Fire/Alarm/Security/Communications

advertisement
Surge Protection
TM
For Business-Critical Continuity
Fire/Alarm/Security/Communications
Product Catalog
FPO
Protection Against Damage, Disruption,
and Costly Downtime of your …
Mission-Critical Equipment … Today’s advanced commercial/residential fire, alarm, security
and telecommunication systems are more sophisticated than ever before. In a nanosecond, transients can
disrupt, disable and ruin your mission-critical equipment. It’s why companies turn to Emerson Network Power
Surge Protection for their line of surge suppression and filtering products to protect sensitive equipment from
excessive maintenance costs, damage and costly downtime.
Emerson Network Power’s comprehensive portfolio includes products for Data/Signal Line Protection,
AC Power Surge Protection, and Filtering/Line Conditioning. Plus, all of our engineered power-quality solutions
are backed by a dedicated team of power-quality specialists who are available to share their applications and
integration knowledge with you. We’re here to help!
Why take chances by putting the security of your mission-critical equipment at risk? Turn to Emerson Network
Power Surge Protection products for peace of mind.
To learn more about the world’s most trusted lineup of multi stage, hybrid, solid state, power quality products,
call us toll-free at 800-288-6169, or visit our Web site at www.emersonnetworkpower.com/surge.
Table of Contents
Application
Product
CCTV SYSTEMS
Application Drawing
Zone/Loop/Data
120 VAC Heavy Duty 120 Volt AC
Plug-in Surge Protection/Active Tracking™ Filter
CCTV & Data Applications/Coax
Closed Circuit TV Protection
One- and Two-Pair Signal Line Protection
Two-Pair Signaling Circuit Protector (Modular)
CAT6/CAT5 Power Over Ethernet
Channel Rackmount
Edco™ PC642 Series
Edco™ HSP Series
Islatrol™ SP-6TVN
Edco™ CX Series
Edco™ CCTV-1
Edco™ FAS-1 and FAS-2 Series
Edco™ PHC Series
Edco™ CAT6-5POE Series
Edco™ RM-CX06-16R
2
3
4
5
6
7
7
8
9
9
FIRE ALARM
Application Drawing
Zone/Loop/Data
Two-Pair SLC Loop Protector (Modular)
Two-Line Telephone Protection (Modular)
Two-Pair Signaling Circuit Protector (Modular)
120 VAC Heavy Duty 120 Volt AC
120/240 VAC Heavy Duty (Parallel)
One- and Two-Pair Signal Line Protection
Medium Duty 120 VAC — Single Phase
Edco PC642 Series
Edco™ SLCP Series
Edco™ PC2-TEL
Edco™ PHC Series
Edco™ HSP Series
PowerSure™ EMC-240B
Edco™ FAS-1 and FAS-2 Series
PowerSure™ FAS-120AC
10
11
12
12
13
14
15
16
17
BURGLAR 12VDC
Application Drawings
One- and Two-Pair Signal Line Protection
Plug-in Surge Protection (Active Tracking™ Filter)
RJ11/RJ31X Telephone Protection
Single-Pair Medium Duty Low Voltage Zone/Horn/Strobe/Data
Two-Line Telephone Protection (Modular)
Edco™ FAS-1 and FAS-2 Series
Islatrol™ SP-6TVN
Edco™ FAS-TEL and FAS-31XT
Edco™ TER Series
Edco™ PC2-TEL
18
19
20
21
22
22
ACCESS CONTROL
Application Drawing
Electric Door Suppressor
Two-Pair Data/Signal Line Power
RJ11/RJ31X Telephone Protection
120 VAC Heavy Duty 120 Volt AC
Zone/Loop/Data
Data Circuit Protection
Edco™ EL-EDS
Edco™ 5W8-30
Edco™ FAS-TEL and FAS-31XT
Edco™ HSP Series
Edco™ PC642 Series
Edco™ LCDP
23
24
25
26
27
28
29
COMMUNICATIONS
One- and Two-Pair Signal Line Protection
DIN Rail Protection
High Frequency Coax Protector — N-Type
High Frequency Coax Protector — F-Type
Intercom/Speaker Punch Block Protection (Parallel)
Intercom/Speaker Punch Block Protection (Series)
Telecom/Punch Block Protection
Data/Signal Line/Punch Block Protection
Fits Standard 66MI-50 Punch Down Blocks
RJ11/RJ31X Telephone Protection
Multi-Channel Rackmount
Data Circuit Protection
RJ-45 Telephone/Data
Terminating Assembly
CAT6/CAT5 Power Over Ethernet
Key Systems
Edco™ FAS-1 and FAS-2 Series
Edco™ DRS (DC) Series
Edco™ CX-HFN
Edco™ CATV-DF
Edco™ OPX Series
Edco™ PB Series
Edco™ H Series
Edco™ COHP Series
Edco™ MGB Ground Rail
Edco™ FAS-TEL and FAS-31XT
Edco™ RM-CAT6-POE Series
Edco™ LCDP
Edco™ RJA-RJD Series
Edco™ TBLK Assembly
Edco™ CAT6-5POE Series
Edco™ MOD-12
30
31
32
32
33
34
35
36
36
37
38
38
39
40
40
41
™
Page #
CCTV Systems
Protecting CCTV Systems Application Drawing
SP 3
Video
Head-End
Equipment
Rack
SP 5
SP 3
SP 5
SP 6
Video
SP 4
Power
Video
SP 5
SP 4
Power
RS-485, RS-422 (PTZ)
SP 5
SP 6 Exterior Camera
with PTZ
Multiplexer
SP 7
Power Over Ethernet (POE)
SP 7
Exterior POE
Camera
SP 1
or
SP
2
AC Power
For POE with PTZ
contact Edco
Legend
SP 1 ... HSP121BT-1RU
SP 2 ... SP-6TVN
SP 3 ... CX06-M
or ...... RM-CX06-16R (16 ch.)
SP 4 ... CX06-MI
2
Exterior Fixed
Camera
SP 5 ... FAS-1-043HC (2.5A)
or ...... PHC-043* (5A)
SP 6 ... PC642C-008LC*
SP 7 ... CAT6-5 POE-FF or -MF
*Needs PCB1B Base
CCTV Systems
Edco™ PC642 Series
Zone/Loop/Data
The Edco PC642 Series surge suppressor is a two-pair (four-wire) module
implementing three-stage hybrid technology. This module addresses
over-voltage transients with gas tubes and silicon avalanche components.
In addition, sneak and fault currents are mitigated with resettable fuses (PTCs).
The PTCs increase resistance by several orders of magnitude when over-currents
exceed safe levels. A normal state resumes when over-currents are removed.
The ability to self-restore in this manner significantly increases suppressor
performance and survivability.
The Edco PC642 Series card edge module is gold plated, double sided, and is
designed to mate with the Edco PCB1B gold-plated female terminal connector.
When snapped together, the data circuits “pass thru” the protector in a serial
fashion from the four “Field Side” terminals to the four “Electronics Side”
terminals. Terminals 1 or 10 of the Edco PCB1B must be attached to BuildingApproved Ground per Edco Technical Bulletin # 2015.
EDCO PCB1B BASE SOLD SEPARATELY
OPTION:
DIN RAIL KIT AVAILABLE
ORDER PART # 11604KIT-PC
Features
General Technical Specifications
■ Three-stage hybrid protection
■ Fast response time
■ Sneak/fault current protection
■ Requires Edco PCB1B base
■ Resettable fusing — PTCs
■ Low capacitance option
■ Order PC642PTU — an invaluable
troubleshooting tool
■ Plug-in module
■ 5 year warranty
Terminal Assignments
Ordering Information
Maximum Operating Voltage 5, 12, 18, 24, 30, 36,
43, 52, 180 VDC
Clamping Voltage
8, 15, 20, 30, 36, 43,
50, 60, 200* VDC
Operating Current
0.15A
Peak Surge Current
10 kA (8 x 20 µs)
Frequency Range
0 to 20 MHz
Insertion Loss
< 0.1 dB at 20 MHz
SPD Technology
Connection Type
GDT, SAD, w/Series PTC
Terminal Block
w/Compression Lugs
Terminals Accept Up To 10 AWG
Operating Temperature
Dimensions (Inches)
-40°C to +85°C
2H x 1W x 2.5L
(PC642 + PCB1B Base)
Weight
Certification
1 oz
UL 497B
* PC642C-200 is not UL certified
Caution: The hybrid design of this product includes
series resistance. Do not place this product in service
on any signal line capable of continuously supplying
more than 150 milliamperes.
PCB1B:
Odd Terminals
Unprotected Pair 2
{
Field Side
Unprotected Pair 1
{
APPLICATION:
Even Terminals
10
9
8
7
6
5
4
3
2
1
}
RS485, RS422:
PC642
RS232:
Protected Pair 2
PC642C-020 & PCB1B
E-Net, 10 Base T:
Electronics Side 2.125" 2.4"
}
PC642C-008LC & PCB1B
RS423, Token Ring: PC642C-008LC & PCB1B
4–20 ma:
Protected Pair 1
PC642C-030LC & PCB1B
PC642C-036 & PCB1B
Keying Pin
1.0
PCB1B
Ground Terminal 1 Or 10 To Building-Approved Ground
DO NOT daisy chain grounds. NOT intended for shield
termination. Install ground in accordance with all
applicable codes.
How To Specify The Appropriate Model
PC642C Voltage Clamp
8 Volts
15 Volts
20 Volts
30 Volts
36 Volts
43 Volts
50 Volts
60 Volts
**200 Volts
0
0
0
0
0
0
0
0
2
0
1
2
3
3
4
5
6
0
8
5
0
0
6
3
0
0
0
D
X
LC
no suffix
stage 2 clamp
each line-to-ground
stage 2 clamp
line-to-line only
stage 2 clamp line-to-line
and each line to ground
low capacitance option stage
2 clamp line-to-line and each
line to ground
**Not UL Listed
3
CCTV Systems
Edco™ HSP Series
120 VAC Heavy Duty 120 Volt AC
The Edco HSP Series is an advanced three-stage hybrid, solid state powerline protector. Features such as noise filtering, common mode and normal
mode suppression, nanosecond reaction time, power line tracking, and
compression screw terminations make the Edco HSP Series an excellent
choice in commercial and industrial applications.
EDCO HSP121BT-1RU
The Edco HSP Series offers a replaceable fuse designed to remove the load
(protected equipment) from the line if the unit is either overloaded or
the internal protection fails. This feature prevents surges from entering
equipment through a failed protector not noticed by the user.
Features
■ Fast response time
■ Three-stage hybrid design
■ Failure indicator
■ Replaceable fuse
■ Power line tracking
■ 1/2" or 3/4" knockouts for nipple
conduit connectors (HSP121A)
■ Filtering
■ Polycarbonite NEMA 4X enclosure
(HSP121A)
EDCO HSP121A
General Technical Specifications
Maximum Operating Voltage
120 VAC
Clamping Voltage
325 VAC
Operating Current
15A
I-Nominal (In)
47–63 Hz
EMI Attenuation (100 kHz to 100 MHz)
SPD Technology
> 40 dB
Metal Oxide Varistors (MOVs)
w/ L-C Filter
Modes Of Protection
Light On – Normal
Light Off – Requires Service
Line-to-Neutral,
Line-to-Ground,
Neutral-to-Ground
Status Indication
Power On & MOVs functional
Connection Type
3 Position, 20A Terminal Block
w/Compression Screws
Terminals Accept Up To 14 AWG
Operating Temperature
Mounting – HSP121A
Holes 3/16" Dia.
3/4" Conduit Fitting
-40°C to +85°C
Dimensions (Inches)
HSP121BT-1RU 1.8H x 2.9W x 5.3L
HSP-121A 2.95H x 4.95W x 3L
4
Mounting – HSP121BT-1RU
Holes 3/16" Dia.
