exit/chicago - HE Williams

advertisement
CHICAGO-APPROVED EXIT LIGHT
CATALOG #:
TYPE:
PROJECT:
EXIT/CHICAGO
NOTES:
EXAMPLE
EXIT/CHICAGO
t
-
SERIES
SF
t
-
AC
t
-
NA
t
-
NUMBER POWERDIRECTIONAL
OF FACES
OPTIONS
ARROWS
OPTIONS
t
OPTIONS/
ACCESSORIES
CROSS SECTIONS
FEATURES
XX
13-11/16”
12-5/16”
2-5/16”
Shown with AC option
12-5/16”
Shown with EM option
ORDERING INFORMATION
SERIES
DIRECTIONAL ARROWS 1 (Must specify)
EXIT/CHICAGO
Chicago-Approved Exit Light
NUMBER OF FACES (Must specify)
SF
DF
Single face
Double face
POWER OPTIONS (Must specify)
AC
EM
Available as full-time AC powered unit or
emergency unit with battery backup.
6V maintenance-free sealed lead acid NiCd
battery provides 90 minutes of emergency
operation on EM units.
XX
Automatic, low voltage disconnect (LVD)
activates EM unit in event of partial power
failure or brownout.
XX
Charge rate/power on LED indicator and
built-in test switch on emergency units.
XX
Industry-standard white housing and red
letters on white glass lens.
XX
Unique design allows double face
conversion in the field.
XX
Fully automatic solid-state system on EM
units recharges battery in 24 hours.
XX
9-9/16”
AC operation (120V only)
AC operation with emergency battery backup
2-5/16”
See back for details
NA
No Arrows
DA
Double Arrows
RA
Right Arrow (for single face units only)
LA
Left Arrow (for single face units only)
LARA
Left/Right Arrow 2
ACCESSORIES (Shipped separately)
See back for details.
PC2 Polycarbonate shield
WG
Wireguard
1
2
H.E. Williams, Inc.
Carthage, Missouri
w w w.hew.com
417-358-4065
These units come standard with no directional
arrows. If directional arrows are required for
your application, it must be specified on all
orders.
For double face units that need to point in the
same direction (left/right) from both sides.
Emergency
Page 1 of 2
EXIT/CHICAGO
CHICAGO-APPROVED EXIT LIGHT
ELECTRICAL INFORMATION
SPECIFICATIONS
Housing – Durable, powder-coated 20-gauge
steel construction.
Lens – Open face glass panel with silkscreened letters.
Electrical – Universal voltage, 120 or 277
VAC operation (EM unit only). 120 volt, AC
unit.
Mounting – Mounting canopy for top or end
mount. Universal knockout pattern on back
plate for wall mount.
Labels – Listed to UL 924 standard as an exit
light suitable for dry or damp locations. Meets
NFPA 101 Life Safety Code, NEC, OSHA, Local
and State Codes.
Warranty – 5-year limited warranty
Input Watts (W)
Catalog Number
120V
Input Amps (A)
277V
120V
277V
EXIT/CHICAGO-AC
24
-
0.2
-
EXIT/CHICAGO-EM
26
26
0.24
0.24
ACCESSORIES
PC2
WG
FIXTURE DETAILS
Single Face
Double Face
NA
DA
RA
LARA
LA
Emergency
Page 2 of 2
H.E . W illiams, In c.
C ar t hage, Mis s our i
Information contained herein is subject to change without notice.
w w w.he w.c om
417- 3 5 8 - 4 0 6 5
HEW70152JL REV.06/30/16
Download