104406 Fire-Trol 2006 - Dean Lally LLC / Fire

advertisement
UL–Classified FIRE-TROL
Prefabricated Fireproofed
Columns speed construction,
reduce costs, improve quality
FIRE-TROL columns have provided the construction industry with a revolutionary type of fireproofing, which has been used in thousands of projects throughout the United States. Developed over four decades ago, still
nothing can compare to this unique product.
The FIRE-TROL column utilizes a method of pre-fireproofing structural
building columns that provides architects, engineers and contractors with
a durable, versatile, and aesthetically pleasing fireproofing option.
Certification of this product by Underwriters Laboratories Inc., assures
quality and acceptance throughout the country. Due to the column’s composite design, FIRE-TROL can provide one of the smallest and strongest
finished cross sections of any fireproofing method on the market.
The structural portion of the FIRE-TROL column is created from wideflange, pipe, or tube material meeting the latest ASTM grades and specifications and is completely fabricated in our U.L.
inspected facility. After the column is laid-out, it
receives its special architectural steel shell. The
size and shape of the steel shell is determined
by the fire resistance rating required, and the
architectural needs of the project. A two, three,
or four-hour fire resistance rating can be provided with different shell configurations. Our certified welders install all the required plates and
connections per the latest AWS codes. After all
welding is completed; the fireproofing insulation
is installed between the structural column and
the architectural shell. For pipe and tube
columns, a mixture of 5,000 p.s.i. concrete is
also added to the center of the column. After a
final cleaning and shop priming, the FIRE-TROL
column is shipped to the jobsite where it is erected in the same manner as an ordinary, unprotected steel column.
The rugged, low maintenance steel shell is the most distinctive feature of
the FIRE-TROL’s unique design. After a finished coat of paint, the column’s smooth steel surface will provide decades of service, with minimal
maintenance. Because the exposed parts of the column are painted
steel, it is suitable for both interior and exterior applications. Optional
zinc-rich primer, or hot dip galvanizing, further enhances the corrosive
resistant qualities of the architecturally exposed shell. Non-structural
items, such as window sash, door frames, or brick anchors can be simply
attached to the sides of the shell using mechanical fasteners or welding.
The same steel shell which gives the column its beauty, also provides
extreme durability and tamper resistance.
By pre-fireproofing the columns during shop fabrication, field labor and
time are reduced, while quality control is increased. There is no waiting
time for forms to be erected or wallboard to be installed. Delays caused
by inclement weather due to curing or drying times of plaster or concrete
are not factors associated with our columns.
The FIRE-TROL column provides an attractive and practical alternative
when architecturally exposed columns require a strong, clean and durable
fireproofing. They are the perfect solution when a design requires
exposed columns in schools, parking garages, warehouses, and correctional facilities. They are also extremely popular in religious, health care,
industrial, commercial, and some residential applications.
2
A
B
C
This is FIRE-TROL:
A prefabricated, fireproofed unit
consisting of a load-bearing steel
column (A), encased in a special
proprietary insulating material (B),
which is permanently protected by
an outer nonload-bearing steel
shell (C). FIRE-TROL columns are
rated and labeled by Underwriters’
Laboratories, Inc., for fire retardant classifications of 2,3, and 4
hours. Columns are completely
shop fabricated and shipped to
the job site ready to erect.
FIRE-TROL Columns...
