Surge Protection TM For Business-Critical Continuity Transportation/Traffic Signaling Surge Protection Product Catalog Keeping Power Clean And Green Power Protection To Keep Traffic Flowing Smoothly … Think about the challenge of navigating rush-hour traffic, even on a good day. Then imagine the havoc and congestion that power surges, spikes, noise and transients can create, turning your commute into a nightmare. When traffic signaling equipment goes down, it creates a ripple effect. Even when you’re up and running again, the unfortunate effects can resonate for hours after an occurrence. For more than 35 years, Edco surge protection products have been protecting equipment against these potentially catastrophic occurrences. Whether it’s highway lighting, traffic signals, controller cabinets, cameras, or sophisticated intelligent systems, rest assured that Emerson Network Power Edco products deliver the missioncritical protection you need to keep all your sensitive equipment operating as expected. Emerson Network Power Surge Protection manufactures power quality solutions in the following categories: Transient Voltage Surge Suppressors (TVSS) • Limit high-voltage spikes to an acceptable level Filtering/Line Conditioning • Protect against low-energy transients and high frequency noise Data/Signal Line Protection • Guard sensitive instrumentation against what we refer to as “backdoor” transients and noise. Why put your equipment at risk? Turn to Emerson Network Power Surge Protection products for peace of mind. We provide solutions for all your application needs and the foundation for Business-Critical Continuity™. We are committed to providing quality products, competitive pricing and reliable customer care. If you have any product application or pricing questions, please call us at 800-648-4076. We look forward to hearing from you. We’re here to help! Table of Contents Products Page # AC POWER — SERIES CONNECTED Edco ACP-340 — 120 VAC — 1 Phase 2 Edco ACP-340LED/540LED —120 VAC — 1 Phase/240 VAC — 1 Phase 3 Edco SHA-1210 —120 VAC — 1 Phase 4 Edco SHP300-10/SHP400-10 —120 VAC — 1 Phase/240 VAC — 1 Phase 5 Edco SHA-1250 — 120 VAC — 1 Phase — Modular 6 Edco HSP121BT-1RU — 120 VAC Heavy Duty (Series) Hardwire 7 ® Islatrol — SP-6TVN — Industrial Strength Surge Suppression (Series) ® Islatrol — RM Series — 120 VAC Rackmount 8 9 Edco SHA-1230FS — 120 VAC — 1 Phase — 30A FingerSafe 10 Edco SHA-1260 — 120 VAC — 1 Phase — 60A 11 ® Islatrol INXT120NL000-1 — AC Power Line Filter 12 AC POWER — PARALLEL CONNECTED PowerSure® EMC-240B — 120/240 VAC Heavy Duty 13 ® PowerSure FAS-120AC — Medium Duty 120 VAC — 1 Phase 14 Edco SPA-300 — Medium Duty 120 VAC — 1 Phase 15 Edco SPA-100T — AC Service Protection 16 Edco SHA-1201 — 120 VAC — 1 Phase 17 ® PowerSure DRS Series 18 LOW VOLTAGE DC POWER Edco FAS-1 and FAS-2 Series — One and Two Pair Signal Line Protector (Commercial) 19 Edco PHC Series — Two-Pair Signaling Circuit Protector (Modular) 20 INPUT FILES/LOOP DETECTION Edco SRA6LC Series — Vehicle Loop Detection 21 Edco SRA16C-1 — Vehicle Loop Detection 22 Edco MRA-6LC-6 — Vehicle Loop Detection 22 OUTPUT FILES Edco SPA-303 — 120 VAC Load Relay 23 Edco MPA-303 Series — Modular Output File Protector 23 COMMUNICATION LINES Edco PC642 Series — Zone/Loop/Data 24 Edco SRA64 Series — 1 Pair Data/Signal 25 VIDEO Edco SPA-60B — 120 VAC Interconnect Signal 26 Edco CX Series — CCTV Applications/Coax 27 MODEM Edco FAS-TEL-DOT — RJ Connection Telephone Protection for Traffic Cabinets 27 DATA/SIGNAL LINE Edco RJA-RJD Series — RJ-45 Telephone/Data 28 HIGHWAY LIGHTING Edco SHA Series — Highway Lightning Protection 29 AC Power — Series Connected Edco ACP-340 120 VAC — 1 Phase The Edco ACP-340 filtering surge protector absorbs power line noise and switching transients that other suppressors and RFI filters pass through. The Edco ACP-340 can replace the RFI filter when high attenuation of noise above 25 MHz is not required. If random time-base, memory loss, or other problems are affecting some of your intersections, this state-of-the-art protector can be of great benefit when properly installed. Features ■ Multi-stage hybrid design ■ Incorporates series choke ■ Industry-leading noise filtering ■ 5 year warranty ■ Nanosecond response time General Technical Specifications Installation Part Number Edco ACP-340 Operating Voltage 120 VAC Clamping Voltage 395 VAC Operating Current 10A Peak Surge Current 32.5 kA/Mode, 39 kA/Phase Operating Frequency 120 / VAC Input 47-63 Hz EMI Attenuation 60 dB typ SPD Technology MOVs w/L-C Filter Modes of Protection L-N, L-G, N-G Status Indication NA Connection Type 1/4-20 Stainless Steel Stud Operating Temperature Main Line Edco ACP-340 Main Neutral Gnd Earth Site variable (option) Earth Line Out Neutral Out Protected Power Source (to controller and other sensitive electronics) -40°C to +85°C Dimensions (Inches) 2.375H x 3.125W x 7.125L Weight 1 lb 13.5 oz Certifications ISO 9001:2000 Mounting Caution: 1. This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specification. Appropriate precautions should be exercised. 2. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only. HOLE (6 places) 3/16" dia. 1.28" PLATE 3.125" 1.28" 6.65" 7.125" 2 Cabinet Power AC Hot Bus AC Power — Series Connected Edco ACP-340LED/540LED 120 VAC — 1 Phase/240 VAC — 1 Phase The Edco ACP-340LED is an upgrade to the popular Edco ACP-340, adding a failure indicator as well as remote sensing circuitry. In addition, this unit offers much better lightning protection than the standard Edco ACP-340. The Edco ACP-340LED/540LED filtering surge protectors absorb power line noise and switching transients that other suppressors and RFI filters pass through. They can replace the RFI filter when high attenuation of noise above 25 MHz is not required. The Edco ACP-340LED/540LED utilize Thermally-protected Metal Oxide Varistors (TMOVs) with an integrated thermally activated element designed to open in the event of overheating due to the abnormal over-voltage, limited current conditions. Features ■ 50 kA/Mode & 100 kA/Phase surge current protection ■ Power On and failure LED ■ Thermally-protected Metal Oxide Varistors (TMOVs) ■ 5 year warranty Installation General Technical Specifications Part Number ■ Remote sensing circuitry Edco ACP-340LED/540LED Operating Voltage 120 VAC/240 VAC Clamping Voltage 395 VAC/775 VAC Operating Current Cabinet Power AC Hot Bus 15A Peak Surge Current 50 kA/Mode, 100 kA/Phase Operating Frequency 47-63 Hz EMI Attenuation 40 dB typ SPD Technology MOVs w/L-C Filter Modes of Protection L-N, L-G, N-G Status Indication Power On & MOVs functional Connection Type 1/4-20 Stainless Steel Stud Operating Temperature 120 / VAC Input Main Line Main Neutral Edco ACP-LED Series Neutral Out Gnd Earth Site variable (option) Earth Line Out NC C NO To remote indication if needed Protected Power Source (to controller and other sensitive electronics) -40°C to +85°C Dimensions (Inches) 1.875H x 3.25W x 5.75L Weight 1 lb Certifications ISO 9001:2000 Mounting Hole (4 places) 3/16" dia. PLATE Caution: 1. This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specification. Appropriate precautions should be exercised. 2. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only. 2.25" 3.25" Option DIN Rail Kit Available. Order Part # 11604KIT 5.25" 5.75" 3 AC Power — Series Connected Edco SHA-1210 120 VAC — 1 Phase The Edco SHA-1210 filtering surge protector absorbs power line noise and switching transients that other suppressors and RFI filters pass through. The Edco SHA-1210 can replace the RFI filter when high attenuation of noise above 25 MHz is not required. If random time-base, memory loss, or other problems are affecting some of your intersections, this state-of-the-art protector can be of great benefit when properly installed. Features ■ Multi-stage hybrid design ■ Incorporates series choke ■ 60 dB maximum noise filtering ■ 5 year warranty ■ Nanosecond response time Installation General Technical Specifications Part Number Edco SHA-1210 Operating Voltage 120 VAC Clamping Voltage 395 VAC Operating Current 10A Neutral Buss 120 VAC Input Edco SHA-1210 32.5 kA/Mode, 52 kA/Phase, 84.5 kA/Total Main Operating Frequency 47-63 Hz CB EMI Attenuation 60 dB typ SPD Technology MOVs w/L-C Filter Modes of Protection L-N, L-G, N-G Status Indication NA Connection Type 1/4-20 Stainless Steel Stud Operating Temperature AC Out AC In Protected Power Source (to controller and other sensitive electronics) Site Variable (Option) Earth AC Hot Buss Cabinet Power -40°C to +85°C Dimensions (Inches) 2.375H x 3.125W x 7.125L Weight 2 lbs Certifications ISO 9001:2000 Caution: 1. This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specification. Appropriate precautions should be exercised. 2. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only. Mounting HOLE (6 places) 3/16" dia. 1.28" PLATE 3.125" 1.28" 6.65" 7.125" 4 Neutral Out Earth Equipment Side Peak Surge Current Main Neutral AC Power — Series Connected Edco SHP300-10/SHP400-10 120 VAC — 1 Phase/240 VAC — 1 Phase The Edco SHP Series hybrid design exhibits performance levels unobtainable with simple “shunt type” protectors. The two active clamp stages, large inductor and shunt capacitance effectively halt high rate-of-rise surge waveforms, thus preventing initial voltage overshoot. Flexibility of installation is another design feature of the Edco SHP Series. The protector's first and second stages are electrically separate (line side) for use in jurisdictions that require a line filter between stages. In addition, the first stage provides protection from MAIN NEUTRAL to GND as well as MAIN LINE to GND. This is an often overlooked feature which becomes significant in locales where NEUTRAL must be kept separate from earth ground inside the cabinet. Features ■ Multi-stage hybrid design ■ Incorporates series choke ■ Nanosecond response time ■ 5 year warranty ■ Blocks high energy surges Installation General Technical Specifications Part Number Edco SHP300-10/SHP400-10 Operating Voltage 120 VAC/240 VAC Clamping Voltage 395 VAC/650 VAC Operating Current 10A Peak Surge Current Connection If Line Filter Is NOT Used CB Main Line 32.5 kA/Mode, 39 kA/Phase, 65 kA/Total Operating Frequency 47-63 Hz EMI Attenuation 40 dB typ SPD Technology MOVs w/L-C Filter Modes of Protection L-N, L-G, N-G Status Indication Cabinet Power AC Hot Line Filter (Optional) Line In 120 VAC Input Main Neutral 1/4-20 & 10-32 Stainless Steel Stud Operating Temperature Line Out Neutral Out } Neutral Buss NA Connection Type Edco SHP Series Earth Ground Earth Ground Protected Power Service (to controller and other sensitive electronics) -40°C to +85°C Dimensions (Inches) 1.8H x 2.875W x 5.3L Weight 1 lb Certifications ISO 9001:2000 Caution: 1. This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specification. Appropriate precautions should be exercised. 2. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only. Mounting 3/16" dia. (6 places) 1.17" 2.875" 1.17" 4.85" 5.30" 5 AC Power — Series Connected Edco SHA-1250 120 VAC — 1 Phase — Modular The Edco SHA-1250 is an upgraded version of the Edco SHA-1210. The Edco SHA-1250 also incorporates two LEDs for failure indication in a modular package (Utilizes 12 pin Beau connector). The hardwire terminal base (Edco SHA-1250BASE-A, ordered separately) accommodates all wiring and the protection module is designed for easy replacement. The footprint of the Edco SHA-1250-BASE-A is the same as the Edco ACP-340 and Edco SHA-1210. This makes retrofitting older cabinets easy because internal wire lengths do not have to be adjusted. The Edco SHA-1250 offers remote sensing circuitry output that is a dry relay contact closure suitable to interface with a modem or computer port for polling remotely. With this feature, a central computer could detect a failed Edco SHA-1250 and SHA-1250-BASE-A (Sold Separately) SHA-1250 at the intersection. The Edco SHA-1250 provides excellent noise suppression over a large frequency range. Typical noise attenuation is 10 dB @ 10 KHz, 50 dB @ 100 KHz and 90 dB @ 1 MHz. Features ■ Plug-in module ■ Remote-sensing circuitry ■ LED indication ■ 5 year warranty ■ Filtering General Technical Specifications Part Number Edco SHA-1250 Operating Voltage 120 VAC Clamping Voltage 340 VAC Operating Current 15A Peak Surge Current Operating Frequency 47-63 Hz EMI Attenuation 50 dB typ SPD Technology MOVs w/L-C Filter Status Indication Power On & MOVs functional 1/4-20 SS Stud Base, Plug-in Module Operating Operating Temperature Dimensions (Inches, Module +Base) Certifications 1.28" PLATE 3.125" 1.28" 6.65" 7.125" L-N, L-G, N-G Connection Type Weight (Module + Base) HOLE (6 places) 3/16" dia. 26 kA/Mode, 32.5 kA/Phase, 45.5 kA/Total Modes of Protection 6 Mounting -40°C to +85°C 3.5H x 3.125W x 7.125L 1 lb 11.5 oz ISO 9001:2000 Caution: 1. This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specification. Appropriate precautions should be exercised. 2. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only. AC Power — Series Connected Edco HSP121BT-1RU 120 VAC Heavy Duty (Series) Hardwire The Edco HSP121BT-1RU is an advanced 3-stage hybrid, solid-state power line protector. Features such as noise filtering, common mode and normal mode suppression, nanosecond reaction time, power line tracking, and compression screw terminations make the Edco HSP121BT-1RU an excellent choice in commercial and industrial applications. The Edco HSP121BT-1RU offers a replaceable fuse designed to remove the load (protected equipment) from the line if the unit is either overloaded or the internal protection fails. This feature prevents surges from entering equipment through a failed protector not noticed by the user. Features ■ Fast response time ■ 3-stage hybrid design ■ Failure indicator ■ Replaceable fuse ■ Power line tracking ■ UL 1449 recognized ■ Filtering ■ 5 year warranty General Technical Specifications Installation Part Number 1. Mount Edco HSP121BT-1RU in a UL approved housing. Edco HSP121BT-1RU Operating Voltage 120 VAC Clamping Voltage 325 VAC Operating Current 15A Peak Surge Current 13 kA/Mode, 26 kA/Phase, 39 kA/Total Operating Frequency 47-63 Hz EMI Attenuation > 40 dB SPD Technology Metal Oxide Varistors (MOVs) w/L-C Filter Modes of Protection Line-to-Neutral, Line-to-Ground, Neutral-to-Ground Status Indication Power On & MOVs functional Connection Type 3 position, 20A terminal block w/ compression screws Terminals accept up to 14 AWG Operating Temperature Dimensions (Inches) Weight Certifications 2. Make sure wiring from power sources properly connects to LINE side of HSP. Wiring from protected equipment must properly connect to EQUIP side of HSP. 3. Connect only to 120 VAC, 15 Amp max., single phase, three-wire circuit. 