Helical Fittings EXCLUSIVE AUSTRALIAN DISTRIBUTORS ONLINE-CATALOGUE B4/1 Introduction in helical fittings Helical fittings are composed of single helical rods which -according to the respective application - are separate or preassembled, straight or looped on delivery. Helical fittings involve such a variety of applications that still nowadays, it cannot be forseen for which applications of everyday life they can be used too. This catalogue volume B4 in respect of the application of helical fittings mainly refers to electrical engineering and especially to the use on overhead lines and distribution systems. Preformed accessories can be used to tension, to suspend and to connect conductors, cables, glass fiber rods and also solid rods as for instance guys. In addition preformed accessories are employed to protect or to repair conductors, for attachment to post insulators, as spacers on bundled conductors and for tensioning the suspension of street lighting. They are also successfully used to mark conductors against collision of birds with them (bird flight diverters). Preformed accessories have very successfully been used since 1950. The employment of helical fittings is not at all limited to overhead lines only. Preformed accessories in a large measure are also used for the construction of antennas, radar stations etc. The helical fittings included in this catalogue volume have introduced a new design in Germany which distinguishes by its simplicity and reliability. The Richard Bergner Company has started the production of helical fittings in 1959 and in the meantime, the helically fittings designs have been adapted to the specific requirements in Germany and Europe. The effect of helical fittings is mostly based on the principle of development of a low unit pressure over a large area: The inside diameter of the unloaded helical rods is slightly smaller than the outside diameter of conductor, cable or solid rod. By wrapping the helical rods on a conductor, a spring tension is created producing the necessary frictional contact. This spring tension is of elastic nature and ensures a constant gripping. If conductor, cable or solid rod are subject to tension load, the gripping force increases as the tension load increases. The inside of helical rods may be sanded or the conductor surface be covered with a friction bond to improve the contact. The gripping force in any case is so high that under tension load - correct dimensioning provided rather the conductor fails than the fitting. To ensure the full performance, the helical fitting must exactly be adapted to the outside diameter of conductor, cable or solid rod. In addition, helical fitting and outer strand of conductor must be of same lay direction. Unless specified otherwise, helical fittings are of right-hand lay on delivery. Hence, it is necessary to specify on order if helical fittings for left-hand lay conductors are required. In general, helical fittings are made from a material similar to that of conductor or solid rod providing thus a corrosion resistance of fitting equal to that of conductor or rod. The helical rods can be installed without use of any tool. Incorrect assembly is almost impossible. It can be detected by eyesight whether accessory was correctly installed. Hence, helical fittings can be installed by unskilled workers. Mounting instructions are available on demand (see also catalogue). Helical fittings are provided with a label stating for which funtion and for what conductors, cables or solid rods the respective accessory is designed for. In addition you find data of production on it securing actions according to DIN EN ISO 9001. It is recommended to remove this label only immediately before assembly or better - if possible - don’t remove it. The label is weather-resisting and will still be legible if it has been exposed to the open air for a longer time. Helical fittings are largely protected by patents or registration of designs. In case that helical fittings are required for applications not specified in this catalogue a specific enquiry is requested. Helical fittings can be used: - to tension - to suspend - to fix - to splice - to repair - to armor - to protect against damage at - to protect against abrasion at - to reduce stress at - to mark - to space - to damp vibrations - to pull (installation) - to shunt weak splices at - as interphase spacer at - to rise diameter of stranded conductors, cables and solid conductors. Stand: 19. Juni 2006 Pfad: Helical formed fittings/ Introduction/ Introduction in helical fittings/ Gedruckt am: 16. Januar 2012 1 / 53 ONLINE-CATALOGUE B4/2 Composition of identification numbers Remark: Introduction in composition of identification numbers see catalogue sheet B8/8. Stand: 19. Juni 2006 Pfad: Helical formed fittings/ Introduction/ Composition of identification numbers/ Gedruckt am: 16. Januar 2012 2 / 53 ONLINE-CATALOGUE B403/1 Helical dead-ends (AB) for solid and stranded copper conductors 1 ..... Helical dead-end 2 ..... Thimble 3 ..... Black crossing mark Clamping range Helical rods Loop Mass Thimble RIBE-Order-No. AB 026 030 AB 027 031 AB 028 033 AB 030 034 AB 031 035 AB 033 037 AB 034 038 AB 036 039 AB 037 040 AB 039 042 AB 041 042 AB 042 043 AB 044 044 AB 046 045 AB 048 047 AB 050 048 AB 053 049 AB 055 051 AB 057 052 AB 060 053 AB 062 057 AB 065 058 AB 068 061 AB 071 063 AB 074 066 AB 077 067 AB 081 068 AB 084 070 AB 088 071 AB 091 073 AB 095 076 AB 099 078 AB 104 081 AB 108 084 D1 L S No. of rods D2 mm 2,54 - 2,64 2,65 - 2,77 2,78 - 2,89 2,90 - 3,02 3,03 - 3,15 3,16 - 3,30 3,31 - 3,45 3,46 - 3,61 3,62 - 3,76 3,77 - 3,94 3,95 - 4,11 4,12 - 4,29 4,30 - 4,47 4,48 - 4,67 4,68 - 4,88 4,89 - 5,08 5,09 - 5,31 5,32 - 5,54 5,55 - 5,77 5,78 - 6,02 6,03 - 6,27 6,28 - 6,55 6,56 - 6,83 6,84 - 7,14 7,15 - 7,44 7,45 - 7,77 7,78 - 8,10 8,11 - 8,46 8,47 - 8,81 8,82 - 9,19 9,20 - 9,58 9,59 - 9,98 9,99 - 10,41 10,42 - 10,85 mm 300 310 330 340 350 370 380 390 400 420 420 430 440 450 470 480 490 510 520 530 570 580 610 630 660 675 680 700 710 730 760 780 810 840 mm 1,62 1,62 1,48 1,48 1,48 1,48 1,48 1,62 1,62 1,62 1,48 1,48 1,48 1,62 1,62 1,62 1,83 1,83 1,83 1,83 2,18 2,18 2,18 2,39 2,39 2,59 2,59 2,89 2,89 2,89 2,89 3,25 3,25 3,25 mm 3 3 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 mm 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 Stand: 25. November 2010 Pfad: Helical formed fittings/ Helical dead ends/ Helical dead-ends (AB) for solid and stranded copper conductors/ Gedruckt am: 16. Januar 2012 RIBE-No. kg/ 100 pieces 3,6 3,8 4,4 4,5 4,7 4,9 5,1 6,3 6,4 6,7 7,0 7,2 7,3 9,0 9,4 9,6 12,5 13,0 13,3 13,5 20,7 21,0 22,1 27,4 28,7 34,3 34,8 44,6 45,2 46,5 48,4 62,7 65,2 67,6 F 2684/3 3 / 53 ONLINE-CATALOGUE Clamping range Helical rods Loop Mass Thimble RIBE-Order-No. AB 112 085 AB 116 086 AB 121 087 AB 125 089 AB 129 094 AB 132 095 AB 136 096 AB 140 097 AB 144 099 AB 150 101 AB 157 105 AB 163 108 AB 170 114 AB 177 118 AB 185 122 AB 192 129 AB 200 134 AB 209 137 AB 217 146 AB 227 150 D1 L S No. of rods D2 mm 10,86 - 11,25 11,26 - 11,66 11,67 - 12,10 12,11 - 12,57 12,58 - 12,90 12,91 - 13,28 13,29 - 13,67 13,68 - 14,07 14,08 - 14,48 14,49 - 15,09 15,10 - 15,72 15,73 - 16,38 16,39 - 17,07 17,08 - 17,78 17,79 - 18,52 18,53 - 19,28 19,29 - 20,09 20,10 - 20,93 20,94 - 21,79 21,80 - 22,71 mm 850 860 870 890 940 950 960 970 990 1010 1050 1080 1140 1180 1220 1290 1340 1370 1460 1500 mm 3,66 3,66 3,66 3,66 3,66 3,66 3,66 3,66 3,66 4,11 4,11 4,11 4,62 4,62 4,62 5,18 5,18 5,18 5,82 5,82 mm 5 5 5 5 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 mm 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 58 RIBE-No. kg/ 100 pieces 86,7 87,8 88,8 90,8 115,1 116,3 117,5 118,8 121,2 155,9 162,1 166,7 222,5 230,2 238,1 316,4 328,6 336,1 452,1 464,4 F 2685/3 Material: Helical rods: Copper alloy Application: Helical dead-ends (AB) can be used for full load tensioning of solid and stranded copper-conductors together with clevis thimbles (see page B821).Thimbles have to be ordered separately. Please state if dead-ends for left-hand lay conductors are required. The dead-ends are furnished bent as loops with the rods glued together to a bundle. The inside surfaces are gritted. A coloured cross-over mark near the loop indicates the starting point of application. Attention! They lay direction of both the dead-ends and the outer layer of the conductor must be the same. Mounting instruction: See mounting instruction no. 9 Stand: 25. November 2010 Pfad: Helical formed fittings/ Helical dead ends/ Helical dead-ends (AB) for solid and stranded copper conductors/ Gedruckt am: 16. Januar 2012 4 / 53 ONLINE-CATALOGUE B404/1 Helical dead-ends (AG) for solid and stranded hot dip galvanized steel conductors and glass fiber rods 1 ..... Helical dead-end 2 ..... Thimble 3 ..... Black crossing mark RIBE-Order-No. AG 026 025 AG 027 026 AG 029 028 AG 030 029 AG 032 030 AG 033 033 AG 035 035 AG 036 038 AG 038 040 AG 040 043 AG 041 044 AG 044 046 AG 046 048 AG 048 052 AG 050 052 AG 052 053 AG 054 055 AG 056 056 AG 059 057 AG 062 061 AG 064 062 AG 067 064 AG 070 066 AG 073 067 AG 076 069 AG 079 071 AG 082 074 AG 085 076 AG 089 077 AG 093 079 AG 096 081 AG 100 084 AG 104 086 AG 108 088 AG 111 089 Clamping range D1 L mm 2,54 - 2,64 2,65 - 2,77 2,78 - 2,90 2,91 - 3,05 3,06 - 3,20 3,21 - 3,35 3,36 - 3,50 3,51 - 3,66 3,67 - 3,84 3,85 - 4,01 4,02 - 4,19 4,20 - 4,40 4,41 - 4,60 4,61 - 4,80 4,81 - 5,00 5,01 - 5,23 5,24 - 5,46 5,47 - 5,69 5,70 - 5,94 5,95 - 6,20 6,21 - 6,45 6,46 - 6,73 6,74 - 7,01 7,02 - 7,32 7,33 - 7,62 7,63 - 7,95 7,96 - 8,28 8,29 - 8,58 8,59 - 8,95 8,96 - 9,30 9,31 - 9,68 9,69 - 10,06 10,07 - 10,45 10,46 - 10,80 10,81 - 11,10 mm 250 250 260 270 290 300 310 310 330 350 360 410 480 500 500 500 520 530 540 580 590 610 660 630 650 710 740 760 770 790 810 840 860 880 890 Helical rods S mm 1,30 1,30 1,30 1,30 1,30 1,55 1,55 1,55 1,55 1,78 1,78 1,78 2,18 2,18 2,18 1,78 1,78 1,78 1,78 2,18 2,18 2,18 2,18 2,54 2,54 2,54 2,54 3,02 3,02 2,54 2,54 3,02 3,02 3,02 3,02 Loop D2 Mass No. of rods 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 5 5 5 5 5 5 6 6 5 5 6 6 mm 38 38 38 38 38 38 38 38 38 38 38 38 44 44 44 44 44 44 44 44 44 44 50 50 50 50 50 50 50 50 50 50 50 64 64 kg/ 100 pieces 1,9 2,0 2,1 2,7 2,9 4,3 4,3 4,3 4,6 6,3 6,5 7,7 13,0 13,6 13,6 11,2 11,7 11,9 12,1 19,6 20,0 20,7 22,3 28,5 29,4 32,1 33,4 48,2 48,8 42,8 43,9 53,2 54,5 66,9 67,7 Stand: 08. Mai 2007 Pfad: Helical formed fittings/ Helical dead ends/ Helical dead-ends (AG) for solid and stranded hot dip galvanized steel conductors and glass fiber rods/ Gedruckt am: 16. Januar 2012 Thimble RIBE-No. F 2684/3 5 / 53 ONLINE-CATALOGUE RIBE-Order-No. AG 114 090 AG 117 091 AG 120 094 AG 125 100 AG 130 102 AG 135 104 AG 139 107 AG 145 119 AG 151 122 AG 157 124 AG 163 127 AG 168 129 Clamping range D1 L mm 11,11 - 11,45 11,46 - 11,75 11,76 - 12,05 12,06 - 12,55 12,56 - 13,05 13,06 - 13,50 13,51 - 13,94 13,95 - 14,53 14,54 - 15,15 15,16 - 15,75 15,76 - 16,36 16,37 - 16,80 mm 900 910 940 1000 1020 1040 1070 1190 1220 1240 1270 1290 Helical rods S mm 3,02 3,51 3,51 3,51 3,51 4,04 4,04 4,04 4,04 4,37 4,37 4,37 Loop D2 Mass No. of rods 6 5 5 6 6 5 5 6 6 6 6 6 mm 64 64 64 64 64 64 64 64 64 64 64 64 kg/ 100 pieces 68,4 71,5 80,1 120,0 104,0 118,0 122,0 162,0 166,0 197,0 202,0 205,0 