39 kA (8 x 20 µs)
Operating Frequency
Certifications
Dimensions
3 kA
Total Peak Surge Current
Weight
■ 5 year warranty
10 oz
HSP121BT-1RU
ANSI/UL1449 Third Edition, Type 4
HSP121A
ANSI/UL1449 Third Edition, Type 2
3/4" Conduit Fitting
GND
1/2" Conduit Fitting
GND
N
N
AC
AC
1/2" Conduit Fitting
CCTV Systems
Islatrol™ SP-6TVN
Plug-in Surge Protection/Active Tracking™ Filter
The Islatrol SP-6TVN is an industrial-strength surge suppression/filtering device
that plugs into a standard duplex receptacle. It features uniquely designed
repositionable outlets and protects against damaging power disturbances
traveling through your wiring into your electrical outlets.
Features
■ Plugs into standard 120V, 15A
electrical outlet
■ Perfect for tight spaces, behind furniture
and appliances
■ Total peak surge current capacity of 39 kA
■ Intelligent monitoring against improper
wiring/grounding
■ Cables for telephone, video, and
data connectors included
REPOSITIONABLE OUTLETS
■ Repositionable outlets rotate to
accommodate available space
■ 60 dB maximum high frequency
■ Operational indicator lamp
■ 5 year warranty
General Technical Specifications
ANSI/IEEE C62.41 Cat A Ringwave (6 kV, 200A, 100 kHz)
AC Power Protection
Nominal Operating Voltage
120 VAC, Single Phase
Operating Voltage Range
120 VAC +/- 10%
Operating Frequency Range
265V
Common Mode
290V
47–63 Hz
Rated Output
15A
ANSI/IEEE C62.41 Category
Category A & B
Connection Type
(6) 5-15R Receptacles and
5-15P Plug
Phase Configuration
2 Wire + Gnd
Size
7.5 x 4.75 x 1.75 (Inches)
Enclosure
High Impact Plastic
Weight
ANSI/IEEE C62.41 Cat B Ringwave (6 kV, 500A, 100 kHz)
Normal Mode
275V
Common Mode
290V
Frequency Response
Normal Mode
Common Mode
L – N, L – G, N – G
Indication of Suppression Status
40 dB Maximum, Forward/Reverse, 5 MHz to 50 MHz
Low Voltage Protection
Video 1 & 2
Phone
Network
Connection Type
Type “F”
Type RJ-11
Type RJ-45
Cables Provided
6 (2x) Type “F”
6' Ends
RJ-11 Male
6' Ends
RJ-45 Male
Ends
5 kA
(8 x 20 µs)
2 kA
(10 x 1000 µs)
3 kA
(8 x 20 µs)
Status Indicator
Response Time
< .5 ns Normal Mode
ANSI/UL 1449 Third Edition Type 3
Warranty
5 Year
Peak Surge Current
Maximum Continuous Operating Voltage (MCOV)
Line To Neutral
60 dB Maximum, Forward/Reverse, 100 kHz to 50 MHz
2.0 lbs (0.9 kgs)
Modes Of Protection
Certification
Normal Mode
130 VAC
Capacitance
Protection Level
Clamping Voltage (DC)
Peak Surge Current (8 x 20 ms)
Line To Neutral
13 kA
Line To Ground
13 kA
Neutral To Ground
13 kA
Total
39 kA
Attenuation
<12 pf
<50 pf
<70 pf
L-G
T-R, T-G, R-G
L-G (8 Lines)
145 V
270-350 V
30 V
1 dB @ 2 Ghz
N/A
N/A
5
CCTV Systems
Edco™ CX Series
CCTV & Data Applications/Coax
The Edco CX Series Surge Protective Devices (SPDs) implement three-stage
hybrid technology. The SPDs address over-voltage transients with a primary
Gas Discharge Tube (GDT), and secondary Silicon Avalanche Diode (SAD)
components. Over-current protection, e.g. sneak and fault currents, are
mitigated with solid-state resettable fuses —PTCs. The Edco CX Series SPDs
are designed in accordance with NFPA 780 (2004 edition) requirements,
with up to 20 kA of surge current capability. The Edco CX06-MI model has an
isolated ground and is recommended for use at the camera end.
OPTION:
DIN RAIL KIT AVAILABLE
ORDER PART # 11604KIT-CX
Features
■ Sneak/fault current protection
■ CX06-MI has an isolated ground
■ Low insertion loss
■ 5 year warranty
■ Shielded case
General Technical Specifications
Ordering Information
Maximum Operating Voltage
5 VDC
Connection Type
Clamping Voltage
6 VDC
Operating Temperature
0.17A
Dimensions (Inches)
Operating Current
Peak Surge Current
Frequency Range
Insertion Loss
SPD Technology
20 kA (8 x 20 µs)
0 to 20 MHz
< 1 dB at 20 MHz
GDT, SAD, w/Series PTC
Weight
Certification
BNC, 50/75 Ohms
-40°C to +85°C
M = 1.5H x 1W x 3.25L
MI = 1.5H x 1W x 4L
SBL = 1.7H x 1.4W x 2.8L
M = 2.3 oz MI = 3 oz
UL 497B
CX06-MI-SBL Installation
6
Head End
Camera End
CX06-M
CX06-MI
CX06-MI-SBL
• Other configurations available — please consult
factory
CCTV Systems
Edco™ CCTV-1
Closed Circuit TV Protection
The Edco CCTV-1 application is specifically designed for lightning protection on
closed circuit TV systems. The protector is easily installed with standard type BNC
coax connectors. The Edco CCTV-1 offers low loss, even at frequencies approaching
500 Mhz. This is important for error-free data communication applications.
Features
■ Automatic recovery
■ Shielded case
■ Low insertion loss
■ Miniature size
■ Easily installed
■ 5 year warranty
General Technical Specifications
Maximum Operating Voltage
Clamping Voltage
5 VDC
90 VDC (Spark Over Voltage)
Operating Current
Frequency Range
0 to 1 GHz
Insertion Loss
< 0.5 dB at 500 MHz
<1.0 dB at 900 MHz
1A
Peak Surge Current
10 kA (8 x 20 µs)
SPD Technology
Gas Discharge Tube (GDT)
Connection Type
BNC, 75 Ohm
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
0.6H x 0.6W x 2.0L
Weight
1 oz
Edco™ FAS-1 and FAS-2 Series
One- and Two-Pair Signal Line Protection
The Edco FAS-1 and Edco FAS-2 Series are multi-stage one-pair or two-pair surge
suppressors designed for high-exposure applications. These products were
specifically designed to meet multiple, low voltage, protection applications in the
fire and security industries.
Features
General Technical Specifications
Maximum Operating Voltage
15, 24, 36, 52 VDC
Clamping Voltage
18, 33, 43, 60 VDC
Operating Current
2.5A
0 to 10 MHz
< 0.1 dB at 10 MHz
SPD Technology
GDT, SAD, w/Series Inductor
■ 5 year warranty
Installation
Ordering Information
Unprotected Or Field Side
Ground Lug
10–14 AWG
Terminal Block
w/Compression Lugs
Terminals Accept Up To 12 AWG
Operating Temperature
Dimensions (Inches)
Certification
■ Automatic recovery
■ Multi stage protection
Line
Insertion Loss
Weight
■ Data/signal lines
10 kA (8 x 20 µs)
Frequency Range
Connection Type
■ Common mode and differential protection mode
Equip.
Peak Surge Current
■ Lightning protection for low voltage
FAS-1 = 3.5 oz
FAS-2 = 7 oz
UL 497B
12 VDC Use
FAS-1-033 HC (One-pair)
FAS-2-033 HC (Two-pair)
24 VDC Use
FAS-1-043 HC (One-pair)
FAS-2-043 HC (Two-pair)
24 VAC Use
FAS-1-060 HC (One-pair)*
FAS-2-060 HC (Two-pair)*
48V Systems Use
*Not UL listed
-40°C to +85°C
FAS-1 = 1.5H x 1.5W x 2.8L
FAS-2 = 2H x 2W x 2.8L
FAS-1-018 HC (One-pair)
FAS-2-018 HC (Two-pair)
Protected Equipment
Caution: The hybrid design of this product includes series
resistance. Do not place this product in service on any
signal line capable of continuously supplying more than
2.5 amperes.
DO NOT daisy chain grounds. NOT intended for shield
termination. Install ground in accordance with all
applicable codes.
7
CCTV Systems
Edco™ PHC Series
Two-Pair Signaling Circuit Protector (Modular)
The Edco PHC Series is designed to protect two pairs of wires specifically
for alarm and security systems where operating currents can be as high
as 5 amps. Electrically, the Edco PHC Series is a rugged series hybrid
implementing a staged complement of MOVs, copper wound inductors and
Silicon Avalanche Diodes. This design reduces series resistance to 0.2 Ohms
per pair. These products are intended to mate with an Edco PCB1B
gold-plated female terminal connector.
The Edco PHC modules plug into a base assembly (Edco PCB1B). The base
assembly can be mounted to any flat surface and should be located as close
as practical to the protected equipment. Terminal 1 and/or terminal 10
should be connected to Building-Approved Ground with 12- or 10-gauge
solid wire.
EDCO PCB1B BASE SOLD SEPARATELY
EDCO PCB1B BASE SOLD SEPARATELY
Features
■ Continuous current up to 5 Amps
■ Three-stage protection
■ UL 497B listed
■ Differential protection
■ Requires Edco PCB1B base
■ Common mode protection
■ Order PC642PTU — an invaluable
troubleshooting tool
■ Plug-in module
■ Automatic recovery
■ 5 year warranty
■ Fast response time
General Technical Specifications
Maximum Operating Voltage
Clamping Voltage
12, 18, 24, 36, 52, 70,
120 VDC
Peak Surge Current
Frequency Range
Insertion Loss
SPD Technology
Connection Type
Operating Temperature
Dimensions (Inches)
5A
10 kA (8 x 20 µs)
0 to 10 MHz
-40°C to +85°C
3.7H x 1.75W x 2.375L
(PHC + PCB1B Base)
8 oz
Certification
UL 497B
Applications Part Number
70V Speaker Lines
8
{
Field Side
Unprotected Pair 1
{
Even Terminals
10
9
8
7
6
5
4
3
2
1
< 0.1 dB at 10 MHz
Weight
24V Horn, Strobe, Bell
Unprotected Pair 2
PHC-043 & PCB1B
PHC-SP70 & PCB1B
}
Voltage Clamp
Protected Pair 2
Electronics Side 2.125" 2.4"
}
Protected Pair 1
Keying Pin
MOV, SAD, w/Series Inductor
Terminal Block
w/Compression Lugs
Terminals Accept Up To 10 AWG
How To Specify The Appropriate Model
PCB1B:
Odd Terminals
15, 20, 30, 43, 60, 100, 150 VDC
Operating Current
Ordering Information
Terminal Assignments
1.0
Ground Terminal 1 Or 10 To Building-Approved Ground
DO NOT daisy chain grounds. NOT intended for shield
termination. Install ground in accordance with all
applicable codes.
Dimensions
* Not UL listed
CCTV Systems
Edco™ CAT6-5POE Series
CAT6/CAT5 Power Over Ethernet
The Edco CAT6-5POE Series is designed to work on Category 5 Power-OverEthernet transmission lines as well as Category 6 applications. Ideal to protect
expensive equipment against surges and transients entering a building on
exposed transmission lines. Available in both female to female and male to
female RJ-45 connectors.