4. Indication of internal failure: a. Indicator will extinguish. b. Fuse blown will disconnect load from power source. Dimensions HOLES 3/16 " DIA 1.17" 1.17" 120 VAC 15 AMPS MAX AC L I NEUT N E GRD E Q U I P AC NEUT 2.95" GRD LIGHT ON – NORMAL LIGHT OFF – REQUIRES SERVICE 4.86" 5.25" Warning: For continued protection against risk of fire, replace only with same type rating of fuse (3AB, 15A/250V). -40°C to +85°C 1.8H x 2.9W x 5.3L 10 oz UL 1449 recognized, ISO 9001:2000 7 AC Power — Series Connected Islatrol® — SP-6TVN Industrial Strength Surge Suppression (Series) The Islatrol® SP-6TVN is an industrial-strength surge suppression/filtering device that plugs into a standard duplex receptacle. It features uniquely designed repositionable outlets and protects against damaging power disturbances traveling through your wiring into your electrical outlets. Features REPOSITIONABLE OUTLETS UL ® 1449 ■ Plugs into standard 120 V, 15 Amp electrical outlet ■ Intelligent monitoring against improper wiring/grounding ■ Total peak surge current capacity of 39,000 Amps ■ 60 dB maximum high frequency ■ Cables for telephone, video, and data connectors ■ 5 year limited warranty ■ Operational indicator lamp ■ Repositionable outlets rotate to accommodate available space General Technical Specifications ANSI/IEEE C62.41 Cat A Ringwave (6 kV, 200 A, 100 KHz) AC Power Protection Part Number Nominal Operating Voltage Operating Voltage Range Operating Frequency Range Rated Output (Amps) ANSI/IEEE C62.41 Category Connection Type Phase Configuration Size Enclosure Weight Modes Of Protection Indication of Suppression Status Response Time Certifications Warranty Islatrol® – SP-6TVN 120 VAC, Single Phase 47 – 63 Hz 15 Amperes Category A & B (6) 5-15R Receptacles and 5-15P Plug 2 Wire + Gnd 7.5 x 4.75 x 1.75 (Inches) 8 290 V ANSI/IEEE C62.41 Cat B Ringwave (6 kV, 500 A, 100 KHz) Normal Mode 275 V Common Mode 290 V Frequency Response Normal Mode Common Mode 60 dB maximum, forward/reverse, 100 KHz to 50 MHz 40 dB maximum, forward/reverse, 5 MHz to 50 MHz High Impact Plastic 2.0 lbs (0.9 kgs) Low Voltage Protection Video 1 & 2 Phone Network Connection Type Type “F” Type RJ-11 Type RJ-45 Cables Provided 6' (2x) Type “F” Ends 6' RJ-11 Male Ends 6' RJ-45 Male Ends 5 kA (8 x 20 μs) 2 kA (10 x 1000 μs) 3 kA (8 x 20 μs) L – N, L – G, N – G Status Indicator < .5 ns Normal Mode UL 1449 Listed 5 Year Peak Surge Current Capacitance 130 VAC Protection Level Clamping Voltage (DC) Attenuation Peak Surge Current (8 x 20 μs) Line to Neutral 265 V Common Mode 120 VAC +/- 10% Maximum Continuous Operating Voltage (MCOV) Line to Neutral Normal Mode 13,000 Amps Line to Ground 13,000 Amps Neutral to Ground 13,000 Amps Total 39,000 Amps <12 pf <50 pf <70 pf L-G T-R, T-G, R-G L-G (8 Lines) 145 V 270-350 V 30 V 1 dB @ 2 GHz N/A N/A AC Power — Series Connected Islatrol® — RM Series 120 VAC Rackmount This line of AC surge protectors is ideal for protecting the power feeding valuable rack equipment. All models provide ten protected outlets on the back and two protected convenience outlets on the front. This series provides 40,000 Amps of surge protection and up to 60 dB of highfrequency noise filtering. Status LEDs indicate the correct power is coming to the unit, whether the unit is properly grounded and whether the surge components are still intact. Units are available with an optional digital meter, mounted on the front of the unit, that will monitor the voltage, current and power of the protected equipment. Model shown: RM-115-10 RM Features ■ 40 kA surge protection ■ Digital meter ■ 60 dB max noise filtering ■ Optional twist lock plug ■ 15 A & 20 A models available ■ 1 year warranty ■ Power, ground and surge status indicators General Technical Specifications Part Number Voltage Amperage Plug (NEMA) Receptacles (NEMA) Digital Meter Locking Plug RM-115-10RM 120 V 15 A 5-15P 5-15R Yes No RM-120-10RM 120 V 20 A 5-20P 5-20R Yes No RM-120-10RML 120 V 20 A L5-20P 5-20R Yes Yes Rackmount AC Power Protection Rated Voltage 120 V Rated Current 15 A & 20 A Peak Surge Current Response Time EMI/RFI Filtering LED Indicators Digital Meter Input Power 15 A Models 20A Models 20 kA/mode, 40 kA/phase <5 ns 60 dB Max Green-Power On Green-Ground OK Green-Surge Circuit OK Voltage Amps, Watts, VA, Hz, PF, Kwh, and Clock Output Receptacles 15 A Models 20 A Models Thermal Protection Over-current Protection Dimensions Warranty Front- (2) NEMA 5-15R Back- (10) NEMA 5-15R Front- (2) NEMA 5-20R Back- (10) NEMA 5-20R Thermal Protected MOVs Circuit 1.75"H x 19"W x 2.0"D (1U) 1 Year SJT 14/3C Power Cord (15 ft) with NEMA 5-15P Plug SJT 12/3C Power Cord (15 ft) with NEMA 5-20P Plug NEMA L5-20P Plug- Optional 9 AC Power — Series Connected Edco SHA-1230FS 120 VAC — 1 Phase — 30A FingerSafe The Edco SHA-1230FS is a FingerSafe 120 VAC Single Phase 2W+G, 30A surge suppressor/filter designed to shunt electrical type transients affecting the electrical distribution inside a traffic cabinet. The Edco SHA-1230FS offers 50 kA per Mode and 100 kA per Phase of surge current protection. The Edco SHA-1230FS utilizes Thermally-protected Metal Oxide Varistors (TMOVs) with an integrated thermally activated element designed to open in the event of overheating due to the abnormal over-voltage, limited current conditions. Features ■ 120 VAC, 30A service ■ Thermally-protected Metal Oxide Varistors (TMOVs) ■ FingerSafe connection ■ 50 kA/Mode and 100 kA/Phase surge current protection ■ Power On and failure LED ■ 5 year warranty General Technical Specifications Part Number Mounting Edco SHA-1230FS Operating Voltage 120 VAC Clamping Voltage 400 VAC Operating Current 30A Peak Surge Current Hole (4 places) 3/16" dia. 50 kA/Mode, 100 kA/Phase, 150 kA Total Operating Frequency 47-63 Hz EMI Attenuation 40 dB typ SPD Technology MOVs w/L-C Filter Modes of Protection PLATE Power On & MOVs functional Connection Type Recessed Terminal Screws Operating Temperature -40°C to +85°C Dimensions (Inches) 1.875H x 3.25W x 5.75L Weight 12 oz Certifications ISO 9001:2000 5.75" Caution: 1. This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specification. Appropriate precautions should be exercised. 2. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only. Installation Diagram Option Line Load L Line Input From Source N GND 10 L L N N GND GND To Load or Equipment to Protect 3.25" 5.25" L-N, L-G, N-G Status Indication 2.25" DIN Rail Kit Available. Order Part # 11604KIT AC Power — Series Connected Edco SHA-1260 120 VAC — 1 Phase — 60A The Edco SHA-1260 is a 120 VAC Single Phase 2W+G, 60A surge suppressor/filter designed to shunt electrical type transients affecting the electrical distribution inside a traffic cabinet. The Edco SHA-1260 offers 50 kA per Mode and 100 kA per Phase of surge current protection. The Edco SHA-1260 utilizes Thermally-protected Metal Oxide Varistors (TMOVs) with an integrated thermally-activated element designed to open in the event of overheating due to the abnormal over-voltage, limited current conditions. Features ■ 120 VAC, 60A service ■ Thermally-protected Metal Oxide Varistors (TMOVs) ■ Phosphor bronze stud for substantial conductivity ■ 50 kA/Mode and 100 kA/Phase surge current protection ■ Power On and failure LED Installation General Technical Specifications Part Number ■ 5 year warranty Edco SHA-1260 Operating Voltage Line 120 VAC Clamping Voltage 400 VAC Operating Current 60A Peak Surge Current 50 kA/Mode, 100 kA/Phase, 150 kA/Total Operating Frequency 47-63 Hz EMI Attenuation 40 dB typ SPD Technology MOVs w/L-C Filter Modes of Protection Load L Line Input From Source N GND L L N N GND To Load or Equipment to Protect GND L-N, L-G, N-G Status Indication Power On & MOVs functional Connection Type Phosphor Bronze 1/4-20 Stud Operating Temperature -40° C to +85° C Dimensions (Inches) 3.5H x 4.75W x 7.25L Weight 2 lbs Certifications ISO 9001:2000 Caution: 1. This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specification. Appropriate precautions should be exercised. 2. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only. Mounting Hole (4 places) 3/16" dia. PLATE 3.5" 4.75" 6.75" 7.25" 11 AC Power — Series Connected Islatrol® INXT120NL000-1 AC Power Line Filter The Islatrol® INXT120NL000-1 is a 120 VAC, 60A, EMI/RFI filter. The INXT is a series connected device designed to filter electrical type transients impinging on electrical distribution of a traffic control cabinet. Features ■ 60 Amp Series Filter ■ Epoxy encapsulated ■ 50 dB attenuation (200 KHz to 75 MHz) ■ 5 year limited warranty ■ High impact thermoplastic enclosure General Technical Specifications Islatrol® INXT120NL000-1 Part Number Nominal Operating Voltage 120 VAC Operating Voltage Range 120V ±25% Operating Frequency Range 47-63 Hz Connection Type 1/4 -20 Studs Amperes Phase Configuration 60 Amperes Single Phase 2 wire (Line and Neutral) Size 3.9” x 4.4” x 1.6” Weight 2 lbs. Maximum Continuous Operating Voltage (MCOV) Load Surge Current Rating 10 MSEC 1 SEC 5 SEC Transient Reduction/ Frequency Attenuation Packaging Operating Temperature Operating Humidity Operating Altitude Certifications Warranty 12 240 VAC 100 x Nominal 10 x Nominal 5 x Nominal 50 dB min (200 KHz to 75 MHz) Black, high impact plastic case, epoxy encapsulated. -40°C to +45°C derate linearly to 70% @ 70°C 0 to 95% non-condensing -100m to 2000m ISO 9001, IEC-610 Complies with the requirements of UL1283 5 Years AC Power — Parallel Connected PowerSure® EMC-240B 120/240 VAC Heavy Duty (Parallel) The PowerSure® EMC-240B is a rugged, highly reliable panel surge protector for residential or commercial standard 120/240V single or split phase applications. The PowerSure® EMC-240B features totally solid state construction for reliability and quick response to surges. Two advanced, metal oxide varistors (MOVs) are the primary protective elements. These MOVs are each capable of 40,000 Amps of surge current. Features ■ Fast response time ■ Operational status indicators ■ 80,000 Amps total peak surge current ■ UL dual listed — TVSS/Arrester (NEC Article 280) ■ Failsafe and fused UL ® ■ 5 year warranty 1449 General Technical Specifications Mechanical PowerSure® EMC-240B Part Number Operating Voltage 120/240 VAC Clamping Voltage 395 VAC Operating Current 2.8" 2.2" NA, Parallel Peak Surge Current 40 kA/Mode, 40 kA/Phase, 80 kA/Total Fault Current Rating (AIC) 42 kAIC Operating Frequency 4.5" 47-63 Hz EMI Attenuation NA SPD Technology MOVs Modes of Protection L-L, L-N Status Indication 18" Power On & MOVs functional Connection Type Wire Leads Operating Temperature -40°C to +85°C Dimensions (Inches) 4.6H x 2.2W x 2.8L Weight 13.5 oz Certifications UL 1449, OWHX, ISO 9001:2000 Caution: Installation and service should be performed by qualified electricians only. Before installing EMC, remove all electrical power from circuits. Connect on load side of main breakers. Use 2 dedicated 30A circuit breakers. Installation L1 L 120 V N EMC-240B 240 V N L2 L1 120 V 240 V GND 120 V EMC-240B Black Black White Green Ground N L 240 VAC Service 120/240 V AC Service 120 V AC Service L2 240 V 240 V Black Black White Green EMC-240B Black Black White Green Ground L2 N L1 L2 GND L1 13 AC Power — Parallel Connected PowerSure® FAS-120AC Medium Duty 120 VAC — 1 Phase The PowerSure® FAS-120AC surge suppressor is designed to protect AC distribution panel circuits or 120V power supplies feeding sensitive electronic equipment. Electrically the unit incorporates MOV and thermal fusing technology. This device is designed to be installed in parallel on standard single phase 120 VAC (L,N,G) circuits. Installation can be close-nipple up to a distribution panel/circuit or hardwired in parallel up to power supply input terminal screws. Be sure to dress leads as short as possible. Features UL ® 1449 ■ LED indicator ■ Compact size ■ Fast response time ■ Liquid tight conduit fitting ■ Thermal fuse ■ UL 1449 listed ■ L-G, L-N, N-G protection ■ 5 year warranty General Technical Specifications Mounting ® Part Number PowerSure FAS-120AC Operating Voltage 120 VAC Clamping Voltage 325 VAC Operating Current NA Peak Surge Current 2.5" 6.5 kA/Mode, 13 kA/Phase, 15.5 kA/Total Operating Frequency 47-63 Hz EMI Attenuation NA SPD Technology MOVs Modes of Protection Status Indication L-N, L-G, N-G Power On & MOVs Functional Connection Type Wire Leads Operating Temperature Dimensions (Inches) Ø0.1860 -40°C to +85°C 2.5H x 1.5W x 3.0L Weight Certifications 1.5" 4 oz UL 1449, ISO 9001:2000 Caution: This product should be installed and serviced by qualified service technicians or personnel only. Remove power before installation or service. 14 3" AC Power — Parallel Connected Edco SPA-300 Medium Duty 120 VAC — 1 Phase The Edco SPA-300 is designed to protect sensitive electronic equipment such as traffic controllers, from high energy surges. The Edco SPA-300 incorporates MOV technology which clamps these surges before equipment damage occurs. The Edco SPA-300 is intended for use on bonded neutral to ground applications. Features ■ 40 kA surge protection ■ Epoxy encapsulated ■ Fast response time ■ 5 year warranty ■ Solid-state design General Technical Specifications Part Number Installation Edco SPA-300 Operating Voltage 120 VAC Clamping Voltage 395 VAC Operating Current NA Peak Surge Current 40 kA/Mode/Phase/Total Operating Frequency 47-63 Hz EMI Attenuation NA SPD Technology MOVs Status Indication NA Connection Type 1/4 -20 Stainless Steel Stud Operating Temperature -40°C to +85°C Dimensions (Inches) Hot 120 VAC Line Neutral 1.875H x 2.875W x 5.25L Weight Ground 1 lb Certifications Load SPA-300 ISO 9001:2000 Caution: This product should be installed and serviced by qualified service technicians or personnel only. Mounting Remove power before installation or service. Hole 3/16" PLATE 2.875" 4.875" 5.25" 15 AC Power — Parallel Connected Edco SPA-100T AC Service Protection The Edco SPA-100T is a medium duty AC Service Arrester which is solid state in design. It is intended for equipment which is located in outdoor cabinets exposed to lightning transients. Application examples are railroad equipment, motor control cabinets, flasher cabinets, and traffic controllers. Features ■ Fast response time ■ Compact size ■ Solid-state design ■ 5 year warranty ■ Epoxy encapsulated Installation General Technical Specifications Part Number Edco SPA-100T Operating Voltage 120 VAC Clamping Voltage 395 VAC Operating Current NA Peak Surge Current 13 kA/Mode/Phase/Total Operating Frequency CB 120 / VAC Input Line Hot 47-63 Hz EMI Attenuation NA SPD Technology MOVs Status Indication NA Connection Type 10-32 Stainless Steel Stud Operating Temperature Dimensions (Inches) 120 VAC SPA-100T Keep Leads Short and Straight Neutral Ground -40°C to +85°C 0.5H x 1.5W x 2.0L Weight 2 oz Certifications ISO 9001:2000 Caution: 1. Install SPA-100T on load side of breaker as shown. 