Thimble RIBE-No. F 2685/3 Material: Helical rods: Steel, h.d.g. (inside surfaces gritted) Application: Helical dead-ends (AG) can be used for full load tensioning of solid and stranded hot dip galvanized steel-conductors and glass fiber rods. Check the breaking load of clevis thimbles (see page B821). Thimbles have to be ordered separately. Please state if dead-ends for left-hand lay conductors are required. The dead-ends are furnished bent as loops with the rods glued together to a bundle.The inside surfaces are gritted. A coloured cross-over mark near the loop indicates the starting point of application. Attention! They lay direction of both the dead-ends and the outerlayer of the conductor must be the same. Mounting instruction: See mounting instruction no. 9 Stand: 08. Mai 2007 Pfad: Helical formed fittings/ Helical dead ends/ Helical dead-ends (AG) for solid and stranded hot dip galvanized steel conductors and glass fiber rods/ Gedruckt am: 16. Januar 2012 6 / 53 ONLINE-CATALOGUE B405/1 Helical dead-ends (AH) for stainless steel conductors and glass fiber rods 1 ..... Helical dead-end 2 ..... Thimble 3 ..... Black crossing mark RIBE-Order-No. AH 050 052 AH 056 037 *) AH 059 058s *) AH 062 061s AH 070 066 AH 079 071 AH 089 058 *) AH 093 092 AH 101 070 AH 117 091 AH 121 081 Clamping range D1 mm 4,81 - 5,00 5,01 - 5,69 5,70 - 5,94 5,95 - 6,20 6,74 - 7,01 7,63 - 7,95 8,61 - 8,92 8,93 - 9,32 9,74 - 10,14 11,46 - 11,75 11,76 - 12,16 L mm 520 380 580 610 660 710 580 920 705 910 810 Helical rods S No. of mm rods 2,03 2,03 2,03 2,56 2,18 2,56 3,05 3,05 3,05 3,53 3,53 4 5 5 4 5 5 5 5 5 5 5 Loop D2 44 50 50 44 50 50 50 58 50 64 64 Mass. Thimble RIBE-No. kg/ 100 pcs 11,6 10,7 15,2 22,0 21,0 31,0 36,7 54,0 44,0 75,0 68,7 F 2684/3 F 2685/3 *) only for glass fiber rods Material: Helical rods: Stainless steel (inside surfaces gritted) Application: Helical dead-ends (AH) can be used for full load tensioning of stranded stainless steel conductors and glass fiber rods. Check the breaking load of clevis thimbles (see page B821). Thimbles have to be ordered separately. Please state if dead-ends for left-hand lay conductors are required. The dead-ends are furnished bent as loops with the rods glued together to a bundle. The inside surfaces are gritted. A coloured cross-over mark near the loop indicates the starting point of application. Attention! They lay direction of both the dead-ends and the outerlayer of the conductor must be the same. Mounting instruction: See mounting instruction no. 9 Stand: 10. August 2006 Pfad: Helical formed fittings/ Helical dead ends/ Helical dead-ends (AH) for stainless steel conductors and glass fiber rods/ Gedruckt am: 16. Januar 2012 7 / 53 ONLINE-CATALOGUE B406/1 Helical dead-ends (AW) for Alumoweld conductors and ACSR Remark: See catalogue sheet B811 Stand: 10. August 2006 Pfad: Helical formed fittings/ Helical dead ends/ Helical dead-ends (AW) for Alumoweld conductors and ACSR/ Gedruckt am: 16. Januar 2012 8 / 53 ONLINE-CATALOGUE B408/1 Thimbles Remark: See catalogue sheet B821. Stand: 10. August 2006 Pfad: Helical formed fittings/ Helical dead ends/Thimbles/ Gedruckt am: 16. Januar 2012 9 / 53 ONLINE-CATALOGUE B411/1 Armour grip suspensions without attachment for shunts Remark: See catalogue sheet B801/3. Stand: 10. August 2006 Pfad: Helical formed fittings/ Armour grip suspensions/ Armour grip suspensions without attachment for shunts/ Gedruckt am: 16. Januar 2012 10 / 53 ONLINE-CATALOGUE B411/3 Armour grip suspensions with attachment for shunts Remark: See catalogue sheet B801/4. Stand: 10. August 2006 Pfad: Helical formed fittings/ Armour grip suspensions/ Armour grip suspensions with attachment for shunts/ Gedruckt am: 16. Januar 2012 11 / 53 ONLINE-CATALOGUE B421/1 Line splices (VAG) for ACSR and AACSR conductors with 2 layers Fig. 2: Mounting of aluminium splice Fig.1: Mounting of steel splice S1 ..... Steel splice S2 ..... Aluminium splice 1 ....... Steel core 2 ....... Aluminium outer layer 3 ....... Colored center mark RIBE-Order-No. Nominal cross section Type of helical rods Fig. mm² VAG 054 079 16/2,5 VAG 068 096 25/4 VAG 112 168 44/32 VAG 117 168 50/30 VAG 160 224 95/55 VAG 175 265 105/75 VAG 180 251 120/70 Steel splice Aluminium splice Steel splice Aluminium splice Steel splice Aluminium splice Steel splice Aluminium splice Steel splice Aluminium splice Steel splice Aluminium splice Steel splice Aluminium splice 1 2 1 2 1 2 1 2 1 2 1 2 1 2 L mm 350 790 400 960 610 1680 660 1680 840 2240 1200 2650 940 2510 D mm 1,78 2,18 2,18 2,38 1,78 3,45 2,18 3,45 3,02 4,24 3,02 5,18 3,51 5,18 Helical rods No. of rods Weight Rods per subset kg/ 100 pieces 5 9 6 10 13 11 11 11 11 13 12 11 10 12 2-3 3-3-3 2-2-2 5-5 4-4-5 3-4-4 3-4-4 3-4-4 3-4-4 4-4-5 4-4-4 3-4-4 3-3-4 4-4-4 10,7 18,2 68,8 67,3 179,6 272,0 266,9 Material: Splice for steel core: Steel/ h.d.g. (blue mark, inside surfaces gritted) Filler splice: Aluminium alloy (black mark, non-gritted) Splice for aluminium: Aluminium alloy (green mark, inside surfaces gritted) Application: Line splices VAG are used as full tension splices for connecting ACSR or AACSR (see remark) conductors. Line splices consist of 2 to 4 sets of spirals, coloured differently: - splice for steel core - if necessary 1 or 2 filler spirals to fill the gap between diameter of steel splice and outer diameter of conductor - splice for aluminium layers The sets with same marking belong together: Stand: 07. Juli 2008 Pfad: Helical formed fittings/ Line splices/ Line splices (VAG) for ACSR and AACSR conductors with 2 layers/ Gedruckt am: 16. Januar 2012 12 / 53 ONLINE-CATALOGUE Attention! The lay direction of the line spices has to be equal the lay direction of the outside cable layer. For repair purpose you also can use line splices in parts (e. g. use only the green marked splice for aluminium). Mounting instruction: 1. Straighten the ends of the conductor, tie them together and cut them off straight-line. 2. Uncover the steel core by removing the aluminium strands at liberally half the length of the line splice for the steel core (blue mark). Attention: do not damage the steel core. 3. Tie the ends of the steel core and the aluminium strands together securely. 4. Clean the aluminium strands at both ends at liberally half the length of the green marked line splice for the aluminium coat. For this purpose we recommend using a wire scratch brush, e.g. according to sheet B198/1. 5. Mounting the line splice Place the first set of rods of the steel core line splice (blue mark) with the colour mark at the end of the steel of one conductor and coil it up. 6. Mounting becomes easier when you start coiling up the set with some distance from the end of the steel core. However you have to pay attention that the set’s blue mark is in accordance with the end of the steel core after coiling up. Place the end of the steel core of the second conductor on the centre mark of the rod set and coil it up as well. There should be a small air gap between the ends of the steel cores. Coil up the remaining sets as well, in the same way, starting near the steel core joint. If the sets consist of an unequal number of rods, the set with the smallest number of rods should be coiled up at last. The filler rods (black mark) have to be coiled up the same way. The blue and the black marks have to align with each other. If there is a difference in diameter between the steel core and the aluminium outside layer it is necessary to attach two filler rods according to the indications in the table. with a rod diameter of ≤ 6,35 mm for the line splice for the aluminium coat Place the first set of rods starting from the conductor joint in a way that the green and the black mark align with each other. Coil up the set on one side, and on the other side subsequently. Place the second set close to the first one and coil it up onto the conductor in a parallel way to the first set. The same procedure has to be carried out with the remaining sets. with a rod diameter of ≥ 7,87 mm for the line splice for the aluminium coat Apply a thin but closed layer of the antifriction paste on the conductor surface. The antifriction paste can be applied by hand or with a paint brush. Place the first rod with the green mark on the black mark of the filler rod and coil it up on one side and after that on the other side. The same procedure has to be carried out with the remaining rods, whereas the rods have to be close to each other. Cleaning the line splice. For this purpose we recommend using a wire scratch brush, e.g. according to sheet B198/1. Dismantling: Removal and subsequent reuse are not allowed. Remark: For applying at AACSR please contact the company. Stand: 07. Juli 2008 Pfad: Helical formed fittings/ Line splices/ Line splices (VAG) for ACSR and AACSR conductors with 2 layers/ Gedruckt am: 16. Januar 2012 13 / 53 ONLINE-CATALOGUE B421/2 Line splices (VAG) for ACSR and AACSR conductors with 3 or 4 layers Fig. 1: Mounting of steel splice Fig. 2: Mounting of filler splice Fig. 3: Mounting of aluminium splice S1 ..... Steel splice S2 ..... Filler splice S3 ..... Aluminium splice 1 ....... Steel core 2 ....... Aluminium inner layer 3 ....... Aluminium outer layer 4 ....... Colored center mark RIBE-Order-No. Nominal cross section Type of spiral Fig. mm² VAG081114 35/6 VAG090132 42/7 VAG096119 50/8 67,43/11,28 Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice 1 2 3 1 2 3 1 2 3 1 L mm 410 410 1140 300 300 1320 330 330 1190 410 D mm 1,30 1,30 2,59 1,30 1,82 2,59 1,30 1,83 3,07 1,78 Stand: 06. Dezember 2010 Pfad: Helical formed fittings/ Line splices/ Line splices (VAG) for ACSR and AACSR conductors with 3 or 4 layers/ Gedruckt am: 16. Januar 2012 Helical rods No. of rods Weight Rods per subset kg/ 100 pieces 7 13 11 8 10 12 8 11 11 8 3-4 4-4-5 3-4-4 4-4 5-5 4-4-4 4-4 3-4-4 3-4-4 4-4 27,0 30,0 32,9 14 / 53 ONLINE-CATALOGUE RIBE-Order-No. Nominal cross section VAG113140 mm² 66,27/11,04 Quail,d=11,34mm VAG117162 70/12 VAG136190 95/15 VAG145200 110/22 Hyena,d=14,57mm VAG155216 120/20 VAG161231 125/30 VAG163224 135/22 Partridge,d=16,28mm VAG171244 150/25 VAG189272 170/40 VAG190282 185/30 VAG203289 210/35 VAG210275 230/30 VAG210302 210/50 VAG219305 240/40 VAG225310 265/35 VAG245325 300/50 VAG205345 340/30 VAG266390 310/100 VAG266429 360/60 VAG267390 385/35 VAG270425 380/50 VAG280482 340/110 VAG288432 435/55 Type of spiral Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice 2 Filler splice 1 Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice 2 Filler splice 1 Aluminium splice Steel splice Filler splice 2 Filler splice 1 Aluminium splice Steel splice Filler splice Aluminium splice Steel splice Filler splice 2 Filler splice 1 Fig. 