85,5
98,6
98,6
101,0
137,8
142,9
144,9
165,1
168,4
171,0
171,0
195,9
198,4
202,0
202,0
202,0
222,8
222,8
232,2
282,5
282,5
317,7
326,2
326,2
396,2
411,8
450,4
461,0
467,3
490,0
526,0
635,0
641,0
649,0
662,0
802,0
818,0
903,0
920,0
Material:
Rods: Copper alloy, inside surfaces gritted
Application:
Line splices VK are used for full tension and current carrying connections between copper conductors (solid or stranded) in the free span. he line splices are centre marked.
Attention! The lay direction of the line spices has to be equal the lay direction of the outside cable layer.
Mounting instruction:
1) Straighten the ends of the conductor, tie them together and cut them off straight-line.
2) Clean the conductor at both ends at liberally half the length of the line splice. For this purpose we recommend using a wire scratch brush, e.g. according to sheet B198/1.
3) Place the first set of rods with the colour mark at the end of one conductor and coil it up. Place the end of the second conductor on the centre mark of the rod set and coil
it up as well. Coil up the remaining sets as well, in the same way, starting near the joint of the conductor’s ends.
4) Clean the line splice. For this purpose we recommend using a wire scratch brush, e.g. according to sheet B198/1.
Stand: 08. Mai 2007
Pfad: Helical formed fittings/ Line splices/ Line splices (VK) for copper wires and stranded copper conductors/
Gedruckt am: 16. Januar 2012
21 / 53
ONLINE-CATALOGUE
Dismantling:
Removal and subsequent reuse of the line splice are not allowed.
Stand: 08. Mai 2007
Pfad: Helical formed fittings/ Line splices/ Line splices (VK) for copper wires and stranded copper conductors/
Gedruckt am: 16. Januar 2012
22 / 53
ONLINE-CATALOGUE
B422/3 Line splices (VG) for hot dip galvanized steel wires and stranded conductors
1 ..... Colored center mark
RIBE-Order-No.
VG 026 038
VG 027 038
VG 029 040
VG 030 043
VG 032 046
VG 033 048
VG 035 051
VG 036 053
VG 038 056
VG 040 058
VG 041 061
VG 044 064
VG 046 066
VG 048 069
VG 050 071
VG 052 071
VG 054 074
VG 056 076
VG 059 079
VG 062 084
VG 064 086
VG 067 089
VG 070 091
VG 073 094
VG 076 096
VG 079 099
VG 082 102
VG 085 109
VG 089 112
VG 093 114
VG 096 117
VG 100 119
VG 104 124
VG 108 135
VG 111 137
VG 114 140
VG 117 142
VG 120 147
VG 125 160
VG 130 162
VG 135 165
VG 139 168
VG 145 183
Clamping range
D1
L
Rod dia.
mm
2,54 - 2,64
2,65 - 2,77
2,78 - 2,90
2,91 - 3,05
3,06 - 3,20
3,21 - 3,35
3,36 - 3,50
3,51 - 3,66
3,67 - 3,84
3,85 - 4,01
4,02 - 4,19
4,20 - 4,40
4,41 - 4,60
4,61 - 4,80
4,81 - 5,00
5,01 - 5,23
5,24 - 5,46
5,47 - 5,69
5,70 - 5,94
5,95 - 6,20
6,21 - 6,45
6,46 - 6,73
6,74 - 7,01
7,02 - 7,32
7,33 - 7,62
7,63 - 7,95
7,96 - 8,28
8,29 - 8,58
8,59 - 8,95
8,96 - 9,30
9,31 - 9,68
9,69 - 10,06
10,07 - 10,45
10,46 - 10,80
10,81 - 11,10
11,11 - 11,45
11,46 - 11,75
11,76 - 12,05
12,06 - 12,55
12,56 - 13,05
13,06 - 13,50
13,51 - 13,94
13,95 - 14,53
mm
380
380
400
430
460
480
510
530
560
580
610
640
660
690
710
710
740
760
790
840
860
890
910
940
960
990
1020
1090
1120
1140
1170
1190
1240
1350
1370
1400
1420
1470
1600
1620
1650
1680
1830
mm
1,30
1,30
1,30
1,30
1,30
1,55
1,55
1,55
1,55
1,78
1,78
1,78
2,18
2,18
2,18
1,78
1,78
1,78
1,78
2,18
2,18
2,18
2,18
2,54
2,54
2,54
2,54
3,02
3,02
2,54
2,54
3,02
3,02
3,02
3,02
3,02
3,51
3,51
3,51
3,51
4,04
4,04
4,04
Helical rods
No. of rods
Stand: 08. Mai 2007
Pfad: Helical formed fittings/ Line splices/ Line splices (VG) for hot dip galvanized steel wires and stranded conductors/
Gedruckt am: 16. Januar 2012
6
8
8
8
8
8
8
8
8
8
8
8
8
8
8
10
10
10
11
10
10
10
11
10
10
10
11
10
10
12
12
11
11
12
12
12
11
11
12
12
11
11
12
Weight
Rods per subset
3-3
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
5-5
5-5
5-5
3-4-4
5-5
5-5
5-5
3-4-4
5-5
5-5
5-5
3-4-4
3-3-4
3-3-4
4-4-4
4-4-4
3-4-4
3-4-4
4-4-4
4-4-4
4-4-4
3-4-4
3-4-4
4-4-4
4-4-4
3-4-4
3-4-4
3-3-3-3
kg/ 100 pieces
2,8
3,8
4,0
4,2
4,5
6,6
7,0
7,3
7,7
10,4
11,0
11,5
17,9
18,7
19,2
16,0
16,7
17,1
19,6
28,4
29,1
30,1
33,9
42,5
43,4
44,7
50,7
69,0
71,0
62,0
63,4
82,9
86,4
102,7
104,2
106,4
133,0
137,7
163,5
165,5
206,0
210,0
249,3
23 / 53
ONLINE-CATALOGUE
RIBE-Order-No.
VG 151 188
VG 157 195
VG 163 201
VG 168 203
VG 190 234
VG 197 239
Clamping range
D1
L
Rod dia.
mm
14,54 - 15,15
15,16 - 15,75
15,76 - 16,36
16,37 - 16,80
18,43 - 19,05
19,06 - 19,71
mm
1880
1950
2010
2030
2340
2390
mm
4,04
4,37
4,04
4,37
4,37
5,18
Helical rods
No. of rods
12
12
12
12
13
12
Weight
Rods per subset
3-3-3-3
3-3-3-3
3-3-3-3
3-3-3-3
3-3-3-4
3-3-3-4
kg/ 100 pieces
256,1
310,0
319,5
322,7
381,0
515,0
Material:
Rods: Steel/ h.d.g. (inside surfaces gritted)
Application:
Line splices VG are used for full tension and current carrying connections between steel conductors (solid or stranded).
For use at suspension points you must ask RIBE.
The sets of splices centre marked.
Attention! The lay direction of the line spices has to be equal the lay direction of the outside cable layer.
Mounting instruction:
1) Straighten the ends of the conductor, tie them together and cut them off straight-line.
2) Clean the conductor at both ends at liberally half the length of the line splice. For this purpose we recommend using a wire scratch brush, e.g. according to sheet B198/1.
3) Place the first set of rods with the colour mark at the end of one conductor and coil it up. Place the end of the second conductor on the centre mark of the rod set and coil
it up as well. Coil up the remaining sets as well, in the same way, starting near the joint of the conductor’s ends.
4) Clean the line splice. For this purpose we recommend using a wire scratch brush, e.g. according to sheet B198/1.
Dismantling:
Removal and subsequent reuse of the line splice are not allowed.
Stand: 08. Mai 2007
Pfad: Helical formed fittings/ Line splices/ Line splices (VG) for hot dip galvanized steel wires and stranded conductors/
Gedruckt am: 16. Januar 2012
24 / 53
ONLINE-CATALOGUE
B431/1 Insulator ties JA...M for post insulators type "Mittelbund", for AAC, AAAC and ACSR conductors
RIBE-Order-No.
JA 055 075 M
JA 057 075 M
JA 060 075 M
JA 062 075 M
JA 065 080 M
JA 068 080 M
JA 071 080 M
JA 073 080 M
JA 075 085 M
JA 078 085 M
JA 082 085 M
JA 086 090 M
JA 089 090 M
JA 093 095 M
JA 096 095 M
JA 101 095 M
JA 104 095 M
JA 107 097 M
JA 112 097 M
JA 117 097 M
JA 122 099 M
JA 127 099 M
JA 132 099 M
JA 138 099 M
JA 144 104 M
JA 150 104 M
JA 159 115 M
JA 163 115 M
JA 170 120 M
JA 177 120 M
JA 185 120 M
JA 193 130 M
JA 201 135 M
JA 209 140 M
Clamping range
D
mm
5,39 - 5,56
5,57 - 5,79
5,80 - 6,07
6,08 - 6,25
6,26 - 6,53
6,54 - 6,86
6,87 - 7,11
7,12 - 7,34
7,35 - 7,57
7,58 - 7,87
7,88 - 8,26
8,27 - 8,64
8,65 - 8,92
8,93 - 9,32
9,33 - 9,66
9,67 - 10,11
10,12 - 10,49
10,50 - 10,79
10,80 - 11,25
11,26 - 11,74
11,75 - 12,25
12,26 - 12,78
12,79 - 13,23
13,24 - 13,82
13,83 - 14,40
14,41 - 15,09
15,10 - 15,90
15,91 - 16,36
16,37 - 17,04
17,05 - 17,78
17,79 - 18,52
18,53 - 19,30
19,31 - 20,12
20,13 - 20,96
L
mm
750
750
750
750
800
800
800
800
850
850
850
900
900
950
950
950
950
970
970
970
990
990
990
990
1040
1040
1150
1150
1200
1200
1200
1300
1350
1400
S
mm
2,18
2,18
2,18
2,18
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
3,07
3,07
3,07
3,07
3,07
3,07
3,07
3,07
4,24
4,24
4,24
4,24
4,24
4,24
4,24
4,24
4,24
4,24
4,24
4,24
4,24
Helical rods
Number of subsets
Rods per subset
Mass
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
4-4
4-4
4-4
4-4
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-5
6-4
6-4
6-4
7-4
7-4
7-4
7-5
8-5
8-5
kg/ 100 pieces
6,6
6,6
6,6
6,6
12,5
12,5
12,5
12,5
13,3
13,3
13,3
14,0
14,0
20,7
20,7
20,7
20,7
21,1
21,1
21,1
21,6
41,1
41,1
41,1
43,2
43,2
47,8
47,8
53,9
53,9
53,9
64,8
74,0
74,0
Material:
Helical rods: Aluminium alloy
Application:
Insulator ties JA...M are used to fix AAC, AAAC and ACSR conductors to post insulators type "Mittelbund" resp. "Schrägbund".
