Controls MOTOR PROTECTIVE CIRCUIT BREAKERS – MPW (up to 100A) 0800 367 934 Motor Protective Circuit Breakers – MPW (up to 100A) MOTOR PROTECTIVE CIRCUIT BREAKERS – MPW (up to 100A) Summary Motor Protective Circuit Breakers MPW - Overview 4 Motor Protective Circuit Breakers MPW16 / MPW12_S 7 Motor Protective Circuit Breaker MPW25 9 Motor Protective Circuit Breaker MPW65 and MPW100 11 Motor Protective Circuit Breaker MPW25t 13 Motor Protective Circuit Breakers MPW - Accessories 14 Motor Protective Circuit Breakers MPW - Technical Data 22 Motor Protective Circuit Breakers MPW - Dimensions (mm) 35 Motor Protective Circuit Breakers – MPW (up to 100A) 3 Motor Protective Circuit Breakers of MPW line, the best solution for operating and protection of your electric motor. 3 Functions in a Single Product! Electrical Diagram Electrical Diagram Short-circuit protection Switching Switching Overload protection Short-circuit protection I > Overload protection Characteristics Type Number of components Conventional starter Compact starter 3 components (fuse1) + contactor+ termal O/L relay) 1 component (motor circuit breaker termomagnetic) Short-circuit protection Yes Yes Switching Yes Yes Motor overload protection Yes Yes Reset after short-circuit No Yes Yes Yes Overall dimension Reset after overload Larger Smaller Mounting time Long Short No Yes (with accessory) Fuse removal Padlock on handle/button in OFF position Scale cover Safety disconnect for maintenance Operational status signalling Protection degree Number of connections Maximum operation per hour Operation mode No Yes Smaller Bigger Bigger Smaller 15 operations/hour 15 operations/hour Remote Manual Note: 1) Fuse installed on fuse holders IP00. 4 Motor Protective Circuit Breakers – MPW (up to 100A) www. .co.nz Motor Protective Circuit Breakers MPW - Overview With the latest technology and design, the MPW series saves panel space and can be used in most applications in motor control. It combines short-circuit and motor overload protections in just one component. These devices include a three-position rotary ON-TRIP-OFF handle, which can be padlocked in the OFF position. MPW16 up to 16 A / MPW12_S up to 12 A Maximum rated current Imax(Iu) 16 A (screw terminals) 12 A (spring terminals) Number of poles General technical data MPW25 up to 32 A 32 A 3 3 Short-circuit release 13 x lu max 13 x lu max 13 x lu max 13 x lu max Rated operational voltage Ue 690 V 690 V 690 V 690 V 690 V Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Utilization category 19 x lu max IEC 60 947-2 (circuit breaker) A A A A A IEC 60 947-4-1 (motor starter) AC-3 AC-3 AC-3 AC-3 AC-3 Tripping test Yes Yes Yes Yes Yes Overload protection Yes No Yes No Yes Phase failure sensitivity Yes No Yes No Yes Tripping indication Yes Yes Yes Yes Yes Tripping Class Mechanical life Number of operations Electrical life Number of operations 10 - 10 - 10 100,000 100,000 100,000 100,000 100,000 100,000 100,000 100,000 100,000 100,000 Temperature compensation -20...+60 °C - -20...+60 °C - -20...+60 °C Type of protection Thermomagnetic Magnetic Thermomagnetic Magnetic Thermomagnetic Setting overload release Reference code Reference code Ir(A) Terminal type Screw Spring Screw Screw MPW16-3-C016 MPW12-3-C016S MPW16i-3-C016 MPW12i-3-C016S MPW25-3-C016 MPW25i-3-C016 0.16...0.25 MPW16-3-C025 MPW12-3-C025S MPW16i-3-C025 MPW12i-3-C025S MPW25-3-C025 MPW25i-3-C025 MPW25t-3-C025 0.25...0.4 MPW16-3-D004 MPW12-3-D004S MPW16i-3-D004 MPW12i-3-D004S MPW25-3-D004 MPW25i-3-D004 MPW25t-3-D004 0.4...0.63 MPW25t-3-C016 MPW16-3-C063 MPW12-3-C063S MPW16i-3-C063 MPW12i-3-C063S MPW25-3-C063 MPW25i-3-C063 MPW25t-3-C063 0.63...1 MPW16-3-U001 MPW12-3-U001S MPW16i-3-U001 MPW12i-3-U001S MPW25-3-U001 MPW25i-3-U001 MPW25t-3-U001 1...1.6 MPW16-3-D016 MPW12-3-D016S MPW16i-3-D016 MPW12i-3-D016S MPW25-3-D016 MPW25i-3-D016 MPW25t-3-D016 1.6...2.5 MPW16-3-D025 MPW12-3-D025S MPW16i-3-D025 MPW12i-3-D025S MPW25-3-D025 MPW25i-3-D025 MPW25t-3-D025 2.5...4 MPW16-3-U004 MPW12-3-U004S MPW16i-3-U004 MPW12i-3-U004S MPW25-3-U004 MPW25i-3-U004 MPW25t-3-U004 4...6.3 MPW16-3-D063 MPW12-3-D063S MPW16i-3-D063 MPW12i-3-D063S MPW25-3-D063 MPW25i-3-D063 MPW25t-3-D063 6.3...10 MPW16-3-U010 MPW12-3-U010S MPW16i-3-U010 MPW12i-3-U010S MPW25-3-U010 MPW25i-3-U010 MPW25t-3-U010 8...12 - - - - 10...16 MPW16-3-U016 MPW16i-3-U016 MPW25-3-U016 MPW25i-3-U016 MPW25t-3-U016 MPW25-3-U020 MPW25i-3-U020 MPW25t-3-U020 - - MPW25-3-U025 MPW25i-3-U025 - MPW25-3-U032 MPW25i-3-U032 - MPW12-3-U012S - 16...20 20...25 25...32 www. Spring 0.1...0.16 .co.nz MPW12i-3-U012S - Motor Protective Circuit Breakers – MPW (up to 100A) 5 Designed for DIN rail mounting, while lugs for direct panel mounting are also available as accessory. MPW Motor Protective Circuit Breakers are available in five models: MPW16/MPW12_S/MPW25 (45 mm), MPW65 (54 mm) and MPW100 (70 mm) and have been designed for use according to international standards, making them suitable for applications all over the world. MPW65 up to 65 A MPW100 up to 100 A Maximum rated current Imax(Iu) 65 A 100 A Number of poles 3 General technical data Short-circuit release 13 x lu max 3 13 x lu max 13 x lu max Rated operational voltage Ue 690 V 690 V 690 V Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz Use category IEC 60 947-2 (circuit breaker) A A A IEC 60 947-4-1 (motor starter) AC-3 AC-3 AC-3 Tripping test Yes Yes Yes Overload protection Yes No Yes Phase failure sensitivity Yes No Yes Tripping indication Yes Yes Yes Tripping Class Mechanical life Number of operations Electrical life Number of operations 10 - 10 50,000 50,000 50,000 25,000 25,000 25,000 Temperature compensation -20...+60 °C - -20...+60 °C Type of protection Thermomagnetic Magnetic Thermomagnetic Setting overload release Reference code Reference code Screw Screw Ir(A) Terminal type 0.1...0.16 0.16...0.25 0.25...0.4 0.4...0.63 0.63...1 1...1.6 1.6...2.5 2.5...4 - - 4...6.3 - 6.3...10 8...12 10...16 16...20 20...25 25...32 32...40 MPW65-3-U040 MPW65i-3-U040 40...50 MPW65-3-U050 MPW65i-3-U050 50...65 MPW65-3-U065 MPW65i-3-U065 - - 55...75 70...90 MPW100-3-U075 80...100 6 Motor Protective Circuit Breakers – MPW (up to 100A) MPW100-3-U090 MPW100-3-U100 www. .co.nz Motor Protective Circuit Breakers MPW16 / MPW12_S - Overview 12 2 3 11 1 4 6 7 14 5 13 4 16 4 18 17 10 1 15 8 9 1 Motor protective circuit breaker MPW16 2 Feeder terminal FTBBS 3 Three-phase busbars BBS 4 Push-in-lugs PLMP 5 Side auxiliary contact block ACBS 6 Undervoltage release URMP or shunt release SRMP 7 Front auxiliary contact block ACBF 8 Connector ECCMP-C016 (MPW16 + CWC07…16) 9 Compact contactors CWC07…16 10 Insulated enclosure www. .co.nz 11 Block module for power terminals to printed circuit board 12 Block module for auxiliary frontal contact block to printed circuit board 13 Scale cover SCMP 14 Trip signalling block TSB 15 FESTPE twist release emergency pushbutton 16 Motor protective circuit breaker MPW12_S 17 Side auxiliary contact block ACBS_S 18 Front auxiliary contact block ACBF_S Motor Protective Circuit Breakers – MPW (up to 100A) 7 Motor Protective Circuit Breakers MPW16 / MPW12_S - Selection Table • • • • • • With overload and short circuit protection Fixed short circuit release 13 x lu With phase-failure sensitivity according to IEC 60947-4-1 With temperature compensation For use as main switch MPW161) fulfill UL/CSA Motor Protective Circuit Breaker MPW16 / MPW12_S - Thermomagnetic Reference table for selecting protection of three-phase motor 50/60 Hz - 4 poles2) Rated current Setting overload release Instantaneous magnetic trip Reference code Weight 220-240 V 380-415 V 440-480 V 500 V 550-600 V 690 V hp / kW hp / kW hp / kW hp / kW hp / kW hp / kW Iu(A) Ir(A) Irm(A) - - - - - - 0.16 0.1...0.16 - - - - - 0.16 / 0.12 0.25 - - 0.16 / 0.12 0.16 / 0.12 0.16 / 0.12 0.25 / 0.18 - 0.16 / 0.12 0.25 / 0.18 0.25 / 0.18 0.33 / 0.25 0.33 / 0.25 