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 2 3 1 2 3 1 2 3 1 2 2 3 1 2 2 3 1 2 3 1 2 2 L mm 410 1400 430 430 1620 457 457 1900 530 530 2000 530 530 2160 606 660 2310 610 610 2240 630 630 2440 760 760 2720 680 680 2820 700 700 2890 630 630 2750 790 790 3020 736 736 3050 710 710 3100 790 790 3250 710 710 710 3450 1100 1100 3900 1040 1040 4290 710 710 710 3900 840 840 840 4250 1420 1420 4820 860 860 860 D mm 1,82 3,45 1,78 1,83 3,45 1,78 2,39 4,24 1,78 2,38 4,62 1,78 3,07 4,24 2,18 2,38 4,24 1,78 3,07 4,62 2,18 3,07 5,18 3,02 2,38 5,18 2,54 3,45 6,35 2,54 3,71 6,35 2,18 4,24 6,35 2,54 3,45 6,35 2,54 4,24 6,35 2,54 4,24 6,35 2,54 5,18 6,35 2,54 3,07 3,07 7,87 3,56 3,07 7,87 3,02 5,18 7,87 2,54 3,07 3,70 7,87 2,54 3,07 3,71 7,87 4,04 3,07 7,87 3,02 3,07 3,45 Stand: 06. Dezember 2010 Pfad: Helical formed fittings/ Line splices/ Line splices (VAG) for ACSR and AACSR conductors with 3 or 4 layers/ Gedruckt am: 16. Januar 2012 Helical rods No. of rods 13 11 8 14 11 9 12 11 11 12 11 11 11 12 11 15 13 11 11 12 10 12 11 9 18 12 10 12 11 10 12 11 10 10 11 12 13 11 11 11 12 10 11 12 12 10 13 10 13 18 10 12 20 12 11 11 12 10 14 16 12 12 14 16 12 11 22 12 11 16 20 Weight Rods per subset 4-4-5 3-4-4 4-4 3-3-4-4 3-4-4 3-3-3 4-4-4 3-3-3 3-4-4 4-4-4 3-4-4 3-4-4 3-4-4 4-4-4 3-4-4 5-5-5 4-4-5 3-4-4 3-4-4 4-4-4 5-5 4-4-4 3-4-4 3-3-3 4-4-5-5 4-4-4 5-5 4-4-4 3-4-4 5-5 4-4-4 3-4-4 3-3-4 3-3-4 3-4-4 4-4-4 4-4-5 3-3-4 3-4-4 3-4-4 4-4-4 5-5 3-4-4 3-3-3-3 4-4-4 3-3-4 4-4-5 5-5 3-3-3-4 4-4-5-5 *) 3-3-3-3 5-5-5-5 *) 3-4-4 3-4-4 *) 5-5 3-3-4-4 4-4-4-4 *) 4-4-4 4-5-5 4-4-4-4 *) 3-4-4 4-4-4-5-5 *) 3-4-4 4-4-4-4 5-5-5-5 kg/ 100 pieces 60,0 61,6 103,3 128,0 133,5 162,7 165,0 204,3 264,0 342,7 355,5 337,0 380,6 411,0 403,0 476,7 603,0 819,0 850,0 711,0 829,3 1048,0 864,7 15 / 53 ONLINE-CATALOGUE RIBE-Order-No. Nominal cross section Type of spiral Fig. Helical rods Weight L D No. of rods Rods per subset mm² mm mm kg/ 100 pieces Aluminium splice 3 4320 7,87 12 *) Steel splice 1 890 3,07 11 3-4-4 VAG306460 490/65 Filler splice 2 2 890 3,45 14 4-5-5 990,9 Filler splice 1 2 890 3,71 18 4-4-5-5 Aluminium splice 3 4600 7,87 13 *) Steel splice 1 790 2,54 12 4-4-4 VAG322480 560/50 Filler splice 2 2 790 3,07 14 4-5-5 1274,4 Filler splice 1 2 790 6,35 11 3-4-4 Aluminium splice 3 4800 9,27 12 *) Steel splice 1 960 3,02 12 4-4-4 VAG328530 564/72 Filler splice 2 2 962 3,45 14 4-5-5 1420,0 Finch Filler splice 1 2 960 4,62 15 5-5-5 Aluminium splice 3 5300 9,27 12 *) Steel splice 1 1040 3,51 11 3-4-4 VAG361532 680/83, 680/85, Filler splice 2 2 1040 3,45 16 4-4-4-4 1590,0 685/87 Filler splice 1 2 1040 5,18 16 4-4-4-4 Aluminium splice 3 5320 9,27 13 *) *) Armor splices consist of single rods with antifriction paste. The paste has to be applicated to the surface of the conductor at installation location. The antifriction paste is part of delivery. Material: Splice for steel core: Steel/ h.d.g. (blue mark, inside surfaces gritted) Filler splice: Aluminium alloy (black mark, non-gritted) Splice for aluminium: Aluminium alloy (green mark, inside surfaces gritted) Application: Line splices VAG are used as full tension splices for connecting ACSR or AACSR (see remark) conductors. Line splices consist of 2 to 4 sets of spirals, coloured differently: - splice for steel core - if necessary 1 or 2 filler spirals to fill the gap between diameter of steel splice and outer diameter of conductor - splice for aluminium layers The sets with same marking belong together: Attention! The lay direction of the line spices has to be equal the lay direction of the outside cable layer. For repair purpose you also can use line splices in parts (e. g. use only the green marked splice for aluminium). Mounting instruction: 1. Straighten the ends of the conductor, tie them together and cut them off straight-line. 2. Uncover the steel core by removing the aluminium strands at liberally half the length of the line splice for the steel core (blue mark). Attention: do not damage the steel core. 3. Tie the ends of the steel core and the aluminium strands together securely. 4. Clean the aluminium strands at both ends at liberally half the length of the green marked line splice for the aluminium coat. For this purpose we recommend using a wire scratch brush, e.g. according to sheet B198/1. 5. Mounting the line splice Place the first set of rods of the steel core line splice (blue mark) with the colour mark at the end of the steel of one conductor and coil it up. Mounting becomes easier when you start coiling up the set with some distance from the end of the steel core. However you have to pay attention that the set’s blue mark is in accordance with the end of the steel core after coiling up. Place the end of the steel core of the second conductor on the centre mark of the rod set and coil it up as well. There should be a small air gap between the ends of the steel cores. Coil up the remaining sets as well, in the same way, starting near the steel core joint. If the sets consist of an unequal number of rods, the set with the smallest number of rods should be coiled up at last. The filler rods (black mark) have to be coiled up the same way. The blue and the black marks have to align with each other. If there is a difference in diameter between the steel core and the aluminium outside layer it is necessary to attach two filler rods according to the indications in the table. with a rod diameter of ≤ 6,35 mm for the line splice for the aluminium coat Place the first set of rods starting from the conductor joint in a way that the green and the black mark align with each other. Coil up the set on one side, and on the other side subsequently. Place the second set close to the first one and coil it up onto the conductor in a parallel way to the first set. The same procedure has to be carried out with the remaining sets. with a rod diameter of ≥ 7,87 mm for the line splice for the aluminium coat Apply a thin but closed layer of the antifriction paste on the conductor surface. The antifriction paste can be applied by hand or with a paint brush. Place the first rod with the green mark on the black mark of the filler rod and coil it up on one side and after that on the other side. The same procedure has to be carried out with the remaining rods, whereas the rods have to be close to each other. Stand: 06. Dezember 2010 Pfad: Helical formed fittings/ Line splices/ Line splices (VAG) for ACSR and AACSR conductors with 3 or 4 layers/ Gedruckt am: 16. Januar 2012 16 / 53 ONLINE-CATALOGUE 6. Cleaning the line splice. For this purpose we recommend using a wire scratch brush, e.g. according to sheet B198/1. Dismantling: Removal and subsequent reuse are not allowed. Remark: For applying at AACSR please contact the company. Stand: 06. Dezember 2010 Pfad: Helical formed fittings/ Line splices/ Line splices (VAG) for ACSR and AACSR conductors with 3 or 4 layers/ Gedruckt am: 16. Januar 2012 17 / 53 ONLINE-CATALOGUE B422/1 Line splices (VA) for AAC conductors 1 ..... Colored center mark RIBE-Order-Nor. Clamping range D1 Helical rods L Dia. of rods Numbers mm mm mm VA 040 046 3,92 - 4,09 460 2,18 7 VA 042 048 4,10 - 4,27 480 2,18 7 VA 044 048 4,28 - 4,47 480 2,18 8 VA 046 053 4,49 - 4,67 530 2,18 8 VA 049 053 4,68 - 4,90 530 2,18 8 VA 051 053 4,91 - 5,13 530 2,18 8 VA 053 056 5,14 - 5,38 560 2,18 9 VA 055 056 5,39 - 5,56 560 2,18 9 VA 057 058 5,57 - 5,79 580 2,18 9 VA 060 061 5,80 - 6,07 610 2,18 10 VA 062 063 6,08 - 6,25 630 2,39 9 VA 065 066 6,26 - 6,53 660 2,39 9 VA 068 066 6,57 - 6,86 660 2,39 10 VA 071 068 6,87 - 7,11 680 2,39 10 VA 073 071 7,12 - 7,34 710 2,39 10 VA 075 071 7,35 - 7,57 710 2,39 11 VA 078 076 7,58 - 7,87 760 2,59 10 VA 082 079 7,88 - 8,26 790 2,59 11 VA 086 079 8,27 - 8,64 790 2,59 11 VA 089 084 8,65 - 8,92 840 2,59 11 VA 093 086 8,93 - 9,32 860 2,59 12 VA 096 096 9,33 - 9,66 960 3,07 10 VA 101 096 9,67 - 10,11 960 3,07 11 VA 104 096 10,12 - 10,49 960 3,07 11 VA 107 102 10,50 - 10,79 1020 3,07 12 VA 112 104 10,80 - 11,25 1040 3,45 11 VA 117 107 11,26 - 11,74 1070 3,45 11 VA 122 117 11,75 - 12,25 1170 3,45 12 VA 127 117 12,26 - 12,78 1170 3,71 11 VA 132 119 12,79 - 13,23 1190 3,71 12 VA 138 129 13,24 - 13,83 1290 4,24 11 VA 144 132 13,84 - 14,40 1320 4,24 11 VA 150 155 14,41 - 15,09 1550 4,62 11 VA 157 160 15,10 - 15,70 1600 4,62 11 VA 163 170 15,71 - 16,36 1700 4,62 12 VA 170 175 16,37 - 17,04 1750 5,18 11 VA 177 178 17,05 - 17,78 1780 5,18 11 VA 185 195 17,79 - 18,52 1950 6,35 10 VA 193 201 18,53 - 19,30 2010 6,35 10 VA 201 211 19,31 - 20,12 2110 6,35 11 VA 209 213 20,13 - 20,96 2130 6,35 11 VA 215 218 20,97 - 21,59 2180 6,35 11 VA 225 251 21,60 - 22,50 2510 6,35 12 VA 236 268 22,51 - 23,60 2680 7,87 10 VA 245 274 23,61 - 24,59 2740 7,87 11 VA 254 282 24,60 - 25,42 2820 7,87 11 VA 266 307 25,43 - 26,67 3070 7,87 11 VA 277 322 26,68 - 27,71 3220 7,87 12 VA 288 348 27,72 - 28,86 3480 9,27 11 VA 300 358 28,87 - 30,05 3580 9,27 11 VA 312 363 30,06 - 31,29 3630 9,27 11 VA 339 378 31,30 - 33,99 3780 9,27 12 *) Armor splices consist of single rods with antifriction paste. The paste has to be applicated to the surface of the conductor at installaion location. Stand: 16. April 2010 Pfad: Helical formed fittings/ Line splices/ Line splices (VA) for AAC conductors/ Gedruckt am: 16. Januar 2012 Mass Rods per subset 3-4 3-4 4-4 4-4 4-4 4-4 3-3-3 3-3-3 3-3-3 5-5 3-3-3 3-3-3 5-5 5-5 5-5 3-4-4 5-5 3-4-4 3-4-4 3-4-4 4-4-4 3-3-4 3-4-4 3-4-4 4-4-4 3-4-4 3-4-4 4-4-4 3-4-4 4-4-4 3-4-4 3-4-4 3-4-4 3-4-4 4-4-4 3-4-4 3-4-4 3-3-4 3-3-4 3-4-4 3-4-4 3-4-4 4-4-4 *) kg / 100 pieces 3,6 3,7 4,2 4,5 4,6 4,7 5,6 5,6 5,8 6,7 7,5 7,8 8,7 9,0 9,4 10,3 11,9 13,6 13,6 14,4 16,1 23,1 23,1 23,1 26,7 31,6 32,5 38,8 41,0 45,5 59,0 60,3 84,2 86,9 101,0 119,4 121,5 181,8 187,4 216,3 220,4 223,6 280,7 383,7 431,4 444,0 483,4 553,0 761,0 782,3 793,0 901,0 18 / 53 ONLINE-CATALOGUE Materials: Rods made of aluminium alloy, the inside surface of the rod sets is gritted up to D1 = 22,5 mm. Application: Line splices VA are used as full tension splices for AAC conductors. For ACSR and AACSR conductors they can be usred as non-tension splices. The line splices with rod dia. ≤ 6,35 mm are delivered in premounted rod sets. The contact surface of the rod sets is gritted. All line splices with a rod dia. ≥ 7,87 mm are delivered as single rods. Friction paste has to be applied to the conductor surface before installation. All line splices have a centre marking. Important! The lay direction of the line spices has to equal the lay direction of the outer conductor layer. Mounting instructions: 1) Straighten the conductor ends to be jointed, secure the conductor wires in their proper position and cut the conductor ends so that they have a level surface. 2) Clean the conductor ends over at least the contact length of the line splice. For this purpose we recommend using a steel wire brush, e.g. according to sheet B198/1. 