Architecturally Preferred
Economically Installed for all
Types of construction
Abington Elementary School
Allied Beverage Warehouse
Big Spring High School
Boston Convention Center
Brandywine Town Center
Bridgewater State College
Bryant College
Cesar Chavez Elementary School
Christiana Core Center
CNSI at UCLA
Daniel Boone Middle School
Dell Children's Medical Center
Grinnell College
Home Depot
JFG Coffee
John Hopkins University
Kitsap County Convention Center
Lowes Home Improvement
Manchester Civic Center
Millbrook High School
National Archives
NCCU, School of Law
North Kingstown High School
Okaloosa Regional Airport
Pathmark
Platte Valley Medical Center
Residence of Fountain Square
Roosevelt Square
Rush Copley Hospital
San Mateo Youth Services
Science Center of Iowa
Self Memorial Hospital
Shelby County Detention Center
Southern State Correctional Facility
Super Stop & Shop
University of Cincinnati
Waterbury Performing Arts
Winona State University
YMCA
Abington PA
Mt Laurel NJ
Newville PA
Boston MA
Wilmington DE
Bridgewater MA
Smithfield RI
Eugene, OR
New Castle DE
Los Angeles, CA
Douglassville, PA
Austin, TX
Grinnell, IA
Aberdeen, MD
Knoxville, TN
Baltimore City MC
Seattle WA
Medford NY
Manchester CT
Raleigh, NC
Washington DC
Durham NC
No. Kingstown RI
Elgin AFB, FL
Staten Island NY
Brighton, CO
Lombard, IL
Chicago, IL
Aurora, IL
San Mateo, CA
Des Moines, IA
Greenwood SC
Shelbyville, KY
Cumberland NJ
Somers NY
Cincinnati, OH
Waterbury CT
Winona, MN
Green Bay, WI
3
FIRE-TROL Columns
UL RATED / FIREPROOFED PIPE COLUMNS
SQUARE SHELL (SO)
ROUND SHELL (00)
ROUND
TYPE OO
HW
XHW
XXHW
4”
HW
XHW
HW
41/2" XHW
XXHW
HW
51/2" XHW
XXHW
HW
65/8" XHW
XXHW
HW
85/8" XHW
XXHW
103/4" HW
XHW
123/4" HW
XHW
31/2"
Weight per Ft.
SQUARE
TYPE SO
Wall Thickness
OD of Pipe
CONCRETE FILLED STEEL PIPE
6
.216
.300
.600
.226
.318
.237
.337
.674
.258
.375
.750
.280
.432
.864
.322
.500
.875
.365
.500
.375
.500
15
17
23
20
22
24
27
36
36
39
52
49
56
73
81
91
111
123
133
169
178
45
58
94
58
75
73
93
155
106
139
230
144
197
327
232
314
475
342
423
442
534
ALLOWABLE SAFE LOAD IN KIPS*
Effective Length in Feet
KL with Respect to Radius of Gyration
8
10
40
49
79
53
66
66
86
139
99
130
215
139
188
312
225
305
460
336
415
437
526
32
39
60
45
56
59
76
122
92
120
198
132
178
293
218
295
444
328
406
429
517
12
36
46
51
65
102
85
110
178
123
166
272
210
283
425
320
394
421
507
14 16
18
20
22
X106
2 HOUR
24
26
41
52
75
98
156
114
153
249
201
270
404
311
383
412
496
66
84
132
104
140
225
190
257
383
300
370
402
484
54
69
93
125
198
179
242
359
289
356
391
470
81
109
169
167
226
334
277
342
380
457
Shell
Size
Wt.†
6x6
23
6x6
X104
3 HOUR
Shell
Size
X101
4 HOUR
X106
2 HOUR
X104
3 HOUR
X101
4 HOUR
Wt.†
Shell
Size
Wt.†
Shell
Size Wt.†
Shell
Size Wt.†
Shell
Size Wt.†
7x7
31
8x8
39
65/8
21
65/8
21
85/8
34
22
7x7
30
9x9
53
65/8
20
85/8
33
85/8
33
7x7
28
8x8
37
9x9
52
65/8
18
85/8
32
85/8
32
8x8
33
9x9
49
10x10
59
85/8
29
85/8
29 103/4
52
9x9
44
10x10
55
11x11
51
85/8
25
103/4
47 103/4
47
41
12x12
69
13x13
63
103/4 38
123/4
57 123/4
57
50
14x14
63
15x15
76
14
58
14
58
16
99
61
16x16
75 17x17
89
16
85
16
85
18
113
68
154
209
307
264
326
368
442
141
191
278
251
309
355
426
127
171 11x11
248
237 13x13
291
341 15x15
409
*Load Tables Based on Fy=36ksi
UL RATED / FIREPROOFED TUBE COLUMNS
SQUARE SHELL (SS)
ROUND SHELL (OS)
SQUARE
TYPE SS
3x3
31/2x31/2
4x4
5x5
6x6
ROUND
TYPE OS
7x7
8x8
10x10
4x2
4x3
5x3
6x3
6x4
7x5
RECTANGLE
TYPE RR
8x4
8x6
10x6
4
1
Weight per Ft.