0.16 / 0.12 0.33 / 0.25 0.33 / 0.25 0.5 / 0.37 0.5 / 0.37 0.75 / 0.55 0.33 / 0.25 0.5 / 0.37 1 / 0.75 1 / 0.75 1 / 0.75 0.5 / 0.37 1 / 0.75 1.5 / 1.1 1.5 / 1.1 1.5 / 1.1 1 / 0.75 2 / 1.5 2 / 1.5 2 / 1.5 3 / 2.2 4/3 4 2.5...4 52 MPW16-3-U004 MPW12-3-U004S 1.5 / 1.1 3 / 2.2 4/3 4/3 5 / 3.7 5.5 / 4 6.3 4...6.3 81.9 MPW16-3-D063 MPW12-3-D063S 3 / 2.2 6 / 4.5 7.5 / 5.5 5.5 / 4 7.5 / 5.5 10 / 7.5 10 6.3...10 130 MPW16-3-U010 MPW12-3-U010S 4/3 7.5 / 5.5 - 10 / 7.5 12.5 / 9.2 12.5 / 9.2 12 8...12 156 - MPW12-3-U012S 5 / 3.7 10 / 7.5 12.5 / 9.2 12.5 / 9.2 15 / 11 15 / 11 16 10...16 208 MPW16-3-U016 - Screw type Spring type 2.0 MPW16-3-C016 MPW12-3-C016S 0.16...0.25 3.2 MPW16-3-C025 MPW12-3-C025S 0.4 0.25...0.4 5.2 MPW16-3-D004 MPW12-3-D004S 0.63 0.4...0.63 8.1 MPW16-3-C063 MPW12-3-C063S 1 0.63...1 13 MPW16-3-U001 MPW12-3-U001S 1.5 / 1.1 1.6 1...1.6 20.8 MPW16-3-D016 MPW12-3-D016S 2 / 1.5 2.5 1.6...2.5 32.5 MPW16-3-D025 MPW12-3-D025S kg 0.28 Motor Protective Circuit Breaker MPW16i / MPW12i_S - Magnetic Reference table for selecting protection of three-phase motor 50/60 Hz - 4 poles2) Rated current Instantaneous magnetic trip Reference code Weight 220-240 V 380-415 V 440-480 V 500 V 550-600 V 690 V hp / kW hp / kW hp / kW hp / kW hp / kW hp / kW Iu(A) Irm(A) - - - - - - 0.16 2.0 - - - - - 0.16 / 0.12 0.25 3.2 MPW16i-3-C025 MPW12i-3-C025S - - 0.16 / 0.12 0.16 / 0.12 0.16 / 0.12 0.25 / 0.18 0.4 5.2 MPW16i-3-D004 MPW12i-3-D004S Screw type Spring type MPW16i-3-C016 MPW12i-3-C016S kg - 0.16 / 0.12 0.25 / 0.18 0.25 / 0.18 0.33 / 0.25 0.33 / 0.25 0.63 8.1 MPW16i-3-C063 MPW12i-3-C063S 0.16 / 0.12 0.33 / 0.25 0.33 / 0.25 0.5 / 0.37 0.5 / 0.37 0.75 / 0.55 1 13 MPW16i-3-U001 MPW12i-3-U001S 0.33 / 0.25 0.5 / 0.37 1 / 0.75 1 / 0.75 1 / 0.75 1.5 / 1.1 1.6 20.8 MPW16i-3-D016 MPW12i-3-D016S 0.5 / 0.37 1 / 0.75 1.5 / 1.1 1.5 / 1.1 1.5 / 1.1 2 / 1.5 2.5 32.5 MPW16i-3-D025 MPW12i-3-D025S 1 / 0.75 2 / 1.5 2 / 1.5 2 / 1.5 3 / 2.2 4/3 4 52 MPW16i-3-U004 MPW12i-3-U004S 1.5 / 1.1 3 / 2.2 4/3 4/3 5 / 3.7 5.5 / 4 6.3 81.9 MPW16i-3-D063 MPW12i-3-D063S 3 / 2.2 6 / 4.5 7.5 / 5.5 5.5 / 4 7.5 / 5.5 10 / 7.5 10 130 MPW16i-3-U010 MPW12i-3-U010S 4/3 7.5 / 5.5 - 10 / 7.5 12.5 / 9.2 12.5 / 9.2 12 156 - MPW12i-3-U012S 5 / 3.7 10 / 7.5 12.5 / 9.2 12.5 / 9.2 15 / 11 15 / 11 16 208 MPW16i-3-U016 - 0.28 Notes: 1) cULus certification for MPW with screw connection only. 2) Some motors characteristics may vary according to each manufacture. 8 Motor Protective Circuit Breakers – MPW (up to 100A) www. .co.nz Motor Protective Circuit Breaker MPW25 - Overview 2 20 3 1 6 4 7 1 15 5 11 24 8 4 1 1 12 1 1 16 9 18 21 10 17 19 22 23 1 2 3 4 5 6 14 13 Motor protective circuit breaker MPW25 Feeder terminal FTBBS Three-phase busbars BBS Push-in-lugs PLMP Side auxiliary contact block ACBS Undervoltage release URMP or shunt release SRMP 7 Front auxiliary contact block ACBF 8 Door coupling rotary handle RMMP 9 Connector ECCMP-25 (MPW25 + CWM9...25) 10 Contactors CWM9...25 11 Door coupling rotary handle MRX 12 Front plate FME55 www. .co.nz 13 Standard insulated enclosure MPE55 14 Large insulated enclosure MLPE55 15 Trip signalling block TSB 16 Connector ECCMP-32 (MPW25 + CWM32...40) 17 Contactors CWM32...40 18 Connector ECCMP-C025 (MPW25 + CWC025) 19 Compact contactor CWC025 20Feeder terminal for “Type E” motor starter according to UL LST25 21 Connector ECCMP-C0 (MPW25 + CWC07...16) 22Compact contactor CWC07...16 23Current limiter CLT25 24Scale cover SCMP Motor Protective Circuit Breakers – MPW (up to 100A) 9 Motor Protective Circuit Breaker MPW25 - Selection Table • • • • • • With overload and short circuit protection Fixed short circuit release 13 x lu With phase-failure sensitivity according to IEC 60947-4-1 With temperature compensation For use as main switch MPW25 fulfill UL/CSA Motor Protective Circuit Breaker MPW25 - Thermomagnetic Reference table for selecting protection of three-phase motor 50/60 Hz - 4 poles1) Rated current Setting overload release Instantaneous magnetic trip Reference code 220-240 V 380-415 V 440-480 V 500 V 550-600 V 690 V hp / kW hp / kW hp / kW hp / kW hp / kW hp / kW Iu(A) Ir(A) Irm(A) - - - - - - 0.16 0.1...0.16 2.0 MPW25-3-C016 - - - - - 0.16 / 0.12 0.25 0.16...0.25 3.2 MPW25-3-C025 Weight kg - - 0.16 / 0.12 0.16 / 0.12 0.16 / 0.12 0.25 / 0.18 0.4 0.25...0.4 5.2 MPW25-3-D004 - 0.16 / 0.12 0.25 / 0.18 0.25 / 0.18 0.33 / 0.25 0.33 / 0.25 0.63 0.4...0.63 8.1 MPW25-3-C063 0.16 / 0.12 0.33 / 0.25 0.33 / 0.25 0.5 / 0.37 0.5 / 0.37 0.75 / 0.55 1 0.63...1 13 MPW25-3-U001 0.33 / 0.25 0.5 / 0.37 1 / 0.75 1 / 0.75 1 / 0.75 1.5 / 1.1 1.6 1...1.6 20.8 MPW25-3-D016 0.5 / 0.37 1 / 0.75 1.5 / 1.1 1.5 / 1.1 1.5 / 1.1 2 / 1.5 2.5 1.6...2.5 32.5 MPW25-3-D025 1 / 0.75 2 / 1.5 2 / 1.5 2 / 1.5 3 / 2.2 4/3 4 2.5...4 52 MPW25-3-U004 MPW25-3-D063 1.5 / 1.1 3 / 2.2 4/3 4/3 5 / 3.7 5.5 / 4 6.3 4...6.3 81.9 3 / 2.2 6 / 4.5 7.5 / 5.5 5.5 / 4 7.5 / 5.5 10 / 7.5 10 6.3...10 130 MPW25-3-U010 5 / 3.7 10 / 7.5 12.5 / 9.2 12.5 / 9.2 15 / 11 15 / 11 16 10...16 208 MPW25-3-U016 7.5 / 5.5 12.5 / 9.2 15 / 11 15 / 11 - 20 / 15 20 16...20 260 MPW25-3-U020 - 15 / 11 - 20 / 15 20 / 15 25 / 18.5 25 20...25 325 MPW25-3-U025 12.5 / 9.2 20 / 15 20 / 15 25 / 18.5 30 / 22 30 / 22 32 25...32 416 MPW25-3-U032 0.36 Motor Protective Circuit Breaker MPW25i - Magnetic Reference table for selecting protection of three-phase motor 50/60 Hz - 4 poles1) Rated current Instantaneous magnetic trip hp / kW Iu(A) Irm(A) - 0.16 2.0 220-240 V 380-415 V 440-480 V 500 V 550-600 V 690 V hp / kW hp / kW hp / kW hp / kW hp / kW - - - - - Reference code Weight kg MPW25i-3-C016 - - - - - 0.16 / 0.12 0.25 3.2 MPW25i-3-C025 - - 0.16 / 0.12 0.16 / 0.12 0.16 / 0.12 0.25 / 0.18 0.4 5.2 MPW25i-3-D004 MPW25i-3-C063 - 0.16 / 0.12 0.25 / 0.18 0.25 / 0.18 0.33 / 0.25 0.33 / 0.25 0.63 8.1 0.16 / 0.12 0.33 / 0.25 0.33 / 0.25 0.5 / 0.37 0.5 / 0.37 0.75 / 0.55 1 13 MPW25i-3-U001 0.33 / 0.25 0.5 / 0.37 1 / 0.75 1 / 0.75 1 / 0.75 1.5 / 1.1 1.6 20.8 MPW25i-3-D016 0.5 / 0.37 1 / 0.75 1.5 / 1.1 1.5 / 1.1 1.5 / 1.1 2 / 1.5 2.5 32.5 MPW25i-3-D025 1 / 0.75 2 / 1.5 2 / 1.5 2 / 1.5 3 / 2.2 4/3 4 52 MPW25i-3-U004 MPW25i-3-D063 1.5 / 1.1 3 / 2.2 4/3 4/3 5 / 3.7 5.5 / 4 6.3 81.9 3 / 2.2 6 / 4.5 7.5 / 5.5 5.5 / 4 7.5 / 5.5 10 / 7.5 10 130 MPW25i-3-U010 5 / 3.7 10 / 7.5 12.5 / 9.2 12.5 / 9.2 15 / 11 15 / 11 16 208 MPW25i-3-U016 7.5 / 5.5 12.5 / 9.2 15 / 11 15 / 11 - 20 / 15 20 260 MPW25i-3-U020 - 15 / 11 - 20 / 15 20 / 15 25 / 18.5 25 325 MPW25i-3-U025 12.5 / 9.2 20 / 15 20 / 15 25 / 18.5 30 / 22 30 / 22 32 416 MPW25i-3-U032 0.36 Note: 1) Some motors characteristics may vary according to each manufacturer. 10 Motor Protective Circuit Breakers – MPW (up to 100A) www. .co.nz Motor Protective Circuit Breaker MPW65 and MPW100 - Overview 10 2 4 1 6 5 3 8 9 7 2 12 11 14 15 16 13 18 17 1 Motor protective circuit breaker MPW65 2 Push-in-lugs PLMP 3 Side auxiliary contact block ACBS 4 Undervoltage release URMP or shunt release SRMP 5 Frontal auxiliary contact block ACBF 6 Trip signalling block TSB 7 Door coupling rotary handle MRX65 8 Door coupling rotary handle RMMP65 9 Scale cover SCMP 10 Feeder terminal for “Type E” motor starter according to UL LST65 www. .co.nz 11 Motor protective circuit breaker MPW100 12 IB insulators 13 Side auxiliary contact block ACBS_ MPW100 14 Undervoltage release URMP_ MPW100 or shunt release SRMP_ MPW100 15 Frontal auxiliary contact block ACBF_ MPW100 16 Trip signalling block TSB_ MPW100 17 Door coupling rotary handle MR MPW100 18 Door coupling rotary handle MRX100 Motor Protective Circuit Breakers – MPW (up to 100A) 11 Motor Protective Circuit Breaker MPW65 - Selection Table • • • • • • With overload and short circuit protection Fixed short circuit release 13 x lu With phase-failure sensitivity according to IEC 60947-4-1 With temperature compensation For use as main switch MPW65 fulfill UL/CSA Motor Protective Circuit Breaker MPW65 - Thermomagnetic