IHSUNG TECH HIGHCONTRL & HIGHTECHNOLOGY ly-Lok ReliF Vallve IHSUNG TECH.CO.,LTD. Relief Valve CONTENTS ▣ Proportional Relief Valves shown ▣ Technical Data ……… 2 ……… 3 ~ 6 Pressure-Temperature Ratings Back Pressure Set Pressure and Resealing Pressure Materials of Construction Flow Data at 70°F (20°C) – Air & Water Dimensions 2 Relief Valve ▣ Proportional Relief Valves shown Plug Cap Spring Label Lock nut Lock wire hole Stem seal Stem O-ring End connections Relief valve shown Features ■ Service up to 250 psig (17.2 bar) ■ One spring for the full set pressure range ■ 1/2 in. and 12 mm end connections—IHRV series Operation relief valves OPEN when system pressure reaches the set pressure and CLOSE when system pressure falls below the set pressure. ■ High-pressure —select and install the spring that covers the required set pressure ; apply the matching label to the cap. ■ Low-pressure IHRV series—the spring is already installed. ※For valves not actuated for a period of time, initial relief pressure may be higher than the set pressure. 3 Relief Valve ▣ Technical Data Pressure-Temperature Ratings Item Relief valve Working Pressure at 70°F (20°C) 250 psig (17.2 bar) Set Pressure 10 ~ 250 psig (0.68 ~ 17.2 bar) Outlet Pressure 250 psig (17.2 bar) Seal Material Fluorocarbon FKM Temperature, °F (°C) –10 (–23) Neoprene Ethylene propylene Maximum Set Pressure, psig (bar) –40 (–40) –30 (–34) Buna N - - - -0 (-17) -10 (12) 25 (-4) 30 (-1) 50 (10) 150 (65) 250 (17.2) 250 (17.2) 250 (17.2) 250 (17.2) 200 (93) 250 (121) 275 (135) 300 (148) - ➀ The pressure-temperature ratings are based upon laboratory testing to ensure that the cracking pressure does not deviate by more than 20 % from the initial room-temperature set pressure. ➁ Outlet pressure should not exceed inlet pressure. Back Pressure System back pressure increases the set pressure of the valve. To compensate, multiply the back pressure by 0.8 and subtract the result from the desired set pressure. Use the result to pre-set the valve while back pressure is equal to atmospheric pressure. Example: Desired set pressure is 120 psig. System back pressure is 40 psig. Step 1. Multiply back pressure by 0.8. 40 psig * 0.8 = 32 psig. Step 2. Subtract result from desired set pressure. 120 psig – 32 psig = 88 psig. Step 3. Pre-set proportional relief valve to 88 psig. 4 Relief Valve Set Pressure and Resealing Pressure ■ Set pressure is the upstream pressure at which the first indication of flow occurs. Set pressure of each valve after initial relief is repeatable within ± 5 % at room temperature. ■ Resealing pressure is the upstream pressure at which there is no indication of flow. Resealing pressure is always lower than set pressure. Testing Every R series proportional relief valve is tested for set and resealing performance. Test Set Pressure psig (bar) Minimum Resealing Pressure as a Percentage of Set Pressure, % 10 to 20 (0.68 to 1.3) 50 175 to 250 (12.0 to 17.2) 94 Item Relief valve Materials of Construction 1 Plug 2 Cap 12 O-ring 3 Label 13 Insert 4 Lock nut 14 Seat retainer 15 Quad seal 5 Spring 16 Body 6 Spring support 7 Bonnet 8 Quad seal 9 O-ring 10 Retainer 11 Stem 5 Relief Valve Flow Data at 70°F (20°C) – Air & Water 6 Relief Valve Dimensions ➀ Dimensions are for reference only and are subject to change. End Connections Inlet Outlet Ordering Number Dimensions , in. (mm) A B C 38.7 37.3 104.6 46.7 114.0 35.7 103.0 32.2 99.5 35.7 103.0 1/4“ Iy-Lok 1/4“ Iy-Lok IHRV-04T 6mm Iy-Lok 6mm Iy-Lok IHRV-06M 8mm Iy-Lok 8mm Iy-Lok IHRV-08M 1/2” Iy-Lok 1/2” Iy-Lok IHRV-08T 12mm Iy-Lok 12mm Iy-Lok IHRV-12M 1/2” Male NPT 1/2” Iy-Lok IHRV-08NMT 1/2” Male NPT 12mm Iy-Lok IHRV-04NMT 1/4” Male NPT 1/4” Female NPT IHRV-04NMF 30.0 3/8” Male NPT 3/8” Female NPT IHRV-04NMF 34.5 1/2” Male NPT 1/2” Female NPT IHRV-04NMF 38.0 46.7 1.IHSUNG RELIF VALVE Ordering system 2.SIZE 04: 1/4” 08: 1/2” IHRV-08 N M 1 2 3 4 T 5 3.PIPE THREAD N: NPT R: PT 4,5. END TYPE M:MALE F:FEMALE T:TUBE O.D 7