INNOVOLT H1000
USER GUIDE
SOLUTION OVERVIEW
OUR INDUSTRIAL SOLUTION
The single most important way to minimize downtime is
to prevent machinery malfunctions. With equipment that
regularly breaks down or jams impacting the bottom line
through the costs of lost production, lost capacity, repairs
and wasted labor, industrial environments are demanding
a comprehensive solution to solve these costly issues and
ensure the reliability of equipment. Some have been able
to pinpoint the cause to fluctuations in the electricity that
powers these sensitive machines while others speculate or
are just left wondering what the culprit is. Regardless of
the ability to diagnose the problem, all companies have
one thing in common—a desire to prevent downtime.
Innovolt’s H1000 power protection device represents an
evolution of a core technology that has proven to be
superior to any other on the market. This line has been
redesigned from the ground up to be more compact
and reliable. The standard terminal strip is provided for
hardwired AC IN/OUT and makes this appliance perfect
for NEMA cabinet mount applications, or for embedding
inside stand-alone industrial or commercial products.
Housed in a compact 4” x 5” footprint, this appliance
comes standard with 35mm DIN rail mounting hardware.
Flip-out tabs are also provided for surface mount
applications. In addition, the diagnostic capabilities have
been improved to include real-time-clock based time
stamping as well as N-G voltage sensing. This device also
features EMI/RFI filtering as well as dry relay contacts to
signify presence/loss of AC output power.
HOW WE SOLVE THE PROBLEM
Innovolt combines patented electronics protection
technology with complete monitoring, management and
analytics software applications to intelligently protect and
optimize the performance of sophisticated electronics
allowing you to:
• Utilize patented technology to protect your equipment
• Prevent costly maintenance issues before they negatively impact your business
• Maximize equipment reliability, performance and lifespan
OUR TECHNOLOGY
More than twenty years ago, we began analyzing
power anomalies and the damage these could cause
to electronic devices. Through these efforts and
continued innovation, we developed Innovolt ROC™, our
microprocessor-based technology that provides Remote
Optimization and Control. This solution uses a series of
patented algorithms and protocols to recognize potential
power concerns and remediate issues before damaging
effects occur.
FEATURES
• Microprocessor based power protection algorithm
• Industry leading defense against current inrush resulting from voltage sags & brownouts
• Catastrophic overvoltage protection
• Post-blackout reclose sequence protection
• 3-Stage MOV protection against voltage surges
• 2nd order EMI/RFI filtering
• Real-time clock (RTC) based time stamping of disturbance events
• Status LEDs and dry contacts for remote signaling
• Source fault indication: L-N reverse polarity, missing GND and N-G voltage detection
• Compatible with Innovolt’s Power Doctor SmartPhone Adaptor and Power Doctor II optical reader accessories
• Cloud management platform
TECHNICAL INFORMATION
Order # H1000-20-120
PARAMETER
Nominal Operating Voltage
H1000-20-120
120V 60 Hz, single phase
Maximum Continuous Operating Voltage
(MCOV)
127V
Maximum Continuous Current
20 A
Peak Surge Current Capability
45,000 A
Protection
Weight
Dimensions
Mounting
Signaling Contacts
Microprocessor based
1.5 lbs.
4.4” H X 5.3” W X 3.5” D
DIN or Surface (DIN assembly removable)
Form C
Overvoltage Threshold
146V (+/- 2V)
Undervoltage Threshold
88V (+/- 2V)
Surge Protection
3-stage MOV
EMI / RFI Filtering
-35 dBmin
(100 kHz to 50 MHz)
VPR
Operating Temperature
Certifications
500V L-N , 600V L-G N-G
-25° - 50°C
derate linearly to 75% @ 70°C
UL 1449 3rd Edition, Type 4 SPD
UL 1283 5th Edition
CUL Recognized
RoHS Compliant
LED INDICATION
PWR/DATA
Green LED ON
• AC line voltage within normal limits
• Optical Data download possible with
Power Doctor 2 or PDSA-100 optical
reader (sold separately)
Green LED Flashing
• Device initialization
Voltage Sag
Red LED Flashing
• Flashes for 1 hour after recovery from a
Voltage Sag
Red LED ON
• Load is isolated
Overvoltage/Brownout
MOV Fail
Red LED Flashing
• Will flash for 1 hour following a recovery
from an Overvoltage/Brownout
Red LED ON
• MOV Damaged (replace device)
Green LED ON
• LNG connected correctly
GND – Source Fault
Red LED Single Flash
• Line – Neutral Reverse Polarity
Red LED Double Flash
• Loss of Ground
Red LED Triple Flash
• Neutral – Ground Voltage present
* When the MOV indicator light is ON, there is the potential that the device is no longer protecting against surge and should be replaced.