Features
■ Exceeds CAT5 & 6 transmission values
■ Applications up to 60 VDC @ 300 mA
■ CAT5 POE compatible
■ 1 year warranty
■ CAT6 compatible
General Technical Specifications
Maximum Operating Voltage
60 VDC
Connection Type
Clamping Voltage
65 VDC
Operating Temperature
Operating Current
300 mA
Dimensions (Inches)
Peak Surge Current
Frequency Range
Insertion Loss
60A (10 x 1000 µs)
0 to 250 MHz
RJ-45 Jacks
-40°C to +85°C
RJ-45 (Female-Female)
RJ-45 (Male-Female)
CAT6-5POE-FF
CAT6-5POE-MF
0.8H x 1.0W x 2.3L (FF)
0.8H x 1.0W x 3.0L (MF)
Weight
1 oz
< 0.1 dB at 20 MHz
SPD Technology Silicon Avalanche Diode (SAD)
Edco™ RM-CX06-16R
Channel Rackmount
The Edco RM-CX06-16R Surge Protective Device (SPD) is a 16 channel coax SPD
implementing three-stage hybrid technology. The SPD addresses over-voltage
transients with a primary Gas Discharge Tube (GDT), and secondary Silicon
Avalanche Diode (SAD) components. Over-current protection, e.g., sneak and
fault currents, are mitigated with new solid-state resettable fuses — PTCs. The
Edco RM-CX06-16R SPD is designed in accordance with NFPA 780 (2004 edition)
requirements, with up to 20 kA of surge current capability.
Features
■ Sneak/fault current protection
■ 16 channel
■ Low insertion loss
■ 1 year warranty
■ Shielded case
General Technical Specifications
Maximum Operating Voltage
5 VDC
Frequency Range
Clamping Voltage
6 VDC
Insertion Loss
0.15A
SPD Technology
Operating Current
Peak Surge Current
20 kA (8 x 20 µs)
Connection Type
0 to 100 MHz
< 0.1 dB at 20 MHz
GDT, SAD, w/Series PTC
BNC, 50/75 Ohm
Operating Temperature
Dimensions (Inches)
Weight
Certification
-40°C to +85°C
1.75H x 19W x 2.0D (1U)
3.2 lbs
UL 497B
9
Fire Alarm
Protecting Fire Alarm Systems Application Drawing
SP 4
SP 5
Fire
Alarm
Panel
SP 6
SP 7
SP 8
AC Power
10
SP 4
RS-485 Network — Exterior
Post Indicator Valve Circuit — Exterior
SP 5
SP 6
(Over 1000 feet need protection at wall penetration point)
(24 VDC
Typical)
SP 1
or
SP 2
or
SP 9
SLC Loop — Penetrating Exterior
Notification Appliance Circuit — Exterior
Printer Circuit To Guard House
(RS-232 Typical)
Legend
Telephone
Line
SP 3
SP 6 .... FAS-1-033HC
SP 1 .... FAS-120AC
SP 7 .... PHC-043*
SP 2 .... HSP-121BT1RU
SP 8 .... PC642C-020*
SP 3 .... PC2-TEL*
SP 9 .... EMC-240B
SP 4 .... SLCP-43*
SP 5 .... PC642C-008LC*
*Needs PCB1B Base
SP 7
SP 8
Fire Alarm
Edco™ PC642 Series
Zone/Loop/Data
The Edco PC642 Series surge suppressor is a two-pair (four-wire) module
implementing three-stage hybrid technology. This module addresses
over-voltage transients with gas tubes and silicon avalanche components.
In addition, sneak and fault currents are mitigated with resettable fuses
(PTCs). The PTCs increase resistance by several orders of magnitude when
over-currents exceed safe levels. A normal state resumes when over-currents
are removed. The ability to self-restore in this manner significantly increases
suppressor performance and survivability.
The Edco PC642 card edge module is gold plated, double sided, and
is designed to mate with the Edco PCB1B gold-plated female terminal
connector. When snapped together, the data circuits “pass thru” the protector
in a serial fashion from the four “Field Side” terminals to the four “Electronics
Side” terminals. Terminals 1 or 10 of the Edco PCB1B must be attached to
Building-Approved Ground per Edco Technical Bulletin # 2015.
EDCO PCB1B BASE SOLD SEPARATELY
OPTION
DIN RAIL KIT AVAILABLE
ORDER PART # 11604KIT-PC
Features
■ Three-stage hybrid protection
■ Fast response time
■ Sneak/fault current protection
■ Requires Edco PCB1B base
■ Resettable fusing — PTCs
■ Order PC642PTU — an invaluable
troubleshooting tool
■ Low capacitance option
■ Plug-in module
General Technical Specifications
Terminal Assignments
■ 5 year warranty
Ordering Information
Maximum Operating Voltage 5, 12, 18, 24, 30,
36, 43, 52, 180 VDC
APPLICATION:
Clamping Voltage
8, 15, 20, 30, 36, 43,
50, 60, 200* VDC
RS423, Token Ring: PC642C-008LC & PCB1B
Operating Current
0.15A
Peak Surge Current
RS485, RS422:
RS232:
E-Net, 10 Base T:
10 kA (8 x 20 µs)
Frequency Range
4–20 ma:
PC642C-008LC & PCB1B
PC642C-020 & PCB1B
PC642C-030LC & PCB1B
PC642C-036 & PCB1B
0 to 20 MHz
Insertion Loss
< 0.1 dB at 20 MHz
SPD Technology
GDT, SAD, w/Series PTC
Connection Type
Terminal Block
w/Compression Lugs
Terminals Accept Up To 10 AWG
Operating Temperature
Dimensions (Inches)
-40°C to +85°C
2H x 1W x 2.5L
(PC642 + PCB1B Base)
Weight
Certification
Ground Terminal 1 Or 10 To Building-Approved Ground
DO NOT daisy chain grounds. NOT intended for shield
termination. Install ground in accordance with all
applicable codes.
How To Specify The Appropriate Model
Voltage Clamp
1 oz
UL 497B
* PC642C-200 is not UL certified
Caution: The hybrid design of this product includes
series resistance. Do not place this product in service
on any signal line capable of continuously supplying
more than 150 milliamperes.
**200 Volts
**Not UL Listed
11
Fire Alarm
Edco™ SLCP Series
Two-Pair SLC Loop Protector (Modular)
The Edco SLCP Series are four-wire modules designed to protect signaling
line circuits (SLC). The device has 0 ohms of resistance and offers line-toground protection.
Features
■ Compatible with SLC circuits
■ 497B UL listed
■ Line-to-ground protection
■ Requires Edco PCB1B base
■ State-of-the-art silicon technology
■ PC642PTU (Pass Thru Unit)
available for troubleshooting
■ Over-current protection
EDCO PCB1B BASE SOLD SEPARATELY
■ 5 year warranty
General Technical Specifications
Maximum Operating Voltage
Clamping Voltage
5, 12, 18, 24, 32, 36,
48, & 52 VDC
8, 15, 20, 30, 36,
43, 50, & 60 VDC
Operating Current
1A
Peak Surge Current
Terminal Block
w/Compression Lugs
Terminals Accept Up To 10 AWG
Dimensions (Inches)
0 to 20 MHz
Insertion Loss
< 0.1 dB at 20 MHz
S L C P
Clamping
Voltage
0 0 8
8 Volts
-40°C to +85°C
0 1 5
15 Volts
2H x 1W x 2.5L
(SLCP + PCB1B Base)
0 2 0
20 Volts
0 3 0
30 Volts
0 3 6
36 Volts
0 4 3
43 Volts
0 5 0
50 Volts
0 6 0
60 Volts
Operating Temperature
250A (8 x 20 µs)
Frequency Range
SPD Technology
Ordering Information
Connection Type
Weight
1 oz
Certification
UL 497B
Silicon Avalanche Diode (SAD)
Edco™ PC2-TEL
Two-Line Telephone Protection (Modular)
The Edco PC2-TEL is a solid state, two-line telephone interface protector
module. This unit is specifically designed to protect both phone lines
required by commercial fire panels.
Features
■ Tip-to-ring protection
■ UL listed 497A
■ Tip- and ring-to-ground protection
■ Requires PCB1B base
■ Over-current protection
■ PC642PTU (Pass Thru Unit)
available for trouble shooting
■ Resettable solid state fuses — PTC
EDCO PCB1B BASE SOLD SEPARATELY
■ 5 year warranty
General Technical Specifications
Maximum Operating Voltage
250 VDC
Insertion Loss
Clamping Voltage
270 VDC
SPD Technology
Operating Current
0.15A
Peak Surge Current
Frequency Range
12
160A
(10 x 1000 T & R To Ground)
0 to 20 MHz
Connection Type
< 0.1 dB at 20 MHz
Series PTC and
Silicon Avalanche Diode (SAD)
Terminal Block
w/Compression Lugs
Terminals Accept Up To 10 AWG
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
Weight
Certifications
2H x 1W x 2.5L
(PC2TEL + PCB1B Base)
1 oz
UL 497A, CUL
Fire Alarm
Edco™ PHC Series
Two-Pair Signaling Circuit Protector (Modular)
The Edco PHC Series is designed to protect two pairs of wires specifically
for alarm and security systems where operating currents can be as high
as 5 amps. Electrically, the Edco PHC Series is a rugged series hybrid
implementing a staged complement of MOVs, copper wound inductors and
Silicon Avalanche Diodes. This design reduces series resistance to 0.2 Ohms
per pair. These products are intended to mate with an Edco PCB1B
gold-plated female terminal connector.
The Edco PHC modules plug into a base assembly (Edco PCB1B). The base
assembly can be mounted to any flat surface and should be located as close
as practical to the protected equipment. Terminal 1 and/or terminal 10
should be connected to Building-Approved Ground with 12- or 10-gauge
solid wire.
EDCO PCB1B BASE SOLD SEPARATELY
Features
General Technical Specifications
Maximum Operating Voltage
15, 20, 30, 43, 60, 100, 150 VDC
Operating Current
5A
Frequency Range
Insertion Loss
SPD Technology
Connection Type
Operating Temperature
Dimensions (Inches)
■ Continuous current up to 5 Amps
■ Differential protection
■ UL 497B listed
■ Common mode protection
■ Requires Edco PCB1B base
■ Plug-in module
■ Automatic recovery
■ Order PC642PTU — an invaluable
troubleshooting tool
■ Fast response time
■ 5 year warranty
10 kA (8 x 20 µs)
0 to 10 MHz
Unprotected Pair 2
{
Field Side
Unprotected Pair 1
{
Even Terminals
10
9
8
7
6
5
4
3
2
1
3.7H x 1.75W x 2.375L
(PHC + PCB1B Base)
Weight
8 oz
Certification
UL 497B
Voltage Clamp
P H C
}
Protected Pair 2
Electronics Side 2.125" 2.4"
}
Protected Pair 1
Keying Pin
MOV, SAD, w/Series Inductor
-40°C to +85°C
How To Specify The Appropriate Model
PCB1B:
Odd Terminals
< 0.1 dB at 10 MHz
Terminal Block
w/Compression Lugs
Terminals Accept Up To 10 AWG
Ordering Information
Terminal Assignments
12, 18, 24, 36, 52, 70,
120 VDC
Clamping Voltage
Peak Surge Current
■ Three-stage protection
1.0
Ground Terminal 1 Or 10 To Building-Approved Ground
DO NOT daisy chain grounds. NOT intended for shield
termination. Install ground in accordance with all
applicable codes.
0 1 5
15 Volts
0 2 0
20 Volts
0 3 0
30 Volts
0 4 3
43 Volts (For Horn, Bell, Strobes)
0 6 0
60 Volts
S P 7 0
*100 Volts
1 3 0 R M S
*150 Volts
(For 120V Signal Lines)
*Not UL Listed
Dimensions
Applications Part Number
24V Horn, Strobe, Bell
70V Speaker Lines
PHC-043 & PCB1B
PHC-SP70 & PCB1B
13
Fire Alarm
Edco™ HSP Series
120 VAC Heavy Duty 120 Volt AC
The Edco HSP Series is an advanced three-stage hybrid, solid state powerline protector. Features such as noise filtering, common mode and normal
mode suppression, nanosecond reaction time, power line tracking, and
compression screw terminations make the Edco HSP Series an excellent
choice in commercial and industrial applications.