2. Installation and service should be performed by qualified personnel only. Mounting 3. Remove all electrical power from circuits before installing SPA-100T. 1" 1.5" 1.5" 2" 16 Load AC Power — Parallel Connected Edco SHA-1201 120 VAC – 1 Phase The Edco SHA-1201 is specifically designed for type 170 Traffic Controller cabinets that require power neutral to remain isolated from cabinet earth ground. Protection is provided both between phase-to-neutral, and neutralto-ground. If neutral is bonded to earth ground in the cabinet, the Edco SPA-100T unit should be considered as a cost-effective alternate to the Edco SHA-1201. Features ■ 53 kA surge protection ■ Epoxy encapsulated ■ Fast response time ■ 5 year warranty ■ Solid-state design General Technical Specifications Part Number Installation Edco SHA-1201 Operating Voltage 120 VAC Clamping Voltage 395 VAC Operating Current NA, Parallel Peak Surge Current 40 kA/Mode, 40 kA/Phase, 53 kA/Total Operating Frequency Hot Black Grnd SHA-1201 Equipment 47-63 Hz EMI Attenuation NA SPD Technology 120 Vac Neutral White MOVs Modes of Protection L-N, N-G Status Indication NA Connection Type Earth Ground Chassis Ground Leads Operating Temperature -40°C to +85°C Dimensions (Inches) 3L x 2W x 1H Weight 6 oz Certifications Caution: Installation and service should be performed by qualified technicians or service personnel only. ISO 9001:2000 Mounting 2" 1.5" 3" 2.5" 3/16" Diameter Hole 17 AC Power — Parallel Connected PowerSure® DRS Series Modular Surge Protective Device (SPD) designed to be easily installed in existing AC panelboards and control panels using standard DIN rail mounting brackets. These devices offer both normal and common surge protection up to 40 kA per phase. Features ■ Effectively handles high-energy transients on TT, TN-C, TN-S and TN-C-S three-phase power systems ■ SPD rated Type 2 in accordance with EN 61643-11; Class I & II in accordance with IEC 61643-1 ■ Built-in thermal components disconnect SPD from the power source to avoid thermal runaway conditions ■ MOV only or MOV+Gas Tube models available ■ Fast response time, high surge current capability, low voltage protection levels ■ Visual inspection window on each module indicates status ■ 3-pole terminal provides remote status monitoring ■ DIN rail mounting and plug-in module design allow for easy installation, maintenance and replacement of surge element ■ 5 year warranty General Technical Specifications DRS12031 DRS23031 DRS27731 DRS34631 Electrical Characteristics System Voltage 120/208, 230/400, 220/380, 277/480, 346/600 VAC 127/220 VAC 240/415 VAC 254/440 VAC Type of Network TT-TN TT-TN TT-TN TT-TN Modes of Protection L-N; N-PE L-N; N-PE L-N; N-PE L-N; N-PE Nominal Voltage Un–120 V Un–230 V Un–277 V Un–346 V Rated Voltage (MCOV) Uc–150 V Uc–320 V Uc–320 V Uc–420 V Nominal Discharge Current (8 x 20 μs) 1n–20 kA 1n–20 kA Maximum Discharge Current Imax–40 kA Imax–40 kA Imax–40 kA Imax–40 kA Voltage Protection Level Up–1.2 kV Up–1.6 kV Up—1.6 kV Up–2.0 kV Response Time TS–25 ns TS–25 ns TS–25 ns TS–25 ns 95% 95% 95% 95% Risol > 103 MV Risol > 103 MV Risol > 103 MV Risol > 103 MV 1n–20 kA EN 61643-11 Type 2 IEC61643- 1:1998-02 Class II Mechanical Characteristics Dimensions (Length x Width x Height) I/O Connections 70.8mm x 90.5mm x 68mm By Screw Terminal: 4-25 mm2 By Connection Bus MOV Encapsulation Material Disconnection Indicator Status Monitoring Mounting Epoxy Resin Mechanical Indicator Remote Alarm Terminals Symmetrical Rail (EN50022/DIN46277-3) Operation Temperature Range Relative Humidity Isolation Resistance 1n–20 kA Test Standards -40°C to +85°C Degree of Protection Disconnection Device IP 20 Thermal Cutoff System Housing Material ABS/PA UL94V0 How to Specify the Appropriate Model Example: DRS 120 3 1 Q Nominal Voltage (Un) (XXX) 120 0 230 1 240 2 277 3 346 4 480 600 18 # of Metal Oxide Varistor Modules* (X) # of Gas Tube Modules** (X) 0 Higher Rated Voltage*** (Optional) Q 1 *MOV modules are typically one module per phase and may be wired L-N, L-G or N-G. **Gas Tube modules typically used in the N-G mode for type TT grounding systems. *** Certain applications require higher rated components in order to survive frequent voltage rises, in this case order a unit with a “Q” at the end of the part number. Replacement modules available: Order DRS + Un + M (for MOV) or G (for Gas Tube) Low Voltage DC Power Edco FAS-1 and FAS-2 Series One and Two Pair Signal Line Protector (Commercial) The Edco FAS-1 and Edco FAS-2 Series are multi-stage single pair or two pair surge suppressors designed for high exposure applications. These products were specifically designed to meet multiple low voltage protection applications where operating currents can be as high as 2.5 Amps. Features ■ Lightning protection for low voltage data/ signal lines ■ Common mode and differential mode protection ■ Multi-stage protection ■ Automatic recovery ■ 5 year warranty UL ® 497B General Technical Specifications Part Number 15, 24, 36, 52 VDC Clamping Voltage 18, 33, 43, 60 VDC Operating Current 2.5A Peak Surge Current 10 kA (8 x 20 μs) Frequency Range 0 to 10 MHz SPD Technology GRO UND LU G Terminal block w/compression lugs Terminals accept up to 12 AWG 24 VDC use: FAS-1-033 HC (single pair) FAS-2-033 HC (two pair) 24 VAC use: FAS-1-043 HC (single pair) FAS-2-043 HC (two pair) 10–14 AWG -40°C to +85°C FAS-1 = 1.5H x 1.5W x 2.8L FAS-2 = 2H x 2W x 2.8L FAS-1 = 3.5 oz *FAS-1-060 HC (single pair) *FAS-2-060 HC (two pair) *Not UL Listed LINE. Certifications FAS-1-018 HC (single pair) FAS-2-018 HC (two pair) 48V Systems use: GDT, SAD, w/Series Inductor Operating Temperature Weight 12 VDC use: < 0.1 dB at 10 MHz EQ U I P. Insertion Loss Dimensions (Inches) Ordering Information U N PROT EC T E D O R F I E L D S I D E Edco FAS-1 and FAS-2 Series Operating Voltage Connection Type Installation <3 Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continuously supplying more than 2.5 amperes. FAS-2 = 7 oz UL 497B, ISO 9001:2000 PROTEC TED EQ UIP. DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. 19 Low Voltage DC Power Edco PHC Series Two-Pair Signaling Circuit Protector (Modular) The Edco PHC Series is designed to protect two pairs of wires specifically where operating currents can be as high as 5 Amps. Electrically, the Edco PHC Series is a rugged series hybrid implementing a staged complement of MOVs, copper wound inductors and Silicon Avalanche Diodes. This design reduces series resistance to 0.2 Ohms per pair. The Edco PHC modules plug into a base assembly (Edco PCB1B). The base assembly can be mounted to any flat surface and should be located as close as practical to the protected equipment. Terminal 1 and/or terminal 10 should be connected to Building-Approved Ground with 12 or 10 gauge solid wire. Features EDCO PCB1B BASE SOLD SEPARATELY UL ® 497B ■ Three-stage protection ■ Continuous current up to 5 Amps ■ Differential protection ■ UL 497B listed ■ Common mode protection ■ Requires Edco PCB1B base ■ Plug-in module ■ PC642PTU (Pass Thru Unit) available for troubleshooting ■ Automatic recovery ■ 5 year warranty ■ Fast response time General Technical Specifications Part Number Edco PHC Series 15, 20, 30, 36, 43, 60, 70, 150 VDC Operating Current Peak Surge Current Frequency Range Insertion Loss SPD Technology Connection Type Operating Temperature Dimensions (Inches) 5A 10 kA (8 x 20 μs) 0 to 10 MHz -40°C to +85°C 3.7H x 1.75W x 2.375L (PHC + PCB1B Base) 8 oz UL 497B, ISO 9001:2000 Applications Part Number 24V Horn, Strobe, Bell: 70V Speaker Lines: 20 10 9 Unprotected Pair 2 { Field Side Unprotected Pair 1 8 7 6 5 { PHC-043 & PCB1B PHC-SP70 & PCB1B } 2 1 Protected Pair 2 Electronics Side 2.125" 2.4" 4 3 } Protected Pair 1 Keying Pin 1.0 MOV, SAD, w/Series Inductor Weight Certifications