Stand: 08. Mai 2007
Pfad: Helical formed fittings/ Insulator ties/ Insulator ties JA...M for post insulators type \"Mittelbund\", for AAC, AAAC and ACSR conductors/
Gedruckt am: 16. Januar 2012
25 / 53
ONLINE-CATALOGUE
Mounting instruction:
See mounting instruction no. 6
Stand: 08. Mai 2007
Pfad: Helical formed fittings/ Insulator ties/ Insulator ties JA...M for post insulators type \"Mittelbund\", for AAC, AAAC and ACSR conductors/
Gedruckt am: 16. Januar 2012
26 / 53
ONLINE-CATALOGUE
B431/2 Insulator ties JB...M for post insulators type "Mittelbund", for copper and bronze conductors
RIBE-Order-No.
JB 052 076 M
JB 053 076 M
JB 055 076 M
JB 057 076 M
JB 060 076 M
JB 062 076 M
JB 065 080 M
JB 068 080 M
JB 071 080 M
JB 073 080 M
JB 075 085 M
JB 078 085 M
JB 082 085 M
JB 086 094 M
JB 089 094 M
JB 093 094 M
JB 096 094 M
JB 101 097 M
JB 104 097 M
JB 107 097 M
JB 112 102 M
JB 117 102 M
JB 122 109 M
JB 127 109 M
JB 132 109 M
JB 139 115 M
JB 146 115 M
JB 163 115 M
JB 177 120 M
Clamping range
D
mm
5,09 - 5,23
5,24 - 5,38
5,39 - 5,56
5,57 - 5,79
5,80 - 6,07
6,08 - 6,25
6,26 - 6,53
6,54 - 6,86
6,87 - 7,11
7,12 - 7,34
7,35 - 7,57
7,58 - 7,87
7,88 - 8,26
8,27 - 8,64
8,65 - 8,92
8,93 - 9,32
9,33 - 9,66
9,67 - 10,11
10,12 - 10,49
10,50 - 10,79
10,80 - 11,25
11,26 - 11,74
11,75 - 12,25
12,26 - 12,78
12,79 - 13,23
13,24 - 13,97
13,98 - 14,60
15,30 - 16,30
17,05 - 17,78
L
mm
760
760
760
760
760
760
800
800
800
800
850
850
850
940
940
940
940
970
970
970
1020
1020
1090
1090
1090
1150
1150
1150
1200
S
mm
1,83
1,83
1,83
1,83
1,83
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,89
2,89
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
4,11
4,11
3,67
4,11
Helical rods
Number of subsets
Rods per subset
Mass
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
5-5
5-5
5-5
5-5
5-5
4-4
4-4
5-5
5-5
5-5
5-5
5-5
5-5
5-5
3-3
3-3
3-3
3-3
3-3
3-3
4-4
4-4
5-5
6-6
6-6
5-5
5-5
6-4
4-5
kg/ 100 pieces
19,4
19,4
19,4
19,4
19,4
31,1
32,7
40,9
40,9
40,9
43,5
43,5
54,2
59,9
45,4
45,4
45,4
46,8
46,8
46,8
65,7
65,7
87,7
105,2
105,2
145,3
145,3
111,0
166,0
Material:
Helical rods: Copper alloy
Application:
Insulator ties JB...M are used to fix copper and copper alloy (bronze) conductors to post insulators type "Mittelbund" resp. "Schrägbund".
Mounting instruction:
See mounting instruction no. 6
Stand: 08. Mai 2007
Pfad: Helical formed fittings/ Insulator ties/ Insulator ties JB...M for post insulators type \"Mittelbund\", for copper and bronze conductors /
Gedruckt am: 16. Januar 2012
27 / 53
ONLINE-CATALOGUE
B432/1 Insulator ties JA...L for post insulators type "Längsbund", for AAC, AAAC and ACSR conductors
RIBE-Order-No.
JA 055 075 L
JA 057 075 L
JA 060 075 L
JA 062 075 L
JA 065 080 L
JA 068 080 L
JA 071 080 L
JA 073 080 L
JA 075 085 L
JA 078 085 L
JA 082 085 L
JA 086 090 L
JA 089 090 L
JA 093 095 L
JA 096 095 L
JA 101 095 L
JA 104 095 L
JA 107 097 L
JA 112 097 L
JA 117 097 L
JA 122 099 L
JA 127 099 L
JA 132 099 L
JA 138 099 L
JA 144 104 L
JA 150 104 L
Clamping range
D
mm
5,39 - 5,56
5,57 - 5,79
5,80 - 6,07
6,08 - 6,25
6,26 - 6,53
6,54 - 6,86
6,87 - 7,11
7,12 - 7,34
7,35 - 7,57
7,58 - 7,87
7,88 - 8,26
8,27 - 8,64
8,65 - 8,92
8,93 - 9,32
9,33 - 9,66
9,67 - 10,11
10,12 - 10,49
10,50 - 10,79
10,80 - 11,25
11,26 - 11,74
11,75 - 12,25
12,26 - 12,78
12,79 - 13,23
13,24 - 13,82
13,83 - 14,40
14,41 - 15,09
L
mm
750
750
750
750
800
800
800
800
850
850
850
900
900
950
950
950
950
970
970
970
990
990
990
990
1040
1040
S
mm
2,18
2,18
2,18
2,18
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
3,07
3,07
3,07
3,07
3,07
3,07
3,07
3,07
4,24
4,24
4,24
4,24
4,24
Helical rods
Number of subsets
Rods per subset
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
4-4-4
4-4-4
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
Stand: 09. September 2008
Pfad: Helical formed fittings/ Insulator ties/ Insulator ties JA...L for post insulators type \"Längsbund\", for AAC, AAAC and ACSR conductors/
Gedruckt am: 16. Januar 2012
Mass
kg/ 100 pieces
7,5
7,5
7,5
7,5
11,2
11,2
11,2
11,2
11,9
11,9
11,9
12,6
12,6
18,7
18,7
18,7
18,7
19,1
19,1
25,4
25,9
37,0
37,0
37,0
38,9
38,9
28 / 53
ONLINE-CATALOGUE
JA 157 115 L
JA 209 140 L
15,10 - 15,70
20,13 - 20,96
1150
1400
4,24
4,24
3
3
3-3-3
4-4-5
43,0
73,0
Material:
Helical rods: Aluminium alloy
Application:
Insulator ties JA...L are used to fix AAC, AAAC and ACSR conductors to post insulator type "Längsbund".
For post insulators of neck type they are -after clearifications with RIBE- suitable in special cases.
Mounting instruction:
See mounting instruction no. 7
Stand: 09. September 2008
Pfad: Helical formed fittings/ Insulator ties/ Insulator ties JA...L for post insulators type \"Längsbund\", for AAC, AAAC and ACSR conductors/
Gedruckt am: 16. Januar 2012
29 / 53
ONLINE-CATALOGUE
B432/2 Insulator ties JB...L for post insulators type "Längsbund", for copper and bronze conductors
RIBE-Order-No.
JB 052 076 L
JB 053 076 L
JB 055 076 L
JB 057 076 L
JB 060 076 L
JB 062 076 L
JB 065 080 L
JB 068 080 L
JB 071 080 L
JB 073 080 L
JB 075 085 L
JB 078 085 L
JB 082 085 L
JB 086 094 L
JB 089 094 L
JB 093 094 L
JB 096 094 L
JB 101 097 L
JB 104 097 L
JB 107 097 L
JB 112 102 L
JB 117 102 L
JB 122 109 L
JB 127 109 L
JB 132 109 L
Clamping range
D
mm
5,09 - 5,23
5,24 - 5,38
5,39 - 5,56
5,57 - 5,79
5,80 - 6,07
6,08 - 6,25
6,26 - 6,53
6,54 - 6,86
6,87 - 7,11
7,12 - 7,34
7,35 - 7,57
7,58 - 7,87
7,88 - 8,26
8,27 - 8,64
8,65 - 8,92
8,93 - 9,32
9,33 - 9,66
9,67 - 10,11
10,12 - 10,49
10,50 - 10,79
10,80 - 11,25
11,26 - 11,74
11,75 - 12,25
12,26 - 12,78
12,79 - 13,23
L
mm
760
760
760
760
760
760
800
800
800
800
850
850
850
940
940
940
940
970
970
970
1020
1020
1090
990
1090
S
mm
1,83
1,83
1,83
1,83
1,83
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,89
2,89
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
Helical rods
Number of subsets
Rods per subset
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3-3
Stand: 09. September 2008
Pfad: Helical formed fittings/ Insulator ties/ Insulator ties JB...L for post insulators type \"Längsbund\", for copper and bronze conductors/
Gedruckt am: 16. Januar 2012
Mass
kg/ 100 pieces
17,5
17,5
17,5
17,5
17,5
35,0
36,8
36,8
36,8
36,8
39,1
39,1
48,7
53,9
68,1
68,1
68,1
70,2
70,2
70,2
73,9
73,9
78,9
78,9
78,9
30 / 53
ONLINE-CATALOGUE
Material:
Helical rods: Copper alloy
Application:
Insulator ties JB...L are used to fix copper and copper alloy conductors (bronze) to post insulator type "Längsbund".
