Tr DRIESCHER Customer specific Switches Indoor - Outdoor Disconnectors and Earthing Switches ES ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D-85366 MOOSBURG • TEL. +49 87 61 6 81-0 • FAX +49 87 61 68 12 30 http://www.driescher.com infoservice@driescher.de DRIESCHER - Special Design Content: • 2 General, operating conditions, technical description • 3 2-pole indoor earthing switch ES 24-20-2 ; (Ur 24 kV) • 4 4-pole indoor earthing switch ES 12-20-4 u. ES 24-20-4 ; (Ur 12 kV and 24 kV) • 5 3-pole indoor earthing switch ES 24-.. ; (Ur 24 kV) • 6 7-, 8- and 9-pole indoor earthing switch ES 12-20-.. ; (Ur 3,6 kV) • 7 7-pole indoor earthing device EE 3,6-5-7 ; (Ur 3,6 kV) • 8 1-pole indoor disconnector ITr 12-4000-50-1 ; (Ur 12/√3 kV) • 9 2-pole indoor disconnector ITr ..-....-..-2 ; (Ur 12 kV, 24 kV and 38,5 kV) • 10 2-pole indoor disconnector ITr ..-....-..-2 ; (Ur 12 kV, 24 kV and 38,5 kV) • 11 4-pole indoor disconnector ITr 12-4000-50-4 ; (Ur 12 kV) • 12 2-pole outdoor disconnector FTr 12-630-20-2 ; (Ur 12 kV) General The disconnectors ITr and FTr are applicable for a rated voltage of 12 kV, 24 kV, 36 kV and 38.5 kV and a rated current range from 630 A up to 4000 A. Higher rated currents on request. The rated short-time current up to 50 kA for a duration of 3 s respectively 1 s depending on the model has been tested. The described disconnectors are intended for currentless switching in medium-voltage switchgears. The earthing switches ES can be used for a rated voltage of 3.6 kV, 12 kV, 24 kV, 36 kV and 38.5 kV. Some earthing switches have a short-circuit making capacity and are specified with the electrical life E1. The electrical life E0 is specified for earthing switches without short-circuit making capycity. All switchgears are type-tested according to EN 62271-102. For each switch an instruction manual for transportation, mounting and putting into operation is enclosed. Operating Conditions The installation of the switches can be carried out at heights of up to 1000 m above sea level. At heights above 1000 m the rated insulating level of the switch has to be corrected accordingly. The switches are designed for normal operating conditions according to EN 62271-1. According to this the following limiting values apply: Ambient temperature: Peak value of the ambient temperature: +40°C Highest average value over 24 hours: +35°C Lowest ambient temperature: -25° C / - 5°C (class "minus 5 indoor”) (class "minus 25 outdoor”) Technical Description General The base frames of indoor switches are zinc-plated and chromated, of outdoor switches hot-dip galvanized. The current carrying paths are galvanic silverplated. The contacts and the contact blades are made of drawn electrolytic copper. Rustproof pressure springs maintain the required contact force over the whole mechanical life. 2 Equipments Generally, all DRIESCHER disconnectors and earthing switches are equipped with an operating shaft (Ø 30 mm) what enables the optional mounting of the actuator on the left for on the right side. The disconnectors with a rated current of 2500 A and higher, have contact elements with self lubricating coat silver-graphite on the impact side. DRIESCHER - Special Designs 2-pole Indoor Earthing Switch Type ES 24-20-2 ; (Ur 24 kV) Type Rated voltage Rated frequency Rated short-time current Rated short-circuit duration Rated peak withstand current Rated impulse withstand voltage - Phase to earth Rated power frequency withstand voltage - Phase to earth Drawing-no. Mechanical life Electrical life ES 