3) Mounting the line splice 3.1) with a rod diameter of ≤ 6,35 mm Place the first set of rods with the colour mark at one conductor end and wrap it on. Position the end of the second conductor at the centre mark of the rod set and wrap it on as well. Wrap on the remaining sets as well, in the same way, starting near the conductor ends. 3.2) with a rod diameter of ≥ 7,87 mm Apply a thin but closed layer of the friction paste on the conductor surface along the contact length of the line splice. The friction paste can be applied by hand or with a paint brush. Place the first rod with the colour mark at one conductor end and wrap it on. Position the end of the second conductor at the centre mark of the rod and wrap it on as well. Wrap on the second rod, in the same way, starting near the conductor ends. The second rod must be placed close to the first one. Proceed with the remaining rods in the same way. 4) Clean the line splice after all rods have been mounted. For this purpose we recommend a steel wire brush, e.g. according to sheet B198/1. Dismantling: Reuse after removal is not allowed. Stand: 16. April 2010 Pfad: Helical formed fittings/ Line splices/ Line splices (VA) for AAC conductors/ Gedruckt am: 16. Januar 2012 19 / 53 ONLINE-CATALOGUE B422/2 Line splices (VK) for copper wires and stranded copper conductors 1 ..... Colored center mark RIBE-Order-No. VK 025 043 VK 026 046 VK 027 046 VK 028 046 VK 029 046 VK 030 051 VK 031 051 VK 032 051 VK 033 051 VK 034 051 VK 036 053 VK 037 056 VK 038 056 VK 039 056 VK 040 056 VK 041 058 VK 042 058 VK 043 063 VK 045 063 VK 046 066 VK 047 066 VK 049 066 VK 050 066 VK 052 068 VK 053 071 VK 055 071 VK 057 076 VK 059 076 VK 061 079 VK 062 081 VK 064 084 VK 066 086 VK 068 089 VK 069 089 VK 071 091 VK 073 094 VK 075 094 VK 077 096 VK 079 096 VK 081 099 VK 084 107 VK 086 109 VK 088 112 Clamping range D1 L Rod dia. Helical rods Number Rods per subset mm 2,46 - 2,54 2,55 - 2,64 2,65 - 2,75 2,76 - 2,84 2,85 - 2,95 2,96 - 3,07 3,08 - 3,18 3,19 - 3,25 3,26 - 3,35 3,36 - 3,48 3,49 - 3,61 3,62 - 3,73 3,74 - 3,81 3,82 - 3,91 3,92 - 4,01 4,02 - 4,19 4,20 - 4,29 4,30 - 4,39 4,40 - 4,55 4,56 - 4,67 4,68 - 4,78 4,79 - 4,93 4,94 - 5,08 5,09 - 5,23 5,24 - 5,38 5,39 - 5,54 5,55 - 5,74 5,75 - 5,97 5,98 - 6,13 6,14 - 6,27 6,28 - 6,47 6,48 - 6,65 6,66 - 6,81 6,82 - 6,98 6,99 - 7,19 7,20 - 7,37 7,38 - 7,57 7,58 - 7,75 7,76 - 7,91 7,92 - 8,15 8,16 - 8,43 8,44 - 8,66 8,67 - 8,87 mm 430 460 460 460 460 510 510 510 510 510 530 560 560 560 560 580 580 630 630 660 660 660 660 680 710 710 760 760 790 810 840 860 890 890 910 940 940 960 960 990 1070 1090 1120 mm 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 1,83 2,06 2,06 2,06 2,06 2,06 2,31 2,31 2,31 2,31 2,31 2,31 2,31 2,31 2,31 2,59 2,59 2,59 6 6 6 6 6 6 7 7 7 7 7 8 8 8 8 8 8 9 9 9 9 9 9 10 9 10 10 10 10 10 11 10 10 10 10 11 11 11 11 11 11 11 11 3-3 3-3 3-3 3-3 3-3 2-2-2 3-4 3-4 3-4 3-4 3-4 4-4 4-4 4-4 4-4 4-4 4-4 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 5-5 5-5 5-5 5-5 5-5 5-5 5-5 3-4-4 5-5 5-5 5-5 5-5 3-4-4 3-4-4 3-4-4 3-4-4 3-4-4 3-4-4 3-4-4 3-4-4 Stand: 08. Mai 2007 Pfad: Helical formed fittings/ Line splices/ Line splices (VK) for copper wires and stranded copper conductors/ Gedruckt am: 16. Januar 2012 Weight kg/ 100 pieces 6,6 7,1 7,1 7,1 7,1 9,1 9,1 9,1 9,1 9,1 9,5 11,4 11,4 11,4 11,4 11,9 11,9 14,5 14,5 15,2 15,2 15,2 15,2 17,4 18,1 18,1 24,6 24,6 25,6 26,2 30,0 35,0 36,2 36,2 37,0 42,1 42,1 43,0 43,0 44,3 60,2 61,3 63,0 20 / 53 ONLINE-CATALOGUE RIBE-Order-No. VK 091112 VK 093 117 VK 096 119 VK 099 122 VK 102 129 VK 105 129 VK 107 132 VK 109 135 VK 111 140 VK 114 142 VK 117 147 VK 121 150 VK 124 152 VK 126 152 VK 130 160 VK 131 162 VK 135 165 VK 137 165 VK 139 165 VK 142 168 VK 146 168 VK 150 175 VK 153 183 VK 158 183 VK 162 190 VK 166 195 VK 170 195 VK 174 203 VK 177 211 VK 181 213 VK 185 218 VK 189 221 VK193 223 VK 196 231 VK 200 239 VK 205 241 VK 209 244 VK 213 249 VK 218 259 VK 221 264 VK 223 269 VK227 274 Clamping range D1 L Rod dia. Helical rods Number Rods per subset Weight mm 8,88 - 9,14 9,15 - 9,32 9,33 - 9,60 9,61 - 9,93 9,94 - 10,26 10,27 - 10,54 10,55 - 10,71 10,72 - 10,97 10,98 - 11,18 11,19 - 11,48 11,49 - 11,76 11,77 - 12,14 12,15 - 12,44 12,45 - 12,62 12,63 - 13,00 13,01 - 13,18 13,19 - 13,51 13,52 - 13,71 13,72 - 13,97 13,98 - 14,27 14,28 - 14,63 14,64 - 15,01 15,02 - 15,37 15,38 - 15,85 15,86 - 16,23 16,24 - 16,64 16,65 - 17,07 17,08 - 17,40 17,41 - 17,78 17,79 - 18,13 18,14 - 18,54 18,55 - 18,92 18,93 - 19,30 19,31 - 19,68 19,69 - 20,06 20,07 - 20,52 20,53 - 20,95 20,96 - 21,38 21,39 - 21,84 21,85 - 22,10 22,11 - 22,35 22,36 - 22,73 mm 1120 1170 1190 1220 1290 1290 1320 1350 1400 1420 1470 1500 1520 1520 1600 1620 1650 1650 1650 1680 1680 1750 1830 1830 1900 1950 1950 2030 2110 2130 2180 2210 2230 2310 2390 2410 2440 2490 2590 2640 2690 2740 mm 2,59 2,89 2,89 2,89 2,89 2,89 2,89 3,66 3,66 3,66 3,66 3,66 3,66 3,66 3,66 3,66 3,66 3,66 3,66 3,66 3,66 3,66 4,11 4,11 4,11 4,11 4,11 4,62 4,62 4,62 4,62 4,62 4,62 4,62 5,18 5,18 5,18 5,18 5,82 5,82 5,82 5,82 11 11 11 11 12 12 12 10 10 10 11 11 11 11 12 12 12 12 12 13 13 13 12 12 13 13 13 12 12 13 13 13 13 14 13 13 13 13 12 12 13 13 3-4-4 3-4-4 3-4-4 3-4-4 4-4-4 4-4-4 4-4-4 3-3-4 3-3-4 3-3-4 3-4-4 3-4-4 3-4-4 3-4-4 4-4-4 4-4-4 4-4-4 4-4-4 4-4-4 4-4-5 4-4-5 4-4-5 4-4-4 4-4-4 4-4-5 4-4-5 4-4-5 4-4-4 4-4-4 4-4-5 4-4-5 4-4-5 4-4-5 4-5-5 3-3-3-4 3-3-3-4 3-3-3-4 3-3-3-4 3-3-3-3 3-3-3-3 3-3-3-4 3-3-3-4 kg/ 100 pieces 63,0 82,0 83,4 85,5 98,6 98,6 101,0 137,8 142,9 144,9 165,1 168,4 171,0 171,0 195,9 198,4 202,0 202,0 202,0 222,8 222,8 232,2 282,5 282,5 317,7 326,2 326,2 396,2 411,8 450,4 461,0 467,3 490,0 526,0 635,0 641,0 649,0 662,0 802,0 818,0 903,0 920,0 Material: Rods: Copper alloy, inside surfaces gritted Application: Line splices VK are used for full tension and current carrying connections between copper conductors (solid or stranded) in the free span. he line splices are centre marked. Attention! The lay direction of the line spices has to be equal the lay direction of the outside cable layer. Mounting instruction: 1) Straighten the ends of the conductor, tie them together and cut them off straight-line. 2) Clean the conductor at both ends at liberally half the length of the line splice. For this purpose we recommend using a wire scratch brush, e.g. according to sheet B198/1. 3) Place the first set of rods with the colour mark at the end of one conductor and coil it up. Place the end of the second conductor on the centre mark of the rod set and coil it up as well. Coil up the remaining sets as well, in the same way, starting near the joint of the conductor’s ends. 4) Clean the line splice. For this purpose we recommend using a wire scratch brush, e.g. according to sheet B198/1. Stand: 08. Mai 2007 Pfad: Helical formed fittings/ Line splices/ Line splices (VK) for copper wires and stranded copper conductors/ Gedruckt am: 16. Januar 2012 21 / 53 ONLINE-CATALOGUE Dismantling: Removal and subsequent reuse of the line splice are not allowed. Stand: 08. Mai 2007 Pfad: Helical formed fittings/ Line splices/ Line splices (VK) for copper wires and stranded copper conductors/ Gedruckt am: 16. Januar 2012 22 / 53 ONLINE-CATALOGUE B422/3 Line splices (VG) for hot dip galvanized steel wires and stranded conductors 1 ..... Colored center mark RIBE-Order-No. VG 026 038 VG 027 038 VG 029 040 VG 030 043 VG 032 046 VG 033 048 VG 035 051 VG 036 053 VG 038 056 VG 040 058 VG 041 061 VG 044 064 VG 046 066 VG 048 069 VG 050 071 VG 052 071 VG 054 074 VG 056 076 VG 059 079 VG 062 084 VG 064 086 VG 067 089 VG 070 091 VG 073 094 VG 076 096 VG 079 099 VG 082 102 VG 085 109 VG 089 112 VG 093 114 VG 096 117 VG 100 119 VG 104 124 VG 108 135 VG 111 137 VG 114 140 VG 117 142 VG 120 147 VG 125 160 VG 130 162 VG 135 165 VG 139 168 VG 145 183 Clamping range D1 L Rod dia. mm 2,54 - 2,64 2,65 - 2,77 2,78 - 2,90 2,91 - 3,05 3,06 - 3,20 3,21 - 3,35 3,36 - 3,50 3,51 - 3,66 3,67 - 3,84 3,85 - 4,01 4,02 - 4,19 4,20 - 4,40 4,41 - 4,60 4,61 - 4,80 4,81 - 5,00 5,01 - 5,23 5,24 - 5,46 5,47 - 5,69 5,70 - 5,94 5,95 - 6,20 6,21 - 6,45 6,46 - 6,73 6,74 - 7,01 7,02 - 7,32 7,33 - 7,62 7,63 - 7,95 7,96 - 8,28 8,29 - 8,58 8,59 - 8,95 8,96 - 9,30 9,31 - 9,68 9,69 - 10,06 10,07 - 10,45 10,46 - 10,80 10,81 - 11,10 11,11 - 11,45 11,46 - 11,75 11,76 - 12,05 12,06 - 12,55 12,56 - 13,05 13,06 - 13,50 13,51 - 13,94 13,95 - 14,53 mm 380 380 400 430 460 480 510 530 560 580 610 640 660 690 710 710 740 760 790 840 860 890 910 940 960 990 1020 1090 1120 1140 1170 1190 1240 1350 1370 1400 1420 1470 1600 1620 1650 1680 1830 mm 1,30 1,30 1,30 1,30 1,30 1,55 1,55 1,55 1,55 1,78 1,78 1,78 2,18 2,18 2,18 1,78 1,78 1,78 1,78 2,18 2,18 2,18 2,18 2,54 2,54 2,54 2,54 3,02 3,02 2,54 2,54 3,02 3,02 3,02 3,02 3,02 3,51 3,51 3,51 3,51 4,04 4,04 4,04 Helical rods No. of rods Stand: 08. Mai 2007 Pfad: Helical formed fittings/ Line splices/ Line splices (VG) for hot dip galvanized steel wires and stranded conductors/ Gedruckt am: 16. Januar 2012 6 8 8 8 8 8 8 8 8 8 8 8 8 8 8 10 10 10 11 10 10 10 11 10 10 10 11 10 10 12 12 11 11 12 12 12 11 11 12 12 11 11 12 Weight Rods per subset 3-3 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 5-5 5-5 5-5 3-4-4 5-5 5-5 5-5 3-4-4 5-5 5-5 5-5 3-4-4 3-3-4 3-3-4 4-4-4 4-4-4 3-4-4 3-4-4 4-4-4 4-4-4 4-4-4 3-4-4 3-4-4 4-4-4 4-4-4 3-4-4 3-4-4 3-3-3-3 kg/ 100 pieces 2,8 3,8 4,0 4,2 4,5 6,6 7,0 7,3 7,7 10,4 11,0 11,5 17,9 18,7 19,2 16,0 16,7 17,1 19,6 28,4 29,1 30,1 33,9 42,5 43,4 44,7 50,7 69,0 71,0 62,0 63,4 82,9 86,4 102,7 104,2 106,4 133,0 137,7 163,5 165,5 206,0 210,0 249,3 23 / 53 ONLINE-CATALOGUE RIBE-Order-No. VG 151 188 VG 157 195 VG 163 201 VG 168 203 VG 190 234 VG 197 239 Clamping range D1 L Rod dia. mm 14,54 - 15,15 15,16 - 15,75 15,76 - 16,36 16,37 - 16,80 18,43 - 19,05 19,06 - 19,71 mm 1880 1950 2010 2030 2340 2390 mm 4,04 4,37 4,04 4,37 4,37 5,18 Helical rods No. of rods 12 12 12 12 13 12 Weight Rods per subset 3-3-3-3 3-3-3-3 3-3-3-3 3-3-3-3 3-3-3-4 3-3-3-4 kg/ 100 pieces 256,1 310,0 319,5 322,7 381,0 515,0 Material: Rods: Steel/ h.d.g. (inside surfaces gritted) Application: Line splices VG are used for full tension and current carrying connections between steel conductors (solid or stranded). For use at suspension points you must ask RIBE. The sets of splices centre marked. Attention! The lay direction of the line spices has to be equal the lay direction of the outside cable layer. Mounting instruction: 1) Straighten the ends of the conductor, tie them together and cut them off straight-line. 2) Clean the conductor at both ends at liberally half the length of the line splice. For this purpose we recommend using a wire scratch brush, e.g. according to sheet B198/1. 