For post insulators of neck type they are -after clearifications with RIBE- suitable in special cases.
Mounting instruction:
See mounting instruction no. 7
Stand: 09. September 2008
Pfad: Helical formed fittings/ Insulator ties/ Insulator ties JB...L for post insulators type \"Längsbund\", for copper and bronze conductors/
Gedruckt am: 16. Januar 2012
31 / 53
ONLINE-CATALOGUE
B433/1 Side ties JW...H for neck type post insulators, for AAC, AAAC and ACSR conductors
RIBE-Order-No.
JW 050 035 H
JW 057 035 H
JW 070 042 H
JW 070 041 H
JW 080 033 H
JW 080 037 H
JW 080 038 H
JW 081 040 H
JW 081 041 H
JW 080 045 H
JW 083 050 H
JW 090 041 H
JW 090 044 H
JW 090 056 H
JW 090 053 H
JW 093 059 H
JW 096 060 H
JW 100 060 H
JW 103 049 H
JW 103 052 H
JW 103 047 H
JW 103 054 H
JW 103 060 H
JW 103 061 H
JW 116 055 H
JW 110 054 H
JW 116 061 H
JW 132 051 H
JW 132 054 H
JW 132 059 H
JW 132 065 H
JW 132 072 H
JW 132 083 H
JW 132 060 H
JW 132 062 H
JW 141 053 H
JW 149 061 H
JW 149 054 H
Clamping range
D1
Neck dia.
D2
L
Helical rods
S
No. of rods
mm
4,83 - 5,05
5,53 - 5,76
6,22 - 7,05
6,22 - 7,05
7,06 - 8,01
7,06 - 8,01
7,06 - 8,01
7,06 - 8,01
7,06 - 8,01
7,06 - 8,01
8,02 - 8,30
8,02 - 9,08
8,02 - 9,08
8,02 - 9,08
8,02 - 9,08
8,99 - 9,32
9,33 - 9,67
9,68 - 10,00
9,09 - 10,30
9,09 - 10,30
9,09 - 10,30
9,09 - 10,30
9,09 - 10,30
9,09 - 10,30
10,31 - 11,66
10,31 - 11,66
10,31 - 11,66
11,67 - 13,20
11,67 - 13,20
11,67 - 13,20
11,67 - 13,20
11,67 - 13,20
11,67 - 13,20
11,67 - 13,20
12,52 - 13,26
13,28 - 14,15
13,21 - 14,94
13,21 - 14,94
mm
70 - 74
70 - 74
70 - 74
85
43
50
70 - 74
80 - 81
85
93
50
72 - 75
80
85
88 - 90
43 - 45
80
73
70
82 - 85
93
100
116
120
73
78
85
72
75
80
85
100
116
140
43 - 45
73
62
75
mm
350
350
420
410
330
370
380
450
430
450
485
410
450
560
420
590
600
600
570
580
470
500
600
610
550
540
610
510
540
590
620
720
590
600
620
530
650
540
mm
2,05
2,05
2,30
2,30
2,30
2,30
2,59
2,59
2,59
2,30
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,9
2,9
2,9
2,9
2,9
2,9
2,9
2,9
2,9
2,9
2,9
2,9
2,9
2,9
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Stand: 08. Mai 2007
Pfad: Helical formed fittings/ Insulator ties/ Side ties JW...H for neck type post insulators, for AAC, AAAC and ACSR conductors/
Gedruckt am: 16. Januar 2012
Mass
kg/ 100 pieces
4,5
4,5
6,6
6,6
4,9
5,3
7,4
8,6
8,6
7,5
8,2
8,0
8,6
10,3
9,0
10,3
14,1
12,1
12,9
13,0
12,6
13,0
15,2
15,3
16,3
16,0
17,0
15,9
16,1
17,5
18,3
20,5
19,5
22,5
13,9
15,8
16,9
16,1
32 / 53
ONLINE-CATALOGUE
RIBE-Order-No.
JW 149 057 H
JW 149 062 H
JW 149 059 H
JW 149 075 H
JW 149 078 H
JW 160 054 H
JW 169 063 H
JW 169 075 H
JW 169 085 H
JW 169 077 H
JW 175 075 H
JW 191 076 H
JW 191 087 H
JW 218 066 H
JW 218 085 H
JW 246 083 H
Clamping range
D1
Neck dia.
D2
L
Helical rods
S
No. of rods
Mass
mm
13,21 - 14,94
13,21 - 14,94
13,21 - 14,94
13,21 - 14,94
13,21 - 14,94
15,12 - 16,02
14,95 - 16,95
14,95 - 16,95
14,95 - 16,95
14,95 - 16,95
15,50 - 17,50
16,96 - 19,18
16,96 - 19,18
19,19 - 21,80
19,19 - 21,80
21,81 - 24,68
mm
80
85
93
100
107
75
85
100
116
140
50
73
95
73
120
82
mm
570
570
590
700
780
540
670
700
770
700
600
760
870
660
850
830
mm
2,9
2,9
2,9
2,9
2,9
2,9
2,9
2,9
2,9
2,9
2,59
3,25
3,25
3,25
3,25
3,25
4
4
4
4
4
4
4
4
4
4
4
4
3
4
3
3
kg/ 100 pieces
16,9
17,0
18,8
20,7
23,3
16,3
19,7
20,5
22,7
22,3
11,5
18,6
21,4
17,9
24,1
21,3
Material:
Helical rods: Aluminium-clad steel
Application:
Side ties type JW...H are used to fix AAC, AAAC and ACSR conductors to the neck groove of medium voltage post insulators (vertical or horizontal position).
Mounting instruction:
See mounting instruction no. 38e
Stand: 08. Mai 2007
Pfad: Helical formed fittings/ Insulator ties/ Side ties JW...H for neck type post insulators, for AAC, AAAC and ACSR conductors/
Gedruckt am: 16. Januar 2012
33 / 53
ONLINE-CATALOGUE
B433/2 Side ties JH...H neck type post insulator, for AAC, AAAC, ACSR, copper and bronze conductors
RIBE-Order-No.
JH 070 042 H
JH 077 043 H
JH 090 043 H
JH 108 056 H
JH 116 051 H
JH 132 053 H
Clamping range
D1
Neck dia.
D2
L
Helical rods
S
No. of rods
Mass
mm
6,21 7,04
7,06 8,01
8,02 9,06
9,80 10,80
10,81 11,66
11,67 13,20
mm
73 78
73 78
73 78
73 78
73 78
73 78
mm
390
390
420
560
510
530
mm
2,31
2,31
2,31
2,56
2,56
2,56
3
3
3
4
4
4
kg/ 100 pieces
7,0
7,0
7,4
14,8
14,2
14,4
Material:
Helical rods: Stainless steel
Application:
Side ties type JW...H are used to fix AAC, AAAC and ACSR conductors to the neck groove of medium voltage post insulators (vertical or horizontal position).
Mounting instruction:
See mounting instruction no. 38e
Stand: 22. Juni 2006
Pfad: Helical formed fittings/ Insulator ties/ Side ties JH...H neck type post insulator, for AAC, AAAC, ACSR, copper and bronze conductors/
Gedruckt am: 16. Januar 2012
34 / 53
ONLINE-CATALOGUE
B433/3 Side ties JV...H for neck type post insulators, for copper and bronze conductors
RIBE-Order-No.
JV 080 052 H
JV 090 058 H
JV 090 065 H
JV 093 052 H
JV 116 060 H
JV 111 061 H
JV 132 054 H
JV 123 060 H
Clamping range
D1
Neck dia.
D2
L
Helical rods
S
No. of rods
Mass
mm
7,06 - 8,01
8,02 - 9,08
8,02 - 9,08
8,99 - 9,32
10,31 - 11,66
10,46 - 11,10
12,50 - 13,27
12,50 - 13,27
mm
72
78
92
72
50
35
75
80
mm
520
550
560
520
550
800
540
600
mm
2,59
2,59
2,59
2,59
2,59
2,59
2,89
2,59
3
4
3
4
4
3
4
4
kg/ 100 pieces
11,8
15,6
13,2
14,4
14,7
13,5
19,3
21,1
Material:
Helical rods: Copper-clad steel
Application:
Side ties type JW...H are used to fix AAC, AAAC and ACSR conductors to the neck groove of medium voltage post insulators (vertical or horizontal position).
Mounting instruction:
See mounting instruction no. 38e
Stand: 22. Juni 2006
Pfad: Helical formed fittings/ Insulator ties/ Side ties JV...H for neck type post insulators, for copper and bronze conductors/
Gedruckt am: 16. Januar 2012
35 / 53
ONLINE-CATALOGUE
B439/1 Insulator ties JA...Ls for post insulators type StV, for AAC, AAAC and ACSR conductors
RIBE-Order-No.