Reference table for selecting protection of three-phase motor 50/60 Hz - 4 poles1) Setting overload release Instantaneous magnetic trip 380-415 V 440-480 V 500 V 550-600 V 690 V Rated current hp / kW hp / kW hp / kW hp / kW hp / kW hp / kW Iu(A) Ir(A) Irm(A) 15 / 11 25 / 18.5 30 / 22 30 / 22 - 50 / 37 40 32...40 520 220-240 V Reference code Weight kg MPW65-3-U040 - 30 / 22 40 / 30 40 / 30 50 / 37 60 / 45 50 40...50 650 MPW65-3-U050 25 / 18.5 40 / 30 50 / 37 60 / 45 60 / 45 75 / 55 65 50...65 845 MPW65-3-U065 1.07 Motor Protective Circuit Breaker MPW65i - Magnetic Reference table for selecting protection of three-phase motor 50/60 Hz - 4 poles1) 380-415 V 440-480 V 500 V 550-600 V 690 V Rated current Instantaneous magnetic trip hp / kW hp / kW hp / kW hp / kW hp / kW hp / kW Iu(A) Irm(A) 15 / 11 25 / 18.5 30 / 22 30 / 22 - 50 / 37 40 520 220-240 V Reference code Weight kg MPW65i-3-U040 - 30 / 22 40 / 30 40 / 30 50 / 37 60 / 45 50 650 MPW65i-3-U050 25 / 18.5 40 / 30 50 / 37 60 / 45 60 / 45 75 / 55 65 845 MPW65i-3-U065 1.07 Motor Protective Circuit Breaker MPW100 - Selection Table • • • • • • With overload and short circuit protection Fixed short circuit release 13 x lu With phase-failure sensitivity according to IEC 60947-4-1 With temperature compensation For use as main switch MPW100 fulfill UL/CSA Motor Protective Circuit Breaker MPW100 - Thermomagnetic Reference table for selecting protection of three-phase motor 50/60 Hz - 4 poles1) Setting overload release Instantaneous magnetic trip 220-240 V 380-415 V 440-480 V 500 V 550-600 V 690 V Rated current hp / kW hp / kW hp / kW hp / kW hp / kW hp / kW Iu(A) Ir(A) Irm(A) 25 / 18.5 50 / 37 60 / 45 60/45 75 / 55 75 / 55 75 55...75 975 Reference code Weight kg MPW100-3-U075 30 / 22 60 / 45 75 / 55 75/55 75 / 55 100 / 75 90 70...90 1,170 MPW100-3-U090 40 / 30 60 / 45 75 / 55 75/55 75 / 55 125 / 90 100 80...100 1,300 MPW100-3-U100 2.2 Note: 1) Some motors characteristics may vary according to each manufacturer. 12 Motor Protective Circuit Breakers – MPW (up to 100A) www. .co.nz Motor Protective Circuit Breaker MPW25t - Selection Table Motor Protective Circuit Breaker for Protection of Transformers or Motors with High Starting Current • • • • • With overload and short circuit protection Fixed short circuit release 19 x lu With phase-failure sensitivity according to IEC 60947-4-1 With temperature compensation For use as main switch Reference table for selecting protection of three-phase motor 50/60 Hz - 4 poles1) Rated current Setting overload release Instantaneous magnetic trip Short-circuit breaking capacity 400/415 V ac 220-240 V 380-415 V 440-480 V 500 V 690 V hp / kW hp / kW hp / kW hp / kW hp / kW Iu(A) Ir(A) Irm(A) Icu(kA) - - - - - 0.16 0.1...0.16 3 100 Reference code Weight kg MPW25t-3-C016 - - - - 0.16 / 0.12 0.25 0.16...0.25 4.8 100 MPW25t-3-C025 - - 0.16 / 0.12 0.16 / 0.12 0.25 / 0.18 0.4 0.25...0.4 7.6 100 MPW25t-3-D004 MPW25t-3-C063 - 0.16 / 0.12 0.25 / 0.18 0.25 / 0.18 0.33 / 0.25 0.63 0.4...0.63 12 100 0.16 / 0.12 0.33 / 0.25 0.33 / 0.25 0.5 / 0.37 0.75 / 0.55 1 0.63...1 19 100 MPW25t-3-U001 0.33 / 0.25 0.5 / 0.37 1 / 0.75 1 / 0.75 1.5 / 1.1 1.6 1...1.6 30.4 100 MPW25t-3-D016 0.5 / 0.37 1 / 0.75 1.5 / 1.1 1.5 / 1.1 2 / 1.5 2.5 1.6...2.5 47.5 100 MPW25t-3-D025 1 / 0.75 2 / 1.5 2 / 1.5 2 / 1.5 4/3 4 2.5...4 76 100 MPW25t-3-U004 1.5 / 1.1 3 / 2.2 4/3 4/3 5.5 / 4 6.3 4...6.3 119.7 100 MPW25t-3-D063 MPW25t-3-U010 3 / 2.2 6 / 4.5 7.5 / 5.5 5.5 / 4 10 / 7.5 10 6.3...10 190 100 5 / 3.7 10 / 7.5 12.5 / 9.2 12.5 / 9.2 15 / 11 16 10...16 304 50 MPW25t-3-U016 7.5 / 5.5 12.5 / 9.2 15 / 11 15 / 11 20 / 15 20 16...20 380 50 MPW25t-3-U020 0.36 Applications of the motor protective circuit breaker MPW25t for the protection of transformers: When the control of transformers is protected on their primary winding, the high in-rush current caused by starting the transformer normally causes an unwanted trip of the protection devices. Due to this fact, circuit breakers in the MPW25t series are designed with an over current release set to approximately 19 times the rated operational current, allowing the breakers to be used for the protection of transformers. Miliseconds The curves show average tolerance range values for an ambient temperature of 20 °C, starting in cold state. Thermal trip time when working in operating temperature is reduced to around 25% of the presented values. Under normal operating conditions, all 3 circuit breaker phases must be conducting. Seconds The tripping characteristic shows the motor circuit breaker trip time in relation to the rated current. Minutes Tripping Characteristics X Rated operational current Note: 1) Some motors characteristics may vary according to each manufacturer. www. .co.nz Motor Protective Circuit Breakers – MPW (up to 100A) 13 Motor Protective Circuit Breakers MPW - Accessories Front Auxiliary Contact Block - ACBF For use with Illustrative picture Auxiliary contacts NO NC Reference code MPW16/16i MPW25/25i/25t MPW65/65i ACBF-11 1) MPW12_S/12i_S Weight kg 0.024 ACBF-11S 1 1 MPW100 ACBF-11 MPW100 0.018 Reference code Weight kg Left Side Auxiliary Contact Block - ACBF For use with Illustrative picture MPW16/16i MPW25/25i/25t MPW65/65i Auxiliary contacts NO NC 1 1 ACBS-11 2 - ACBS-20 - 2 ACBS-02 1) 0.045 MPW12_S/12i_S MPW100 1 1 ACBS-11S 2 - ACBS-20S - 2 ACBS-02S 1 1 ACBS-11 MPW100 2 - ACBS-20 MPW100 - 2 ACBS-02 MPW100 0.030 Note: 1) The following accessories can be assembled at the same time: 1 ACBF + 1 URMP/SRMP + 1 TSB or 1 ACBS + 1 URMP/SRMP + 1 TSB. 14 Motor Protective Circuit Breakers – MPW (up to 100A) www. .co.nz Trip Signalling Block - TSB For use with Illustrative picture Description Reference code Weight kg TSB 0.130 - Equipped with 2 auxiliary contacts (1NO + 1NC) for overload trip signalling and 2 other auxiliary contacts (1NO + 1NC) for short-circuit trip signalling. MPW16/16i MPW25/25i/25t MPW65/65i - To reset the circuit breaker after a short-circuit, the flag must be manually reset after the cause of the failure has been solved. 1) - Lateral auxiliary contacts can be assembled together with the trip signalling block. - Left side assembly only. - Equipped with 2 auxiliary contacts (1NO + 1NC) for overload and short-circuit trip signalling. TSB AT11 MPW100 - Left side assembly only. MPW100 - 0.060 - Equipped with 2 auxiliary contacts (1NO + 1NC) for short-circuit trip signalling. TSB SC-11 MPW100 - Left side assembly only. Undervoltage Release - URMP For use with Illustrative picture MPW16/16i MPW25/25i/25t MPW65/65i 1) Note: - Operating voltage > 0.85 x Ue - Non operating voltage 0.35...0.7 x Ue MPW100 Note: - Operating voltage > 0.85 x Ue - Non operating voltage 0.35...0.7 x Ue Voltage2) Reference code Weight kg 220 V 60 Hz 208 V 60 Hz 95 V 50 Hz / 110 V 60 Hz 24 V 50/60 Hz 110-115 V 50 Hz / 127 V 60 Hz 230-240 V 50 Hz / 277 V 60 Hz 380 V 50 Hz / 440 V 60 Hz 400-415 V 50 Hz / 480 V 60 Hz 500 V 50 Hz / 600 V 60 Hz 110 V 50 Hz / 120 V 60 Hz 240 V 60 Hz 220 V 50 Hz / 255 V 60 Hz 325 V 50 Hz / 380 V 60 Hz 220 V 50/60 Hz 208 V 50 Hz / 200-240 V 60 Hz URMP V25 URMP V83 URMP V15 URMP D02 URMP V19 URMP V37 URMP V42 URMP V47 URMP V56 URMP V18 URMP V29 URMP V32 URMP V41 URMP D23 URMP V30 0.130 110 V 50 Hz / 120 V 60 Hz 220-230 V 50 Hz / 240-260 V 60 Hz 380-400 V 50 Hz / 440-460 V 60 Hz 200 V 50 Hz / 200-220 V 60 Hz URMP V18 MPW100 URMP V33 MPW100 URMP V43 MPW100 URMP V01 MPW100 0.018 Notes: 1) The following accessories can be coupled at the same time: 1 ACBF + 1 URMP/SRMP + 1 TSB or 1 ACBS + 1 URMP/SRMP + 1 TSB; 2) Other voltages avaliable. www. .co.nz Motor Protective Circuit Breakers – MPW (up to 100A) 15 Shunt Release - SRMP For use with Voltage2) Reference code Weight kg 20-24 V 50/60 Hz 40-48 V 50/60 Hz 100-127 V 50/60 Hz 200-240 V 50/60 Hz 365-440 V 50/60 Hz SRMP D51 SRMP D54 SRMP D59 SRMP D65 SRMP D69 0.130 110 V 50 Hz / 120 V 60 Hz 220-230 V 50 