24-20-2 Ur fr Ik tk Ip Up 24 kV 50 Hz / 60 Hz 20 kA 3s 50 kA 125 kV Ud 50 kV IT3-108087 M2 E0 Accessory: • signalling contacts • motor actuator UM 10 and 50 Drawing for ES 24-20-2 / Drawing-no IT3-108087 Part-No 2-73479050 3 DRIESCHER - Special Designs 4-pole Indoor Earthing Switch Type ES 12-20-4 and ES 24-20-4 ; (Ur 12 kV and 24 kV) Type Rated Rated Rated Rated Rated voltage frequency short-time current short-circuit duration peak withstand current Rated impulse withstand voltage - Phase to earth Rated power frequency withstand voltage - Phase to earth Drawing-no. Mechanical life Electrical life Pic.: ES 12-20-4 Accessory: • signalling contacts • motor actuator UM 10 and UM 50 Ur fr Ik tk Ip Up ES 12-20-4 ES 24-20-4 12 kV 50 Hz / 60 Hz 20 kA 3s 50 kA 24 kV 50 Hz / 60 Hz 20 kA 3s 50 kA 75 kV 125 kV Ud 28 kV IT3-105362 M2 E1 Drawing for ES 12-20-4 / Drawing no IT3-105362 278 100 238 30 600 624 111 7,3 15 140 140 140 363 140 195 25 40 Drawing for ES 24-20-4 / Drawing no IT3-108089 Part no 2-73479070 4 385 13 Part no 2-73469230 ! !# 50 kV IT3-108089 M2 E0 ! $ % !# DRIESCHER - Special Designs 3-pole Indoor Earthing Switch Type ES 24-.. ; (Ur 24 kV) Type R2 15 Rated Rated Rated Rated Rated ES 24-40 voltage frequency short-time current short-circuit duration peak withstand current Ur 24 kV 24 kV fr 50 Hz / 60 Hz 50 Hz / 60 Hz Ik 50 kA 40 kA tk 3s 3s Ip 125 kA 100 kA Up Rated impulse withstand voltage - Phase to earth Rated power frequency withstand voltage Ud - Phase to earth Drawing-no. Mechanical life Electrical life Accessory: • signalling contacts • motor actuator UM 10 ES 24-50 125 kV 125 kV 50 kV IT3-110073 M1 E0 50 kV IT3-110047 M1 E0 Drawing for ES 24-40 / Drawing no IT3-110073 ! 582,5 % & ! % ( ( ' 2-73471500 582,5 275 275 380 40 D D 15 25 140 642 105 25 2 13 40 13 45 70 14 C 12 C 70 750 ) * 774 % & Part no B R2 15 2-73471500 + B Drawing for ES 24-50 / Drawing no IT3-110047 744 744 400 400 410 100 20 50 211 40 205 105 255 699 19 1 180 13 13 ! 25 15 40 14 20 100 1050 77 1174 Part no 450 R2 15 2-73471630 100 5 DRIESCHER - Special Designs 7-, 8- and 9-pole Indoor Earthing Switch Type ES 12-20-.. ; (Ur 3,6 kV) Type Rated Rated Rated Rated Rated ES 12-20-7 Accessory: • signalling contacts • motor actuator UM 10 and UM 50 ES 12-20-9 3,6 kV 50 Hz / 60 Hz 20 kA 3s 50 kA 3,6 kV 50 Hz / 60 Hz 20 kA 3s 50 kA 40 kV 40 kV 40 kV 28 kV IT3-108145 M2 E0 28 kV IT3-108451 M2 E0 28 kV IT3-110800 M2 E0 Ur 3,6 kV fr 50 Hz / 60 Hz Ik 20 kA tk 3s Ip 50 kA Up voltage frequency short-time current short-circuit duration peak withstand current Rated impulse withstand voltage - Phase to earth Rated power frequency withstand voltage Ud - Phase to earth Drawing-no. Mechanical life Electrical life Pic.: ES 12-20-7 ES 12-20-8 Drawing for ES 12-20-7 / Drawing no IT3-108145 125 246 125 132 125 125 125 125 1000 278 1144 Part no 2-73469200 Drawing for ES 12-20-8 / Drawing no IT3-108451 125 246 278 Part no 2-73469100 6 132 125 125 125 1125 1269 125 125 125 75 25 30 25 165 50 15 156 364 195 290 385 250 75 25 30 15 156 25 50 165 558 290 195 385 125 DRIESCHER - Special Designs 7-pol. Indoor Earthing Device Type EE 3,6-5-7 ; (Ur 3,6 kV) Type Rated Rated Rated Rated EE 3,6-5-7 voltage frequency short-time current short-circuit duration Rated impulse withstand voltage - Phase to earth Rated power frequency withstand voltage - Phase to earth Drawing-no. Mechanical life Electrical life Fig.: EE 3,6-5-7 Ur fr Ik tk Up 3,6 kV 50 Hz / 60 Hz 5 kA 1s 20 kV Ud 10 kV IT3-104909 M1 E0 Drawing for EE 3,6-5-7 / Drawing no IT3-104909 # !" !" 