DIMENSIONAL DRAWINGS
DIMENSIONAL DIAGRAM - IN [mm]
3.52
[89,52]
5.38
[136,53]
3.21
[81,52]
4.44
[112,65]
DIN RAIL MOUNTABLE
DIMENSIONAL DIAGRAM - IN [mm]
5.68
[144,27]
3.21
[81,52]
5.38
[136,53]
4.44
[112,65]
WALL MOUNTABLE
COMPETITIVE LANDSCAPE
Innovolt H1000
Typical Competitor
Voltage Sag
U
–
Overvoltage
U
–
Undervoltage (Brownout)
U
–
Power Outage
U
–
Voltage Surge
U
U
EMI/RFI Filtering
U
U
MOV Life Indication
U
–
Ground Missing Indication
U
–
Neutral-Ground Fault Indication
U
–
Reverse Polarity Indication
U
–
V AC
120 (1-phase)
120 (1-phase)
kA
45
45
Time-stamped Disturbance Types & Totals
U
–
U
–
U (status, alarm, MOV life)
U (status)
U
U
Protection / Notification
Electrical Data
Nominal Operating Voltage
Total Surge Capability
Analysis
Signaling / Connectivity
Optical Data Output
LED Indicators
Relay contacts to signify power OFF
DATA COLLECTION
INNOVOLT MANAGEMENT CLOUD
Power Disturbances
IMC will be able to display the disturbance and source
fault data for the H1000 in both a visual (graphs) and
tabular format. Users will also be able to:
• Voltage Sag with timestamp
• Onset and recovery from Brownout with timestamps
• Onset and recovery from Blackout with timestamps
• Onset and recover from Overvolt with timestamps
• Onset of Surge with timestamp
• MOV status
Source Faults
• Onset and recovery from Loss of Ground
• Onset and recovery from Excess Neutral-Ground Voltage
• Onset and recovery from Line-Neutral Reverse Polarity
Power Doctor/Power Doctor SmartPhone Apaptor
The H1000 can be read by the Power Doctor II and the
PDSA-100 to download the collected power data. The
data can be uploaded from the Power Doctor to the
Innovolt Management Cloud using the Power Doctor V
application on a Windows PC.
• Indicate the location of the appliance
• Name the appliance
• Show both read (when someone read the device with a Power Doctor or PDSA and event data (disturbances with timestamps)
• Add a description of the appliance
• Control which user(s) can view and modify the appliance
• Search for appliances based on any of the above information and event/fault data
• Share appliances with another party (e.g. another company that may be interested in the data from
the appliance)
Power Doctor allows a user to:
• View event data with timestamps
• View source fault data with timestamps
• View model number
• View Serial number
With and iPhone or Android*, the PDSA allows users to:
• View event data with timestamps
• View source fault data with timestamps
• View model number
• View Serial number
• Add location and description information
This product guide is intended to illustrate Innovolt’s product. For warranty related information and terms and conditions for purchase please contact Innovolt directly.
It will be important to note that the firmware on the H1000 can only hold 40 disturbances or source faults with timestamps at a time. Once it reaches the limit
it begins writing over the older events as new ones come in. The disturbance counters will continue to keep track of all the events that happen, but some of
them may not have timestamps due to the limit.
*Samsung Galaxy S3, Samsung Galaxy S4, Samsung Galaxy Note 2, Samsung Galaxy Note 3
About Innovolt
Innovolt’s Intelligent Electronics Management platform combines patented sensor technology with comprehensive analytics software
to safeguard and optimize the performance, productivity and usable life of essential electronic equipment in industries such as
information technology, medical, industrial automation and gaming. Through the remediation of power disturbances and a cloudbased management dashboard, customers achieve improved equipment uptime, lower repair costs and increased revenue. Currently
protecting an installed base of more than 250,000 electronic assets, Innovolt technology has to-date remediated against more than 170
million power disturbances to ensure the sustainable performance of electronic assets, consistently proving its value and delivering
millions of dollars in savings to our customers. For more information, visit www.innovolt.com.
1.404.467.6368
info@innovolt.com
www.innovolt.com
Copyright © Innovolt, Inc. All rights reserved.
H1000-PG-7-30-14