Hz / 240-260 V 60 Hz 380-400 V 50 Hz / 440-460 V 60 Hz 200 V 50 Hz / 200-220 V 60 Hz SRMP V18 MPW100 SRMP V33 MPW100 SRMP V43 MPW100 SRMP VD1 MPW100 0.040 Description2) Reference code Weight kg IB MPW100 0.010 Illustrative picture MPW16/16i MPW25/25i/25t. MPW65/65i 1) Note: - Operating voltage > 0.7 x Ue MPW100 Note: - Operating voltage > 0.7 x Ue Insulators for UL - IB For use with Illustrative picture - Insulators for increasing creepage distance and clearances according to UL requirements. MPW100 Package with 4 pieces. Block Modules for Motor Protective Circuit Breaker Assembly + Contactors - ECCMP, C2075 and C20100 For use with Illustrative picture MPW16/16i - For direct connection (electrical and mechanical) of motor circuit breakers to contactors. MPW25/25i/25t Contactors Reference code CWC07…16 ECCMP-C016 CWC07…16 CWC025 CWM9…25 CWM32...40 ECCMP-C0 ECCMP-C025 ECCMP-25 ECCMP-32 Description Note: Not applicable to CWM contactors with DC coils. Width: 45 mm Rated current: 20 A Length: 75 mm 0.025 C2075 CWC07...16 CWM9…25 MPW16/16i MPW25/25i/25t Weight kg Width: 45 mm Rated current: 20 A Length: 100 mm 0.025 C20100 Notes: 1) The following accessories can be coupled at the same time: 1 ACBF + 1 URMP/SRMP + 1 TSB or 1 ACBS + 1 URMP/SRMP + 1 TSB; 2) Other voltages avaliable. 16 Motor Protective Circuit Breakers – MPW (up to 100A) www. .co.nz Door Coupling Rotary Handle - RMMP and MR For use with Illustrative picture Description Handle color - Degree of protection IP55; - Shows circuit breaker position “I”(ON) or “O”(OFF); - Adjustable shaft length. There are 2 standard shaft sizes: 130-155 mm (Model 130) and 330-355 mm (Model 330). To assembled the handle on the circuit breaker the shaft must have a length of at least 80 mm; - Up to 3 padlocks can be used in the OFF position. This blocks circuit breaker operation and opens panel door; RMMP-130 RMMP-330 RMMP-130E Red/Yellow RMMP-330E RMMP65-130 Black RMMP65-330 - Handle can be mounted on panels with a thickness of 1 to 5 mm; MPW65/65i - Handle can be assembled even with circuit breaker turned in 90º position. - Panel door can be opened in ON position (thermometry); - Degree of protection: MRX = IP65/Nema 4X; MPW25/25i/25t RMMP65-130E Red/Yellow RMMP65-330E Black - Shows circuit breaker position “I”(ON) or “O”(OFF); - Adjustable shaft length. There are 2 standard shaft sizes: 130-155 mm (Model 130) and 330-355 mm (Model 330). To assemble the handle ON the circuit breaker the shaft must have a length of at least 80 mm; - Up to 3 padlocks can be used in the OFF position. This blocks circuit breaker operation and opens panel door Handle can be mounted on panels with a thickness of 1 to 5 mm. MPW65/65i Weight kg Black - Panel door can only be opened in OFF position; MPW25/25i/25t Reference code Red/Yellow Black Red/Yellow MRX-130 MRX-330 0.250 MRX-130E MRX-330E MRX65-130 MRX65-330 MRX65-130E MRX65-330E - Degree of protection: IP65; MR MPW100-115 - Shows circuit breaker position “I”(ON) or “O”(OFF); MPW100 - - Adjustable shaft length. There are 2 standard shaft sizes: 220-282 mm (Model 115) and 220-482 mm (Model 315); Grey MR MPW100-315 - Up to 3 padlocks can be used in the OFF position. This blocks circuit breaker operation and opens panel door. Front Plate - FME55 For use with Illustrative picture Description Handle color Reference code Weight kg Black FME55 0.2 Red with yellow background FME55E 0.2 - For motor protective circuit breaker assembly in panel door or side; - Degree of protection: IP55; - MPW25 fits directly into base; - Rotary handle in enclosure fits directly into MPW25 handle; MPW25/25i/25t - Handle can be locked with up to 3 padlocks at OFF position; - Enables accessory installation: ACBF11 + ACBS + URMP/SRMP; - PL signalling lamps can be installed on enclosure (without ACBF-11). www. .co.nz Motor Protective Circuit Breakers – MPW (up to 100A) 17 Standard Insulated Enclosure - MPE For use with Illustrative picture Description Terminals - Degree of protection: IP41; - Two M25 metric cable entry knockouts, top and bottom; - Allows installing: MPW16 + ACBF11/PL lamps + ACBS. - Degree of protection: IP66; - Two M25 metric cable entry knockouts, top and bottom; With ground terminals Weight kg MPE41G - With neutral and ground terminals 0.510 MPE41GN With ground terminals MPE66G With neutral and ground terminals - Enable to increase degree of protection from MPE41 (IP41) to IP66. - - KITIP66 0.10 - Twist to unlock emergency pushbutton with IP66 degree of protection. - - FESTPE 0.080 Black MPE55G 0.510 Red with yellow background MPE55GE 0.510 Black MPE55GN 0.420 Red with yellow background MPE55GNE 0.420 Terminals Handle color Reference code Weight kg Black MLPE55G 0.54 With ground terminals Red with yellow background MLPE55G-E 0.54 Black MLPE55GN 0.45 Red with yellow background MLPE55GN-E 0.45 Description Reference code Weight kg Main terminal connection CIC16 0.023 Main terminal connection with auxiliary contact connection CIC16A 0.045 - Degree of protection: IP55; - For use on emergency-stop switches to IEC/EN 60204; With ground terminals - Allows installing: MPW25 + ACBF11/PL lamps + ACBS; MPW25/25i/25t Reference code - - Allows installing: MPW16 + ACBF11/PL lamps + ACBS. MPW16/16i Handle color - Two M25 metric cable entry knockouts, top and bottom; - Handle can be locked with up to 3 padlocks at OFF position. With neutral and ground terminals 0.510 MPE66GN Large Insulated Enclosure - MLPE55 For use with Illustrative picture Description - Degree of protection: IP55; - For use on emergency-stop switches to IEC/EN 60204; - For use with MPW25 + URMP/SRMP + ACBF11 + ACBS + PL lamps; MPW25/25i/25t - Two M25 metric cable entry knockouts. top and bottom; - Handle can be locked with up to 3 padlocks at OFF position. With neutral and ground terminals Block Module for Printed Circuit Board - CIC For use with Illustrative picture MPW16/16i 18 Motor Protective Circuit Breakers – MPW (up to 100A) www. .co.nz Pilot Light - PL For use with Illustrative picture Lamp color Red All models Green White Voltage Reference code 24 V 50/60 Hz / V dc PL24-E26 110...130 V 50/60 Hz PL130-D61 210...230 V 50/60 Hz PL230-D78 400...560 V 50/60 Hz PL560-D79 24 V 50/60 Hz / V dc PL24G-E26 110...130 V 50/60 Hz PL130G-D61 210...230 V 50/60 Hz PL130G-D78 400...560 V 50/60 Hz PL560G-D79 24 V 50/60 Hz / V dc PL24W-E26 110...130 V 50/60 Hz PL130W-D61 210...230 V 50/60 Hz PL130W-D78 400...560 V 50/60 Hz PL560W-D79 Weight kg 0.005 Motor Protective Circuit Breaker Mounting Adapter + Contactor - MA For use with Illustrative picture Description Used for direct on line starters MPW16/16i MPW25/25i/25t Contactors Reference code Weight kg CWC07...25 CWM9…25 MA45DOL 0.025 2 x CWC07...25 CWM9...25 MA90RVS 0.025 2 x CWC07...25 CWM9…25 MA90SDS 0.025 45 mm width Used for reversing starters MPW16/16i MPW25/25i/25t 90 mm width Used for star-delta motor starters MPW16/16i MPW25/25i/25t 90 mm width www. .co.nz Motor Protective Circuit Breakers – MPW (up to 100A) 19 Three-Phase Feeder Terminal - FTBBS and LST25 For use with Illustrative picture Description Reference code Weight kg FTBBS 0.042 LST25 0.042 LST65 0.179 - For feeding the busbars; - Rated insulation voltage: 690 V ac; MPW16/16i. MPW25/25i/25t -Ie: 63 A; - Terminals: 6-25 mm2 rigid wire and 6-16 mm2 flexible wire with terminal. -Block module for “ Type E“ Combination motor Controller” in accordance with UL (LST25+MPW+TSB); - Rated insulation voltage: 690 V ac; MPW25/25i/25t -Ie: 63 A. - Terminals: 8-20 AWG. -Block module for “ Type E“ Combination motor Controller” in accordance with UL (LST65+MPW+TSB); - Rated insulation voltage: 690 V ac; MPW65/65i -Ie: 63 A; - Terminals: 4-8 AWG. Three-Phase Busbars for Circuit Breakers Without Side Fitted Auxiliary Contacts - BBS45 For use with Illustrative picture Description - For parallel blocking of side-by-side mounted circuit breakers. without side auxiliary contacts; - Enables the use of frontal auxiliary contact block ACBF-11; MPW16/16i MPW25/25i/25t -Ue: 690 V ac; -Ie: 63 A. Numbers of circuit breakers Reference code Weight kg 2 BBS45-2 0.044 3 BBS45-3 0.071 4 BBS45-4 0.102 5 BBS45-5 0.122 Three-Phase Busbars for Motor Protection Circuit Breakers with Side Fitted Auxiliary Contacts - BBS54 For use with Numbers of circuit breakers Reference code Weight kg - For parallel blocking of side-by-side mounted circuit breakers; 2 BBS54-2 0.047 - Enables the use of side auxiliary contact block ACBS mounted on each motor protective circuit breaker; 3 BBS54-3 0.077 4 BBS54-4 0.102 5 BBS54-5 0.134 Reference code Weight kg CLT25 0.310 Illustrative picture MPW16/16i MPW25/25i/25t Description -Ue: 690 V ac; -Ie: 63 A. Current Limiter - CLT25 For use with Illustrative picture Description - For protecting electrical circuits where high short-circuit breaking capacity is required: MPW25/25i/25t 100 kA @ 500 V ac; Note: This accessory must be used together with a MPW motor protective circuit breaker. 