3) Place the first set of rods with the colour mark at the end of one conductor and coil it up. Place the end of the second conductor on the centre mark of the rod set and coil it up as well. Coil up the remaining sets as well, in the same way, starting near the joint of the conductor’s ends. 4) Clean the line splice. For this purpose we recommend using a wire scratch brush, e.g. according to sheet B198/1. Dismantling: Removal and subsequent reuse of the line splice are not allowed. Stand: 08. Mai 2007 Pfad: Helical formed fittings/ Line splices/ Line splices (VG) for hot dip galvanized steel wires and stranded conductors/ Gedruckt am: 16. Januar 2012 24 / 53 ONLINE-CATALOGUE B431/1 Insulator ties JA...M for post insulators type "Mittelbund", for AAC, AAAC and ACSR conductors RIBE-Order-No. JA 055 075 M JA 057 075 M JA 060 075 M JA 062 075 M JA 065 080 M JA 068 080 M JA 071 080 M JA 073 080 M JA 075 085 M JA 078 085 M JA 082 085 M JA 086 090 M JA 089 090 M JA 093 095 M JA 096 095 M JA 101 095 M JA 104 095 M JA 107 097 M JA 112 097 M JA 117 097 M JA 122 099 M JA 127 099 M JA 132 099 M JA 138 099 M JA 144 104 M JA 150 104 M JA 159 115 M JA 163 115 M JA 170 120 M JA 177 120 M JA 185 120 M JA 193 130 M JA 201 135 M JA 209 140 M Clamping range D mm 5,39 - 5,56 5,57 - 5,79 5,80 - 6,07 6,08 - 6,25 6,26 - 6,53 6,54 - 6,86 6,87 - 7,11 7,12 - 7,34 7,35 - 7,57 7,58 - 7,87 7,88 - 8,26 8,27 - 8,64 8,65 - 8,92 8,93 - 9,32 9,33 - 9,66 9,67 - 10,11 10,12 - 10,49 10,50 - 10,79 10,80 - 11,25 11,26 - 11,74 11,75 - 12,25 12,26 - 12,78 12,79 - 13,23 13,24 - 13,82 13,83 - 14,40 14,41 - 15,09 15,10 - 15,90 15,91 - 16,36 16,37 - 17,04 17,05 - 17,78 17,79 - 18,52 18,53 - 19,30 19,31 - 20,12 20,13 - 20,96 L mm 750 750 750 750 800 800 800 800 850 850 850 900 900 950 950 950 950 970 970 970 990 990 990 990 1040 1040 1150 1150 1200 1200 1200 1300 1350 1400 S mm 2,18 2,18 2,18 2,18 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 3,07 3,07 3,07 3,07 3,07 3,07 3,07 3,07 4,24 4,24 4,24 4,24 4,24 4,24 4,24 4,24 4,24 4,24 4,24 4,24 4,24 Helical rods Number of subsets Rods per subset Mass 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 4-4 4-4 4-4 4-4 5-5 5-5 5-5 5-5 5-5 5-5 5-5 5-5 5-5 5-5 5-5 5-5 5-5 5-5 5-5 5-5 5-5 5-5 5-5 5-5 5-5 6-4 6-4 6-4 7-4 7-4 7-4 7-5 8-5 8-5 kg/ 100 pieces 6,6 6,6 6,6 6,6 12,5 12,5 12,5 12,5 13,3 13,3 13,3 14,0 14,0 20,7 20,7 20,7 20,7 21,1 21,1 21,1 21,6 41,1 41,1 41,1 43,2 43,2 47,8 47,8 53,9 53,9 53,9 64,8 74,0 74,0 Material: Helical rods: Aluminium alloy Application: Insulator ties JA...M are used to fix AAC, AAAC and ACSR conductors to post insulators type "Mittelbund" resp. "Schrägbund". Stand: 08. Mai 2007 Pfad: Helical formed fittings/ Insulator ties/ Insulator ties JA...M for post insulators type \"Mittelbund\", for AAC, AAAC and ACSR conductors/ Gedruckt am: 16. Januar 2012 25 / 53 ONLINE-CATALOGUE Mounting instruction: See mounting instruction no. 6 Stand: 08. Mai 2007 Pfad: Helical formed fittings/ Insulator ties/ Insulator ties JA...M for post insulators type \"Mittelbund\", for AAC, AAAC and ACSR conductors/ Gedruckt am: 16. Januar 2012 26 / 53 ONLINE-CATALOGUE B431/2 Insulator ties JB...M for post insulators type "Mittelbund", for copper and bronze conductors RIBE-Order-No. JB 052 076 M JB 053 076 M JB 055 076 M JB 057 076 M JB 060 076 M JB 062 076 M JB 065 080 M JB 068 080 M JB 071 080 M JB 073 080 M JB 075 085 M JB 078 085 M JB 082 085 M JB 086 094 M JB 089 094 M JB 093 094 M JB 096 094 M JB 101 097 M JB 104 097 M JB 107 097 M JB 112 102 M JB 117 102 M JB 122 109 M JB 127 109 M JB 132 109 M JB 139 115 M JB 146 115 M JB 163 115 M JB 177 120 M Clamping range D mm 5,09 - 5,23 5,24 - 5,38 5,39 - 5,56 5,57 - 5,79 5,80 - 6,07 6,08 - 6,25 6,26 - 6,53 6,54 - 6,86 6,87 - 7,11 7,12 - 7,34 7,35 - 7,57 7,58 - 7,87 7,88 - 8,26 8,27 - 8,64 8,65 - 8,92 8,93 - 9,32 9,33 - 9,66 9,67 - 10,11 10,12 - 10,49 10,50 - 10,79 10,80 - 11,25 11,26 - 11,74 11,75 - 12,25 12,26 - 12,78 12,79 - 13,23 13,24 - 13,97 13,98 - 14,60 15,30 - 16,30 17,05 - 17,78 L mm 760 760 760 760 760 760 800 800 800 800 850 850 850 940 940 940 940 970 970 970 1020 1020 1090 1090 1090 1150 1150 1150 1200 S mm 1,83 1,83 1,83 1,83 1,83 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,89 2,89 3,25 3,25 3,25 3,25 3,25 3,25 3,25 3,25 3,25 3,25 3,25 4,11 4,11 3,67 4,11 Helical rods Number of subsets Rods per subset Mass 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 5-5 5-5 5-5 5-5 5-5 4-4 4-4 5-5 5-5 5-5 5-5 5-5 5-5 5-5 3-3 3-3 3-3 3-3 3-3 3-3 4-4 4-4 5-5 6-6 6-6 5-5 5-5 6-4 4-5 kg/ 100 pieces 19,4 19,4 19,4 19,4 19,4 31,1 32,7 40,9 40,9 40,9 43,5 43,5 54,2 59,9 45,4 45,4 45,4 46,8 46,8 46,8 65,7 65,7 87,7 105,2 105,2 145,3 145,3 111,0 166,0 Material: Helical rods: Copper alloy Application: Insulator ties JB...M are used to fix copper and copper alloy (bronze) conductors to post insulators type "Mittelbund" resp. "Schrägbund". Mounting instruction: See mounting instruction no. 6 Stand: 08. Mai 2007 Pfad: Helical formed fittings/ Insulator ties/ Insulator ties JB...M for post insulators type \"Mittelbund\", for copper and bronze conductors / Gedruckt am: 16. Januar 2012 27 / 53 ONLINE-CATALOGUE B432/1 Insulator ties JA...L for post insulators type "Längsbund", for AAC, AAAC and ACSR conductors RIBE-Order-No. JA 055 075 L JA 057 075 L JA 060 075 L JA 062 075 L JA 065 080 L JA 068 080 L JA 071 080 L JA 073 080 L JA 075 085 L JA 078 085 L JA 082 085 L JA 086 090 L JA 089 090 L JA 093 095 L JA 096 095 L JA 101 095 L JA 104 095 L JA 107 097 L JA 112 097 L JA 117 097 L JA 122 099 L JA 127 099 L JA 132 099 L JA 138 099 L JA 144 104 L JA 150 104 L Clamping range D mm 5,39 - 5,56 5,57 - 5,79 5,80 - 6,07 6,08 - 6,25 6,26 - 6,53 6,54 - 6,86 6,87 - 7,11 7,12 - 7,34 7,35 - 7,57 7,58 - 7,87 7,88 - 8,26 8,27 - 8,64 8,65 - 8,92 8,93 - 9,32 9,33 - 9,66 9,67 - 10,11 10,12 - 10,49 10,50 - 10,79 10,80 - 11,25 11,26 - 11,74 11,75 - 12,25 12,26 - 12,78 12,79 - 13,23 13,24 - 13,82 13,83 - 14,40 14,41 - 15,09 L mm 750 750 750 750 800 800 800 800 850 850 850 900 900 950 950 950 950 970 970 970 990 990 990 990 1040 1040 S mm 2,18 2,18 2,18 2,18 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 3,07 3,07 3,07 3,07 3,07 3,07 3,07 3,07 4,24 4,24 4,24 4,24 4,24 Helical rods Number of subsets Rods per subset 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 4-4-4 4-4-4 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 Stand: 09. September 2008 Pfad: Helical formed fittings/ Insulator ties/ Insulator ties JA...L for post insulators type \"Längsbund\", for AAC, AAAC and ACSR conductors/ Gedruckt am: 16. Januar 2012 Mass kg/ 100 pieces 7,5 7,5 7,5 7,5 11,2 11,2 11,2 11,2 11,9 11,9 11,9 12,6 12,6 18,7 18,7 18,7 18,7 19,1 19,1 25,4 25,9 37,0 37,0 37,0 38,9 38,9 28 / 53 ONLINE-CATALOGUE JA 157 115 L JA 209 140 L 15,10 - 15,70 20,13 - 20,96 1150 1400 4,24 4,24 3 3 3-3-3 4-4-5 43,0 73,0 Material: Helical rods: Aluminium alloy Application: Insulator ties JA...L are used to fix AAC, AAAC and ACSR conductors to post insulator type "Längsbund". For post insulators of neck type they are -after clearifications with RIBE- suitable in special cases. Mounting instruction: See mounting instruction no. 7 Stand: 09. September 2008 Pfad: Helical formed fittings/ Insulator ties/ Insulator ties JA...L for post insulators type \"Längsbund\", for AAC, AAAC and ACSR conductors/ Gedruckt am: 16. Januar 2012 29 / 53 ONLINE-CATALOGUE B432/2 Insulator ties JB...L for post insulators type "Längsbund", for copper and bronze conductors RIBE-Order-No. JB 052 076 L JB 053 076 L JB 055 076 L JB 057 076 L JB 060 076 L JB 062 076 L JB 065 080 L JB 068 080 L JB 071 080 L JB 073 080 L JB 075 085 L JB 078 085 L JB 082 085 L JB 086 094 L JB 089 094 L JB 093 094 L JB 096 094 L JB 101 097 L JB 104 097 L JB 107 097 L JB 112 102 L JB 117 102 L JB 122 109 L JB 127 109 L JB 132 109 L Clamping range D mm 5,09 - 5,23 5,24 - 5,38 5,39 - 5,56 5,57 - 5,79 5,80 - 6,07 6,08 - 6,25 6,26 - 6,53 6,54 - 6,86 6,87 - 7,11 7,12 - 7,34 7,35 - 7,57 7,58 - 7,87 7,88 - 8,26 8,27 - 8,64 8,65 - 8,92 8,93 - 9,32 9,33 - 9,66 9,67 - 10,11 10,12 - 10,49 10,50 - 10,79 10,80 - 11,25 11,26 - 11,74 11,75 - 12,25 12,26 - 12,78 12,79 - 13,23 L mm 760 760 760 760 760 760 800 800 800 800 850 850 850 940 940 940 940 970 970 970 1020 1020 1090 990 1090 S mm 1,83 1,83 1,83 1,83 1,83 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,89 2,89 3,25 3,25 3,25 3,25 3,25 3,25 3,25 3,25 3,25 3,25 3,25 Helical rods Number of subsets Rods per subset 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 3-3-3 Stand: 09. September 2008 Pfad: Helical formed fittings/ Insulator ties/ Insulator ties JB...L for post insulators type \"Längsbund\", for copper and bronze conductors/ Gedruckt am: 16. Januar 2012 Mass kg/ 100 pieces 17,5 17,5 17,5 17,5 17,5 35,0 36,8 36,8 36,8 36,8 39,1 39,1 48,7 53,9 68,1 68,1 68,1 70,2 70,2 70,2 73,9 73,9 78,9 78,9 78,9 30 / 53 ONLINE-CATALOGUE Material: Helical rods: Copper alloy Application: Insulator ties JB...L are used to fix copper and copper alloy conductors (bronze) to post insulator type "Längsbund". For post insulators of neck type they are -after clearifications with RIBE- suitable in special cases. Mounting instruction: See mounting instruction no. 7 Stand: 09. September 2008 Pfad: Helical formed fittings/ Insulator ties/ Insulator ties JB...L for post insulators type \"Längsbund\", for copper and bronze conductors/ Gedruckt am: 16. Januar 2012 31 / 53 ONLINE-CATALOGUE B433/1 Side ties JW...H for neck type post insulators, for AAC, AAAC and ACSR conductors RIBE-Order-No. JW 050 035 H JW 057 035 H JW 070 042 H JW 070 041 H JW 080 033 H JW 080 037 H JW 080 038 H JW 081 040 H JW 081 041 H JW 080 045 H JW 083 050 H JW 090 041 H JW 090 044 H JW 090 056 H JW 090 053 H JW 093 059 H JW 096 060 H JW 100 060 H JW 103 049 H JW 103 052 H JW 103 047 H JW 103 054 H JW 103 060 H JW 103 061 H JW 116 055 H JW 110 054 H JW 116 061 H JW 132 051 H JW 132 054 H JW 132 059 H JW 132 065 H JW 132 072 H JW 132 083 H JW 132 060 H JW 132 062 H JW 141 053 H JW 149 061 H JW 149 054 H Clamping range D1 Neck dia. D2 L Helical rods S No. of rods mm 4,83 - 5,05 5,53 - 5,76 6,22 - 7,05 6,22 - 7,05 7,06 - 8,01 7,06 - 8,01 7,06 - 8,01 7,06 - 8,01 7,06 - 8,01 7,06 - 8,01 8,02 - 8,30 8,02 - 9,08 8,02 - 9,08 8,02 - 9,08 8,02 - 9,08 8,99 - 9,32 9,33 - 9,67 9,68 - 10,00 9,09 - 10,30 9,09 - 10,30 9,09 - 10,30 9,09 - 10,30 9,09 - 10,30 9,09 - 10,30 10,31 - 11,66 10,31 - 11,66 10,31 - 11,66 11,67 - 13,20 11,67 - 13,20 11,67 - 13,20 11,67 - 13,20 11,67 - 13,20 11,67 - 13,20 11,67 - 13,20 12,52 - 13,26 13,28 - 14,15 13,21 - 14,94 13,21 - 14,94 mm 70 - 74 70 - 74 70 - 74 85 43 50 70 - 74 80 - 81 85 93 50 72 - 75 80 85 88 - 90 43 - 45 80 73 70 82 - 85 93 100 116 120 73 78 85 72 75 80 85 100 116 140 43 - 45 73 62 75 mm 350 350 420 410 330 370 380 450 430 450 485 410 450 560 420 590 600 600 570 580 470 500 600 610 550 540 610 510 540 590 620 720 590 600 620 530 650 540 mm 2,05 2,05 2,30 2,30 2,30 2,30 2,59 2,59 2,59 2,30 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,9 2,9 2,9 2,9 2,9 2,9 2,9 2,9 2,9 2,9 2,9 2,9 2,9 2,9 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Stand: 08. Mai 2007 Pfad: Helical formed fittings/ Insulator ties/ Side ties JW...H for neck type post insulators, for AAC, AAAC and ACSR conductors/ Gedruckt am: 16. Januar 2012 Mass kg/ 100 pieces 4,5 4,5 6,6 6,6 4,9 5,3 7,4 8,6 8,6 7,5 8,2 8,0 8,6 10,3 9,0 10,3 14,1 12,1 12,9 13,0 12,6 13,0 15,2 15,3 16,3 16,0 17,0 15,9 16,1 17,5 18,3 20,5 19,5 22,5 13,9 15,8 16,9 16,1 32 / 53 ONLINE-CATALOGUE RIBE-Order-No. JW 149 057 H JW 149 062 H JW 149 059 H JW 149 075 H JW 149 078 H JW 160 054 H JW 169 063 H JW 169 075 H JW 169 085 H JW 169 077 H JW 175 075 H JW 191 076 H JW 191 087 H JW 218 066 H JW 218 085 H JW 246 083 H Clamping range D1 Neck dia. D2 L Helical rods S No. of rods Mass mm 13,21 - 14,94 13,21 - 14,94 13,21 - 14,94 13,21 - 14,94 13,21 - 14,94 15,12 - 16,02 14,95 - 16,95 14,95 - 16,95 14,95 - 16,95 14,95 - 16,95 15,50 - 17,50 16,96 - 19,18 16,96 - 19,18 19,19 - 21,80 19,19 - 21,80 21,81 - 24,68 mm 80 85 93 100 107 75 85 100 116 140 50 73 95 73 120 82 mm 570 570 590 700 780 540 670 700 770 700 600 760 870 660 850 830 mm 2,9 2,9 2,9 2,9 2,9 2,9 2,9 2,9 2,9 2,9 2,59 3,25 3,25 3,25 3,25 3,25 4 4 4 4 4 4 4 4 4 4 4 4 3 4 3 3 kg/ 100 pieces 16,9 17,0 18,8 20,7 23,3 16,3 19,7 20,5 22,7 22,3 11,5 18,6 21,4 17,9 24,1 21,3 Material: Helical rods: Aluminium-clad steel Application: Side ties type JW...H are used to fix AAC, AAAC and ACSR conductors to the neck groove of medium voltage post insulators (vertical or horizontal position). Mounting instruction: See mounting instruction no. 38e Stand: 08. Mai 2007 Pfad: Helical formed fittings/ Insulator ties/ Side ties JW...H for neck type post insulators, for AAC, AAAC and ACSR conductors/ Gedruckt am: 16. Januar 2012 33 / 53 ONLINE-CATALOGUE B433/2 Side ties JH...H neck type post insulator, for AAC, AAAC, ACSR, copper and bronze conductors RIBE-Order-No. JH 070 