EDCO HSP121BT-1RU
The Edco HSP Series offers a replaceable fuse designed to remove the load
(protected equipment) from the line if the unit is either overloaded or
the internal protection fails. This feature prevents surges from entering
equipment through a failed protector not noticed by the user.
Features
■ Fast response time
■ Three-stage hybrid design
■ Failure indicator
■ Replaceable fuse
■ Power line tracking
■ 1/2" or 3/4" knockouts for nipple
conduit connectors (HSP121A)
■ Filtering
■ Polycarbonite NEMA 4X enclosure
(HSP121A)
■ 5 year warranty
EDCO HSP121A
General Technical Specifications
Maximum Operating Voltage
120 VAC
Clamping Voltage
325 VAC
Operating Current
15A
I-Nominal (In)
3 kA
Total Peak Surge Current
47–63 Hz
EMI Attenuation (100 kHz to 100 MHz)
> 40 dB
Line-to-Neutral,
Line-to-Ground,
Neutral-to-Ground
Status Indication
Power On & MOVs functional
Connection Type
3 Position, 20A Terminal Block
w/Compression Screws
Terminals Accept Up To 14 AWG
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
HSP121BT-1RU 1.8H x 2.9W x 5.3L
HSP-121A 2.95H x 4.95W x 3L
Certifications
14
Light On – Normal
Light Off – Requires Service
Metal Oxide Varistors (MOVs)
w/ L-C Filter
Modes Of Protection
Weight
Mounting – HSP121BT-1RU
Holes 3/16" Dia.
39 kA (8 x 20 µs)
Operating Frequency
SPD Technology
Dimensions
10 oz
HSP121BT-1RU
ANSI/UL1449 Third Edition, Type 4
HSP121A
ANSI/UL1449 Third Edition, Type 2
Mounting – HSP121A
Holes 3/16" Dia.
3/4" Conduit Fitting
3/4" Conduit Fitting
GND
1/2" Conduit Fitting
GND
N
N
AC
AC
1/2" Conduit Fitting
Fire Alarm
PowerSure™ EMC-240B
120/240 VAC Heavy Duty (Parallel)
The PowerSure EMC-240B surge suppressor is designed to protect AC
distribution panel circuits or 120V power supplies feeding sensitive
electronic equipment. Electrically, the unit incorporates MOV and thermal
fusing technology. The PowerSure EMC-240B is designed to be installed in
parallel on standard single phase 120/240 VAC (3W + G) or single phase
120 VAC (2W + G) circuits.
Features
■ Fast response time
■ Operational status indicators
■ 40 kA per phase capacity
■ ANSI/UL 1449 Third Edition Type 2
■ Failsafe and fused
■ 5 year warranty
Mechanical
General Technical Specifications
Maximum Operating Voltage
120/240 VAC
I Nominal (In)
3 kA
Operating Current
2.8"
NA, Parallel
Total Peak Surge Current
2.2"
80 kA (8 x 20 µs)
Operating Frequency
47–63 Hz
EMI Attenuation (100 kHz to 100 MHz)
> 40 dB
SPD Technology
4.5"
Metal Oxide Varistors (MOVs)
Modes Of Protection
Line-to-Line Line-to-Neutral
Status Indication
Power On & MOVs Functional
Connection Type
Wire Leads
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
18"
4.6H x 2.2W x 2.8L
Weight
13.5 oz
Certification
Caution:
Installation and service should be performed by qualified electricians only.
ANSI/UL 1449 Third Edition, Type 2
Before installing EMC, remove all electrical power from circuits.
Connect on load side of main breakers. Use two dedicated 30A circuit breakers.
Installation
120/240 VAC Service
120 VAC Service
L1
L
120 V
N
EMC-240B
240 V N
L2
120 V
240 V GND
120 V
EMC-240B
Black
Black
White
Green
Ground
N
Ground
L
2.8
240 VAC Service
L1
L2
240 V
240 V
Black
Black
White
Green
L2 N
L1
EMC-240B
Black
Black
White
Green
L2 GND L1
2.2
15
Fire Alarm
Edco™ FAS-1 and FAS-2 Series
One- and Two-Pair Signal Line Protection
The Edco FAS-1 and Edco FAS-2 Series are multi stage one-pair or two-pair surge
suppressors designed for high exposure applications. These products were
specifically designed to meet multiple low voltage protection applications in the
fire and security industries.
Features
■ Lightning protection for low voltage
■ Data/signal lines
■ Common mode and differential
protection mode
■ Multi stage protection
■ Automatic recovery
■ 5 year warranty
General Technical Specifications
Maximum Operating Voltage
15, 24, 36, 52 VDC
Clamping Voltage
18, 33, 43, 60 VDC
Operating Current
2.5A
Peak Surge Current
0 to 10 MHz
Insertion Loss
< 0.1 dB at 10 MHz
Operating Temperature
Dimensions (Inches)
Certification
10–14 AWG
Line
Terminal Block
w/Compression Lugs
Terminals Accept Up To 12 AWG
FAS-1 = 3.5 oz
<3
FAS-2 = 7 oz
UL 497B
Protected Equipment
DO NOT daisy chain grounds. NOT intended for shield
termination. Install ground in accordance with all
applicable codes.
16
12VDC Use
FAS-1-033 HC (One-pair)
FAS-2-033 HC (Two-pair)
24VDC Use
FAS-1-043 HC (One-pair)
FAS-2-043 HC (Two-pair)
24VAC Use
48V Systems Use
* Not UL listed
Caution: The hybrid design of this product includes series
resistance. Do not place this product in service on any
signal line capable of continuously supplying more than
2.5 amperes.
-40°C to +85°C
FAS-1 = 1.5H x 1.5W x 2.8L
FAS-2 = 2H x 2W x 2.8L
FAS-1-018 HC (One-pair)
FAS-2-018 HC (Two-pair)
FAS-1-060 HC (One-pair)*
FAS-2-060 HC (Two-pair)*
Ground Lug
GDT, SAD, w/Series Inductor
Equip.
SPD Technology
Weight
Unprotected Or Field Side
10 kA (8 x 20 µs)
Frequency Range
Connection Type
Ordering Information
Installation
Fire Alarm
PowerSure™ FAS-120AC
Medium Duty 120 VAC — Single Phase
The PowerSure FAS-120AC surge suppressor is designed to protect AC distribution
panel circuits or 120V power supplies feeding sensitive electronic equipment.
Electrically the unit incorporates MOV and thermal fusing technology. This device is
designed to be installed in parallel on standard single phase 120 VAC
(L, N, G) circuits.
Installation can be close-nipple up to a distribution panel/circuit or hardwired in
parallel up to power supply input terminal screws. Be sure to dress leads as short
as possible.
Features
■ LED indicator
■ Compact size
■ Fast response time
■ Liquid tight conduit fitting
■ Thermal fuse
■ ANSI/UL 1449 Third Edition Type 2
■ L-G, L-N, & N-G protection
■ 5 year warranty
General Technical Specifications
Part Number
Mounting
PowerSure FAS-120AC
Maximum Operating Voltage
120 VAC
SPD Location Type
Type 2
I-Nominal (In)
3 kA
Operating Current
Peak Surge Current
2.5"
NA
6.5 kA/Mode, 13 kA/Phase, 15.5 kA/Total
Operating Frequency
EMI Attenuation
NA
SPD Technology
MOVs
Modes of Protection
L-N, L-G, N-G
Status Indication
Power On & MOVs Functional
Connection Type
Wire Leads
Operating Temperature
Dimensions (Inches)
Ø0.1860
-40°C to +85°C
2.5H x 1.5W x 3.0L
Weight
Certification
1.5"
47–63 Hz
4 oz
ANSI/UL 1449 Third Edition, Type 2
Caution:
This product should be installed and serviced by qualified service
technicians or personnel only.
3"
Remove power before installation or service.
17
Burglar 12VDC
Protecting Burglar Alarm Systems Application Drawings
Commercial
Residential
18
Burglar 12VDC
Edco™ FAS-1 and FAS-2 Series
One- and Two-Pair Signal Line Protection
The Edco FAS-1 and Edco FAS-2 Series are multi stage one-pair or two-pair surge
suppressors designed for high-exposure applications. These products were
specifically designed to meet multiple, low voltage, protection applications in the
fire and security industries.
Features
■ Common mode and differential
protection mode
■ Lightning protection for low voltage
■ Data/signal lines
■ Automatic recovery
■ Multi stage protection
General Technical Specifications
Maximum Operating Voltage
15, 24, 36, 52 VDC
Clamping Voltage
18, 33, 43, 60 VDC
Operating Current
Unprotected Or Field Side
0 to 10 MHz
Insertion Loss
< 0.1 dB at 10 MHz
GDT, SAD, w/Series Inductor
Operating Temperature
Dimensions (Inches)
-40°C to +85°C
10–14 AWG
FAS-2 = 7 oz
FAS-1-033 HC (One-pair)
FAS-2-033 HC (Two-pair)
24VDC Use
FAS-1-043 HC (One-pair)
FAS-2-043 HC (Two-pair)
24VAC Use
48V Systems Use
*Not UL listed
Caution: The hybrid design of this product includes series
resistance. Do not place this product in service on any
signal line capable of continuously supplying more than
2.5 amperes.
FAS-1 = 1.5H x 1.5W x 2.8L
FAS-2 = 2H x 2W x 2.8L
FAS-1 = 3.5 oz
12VDC Use
Line
Terminal Block
w/Compression Lugs
Terminals Accept Up To 12 AWG
FAS-1-018 HC (One-pair)
FAS-2-018 HC (Two-pair)
FAS-1-060 HC (One-pair)*
FAS-2-060 HC (Two-pair)*
Ground Lug
Equip.
SPD Technology
Certification
Ordering Information
10 kA (8 x 20 µs)
Frequency Range
Weight
Installation
2.5A
Peak Surge Current
Connection Type
■ 5 year warranty
<3
UL 497B
Protected Equipment
DO NOT daisy chain grounds. NOT intended for shield
termination. Install ground in accordance with all
applicable codes.
19
Burglar 12VDC
Islatrol™ SP-6TVN
Plug-in Surge Protection (Active Tracking™ Filter)
The Islatrol SP-6TVN is an industrial-strength surge suppression/filtering device
that plugs into a standard duplex receptacle. It features uniquely designed
repositionable outlets and protects against damaging power disturbances
traveling through your wiring into your electrical outlets.