Wall Thickness
OD of Pipe
CONCRETE FILLED STEEL PIPE
/4 15
/4 20
1
/4 25
3
/8 28
1
/4 36
3
/8 40
1
/2 44
1
/4 49
3
/8 55
1
/2 60
1
/4 65
3
/8 72
1
/2 78
1
/4 82
3
/8 90
1
/2 98
1
/4 122
3
/8 132
1
/2 142
1
/4 14
1
/4 19
1
/4 23
1
/4 27
1
/4 35
3
/8 39
1
/4 48
3
/8 54
1
/2 58
1
/4 45
3
/8 51
1
/2 57
1
/4 64
3
/8 70
1
/2 77
1
/4 78
3
/8 86
1
/2 93
1
ALLOWABLE SAFE LOAD IN KIPS*
X106
2 HOUR
Effective Length in Feet
KL with Respect to Radius of Gyration
6
8
10
12
62
77
98
132
137
185
229
178
241
299
221
297
369
266
357
440
364
482
592
43
73
89
102
130
176
173
232
289
163
219
274
217
291
361
255
341
424
53
68
89
119
128
172
212
169
228
283
213
285
354
259
346
427
357
471
579
27
60
74
87
119
158
163
218
270
147
199
247
208
278
345
244
326
405
40
55
78
102
118
158
194
160
215
267
204
273
337
251
334
412
349
460
566
42
65
85
107
141
173
150
200
248
194
259
320
240
321
395
340
448
550
45
57
67
106
140
151
201
248
131
176
215
196
262
325
232
309
381
46
89
117
137
182
223
112
148
181
184
245
303
217
289
356
14 16
51
64
94
124
150
138
183
226
183
243
301
231
306
377
330
435
533
73
92
123
160
196
89
118
142
170
226
277
202
277
328
18
20
22
24
26
28
40
80
103
124
125
165
204
171
227
279
218
291
355
320
419
515
64
82
110
145
177
158
208
255
206
272
334
308
404
495
105 86
137 111
165 131
66
155
204
250
183
243
298
138
181
221
164
217
264
95
124
151
143
189
230
193
254
311
296
388
474
79
101
128
168
204
178
236
286
282
369
453
111
146
176
163
215
259
267
350
428
94
123
146
192
231
252
331
403
128
168
201
236
308
375
X104
3 HOUR
X101
4 HOUR
X106
2 HOUR
X104
3 HOUR
Shell
Shell
Size Wt.† Size
X101
4 HOUR
Shell
Size
Wt.†
Shell
Size
Wt.†
Shell
Size
Wt.†
6x6
6x6
24
22
7x7
7x7
31
30
8x8
8x8
39
38
65/8
85/8
23
36
85/8
85/8
37
36
85/8
103/4
37
60
6x6
21
7x7
28
8x8
36
85/88
34
85/88
34
103/4
58
7x7
25
8x8
33
9x9
48
103/4
55 103/4
55
123/4
75
8x8
29
9x9
44
10x10
54
103/4
50 123/4
70
123/4
70
9x9
39
10x10
49
11x11
45
123/4
65 123/4
65
14
79
10x10 43
11x11
39
12x12
67
14
73
16
118
16
118
12x12 52
13x13
47
14x14
59
16
100
18
133
18
133
61/2x41/2
7x5
7x5
8x5
15
22
21
17
71/2x51/2
7x6
8x6
9x6
20 81/2x61/2
19
8x7
28
9x7
23 10x7
27
30
42
30
8x6
25
9x7
38
10x8
42
9x7
34
10x8
38
11x9
37
10x6
29
11x7
28
12x8
54
10x8
32
11x9
32
12x10
43
12x8
43
13x9
37
14x10
48
Wt.†
Shell
Size Wt.†
67
120
157
191
144
189
230
100
130
156
121
159
191