042 H JH 077 043 H JH 090 043 H JH 108 056 H JH 116 051 H JH 132 053 H Clamping range D1 Neck dia. D2 L Helical rods S No. of rods Mass mm 6,21 7,04 7,06 8,01 8,02 9,06 9,80 10,80 10,81 11,66 11,67 13,20 mm 73 78 73 78 73 78 73 78 73 78 73 78 mm 390 390 420 560 510 530 mm 2,31 2,31 2,31 2,56 2,56 2,56 3 3 3 4 4 4 kg/ 100 pieces 7,0 7,0 7,4 14,8 14,2 14,4 Material: Helical rods: Stainless steel Application: Side ties type JW...H are used to fix AAC, AAAC and ACSR conductors to the neck groove of medium voltage post insulators (vertical or horizontal position). Mounting instruction: See mounting instruction no. 38e Stand: 22. Juni 2006 Pfad: Helical formed fittings/ Insulator ties/ Side ties JH...H neck type post insulator, for AAC, AAAC, ACSR, copper and bronze conductors/ Gedruckt am: 16. Januar 2012 34 / 53 ONLINE-CATALOGUE B433/3 Side ties JV...H for neck type post insulators, for copper and bronze conductors RIBE-Order-No. JV 080 052 H JV 090 058 H JV 090 065 H JV 093 052 H JV 116 060 H JV 111 061 H JV 132 054 H JV 123 060 H Clamping range D1 Neck dia. D2 L Helical rods S No. of rods Mass mm 7,06 - 8,01 8,02 - 9,08 8,02 - 9,08 8,99 - 9,32 10,31 - 11,66 10,46 - 11,10 12,50 - 13,27 12,50 - 13,27 mm 72 78 92 72 50 35 75 80 mm 520 550 560 520 550 800 540 600 mm 2,59 2,59 2,59 2,59 2,59 2,59 2,89 2,59 3 4 3 4 4 3 4 4 kg/ 100 pieces 11,8 15,6 13,2 14,4 14,7 13,5 19,3 21,1 Material: Helical rods: Copper-clad steel Application: Side ties type JW...H are used to fix AAC, AAAC and ACSR conductors to the neck groove of medium voltage post insulators (vertical or horizontal position). Mounting instruction: See mounting instruction no. 38e Stand: 22. Juni 2006 Pfad: Helical formed fittings/ Insulator ties/ Side ties JV...H for neck type post insulators, for copper and bronze conductors/ Gedruckt am: 16. Januar 2012 35 / 53 ONLINE-CATALOGUE B439/1 Insulator ties JA...Ls for post insulators type StV, for AAC, AAAC and ACSR conductors RIBE-Order-No. JA 080 088 Ls JA 090 089 Ls JA 100 090 Ls JA 110 090 Ls JA 120 100 Ls JA 130 105 Ls JA 140 106 Ls JA 150 125 Ls JA 160 130 Ls JA 170 135 Ls JA 180 140 Ls JA 193 145 Ls JA 200 150 Ls JA 210 150 Ls Clamping range D mm 7,1 - 8,0 8,1 - 9,0 9,1 - 10,0 10,1 - 11,0 11,1 - 12,0 12,1 - 13,0 13,1 - 14,0 14,1 - 15,0 15,1 - 16,0 16,1 - 17,0 17,1 - 18,0 18,1 - 19,0 19,1 - 20,0 20,1 - 21,0 L mm 880 890 900 900 1000 1050 1060 1250 1300 1350 1400 1450 1500 1500 S mm 2,59 3,07 3,07 3,07 3,07 3,70 3,70 3,70 3,70 3,70 3,70 3,70 3,70 3,70 Helical rods Number of subsets Rods per subset Mass 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4-3-3 4-3-3 4-3-3 4-3-3 4-3-3 5-3-3 5-3-3 5-3-3 5-3-3 5-3-3 6-3-3 6-3-3 6-3-3 6-3-3 kg/ 100 pieces 13,1 18,7 19,2 19,2 21,5 36,0 37,0 43,6 45,4 47,1 54,7 56,7 59,0 59,5 Material: Helical rods: Aluminium alloy Application: The ties type JA...Ls are suitable to fix AAC, AAAC and ACSR conductors to post insulators type StV 10, StV 20 and StV 30 according to TGL standard 200-6040. They can be used for horizontal line angles of 180° ± 5°. Stand: 09. September 2008 Pfad: Helical formed fittings/ Insulator ties/ Insulator ties JA...Ls for post insulators type StV, for AAC, AAAC and ACSR conductors/ Gedruckt am: 16. Januar 2012 36 / 53 ONLINE-CATALOGUE B439/2 Insulator ties VA...s/JA...Ls to reinforce AAC, AAAC and ACSR conductors at post insulators StV RIBE-Order-No. Clamping range D mm VA 080 130 s JA 131 110 Ls VA 090 140 s JA 151 119 Ls VA 100 150 s JA 161 128 Ls VA 110 152 s JA 171 132 Ls VA 120 165 s JA 181 145 Ls VA 130 180 s JA 204 160 Ls VA 140 185 s JA 214 165 Ls VA 150 195 s JA 224 175 Ls VA 160 225 s JA 234 205 Ls VA 180 225 s JA 254 205 Ls 7,1 bis 8,0 8,1 bis 9,0 9,1 bis 10,0 10,1 bis 11,0 11,1 bis 12,0 12,1 bis 13,0 13,1 bis 14,0 14,1 bis 15,0 15,1 bis 16,0 17,1 bis 18,0 Helical rods Mass L1 L2 S1 S2 mm 1300 mm mm 2,59 mm 1100 1400 2,59 3,07 1190 1500 3,07 3,07 1280 1520 3,07 3,07 1320 1520 3,07 3,07 1450 1800 3,07 3,70 1600 1850 3,70 3,70 1650 1950 3,70 3,70 1750 2250 3,70 3,70 2050 2250 3,70 3,70 2050 4,24 Stand: 09. September 2008 Pfad: Helical formed fittings/ Insulator ties/ Insulator ties VA...s/JA...Ls to reinforce AAC, AAAC and ACSR conductors at post insulators StV/ Gedruckt am: 16. Januar 2012 Number of subsets Rods per subset kg/ 100 pieces 2 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 4 2 5-5 3-3 3-3-3 3-3 4-3-3 3-3 4-4-4 3-3 4-4-4 3-3 3-4-4 3-3 4-4-4 3-3 5-4-4 3-3 5-5-4 3-3 4-4-4-3 3-3 30,0 42,5 52,3 56,7 58,5 97,6 106,3 113,7 139,3 160,5 37 / 53 ONLINE-CATALOGUE Material: Helical rods: Aluminium alloy Application: The combination of VA...s- and JA...Ls-spirals is suitable for reinforcing damaged AAC, AAAC and ACSR conductors at post insulators type StV 10, StV 20 and StV 30 of TGL-standard 200-6040. The allowed grade of damage is up to breakage of all al-wires of conductor. Stand: 09. September 2008 Pfad: Helical formed fittings/ Insulator ties/ Insulator ties VA...s/JA...Ls to reinforce AAC, AAAC and ACSR conductors at post insulators StV/ Gedruckt am: 16. Januar 2012 38 / 53 ONLINE-CATALOGUE B441/1 Patch rods (RA) for AAC, AAAC, ACSR and AACSR conductors 1 ..... Colored center mark RIBE-Order-No. RA 040 023 RA 042 023 RA 044 023 RA 046 023 RA 049 025 RA 051 030 RA 053 025 RA 055 030 RA 057 028 RA 060 028 RA 062 030 RA 065 030 RA 068 033 RA 071 033 RA 073 033 RA 075 036 RA 078 036 RA 082 036 RA 086 038 RA 089 038 RA 093 041 RA 096 043 RA 101 046 RA 104 046 RA 107 046 RA 112 051 RA 117 051 RA 117 150 s RA 122 053 RA 127 056 RA 132 058 RA 138 061 RA 144 064 RA 150 064 RA 157 066 RA 163 069 RA 170 074 RA 177 076 RA 185 081 RA 193 081 RA 201 089 Clamping range D mm 3,92 - 4,09 4,10 - 4,27 4,28 - 4,47 4,48 - 4,67 4,68 - 4,90 4,91 - 5,13 5,14 - 5,38 5,39 - 5,56 5,57 - 5,79 5,80 - 6,07 6,08 - 6,25 6,26 - 6,53 6,54 - 6,86 6,87 - 7,11 7,12 - 7,34 7,35 - 7,57 7,58 - 7,87 7,88 - 8,26 8,27 - 8,64 8,65 - 8,92 8,93 - 9,32 9,33 - 9,66 9,67 - 10,11 10,12 - 10,49 10,50 - 10,79 10,80 - 11,25 11,26 - 11,74 11,26 - 11,74 11,75 - 12,25 12,26 - 12,78 12,79 - 13,23 13,24 - 13,82 13,83 - 14,40 14,41 - 15,09 15,10 - 15,70 15,71 - 16,36 16,37 - 17,04 17,05 - 17,78 17,79 - 18,52 18,53 - 19,30 19,31 - 20,12 l mm 230 230 230 230 250 300 250 300 280 280 300 300 330 330 330 360 360 360 380 380 410 430 460 460 460 510 510 1500 530 560 580 610 640 640 660 690 740 760 810 810 890 Stand: 31. Mai 2010 Pfad: Helical formed fittings/ Patch rods/ Patch rods (RA) for AAC, AAAC, ACSR and AACSR conductors/ Gedruckt am: 16. Januar 2012 S mm 2,18 2,18 2,18 2,18 2,18 2,18 2,18 2,18 2,18 2,18 2,38 2,38 2,38 2,38 2,38 2,38 2,59 2,59 2,59 2,59 2,59 3,07 3,07 3,07 3,07 3,45 3,45 3,45 3,45 3,71 3,71 4,24 4,24 4,62 4,62 4,62 5,18 5,18 6,35 6,35 6,35 Helical rods No. of rods 7 7 8 8 8 8 9 9 9 10 9 9 10 10 10 11 10 10 11 11 12 11 11 11 12 11 11 11 12 11 12 11 11 11 11 12 11 11 10 10 11 Mass Rods per subset 3-4 3-4 4-4 4-4 4-4 4-4 3-3-3 3-3-3 3-3-3 5-5 3-3-3 3-3-3 5-5 5-5 5-5 3-4-4 5-5 5-5 3-4-4 3-4-4 4-4-4 3-4-4 3-4-4 3-4-4 4-4-4 3-4-4 3-4-4 3-4-4 4-4-4 3-4-4 4-4-4 3-4-4 3-4-4 3-4-4 3-4-4 4-4-4 3-4-4 3-4-4 3-3-4 3-3-4 3-4-4 kg/ 100 pieces 1,8 1,8 2,0 2,0 2,2 2,2 2,5 2,5 2,8 3,1 3,6 3,6 4,4 4,4 4,4 6,2 5,6 6,0 6,5 6,5 7,7 10,4 11,1 11,1 12,1 15,5 15,5 45,0 17,6 19,7 22,2 27,9 29,3 34,8 35,9 40,9 50,5 51,9 73,0 83,1 91,3 39 / 53 ONLINE-CATALOGUE RIBE-Order-No. Clamping range Helical rods D l S No. of rods mm mm mm RA 209 091 20,13 - 20,96 910 6,35 11 RA 215 094 20,97 - 21,59 940 6,35 11 RA 225 099 21,60 - 22,50 990 6,35 12 RA 236 099 22,51 - 23,60 990 7,87 10 RA 245 104 23,61 - 24,59 1040 7,87 11 RA 254 114 24,50 - 25,42 1140 7,87 11 RA 266 114 25,43 - 26,67 1140 7,87 11 RA 277 119 26,68 - 27,71 1190 7,87 12 RA 288 122 27,72 - 28,86 1220 7,87 12 RA 300 127 28,87 - 30,05 1270 7,87 13 RA 312 137 30,06 - 31,29 1370 9,27 11 RA 329 142 31,30 - 32,99 1420 9,27 12 RA 343 147 33,00 - 34,36 1470 9,27 12 RA 358 152 34,37 -35,80 1520 9,27 13 RA 372 165 35,81 - 37,26 1650 9,27 13 RA 388 168 s 37,27 - 38,80 1680 9,27 13 RA 404 173 s 38,81 - 40,40 1730 9,27 14 RA 421 178 s 40,41 - 42,10 1780 9,27 14 RA 438 200 s 42,11 - 43,80 2000 9,27 15 RA 500 212 48,64 - 50,00 2120 9,27 17 RA 517 215 50,10 - 51,70 2150 9,27 17 RA 562 220 54,48 - 56,28 2200 9,27 18 *) Armor splices consist of single rods with antifriction paste. The paste has to be applicated to the surface of the conductor at installation location. Mass Rods per subset 3-4-4 3-4-4 3-3-3-3 *) kg/ 100 pieces 93,3 96,4 110,7 141,7 163,8 179,6 179,6 204,4 209,6 236,4 299,5 338,5 458,1 473,6 514,2 571,2 588,0 605,2 679,0 698,0 709,0 741,0 Material: Helical rods: Aluminium alloy Application: Patch rods are used in the free span to repair conductor damages up to 25% of the outer layer of AAC, AAAC, ACSR and AACSR conductors. They are capable to restore the original mechanical and electrical properties of the conductor. For damages of more then 25% of outer layer line splices type VA and up to total breakage of conductor line splices type VAG can be used. If steel core is undamaged outer splice (al. alloy) of VAG is sufficient, use of filler spirals may be necessary (page B421/1). For damages at suspension clamps use of armor rods SA (page B451/1) or of armor splices SVA (page B454/2) is recommended. Mounting instruction: See mounting instruction no. 39 Stand: 31. Mai 2010 Pfad: Helical formed fittings/ Patch rods/ Patch rods (RA) for AAC, AAAC, ACSR and AACSR conductors/ Gedruckt am: 16. Januar 2012 40 / 53 ONLINE-CATALOGUE B442/1 Patch rods (RG) for stranded steel conductors, h.d.g. 1 ..... Colored center mark RIBE-Orde-No. RG 026 015 RG 027 015 RG 029 018 RG 030 018 RG 032 018 RG 033 018 RG 035 018 RG 036 020 RG 038 020 RG 040 020 RG 041 020 RG 044 023 RG 046 023 RG 048 024 RG 050 024 RG 052 025 RG 054 026 RG 056 028 RG 059 029 RG 062 032 RG 064 032 RG 067 032 RG 070 035 RG 073 035 RG 076 036 RG 079 036 RG 082 036 RG 085 037 RG 089 038 RG 093 039 RG 096 040 RG 100 042 RG 104 044 RG 108 046 RG 111 048 RG 114 050 RG 117 051 RG 120 052 RG 125 054 RG 130 056 RG 135 058 RG 139 058 Clamping range D mm 2,54 - 2,64 2,65 - 2,77 2,78 - 2,90 2,91 - 3,05 3,06 - 3,20 3,21 - 3,35 3,36 - 3,50 3,51 - 3,66 3,67 - 3,84 3,85 - 4,01 4,02 - 4,19 4,20 - 4,40 4,41 - 4,60 4,61 - 4,80 4,81 - 5,00 5,01 - 5,23 5,24 - 5,46 5,47 - 5,69 5,70 - 5,94 5,95 - 6,20 6,21 - 6,45 6,46 - 6,73 6,74 - 7,01 7,02 - 7,32 7,33 - 7,62 7,63 - 7,95 7,96 - 8,28 8,29 - 8,58 8,59 - 8,95 8,96 - 9,30 9,31 - 9,68 9,69 - 10,06 10,07 - 10,45 10,46 - 10,80 10,81 - 11,10 11,11 - 11,45 11,46 - 11,75 11,76 - 12,05 12,06 - 12,55 12,56 - 13,05 13,06 - 13,50 13,51 - 13,94 L mm 150 150 180 180 180 180 180 200 200 200 200 230 230 240 240 250 260 280 290 320 320 320 350 350 360 360 360 370 380 390 400 420 440 460 480 500 510 520 540 560 580 580 Stand: 11. Mai 2007 Pfad: Helical formed fittings/ Patch rods/ Patch rods (RG) for stranded steel conductors, h.d.g./ Gedruckt am: 16. Januar 2012 S mm 1,30 1,30 1,30 1,30 1,30 1,55 1,55 1,55 1,55 1,78 1,78 1,78 2,18 2,18 2,18 1,78 1,78 1,78 1,78 2,18 2,18 2,18 2,18 2,54 2,54 2,54 2,54 3,02 3,02 2,54 2,54 3,02 3,02 3,02 3,02 3,02 3,51 3,51 3,51 3,51 4,04 4,04 Helical rods No. of rods 6 8 8 8 8 8 8 8 8 8 8 8 8 8 8 10 10 10 11 10 10 10 11 10 10 10 11 10 10 12 12 11 11 12 12 12 11 11 12 12 11 11 Mass Rods per subset 3-3 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 