Features
■ Plugs into standard 120V, 15A
electrical outlet
■ Perfect for tight spaces, behind furniture
and appliances
■ Total peak surge current capacity of 39 kA
■ Intelligent monitoring against improper
wiring/grounding
■ Cables for telephone, video, and
data connectors included
■ Repositionable outlets rotate to
accommodate available space
REPOSITIONABLE OUTLETS
■ 60 dB maximum high frequency
■ Operational indicator lamp
■ 5 year warranty
General Technical Specifications
ANSI/IEEE C62.41 Cat A Ringwave (6 kV, 200A, 100 kHz)
AC Power Protection
Nominal Operating Voltage
Operating Voltage Range
Operating Frequency Range
Rated Output
ANSI/IEEE C62.41 Category
Connection Type
Phase Configuration
Size
Enclosure
Weight
Modes Of Protection
Indication Of Suppression Status
Response Time
Certification
120 VAC, Single Phase
120 VAC +/- 10%
Normal Mode
265V
Common Mode
290V
47–63 Hz
15A
Category A & B
(6) 5-15R Receptacles and
5-15P Plug
2 Wire + Gnd
7.5 x 4.75 x 1.75 (Inches)
High Impact Plastic
ANSI/IEEE C62.41 Cat B Ringwave (6 kV, 500A, 100 kHz)
Normal Mode
275V
Common Mode
290V
Frequency Response
Normal Mode
Common Mode
L – N, L – G, N – G
Low Voltage Protection
Video 1 & 2
Phone
Network
< .5 ns Normal Mode
Connection Type
Type “F”
Type RJ-11
Type RJ-45
ANSI/UL 1449
Third Edition Type 3
Cables Provided
6 (2x) Type “F”
6' Ends
RJ-11 Male
6' Ends
RJ-45 Male
Ends
5 kA
(8 x 20 µs)
2 kA
(10 x 1000 µs)
3 kA
(8 x 20 µs)
Status Indicator
Peak Surge Current
130 VAC
Capacitance
Protection Level
20
40 dB Maximum, Forward/Reverse, 5 MHz to 50 MHz
2.0 lbs (0.9 kgs)
Maximum Continuous Operating Voltage (MCOV)
Line To Neutral
60 dB Maximum, Forward/Reverse, 100 kHz to 50 MHz
Peak Surge Current (8 x 20 ms)
Clamping Voltage (DC)
Line To Neutral
13 kA
Attenuation
Line To Ground
13 kA
Neutral To Ground
13 kA
Total
39 kA
<12 pf
<50 pf
<70 pf
L-G
T-R, T-G, R-G
L-G (8 Lines)
145 V
270–350 V
30 V
1 dB @ 2 Ghz
N/A
N/A
Burglar 12VDC
Edco™ FAS-TEL and FAS-31XT
RJ11/RJ31X Telephone Protection
The Edco FAS-TEL and Edco FAS-31XT are single-pair telephone or data line
protectors that implement advanced two-stage hybrid design. These units
address over-voltage transients with silicon breakover devices, while sneak and
fault currents are mitigated with PTC technology which consists of solid state
resettable fuses.
The Edco FAS-31XT replaces the RJ31X jack with a protected version. Four screw
terminals are provided to wire the protector in the same manner as a standard
RJ31X jack.
The Edco FAS-TEL is nearly identical to the Edco FAS-31XT except without the
shorting bars. Two screw terminals are provided to connect the incoming
telephone line to the protector. Protected equipment such as modems are
plugged into the female modular jack on the Edco FAS-TEL.
Features
■ <1 nanosecond response time
■ Line-to-line protection
■ Solid-state silicon breakover technology
■ Line-to-ground protection
■ Low capacitance
■ Polyswitch resettable fuses — PTCs
■ Over current protection
■ 5 year warranty
■ UL 497A listed
General Technical Specifications
Maximum Operating Voltage
12, 24, 43, 52, 180, 220,
& 220 VDC
How To Specify The Appropriate Model
F A S - T E L -
T
Clamping
Voltage
Clamping Voltage
15, 30, 50, 60, 200, 270 & 300 VDC
0.15A
0 1 5
15 Volts
Operating Current
0 3 0
30 Volts
160A
(10 x 1000 µs T & R to Ground)
0 5 0
50 Volts
0 6 0
60 Volts
2 0 0
200 Volts
Peak Surge Current
Frequency Range
0 to 20 MHz
Insertion Loss
< 0.1 dB at 20 MHz
F A S - 3 1 X T
270 Volts
SPD Technology
Silicon Avalanche Diode
w/ Series PTC
F A S - T E L - D S L
300 Volts
Connection Type
Terminal Block
w/Compression Lugs In/
RJ Connector Out
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
1H x 2W x 2L
Weight
2 oz
Certifications
UL 497A, CUL
Ordering Information
FAS-TEL-060T
Digital Phone
FAS-TEL-200T
Analog Phone/Fax/Modem
FAS-31XT
FAS-TEL-DSL
Alarm System Phone
DSL
21
Burglar 12VDC
Edco™ TER Series
Single-Pair Medium Duty Low Voltage
Zone/Horn/Strobe/Data
The Edco TER surge suppressor directly installs onto electronic circuit wiring
terminal screws. This close proximity preserves Edco TER’s response time,
clamping level and ground reference by eliminating lead lengths. The Edco
TER’s miniature size fits directly inside fire or security panels, CCTV housings
and other system electronic enclosures. These features maximize surge
suppression performance while reducing hardware and labor costs to install.
Features
■ Fits Euro style and barrier strip terminals
■ UL 497B listed
■ Automatic recovery
■ Operating current > 2 Amps
■ Single-pair protection
■ Compact size: 1.3" x 0.4" x 2" (HxWxL)
■ High energy silicon avalanche technology
■ 5 year warranty
General Technical Specifications Ordering Information
Maximum Operating Voltage
15, 30, 40 VDC
Clamping Voltage
18, 33, 43 VDC
Operating Current
0.09A
Peak Surge Current (10 x 1000 µs)
018 = 215A,
033 = 108A,
043 = 81A
Frequency Range
0 to 20 MHz
Insertion Loss
Zone, Buss, Loop, Data, Receive, Bell, Horn, Strobe,
Pan/Tilt & CCTV
TER-018 (For 12 VDC Systems)
TER-033 (For 24 VDC Systems)
TER-043 (For 24 VDC Systems)
<0.1 dB at 20 MHz
SPD Technology
Connection Type
Fits In Series With Circuits Wires At The
Terminal Screws
Silicon Avalanche Diode (SAD)
Terminal Block
w/Compression Lugs
Terminals Accept Up To 12 AWG
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
1.3H x 0.4W x 2.0L
Weight
0.6 oz
Certification
UL 497B
Edco™ PC2-TEL
Two-Line Telephone Protection (Modular)
The Edco PC2-TEL is a solid state, two-line telephone interface protector
module. This unit is specifically designed to protect both phone lines required by
commercial security panels.
Features
■ Tip-to-ring protection
■ UL listed 497A
■ Tip- and ring-to-ground protection
■ Requires PCB1B base
■ Over-current protection
■ PC642PTU (Pass Thru Unit)
available for troubleshooting
■ Resettable solid state fuses — PTCs
EDCO PCB1B BASE SOLD SEPARATELY
■ 5 year warranty
General Technical Specifications
Maximum Operating Voltage
250 VDC
Insertion Loss
Clamping Voltage
270 VDC
SPD Technology
Operating Current
0.15A
Peak Surge Current
Frequency Range
22
160A
(10 x 1000 T & R To Ground)
0 to 20 MHz
Connection Type
< 0.1 dB at 20 MHz
Series PTC and
Silicon Avalanche Diode (SAD)
Terminal Block
w/Compression Lugs
Terminals Accept Up To 10 AWG
Operating Temperature
Dimensions (Inches)
Weight
Certifications
-40°C to +85°C
2H x 1W x 2.5L
(PC2TEL + PCB1B Base)
1 oz
UL 497A, CUL
Access Control
Protecting Access Control Systems Application Drawing
SP 1
Door Lock
Power Supply
SP 2
Dial-Up
Com
SP 8
SP 7
Access
Control
Panel
SP 3
SP 4
SP 5
To Head-End or
Other
Control Panels
RS-485/RS-422 Circuit
Electric Strike or
Maglock Circuit
SP 2
SP 3
Card Reader (Wiegand)
SP 4
Circuit for Device Outside of Building
LAN/
WAN
AC Power
SP 1
SP 5
SP 6
Gate Position Switch
Gate Lock/Control
Legend
SP 1 .... HSP-121BT1RU
SP 2 .... PC642C-008LC*
SP 3 .... EL-EDS
SP 4 .... 5W8-30*
SP 5 .... FAS-1-xxxHC
SP 6 .... FAS-2-xxxHC
SP 7 .... LCDP-xxx
SP 8 .... FAS-31XT
*Needs PCB1B Base
23
Access Control
Edco™ EL-EDS
Electric Door Suppressor
The Edco EL-EDS suppressor kit is intended for installation with electrical
switching devices that are connected through a relay contact on typical access
control panels.
The Edco EL-EDS protects against electrical anomalies (transients) that are
generated as a result of the collapsing electrical field of an electromagnetic
switching device (maglock or electric strike). The Edco EL-EDS provides
protection for both relay contacts and control panel.
Features
■ <1 Electromagnetic protection
■ 2 devices per package
■ Relay contact and control panel protection
■ 5 year warranty
General Technical Specifications
Installation
Maximum Operating Voltage
52 VDC
Clamping Voltage
56 VDC
The diagram below illustrates the proper installation of the Edco
EL-EDS. For each maglock or electric strike circuit, you will need to
install a suppressor (1) across the relay contacts and (2) across the
leads connected to the lock solenoid (locate as close as possible to
the solenoid). The suppressor wires can be installed without regard
to polarity. If your package does not contain two (2) devices, contact
your distributor.
Operating Current
Peak Surge Current
Frequency Range
Insertion Loss
SPD Technology
Connection Type
Operating Temperature
Dimensions (Inches)
Weight
Warranty
24
NA
500 A
0 to 20 MHz
<0.1 dB at 20 MHz
SAD w/Filtering Capacitor
Wire Leads
-40˚C 10 +85˚C
8L
1 oz
5 years
Access Control
Edco™ 5W8-30
Two-Pair Data/Signal Line Power
The Edco 5W8-30 is an access control protection module designed for
typical Wiegand outputs for access devices. This is a 5-wire module that
accommodates low voltage data lines for 5 VDC circuits. Fifth wire power
protection will allow up to 24 VDC.
In addition, sneak and fault currents are mitigated with resettable fuses
(PTCs). The PTCs increase resistance several orders of magnitude when overcurrents exceed safe levels. A normal state resumes when over-currents are
removed. The ability to self restore in this manner significantly increases
suppressor performance and survivability.
EDCO PCB1B BASE SOLD SEPARATELY
Features
■ Automatic recovery
■ Silicon avalanche technology
■ Fast response time
■ Requires Edco PCB1B base
■ Resettable fusing — PTCs
■ Plug-in module
■ PC462 PTU (Pass Thru Unit)
available for troubleshooting
■ Data and power protection combined
■ 5 year warranty
■ Sneak/fault current protection (data only)
Note: The hybrid design of this product includes series resistance. Do not use this device if data pairs are
capable of continuously supplying more than 150 milliamperes.
General Technical Specifications
Maximum Operating Voltage
5 VDC (Data) &
24 VDC (Power)
Clamping Voltage
8 VDC (Data) & 30 VDC (Power)
Operating Current
0.15A
Peak Surge Current
Frequency Range
Insertion Loss
SPD Technology
Connection Type
Operating Temperature
Dimensions (Inches)
Weight
Installation
DC Power — T-Tap Positive
Common Wire Here
Data = 125A (10 x 1000 µs)
Power = 500 A (8 x 20 µs)
0 to 20 MHz
< 0.15dB at 20 MHz
MOV, SAD, w/ Series PTC
Terminal Block
w/compression Lugs
Terminals Accept Up To 10 AWG
-40°C to +85°C
2H x 1W x 2.5L
(5W8-30 + PCB1B Base)
1 oz
Ground Terminal To Building-Approved Ground (Preferably AC Power Safety Ground)
DO NOT daisy chain grounds. NOT intended for
shield termination. Install ground in accordance
with all applicable codes.
25
Access Control
Edco™ FAS-TEL and FAS-31XT
RJ11/RJ31X Telephone Protection
The Edco FAS-TEL and Edco FAS-31XT are single-pair telephone or data line
protectors that implement advanced two-stage hybrid design. These units
address over-voltage transients with silicon breakover devices, while sneak and
fault currents are mitigated with PTC technology which consists of solid state
resettable fuses.
The Edco FAS-31XT replaces the RJ31X jack with a protected version. Four screw
terminals are provided to wire the protector in the same manner as a standard
RJ31X jack.
The Edco FAS-TEL is nearly identical to the Edco FAS-31XT except without the
shorting bars. Two screw terminals are provided to connect the incoming
telephone line to the protector. Protected equipment such as modems are
plugged into the female modular jack on the Edco FAS-TEL.