JA 080 088 Ls
JA 090 089 Ls
JA 100 090 Ls
JA 110 090 Ls
JA 120 100 Ls
JA 130 105 Ls
JA 140 106 Ls
JA 150 125 Ls
JA 160 130 Ls
JA 170 135 Ls
JA 180 140 Ls
JA 193 145 Ls
JA 200 150 Ls
JA 210 150 Ls
Clamping range
D
mm
7,1 - 8,0
8,1 - 9,0
9,1 - 10,0
10,1 - 11,0
11,1 - 12,0
12,1 - 13,0
13,1 - 14,0
14,1 - 15,0
15,1 - 16,0
16,1 - 17,0
17,1 - 18,0
18,1 - 19,0
19,1 - 20,0
20,1 - 21,0
L
mm
880
890
900
900
1000
1050
1060
1250
1300
1350
1400
1450
1500
1500
S
mm
2,59
3,07
3,07
3,07
3,07
3,70
3,70
3,70
3,70
3,70
3,70
3,70
3,70
3,70
Helical rods
Number of subsets
Rods per subset
Mass
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4-3-3
4-3-3
4-3-3
4-3-3
4-3-3
5-3-3
5-3-3
5-3-3
5-3-3
5-3-3
6-3-3
6-3-3
6-3-3
6-3-3
kg/ 100 pieces
13,1
18,7
19,2
19,2
21,5
36,0
37,0
43,6
45,4
47,1
54,7
56,7
59,0
59,5
Material:
Helical rods: Aluminium alloy
Application:
The ties type JA...Ls are suitable to fix AAC, AAAC and ACSR conductors to post insulators type StV 10, StV 20 and StV 30 according to TGL standard 200-6040.
They can be used for horizontal line angles of 180° ± 5°.
Stand: 09. September 2008
Pfad: Helical formed fittings/ Insulator ties/ Insulator ties JA...Ls for post insulators type StV, for AAC, AAAC and ACSR conductors/
Gedruckt am: 16. Januar 2012
36 / 53
ONLINE-CATALOGUE
B439/2 Insulator ties VA...s/JA...Ls to reinforce AAC, AAAC and ACSR conductors at post insulators StV
RIBE-Order-No.
Clamping range
D
mm
VA 080 130 s
JA 131 110 Ls
VA 090 140 s
JA 151 119 Ls
VA 100 150 s
JA 161 128 Ls
VA 110 152 s
JA 171 132 Ls
VA 120 165 s
JA 181 145 Ls
VA 130 180 s
JA 204 160 Ls
VA 140 185 s
JA 214 165 Ls
VA 150 195 s
JA 224 175 Ls
VA 160 225 s
JA 234 205 Ls
VA 180 225 s
JA 254 205 Ls
7,1 bis 8,0
8,1 bis 9,0
9,1 bis 10,0
10,1 bis 11,0
11,1 bis 12,0
12,1 bis 13,0
13,1 bis 14,0
14,1 bis 15,0
15,1 bis 16,0
17,1 bis 18,0
Helical rods
Mass
L1
L2
S1
S2
mm
1300
mm
mm
2,59
mm
1100
1400
2,59
3,07
1190
1500
3,07
3,07
1280
1520
3,07
3,07
1320
1520
3,07
3,07
1450
1800
3,07
3,70
1600
1850
3,70
3,70
1650
1950
3,70
3,70
1750
2250
3,70
3,70
2050
2250
3,70
3,70
2050
4,24
Stand: 09. September 2008
Pfad: Helical formed fittings/ Insulator ties/ Insulator ties VA...s/JA...Ls to reinforce AAC, AAAC and ACSR conductors at post insulators StV/
Gedruckt am: 16. Januar 2012
Number of subsets Rods per subset
kg/ 100 pieces
2
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
4
2
5-5
3-3
3-3-3
3-3
4-3-3
3-3
4-4-4
3-3
4-4-4
3-3
3-4-4
3-3
4-4-4
3-3
5-4-4
3-3
5-5-4
3-3
4-4-4-3
3-3
30,0
42,5
52,3
56,7
58,5
97,6
106,3
113,7
139,3
160,5
37 / 53
ONLINE-CATALOGUE
Material:
Helical rods: Aluminium alloy
Application:
The combination of VA...s- and JA...Ls-spirals is suitable for reinforcing damaged AAC, AAAC and ACSR conductors at post insulators type StV 10, StV 20 and StV 30 of
TGL-standard 200-6040.
The allowed grade of damage is up to breakage of all al-wires of conductor.
Stand: 09. September 2008
Pfad: Helical formed fittings/ Insulator ties/ Insulator ties VA...s/JA...Ls to reinforce AAC, AAAC and ACSR conductors at post insulators StV/
Gedruckt am: 16. Januar 2012
38 / 53
ONLINE-CATALOGUE
B441/1 Patch rods (RA) for AAC, AAAC, ACSR and AACSR conductors
1 ..... Colored center mark
RIBE-Order-No.
RA 040 023
RA 042 023
RA 044 023
RA 046 023
RA 049 025
RA 051 030
RA 053 025
RA 055 030
RA 057 028
RA 060 028
RA 062 030
RA 065 030
RA 068 033
RA 071 033
RA 073 033
RA 075 036
RA 078 036
RA 082 036
RA 086 038
RA 089 038
RA 093 041
RA 096 043
RA 101 046
RA 104 046
RA 107 046
RA 112 051
RA 117 051
RA 117 150 s
RA 122 053
RA 127 056
RA 132 058
RA 138 061
RA 144 064
RA 150 064
RA 157 066
RA 163 069
RA 170 074
RA 177 076
RA 185 081
RA 193 081
RA 201 089
Clamping range
D
mm
3,92 - 4,09
4,10 - 4,27
4,28 - 4,47
4,48 - 4,67
4,68 - 4,90
4,91 - 5,13
5,14 - 5,38
5,39 - 5,56
5,57 - 5,79
5,80 - 6,07
6,08 - 6,25
6,26 - 6,53
6,54 - 6,86
6,87 - 7,11
7,12 - 7,34
7,35 - 7,57
7,58 - 7,87
7,88 - 8,26
8,27 - 8,64
8,65 - 8,92
8,93 - 9,32
9,33 - 9,66
9,67 - 10,11
10,12 - 10,49
10,50 - 10,79
10,80 - 11,25
11,26 - 11,74
11,26 - 11,74
11,75 - 12,25
12,26 - 12,78
12,79 - 13,23
13,24 - 13,82
13,83 - 14,40
14,41 - 15,09
15,10 - 15,70
15,71 - 16,36
16,37 - 17,04
17,05 - 17,78
17,79 - 18,52
18,53 - 19,30
19,31 - 20,12
l
mm
230
230
230
230
250
300
250
300
280
280
300
300
330
330
330
360
360
360
380
380
410
430
460
460
460
510
510
1500
530
560
580
610
640
640
660
690
740
760
810
810
890
Stand: 31. Mai 2010
Pfad: Helical formed fittings/ Patch rods/ Patch rods (RA) for AAC, AAAC, ACSR and AACSR conductors/
Gedruckt am: 16. Januar 2012
S
mm
2,18
2,18
2,18
2,18
2,18
2,18
2,18
2,18
2,18
2,18
2,38
2,38
2,38
2,38
2,38
2,38
2,59
2,59
2,59
2,59
2,59
3,07
3,07
3,07
3,07
3,45
3,45
3,45
3,45
3,71
3,71
4,24
4,24
4,62
4,62
4,62
5,18
5,18
6,35
6,35
6,35
Helical rods
No. of rods
7
7
8
8
8
8
9
9
9
10
9
9
10
10
10
11
10
10
11
11
12
11
11
11
12
11
11
11
12
11
12
11
11
11
11
12
11
11
10
10
11
Mass
Rods per subset
3-4
3-4
4-4
4-4
4-4
4-4
3-3-3
3-3-3
3-3-3
5-5
3-3-3
3-3-3
5-5
5-5
5-5
3-4-4
5-5
5-5
3-4-4
3-4-4
4-4-4
3-4-4
3-4-4
3-4-4
4-4-4
3-4-4
3-4-4
3-4-4
4-4-4
3-4-4
4-4-4
3-4-4
3-4-4
3-4-4
3-4-4
4-4-4
3-4-4
3-4-4
3-3-4
3-3-4
3-4-4
kg/ 100 pieces
1,8
1,8
2,0
2,0
2,2
2,2
2,5
2,5
2,8
3,1
3,6
3,6
4,4
4,4
4,4
6,2
5,6
6,0
6,5
6,5
7,7
10,4
11,1
11,1
12,1
15,5
15,5
45,0
17,6
19,7
22,2
27,9
29,3
34,8
35,9
40,9
50,5
51,9
73,0
83,1
91,3
39 / 53
ONLINE-CATALOGUE
RIBE-Order-No.
Clamping range
Helical rods
D
l
S
No. of rods
mm
mm
mm
RA 209 091
20,13 - 20,96
910
6,35
11
RA 215 094
20,97 - 21,59
940
6,35
11
RA 225 099
21,60 - 22,50
990
6,35
12
RA 236 099
22,51 - 23,60
990
7,87
10
RA 245 104
23,61 - 24,59
1040
7,87
11
RA 254 114
24,50 - 25,42
1140
7,87
11
RA 266 114
25,43 - 26,67
1140
7,87
11
RA 277 119
26,68 - 27,71
1190
7,87
12
RA 288 122
27,72 - 28,86
1220
7,87
12
RA 300 127
28,87 - 30,05
1270
7,87
13
RA 312 137
30,06 - 31,29
1370
9,27
11
RA 329 142
31,30 - 32,99
1420
9,27
12
RA 343 147
33,00 - 34,36
1470
9,27
12
RA 358 152
34,37 -35,80
1520
9,27
13
RA 372 165
35,81 - 37,26
1650
9,27
13
RA 388 168 s
37,27 - 38,80
1680
9,27
13
RA 404 173 s
38,81 - 40,40
1730
9,27
14
RA 421 178 s
40,41 - 42,10
1780
9,27
14
RA 438 200 s
42,11 - 43,80
2000
9,27
15
RA 500 212
48,64 - 50,00
2120
9,27
17
RA 517 215
50,10 - 51,70
2150
9,27
17
RA 562 220
54,48 - 56,28
2200
9,27
18
*) Armor splices consist of single rods with antifriction paste. The paste has to be applicated to the surface of the conductor at installation location.