20 Motor Protective Circuit Breakers – MPW (up to 100A) www. .co.nz Shrouded for Unused Terminals - CSD For use with Illustrative picture Description - Protection against direct contact to unused terminals on energized BBS45 and BBS54 three-phase busbars. BBS45 and BBS54 Reference code Weight kg CSD 0.020 Reference code Weight kg SCMP 0.005 Reference code Weight kg PLMP 0.05 Scale Cover - SCMP For use with Illustrative picture MPW16 MPW25/25t MPW65 Description - Protects the current adjustment dial against direct contact while enabling the adjusted current to be viewed. Push-In-Lugs - PLMP For use with Illustrative picture MPW16/16i MPW25/25i/25t MPW65/65i www. Description - For direct assembly of motor protective circuit breaker onto any surface using screws. .co.nz Motor Protective Circuit Breakers – MPW (up to 100A) 21 Motor Protective Circuit Breakers MPW - Technical Data Reference code MPW16 MPW16i MPW12_S MPW12i_S 16 A 16 A 12 A 12 A Maximum rated current imax(iu) Number of poles 3 3 3 3 Instantaneous short-circuit 13 x Iemax. 13 x Iemax. 13 x Iemax. 13 x Iemax. Rated operational voltage Ue 690 V1) 690 V1) 690 V1) 690 V1) Rated operational frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Insulation voltage Ui 690 V 690 V 690 V 690 V Rated impulse withstand voltage Uimp 6 kV 6 kV 6 kV 6 kV IEC 60 947-2 (circuit breaker) A A A A IEC 60 947-4-1 (motor starter) AC-3 AC-3 AC-3 AC-3 Tripping test Yes Yes Yes Yes Overload protection Yes No Yes No Phase failure sensitivity Yes No Yes No Tripping indication Yes Yes Yes Yes Tripping class 10 - 10 - 15 15 15 15 Altitude (m) 2,000 2,000 2,000 2,000 Degree of protection IP20 IP20 IP20 IP20 Utilization category Maximum operation/hour Operations/hour Mechanical life span Number of operations 100,000 100,000 100,000 100,000 Electrical life span Number of operations 100,000 100,000 100,000 100,000 Ambient temperatures allowed Transport and storage -50...+80 °C -50...+80 °C -50...+80 °C -50...+80 °C Operation1) -20...+70 °C -20...+70 °C -20...+70 °C -20...+70 °C Temperature compensation -20...+60 °C - -20...+60 °C - 15 15 15 15 Resistance to impact (g) Standards IEC/EN 60 947-1. DIN VDE 0660 (part 100) Yes Yes Yes Yes IEC/EN 60 947-2. DIN VDE 0660 (part 101) Yes Yes Yes Yes IEC/EN 60 947-4-1. DIN VDE 0660 (part 102) Yes Yes Yes Yes Terminal capacity Type of terminal Tightening torque N.m lb.in Flat Flat - - 1.2...1.7 1.2...1.7 - - 11...16 11...16 - - Philips (Nº2) Philips (Nº2) - - Width (mm) 45 45 45 45 Height (mm) 90 90 100 100 Depth (mm) 77 77 77 77 Type of screws Dimensions Altitude - Correction Factor The MPW motor protective circuit breakers do not undergo any change to their specified performance when applied at an altitude of up to 2,000 meters above sea level. However, as the altitude increases, the atmospheric properties vary in terms of dielectric rigidness and pressure. Altitude (above sea level) - h Rated operational voltage Ue Current correction factor Iu h ≤ 2,000 m 690 V 1 x Iu 2,000 < h ≤ 3,000 m 550 V 0.96 x Iu 3,000 < h ≤ 4,000 m 480 V 0.93 x Iu 4,000 < h ≤ 5,000 m 420 V 0.90 x Iu Therefore, current and voltage correction factors must be applied for altitudes exceeding 2,000 meters, as shown in the following table. Note: 1) Reduce current for temperatures exceeding +60 °C (87% to 70 °C). 22 Motor Protective Circuit Breakers – MPW (up to 100A) www. .co.nz Reference code Maximum rated current imax(iu) Number of poles Instantaneous short-circuit MPW25 MPW25i MPW25t MPW65 MPW65i MPW100 32 A 32 A 32 A 65 A 65 A 100 A 3 3 3 3 3 3 13 x Iemax. 13 x Iemax. 19 x Iemax. 13 x Iemax. 13 x Iemax. 13 x Iemax. Rated operational voltage Ue 690 V1) 690 V1) 690 V1) 690 V 690 V 690 V Rated operational frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Insulation voltage Ui 690 V 690 V 690 V 690 V 690 V 1,000 V Rated impulse withstand voltage Uimp 6 kV 6 kV 6 kV 6 kV 6 kV 8 kV IEC 60 947-2 (circuit breaker) A A A A A A IEC 60 947-4-1 (motor starter) AC-3 AC-3 AC-3 AC-3 AC-3 AC-3 Utilization category Tripping test Yes Yes Yes Yes Yes Yes Overload protection Yes No Yes Yes No Yes Phase failure sensitivity Yes No Yes Yes No Yes Tripping indication Yes Yes Yes Yes Yes Yes Tripping class 10 - Yes 10 - 10 Maximum operating frequency Operations/hour 15 15 15 15 15 25 2,000 2,000 2,000 2,000 2,000 2,000 Altitude (m) Degree of protection IP20 IP20 IP20 IP20 IP20 IP20 Mechanical life span Number of operations 100,000 100,000 100,000 50,000 50,000 50,000 Electrical life span Number of operations 100,000 100,000 100,000 25,000 25,000 25,000 Ambient temperatures allowed Transport and storage -50...+80 °C -50...+80 °C -50...+80 °C -50...+80 °C -50...+80 °C -50...+80 °C Operation1) -20...+70 °C -20...+70 °C -20...+70 °C -20...+70 °C -20...+70 °C -20...+60 °C Temperature compensation -20...+60 °C - - -20...+60 °C - -20...+60 °C 15 15 15 15 15 25 Resistance to impact (g) Standards IEC/EN 60 947-1. DIN VDE 0660 (part 100) Yes Yes Yes Yes Yes Yes IEC/EN 60 947-2. DIN VDE 0660 (part 101) Yes Yes Yes Yes Yes Yes IEC/EN 60 947-4-1. DIN VDE 0660 (part 102) Yes Yes Yes Yes Yes Yes Terminal capacity Type of terminal N.m Tightening torque lb.in Flat Flat Flat Box Box Box 2...2.5 2...2.5 2...2.5 4...6 4...6 4...6 18...22 18...22 18...22 35...55 35...55 35...53 Philips (Nº2) Philips (Nº2) Philips (Nº2) Allen (4 mm) Allen (4 mm) Allen (4 mm) Width (mm) 45 45 45 54 54 70 Height (mm) 97 97 97 125 125 165 Depth (mm) 98 98 98 157 157 171 Type of screws Dimensions DC Operation The MPW16, MPW25 and MPW65 motor protective circuit breakers can also be used for operating continuous current loads. For such operation it is necessary to connect 2 or 3 poles in series. See recommended circuits and their voltage limits in the table on the right. Circuits Max. V dc Notes 150 V dc System not grounded 2 pole series connected 300 V dc System grounded 2 pole series connected 450 V dc System grounded 3 pole series connected Time constant t = 5ms Short-circuit breaking capacity Icu = 10 kA for all configurations. Note: 1) Reduce current for temperatures exceeding +60 °C (87% to 70 °C). www. .co.nz Motor Protective Circuit Breakers – MPW (up to 100A) 23 Main Terminal Capacity Reference code Type Number of conductors Cross-section MPW16/16i Rigid or flexible cable 1 or 2 1...4 mm2 18...12 AWG MPW25/25i/25t Rigid or flexible cable 1 or 2 1...2.5 mm2 2.5...6 mm2 14...8 AWG1) Type 1 conductor connection on top only Cross-section Rigid cable 1...35 mm2 Cable without terminal 1.5...35 mm2 Cable with terminal 1...35 mm2 1.5...35 mm2 Flexible cable 17...2 AWG Type 1 conductor connection on bottom only Cross-section Rigid cable 2.5...35 mm2 Cable without terminal 6...35 mm2 Cable with terminal 2.5...35 mm2 6...35 mm2 Flexible cable MPW65/65i 13...2 AWG Type Connection of 2 condutors Cross-section