Features
■ <1 nanosecond response time
■ Line-to-line protection
■ Solid-state silicon breakover technology
■ Line-to-ground protection
■ Low capacitance
■ Polyswitch resettable fuses — PTCs
■ Over current protection
■ 5 year warranty
■ UL 497A listed
General Technical Specifications
Maximum Operating Voltage
12, 24, 43, 52, 180, 220,
& 220 VDC
Clamping Voltage
15, 30, 50, 60, 200, 270 & 300 VDC
Operating Current
0.15A
Peak Surge Current
0 to 20 MHz
Insertion Loss
< 0.1 dB at 20 MHz
SPD Technology
Silicon Avalanche Diode
w/ Series PTC
Connection Type
Terminal Block
w/Compression Lugs In/
RJ Connector Out
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
1H x 2W x 2L
Weight
2 oz
Certifications
UL 497A, CUL
Ordering Information
FAS-TEL-060T
Digital Phone
FAS-TEL-200T
Analog Phone/Fax/Modem
FAS-TEL-DSL
26
F A S - T E L -
160A
(10 x 1000 µs T & R to Ground)
Frequency Range
FAS-31XT
How To Specify The Appropriate Model
Alarm System Phone
DSL
T
Clamping
Voltage
0 1 5
15 Volts
0 3 0
30 Volts
0 5 0
50 Volts
0 6 0
60 Volts
2 0 0
200 Volts
F A S - 3 1 X T
270 Volts
F A S - T E L - D S L
300 Volts
Access Control
Edco™ HSP Series
120 VAC Heavy Duty 120 Volt AC
The Edco HSP Series is an advanced three-stage hybrid, solid state, powerline protector. Features such as noise filtering, common mode and normal
mode suppression, nanosecond reaction time, power line tracking, and
compression screw terminations make the Edco HSP Series an excellent
choice in commercial and industrial applications.
EDCO HSP121BT-1RU
The Edco HSP Series offers a replaceable fuse designed to remove the load
(protected equipment) from the line if the unit is either overloaded or
the internal protection fails. This feature prevents surges from entering
equipment through a failed protector not noticed by the user.
Features
■ Fast response time
■ Three-stage hybrid design
■ Failure indicator
■ Replaceable fuse
■ Power line tracking
■ 1/2" or 3/4" knockouts for nipple
conduit connectors (HSP121A)
■ Filtering
■ Polycarbonite NEMA 4X enclosure
(HSP121A)
EDCO HSP121A
General Technical Specifications
Maximum Operating Voltage
120 VAC
Clamping Voltage
325 VAC
Operating Current
15A
I-Nominal (In)
3 kA
Total Peak Surge Current
> 40 dB
Light On – Normal
Light Off – Requires Ser vice
Metal Oxide Varistors (MOVs)
w/ L-C Filter
Modes Of Protection
Line-to-Neutral,
Line-to-Ground,
Neutral-to-Ground
Status Indication
Power On & MOVs functional
Connection Type
3 Position, 20A Terminal Block
w/Compression Screws
Terminals Accept Up To 14 AWG
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
HSP121BT-1RU 1.8H x 2.9W x 5.3L
HSP-121A 2.95H x 4.95W x 3L
Certifications
Mounting – HSP121BT-1RU
Holes 3/16" Dia.
47–63 Hz
EMI Attenuation (100 kHz to 100 MHz)
Weight
Dimensions
39 kA (8 x 20 µs)
Operating Frequency
SPD Technology
■ 5 year warranty
Mounting – HSP121A
Holes 3/16" Dia.
3/4" Conduit Fitting
3/4" Conduit Fitting
GND
1/2" Conduit Fitting
GND
N
N
AC
AC
1/2" Conduit Fitting
10 oz
HSP121BT-1RU
ANSI/UL1449 Third Edition, Type 4
HSP121A
ANSI/UL1449 Third Edition, Type 2
27
Access Control
Edco™ PC642 Series
Zone/Loop/Data
The Edco PC642 Series surge suppressor is a two-pair (four-wire) module
implementing three-stage hybrid technology. This module addresses
over-voltage transients with gas tubes and silicon avalanche components.
In addition, sneak and fault currents are mitigated with resettable fuses (PTCs).
The PTCs increase resistance by several orders of magnitude when over-currents
exceed safe levels. A normal state resumes when over-currents are removed.
The ability to self-restore in this manner significantly increases suppressor
performance and survivability.
The Edco PC642 Series card edge module is gold plated, double sided, and is
designed to mate with the Edco PCB1B gold-plated female terminal connector.
When snapped together, the data circuits “pass thru” the protector in a serial
fashion from the four “Field Side” terminals to the four “Electronics Side”
terminals. Terminals 1 or 10 of the Edco PCB1B must be attached to BuildingApproved Ground per Edco Technical Bulletin # 2015.
EDCO PCB1B BASE SOLD SEPARATELY
OPTION:
DIN RAIL KIT AVAILABLE
ORDER PART # 11604KIT-PC
Features
General Technical Specifications
■ Three-stage hybrid protection
■ Fast response time
■ Sneak/fault current protection
■ Requires Edco PCB1B base
■ Resettable fusing — PTCs
■ Low capacitance option
■ Order PC642PTU — an invaluable
troubleshooting tool
■ Plug-in module
■ 5 year warranty
Terminal Assignments
Ordering Information
Maximum Operating Voltage 5, 12, 18, 24, 30, 36,
43, 52, 180 VDC
Clamping Voltage
8, 15, 20, 30, 36, 43,
50, 60, 200* VDC
Operating Current
0.15A
Peak Surge Current
10 kA (8 x 20 µs)
Frequency Range
0 to 20 MHz
Insertion Loss
< 0.1 dB at 20 MHz
SPD Technology
Connection Type
GDT, SAD, w/Series PTC
Terminal Block
w/Compression Lugs
Terminals Accept Up To 10 AWG
Operating Temperature
Dimensions (Inches)
-40°C to +85°C
2H x 1W x 2.5L
(PC642 + PCB1B Base)
Weight
Certification
1 oz
UL 497B
* PC642C-200 is not UL certified
Caution: The hybrid design of this product includes
series resistance. Do not place this product in service
on any signal line capable of supplying more than
150 milliamperes continuously.
28
PCB1B:
Odd Terminals
Unprotected Pair 2
{
Field Side
Unprotected Pair 1
{
APPLICATION:
Even Terminals
10
9
8
7
6
5
4
3
2
1
}
RS485, RS422:
PC642
RS232:
Protected Pair 2
PC642C-020 & PCB1B
E-Net, 10 Base T:
Electronics Side 2.125" 2.4"
}
PC642C-008LC & PCB1B
RS423, Token Ring: PC642C-008LC & PCB1B
4–20 ma:
Protected Pair 1
PC642C-030LC & PCB1B
PC642C-036 & PCB1B
Keying Pin
1.0
PCB1B
Ground Terminal 1 Or 10 To Building-Approved Ground
DO NOT daisy chain grounds. NOT intended for shield
termination. Install ground in accordance with all
applicable codes.
How To Specify The Appropriate Model
PC642C Voltage Clamp
8 Volts
15 Volts
20 Volts
30 Volts
36 Volts
43 Volts
50 Volts
60 Volts
**200 Volts
**Not UL Listed
0
0
0
0
0
0
0
0
2
0
1
2
3
3
4
5
6
0
8
5
0
0
6
3
0
0
0
D
X
LC
no suffix
stage 2 clamp
each line-to-ground
stage 2 clamp
line-to-line only
stage 2 clamp line-to-line
and each line to ground
low capacitance option stage
2 clamp line-to-line and each
line to ground
Access Control
Edco™ LCDP
Data Circuit Protection
The Edco LCDP Series is designed to conveniently protect 8 wire, low voltage, data
circuits and employs two RJ-45 jacks for easy installation. The Edco LCDP utilizes
silicon avalanche (solid-state) suppression technology and exhibits very low
capacitance to accommodate high data rates. This unit supports high-speed data
rates of over 100 Mbps.
Features
■ <1 nanosecond response time
■ Silicon avalanche design
■ Line-to-line protection
■ Line-to-ground protection
■ Low capacitance
■ 5 year warranty
■ RJ-45/4 pair protection (8 wire)
General Technical Specifications
Installation
Maximum Operating Voltage
5, 12, 24, 48, 65 VDC
Clamping Voltage
8, 15, 30, 60, 75 VDC
Operating Current
Peak Surge Current (10 x 1000 µs)
Frequency Range
Insertion Loss
SPD Technology
Connection Type
Operating Temperature
Dimensions (Inches)
Weight
Certification
* LCDP-POE is not UL certified
1.5A
008 = 125A, 015 = 72A,
030 = 22A, 060 = 18A, POE*=15A
0 to 100 MHz
The user equipment plugs into the LCDP’s equipment (protected) side,
and the LCDP’s line (unprotected) side is connected to the incoming line.
All 8 conductors are protected. The green ground wire must be bonded
to the protected equipment power ground (third wire, green wire safety
ground). Do not add length to the ground wire, since it must be kept as
short as possible.
< 0.1 dB at 50 MHz
Silicon Avalanche Diode (SAD)
RJ-45 Jacks
-40°C to +85°C
1.0H x 2.5W x 4.25L
Ordering Information
Model
Clamping Voltage
3 oz
LCDP-008
8 Volts
UL 497B
LCDP-015
15 Volts
LCDP-030
30 Volts
LCDP-060
60 Volts
LCDP-POE*
75 Volts
29
Communications
Edco™ FAS-1 and FAS-2 Series
One- and Two-Pair Signal Line Protection
The Edco FAS-1 and Edco FAS-2 Series are multi stage one-pair or two-pair surge
suppressors designed for high-exposure applications. These products were
specifically designed to meet multiple, low voltage, protection applications in the
fire and security industries.
Features
General Technical Specifications
Maximum Operating Voltage
15, 24, 36, 52 VDC
Clamping Voltage
18, 33, 43, 60 VDC
Operating Current
2.5A
Peak Surge Current
■ Automatic recovery
■ Multi stage protection
■ 5 year warranty
Installation
Ordering Information
Unprotected Or Field Side
< 0.1 dB at 10 MHz
GDT, SAD, w/Series Inductor
Operating Temperature
Dimensions (Inches)
10–14 AWG
Line
Terminal Block
w/Compression Lugs
Terminals Accept Up To 12 AWG
FAS-1 = 3.5 oz
<3
FAS-2 = 7 oz
UL 497B
Protected Equipment
DO NOT daisy chain grounds. NOT intended for
shield termination. Install ground in accordance
with all applicable codes.
30
12VDC Use
FAS-1-033 HC (One-pair)
FAS-2-033 HC (Two-pair)
24VDC Use
FAS-1-043 HC (One-pair)
FAS-2-043 HC (Two-pair)
24VAC Use
48V Systems Use
*Not UL listed
Caution: The hybrid design of this product includes series
resistance. Do not place this product in service on any
signal line capable of continuously supplying more than
2.5 amperes.
-40 C to +85 C
FAS-1 = 1.5H x 1.5W x 2.8L
FAS-2 = 2H x 2W x 2.8L
FAS-1-018 HC (One-pair)
FAS-2-018 HC (Two-pair)
FAS-1-060 HC (One-pair)*
FAS-2-060 HC (Two-pair)*
Ground Lug
Equip.
SPD Technology
Certification
■ Data/signal lines
0 to 10 MHz
Insertion Loss
Weight
■ Common mode and differential protection mode
10 kA (8 x 20 µs)
Frequency Range
Connection Type
■ Lightning protection for low voltage
Communications
Edco™ DRS (DC) Series
DIN Rail Protection
The Edco DRS (DC) Series is a DIN rail mountable, single-pair surge suppression
module implementing three-stage hybrid technology. This module addresses
over-voltage transients with gas tubes and silicon avalanche components. In
addition, sneak currents are mitigated with resettable fuses (PTCs). The PTCs
increase resistance several orders of magnitude when over-currents exceed safe
levels. A normal state resumes when over-currents are removed. The ability
to self-restore in this manner significantly increases suppressor performance
and survivability.