Mass
Rods per subset
3-4-4
3-4-4
3-3-3-3
*)
kg/ 100 pieces
93,3
96,4
110,7
141,7
163,8
179,6
179,6
204,4
209,6
236,4
299,5
338,5
458,1
473,6
514,2
571,2
588,0
605,2
679,0
698,0
709,0
741,0
Material:
Helical rods: Aluminium alloy
Application:
Patch rods are used in the free span to repair conductor damages up to 25% of the outer layer of AAC, AAAC, ACSR and AACSR conductors. They are capable to restore
the original mechanical and electrical properties of the conductor.
For damages of more then 25% of outer layer line splices type VA and up to total breakage of conductor line splices type VAG can be used. If steel core is undamaged
outer splice (al. alloy) of VAG is sufficient, use of filler spirals may be necessary (page B421/1).
For damages at suspension clamps use of armor rods SA (page B451/1) or of armor splices SVA (page B454/2) is recommended.
Mounting instruction:
See mounting instruction no. 39
Stand: 31. Mai 2010
Pfad: Helical formed fittings/ Patch rods/ Patch rods (RA) for AAC, AAAC, ACSR and AACSR conductors/
Gedruckt am: 16. Januar 2012
40 / 53
ONLINE-CATALOGUE
B442/1 Patch rods (RG) for stranded steel conductors, h.d.g.
1 ..... Colored center mark
RIBE-Orde-No.
RG 026 015
RG 027 015
RG 029 018
RG 030 018
RG 032 018
RG 033 018
RG 035 018
RG 036 020
RG 038 020
RG 040 020
RG 041 020
RG 044 023
RG 046 023
RG 048 024
RG 050 024
RG 052 025
RG 054 026
RG 056 028
RG 059 029
RG 062 032
RG 064 032
RG 067 032
RG 070 035
RG 073 035
RG 076 036
RG 079 036
RG 082 036
RG 085 037
RG 089 038
RG 093 039
RG 096 040
RG 100 042
RG 104 044
RG 108 046
RG 111 048
RG 114 050
RG 117 051
RG 120 052
RG 125 054
RG 130 056
RG 135 058
RG 139 058
Clamping range
D
mm
2,54 - 2,64
2,65 - 2,77
2,78 - 2,90
2,91 - 3,05
3,06 - 3,20
3,21 - 3,35
3,36 - 3,50
3,51 - 3,66
3,67 - 3,84
3,85 - 4,01
4,02 - 4,19
4,20 - 4,40
4,41 - 4,60
4,61 - 4,80
4,81 - 5,00
5,01 - 5,23
5,24 - 5,46
5,47 - 5,69
5,70 - 5,94
5,95 - 6,20
6,21 - 6,45
6,46 - 6,73
6,74 - 7,01
7,02 - 7,32
7,33 - 7,62
7,63 - 7,95
7,96 - 8,28
8,29 - 8,58
8,59 - 8,95
8,96 - 9,30
9,31 - 9,68
9,69 - 10,06
10,07 - 10,45
10,46 - 10,80
10,81 - 11,10
11,11 - 11,45
11,46 - 11,75
11,76 - 12,05
12,06 - 12,55
12,56 - 13,05
13,06 - 13,50
13,51 - 13,94
L
mm
150
150
180
180
180
180
180
200
200
200
200
230
230
240
240
250
260
280
290
320
320
320
350
350
360
360
360
370
380
390
400
420
440
460
480
500
510
520
540
560
580
580
Stand: 11. Mai 2007
Pfad: Helical formed fittings/ Patch rods/ Patch rods (RG) for stranded steel conductors, h.d.g./
Gedruckt am: 16. Januar 2012
S
mm
1,30
1,30
1,30
1,30
1,30
1,55
1,55
1,55
1,55
1,78
1,78
1,78
2,18
2,18
2,18
1,78
1,78
1,78
1,78
2,18
2,18
2,18
2,18
2,54
2,54
2,54
2,54
3,02
3,02
2,54
2,54
3,02
3,02
3,02
3,02
3,02
3,51
3,51
3,51
3,51
4,04
4,04
Helical rods
No. of rods
6
8
8
8
8
8
8
8
8
8
8
8
8
8
8
10
10
10
11
10
10
10
11
10
10
10
11
10
10
12
12
11
11
12
12
12
11
11
12
12
11
11
Mass
Rods per subset
3-3
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
5-5
5-5
5-5
3-4-4
5-5
5-5
5-5
3-4-4
5-5
5-5
5-5
3-4-4
3-3-4
3-3-4
4-4-4
4-4-4
3-4-4
3-4-4
4-4-4
4-4-4
4-4-4
3-4-4
3-4-4
4-4-4
4-4-4
3-4-4
3-4-4
kg/ 100 pieces
1,1
1,5
1,8
1,8
1,8
2,5
2,5
2,8
2,8
3,6
3,6
4,1
6,2
6,5
6,5
5,6
5,8
6,3
7,2
10,9
10,9
10,9
13,1
15,9
16,3
16,3
17,9
23,5
24,2
21,2
21,7
29,3
30,7
35,0
36,6
38,0
47,8
48,8
55,2
57,3
72,5
72,5
41 / 53
ONLINE-CATALOGUE
RIBE-Orde-No.
RG 145 060
RG 151 062
RG 157 065
RG 163 067
RG 168 068
RG 178 072
RG 190 078
Clamping range
D
mm
13,95 - 14,53
14,54 - 15,15
15,16 - 15,75
15,76 - 16,36
16,37 - 16,80
17,31 - 17,85
18,43 - 19,05
L
mm
600
620
650
670
680
720
780
S
mm
4,04
4,04
4,37
4,37
4,37
4,37
4,37
Helical rods
No. of rods
12
12
12
12
12
13
13
Mass
Rods per subset
3-3-3-3
3-3-3-3
3-3-3-3
3-3-3-3
3-3-3-3
3-3-3-4
3-3-3-4
kg/ 100 pieces
81,7
84,5
103,4
106,6
108,2
118,0
128,0
Material:
Helical rods: Steel, h.d.g.
Application:
Patch rods are used in the free span to repair damages up to 25% of the outer layer of steel conductors hot dip galvanized. They are capable to restore the original
mechanical and electrical properties of the conductor.
For damages of more than 25% of the outer layer line splices VG (see page B422/3) can be used.
For damages at suspension clamps use of armor rods SG (page B454/1) to recommended.
Mounting instruction:
See mountimng instruction no. 39
Stand: 11. Mai 2007
Pfad: Helical formed fittings/ Patch rods/ Patch rods (RG) for stranded steel conductors, h.d.g./
Gedruckt am: 16. Januar 2012
42 / 53
ONLINE-CATALOGUE
B443/1 Patch rods (RK) for copper and copper alloy conductors
1 ..... Colored center mark
RIBE-Order-No.
RK 041 020
RK 042 023
RK 045 023
RK 050 023
RK 052 025
RK 055 025
RK 057 025
RK 061 028
RK 062 028
RK 064 030
RK 066 030
RK 068 030
RK 069 033
RK 071 033
RK 073 033
RK 075 033
RK 077 036
RK 079 036
RK 081 036
RK 084 038
RK 086 038
RK 088 041
RK 091 041
RK 093 041
RK 096 043
RK 099 043
RK 102 046
RK 105 046
RK 107 048
RK 109 048
RK 111 050
RK 114 050
RK 117 053
RK 121 053
RK 124 053
RK 126 056
RK 130 058
RK 131 058
RK 135 058
RK 137 058
RK 139 058
RK 142 061
Clamping range
D
mm
4,02 - 4,19
4,20 - 4,29
4,40 - 4,55
4,94 - 5,08
5,09 - 5,23
5,39 - 5,54
5,55 - 5,74
5,98 - 6,13
6,14 - 6,27
6,28 - 6,47
6,48 - 6,65
6,66 - 6,81
6,82 - 6,98
6,99 - 7,19
7,20 - 7,37
7,38 - 7,57
7,58 - 7,75
7,76 - 7,91
7,92 - 8,15
8,16 - 8,43
8,44 - 8,66
8,67 - 8,87
8,88 - 9,14
9,15 - 9,32
9,33 - 9,60
9,61 - 9,93
9,94 - 10,26
10,27 - 10,54
10,55 - 10,71
10,72 - 10,97
10,98 - 11,18
11,19 - 11,48
11,49 - 11,76
11,77 - 12,14
12,15 - 12,44
12,45 - 12,62
12,63 - 13,00
13,01 - 13,18
13,19 - 13,51
13,52 - 13,71
13,72 - 13,97
13,98 - 14,27
L
mm
200
230
230
230
250
250
250
280
280
300
300
300
330
330
330
330
360
360
360
380
380
410
410
410
430
430
460
460
480
480
500
500
530
530
530
560
580
580
580
580
580
610
Stand: 11. Mai 2007
Pfad: Helical formed fittings/ Patch rods/ Patch rods (RK) for copper and copper alloy conductors/
Gedruckt am: 16. Januar 2012
S
mm
1,83
1,83
1,83
1,83
1,83
1,83
2,06
2,06
2,06
2,06
2,31
2,31
2,31
2,31
2,31
2,31
2,31
2,31
2,31
2,59
2,59
2,59
2,59
2,89
2,89
2,89
2,89
2,59
2,89
3,66
3,66
3,66
3,66
3,66
3,66
3,66
3,66
3,66
3,66
3,66
3,66
3,66
Helical rods
No. of rods
8
8
9
9
10
10
10
10
10
11
10
10
10
10
11
11
11
11
11
11
11
11
11
11
11
11
12
13
12
10
10
10
11
11
11
11
12
12
12
12
12
13
Mass
Rods per subset
4-4
4-4
3-3-3
3-3-3
5-5
5-5
5-5
5-5
5-5
3-4-4
5-5
5-5
5-5
5-5
3-4-4
3-4-4
3-4-4
3-4-4
3-4-4
3-4-4
3-4-4
3-4-4
3-4-4
3-4-4
3-4-4
3-4-4
4-4-4
4-4-5
4-4-4
3-3-4
3-3-4
3-3-4
3-4-4
3-4-4
3-4-4
3-4-4
4-4-4
4-4-4
4-4-4
4-4-4
4-4-4
4-4-5
kg/ 100 pieces
4,0
4,6
5,2
5,2
6,3
6,3
8,1
9,1
9,1
10,7
12,2
12,2
13,5
13,5
14,8
14,8
16,2
16,2
16,2
21,4
21,4
23,1
23,1
28,8
30,2
30,2
35,2
30,0
36,8
49,1
51,1
51,1
59,6
59,6
59,6
62,9
71,1
71,1
71,1
71,1
71,1
81,0
43 / 53
ONLINE-CATALOGUE
RIBE-Order-No.