Even Terminals < 0.1 dB at 10 MHz Terminal block w/compression lugs Terminals accept up to 10 AWG How to Specify the Appropriate Model PCB1B: Odd Terminals Operating Voltage 12, 18, 24, 30, 36, 52, 60, 120 VDC Clamping Voltage Ordering Information Terminal Assignments Ground Terminal 1 or 10 to Building Approved Ground DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. Dimensions Input Files/Loop Detection Edco SRA6LC Series Vehicle Loop Detection The Edco SRA6LC Series are three terminal devices, two of which are connected across the signal inputs of the detector for differential mode protection, and the third is grounded to protect against common mode damage. This unit addresses over-voltage transients on both common and differential modes with state-of-the-art silicon breakover devices. The Edco SRA6LC Series is intended for all popular makes of loop detectors presently on the market. Features ■ Differential and common mode protection ■ Epoxy encapsulated ■ Fast response time ■ 5 year warranty ■ Easy installation ■ Compatible with digital detectors General Technical Specifications Installation Ordering Information Part Number General: Units are installed as close as practical to the point where the detector loop wires enter the controller cabinet. Connect one of the leads to each loop. The common (either the bolt, green wire or center clip) connection must be connected to earth ground. Best performance is obtained by shortening the leads as much as possible, and providing the lowest impedance to ground. One Edco SRA6LC is used on each loop detector circuit to be protected. SRA6LC Edco SRA6LC Operating Voltage 75 VDC Clamping Voltage 130 VDC Operating Current NA Peak Surge Current 250A SPD Technology Silicon Breakover Device Operating Temperature -40°C to +85°C Certifications ISO 9001:2000 Weight Dimensions: SRA6LC SRA6LC W/LEADS Mounting: SRA6LCA-716 SRA6LCA-916 SRA6LCB SRA6LCBLL 3 oz 1.2" Square cube 1.2" Square cube 7/16" Terminal Strip Spacing 9/16" Terminal Strip Spacing 9/16" Terminal Strip Spacing 9/16" Terminal Strip Spacing The Edco SRA6LCA slips under the equipmentside screws of the terminal strip. (See Drawing A) The protector ground is the center spade of the 3 spade terminations. The terminal strip must jumper this corresponding position to ground. Protectors can be mounted consecutively along the terminal strip. Cube, 2 leads + stud SRA6LC W/LEADS Cube, 3 leads/no stud SRA6LCA-716 3 Spaded Term. Block 7/16 Spacing SRA6LCA-916 3 Spaded Term. Block 9/16 Spacing SRA6LCB 2 Spaded Term. Block w/3.5" Gnd Wire SRA6LCBLL 2 Spaded Term. Block w/11" Gnd Wire Caution: Installation and service should be performed by qualified technicians or service personnel. Drawing A The Edco SRA6LCB slips under the equipmentside screws of the terminal strip. The protector ground wire must be bonded in a short, direct manner to the cabinet power ground. Protectors can be mounted consecutively along the terminal strip. The Edco SRA6LC has mounting brackets available for installing multiple units in the controller cabinet. The brackets are capable of mounting four or eight devices in-line. 21 Input Files/Loop Detection Edco SRA16C-1 Vehicle Loop Detection The Edco SRA16C-1 is a three terminal device, two of which are connected across the signal inputs of the detector for differential mode protection, and the third is grounded to protect against common mode damage. Differential mode surges (induced voltage across the loop detector input terminals) are clamped by a semiconductor array instantly. The array is designed to appear as very low capacitance to the detector. Common mode surges (induced voltage between the loop leads & ground) are handled by a rugged three-element gas discharge tube which operates (fires) at 90 VDC and thereafter clamps the two loop leads to 30 volts in respect to ground. This design eliminates any ground noise from entering the loop detector and being amplified. The Edco SRA16C-1 is intended for all current detector models on the market. Features ■ Rugged gas tube protection ■ Compatible with digital detectors ■ 5 year warranty General Technical Specifications Installation Part Number Edco SRA16C-1 Operating Voltage 75 VDC Clamping Voltage 90 VDC Operating Current NA Peak Surge Current Mounting brackets are available for installing multiple units in the controller cabinet. The brackets are capable of mounting four or eight devices in-line. One Edco SRA16C-1 is used for each loop detector to be protected. Units are installed as close as practical to the point where the detector loop wires enter the controller cabinet. Connect one of the flexible leads to each end of the loop. The common (bolt) connection on each Edco SRA16C-1 must be connected to earth ground. 10 kA SPD Technology GDT Connection Type Leads Operating Temperature Best performance is obtained by (1) shortening the flexible leads as much as possible, and (2) providing the lowest possible impedance to ground. -40°C to +85°C Dimensions 1" Sq., Ht. 2" max Mounting NOTE: The Edco SRA16C-1W/LEADS (special order) is installed very similar to the standard unit except the common (bolt) is replaced with a green wire. No. 10 - 32 x 3/8" stud Weight 3 oz Certifications ISO 9001:2000 Edco MRA-6LC-6 Vehicle Loop Detection Protector The Edco MRA-6LC-6 is a modular device utilizing solid state silicon foldover technology. The Edco MRA-6LC-6 is designed for any traffic controller cabinet equipped with 6 position, 5.08mm spacing sockets wired in line with load relay outputs. Features ■ Modular design ■ Differential and common mode protection ■ Fits 6 position, 5.08mm spacing sockets ■ 5 year warranty ■ Designed for digital detector General Technical Specifications Part Number 75 VDC Clamping Voltage 130 VDC Operating Current NA Peak Surge Current SPD Technology Connection Type Operating Temperature Dimensions (Inches) 22 Edco MRA-6LC-6 Operating Voltage 250A Silicon Breakover Device 6 position 5.08mm Euroblock -40°C to +85°C 2H x 0.7W x 1.5L Weight Certifications 2 oz ISO 9001:2000 Installation One Edco MRA-6LC-6 is used for each two loop detectors to be protected. Units are installed as close as practical to the point where the detector loop wires enter the controller cabinet. Caution: Installation and service should be performed by qualified technicians or service personnel. Output Files Edco SPA-303 120 VAC Load Relay The Edco SPA-303 is a three circuit protective device intended for use on traffic control load relay outputs. The protector is furnished with three leads and a ground stud. Features ■ 5 year warranty ■ Convenient mounting/grounding stud ■ Compact size Mounting General Technical Specifications Part Number Edco SPA-303 Operating Voltage 120 VAC Clamping Voltage 395 VAC Operating Current NA Total Peak Surge Current Caution: To prevent shock hazard, this product should never be ungrounded (bolt disconnected from ground) when power is applied to leads. 