The Edco DRS (DC) Series mounts onto a standard 35 mm industrial DIN rail.
There are three “Field Side” and three “Electronics Side” screw terminals. One
is reserved for a shield. Three electrically tied ground terminals are provided for
grounding the Edco DRS (DC) Series unit to Building-Approved Ground. Shield is
isolated from ground.
For a 2-terminal version without a shield, order the Edco DRS-XXX-2.
Features
■ Low-voltage data surge protection
■ Easy installation
■ Three-stage hybrid protection
■ Fits standard 35 mm DIN rail
■ Sneak/fault current protection with
resettable fuses—PTCs
■ Fast response time < 1 nanosecond
■ 5 year warranty
■ Low profile packaging
■ UL 497B listed
General Technical Specifications
Part
Number
Maximum
Peak Signal
Voltage
Nominal
Breakdown
Voltage
Surge
1p 10 x 1000 µs
Current
Dimensional Diagrams
Peak Current
8 x 20 µs
Waveform
Typ
Cap
(pf)
Maximum
Continuous
Current (ma)
Nominal
Series
Resistance
DRS-008
6
8
>100
10 kA
1500
150
5 Ohms
DRS-015
12
15
>100
10 kA
1500
150
5 Ohms
DRS-232
15
22
>100
10 kA
1500
150
5 Ohms
DRS-030
24
30
>100
10 kA
1500
150
5 Ohms
DRS-036
30
36
>100
10 kA
1500
150
5 Ohms
DRS-043
35
43
>100
10 kA
1500
150
5 Ohms
DRS-050
43
50
>100
10 kA
1500
150
5 Ohms
DRS-060
52
60
>100
10 kA
1500
150
5 Ohms
*DRS-175
200
250
>10
8 kA
1500
150
5 Ohms
**DRS-130
170
200
>10
8 kA
1500
5000
None
DRS-XXX
*Not UL 4978 Listed
**Warning!! DRS-130RMS is for discrete signal use only. Do not use DRS-130RMS on 120 VAC power lines. This unit is a nonhybrid, MOV design, rated above 5A operational current and can withstand greater than eight occurrences of a 10 kA
(8 x 20 µs) waveform, and greater than 1,000 occurrences of a 200A 10 x 1000 µs waveform.
DRS-XXX-2
(2 Terminal Version)
31
Communications
Edco™ CX-HFN
High Frequency Coax Protector — N-Type
The Edco CX-HFN surge protectors are designed to protect sensitive
electronic equipment from damage due to excessive voltage or currents
generated by lightning or static buildup.
The Edco CX-HFN offers low signal loss at frequencies up to 3 gigahertz.
The Edco CX-HFN accommodates both bulkhead mount and stud mount.
The input and output connections are interchangeable.
General Technical Specifications
Maximum Operating Voltage
130 VDC
Clamping Voltage
150 VDC
(DC Spark Over Voltage)
Operating Current
1A
Peak Surge Current
Frequency Range
Insertion Loss
10 kA (8 x 20 µs)
SPD Technology
Connection Type
Operating Temperature
Dimensions (Inches)
Gas Discharge Tube (GDT)
Female N-Type
Ordering Information
CX-HFN-FM
CX-HFN-FF
Female to Male
Female to Female
-40°C to +85°C
1.25H x .875W x 2.5L
Weight
4 oz
0 to 4 GHz
< 0.5 dB 2 to 3 GHz
Edco™ CATV-DF
High Frequency Coax Protector — F-Type
The Edco CATV–DF surge protectors are designed to protect sensitive electronic
equipment from damage due to excessive voltage or currents generated by
lightning or static buildup.
Applications include direct broadcast satellite systems, HDTV, and cable modems.
The Edco CATV–DF offers low signal loss at frequencies up to 2 gigahertz.
Incorporates GDT (gas discharge tube) technology.
Features
■ Automatic recovery
■ Easily installed
■ Low insertion loss
■ 5 year warranty
■ Shielded case
General Technical Specifications
Maximum Operating Voltage
150 VDC
(Spark Over Voltage)
Operating Current
1A
Peak Surge Current
32
25 VDC
Clamping Voltage
10 kA (8 x 20 µs)
Frequency Range
Insertion Loss
SPD Technology
Connection Type
0 to 2 GHz
< 1.0 dB at 1 GHz
< 2.0 dB at 2 GHz
Gas Discharge Tube (GDT)
Type F Female
Operating Temperature
Dimensions (Inches)
Weight
-40°C to +85°C
1.25H x 2.5W x 4L
3 oz
Communications
Edco™ OPX Series
Intercom/Speaker Punch Block Protection (Parallel)
Medium Exposure Applications
The Edco OPX Series surge protectors are specifically designed for mediumexposure applications. Thus, the protectors can be used on pairs inside a building
or leaving the building, in conduit up to 500 feet. These protectors are intended
to be used in conjunction with the Edco MGB Ground Rail and a standard MI-50
Punch Down Block.
The Edco OPX Series offers several, distinct advantages over other current
technologies. Among the advantages are low cost, no series resistance, and
durable solid-state construction.
Features
General Technical Specifications
■ Over-current protection
■ Utilizes MGB grounding rail
■ Replaces bridging clips on MI-50 block
■ Test point accessible
■ UL 497B listed
■ 5 year warranty
Installation
Maximum Operating Voltage 12, 24, 42, 12, 35 VDC
Clamping Voltage
15, 30, 48, 15, 56 VDC
Operating Current
2A
Test Points
Peak Surge Current
015 =125A,
(10 x 1000 µs)
030 = 71A, 048 = 45A,
CLN = 125A, SPK = 500A, 8 x 20 µs
Frequency Range
0 to 20 MHz
Insertion loss
< 0.1 dB at 20 MHz
SPD Technology
Silicon Avalanche Diode (SAD),
OPX-SPK Model Uses MOV
Connection Type
Clip
Operating Temperature
Dimensions (Inches)
-40°C to +85°C
1.25H x 0.375W x 2.0L
Weight
1 oz
Certification
UL 497B
How To Specify The Appropriate Model
O P X
MI-50 Block
DO NOT daisy chain grounds. NOT intended for shield termination.
Install ground in accordance with all applicable codes.
Clamping
Voltage
0 1 5
15 Volts
0 3 0
30 Volts
0 4 8
48 Volts
C L N
15 Volts (Call-In Circuit)
S P K
56 Volts (Speaker Circuit)
33
Communications
Edco™ PB Series
Intercom/Speaker Punch Block Protection (Series)
The Edco PB modules are solid-state protectors for intercom extension pairs.
As a new alternative to the “OPX,” the standard EDCO intercom protector, the PB
adds fusing and a new component layout. These hybrid protectors are intended
to be used in conjunction with the EDCO MGB ground rail and a standard MI-50
punch down block. The PB modules feature solid-state resettable fuses (PTCs)
between the protected equipment and the over voltage clamping components.
This unique design prevents problems with “All-Call” in the event of catastrophic
protector failure.
Features
Patented Technology
General Technical Specifications
Maximum Operating Voltage
12, 56 VDC
Clamping Voltage
21, 70 VDC
Operating Current
0.15A
Peak Surge Current
Insertion Loss
■ 5 year warranty
Installation
Test Points
0 to 20 MHz
< 0.1 dB at 20 MHz
Clip
Operating Temperature
MI-50 Block
-40°C to +85°C
1.25H x 0.4W x 2.8L
Weight
Certification
1 oz
UL 497B
Ordering Information
34
■ Test point accessible
■ UL 497B listed
PBCLN = SAD w/Series PTC,
PBSPK = MOV w/Series PTC
Connection Type
Dimensions (Inches)
■ Utilizes MGB grounding rail
■ Replaces bridging clips on M1-50 bock
PBCLN = 0.2 kA,
PBSPK = 0.5 kA (10 x 1000 µs)
Frequency Range
SPD Technology
■ Over current protection
PBCLN
Call-In Circuit
PBSPK
Speaker Circuit
See Technical Bulletin # 2017
TTA-2: Test Point Plug Available
Caution: The hybrid design of this product includes series
resistance. Do not place this product in service on any
signal line capable of continuously supplying more than
150 mA.
DO NOT daisy chain grounds. NOT intended for
shield termination. Install ground in accordance
with all applicable codes.
Communications
Edco™ H Series
Telecom/Punch Block Protection
Advanced Ultra High Speed Technology
The Edco H Series modules are ultra high speed, fused, solid state, secondary
protectors for KEY/PABX systems. The units are available in three different
clamping voltages. The Edco H Series is constructed with solid state silicon
foldback technology, polyswitch resettable fuses — PTCs — and failure fuses.
These protection modules are intended to be used in conjunction with proper
primary protectors (UL 497A). The protective elements switch from the normal
high-impedance state to a low-impedance state upon a detection of a surge,
then switch back to high impedance after the surge has passed. The Edco
H Series single-pair modules fit onto a standard Edco MI-50 split block and
replace bridging clips. In addition, these modules require the Edco MGB Ground
Rail for each Edco MI-50 block used.
Patented Technology
General Technical Specifications
Maximum Operating Voltage
50, 180, 230 VDC
Clamping Voltage
65, 200, 270 VDC
Operating Current
0.15A
Peak Surge Current
160A
(10 x 1000 µs T & R to Ground)
Frequency Range
Insertion Loss
SPD Technology
0 to 20 MHz
< 0.1 dB at 20 MHz
Silicon Breakover Device
w/Series PTC
Connection Type
Clip
Operating Temperature
Dimensions (Inches)
MI-50 Block
-40°C to +85°C
1.25H x 0.4W x 2.8L
Weight
1 oz
Certifications
UL 497A, CUL
Ordering Information
HCO
Installation
Central Office/Trunk
HAE
Analog Extension
HDE
Digital Extensions
Unprotected Side — Terminate Field Side Wiring Coming Into
Building On The “Unprotected Side”
DO NOT daisy chain grounds. NOT intended for shield termination.
Install ground in accordance with all applicable codes.
35
Communications
Edco™ COHP Series
Data/Signal Line/Punch Block Protection
High-Exposure Applications
The Edco COHP modules are three-stage hybrid protectors for low-voltage data and
telecommunications applications. The modules address over-voltage transients with
gas tubes and silicon avalanche components. In addition, sneak and fault currents
are mitigated with resettable fuses (PTCs). Intended to be used on pairs without
the presence of ringing voltage. The Edco COHP modules are designed for data and
control applications as an isolated loop circuit protector.
Features
■ Replaces bridging clips on MI-50 Block
■ Rugged, three electrode, gas tube, first stage
■ <1 nanosecond response time
■ Silicon avalanche hybrid technology
■ Line-to-line protection
■ Polyswitch resettable fusing — PTCs
■ Line-to-ground protection
■ 5 year warranty
■ Utilizes MGB grounding rail
General Technical Specifications
Maximum Operating Voltage
6, 12, 20, 24,
43, 52 VDC
Clamping Voltage
Operating Current
Peak Surge Current
Frequency Range
Insertion Loss
8, 15, 20, 30, 50, 60 VDC
0.15A
10 kA (8 x 20 µs)
0 to 20 MHz
Ordering Information
SPD Technology
GDT, SAD, w/ Series PTC
Connection Type
Operating Temperature
Dimensions (Inches)
Clamping Voltage
COHP-008
8 Volts
-40°C to +85°C
COHP-015
15 Volts
1.25H x 0.4W x 2.8L
COHP-020
20 Volts
1 oz
COHP-030
30 Volts
UL 497B
COHP-050
50 Volts
COHP-060
60 Volts
Weight
Certification
Model
Clip
< 0.1 dB at 20 MHz
Edco™ MGB Ground Rail
Fits Standard 66MI-50 Punch Down Blocks
Split Block Variations
The Edco MGB Ground Rail — designed to fit standard 66MI-50 Punch Down Blocks.