Clamping range
Helical rods
D
L
S
No. of rods
mm
mm
mm
RK 146 061
14,28 - 14,63
610
3,66
13
RK 150 063
14,64 - 15,01
630
3,66
13
RK 153 066
15,02 - 15,37
660
4,11
12
RK 158 066
15,38 - 15,85
660
4,11
12
RK 162 068
15,86 - 16,23
680
4,11
13
RK 166 068
16,24 - 16,64
680
4,11
13
RK 170 071
16,65 - 17,07
710
4,11
13
RK 174 073
17,08 - 17,40
730
4,62
12
RK 177 076
17,41 - 17,78
760
4,62
12
RK 181 076
17,79 - 18,13
760
4,62
13
RK 185 079
18,14 - 18,54
790
4,62
13
RK 189 079
18,55 - 18,92
790
4,62
13
RK 193 081
18,93 - 19,30
810
4,62
13
RK 196 084
19,31 - 19,68
840
4,62
14
RK 200 086
19,69 - 20,06
860
5,18
13
RK 205 086
20,07 - 20,52
860
5,18
13
RK 209 086
20,53 - 20,95
860
5,18
13
RK 213 090
20,96 - 21,38
900
5,18
13
RK 218 094
21,39 - 21,84
940
5,82
12
RK 221 094
21,85 - 22,10
940
5,82
12
RK 223 096
22,11 - 22,35
960
5,82
13
RK 227 099
22,36 - 22,73
990
5,82
13
RK 231 099
22,74 - 23,16
990
5,82
13
RK 236 101
23,17 - 23,62
1010
5,82
13
RK 240 101
23,63 - 24,08
1010
5,82
13
RK 245 104
24,09 - 24,58
1040
6,55
12
RK 251 104
24,59 - 25,14
1040
6,55
12
RK 256 109
25,15 - 26,65
1090
6,55
13
RK 262 112
25,66 - 26,21
1120
6,55
13
RK 267 114
26,22 - 26,79
1140
7,34
12
RK 273 117
26,80 - 27,33
1170
7,34
12
RK 279 117
27,34 - 27,94
1170
7,34
12
RK 283 122
27,95 - 28,35
1220
7,34
13
RK 287 122
28,36 - 28,75
1220
7,34
13
RK 293 124
28,76 - 29,31
1240
7,34
13
RK 298 124
29,32 - 29,84
1240
7,34
13
RK 304 129
29,85 - 30,48
1290
8,25
12
*) Armor splices consist of single rods with antifriction paste. The paste has to be applicated to the surface of the conductor at installation location.
Mass
Rods per subset
4-4-5
4-4-5
4-4-4
4-4-4
4-4-5
4-4-5
4-4-5
4-4-4
4-4-4
4-4-5
4-4-5
4-4-5
4-4-5
4-5-5
3-3-3-4
3-3-3-4
3-3-3-4
3-3-3-4
3-3-3-3
3-3-3-3
3-3-3-4
3-3-3-4
3-3-3-4
3-3-3-4
3-3-3-4
3-3-3-3
3-3-3-3
3-3-3-4
3-3-3-4
*)
kg/ 100 pieces
81,0
83,6
102,0
102,0
113,9
113,9
118,8
142,6
148,5
160,8
167,2
167,2
171,4
191,4
228,7
228,7
228,7
239,2
291,2
291,2
322,2
332,4
332,4
338,8
338,8
408,0
408,0
463,4
475,9
561,5
576,4
576,4
650,8
650,8
661,6
661,6
669,2
Material:
Helical rods: Copper alloy
Application:
Patch rods are used in the free span to repair damages of the outer layer up to 25%. They are capable to restore the original electrical and mechanical properties of the
conductor. For damages of more than 25% of the outer layer line splices VK (see page B422/2) can be used.
For damanges at suspensions clamps use of armor rods SB (page B453/1) is recommended.
Mounting instruction:
See mounting instruction no. 39
Stand: 11. Mai 2007
Pfad: Helical formed fittings/ Patch rods/ Patch rods (RK) for copper and copper alloy conductors/
Gedruckt am: 16. Januar 2012
44 / 53
ONLINE-CATALOGUE
B451/1 Armor rods (SA) for AAC, AAAC, ACSR and AACSR conductors
1 ..... Colored center mark
RIBE-Order-No.
SA 051 102
SA 052 102
SA 053 102
SA 055 102
SA 057 102
SA 058 102
SA 059 102
SA 061 102
SA 063 102
SA 065 102
SA 067 102
SA 068 102
SA 069 102
SA 071 102
SA 073 102
SA 075 102
SA 077 107
SA 080 107
SA 082 112
SA 084 112
SA 086 117
SA 088 122
SA 090 122
SA 093 122
SA 098 127
SA 105 132
SA 111 137
SA 119 137
SA 126 142
SA 131 142
SA 136 142
SA 143 152
SA 149 163
SA 158 163
SA 166 163
SA 175 173
SA 179 173
SA 186 183
SA 195 183
SA 203 139
SA 212 193
SA 224 198
Clamping range
D1
Outer diameter
D2
L
Helical rods
Rod dia.
No. of rods
4,99 - 5,10
5,11 - 5,23
5,24 - 5,38
5,39 - 5,54
5,55 - 5,76
5,77 - 5,82
5,83 - 5,97
5,98 - 6,15
6,16 - 6,32
6,33 - 6,53
6,54 - 6,70
6,71 - 6,86
6,87 - 6,98
6,99 - 7,16
7,17 - 7,37
7,38 - 7,57
7,58 - 7,75
7,76 - 8,00
8,01 - 8,25
8,26 - 8,43
8,44 - 8,64
8,65 - 8,81
8,82 - 9,07
9,08 - 9,35
9,36 - 9,86
9,87 - 10,54
10,55 - 11,18
11,19 - 11,94
11,95 - 12,65
12,66 - 13,16
13,17 - 13,64
13,65 - 14,35
14,36 - 14,91
14,92 - 15,88
15,89 - 16,66
16,67 - 17,50
17,51 - 17,93
17,94 - 18,64
18,65 - 19,53
19,51 - 20,32
20,33 - 21,21
21,22 - 22,45
11,2
11,4
11,5
11,7
11,9
12,0
12,1
13,6
13,7
14,0
14,1
14,3
14,4
14,6
14,8
15,0
15,2
15,4
15,7
15,9
16,1
16,2
16,5
16,8
18,3
19,0
19,7
20,4
21,1
21,6
22,1
23,6
24,3
25,1
25,9
26,7
28,2
29,0
29,9
33,0
33,9
35,2
mm
1020
1020
1020
1020
1020
1020
1020
1020
1020
1020
1020
1020
1020
1020
1020
1020
1070
1070
1120
1120
1170
1220
1220
1220
1270
1320
1370
1370
1420
1420
1420
1520
1630
1630
1630
1730
1730
1830
1830
1930
1930
1980
mm
3,07
3,07
3,07
3,07
3,07
3,07
3,07
3,71
3,71
3,71
3,71
3,71
3,71
3,71
3,71
3,71
3,71
3,71
3,71
3,71
3,71
3,71
3,71
3,71
4,24
4,24
4,24
4,24
4,24
4,24
4,24
4,62
4,62
4,62
4,62
4,62
5,18
5,18
5,18
6,35
6,35
6,35
7
7
7
7
8
8
8
7
7
7
7
7
8
8
8
8
8
8
8
9
9
9
9
9
9
9
9
9
10
11
11
11
11
11
12
12
12
12
13
11
11
12
Stand: 11. Mai 2007
Pfad: Helical formed fittings/Armor rods/ Armor rods (SA) for AAC, AAAC, ACSR and AACSR conductors/
Gedruckt am: 16. Januar 2012
Weight
kg/ 100 pieces
15,6
15,6
15,6
15,6
15,6
17,8
17,8
22,8
22,8
22,8
22,8
22,8
26,0
26,0
26,0
26,0
27,2
27,2
28,5
32,1
33,5
35,0
35,0
35,0
47,5
49,4
56,9
56,9
59,0
64,9
64,9
82,6
88,6
88,6
96,6
102,6
128,8
136,2
147,6
197,9
197,9
221,4
45 / 53
ONLINE-CATALOGUE
RIBE-Order-No.
SA 235 203
SA 249 213
SA 262 234
SA 276 244
SA 289 254
SA 304 254
SA 321 254
SA 337 254
SA 354 254
SA 372 254
SA 388 254
SA 401 254
SA 517 274
Clamping range
D1
Outer diameter
D2
L
Helical rods
Rod dia.
No. of rods
Weight
22,46 - 23,57
23,58 - 24,97
24,98 - 26,26
26,27 - 27,69
27,70 - 28,96
28,97 - 30,43
30,44 - 32,13
32,14 - 33,78
33,79 - 35,46
35,47 - 37,21
37,22 - 38,86
38,87 - 40,13
49,70 - 51,70
36,3
37,7
42,0
43,4
44,7
46,2
50,7
52,3
54,0
55,8
57,4
58,7
70,2
mm
2030
2130
2340
2440
2540
2540
2540
2540
2540
2540
2540
2540
2740
mm
6,35
6,35
7,87
7,87
7,87
7,87
9,27
9,27
9,27
9,27
9,27
9,27
9,27
12
13
11
12
12
13
12
12
13
13
13
14
17
kg/ 100 pieces
227,1
258,1
368,5
419,1
436,3
472,6
605,4
605,4
655,9
642,4
641,6
691,5
901,0
Material:
Helical rods: Aluminium alloy
Application:
Use of armor rods SA reduces bending stress at clamping points (f.e. suspension clamps) at AAC, AAAC, ACSR and AACSR conductors. They have no damping
properties.