39 kA Operating Frequency 47-63 Hz EMI Attenuation NA SPD Technology MOVs Status Indication NA Connection Type Leads Operating Temperature 1.5" SPA-303 -40°C to +85°C Dimensions (Inches) 5/8" 1" 1.5H x 1W x 2.125L Weight 5 oz 2.125" Certifications ISO 9001:2000 Edco MPA-303 Series Modular Output File Protector The Edco MPA-303 Series is a modular device intended for use on traffic control load relay outputs. The Edco MPA-303-9 unit will protect six output circuits. The Edco MPA-303-6 unit will protect four output circuits. The Edco MPA-303-9 is designed for any traffic controller cabinet equipped with 9 position, 5.08mm spacing sockets wired in line with load relay outputs. The Edco MPA-303-6 is designed for 6 position, 5.08mm spacing sockets. Features ■ Modular design for 6 and 4 output circuits ■ 5 year warranty ■ Fits 6 and 9 position, 5.08mm spacing sockets General Technical Specifications Part Number Edco MPA-303 Series Connection Type Operating Voltage 120 VAC Operating Temperature Clamping Voltage 340 VAC Dimensions (Inches, Module only) Operating Current Total Peak Surge Current Operating Frequency NA 26k (6 pos), 39k (9 pos) Weight Certifications 6 or 9 position 5.08mm Euroblock -40°C to +85°C 2.0H x 0.7W x 2.0L 2 oz ISO 9001:2000 47-63 Hz EMI Attenuation NA SPD Technology MOVs Status Indication NA Caution: This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specification. Appropriate precautions should be exercised. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only. 23 Communication Lines Edco PC642 Series Zone/Loop/Data The Edco PC642 Series surge suppressor is a two-pair (four-wire) module implementing three-stage hybrid technology. This module addresses over-voltage transients with gas tubes and silicon avalanche components. In addition, sneak and fault currents are mitigated with resettable fuses (PTCs). The PTCs increase resistance several orders of magnitude when over-currents exceed safe levels. A normal state resumes when over-currents are removed. The ability to self-restore in this manner significantly increases suppressor performance and survivability. The Edco PC642 card edge module is gold-plated, double-sided, and is designed to mate with the Edco PCB1B gold-plated female terminal connector. When snapped together, the data circuits “pass thru” the protector in a serial fashion from the four “Field Side” terminals to the four “Electronics Side” terminals. Terminals 1 or 10 of the Edco PCB1B must be attached to Building-Approved Ground per Edco Technical Bulletin # 2015. EDCO PCB1B BASE SOLD SEPARATELY UL ® 497B Features ■ Three-stage hybrid protection ■ Fast response time ■ Sneak/fault current protection ■ Requires Edco PCB1B base ■ Resettable fusing — PTCs ■ PC642PTU (Pass Thru Unit) available for troubleshooting ■ Low capacitance option ■ 5 year warranty ■ Plug-in module General Technical Specifications Terminal Assignments Part Number Edco PC642 Series Operating Voltage Clamping Voltage Operating Current Peak Surge Current Frequency Range Insertion Loss Certifications { Field Side 8 7 6 5 { Unprotected Pair 1 } 3 2 } Protected Pair 1 Keying Pin 1.0 Ground Terminal 1 or 10 to Building Approved Ground DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. Ordering Information -40°C to +85°C 2H x 1W x 2.5L (PC642 + PCB1B Base) Protected Pair 2 Electronics Side 2.125" 2.4" 4 1 0 to 20 MHz APPLICATION: PC642 RS485, RS422: PC642C-008LC & PCB1B RS423, Token Ring: PC642C-008LC & PCB1B RS232: 1 oz E-NET, 10 BASE T: UL 497B, ISO 9001:2000 Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of supplying more than 150 milliamperes continuously. 24 10 9 Unprotected Pair 2 PC642C Even Terminals 10 kA (8 x 20 μs) Terminal block w/compression lugs Terminals accept up to 10 AWG Dimensions (Inches) PCB1B: Odd Terminals 0.15A GDT, SAD, w/Series PTC Operating Temperature Weight 8, 15, 20, 30, 36, 43, 50, 60, 200 VDC < 0.1 dB at 20 MHz SPD Technology Connection Type 5, 12, 18, 24, 30, 36, 43, 52, 180 VDC How to Specify the Appropriate Model 4–20ma: PCB1B PC642C-020 & PCB1B PC642C-030LC & PCB1B PC642C-036 & PCB1B VOLTAGE CLAMP 8 Volts 15 Volts 20 Volts 30 Volts 36 Volts 43 Volts 50 Volts 60 Volts *200 Volts •Not UL Listed 0 0 0 0 0 0 0 0 2 0 1 2 3 3 4 5 6 0 8 5 0 0 6 3 0 0 0 D no suffix stage 2 clamp each line-to-ground stage 2 clamp line-to-line only recommended for traffic comm. lines X stage 2 clamp line-to-line and each line to ground LC low capacitance option stage 2 clamp line-to-line and each line to ground Use “D” Suffix for Traffic Communication Lines Option DIN Rail Kit Available. Order Part # 11604KIT-PC Communication Lines Edco SRA64 Series 1 Pair Data/Signal The Edco SRA64 Series surge suppressor is a single pair cube implementing three-stage hybrid technology. This cube addresses over-voltage transients with gas tubes and silicon avalanche components. In addition, sneak and fault currents are mitigated with resettable fuses (PTCs). The PTCs increase resistance several orders of magnitude when over currents exceed safe levels. A normal state resumes when over-currents are removed. The ability to self restore in this manner significantly increases suppressor performance and survivability. The standard Edco SRA64 second stage clamps are placed from each signal lineto-ground. In certain cases, where ground potentials vary from site-to-site, a line-to-line only second stage clamp may be preferred. This variation is specified by a suffix “D” on the part number. In other cases, line-to-line and line-to-ground second stage clamps may be preferred. This variation uses an “X” suffix on the part number. UL ® A variety of clamping voltages are available as standard. Reference the “How to Specify the Appropriate Model” section to insure that a complete part number description is obtained. 497B Features ■ Lightning protection for balanced low voltage signal lines ■ Common mode protection ■ Multi-stage protection ■ Fast response time ■ Sneak/fault current protection ■ Flame retardant epoxy encapsulated ■ Differential mode protection ■ 5 year warranty General Technical Specifications Part Number How to Specify the Appropriate Model Edco SRA64 Series Total Peak Surge Current 10kA (8 x 20 μs) Response Time <1 nanosecond Voltage Clamp 8, 15, 20, 30, 36, 43, 50, 60, or 200 Resistance Temperature 5Ω (typical) -40°C to+85°C Weight Dimensions Mounting Stud (standard) ■ Automatic recovery 2 oz. 1.15" Cube No.10-32 x 1/2" SRA64C VOLTAGE CLAMP 8 Volts 15 Volts 20 Volts 30 Volts 36 Volts 43 Volts 50 Volts 60 Volts *200 Volts 0 0 0 0 0 0 0 0 2 0 1 2 3 3 4 5 6 0 8 5 0 0 6 3 0 0 0 D no suffix stage 2 clamp each line-to-ground stage 2 clamp line-to-line only X stage 2 clamp line-to-line and each line to ground •Not UL Listed Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal lines capable of supplying more than 150 milliamperes continuously Wiring Assignments BLACK WHITE FIELD SIDE (Outside Plant) ELECTRONICS SIDE (Equipment) BLACK/RED WHITE/RED 25 Video Edco SPA-60B Series 120 VAC Interconnect Signal The Edco SPA-60B is an economical method of protecting circuitry associated with 120 VAC interconnect signal lines commonly used in traffic control systems. In the presence of normal interconnect line voltage and frequency (60 Hz), the Edco SPA-60B possesses the ideal characteristics of high impedance across the protector and no impedance in series with the line. In the presence of transients, the protector appears as very low impedance, thereby shunting the surge to ground. The product is offered in four variations. The Edco SPA-60BL protects one circuit and is furnished with two leads. The Edco SPA-60BL-2 is identical except it protects two circuits and is furnished with three leads.The Edco SPA-60BS protects one circuit and consists of one lead and a stud (also used for mounting). The Edco SPA-60BS-2 is identical except it protects two circuits and consists of two leads and a stud. Refer to ordering information below. Features ■ Rugged gas tube protection ■ Various models available ■ Fast response time ■ 5 year warranty ■ Compact size General Technical Specifications Part Number Installation Edco SPA-60B Series Operating Voltage 120 VAC Clamping Voltage 350 VAC Operating Current NA Total Peak Surge Current Operating Frequency 47-63 Hz EMI Attenuation NA SPD Technology GDT Status Indication NA Connection Type Leads Operating Temperature -40°C to +85°C Size: BL Types BS Types 1.50" x .5" x .8" 1" cube Mounting Studs 10:32 x 3/8" SS Weight Certifications Note: This product is intended for use on 120 VAC interconnect lines. Do NOT use on AC service or power lines. 