Tektronix MBD: Products > Handheld Digital Multimeters DMM 249

advertisement

DMM 249.

Features

Specs

Ordering Information

Pricing Information

Request a Quote

Handheld Digital Multimeters

DMM 249

CHARACTERISTICS

DC Volts

Range

300 mV

3 V

30 V

300 V

1000 V

Resolution

0.1 mV

1 mV

10 mV

100 mV

1 V

Accuracy:

±(0.3% of rdg + 2 cts).

Input Impedance: 10 megaohm paralleled by < 100 pF.

Overload Protection: 1100 VDC or VAC peak-topeak.

AC Volts

Range

3 V

30 V

300 V

750 V

Resolution

1 mV

10 mV

100 mV

1 V

Frequency Response:

3 V range: 40 to 300 Hz;

Other ranges: 40 Hz to 1 kHz.

Accuracy: ±(1.3% of rdg + 3 cts).

Input Resistance: 10 megaohm paralleled by < 100 pF.

Overload Protection: 1100 VAC peak-to-peak.

DC Current

Range

300 µA

3 mA

30 mA

300 mA

20 A

Accuracy:

300 µA: ±(1% of rdg + 2 cts).

3 mA: ±(1.2% of rdg + 2 cts).

30 mA: ±(1% of rdg + 2 cts).

300 mA: ±(1.2% of rdg + 2 cts).

20 A: ±(2% of rdg + 3 cts).

Burden Voltage:

Resolution

0.1 µA

1 µA

10 µA

100 µA

10 mA

300 µA, 30 mA: 200 mV max;

3 mA, 300 mA, 20 A: 2 V max.

Overload Protection: mA ranges: 1 A (600 V) fast-blow fuse;

20 A range: 15 A (600 V) fast-blow fuse.

AC Current

Range

300 µA

3 mA

30 mA

300 mA

20 A

Resolution

0.1 µA

1 µA

10 µA

100 µA

10 mA

Accuracy:

300 µA, 3 mA, and 30 mA ranges: ±(1.5% of rdg + 4 cts).

300 mA: ±(2% of rdg + 4 cts).

20 A: ±(2.5% of rdg + 5 cts).

Burden Voltage:

300 µA, 30 mA ranges: 200 mV max;

Other ranges: 2 V max.

Frequency Response: 40 Hz to 1 kHz.

Overload Protection: mA ranges: 1 A (600 V) fast-blow fuse;

20 A range: 15 A (600 V) fast-blow fuse.

Resistance

Range

300 Ohm

3 kilohm

30 kilohm

300 kilohm

3 megaohm

30 megaohm

Resolution

0.1 Ohm

1 Ohm

10 Ohm

100 Ohm

1 kilohm

10 kilohm

Accuracy:

300 Ohm: ±(1.2% of rdg + 4 cts).

3 kilohm, 30 kilohm, and 300 kilohm ranges: ±(1.0% of rdg + 2 cts).

300 megaohm: ±(1.5% of rdg + 3 cts).

30 megaohm: ±(2.5% of rdg + 5 cts).

Overload Protection: 600 VDC/AC RMS.

Test Voltage (open circuit): approximately equal to

1.3 V.

Continuity

Buzzer sounds if resistance < 30 Ohm.

Input Protection: 600 VDC/AC RMS.

Diode Test

Max Test Current: 1.5 mA.

Test Voltage (open circuit): 3.3 V.

Resolution: 1 mV.

Input Protection: 600 VDC/AC RMS.

Safety

UL1244, CSA231, EN61010-1.

Physical Characteristics

Dimensions

Length

Width

Depth

Net Weight with battery with holster mm

192

95

50 kg

0.36

0.56

Display: 3200 count LCD.

Sampling Rate: 2 S/s for digital display; 12 S/s for analog bar graph.

Operating Ambient Temperature: 0 to 50°C (0 to

80% R.H.).

Automatic Power Off: After 10 minutes.

Power Supply: 9 V battery.

Battery Life: 350 hours typical (alkaline).

in.

7.5

3.7

1.9

lb.

Top of Page

Features

Specs

Ordering Information

Request a Quote

Product manufactured in ISO 9001 registered facilities

49A-10733-3p481, 06/1997, 09/01/1999

Email this page URL for Favorites Printable page

Tektronix Site

Home | Products | Support | Sitemap | Search | Privacy Policy

© Copyright Tektronix, Inc | webmaster@tek.com