Armor rods can be used as patch rods up to damages of 25% of the outer layer at suspension points. By this they protect the conductor against damages by arcing foot
points, too.
Mounting instruction:
See instruction-no. 48
Stand: 11. Mai 2007
Pfad: Helical formed fittings/Armor rods/ Armor rods (SA) for AAC, AAAC, ACSR and AACSR conductors/
Gedruckt am: 16. Januar 2012
46 / 53
ONLINE-CATALOGUE
B453/1 Armor rods (SB) for copper and bronze conductors
1 ..... Colored center mark
RIBE-Order-No.
SB 041 102
SB 042 102
SB 043 102
SB 045 102
SB 046 102
SB 047 102
SB 049 102
SB 050 102
SB 052 102
SB 053 102
SB 055 102
SB 057 102
SB 059 102
SB 061 102
SB 062 102
SB 064 102
SB 066 107
SB 068 107
SB 069 107
SB 071 107
SB 073 107
SB 075 107
SB 077 117
SB 079 117
SB 081 117
SB 084 117
SB 086 122
SB 088 127
SB 091 127
SB 093 132
SB 096 132
SB 098 137
SB 102 142
SB 107 142
SB 111 142
SB 116 142
SB 123 142
SB 130 142
SB 135 147
SB 139 152
SB 146 152
SB 152 152
Clamping range
D1
Outer diameter
D2
L
mm
4,02 - 4,19
4,20 - 4,29
4,30 - 4,39
4,40 - 4,55
4,56 - 4,67
4,68 - 4,78
4,79 - 4,93
4,94 - 5,08
5,09 - 5,23
5,24 - 5,38
5,39 - 5,54
5,55 - 5,74
5,75 - 5,97
5,98 - 6,13
6,14 - 6,27
6,28 - 6,47
6,48 - 6,65
6,66 - 6,81
6,82 - 6,98
6,99 - 7,19
7,20 - 7,37
7,38 - 7,57
7,58 - 7,75
7,76 - 7,91
7,92 - 8,15
8,16 - 8,43
8,44 - 8,66
8,67 - 8,87
8,88 - 9,14
9,15 - 9,32
9,33 - 9,60
9,61 - 9,85
9,86 - 10,29
10,30 - 10,71
10,72 - 11,10
11,11 - 11,63
11,64 - 12,35
12,36 - 13,00
13,01 - 13,51
13,52 - 13,97
13,98 - 14,60
14,61 - 15,27
mm
9,4
9,5
9,6
9,7
9,9
10,0
10,1
10,3
10,4
10,6
10,7
10,9
11,2
11,3
11,5
11,7
11,8
12,0
12,2
12,4
12,6
13,4
13,5
13,7
14,7
14,9
15,2
15,4
15,6
15,8
16,1
16,4
17,6
18,0
19,3
19,9
20,6
21,2
21,7
22,2
22,8
23,5
mm
1020
1020
1020
1020
1020
1020
1020
1020
1020
1020
1020
1020
1020
1020
1020
1020
1070
1070
1070
1070
1070
1070
1170
1170
1170
1170
1220
1270
1270
1320
1320
1370
1420
1420
1420
1420
1420
1420
1470
1520
1520
1520
Stand: 11. Mai 2007
Pfad: Helical formed fittings/Armor rods/ Armor rods (SB) for copper and bronze conductors/
Gedruckt am: 16. Januar 2012
Helical rods
Rod dia.
mm
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,59
2,89
2,89
2,89
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,25
3,66
3,66
4,11
4,11
4,11
4,11
4,11
4,11
4,11
4,11
Weight
No. of rods
7
7
7
7
7
7
7
7
8
8
8
8
9
9
9
9
9
10
10
10
10
10
9
10
9
9
10
10
10
10
10
11
10
10
10
10
10
11
11
12
12
12
kg/ 100 pieces
36,5
36,5
36,5
36,5
36,5
36,5
36,5
36,5
41,8
41,8
41,8
41,8
47,0
47,0
47,0
47,0
49,2
54,7
54,7
54,7
54,7
68,1
74,5
74,5
84,7
84,7
98,2
102,2
102,2
106,2
106,2
121,3
144,9
144,9
182,7
182,7
182,7
201,0
227,0
234,7
234,7
234,7
47 / 53
ONLINE-CATALOGUE
RIBE-Order-No.
SB 160 152
SB 167 152
SB 176 162
SB 184 162
SB 191 168
SB 199 168
SB 207 173
SB 214 173
SB 222 178
SB 231 178
Clamping range
D1
Outer diameter
D2
L
mm
15,28 - 16,00
16,01 - 16,77
16,78 - 17,62
17,63 - 18,49
18,50 - 19,18
19,19 - 19,94
19,95 - 20,70
20,71 - 21,46
21,47 - 22,25
22,26 - 23,11
mm
25,2
26,0
26,8
27,7
28,4
29,2
29,9
31,5
32,6
33,5
mm
1520
1520
1620
1620
1680
1680
1730
1730
1780
1780
Helical rods
Rod dia.
mm
4,62
4,62
4,62
4,62
4,62
4,62
4,62
5,18
5,18
5,18
Weight
No. of rods
12
12
13
13
14
14
15
13
14
15
kg/ 100 pieces
296,7
296,7
342,6
342,6
382,5
382,5
422,1
459,7
509,3
545,6
Material:
Helical rods: Copper alloy
Application:
Use of armor rods SB reduces bending stress at clamping points (f.e. suspension clamps) at copper and bronze (copper alloy) conductors. Armor rods don’t have damping
properties.
Armor rods can be used as patch rods up to damages of 25% of the outer layer at suspension points. By this they protect the conductor against damages by arcing foot
points, too.
Mounting instruction:
See instruction-no. 48
Stand: 11. Mai 2007
Pfad: Helical formed fittings/Armor rods/ Armor rods (SB) for copper and bronze conductors/
Gedruckt am: 16. Januar 2012
48 / 53
ONLINE-CATALOGUE
B454/1 Armor splices (SVA) for AAC, AAAC and ACSR conductors
1 ..... Colored center mark
RIBE-Order-No.
Clamping range
Outer diameter
Helical rods
D1
D2
L
Rod dia.
No. of rods
mm
mm
mm
mm
SVA 082 112
8,01 - 8,25
15,7
1120
3,71
8
SVA 098 127
9,36 - 9,86
18,3
1270
4,24
9
SVA 105 132
9,87 - 10,54
19,0
1320
4,24
9
SVA 111 137
10,55 - 11,18
19,7
1370
4,24
9
SVA 119 137
11,19 - 11,94
20,4
1370
4,24
10
SVA 126 142
11,95 - 12,65
21,1
1420
4,24
10
SVA 131 142
12,66 - 13,16
21,6
1420
4,24
11
SVA 136 142
13,17 - 13,64
22,1
1420
4,24
11
SVA 143 152
13,65 - 14,35
23,6
1520
4,62
11
SVA 149 163
14,36 - 14,91
24,3
1630
4,62
11
SVA 158 163
14,92 - 15,88
25,1
1630
4,62
12
SVA 166 170
15,89 - 16,66
25,9
1700
4,62
12
SVA 175 175
16,67 - 17,50
26,7
1750
4,62
12
SVA 179 195
17,51 - 17,93
28,2
1950
5,18
12
SVA 186 195
17,94 - 18,64
29,0
1950
5,18
12
SVA 195 201
18,65 - 19,53
29,9
2010
5,18
13
SVA 203 211
19,54 - 20,32
33,0
2110
6,35
11
SVA 212 213
20,33 - 21,21
33,9
2130
6,35
11
SVA 224 218
21,22 - 22,45
35,2
2180
6,35
12
SVA 235 268
22,46 - 23,57
36,3
2680
6,35
12
SVA 249 274
23,58 - 24,97
37,7
2740
6,35
13
SVA 262 282
24,98 - 26,26
42,0
2820
7,87
11
SVA 276 322
26,27 - 27,69
43,4
3220
7,87
12
SVA 289 348
27,70 - 28,96
44,7
3480
7,87
12
SVA 304 358
28,97 - 30,43
46,2
3580
7,87
13
SVA 321 363
30,44 - 32,13
50,7
3630
9,27
11
SVA 337 378
32,14 - 33,78
52,3
3780
9,27
12
SVA 354 386
33,79 - 35,46
54,0
3800
9,27
13
*) Armor splices consits of single rods with antifriction paste. The paste has to be applicated to the surface of the conductor at installation location.
Weight
Rods per subset
4-4
3-3-3
3-3-3
3-3-3
3-3-4
3-3-4
3-4-4
3-4-4
3-4-4
3-4-4
4-4-4
4-4-4
4-4-4
4-4-4
4-4-4
3-3-3-4
3-4-4
3-4-4
3-3-3-3
3-3-3-3
3-3-3-4
*)
kg/ 100 pieces
28,0
47,5
49,4
47,0
56,9
59,0
64,9
64,9
82,6
88,6
96,6
101,0
101,1
142,0
137,0
148,0
216,0
220,0
223,0
280,0
302,5
444,0
55,35
587,3
610,5
793,3
901,0
940,0
Material:
Helical rods: Aluminium alloy (subsets sanded up to dia. 24,97 mm)
Application:
Armor splices SVA are used at suspension points if
• at AAC or AAAC (see remark) conductors more than 25% of the outer layer and up to 100% of all wires
• at ACSR conductors up to 100% of al. wires, with undamaged steel core
are damaged or destroyed.