Rigid cable 1...35 mm2 Cable without terminal 1.5...35 mm2 Cable with terminal Conductor on top (A) 1...35 mm2 1.5...35 mm2 Flexible cable 17...2 AWG A Type Cross-section B Rigid cable 2.5...35 mm2 Cable without terminal 6...35 mm2 Conductor on bottom (B) Cable with terminal 2.5...35 mm2 6...35 mm2 Flexible cable 13...2 AWG Type Number of conductors Cross-section 2.5...70 mm2 1 12...2/0 AWG Rigid cable 2.5...50 mm2 2 MPW100 12...1/0 AWG 2.5...50 mm2 1 12...1/0 AWG Flexible cable 2.5...35 mm2 2 10...2 AWG Mounting Configurations for MPW Motor Protective Circuit Breaker Live or grounded parts distance to the circuit breaker Description Ue MPW16 Up to 690 V Minimum distance between the circuit breaker and live or grounded parts (mm) A B C 90 20 75 95 Up to 500 V 9 30 Up to 690 V 30 50 95 MPW65 Up to 690 V 10 50 150 MPW100 Up to 690 V 30 150 167 MPW25 The motor protective circuit breaker can be mounted in any position, but according to IEC 60447 standard, the “On - I” indicator must be to the right, or up. Note: 1) 8 AWG for flexible cable only. 24 Motor Protective Circuit Breakers – MPW (up to 100A) www. .co.nz Auxiliary Contact Block - ACB Reference code ACBF-11 ACBS-11. ACBS-20. ACBS-02. TSB For use with MPW16/16i. MPW25/25i/25t. MPW65/65i Utilization category 24 V ac 220-230 V ac 24 V ac 230 V ac 400 V ac 690 V ac 2A 0.5 A 6A 6A 3A 1A AC-15 AC-12 2.5 A DC-13 10 A 10 A 10 A 10 A 24 V dc 48 V dc 2.5 A 60 V dc 24 V dc 110 V dc 220 V dc 440 V dc 1A 0.3 A 0.15 A 2A 0.5 A 0.25 A 0.1 A Type of terminal Flat Type of screw Philips (Nº2) Tightening torque 0.8…1.2 N.m (7…10 lb.in) Rigid cable 1 or 2 x (0.5...1.5 mm2). 1 or 2 x (0.75…2.5 mm2). 2 x (18…14 AWG) Flexible cable Backup fuses gL/gG 10 A Reference code ACBF-11 MPW100 ACBS-11/ACBS-20/ACBS-02/TSB AT-11 MPW100 For use with MPW100 Utilization category AC-15 DC-13 240 V ac 24 V ac 3A 6A 240 V ac 4A 24 V dc 220 V dc 24 V dc 220 V dc 1A 0.1 A 2A 0.25 A Type of screw Philips (Nº2) Tightening torque 0.8…1.2 N.m (7…10 lb.in) 1 (0.5…2.5 mm2 / 20…14 AWG) Rigid cable 1 or 2 x (0.5…2.5 mm2 / 20…14 AWG) 1 (0.5...4 mm / 20...10 AWG) or 2 (0.75...2.5 mm / 18...14 AWG) Flexible cable 2 2 Back-up fuses gL/gG 16 A Undervoltage Release - URMP Reference code For use with URMP URMP V_ _ MPW100 MPW16/16i. MPW25/25i/25t. MPW65/65i MPW100 Operating voltage (enables cir. breaker switch on) 0.85...1.1xUs Non-operating voltage (guarantees circuit breaker switch OFF) 0.7...0.35xUs Energization consumption 20.2 VA / 13 W Consumption 7.2 VA / 2.4 W 8.5 VA / 6 W 3 VA / 1.2 W Max. opening time 20ms Type of terminal Flat Type of screws Philips (Nº2) Tightening torque 0.8…1.2 N.m (7…10 lb.in) Rigid cable 1 or 2 x (0.5...2.5 mm2 / 20...14 AWG) 1 or 2 x (0.5...1.5 mm2). 1 or 2 x (0.75…2.5 mm2). 2 x (18…14 AWG) Flexible cable Back-up fuses gL/gG 1 (0.5...4 mm2 / 20...10 AWG) or 2 x (0.75...2.5 mm2 / 18...14 AWG) 10 A Shunt Release - SRMP Reference code For use with SRMP SRMP-K_ _ MPW100 MPW16/16i. MPW25/25i/25t. MPW65/65i MPW100 Operating voltage (guarantee circuit breaker switch OFF) Consumption - Energization Maximum opening time 0.7...1.1xUs 20.2 VA / 13 W 8.5 VA / 6 W 20ms Type of terminal Flat Type of screw Philips (Nº2) Tightening torque 0.8…1.2 N.m (7…10 lb.in) Rigid cable Back-up fuses gL/gG www. 1 ou 2 x (0.5...2.5 mm2 / 20...14 AWG) 1 or 2 x (0.5...1.5 mm2). 1 or 2 x (0.75…2.5 mm2) 2 x (18…14 AWG) Flexible cable 1 (0.5...4 mm2 / 20...10 AWG) or 2 x (0.75...2.5 mm2 / 18...14 AWG) 10 A .co.nz Motor Protective Circuit Breakers – MPW (up to 100A) 25 Motor Protective Circuit Breakers MPW25 - Coordination Tables Type “1” Coordination - Rated Conditional Short-Circuit Current Iq = 50 kA/400-415 V Direct-On-Line Starters Direct-on-line starters consist of a motor protective circuit breaker MPW25 and CWM contactor, which are already electrically and mechanically connected via the block module ECCMP. Setting overload release Rated operational power 400-415 V Rated operational current Ie (kW) (A) Ir (A) 0.06 0.21 0.09 0.31 0.12 Reference code Motor protective Circuit breaker Reference code contactors Actualing voltage (230 V 50/60 Hz) 0.16...0.25 MPW25-3-C025 CWM9-10-30D24 (230 V 50/60 Hz) 0.25...0.4 MPW25-3-D004 CWM9-10-30D24 (230 V 50/60 Hz) 0.41 0.4...0.63 MPW25-3-C063 CWM9-10-30D24 (230 V 50/60 Hz) 0.18 0.6 0.4...0.63 MPW25-3-C063 CWM9-10-30D24 (230 V 50/60 Hz) 0.25 0.8 0.63...1.0 MPW25-3-U001 CWM9-10-30D24 (230 V 50/60 Hz) 0.37 1.1 1.0...1.6 MPW25-3-D016 CWM9-10-30D24 (230 V 50/60 Hz) 0.55 1.5 1.0...1.6 MPW25-3-D016 CWM9-10-30D24 (230 V 50/60 Hz) 0.75 1.9 1.6...2.5 MPW25-3-D025 CWM9-10-30D24 (230 V 50/60 Hz) 1.1 2.6 2.5...4.0 MPW25-3-U004 CWM9-10-30D24 (230 V 50/60 Hz) 1.5 3.6 2.5...4.0 MPW25-3-U004 CWM9-10-30D24 (230 V 50/60 Hz) 2.2 5 4.0...6.3 MPW25-3-D063 CWM9-10-30D24 (230 V 50/60 Hz) 3.0 6.6 6.3...10 MPW25-3-U010 CWM9-10-30D24 (230 V 50/60 Hz) 4.0 8.5 6.3...10 MPW25-3-U010 CWM9-10-30D24 (230 V 50/60 Hz) 5.5 11.3 10...16 MPW25-3-U016 CWM12-10-30D24 (230 V 50/60 Hz) 7.5 15.2 10...16 MPW25-3-U016 CWM18-10-30D24 (230 V 50/60 Hz) 9.2 17.8 16...20 MPW25-3-U020 CWM18-10-30D24 (230 V 50/60 Hz) 11 21.7 20...25 MPW25-3-U025 CWM25-10-30D24 (230 V 50/60 Hz) 15 29.3 25...32 MPW25-3-U032 CWM32-10-30D24 (230 V 50/60 Hz) Ordering example: The type can be found in the “Rated operational power” column alongside the selected rating 2.2 kW, desired type: MPW25-3-D063 + CWM9-10-30D24 (230 V 50/60 Hz). I M 3~ 26 Motor Protective Circuit Breakers – MPW (up to 100A) www. .co.nz Type “1” Coordination - Rated Conditional Short-Circuit Current Iq = 50 kA/400-415 V Direct-On-Line Starters Direct-on-line starters consist of a motor protective circuit breaker MPW25i and CWM contactor, which are already electrically and mechanically connected via the block module ECCMP. Rated operational power 400-415 V Rated operational current Ie Operational instalaneous current Iµ (kW) (A) (A) Reference code Motor protective Circuit breaker Reference code contactors Actualing voltage (230 V 50/60 Hz) 0.06 0.21 0.25 MPW25i-3-C025 CWM9-10-30D24 (230 V 50/60 Hz) 0.09 0.31 0.4 MPW25i-3-D004 CWM9-10-30D24 (230 V 50/60 Hz) 0.12 0.41 0.63 MPW25i-3-C063 CWM9-10-30D24 (230 V 50/60 Hz) 0.18 0.6 0.63 MPW25i-3-C063 CWM9-10-30D24 (230 V 50/60 Hz) 0.25 0.8 1.0 MPW25i-3-U001 CWM9-10-30D24 (230 V 50/60 Hz) 0.37 1.1 1.6 MPW25i-3-D016 CWM9-10-30D24 (230 V 50/60 Hz) 0.55 1.5 1.6 MPW25i-3-D016 CWM9-10-30D24 (230 V 50/60 Hz) 0.75 1.9 2.5 MPW25i-3-D025 CWM9-10-30D24 (230 V 50/60 Hz) 1.1 2.6 4.0 MPW25i-3-U004 CWM9-10-30D24 (230 V 50/60 Hz) 1.5 3.6 4.0 MPW25i-3-U004 CWM9-10-30D24 (230 V 50/60 Hz) 2.2 5 6.3 MPW25i-3-D063 CWM9-10-30D24 (230 V 50/60 Hz) 3.0 6.6 10 MPW25i-3-U010 CWM9-10-30D24 (230 V 50/60 Hz) 4.0 8.5 10 MPW25i-3-U010 CWM9-10-30D24 (230 V 50/60 Hz) 5.5 11.3 16 MPW25i-3-U016 CWM12-10-30D24 (230 V 50/60 Hz) 7.5 15.2 16 MPW25i-3-U016 CWM18-10-30D24 (230 V 50/60 Hz) 9.2 17.8 20 MPW25i-3-U020 CWM18-10-30D24 (230 V 50/60 Hz) 11 21.7 25 MPW25i-3-U025 CWM25-10-30D24 (230 V 50/60 Hz) 15 29.3 32 MPW25i-3-U032 CWM32-10-30D24 (230 V 50/60 Hz) Ordering example: The type can be found in the “Rated operational power” column alongside the selected rating 2.2 kW, desired type: MPW25i-3-D063 + CWM9-10-30D24 (230 V 50/60 Hz). I M 3~ www. .co.nz Motor Protective Circuit Breakers – MPW (up to 100A) 27 Type “2” Coordination - Rated Conditional Short-Circuit Current Iq = 50/65 kA in 400-415 V Direct-On-Line Starters Direct-on-line starters consists of a motor protective circuit breaker MPW25 and CWM contactor, which are already electrically and mechanically connected via the block module ECCMP up to 32 A. Setting overload release Rated operational power 400-415 V Rated operational current Ie Reference code Motor protective Circuit breaker Iq = 50 kA Iq = 65 kA Reference code contactors Actualing voltage (230 V 50/60 Hz) Reference code contactors Actualing voltage (230 V 50/60 Hz) (kW) (A) Ir (A) 