200 30 1 60 84 199 ca.615 260 301 ca.329 552 216 216 25 230 200 100 75 100 75 13 Part no 2-73499951 430 7 DRIESCHER - Special Designs 1-pole Indoor Disconnector Type ITr 12-4000-50-1 ; (Ur 12/√3 kV) Type ITr 12-4000-50-1 Rated voltage Rated frequency Rated current Rated short-time current Rated short-circuit duration Rated peak withstand current Rated impulse withstand voltage - Phase to earth Rated power frequency withstand voltage - Phase to earth Drawing-no. Mechanical life Ur fr Ir Ik tk Ip Up 75 kV Ud Drawing for ITr 12-4000-50-1 / Drawing no IT3-104106 Part no 2-73668230 8 12/√3 kV 50 Hz / 60 Hz 4000 A 50 kA 3s 125 kA 28 kV IT3-104106 M1 Accessory: • signalling contacts • motor actuator UM 10 and UM 50 DRIESCHER - Special Designs 2-pole Indoor Disconnectors Type ITr ..-....-..-2 ; (Ur 12 kV, 24 kV and 38,5 kV) Type Rated voltage Rated frequency Rated current Rated short-time current Rated short-circuit duration Rated peak withstand current Rated impulse withstand voltage - Phase to earth Rated power frequency withstand voltage - Phase to earth Drawing-no. Mechanical life Ur fr Ir Ik tk Ip Up ITr 12-630-20-2 ITr 24-630-20-2 ITr 24-1600-31,5-2 ITr 36-2500-50-2 12 kV 50 Hz / 60 Hz 630 A 20 kA 3s 50 kA 24 kV 50 Hz / 60 Hz 630 A 20 kA 3s 50 kA 24 kV 50 Hz / 60 Hz 1600 A 31,5 kA 3s 80 kA 38,5 kV 50 Hz / 60 Hz 2500 A 50 kA 3s 125 kA 75 kV 125 kV 125 kV 180 kV 28 kV IT3-100427 M2 50 kV IT3-108084 M2 50 kV IT3-108085 M2 80 kV IT3-107875 M1 Ud Drawing for ITr 12-630-20-2 / Drawing no IT3-100427 Accessory: • signalling contacts • motor actuator UM 10 and UM 50 Part no 2-73149102 Drawing for ITr 24-630-20-2 / Drawing no IT3-108084 Part no 2-73149200 9 DRIESCHER - Special Designs 2-pole Indoor Disconnectors Type ITr ..-....-..-2 ; (Ur 12 kV, 24 kV and 38,5 kV) Drawing for ITr 24-1600-31,5-2 / Drawing no IT3-108085 Part no 2-73696110 Drawing for ITr 36-2500-50-2 / Drawing no IT3-107875 Part no 2-73697220 10 DRIESCHER - Special Designs 4-pole Indoor Disconnector Type ITr 12-4000-50-4 ; (Ur 12 kV) Type ITr 12-4000-50-4 Rated voltage Rated frequency Rated current Rated short-time current Rated short-circuit duration Rated peak withstand current Rated impulse withstand voltage - Phase to earth Rated power frequency withstand voltage - Phase to earth Drawing-no. Mechanical life Ur fr Ir Ik tk Ip Up 12 kV 50 Hz / 60 Hz 4000 A / 8000 A 50 kA 1s 125 kA 75 kV Ud Accessory: • signalling contacts • motor actuator UM 10 and UM 50 28 kV IT3-103264 M2 Drawing for ITr 12-4000-50-4 / Drawing no IT3-103264 L1 L2 L3 L4 Part no 2-73698000 11 DRIESCHER - Special Designs 2-pole Outdoor Disconnectors Type FTr 12-630-20-2 ; (Ur 12 kV) Type FTr 12-630-20-2 Rated voltage Rated frequency Rated current Rated short-time current Rated short-circuit duration Rated peak withstand current Rated impulse withstand voltage - Phase to earth Rated power frequency withstand voltage - Phase to earth Drawing-no. Mechanical life Ur fr Ir Ik tk Ip Up 12 kV 50 Hz / 60 Hz 630 A 20 kA 3s 50 kA 75 kV Ud 28 kV IT3-099005 M2 Accessory: • signalling contacts • motor actuator UM 90 Drawing for FTr 12-630-20-2 / Drawing no IT3-099005 Part no 2-73668230 Dimensions, weights , diagrams and descriptions in this brochure are non-binding. Subject to change without notice. switching • electricity • safely Printed on chlorine free bleached paper. For nature´s sake. ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D-85366 MOOSBURG • TEL. +49 87 61 6 81-0 • FAX +49 87 61 68 12 30 http://www.driescher.com infoservice@driescher.de