Allows Edco’s H Series, COHP, OPX, PB Series and other similar surge suppressors to
access ground when snapped onto the 66MI-50 Punch Down Block. The Standard
66MI-50 Block is capable of accommodating up to 25 Edco surge suppressors.
Protected
Unprotected
U.S. Patent No. 4,703,983
MI-50 Block
DO NOT daisy chain grounds.
NOT intended for shield termination.
Install ground in accordance with all
applicable codes.
Edco Recommends
A 10AWG Wire To
Building-Approved Ground —
Keep Short
36
Communications
Edco™ FAS-TEL and FAS-31XT
RJ11/RJ31X Telephone Protection
The Edco FAS-TEL and Edco FAS-31XT are single-pair telephone or data line
protectors that implement advanced two-stage hybrid design. These units
address over-voltage transients with silicon breakover devices, while sneak
and fault currents are mitigated with PTC technology which consists of solid state
resettable fuses.
The Edco FAS-31XT replaces the RJ31X jack with a protected version. Four screw
terminals are provided to wire the protector in the same manner as a
standard RJ31X jack.
The Edco FAS-TEL is nearly identical to the Edco FAS-31XT except without the
shorting bars. Two screw terminals are provided to connect the incoming
telephone line to the protector. Protected equipment such as modems are
plugged into the female modular jack on the Edco FAS-TEL.
Features
■ <1 nanosecond response time
■ Line-to-line protection
■ Solid-state silicon breakover technology
■ Line-to-ground protection
■ Low capacitance
■ Polyswitch resettable fuses — PTCs
■ Over current protection
■ 5 year warranty
■ UL 497A listed
General Technical Specifications
Maximum Operating Voltage
12, 24, 43, 52, 180, 220,
& 220 VDC
How To Specify The Appropriate Model
F A S - T E L -
T
Clamping
Voltage
Clamping Voltage
15, 30, 50, 60, 200, 270 & 300 VDC
0 1 5
15 Volts
Operating Current
0.15A
0 3 0
30 Volts
160A
(10 x 1000 µs T & R to Ground)
0 5 0
50 Volts
0 6 0
60 Volts
0 to 20 MHz
2 0 0
200 Volts
Peak Surge Current
Frequency Range
Insertion Loss
< 0.1 dB at 20 MHz
F A S - 3 1 X T
270 Volts
SPD Technology
Silicon Avalanche Diode
w/ Series PTC
F A S - T E L - D S L
300 Volts
Connection Type
Terminal Block
w/Compression Lugs In/
RJ Connector Out
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
1H x 2W x 2L
Weight
2 oz
Certifications
UL 497A, CUL
Ordering Information
FAS-TEL-060T
Digital Phone
FAS-TEL-200T
Analog Phone/Fax/Modem
FAS-31XT
FAS-TEL-DSL
Alarm System Phone
DSL
37
Communications
Edco™ RM-CAT6-POE Series
Multi-Channel Rackmount
The Edco RM-CAT6-POE Series is a modular, high speed, data-line protector
that utilizes a three-stage hybrid design technology. This unit addresses highenergy voltage transients that can damage expensive computer equipment.
Ideal for network switches and hubs, the Edco RM-CAT6-POE Series is easily
mounted in close proximity to the protected equipment.
MODEL SHOWN 48 CAT6-POE
Features
■ Exceeds Category 6 transmission values
■ Offered in 16 or 48 channel protection*
■ Compact 1U rack size
■ Three-stage hybrid
■ Replaceable surge modules
■ Meets POE requirements
■ Low insertion loss
■ 1 year warranty
*Other configurations available. Consult factory.
General Technical Specifications
Maximum Operating Voltage
57 VDC
VSWR
Clamping Voltage
68 VDC
Operating Humidity
Frequency Range
0-250 MHz
Operating Current
0.15A
SPD Technology
GDT, SAD, W/Series PTC
Modes of Protection
Signal High-Low
Signal High-Ground,
Signal Low-Ground
Peak Surge Current
10 kA (8 x 20 µs)
Insertion Loss
<0.1dB
<1.2
0-95% Non-Condensing
Operating Temperature
-40°C to +85°C
Input Connection Type
RJ-45
Output Connection Type
RJ-45
Mounting
Rackmount
Enclosure Type
Painted Steel
Dimensions
1.75Hx19Wx6.3D
Weight
5.5 lbs.
Edco™ LCDP
Data Circuit Protection
The Edco LCDP Series is designed to conveniently protect 8 wire, low-voltage data
circuits and employs two RJ-45 jacks for easy installation. The Edco LCDP utilizes silicon
avalanche (solid-state) suppression technology and exhibits very low capacitance
to accommodate high data rates. This unit supports high-speed data rates of over
100 Mbps.
Features
■ <1 nanosecond response time
■ Silicon avalanche design
■ Line-to-line protection
■ Line-to-ground protection
■ Low capacitance
■ 5 year warranty
■ RJ-45/4 pair protection (8 wire)
General Technical Specifications
5, 12, 24, 48, 65 VDC
Clamping Voltage
8, 15, 30, 60, 75 VDC
Operating Current
Peak Surge Current (10 x 1000 µs)
Frequency Range
Insertion Loss
SPD Technology
Connection Type
Operating Temperature
Dimensions (Inches)
Weight
Certification
38
Installation
Maximum Operating Voltage
1.5A
008 = 125A, 015 = 72A,
030 = 22A, 060 = 18A, POE*=15A
0 to 100 MHz
< 0.1 dB at 50 MHz
Silicon Avalanche Diode (SAD)
The user equipment plugs into the LCDP’s equipment (protected) side,
and the LCDP’s line (unprotected) side is connected to the incoming line.
All 8 conductors are protected. The green ground wire must be bonded
to the protected equipment power ground (third wire, green wire safety
ground). Do not add length to the ground wire, since it must be kept as
short as possible.
Ordering Information
RJ-45 Jacks
LCDP-008
8 Volts
-40°C to +85°C
LCDP-015
15 Volts
1.0H x 2.5W x 4.25L
LCDP-030
30 Volts
3 oz
LCDP-060
60 Volts
UL 497B (*except LCDP-POE)
LCDP-POE
75 Volts
Communications
Edco™ RJA-RJD Series
RJ-45 Telephone/Data
The Edco RJA and Edco RJD Series are four-pair telephone/data-line protectors
that implement advanced, two stage, hybrid design. These units address
over voltage transients with silicon breakover devices, while sneak and fault
currents are mitigated with PTC technology, which consists of solid state
resettable fuses.
The Edco RJA and Edco RJD Series incorporate Edco RJ-45 female jacks in and
out. The Edco RJA voltage clamp is set for C.O. Trunks and analog telephone
extensions (with ring in voltage), and the Edco RJD voltage clamp is set for
digital extensions (no ring in voltage).
Features
■ <1 nanosecond response time
■ Tip- and ring-to-ground protection
■ Solid-state resettable fuses — PTCs
■ CAN/CSA C22.2, No. 226-92 compliant
■ Silicon breakover technology
■ UL 497A listed
■ Low capacitance
■ 4 pair protection
■ Line-to-line protection
■ 5 year warranty
General Technical Specifications Installation
Ordering Information
Maximum Operating Voltage
48, 220 VDC
Analog Phone
RJA-45
Clamping Voltage
55, 280 VDC
Digital Phone
RJD-45
Operating Current
Peak Surge Current
Frequency Range
Insertion Loss
SPD Technology
Connection Type
Operating Temperature
Dimensions (Inches)
Weight
Certifications
0.15A
200 A (10 x 1000 µs)
0 to 50 MHz
< 0.1 dB at 50 MHz
Silicon Breakover
Devices w/Series PTC
Gnd.
RJ-45 Jacks
-40°C to +85°C
1.0H x 2.5W x 4.25L
3 oz
UL 497A, CUL
BuildingApproved
Ground
The Edco RJA and Edco RJD Series are intended for indoor use only and shall be
employed on the equipment side of a listed primary telephone protector.
39
Communications
Edco™ TBLK Assembly
Terminating Assembly
The Edco TBLK is a high-density assembly designed to house up to 12 or 25
individual Edco surge protection modules. Standard Edco H Series, COHP,
OPX, PB Series, and other similar modules (separately ordered) are suitable
for the Edco TBLK assembly. The Edco TBLK is capable of terminating solid or
stranded 26 to 14 AWG wire using compression terminal screws.
Dimensions
DO NOT daisy chain grounds. NOT intended for
shield termination. Install ground in accordance
with all applicable codes.
Edco™ CAT6-5POE Series
CAT6/CAT5 Power Over Ethernet
The Edco CAT6-5POE Series is designed to work on Category 5 Power-OverEthernet transmission lines as well as Category 6 applications. Ideal to protect
expensive equipment against surges and transients entering a building on
exposed transmission lines. Available in both female to female and male to
female RJ-45 connectors.
Features
■ Exceeds CAT5 & 6 transmission values
■ Applications up to 60 VDC @ 300 mA
■ CAT5 POE compatible
■ 1 year warranty
■ CAT6 compatible
Ordering Information
General Technical Specifications
Operating Voltage
60 VDC
Connection Type
Clamping Voltage
65 VDC
Operating Temperature
Operating Current
300 mA
Dimensions (Inches)
Peak Surge Current
Frequency Range
Insertion Loss
60A (10 x 1000 µs)
0 to 250 MHz
< 0.1 dB at 20 MHz
SPD Technology Silicon Avalanche Diode (SAD)
40
Weight
RJ-45 Jacks
-40°C to +85°C
0.8H x 1.0W x 2.3L (FF)
0.8H x 1.0W x 3.0L (MF)
1 oz
RJ-45 (FF)
CAT6-5POE-FF
RJ-45 (MF)
CAT6-5POE-MF
Communications
Edco™ MOD-12
Key Systems
The Edco MOD-12 Tip/Ring protection for Key/PBX Systems. This innovative
design creates an automatic ground window, thus eliminating the problem of
ground potential difference.
Edco H Series Protector Modules readily snap onto the Edco MOD-12. Protection
is expandable from 1 to 12 pairs in single-pair increments and is field upgradable.
In addition, test points are provided on each pair.
Features
■ 1 to 12 pair expansion
■ Protective transparent cover
■ Replaceable single-pair protection modules
■ UL 1363 listed
■ Punch down block (66 type)
■ 5 year warranty
■ Test points
AC Protection Options
1. Basic internal surge protection (standard)
2. Plug-in hybrid surge protection
Application Diagram
HCO
(One Per CO TRUNK)
HAE or HDE
(One Per Extension)
Existing Telco Primary
Protection Demarc
66 Block
Tip/Ring Or Data Protection
1. Incoming C.O. lines use HCO
2. Analog extensions use HAE
3. Digital extensions use HDE
KSU
HAE
CO TRUNKS
HDE
MOD-12
MGB Ground Rail
Ordering Information
MOD-12
Base Assembly
Chassis
Ground
Cable Shield Ground
To AC Building-Approved Ground
DO NOT daisy chain grounds. NOT intended for shield
termination. Install ground in accordance with all
applicable codes.
41
Headquarters
Surge Protection
100 Emerson Parkway
Binghamton, NY 13905
T: 607-721-8840
T: 800-288-6169
F: 607-722-8713
E: contactsurge@emerson.com
Emerson Network Power.
The global leader in enabling Business-Critical ContinuityTM.
EmersonNetworkPower.com/surge
AC Power
Connectivity
Embedded Computing
Embedded Power
Outside Plant
Power Switching & Controls
Racks and Integrated Cabinets
Services
DC Power
Monitoring
Precision Cooling
Surge Protection
Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co.
© 2010 Emerson Electric Co.
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for
damages resulting from use of this information or for any errors or omissions.
SL-50200 Rev.1 8/10 Printed in USA
Download