† Weight shown in pounds per foot for shell and fireproofing only
80
97
**Load Tables Based on Fy=46ksi
05100/FIR
BuyLine 3154
TYPE SH
and RH
UL RATED / WIDE FLANGE SHAPES
X106
X104
2 HOUR
3 HOUR
WF SIZE
Shell
Shell
Size
Wt.†
Size
Wt.†
W4x13
6x6
28
7x7
37
W5x16
7x7
37
8x8
45
41
W6x15, 20, 25
8x8
45
81/2x81/2
W8x18, 21,24,28,31
10x10
72 101/2x101/2 59
W8x35, 40, 48
10x10
72 101/2x101/2 59
W8x58, 67
101/2x101/2
59
11x11
67
W10x22
12x71/2
51 121/2x8
53
W10x26, 30
12x71/2
51 121/2x8
53
W10x33, 39
111/2x91/2
59
12x10
67
W10x45
12x91/2
63 121/2x10
69
W10x49
111/2x111/2
72
12x12
87
W10x54, 60, 68
12x12
87 121/2x121/2 83
W10x77, 88
121/2x121/2
83
13x13
89
W10x100,112
13x13
89 131/2x131/2 95
W12x26, 30, 35
14x8
63 141/2x81/2
69
W12x40, 45
131/2x91/2
71
14x10
95
W12x50
14x10
95 141/2x10
78
W12x53
131/2x111/2
83
14x12
89
W12x58
14x111/2
85 141/2x12
92
W12x65, 72, 79, 87
14x14
102 141/2x141/2 108
W12x96, 106
141/2x141/2 108
15x15
115
W12x120, 136
15x15
115 151/2x151/2 122
W12x152, 170
151/2x151/2 122
16x16
129
W12x190
16x16
129 161/2x161/2 136
WF SIZE
TYPE OH
W4x13
W5x16, 19
W6x15, 20
W6x25
W8x18, 21
W8x24, 28
W8x31
W8x35, 40, 48
W8x58, 67
W10x22, 26, 30
W10x33, 39, 45
W10x49, 54
W10x60, 68, 77
W10x88, 100
W10x112
W12x26, 30
W12x35
W12x40, 45, 50
W12x53, 58
W12x65, 72, 79
W12x87, 96, 106
W12x120, 136
W12x152, 170
W12x190
UL RATED / WIDE FLANGE SHAPES
X106
X104
2 HOUR
3 HOUR
Shell
Shell
Size
Wt.†
Size
Wt.†
5
8 /8
40
85/8
40
85/8
40
103/4
64
103/4
64
103/4
64
103/4
64
123/4
84
123/4
84
123/4
84
123/4
84
123/4
84
14
98
14
98
14
98
14
98
14
98
16
142
14
98
14
98
16
142
16
142
16
142
18
183
18
183
18
183
18
183
18
183
18
183
18
183
16
142
16
142
16
142
18
183
18
183
18
183
18
183
18
183
20
203
20
203
20
203
20
203
20
203
22
238
22
238
22
238
22
238
22
238
X101
4 HOUR
Shell
Size
8x8
9x9
9x9
11x11
11x11
111/2x111/2
13x81/2
13x81/2
121/2x101/2
13x101/2
121/2x121/2
13x13
131/2x131/2
14x14
15x9
141/2x101/2
15x101/2
141/2x121/2
15x121/2
15x15
151/2x151/2
16x16
161/2x161/2
17x17
Wt.†
45
61
61
67
67
72
61
61
72
75
83
89
95
102
74
83
84
95
98
115
122
129
136
144
X101
4 HOUR
Shell
Size
Wt.†
85/8
40
103/4
64
123/4
84
123/4
84
123/4
84
14
98
14
98
16
142
16
142
16
142
16
142
18
183
18
183
18
183
20
203
18
183
18
183
18
183
20
203
20
203
22
238
22
238
22
238
22
238
†Weight shown in pounds per foot for shell and fireproofing only.