0.06 0.21 0.16...0.25 MPW25-3-C025 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz) 0.09 0.31 0.25...0.4 MPW25-3-D004 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz) 0.12 0.41 0.4...0.63 MPW25-3-C063 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz) 0.18 0.6 0.4...0.63 MPW25-3-C063 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz) 0.25 0.8 0.63...1.0 MPW25-3-U001 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz) 0.37 1.1 1.0...1.6 MPW25-3-D016 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz) 0.55 1.5 1.0...1.6 MPW25-3-D016 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz) 0.75 1.9 1.6...2.5 MPW25-3-D025 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz) 1.1 2.6 2.5...4.0 MPW25-3-U004 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz) 1.5 3.6 2.5...4.0 MPW25-3-U004 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz) 2.2 5 4.0...6.3 MPW25-3-D063 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz) 3.0 6.6 6.3...10 MPW25-3-U010 CWM9-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz) 4.0 8.5 6.3...10 MPW25-3-U010 CWM9-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz) 5.5 11.3 10...16 MPW25-3-U016 CWM12-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz) 7.5 15.2 10...16 MPW25-3-U016 CWM18-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz) 9.2 17.8 16...20 MPW25-3-U020 CWM18-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz) 11 21.7 20...25 MPW25-3-U025 CWM25-10-30D24 (230 V 50/60 Hz) CWM40-10-30D24 (230 V 50/60 Hz) 15 29.3 25...32 MPW25-3-U032 CWM50-10-30D24 (230 V 50/60 Hz) CWM50-10-30D24 (230 V 50/60 Hz) Ordering example: The type can be found in the “Rated operational power” column alongside the selected rating 2.2 kW, desired type: MPW25-3-D063 + CWM9-10-30D24 (230 V 50/60 Hz). I M 3~ 28 Motor Protective Circuit Breakers – MPW (up to 100A) www. .co.nz Type “2” Coordination - Rated Conditional Short-Circuit Current Iq = 50/65 kA in 400-415 V Direct-On-Line Starters Direct-on-line starters consists of a motor protective circuit breaker MPW25i and CWM contactor, which are already electrically and mechanically connected via the block module ECCMP up to 32 A. Rated operational power 400-415 V Rated operational current Ie Operational instalaneous current Iµ Reference code Motor protective Circuit breaker Iq = 50 kA Iq = 65 kA Reference code contactors Actualing voltage (230 V 50/60 Hz) Reference code contactors Actualing voltage (230 V 50/60 Hz) (kW) (A) (A) 0.06 0.21 0.25 MPW25i-3-C025 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz) 0.09 0.31 0.4 MPW25i-3-D004 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz) 0.12 0.41 0.63 MPW25i-3-C063 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz) 0.18 0.6 0.63 MPW25i-3-C063 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz) 0.25 0.8 1.0 MPW25i-3-U001 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz) 0.37 1.1 1.6 MPW25i-3-D016 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz) 0.55 1.5 1.6 MPW25i-3-D016 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz) 0.75 1.9 2.5 MPW25i-3-D025 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz) 1.1 2.6 4.0 MPW25i-3-U004 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz) 1.5 3.6 4.0 MPW25i-3-U004 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz) 2.2 5 6.3 MPW25i-3-D063 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz) 3.0 6.6 10 MPW25i-3-U010 CWM9-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz) 4.0 8.5 10 MPW25i-3-U010 CWM9-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz) 5.5 11.3 16 MPW25i-3-U016 CWM12-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz) 7.5 15.2 16 MPW25i-3-U016 CWM18-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz) 9.2 17.8 20 MPW25i-3-U020 CWM18-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz) 11 21.7 25 MPW25i-3-U025 CWM25-10-30D24 (230 V 50/60 Hz) CWM40-10-30D24 (230 V 50/60 Hz) 15 28.93 32 MPW25i-3-U032 CWM50-10-30D24 (230 V 50/60 Hz) CWM50-10-30D24 (230 V 50/60 Hz) Ordering example: The type can be found in the “Rated operational power” column alongside the selected rating 2.2 kW, desired type: MPW25i-3-D063 + CWM9-10-30D24 (230 V 50/60 Hz). I M 3~ www. .co.nz Motor Protective Circuit Breakers – MPW (up to 100A) 29 Motor Protective Circuit Breakers MPW - Rated Short-Circuit Breaking Capacity (IEC 60947-2)1) 2) MPW65 MPW25 MPW16 / MPW12_S Reference code MPW16 / MPW12_S / MPW25 / MPW65 220-240 V ac 380-415 V ac 440 V ac 460-500 V ac 630-690 V ac Setting overload release Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics (A) kA kA kA kA kA kA kA kA kA kA 0.10...0.16 100 100 100 100 100 100 100 100 10 10 0.16...0.25 100 100 100 100 100 100 100 100 10 10 0.25...0.4 100 100 100 100 100 100 100 100 10 10 0.4...0.63 100 100 100 100 100 100 100 100 10 10 0.63...1 100 100 100 100 100 100 100 100 10 10 1...1.6 100 100 100 100 100 100 100 100 10 10 1.6...2.5 100 100 100 100 100 100 100 100 8 8 2.5...4 100 100 100 100 100 100 100 100 8 8 4...6.3 100 100 100 100 100 100 100 100 8 8 6.3...10 100 100 50 10 50 10 10 10 5 5 5 8...12 100 100 50 10 50 10 10 10 5 10...16 3) 100 100 10 10 10 10 10 8 4 3 0.10...0.16 100 100 100 100 100 100 100 100 100 100 0.16...0.25 100 100 100 100 100 100 100 100 100 100 0.25...0.4 100 100 100 100 100 100 100 100 100 100 0.4...0.63 100 100 100 100 100 100 100 100 100 100 0.63...1 100 100 100 100 100 100 100 100 100 100 1...1.6 100 100 100 100 100 100 100 100 100 100 1.6...2.5 100 100 100 100 100 100 100 100 8 8 2.5...4 100 100 100 100 100 100 100 100 8 8 4...6.3 100 100 100 100 100 100 100 100 8 8 6.3...10 100 100 100 100 50 25 42 21 8 8 10...16 100 100 50 25 50 15 10 8 5 5 16...20 100 100 50 25 50 15 10 8 5 5 20...25 100 100 50 25 50 15 10 8 5 5 25...32 100 100 50 25 25 15 10 8 5 5 32...40 100 100 65 65 65 65 35 35 8 8 40...50 100 100 65 65 65 65 35 35 8 8 50...65 100 100 65 65 65 65 35 35 8 8 MPW100 Reference code MPW100 220-240 V ac 380-415 V ac 440-460 V ac 500-525 V ac 600-690 V ac Setting overload release Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics (A) kA kA kA kA kA kA kA kA kA kA 55...75 100 100 75 50 50 38 12 9 6 6 70...90 100 100 75 50 50 38 12 9 6 6 80...100 100 100 75 50 50 38 12 9 6 6 Note: 1) UL values on request. 2) In cases where Prospective Short-Circuit Current > Icu, back-up fuses are required. 3) MPW16 only. 30 Motor Protective Circuit Breakers – MPW (up to 100A) www. .co.nz Motor Protective Circuit Breakers MPW - Rated Short-Circuit Breaking Capacity (IEC 60947-2) - Limiter Function1) MPW25 + CLT25 Reference code MPW25 + CLT25 380-415 V ac 440 V ac 460-500 V ac 630-690 V ac Setting overload release Icu Ics Icu Ics Icu Ics Icu Ics (A) kA kA kA kA kA kA kA kA 0.10...0.16 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ 0.16...0.25 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ 0.25...0.4 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ 0.4...0.63 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ 0.63...1 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ 1...1.6 ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ 1.6...2.5 ♦ ♦ ♦ ♦ ♦ ♦ 50 50 2.5...4 ♦ ♦ ♦ ♦ ♦ ♦ 50 50 4...6.3 ♦ ♦ ♦ ♦ ♦ ♦ 50 50 6.3...10 ♦ ♦ 100 100 100 100 50 50 10...16 100 100 100 100 100 100 50 50 16...20 100 100 100 100 100 100 50 50 20...25 100 100 100 100 100 100 10 10 25...32 100 100 100 100 100 100 10 10 MPW65 + MPW65i Reference code 630-690 V ac (A) kA kA kA kA MPW65 + MPW65i3-U065 460-500 V ac Setting overload release 32...40 65 65 25 25 40...50 65 65 25 25 50...65 65 65 25 25 Icu Ics Icu Ics Note: 1) in cases where Prospective Short-Circuit Current > Icu, back-up fuses are required (see back-up fuses chart in page B-29) ♦ Not applicable due to MPW25 already having 100 kA of Icu / Ics in referred ranges. www. .co.nz Motor Protective Circuit Breakers – MPW (up to 100A) 31 Motor Protective Circuit Breakers MPW - Characteristics Curves The tripping characteristic shows the motor circuit breaker trip time in relation to the rated current. The curves show average tolerance range values for an ambient temperature of 20 °C, starting in cold state. Thermal trip time when working in operating temperature is reduced to around 25% of the presented values. Under normal operating conditions, all 3 circuit breaker phases must be conducting. MPW25t Minute Minute MPW16i/MPW12i_S/25i/65i Minute minut e MPW16/MPW12_S/25/65 Second Milisecond Second Second Millisecond 2-phase Millisecond second milisecond 3-phase X Adjusted current Ie Ratedoperational current X Adjusted current Ie Durchlasswerte I2t at 415V - MPW16/16i Characteristic I2t at 415 V - MPW16/16i X Rated operational current Characteristic I2t at 415 V - MPW25/25i 100 16 10 6,3 10 I².t I 2 .txx10³ 10 3(A².s) (A 2 .s) 4 2,5 1 1,6 1 0,1 0,63 0,01 0,4 0,25 0,16 0,001 0,1 1 10 100 Prospektiver kurzchlusstrom (kA) [RMS] Presumed short-circuit current (kA) [RMS] 32 Motor Protective Circuit Breakers – MPW (up to 100A) Presumed short-circuit current (kA) [RMS] www. .co.nz Motor Protective Circuit Breakers MPW - Tripping Characteristics Curves Durchlasswerte I2t at 415V - MPW65/65i Characteristic I2t at 415 V - MPW65/65i Short Circuit Current Limitation Curve at 400/415 V - MPW25 1000 65 40 100 Peak current (kA) I 2 .t x 10 3 (A 2 .s)I².t x 10³ (A².s) 50 10 1 0,1 1 10 100 Prospektiver kurzchlusstrom (kA) [RMS] Presumed short-circuit current (kA) [RMS] Presumed short-circuit current Ip (kA) [RMS] www. Short Circuit Limitation Curve at 500 V - MPW25 Peak current (kA) Peak current (kA) Short Circuit Current Limitation Curve at 440 V - MPW25 Presumed short-circuit current Ip (kA) [RMS] .co.nz Presumed short-circuit current Ip (kA) [RMS] Motor Protective Circuit Breakers – MPW (up to 100A) 33 Connection Diagrams and Typical Circuits Connection Diagrams ACBF-11 and ACBF 11 MPW100 ACBS-11 and ACBS-11-MPW100 ACBS-20 and ACBS-20-MPW100 ACBS-02 and ACBS-02 MPW100 TSB TSB AT11 MPW100 TSB SC-11 URMP SRMP 77 85 78 86 I> MPW25 + CLT25 Single-phase connection L1 N Two-phase connection L1 L1 L3N L1 L3 Feeder 1L1 3L2 5L3 I> I> 1L1 3L2 1L1 5L3 3L2 5L3 I> I> 2T1 4T2 6T3 Load I >I > I >I > I> 2T1 4T2 2T16T3 4T2 6T3 M ~ M ~ 1L1 3L2 5L3 I> I> I> 2T1 4T2 6T3 M ~ Typical Circuits Undervoltage release URMP Shunt release SRMP Trip signalling block TSB F1 S S0...Sn - Buttons in the plant (NC) 34 S0...Sn - Buttons in the plant (NO) S - MPW Auxiliary contact Motor Protective Circuit Breakers – MPW (up to 100A) H1 - Short-circuit trip signalling H2 - Overcurrent trip signalling www. .co.nz Motor Protective Circuit Breakers MPW - Dimensions (mm) MPW12 + Accessories 90 90 90 90 5 ∅5 1818 18 18 45 4545 45 Mounting Position 9 99 9 SRMP URMP TSB TSB TSB DIN 35mm 106 106 106 106 97 97 97 119 97 119 119 119 ACBS ACBS ACBS ACBS TSB 5 5 1818 18 18 SRMP SRMP SRMP URMP URMP URMP 360º 77 77 77 77 30 30 30 30 45 5 9 45 9 MPW16 + CIC 5 59 59 59 59 5 17 17 9 11 11 9 8.25 8.25 CIC 16A CIC 16A 17 11 14 14 14 14 14 45 14 14 48 MPW16 + CWC07...16 11 8.25 14 2.05 14 8.37 100.55 8.37 100.55 100.55 100.55 105 105 105 105 8.37 8.37 48 48 2.05 8.25 8.37 8.37 48 17 11 2.05 ∅2.05 CIC 16A CIC 16 16 CIC 16 CIC 16 11 11 8.37 14 14 14 8.37 14 14 14 Insulated Enclosure - MPE66 (IP66) 77 MPW16 MPW16i 175 83 83 150 150 165 92 92 CWC07...16 www. .co.nz 167 167 ECCMP-C016 Motor Protective Circuit Breakers – MPW (up to 100A) 35 MPW12_S + Accessories 9 45 45 9 ∅5 Ø5 Mounting Position Trilho DIN Trilho DIN 35mm mm 35 106 106 100 100 119 119 ACBF ACBF 360º 30 30 77 77 ∅4 .8 MPW25 + Accessories 90 18 45 18 DIN 35mm 105 118 URMP SRMP ACBS 97 9 TSB 98 30 MPW25 + CWC07…16 98 45 165 MPW25 MPW25i MPW25t ECCMP-C016 CWC07...16 36 Motor Protective Circuit Breakers – MPW (up to 100A) www. .co.nz MPW25 + CWC025 45 98 165 176 MPW25 MPW25i MPW25t ECCMP-C025 CWC025 MPW25 + CWM9...18 98 98 45 4.80 PLMP 183 ECCMP-25 183 193 MPW25 MPW25i MPW25t CWM9 CWM12 CWN18 10 4.50 35 MPW25 + CWM25 45 Din rail-35 mm (DIN EM50022) 30 98 4.80 PLMP 183 193 183 MPW25 MPW25i MPW25t ECCMP-25 CWM25 10 4.50 35 www. .co.nz Motor Protective Circuit Breakers – MPW (up to 100A) 37 MPW25 + CWM32 Current Limiter - CLT25 98 4. 8 45 105 118 MPW25 MPW25i MPW25t 105 ∅ 55 DIN 35mm 200 ECCMP-32 72 30 CWM32 Front Plate - FME55 63 60 38 87 105 17 40 3.8 89 85 92 30 A<5 Maximum trickness ≤ 5 Insulated Enclosure - MPE55 (IP55) Insulated Enclosure - MLPE55 (IP55) 129 109 129 109 109 155 167 157 ∅4.5 155 ∅4.5 92 M25 M25 38 M25 M25 Motor Protective Circuit Breakers – MPW (up to 100A) www. .co.nz Accessories: BBS45, BBS54, FTBBS, LST25, LST65 BBS45 BBS54 BBS45 13 LST25 20 A 14.4 FTBBS MPW25 MPW25i 118 143 MPW25 MPW25i 133.5 127.5 118 BBS54 B 133 123 45 54 40 FTBBS 98 98 25 LST25 LST25 51 25 24 40 44 28 28 Ref. code BBS45-2 BBS45-3 BBS45-4 A 85 130 175 BBS45-5 220 Ref. code BBS54-2 BBS54-3 BBS54-4 BBS54-5 B 94 149 202 256 LST65 and MPW65+PLST65 32 54 LST65 44 63 177 169 MPW 65/65i 33.6 156.63 Door Coupling Rotary Handle - RMMP 72 PLMP 18 5.5 149 .8 ∅4 28 a 302 ACBF Door panel thickness 1.0 to 5.0 mm ∅ 16 45° 118 97 12.2 MPW25 MPW25i ∅4 105 ACBS 0 SRMP URMP R2 9 RMMP Shaft (130 or 330 mm) Panel door drillings 97 6.9 177 to 451 19.4 www. .co.nz 30 Motor Protective Circuit Breakers – MPW (up to 100A) 39 Door Coupling Rotary Handle - MRX 154 154 to 276 4848to 276 48.50 48.50 24.25 24.25 97 97 48.50 48.50 24.25 24.25 AA < 5.0 5.0 mm mm MRX MRX .50 0 2.5 22 Shaft (130 (130 or Shaft or 330 330mm) mm) 202to to 430 430 202 7.20 7.20 50.70 50.70 4 4 Ø2 ∅ Ø 23,50 23.50 11.50 11.50 A A 3.20 3.20 Ø MPW25 MPW25 MPW25i MPW25i MPW25t MPW25t Drilling thedrillings panel door Panel door MPW65 + Accessories Mounting Position 99 54 4. 8 0 18 ∅ 18 125 URMP SRMP ACBS 144 9 DIN 35mm TSB 360º 30 157 Door Coupling Rotary Handle - RMMP65 213 213 28 to to 302 28 302 54 54 < 5.0mm A <A 5.0 mm MPW65 RR22 00 MPW65 MPW65i MPW65i 52,60 52,60 ∅ Ø 1166 ∅ 4 4455°° 3,50 3.50 4 125 125 Ø B B Shaft Shaft (130 or 330mm) (130 or 330 mm RMMP RMMP Panel door drillings Panel door drillings 10 10 241 to515 515 241 to 19.22 19.22 Door Coupling Rotary Handle - MRX65 48to to 276 48 276 213 213 54 54 48.50 48.50 24.25 24.25 MPW65 MPW65 MPW65i MPW65i ∅Ø 44 A <<5.0mm A 5.0 mm ØØ222 2..5 500 MRX MRX 3,20 3.20 Shaft Shaft (130 or 330mm) (130 or 330 mm 23.50 23.50 24.25 24.25 125 125 3.50 3.50 A A 48.50 48.50 33 33 Paneldoor door drillings Panel drillings 10 10 261 to to 489 261 489 40 Motor Protective Circuit Breakers – MPW (up to 100A) 50.70 50.70 www. .co.nz MPW100 , , 106.5 30mm mm mm 18 18 9 mm mm SMRP UMRP ACBS ACBS TSB AT DIN DIN RAI L 35 / mm / mm 75m m 75 mm mm mm 165 ACBS m 155mm mm DIN RAI L mm / 75m MPW SMRP SMRP UMRP UMRP TSB AT MPW le ) TSB-AT11 MPW100 TSB-SC11 MPW100 mm ho mm mm 70 mm M4 (M ou nti ng mm mm 171 Door Coupling Rotary Handle - MR MPW100 B B 4.5 mm 4,5mm 4x ∅3.4 4x Ø3,4 A < 7.6 mm A < 7,6 mm ∅43 53,6 53.6 0,9mm 0.9 mm Ø43 MR MPW100-115 MRMR MPW100-115 MPW100-315 MR MPW100-315 B (mm) Models Reference code 53.6 53,6 Drilling the panel door Drilling the door drilling B (mm) Min: 220 min: 220 MR MPW100-115 MR MPW100-115 max: 282 Max: 282 MR MPW100-315 Min: 220 MR MPW100-315 Max: 482 min: 220 max: 482 Mounting Position MRX100 30° 51 a 91 90 ° ° 48.5 24.25 <5 ∅4 48.5 24.25 28.7 0.9 ∅22.5 3.2 23.5 MPW100 90 120 ° 191 Haste (130 mm) Paneldoor door drillings Panel door Paneldrillings door drillings Panel drillings 242 a 282 4.5 www. .co.nz 50.7 Motor Protective Circuit Breakers – MPW (up to 100A) 41 Notes 42 Motor Protective Circuit Breakers – MPW (up to 100A) www. .co.nz AUCKLAND Unit 18, 761 Great South Road, Penrose, Auckland 1061, P +64 9 525 4440, F +64 9 525 4449 MATAMATA - HEAD OFFICE 2 Waihou Street, PO Box 242, Matamata 3440, P +64 7 881 9005, F +64 7 888 4317 CHRISTCHURCH 42 Hands Road, Middleton, Christchurch 8024, P +64 3 338 0000, F +64 3 338 0012 www.trind.co.nz