Armor splices SVA restore the original mechanical and electrical properties of the conductor.
Assembly to be performed following mounting instruction no.14e in principle.
Mounting instruction:
See instruction no. 14
Remark:
For applying at AACSR please contact the factory.
Stand: 11. Mai 2007
Pfad: Helical formed fittings/Armor rods/ Armor splices (SVA) for AAC, AAAC and ACSR conductors/
Gedruckt am: 16. Januar 2012
49 / 53
ONLINE-CATALOGUE
B454/2 Armor rods (SG) for stranded steel conductors, h.d.g.
1 ..... Colored center mark
RIBE-Order-No.
SG 043 058
SG 046 061
SG 049 064
SG 052 066
SG 055 068
SG 057 071
SG 061 074
SG 065 076
SG 069 079
SG 073 081
SG 078 084
SG 082 085
SG 087 089
SG 094 091
SG 098 094
SG 105 096
SG 110 099
SG 117 102
SG 124 104
SG 132 107
SG 139 109
SG 148 112
Clamping range
D1
Outer diameter
D2
L
Helical rods
Rod dia.
No. of rods
Weight
mm
4,08 - 4,35
4,36 - 4,60
4,61 - 4,90
4,91 - 5,26
5,27 - 5,59
5,60 - 5,79
5,80 - 6,17
6,18 - 6,58
6,59 - 6,94
6,95 - 7,35
7,36 - 7,83
7,84 - 8,28
8,29 - 8,79
8,80 - 9,48
9,49 - 9,88
9,89 - 10,50
10,51 - 11,08
11,09 - 11,77
11,78 - 12,45
12,46 - 13,24
13,25 - 13,99
14,00 - 14,86
mm
7,9
9,0
9,3
9,6
10,0
10,2
10,5
10,9
12,0
12,4
12,9
13,4
13,9
14,6
15,9
16,5
17,1
18,8
19,5
20,3
22,1
22,9
mm
580
610
640
660
680
710
740
760
790
810
840
850
890
910
940
960
990
1020
1040
1070
1090
1120
mm
1,78
2,18
2,18
2,18
2,18
2,18
2,18
2,18
2,54
2,54
2,54
2,54
2,54
2,54
3,02
3,02
3,02
3,51
3,51
3,51
4,04
4,04
9
8
8
8
9
9
10
10
9
10
10
11
11
11
11
11
12
11
12
12
11
12
kg/ 100 pieces
11,8
16,5
17,3
17,9
20,7
21,6
25,0
25,7
32,1
36,6
38,0
42,3
44,2
45,2
65,5
67,0
75,3
95,6
106,3
118,5
136,1
152,6
Material:
Helical rods: Steel/ h.d.g.
Application:
Use of armor rods SG reduces bending stress at clamping points (f.e. suspension clamps) at steel conductors, hot dip galvanized. They have no damping properties.
Armor rods can be used as patch rods up to damages of 25% of the outer layer at suspension points. By this they protect the conductor against damages by arcing foot
points, too.
Mounting instruction:
See instruction-no. 48
Stand: 11. Mai 2007
Pfad: Helical formed fittings/Armor rods/ Armor rods (SG) for stranded steel conductors, h.d.g./
Gedruckt am: 16. Januar 2012
50 / 53
ONLINE-CATALOGUE
B462/1 Spacers (BP) for all types of conductors
RIBE-Order-No.
BP 044 040
BP 063 015
BP 063 050
BP 082 050
BP 117 050
BP 117 060
BP 117 080
BP 136 010
BP 136 050
BP 136 070
Clamping range
D
mm
3,42 - 4,40
4,41 - 6,33
4,41 - 6,33
6,34 - 8,28
8,29 - 11,70
8,29 - 11,70
8,29 - 11,70
11,71 - 13,60
11,71 - 13,60
11,71 - 13,60
Mass
L
mm
200
220
200
260
300
300
300
400
360
360
C
mm
400
150
500
500
500
600
800
100
500
700
S
mm
9,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
12,5
kg/ 100 pieces
20,0
31,0
32,0
37,0
40,0
40,5
41,0
40,0
41,0
42,0
Material:
Helical rod: weather-resistant plastic
Application:
Helically formed spacers fit to all conductor materials. They are designed up to 500 V.
Stand: 21. Juni 2006
Pfad: Helical formed fittings/ Helically formed fittings made from plastic material/ Spacers (BP) for all types of conductors/
Gedruckt am: 16. Januar 2012
51 / 53
ONLINE-CATALOGUE
B463/1 Bird flight diverters (ZP) for marking of AAC, AAAC, ACSR, AACSR, Steel, ACS, Copper and Copper alloy
conductors
RIBE-Order-No.
Drawing number
Clamping range
D
mm
A
mm
L
mm
S
mm
Mass
kg/ 100 pieces
Red color
ZP 111 021 R
ZP 151 026 R
ZP 190 033 R
ZP 230 038 R
ZP 280 053 R
ZP 330 063 R
F 12000/15
F 12000/6
F 12000/2
F 12000/4
F 12001/2
F 12001/4
8,00 - 11,19
11,20 - 15,19
15,20 - 19,09
19,10 - 23,00
23,01 - 28,00
28,01 - 33,00
125
125
125
125
125
125
240
260
330
380
530
630
12,5
12,5
12,5
12,5
12,5
12,5
13,0
14,0
16,0
18,0
24,5
28,5
ZP 151 026 G
ZP 190 033 G
ZP 230 038 G
ZP 280 053 G
ZP 330 063 G
F 12000/5
F 12000/1
F 12000/3
F 12001/1
F 12001/3
11,20 - 15,19
15,20 - 19,09
19,10 - 23,00
23,01 - 28,00
28,01 - 33,00
125
125
125
125
125
260
330
380
530
630
12,5
12,5
12,5
12,5
12,5
14,0
16,0
18,0
24,5
28,5
ZP 111 021 W
ZP 151 026 W
ZP 190 033 W
ZP 230 038 W
ZP 280 053 W
ZP 330 063 W
F 12000/13
F 12000/9
F 12000/8
F 12000/7
F 12001/5
F 12001/7
8,0 - 11,19
11,20 - 15,19
15,20 - 19,09
19,10 - 23,00
23,01 - 28,00
28,01 - 33,00
125
125
125
125
125
125
240
260
330
380
530
630
12,5
12,5
12,5
12,5
12,5
12,5
13,0
14,0
16,0
18,0
24,5
28,5
ZP 111 021 S
ZP 151 026 S
ZP 190 033 S
ZP 230 038 S
ZP 280 053 S
ZP 330 063 S
F 12000/14
F 12000/10
F 12000/11
F 12000/12
F 12001/6
F 12001/8
8,00 - 11,19
11,20 - 15,19
15,20 - 19,09
19,10 - 23,00
23,01 - 28,00
28,01 - 33,00
125
125
125
125
125
125
240
260
330
380
530
630
12.5
12,5
12,5
12,5
12,5
12,5
13,0
14,0
16,0
18,0
24,5
28,5
Grey color
White color
Black color
Material:
Helical rod: PVC rigid, bare
Application:
Bird flight diverters ZP are used for marking of conductors and cables to prevent bird collisions.
Easy installation by wrapping the spiral around the rope without any tool.
Stand: 11. Mai 2007
Pfad: Helical formed fittings/ Helically formed fittings made from plastic material/ Bird flight diverters (ZP) for marking of AAC, AAAC, ACSR, AACSR, Steel, ACS, Copper and Copper alloy conductors/
Gedruckt am: 16. Januar 2012
52 / 53
ONLINE-CATALOGUE
B463/2 Bird flight diverters (MP/MPH) for marking of AAC, AAAC, ACSR, AACSR, Steel, ACS, Copper and
Copper alloy conductors
RIBE-Order-No.
Drawing number
Fig.
Clamping range
D1
Mass
L1
L2
D2
kg/ 100 pieces
Red color
MP 151 053 R
MP 190 064 R
MP 230 078 R
F 12037-10/1
F 12037-10/2
F 12037-10/3
1
1
1
11,20 - 15,19
15,20 - 18,99
19,00 - 23,00
530
640
780
500
500
500
12,5
12,5
12,5
20,0
21,0
22,5
MPH 151 053 R
MPH 190 064 R
MPH 230 078 R
F 12037/1
F 12037/2
F 12037/3
2
2
2
11,20 - 15,19
15,20 - 18,99
19,00 - 23,00
530
640
780
500
500
500
12,5
12,5
12,5
21,0
22,0
23,5
MPH 151 053 W
MPH 190 064 W
MPH 230 078 W
F 12037-30/1
F 12037-30/2
F 12037-30/3
2
2
2
11,20 - 15,19
15,20 - 18,99
19,00 - 23,00
530
640
780
500
500
500
12,5
12,5
12,5
21,0
22,0
23,5
MPH 151 053 S
MPH 190 064 S
MPH 230 078 S
F 12037-20/1
F 12037-20/2
F 12037-20/3
2
2
2
11,20 - 15,19
15,20 - 18,99
19,00 - 23,00
530
640
780
500
500
500
12,5
12,5
12,5
21,0
22,0
23,5
Red color
White color
Black color
Material:
Helical rod: PVC rigid, bare
Application:
Bird flight diverters MP/MPH are used for marking of conductors and cables to prevent bird collisions. We recommend to use 3 diverters in “Mercedes"-star configuration.
Easy installation by wrapping the spiral around the rope without any tool.
Stand: 21. Juni 2006
Pfad: Helical formed fittings/ Helically formed fittings made from plastic material/ Bird flight diverters (MP/MPH) for marking of AAC, AAAC, ACSR, AACSR, Steel, ACS, Copper and Copper alloy conduc
Gedruckt am: 16. Januar 2012
53 / 53
Download