All shell sizes are shown in inches.
Information available upon request for sizes other than shown.
Refer to latest edition of A.I.S.C. steel construction manual for allowable safe loads.
5
Design considerations
Column design data
Materials
Load bearing members as specified by the engineer typically conform to the following grades:
FIRE-TROL columns are designed
in accordance with the latest specifications of the America Institute of
Steel Construction and the
American Concrete Institute.
Minimum covering of fire-proofing
is in accordance with the minimum
hourly rating requirements established by Underwriters’
Laboratories, Inc. All structural
steel used in the core conforms to
ASTM Specifications. Concrete
filling for pipes or tubular sections
is of a 5000 p.s.i. mix. The outer
shell, sash stops, curtain wall connections and other special features
are provided in accordance with
the architect’s details. Welded shop
and field connections are in strict
conformance with the current
requirements of AISC. Columns
are given one shop coat of standard metal primer unless otherwise
specificed. FIRE-TROL columns
are readily adaptable to single or
multi-story structures of conventional, traditional, or contemporary
design...and with any combination
of materials.
A complete selection of load-bearing column types is available with
exterior shells in round, square,
and rectangular shapes. The round
exterior shells are Type OO, OS,
and OH. The square and rectangular exterior shells are Types SH,
RH, SO, SS, and RR.
FIRE-TROL columns meet the
requirements of local, state, national, and federal codes governing
fire-resistive construction. Each
FIRE-TROL column is fabricated in
conformance with the requirements
of Underwriters’
Laboratories,
Inc., and bears
a UL label
certifying compliance with
requirements
as stated in
their directory.
6
Specifications (Cont’d)
Wide Flange: A992
HSS (Hollow structural sections): A500
Grade B, A500 Grade C
Pipe; A53B (welded), A106B
(Seamless).
In instances where the core is a
pipe or tube, FIRE-TROL columns
are always filled with high strength
concrete that shall attain an ultimate compressive strength of 5000
p.s.i. in 28 days.
Shop Drawings
Shop drawing shall give complete
details necessary for the fabrication of the individual columns and
must be approved in writing by the
Architect, Engineer, or Structural
Steel Contractor before fabrication
is started.
Fire Rating
All FIRE-TROL columns shall bear
the label of Underwriters’
Laboratories, Inc. for the inspection manifest and the hourly fire
rating specified herein.
Specifications
Scope
These specifications cover the
design, fabrication, and erection of
FIRE-TROL prefabricated, fireproof
steel columns.
Design
Design, manufacture, and fabrication of FIRE-TROL prefabricated,
fireproofed steel columns shall be
in accordance with specifications of
Dean Lally LP as well as latest
specifications of American Institute
of Steel Construction, and
American Concrete Institute.
Minimum covering of fire-proofing
shall be in accordance with minimum hourly rating requirements
established by Underwriters’
Laboratories, Inc. (R-3966-2-3-4)
Connections
Welded shop or field connections
shall be in strict conformance with
ANSI/AWS D1.1 latest revision.
Bolted or riveted shop connections
shall be in strict conformance with
the American Institute of Steel
Construction.
Painting
All columns shall receive one shop
coat of standard metal primer
unless otherwise specified. All
loose mill scale, dirt, rust and other
foreign materials shall be removed
before priming coat is applied.
Handling and Erection
All FIRE-TROL columns shall be
erected in accordance with the latest requirements of the American
Insitute of Steel Construction.
Reasonable care shall be taken
not to damage or disfigure protective shells on FIRE-TROL
columns.
Engineering detail drawings
FOR ADDITIONAL
INFORMATION CALL
800-323-5514 NATIONWIDE
FIRE TROL
COLUMNS
DEAN LALLY L.P.
7
FIRE TROL
C O L U M NS
Manufactured By:
Dean Lally L.P.
Phone: 800-323-5514
email: fire-trol@deanlally.com