4-4 5-5 5-5 5-5 3-4-4 5-5 5-5 5-5 3-4-4 5-5 5-5 5-5 3-4-4 3-3-4 3-3-4 4-4-4 4-4-4 3-4-4 3-4-4 4-4-4 4-4-4 4-4-4 3-4-4 3-4-4 4-4-4 4-4-4 3-4-4 3-4-4 kg/ 100 pieces 1,1 1,5 1,8 1,8 1,8 2,5 2,5 2,8 2,8 3,6 3,6 4,1 6,2 6,5 6,5 5,6 5,8 6,3 7,2 10,9 10,9 10,9 13,1 15,9 16,3 16,3 17,9 23,5 24,2 21,2 21,7 29,3 30,7 35,0 36,6 38,0 47,8 48,8 55,2 57,3 72,5 72,5 41 / 53 ONLINE-CATALOGUE RIBE-Orde-No. RG 145 060 RG 151 062 RG 157 065 RG 163 067 RG 168 068 RG 178 072 RG 190 078 Clamping range D mm 13,95 - 14,53 14,54 - 15,15 15,16 - 15,75 15,76 - 16,36 16,37 - 16,80 17,31 - 17,85 18,43 - 19,05 L mm 600 620 650 670 680 720 780 S mm 4,04 4,04 4,37 4,37 4,37 4,37 4,37 Helical rods No. of rods 12 12 12 12 12 13 13 Mass Rods per subset 3-3-3-3 3-3-3-3 3-3-3-3 3-3-3-3 3-3-3-3 3-3-3-4 3-3-3-4 kg/ 100 pieces 81,7 84,5 103,4 106,6 108,2 118,0 128,0 Material: Helical rods: Steel, h.d.g. Application: Patch rods are used in the free span to repair damages up to 25% of the outer layer of steel conductors hot dip galvanized. They are capable to restore the original mechanical and electrical properties of the conductor. For damages of more than 25% of the outer layer line splices VG (see page B422/3) can be used. For damages at suspension clamps use of armor rods SG (page B454/1) to recommended. Mounting instruction: See mountimng instruction no. 39 Stand: 11. Mai 2007 Pfad: Helical formed fittings/ Patch rods/ Patch rods (RG) for stranded steel conductors, h.d.g./ Gedruckt am: 16. Januar 2012 42 / 53 ONLINE-CATALOGUE B443/1 Patch rods (RK) for copper and copper alloy conductors 1 ..... Colored center mark RIBE-Order-No. RK 041 020 RK 042 023 RK 045 023 RK 050 023 RK 052 025 RK 055 025 RK 057 025 RK 061 028 RK 062 028 RK 064 030 RK 066 030 RK 068 030 RK 069 033 RK 071 033 RK 073 033 RK 075 033 RK 077 036 RK 079 036 RK 081 036 RK 084 038 RK 086 038 RK 088 041 RK 091 041 RK 093 041 RK 096 043 RK 099 043 RK 102 046 RK 105 046 RK 107 048 RK 109 048 RK 111 050 RK 114 050 RK 117 053 RK 121 053 RK 124 053 RK 126 056 RK 130 058 RK 131 058 RK 135 058 RK 137 058 RK 139 058 RK 142 061 Clamping range D mm 4,02 - 4,19 4,20 - 4,29 4,40 - 4,55 4,94 - 5,08 5,09 - 5,23 5,39 - 5,54 5,55 - 5,74 5,98 - 6,13 6,14 - 6,27 6,28 - 6,47 6,48 - 6,65 6,66 - 6,81 6,82 - 6,98 6,99 - 7,19 7,20 - 7,37 7,38 - 7,57 7,58 - 7,75 7,76 - 7,91 7,92 - 8,15 8,16 - 8,43 8,44 - 8,66 8,67 - 8,87 8,88 - 9,14 9,15 - 9,32 9,33 - 9,60 9,61 - 9,93 9,94 - 10,26 10,27 - 10,54 10,55 - 10,71 10,72 - 10,97 10,98 - 11,18 11,19 - 11,48 11,49 - 11,76 11,77 - 12,14 12,15 - 12,44 12,45 - 12,62 12,63 - 13,00 13,01 - 13,18 13,19 - 13,51 13,52 - 13,71 13,72 - 13,97 13,98 - 14,27 L mm 200 230 230 230 250 250 250 280 280 300 300 300 330 330 330 330 360 360 360 380 380 410 410 410 430 430 460 460 480 480 500 500 530 530 530 560 580 580 580 580 580 610 Stand: 11. Mai 2007 Pfad: Helical formed fittings/ Patch rods/ Patch rods (RK) for copper and copper alloy conductors/ Gedruckt am: 16. Januar 2012 S mm 1,83 1,83 1,83 1,83 1,83 1,83 2,06 2,06 2,06 2,06 2,31 2,31 2,31 2,31 2,31 2,31 2,31 2,31 2,31 2,59 2,59 2,59 2,59 2,89 2,89 2,89 2,89 2,59 2,89 3,66 3,66 3,66 3,66 3,66 3,66 3,66 3,66 3,66 3,66 3,66 3,66 3,66 Helical rods No. of rods 8 8 9 9 10 10 10 10 10 11 10 10 10 10 11 11 11 11 11 11 11 11 11 11 11 11 12 13 12 10 10 10 11 11 11 11 12 12 12 12 12 13 Mass Rods per subset 4-4 4-4 3-3-3 3-3-3 5-5 5-5 5-5 5-5 5-5 3-4-4 5-5 5-5 5-5 5-5 3-4-4 3-4-4 3-4-4 3-4-4 3-4-4 3-4-4 3-4-4 3-4-4 3-4-4 3-4-4 3-4-4 3-4-4 4-4-4 4-4-5 4-4-4 3-3-4 3-3-4 3-3-4 3-4-4 3-4-4 3-4-4 3-4-4 4-4-4 4-4-4 4-4-4 4-4-4 4-4-4 4-4-5 kg/ 100 pieces 4,0 4,6 5,2 5,2 6,3 6,3 8,1 9,1 9,1 10,7 12,2 12,2 13,5 13,5 14,8 14,8 16,2 16,2 16,2 21,4 21,4 23,1 23,1 28,8 30,2 30,2 35,2 30,0 36,8 49,1 51,1 51,1 59,6 59,6 59,6 62,9 71,1 71,1 71,1 71,1 71,1 81,0 43 / 53 ONLINE-CATALOGUE RIBE-Order-No. Clamping range Helical rods D L S No. of rods mm mm mm RK 146 061 14,28 - 14,63 610 3,66 13 RK 150 063 14,64 - 15,01 630 3,66 13 RK 153 066 15,02 - 15,37 660 4,11 12 RK 158 066 15,38 - 15,85 660 4,11 12 RK 162 068 15,86 - 16,23 680 4,11 13 RK 166 068 16,24 - 16,64 680 4,11 13 RK 170 071 16,65 - 17,07 710 4,11 13 RK 174 073 17,08 - 17,40 730 4,62 12 RK 177 076 17,41 - 17,78 760 4,62 12 RK 181 076 17,79 - 18,13 760 4,62 13 RK 185 079 18,14 - 18,54 790 4,62 13 RK 189 079 18,55 - 18,92 790 4,62 13 RK 193 081 18,93 - 19,30 810 4,62 13 RK 196 084 19,31 - 19,68 840 4,62 14 RK 200 086 19,69 - 20,06 860 5,18 13 RK 205 086 20,07 - 20,52 860 5,18 13 RK 209 086 20,53 - 20,95 860 5,18 13 RK 213 090 20,96 - 21,38 900 5,18 13 RK 218 094 21,39 - 21,84 940 5,82 12 RK 221 094 21,85 - 22,10 940 5,82 12 RK 223 096 22,11 - 22,35 960 5,82 13 RK 227 099 22,36 - 22,73 990 5,82 13 RK 231 099 22,74 - 23,16 990 5,82 13 RK 236 101 23,17 - 23,62 1010 5,82 13 RK 240 101 23,63 - 24,08 1010 5,82 13 RK 245 104 24,09 - 24,58 1040 6,55 12 RK 251 104 24,59 - 25,14 1040 6,55 12 RK 256 109 25,15 - 26,65 1090 6,55 13 RK 262 112 25,66 - 26,21 1120 6,55 13 RK 267 114 26,22 - 26,79 1140 7,34 12 RK 273 117 26,80 - 27,33 1170 7,34 12 RK 279 117 27,34 - 27,94 1170 7,34 12 RK 283 122 27,95 - 28,35 1220 7,34 13 RK 287 122 28,36 - 28,75 1220 7,34 13 RK 293 124 28,76 - 29,31 1240 7,34 13 RK 298 124 29,32 - 29,84 1240 7,34 13 RK 304 129 29,85 - 30,48 1290 8,25 12 *) Armor splices consist of single rods with antifriction paste. The paste has to be applicated to the surface of the conductor at installation location. Mass Rods per subset 4-4-5 4-4-5 4-4-4 4-4-4 4-4-5 4-4-5 4-4-5 4-4-4 4-4-4 4-4-5 4-4-5 4-4-5 4-4-5 4-5-5 3-3-3-4 3-3-3-4 3-3-3-4 3-3-3-4 3-3-3-3 3-3-3-3 3-3-3-4 3-3-3-4 3-3-3-4 3-3-3-4 3-3-3-4 3-3-3-3 3-3-3-3 3-3-3-4 3-3-3-4 *) kg/ 100 pieces 81,0 83,6 102,0 102,0 113,9 113,9 118,8 142,6 148,5 160,8 167,2 167,2 171,4 191,4 228,7 228,7 228,7 239,2 291,2 291,2 322,2 332,4 332,4 338,8 338,8 408,0 408,0 463,4 475,9 561,5 576,4 576,4 650,8 650,8 661,6 661,6 669,2 Material: Helical rods: Copper alloy Application: Patch rods are used in the free span to repair damages of the outer layer up to 25%. They are capable to restore the original electrical and mechanical properties of the conductor. For damages of more than 25% of the outer layer line splices VK (see page B422/2) can be used. For damanges at suspensions clamps use of armor rods SB (page B453/1) is recommended. Mounting instruction: See mounting instruction no. 39 Stand: 11. Mai 2007 Pfad: Helical formed fittings/ Patch rods/ Patch rods (RK) for copper and copper alloy conductors/ Gedruckt am: 16. Januar 2012 44 / 53 ONLINE-CATALOGUE B451/1 Armor rods (SA) for AAC, AAAC, ACSR and AACSR conductors 1 ..... Colored center mark RIBE-Order-No. SA 051 102 SA 052 102 SA 053 102 SA 055 102 SA 057 102 SA 058 102 SA 059 102 SA 061 102 SA 063 102 SA 065 102 SA 067 102 SA 068 102 SA 069 102 SA 071 102 SA 073 102 SA 075 102 SA 077 107 SA 080 107 SA 082 112 SA 084 112 SA 086 117 SA 088 122 SA 090 122 SA 093 122 SA 098 127 SA 105 132 SA 111 137 SA 119 137 SA 126 142 SA 131 142 SA 136 142 SA 143 152 SA 149 163 SA 158 163 SA 166 163 SA 175 173 SA 179 173 SA 186 183 SA 195 183 SA 203 139 SA 212 193 SA 224 198 Clamping range D1 Outer diameter D2 L Helical rods Rod dia. No. of rods 4,99 - 5,10 5,11 - 5,23 5,24 - 5,38 5,39 - 5,54 5,55 - 5,76 5,77 - 5,82 5,83 - 5,97 5,98 - 6,15 6,16 - 6,32 6,33 - 6,53 6,54 - 6,70 6,71 - 6,86 6,87 - 6,98 6,99 - 7,16 7,17 - 7,37 7,38 - 7,57 7,58 - 7,75 7,76 - 8,00 8,01 - 8,25 8,26 - 8,43 8,44 - 8,64 8,65 - 8,81 8,82 - 9,07 9,08 - 9,35 9,36 - 9,86 9,87 - 10,54 10,55 - 11,18 11,19 - 11,94 11,95 - 12,65 12,66 - 13,16 13,17 - 13,64 13,65 - 14,35 14,36 - 14,91 14,92 - 15,88 15,89 - 16,66 16,67 - 17,50 17,51 - 17,93 17,94 - 18,64 18,65 - 19,53 19,51 - 20,32 20,33 - 21,21 21,22 - 22,45 11,2 11,4 11,5 11,7 11,9 12,0 12,1 13,6 13,7 14,0 14,1 14,3 14,4 14,6 14,8 15,0 15,2 15,4 15,7 15,9 16,1 16,2 16,5 16,8 18,3 19,0 19,7 20,4 21,1 21,6 22,1 23,6 24,3 25,1 25,9 26,7 28,2 29,0 29,9 33,0 33,9 35,2 mm 1020 1020 1020 1020 1020 1020 1020 1020 1020 1020 1020 1020 1020 1020 1020 1020 1070 1070 1120 1120 1170 1220 1220 1220 1270 1320 1370 1370 1420 1420 1420 1520 1630 1630 1630 1730 1730 1830 1830 1930 1930 1980 mm 3,07 3,07 3,07 3,07 3,07 3,07 3,07 3,71 3,71 3,71 3,71 3,71 3,71 3,71 3,71 3,71 3,71 3,71 3,71 3,71 3,71 3,71 3,71 3,71 4,24 4,24 4,24 4,24 4,24 4,24 4,24 4,62 4,62 4,62 4,62 4,62 5,18 5,18 5,18 6,35 6,35 6,35 7 7 7 7 8 8 8 7 7 7 7 7 8 8 8 8 8 8 8 9 9 9 9 9 9 9 9 9 10 11 11 11 11 11 12 12 12 12 13 11 11 12 Stand: 11. Mai 2007 Pfad: Helical formed fittings/Armor rods/ Armor rods (SA) for AAC, AAAC, ACSR and AACSR conductors/ Gedruckt am: 16. Januar 2012 Weight kg/ 100 pieces 15,6 15,6 15,6 15,6 15,6 17,8 17,8 22,8 22,8 22,8 22,8 22,8 26,0 26,0 26,0 26,0 27,2 27,2 28,5 32,1 33,5 35,0 35,0 35,0 47,5 49,4 56,9 56,9 59,0 64,9 64,9 82,6 88,6 88,6 96,6 102,6 128,8 136,2 147,6 197,9 197,9 221,4 45 / 53 ONLINE-CATALOGUE RIBE-Order-No. SA 235 203 SA 249 213 SA 262 234 SA 276 244 SA 289 254 SA 304 254 SA 321 254 SA 337 254 SA 354 254 SA 372 254 SA 388 254 SA 401 254 SA 517 274 Clamping range D1 Outer diameter D2 L Helical rods Rod dia. No. of rods Weight 22,46 - 23,57 23,58 - 24,97 24,98 - 26,26 26,27 - 27,69 27,70 - 28,96 28,97 - 30,43 30,44 - 32,13 32,14 - 33,78 33,79 - 35,46 35,47 - 37,21 37,22 - 38,86 38,87 - 40,13 49,70 - 51,70 36,3 37,7 42,0 43,4 44,7 46,2 50,7 52,3 54,0 55,8 57,4 58,7 70,2 mm 2030 2130 2340 2440 2540 2540 2540 2540 2540 2540 2540 2540 2740 mm 6,35 6,35 7,87 7,87 7,87 7,87 9,27 9,27 9,27 9,27 9,27 9,27 9,27 12 13 11 12 12 13 12 12 13 13 13 14 17 kg/ 100 pieces 227,1 258,1 368,5 419,1 436,3 472,6 605,4 605,4 655,9 642,4 641,6 691,5 901,0 Material: Helical rods: Aluminium alloy Application: Use of armor rods SA reduces bending stress at clamping points (f.e. suspension clamps) at AAC, AAAC, ACSR and AACSR conductors. They have no damping properties. Armor rods can be used as patch rods up to damages of 25% of the outer layer at suspension points. By this they protect the conductor against damages by arcing foot points, too. Mounting instruction: See instruction-no. 48 Stand: 11. Mai 2007 Pfad: Helical formed fittings/Armor rods/ Armor rods (SA) for AAC, AAAC, ACSR and AACSR conductors/ Gedruckt am: 16. Januar 2012 46 / 53 ONLINE-CATALOGUE B453/1 Armor rods (SB) for copper and bronze conductors 1 ..... Colored center mark RIBE-Order-No. SB 041 102 SB 042 102 SB 043 102 SB 045 102 SB 046 102 SB 047 102 SB 049 102 SB 050 102 SB 052 102 SB 053 102 SB 055 102 SB 057 102 SB 059 102 SB 061 102 SB 062 102 SB 064 102 SB 066 107 SB 068 107 SB 069 107 SB 071 107 SB 073 107 SB 075 107 SB 077 117 SB 079 117 SB 081 117 SB 084 117 SB 086 122 SB 088 127 SB 091 127 SB 093 132 SB 096 132 SB 098 137 SB 102 142 SB 107 142 SB 111 142 SB 116 142 SB 123 142 SB 130 142 SB 135 147 SB 139 152 SB 146 152 SB 152 152 Clamping range D1 Outer diameter D2 L mm 4,02 - 4,19 4,20 - 4,29 4,30 - 4,39 4,40 - 4,55 4,56 - 4,67 4,68 - 4,78 4,79 - 4,93 4,94 - 5,08 5,09 - 5,23 5,24 - 5,38 5,39 - 5,54 5,55 - 5,74 5,75 - 5,97 5,98 - 6,13 6,14 - 6,27 6,28 - 6,47 6,48 - 6,65 6,66 - 6,81 6,82 - 6,98 6,99 - 7,19 7,20 - 7,37 7,38 - 7,57 7,58 - 7,75 7,76 - 7,91 7,92 - 8,15 8,16 - 8,43 8,44 - 8,66 8,67 - 8,87 8,88 - 9,14 9,15 - 9,32 9,33 - 9,60 9,61 - 9,85 9,86 - 10,29 10,30 - 10,71 10,72 - 11,10 11,11 - 11,63 11,64 - 12,35 12,36 - 13,00 13,01 - 13,51 13,52 - 13,97 13,98 - 14,60 14,61 - 15,27 mm 9,4 9,5 9,6 9,7 9,9 10,0 10,1 10,3 10,4 10,6 10,7 10,9 11,2 11,3 11,5 11,7 11,8 12,0 12,2 12,4 12,6 13,4 13,5 13,7 14,7 14,9 15,2 15,4 15,6 15,8 16,1 16,4 17,6 18,0 19,3 19,9 20,6 21,2 21,7 22,2 22,8 23,5 mm 1020 1020 1020 1020 1020 1020 1020 1020 1020 1020 1020 1020 1020 1020 1020 1020 1070 1070 1070 1070 1070 1070 1170 1170 1170 1170 1220 1270 1270 1320 1320 1370 1420 1420 1420 1420 1420 1420 1470 1520 1520 1520 Stand: 11. Mai 2007 Pfad: Helical formed fittings/Armor rods/ Armor rods (SB) for copper and bronze conductors/ Gedruckt am: 16. Januar 2012 Helical rods Rod dia. mm 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,59 2,89 2,89 2,89 3,25 3,25 3,25 3,25 3,25 3,25 3,25 3,25 3,66 3,66 4,11 4,11 4,11 4,11 4,11 4,11 4,11 4,11 Weight No. of rods 7 7 7 7 7 7 7 7 8 8 8 8 9 9 9 9 9 10 10 10 10 10 9 10 9 9 10 10 10 10 10 11 10 10 10 10 10 11 11 12 12 12 kg/ 100 pieces 36,5 36,5 36,5 36,5 36,5 36,5 36,5 36,5 41,8 41,8 41,8 41,8 47,0 47,0 47,0 47,0 49,2 54,7 54,7 54,7 54,7 68,1 74,5 74,5 84,7 84,7 98,2 102,2 102,2 106,2 106,2 121,3 144,9 144,9 182,7 182,7 182,7 201,0 227,0 234,7 234,7 234,7 47 / 53 ONLINE-CATALOGUE RIBE-Order-No. SB 160 152 SB 167 152 SB 176 162 SB 184 162 SB 191 168 SB 199 168 SB 207 173 SB 214 173 SB 222 178 SB 231 178 Clamping range D1 Outer diameter D2 L mm 15,28 - 16,00 16,01 - 16,77 16,78 - 17,62 17,63 - 18,49 18,50 - 19,18 19,19 - 19,94 19,95 - 20,70 20,71 - 21,46 21,47 - 22,25 22,26 - 23,11 mm 25,2 26,0 26,8 27,7 28,4 29,2 29,9 31,5 32,6 33,5 mm 1520 1520 1620 1620 1680 1680 1730 1730 1780 1780 Helical rods Rod dia. mm 4,62 4,62 4,62 4,62 4,62 4,62 4,62 5,18 5,18 5,18 Weight No. of rods 12 12 13 13 14 14 15 13 14 15 kg/ 100 pieces 296,7 296,7 342,6 342,6 382,5 382,5 422,1 459,7 509,3 545,6 Material: Helical rods: Copper alloy Application: Use of armor rods SB reduces bending stress at clamping points (f.e. suspension clamps) at copper and bronze (copper alloy) conductors. Armor rods don’t have damping properties. Armor rods can be used as patch rods up to damages of 25% of the outer layer at suspension points. By this they protect the conductor against damages by arcing foot points, too. Mounting instruction: See instruction-no. 48 Stand: 11. Mai 2007 Pfad: Helical formed fittings/Armor rods/ Armor rods (SB) for copper and bronze conductors/ Gedruckt am: 16. Januar 2012 48 / 53 ONLINE-CATALOGUE B454/1 Armor splices (SVA) for AAC, AAAC and ACSR conductors 1 ..... Colored center mark RIBE-Order-No. Clamping range Outer diameter Helical rods D1 D2 L Rod dia. No. of rods mm mm mm mm SVA 082 112 8,01 - 8,25 15,7 1120 3,71 8 SVA 098 127 9,36 - 9,86 18,3 1270 4,24 9 SVA 105 132 9,87 - 10,54 19,0 1320 4,24 9 SVA 111 137 10,55 - 11,18 19,7 1370 4,24 9 SVA 119 137 11,19 - 11,94 20,4 1370 4,24 10 SVA 126 142 11,95 - 12,65 21,1 1420 4,24 10 SVA 131 142 12,66 - 13,16 21,6 1420 4,24 11 SVA 136 142 13,17 - 13,64 22,1 1420 4,24 11 SVA 143 152 13,65 - 14,35 23,6 1520 4,62 11 SVA 149 163 14,36 - 14,91 24,3 1630 4,62 11 SVA 158 163 14,92 - 15,88 25,1 1630 4,62 12 SVA 166 170 15,89 - 16,66 25,9 1700 4,62 12 SVA 175 175 16,67 - 17,50 26,7 1750 4,62 12 SVA 179 195 17,51 - 17,93 28,2 1950 5,18 12 SVA 186 195 17,94 - 18,64 29,0 1950 5,18 12 SVA 195 201 18,65 - 19,53 29,9 2010 5,18 13 SVA 203 211 19,54 - 20,32 33,0 2110 6,35 11 SVA 212 213 20,33 - 21,21 33,9 2130 6,35 11 SVA 224 218 21,22 - 22,45 35,2 2180 6,35 12 SVA 235 268 22,46 - 23,57 36,3 2680 6,35 12 SVA 249 274 23,58 - 24,97 37,7 2740 6,35 13 SVA 262 282 24,98 - 26,26 42,0 2820 7,87 11 SVA 276 322 26,27 - 27,69 43,4 3220 7,87 12 SVA 289 348 27,70 - 28,96 44,7 3480 7,87 12 SVA 304 358 28,97 - 30,43 46,2 3580 7,87 13 SVA 321 363 30,44 - 32,13 50,7 3630 9,27 11 SVA 337 378 32,14 - 33,78 52,3 3780 9,27 12 SVA 354 386 33,79 - 35,46 54,0 3800 9,27 13 *) Armor splices consits of single rods with antifriction paste. The paste has to be applicated to the surface of the conductor at installation location. Weight Rods per subset 4-4 3-3-3 3-3-3 3-3-3 3-3-4 3-3-4 3-4-4 3-4-4 3-4-4 3-4-4 4-4-4 4-4-4 4-4-4 4-4-4 4-4-4 3-3-3-4 3-4-4 3-4-4 3-3-3-3 3-3-3-3 3-3-3-4 *) kg/ 100 pieces 28,0 47,5 49,4 47,0 56,9 59,0 64,9 64,9 82,6 88,6 96,6 101,0 101,1 142,0 137,0 148,0 216,0 220,0 223,0 280,0 302,5 444,0 55,35 587,3 610,5 793,3 901,0 940,0 Material: Helical rods: Aluminium alloy (subsets sanded up to dia. 24,97 mm) Application: Armor splices SVA are used at suspension points if • at AAC or AAAC (see remark) conductors more than 25% of the outer layer and up to 100% of all wires • at ACSR conductors up to 100% of al. wires, with undamaged steel core are damaged or destroyed. Armor splices SVA restore the original mechanical and electrical properties of the conductor. Assembly to be performed following mounting instruction no.14e in principle. Mounting instruction: See instruction no. 14 Remark: For applying at AACSR please contact the factory. Stand: 11. Mai 2007 Pfad: Helical formed fittings/Armor rods/ Armor splices (SVA) for AAC, AAAC and ACSR conductors/ Gedruckt am: 16. Januar 2012 49 / 53 ONLINE-CATALOGUE B454/2 Armor rods (SG) for stranded steel conductors, h.d.g. 1 ..... Colored center mark RIBE-Order-No. SG 043 058 SG 046 061 SG 049 064 SG 052 066 SG 055 068 SG 057 071 SG 061 074 SG 065 076 SG 069 079 SG 073 081 SG 078 084 SG 082 085 SG 087 089 SG 094 091 SG 098 094 SG 105 096 SG 110 099 SG 117 102 SG 124 104 SG 132 107 SG 139 109 SG 148 112 Clamping range D1 Outer diameter D2 L Helical rods Rod dia. No. of rods Weight mm 4,08 - 4,35 4,36 - 4,60 4,61 - 4,90 4,91 - 5,26 5,27 - 5,59 5,60 - 5,79 5,80 - 6,17 6,18 - 6,58 6,59 - 6,94 6,95 - 7,35 7,36 - 7,83 7,84 - 8,28 8,29 - 8,79 8,80 - 9,48 9,49 - 9,88 9,89 - 10,50 10,51 - 11,08 11,09 - 11,77 11,78 - 12,45 12,46 - 13,24 13,25 - 13,99 14,00 - 14,86 mm 7,9 9,0 9,3 9,6 10,0 10,2 10,5 10,9 12,0 12,4 12,9 13,4 13,9 14,6 15,9 16,5 17,1 18,8 19,5 20,3 22,1 22,9 mm 580 610 640 660 680 710 740 760 790 810 840 850 890 910 940 960 990 1020 1040 1070 1090 1120 mm 1,78 2,18 2,18 2,18 2,18 2,18 2,18 2,18 2,54 2,54 2,54 2,54 2,54 2,54 3,02 3,02 3,02 3,51 3,51 3,51 4,04 4,04 9 8 8 8 9 9 10 10 9 10 10 11 11 11 11 11 12 11 12 12 11 12 kg/ 100 pieces 11,8 16,5 17,3 17,9 20,7 21,6 25,0 25,7 32,1 36,6 38,0 42,3 44,2 45,2 65,5 67,0 75,3 95,6 106,3 118,5 136,1 152,6 Material: Helical rods: Steel/ h.d.g. Application: Use of armor rods SG reduces bending stress at clamping points (f.e. suspension clamps) at steel conductors, hot dip galvanized. They have no damping properties. Armor rods can be used as patch rods up to damages of 25% of the outer layer at suspension points. By this they protect the conductor against damages by arcing foot points, too. Mounting instruction: See instruction-no. 48 Stand: 11. Mai 2007 Pfad: Helical formed fittings/Armor rods/ Armor rods (SG) for stranded steel conductors, h.d.g./ Gedruckt am: 16. Januar 2012 50 / 53 ONLINE-CATALOGUE B462/1 Spacers (BP) for all types of conductors RIBE-Order-No. BP 044 040 BP 063 015 BP 063 050 BP 082 050 BP 117 050 BP 117 060 BP 117 080 BP 136 010 BP 136 050 BP 136 070 Clamping range D mm 3,42 - 4,40 4,41 - 6,33 4,41 - 6,33 6,34 - 8,28 8,29 - 11,70 8,29 - 11,70 8,29 - 11,70 11,71 - 13,60 11,71 - 13,60 11,71 - 13,60 Mass L mm 200 220 200 260 300 300 300 400 360 360 C mm 400 150 500 500 500 600 800 100 500 700 S mm 9,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 kg/ 100 pieces 20,0 31,0 32,0 37,0 40,0 40,5 41,0 40,0 41,0 42,0 Material: Helical rod: weather-resistant plastic Application: Helically formed spacers fit to all conductor materials. They are designed up to 500 V. Stand: 21. Juni 2006 Pfad: Helical formed fittings/ Helically formed fittings made from plastic material/ Spacers (BP) for all types of conductors/ Gedruckt am: 16. Januar 2012 51 / 53 ONLINE-CATALOGUE B463/1 Bird flight diverters (ZP) for marking of AAC, AAAC, ACSR, AACSR, Steel, ACS, Copper and Copper alloy conductors RIBE-Order-No. Drawing number Clamping range D mm A mm L mm S mm Mass kg/ 100 pieces Red color ZP 111 021 R ZP 151 026 R ZP 190 033 R ZP 230 038 R ZP 280 053 R ZP 330 063 R F 12000/15 F 12000/6 F 12000/2 F 12000/4 F 12001/2 F 12001/4 8,00 - 11,19 11,20 - 15,19 15,20 - 19,09 19,10 - 23,00 23,01 - 28,00 28,01 - 33,00 125 125 125 125 125 125 240 260 330 380 530 630 12,5 12,5 12,5 12,5 12,5 12,5 13,0 14,0 16,0 18,0 24,5 28,5 ZP 151 026 G ZP 190 033 G ZP 230 038 G ZP 280 053 G ZP 330 063 G F 12000/5 F 12000/1 F 12000/3 F 12001/1 F 12001/3 11,20 - 15,19 15,20 - 19,09 19,10 - 23,00 23,01 - 28,00 28,01 - 33,00 125 125 125 125 125 260 330 380 530 630 12,5 12,5 12,5 12,5 12,5 14,0 16,0 18,0 24,5 28,5 ZP 111 021 W ZP 151 026 W ZP 190 033 W ZP 230 038 W ZP 280 053 W ZP 330 063 W F 12000/13 F 12000/9 F 12000/8 F 12000/7 F 12001/5 F 12001/7 8,0 - 11,19 11,20 - 15,19 15,20 - 19,09 19,10 - 23,00 23,01 - 28,00 28,01 - 33,00 125 125 125 125 125 125 240 260 330 380 530 630 12,5 12,5 12,5 12,5 12,5 12,5 13,0 14,0 16,0 18,0 24,5 28,5 ZP 111 021 S ZP 151 026 S ZP 190 033 S ZP 230 038 S ZP 280 053 S ZP 330 063 S F 12000/14 F 12000/10 F 12000/11 F 12000/12 F 12001/6 F 12001/8 8,00 - 11,19 11,20 - 15,19 15,20 - 19,09 19,10 - 23,00 23,01 - 28,00 28,01 - 33,00 125 125 125 125 125 125 240 260 330 380 530 630 12.5 12,5 12,5 12,5 12,5 12,5 13,0 14,0 16,0 18,0 24,5 28,5 Grey color White color Black color Material: Helical rod: PVC rigid, bare Application: Bird flight diverters ZP are used for marking of conductors and cables to prevent bird collisions. Easy installation by wrapping the spiral around the rope without any tool. Stand: 11. Mai 2007 Pfad: Helical formed fittings/ Helically formed fittings made from plastic material/ Bird flight diverters (ZP) for marking of AAC, AAAC, ACSR, AACSR, Steel, ACS, Copper and Copper alloy conductors/ Gedruckt am: 16. Januar 2012 52 / 53 ONLINE-CATALOGUE B463/2 Bird flight diverters (MP/MPH) for marking of AAC, AAAC, ACSR, AACSR, Steel, ACS, Copper and Copper alloy conductors RIBE-Order-No. Drawing number Fig. Clamping range D1 Mass L1 L2 D2 kg/ 100 pieces Red color MP 151 053 R MP 190 064 R MP 230 078 R F 12037-10/1 F 12037-10/2 F 12037-10/3 1 1 1 11,20 - 15,19 15,20 - 18,99 19,00 - 23,00 530 640 780 500 500 500 12,5 12,5 12,5 20,0 21,0 22,5 MPH 151 053 R MPH 190 064 R MPH 230 078 R F 12037/1 F 12037/2 F 12037/3 2 2 2 11,20 - 15,19 15,20 - 18,99 19,00 - 23,00 530 640 780 500 500 500 12,5 12,5 12,5 21,0 22,0 23,5 MPH 151 053 W MPH 190 064 W MPH 230 078 W F 12037-30/1 F 12037-30/2 F 12037-30/3 2 2 2 11,20 - 15,19 15,20 - 18,99 19,00 - 23,00 530 640 780 500 500 500 12,5 12,5 12,5 21,0 22,0 23,5 MPH 151 053 S MPH 190 064 S MPH 230 078 S F 12037-20/1 F 12037-20/2 F 12037-20/3 2 2 2 11,20 - 15,19 15,20 - 18,99 19,00 - 23,00 530 640 780 500 500 500 12,5 12,5 12,5 21,0 22,0 23,5 Red color White color Black color Material: Helical rod: PVC rigid, bare Application: Bird flight diverters MP/MPH are used for marking of conductors and cables to prevent bird collisions. We recommend to use 3 diverters in “Mercedes"-star configuration. Easy installation by wrapping the spiral around the rope without any tool. Stand: 21. Juni 2006 Pfad: Helical formed fittings/ Helically formed fittings made from plastic material/ Bird flight diverters (MP/MPH) for marking of AAC, AAAC, ACSR, AACSR, Steel, ACS, Copper and Copper alloy conduc Gedruckt am: 16. Januar 2012 53 / 53