26 10 kA 2 oz ISO 9001:2000 Stud Mounting Unit: Connect black lead to interconnect signal line near entry point into cabinet. Shorten lead as much as possible. Bolt unit to clean metal surface bonded to power/earth ground (cabinet in most cases). Lead Supported Unit: Shorten leads. Connect between interconnect signal line and power/ earth ground. Ordering Information SPA-60B L Leads One circuit (blank) S Studs Two circuits 2 Video Edco CX Series CCTV Applications/Coax The Edco CX06-M and Edco CX06-MI Surge Protective Devices (SPDs) implement three-stage hybrid technology. The SPDs address over-voltage transients with a primary Gas Discharge Tube (GDT), and secondary Silicon Avalanche Diode (SAD) components. Over-current protection, e.g. sneak and fault currents, are mitigated with solid-state resettable fuses — PTCs. The Edco CX06-M and Edco CX06-MI SPDs are designed in accordance with NFPA 780 (2004 edition) requirements, with up to 20 kA of surge current capability. The Edco CX06-MI model has an isolated ground and is recommended for use at the camera end. Features UL ® 497B ■ Sneak/fault current protection ■ CX06-MI has an isolated ground ■ Low insertion loss ■ 5 year warranty ■ Shielded case General Technical Specifications Part Number Edco CX Series Frequency Range Operating Voltage 5 VDC Insertion Loss Clamping Voltage 6 VDC SPD Technology Operating Current 0.15A Connection Type Peak Surge Current 20 kA (8 x 20 μs) 0 to 20 MHz Dimensions (Inches) M = 1.5H x 1W x 3.25L MI = 1.5H x 1W x 4L < 0.1 dB at 20 MHz GDT, SAD, w/Series PTC BNC, 50/75 Ohm Operating Temperature Weight M = 2.3 oz Certifications MI = 3 oz UL 497B, ISO 9001:2000 -40°C to +85°C Option Ordering Information Head End CX06-M Camera End CX06-MI DIN Rail Kit Available. Order Part # 11604KIT-CX Modem Edco FAS-TEL-DOT RJ Connection Telephone Protection for Traffic Cabinets The Edco FAS-TEL-DOT is a single pair telephone protector that implements an advanced three-stage hybrid design. This unit addresses over-voltage transients with gas discharge tubes (GDT) and silicon breakover devices. Additionally, sneak and fault currents are mitigated with PTC technology, which consists of solid state resettable fuses. The Edco FASTEL-DOT is specifically designed for more rugged applications such as traffic cabinets. Features ■ Three-stage hybrid design ■ Fast response time ■ Rugged gas tube protection ■ 5 year warranty ■ Sneak/fault current protection Installation General Technical Specifications FAS-TEL-DOT Part Number Edco FAS-TEL-DOT SPD Technology GDT, Silicon Breakover w/PTC Operating Voltage 220 VDC Connection Type Clamping Voltage 270 VDC Operating Temperature Operating Current 0.15A Peak Surge Current Frequency Range Insertion Loss 10kA 0 to 20 MHz < 0.1 dB at 20 MHz Dimensions (Inches) Weight Certifications Term block, comp.lug IN / RJ OUT -40°C to +85°C 1H x 2W x 2L 2 oz To Phone or Computer Protected Side R1 T1 TELCO R T Building Approved Ground ISO 9001:2000 Unprotected Side Field 27 Data/Signal Line Edco RJA-RJD Series RJ-45 Telephone/Data The Edco RJA and Edco RJD Series are four pair telephone/data line protectors that implement advanced two stage hybrid design. These units address overvoltage transients with silicon breakover devices, while sneak and fault currents are mitigated with PTC technology, which consists of solid state resettable fuses. The Edco RJA and Edco RJD Series incorporate RJ-45 female jacks in and out. The Edco RJA voltage clamp is set for C.O. Trunks and Analog Telephone Extensions (with ring in voltage), and the Edco RJD voltage clamp is set for Digital Extensions (no ring in voltage). UL ® 497A Features ■ <1 nanosecond response time ■ Solid-state resettable fuses-PTCs ■ Silicon breakover technology ■ Low capacitance ■ Line-to-line protection General Technical Specifications Installation ■ Tip and ring to ground protection ■ CAN/CSA C22.2, No. 226-92 Compliant ■ UL 497A listed ■ 4 pair protection ■ 5 year warranty Ordering Information Edco RJA-RJD Series Analog Phone RJA-45 Operating Voltage 48, 220 VDC Digital Phone RJD-45 Clamping Voltage 55, 280 VDC Operating Current 0.15A Part Number Peak Surge Current Frequency Range Insertion Loss SPD Technology Connection Type Operating Temperature Dimensions (Inches) Weight Certifications 200 A (10 x 1000 μs) 0 to 50 MHz < 0.1 dB at 50 MHz Silicon Breakover Devices w/Series PTC RJ-45 Jacks -40°C to +85°C 1.0H x 2.5W x 4.25L 3 oz UL 497A, CUL, ISO 9001:2000 Caution: The Edco RJA and Edco RJD Series are intended for indoor use only and shall be employed on the equipment side of a listed primary telephone protector. 28 Highway Lighting Edco SHA Series Highway Lightning Protection The SHA Series provides surge protection for highway lighting/street pole applications. The suppressor is encapsulated in a weatherproof enclosure that is installed right inside the pole. The SHA Series is available in 120V, 240V, 277V and 480V Single Phase models. In addition, optional Low Capacitance (LC) and Both Black leads (BB) models are offered. Features ■ Weatherproof ■ Solid-state design ■ No follow current ■ Various options available ■ Line-to-ground protection ■ 5 year warranty ■ Neutral-to-ground protection General Technical Specifications Part Number Installation Edco SHA-Series Operating Voltage 120, 240, 277, 480 VAC Clamping Voltage 395, 710, 850, 1500 VAC Operating Current NA Total Peak Surge Current Black L1 IN To Source 47-63 Hz EMI Attenuation NA SPD Technology MOVs Modes of Protection L-G, N-G Status Indication NA Connection Type Leads Operating Temperature -40°C to +85°C Dimensions (Inches) 0.8H x 2.875W x 5.3L Weight 1 lb Certifications ISO 9001:2000 White L2 IN GAUGE COLOR CONNECTION 22" 6 GREEN GROUND 12" 10 BLACK L-1 (HOT) 12" 10 WHITE L-2 (NEUTRAL OR HOT) SHA Series L2 OUT White Caution: Installation and service of this product should be performed by qualified personnel only. Models Standard Special LEADS LENGTH To Ballast Green 39 kA Operating Frequency L1 OUT Black SHA-1203, SHA-2403, SHA-4803 SHA-2773 (Available upon request) SHA-4803BB (Both leads Black) SHA-_ _ _ _LC (Low Capacitance option) 29 Headquarters Surge Protection 328 Water Street Binghamton, NY 13901 T: 607-721-8865 T: 800-288-6169 F: 607-722-8713 E: contactsurge@emerson.com 1805 N.E. 19th Avenue Ocala, FL 34470 T: 352-732-3029 T: 800-648-4076 F: 352-867-1237 10020 E. Knox Avenue Suite 50 Spokane Valley, WA 99206 T: 509-777-2314 T: 800-953-3701 F: 509-927-0435 Emerson Network Power. The global leader in enabling Business-Critical ContinuityTM. EmersonNetworkPower.com AC Power Connectivity Embedded Computing Embedded Power Outside Plant Power Switching & Controls Racks and Integrated Cabinets Services DC Power Monitoring Precision Cooling Surge Protection Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co. While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. SL-50100 Rev.0 6/08 Printed in USA