Interchangable Cartridge TEVs

advertisement
Type
INTERCHANGEABLE CARTRIDGE TEVs
CONVENTIONAL
PORT
BODY
EQ
QE
Q
BALANCED
PORT
®
COMPONENT ASSEMBLY
SQE
SQ
EQE
&
Type
4 mm Allen
Wrench (AW-1)
3
2
SAE
(Internally
Equalized)
ODF
(Internally
Equalized)
SAE
(Externally
Equalized)
BQ
BQE
EBQ
ODF
(Externally
Equalized)
ODF
(Internally
Equalized)
ODF
(Externally
Equalized)
Attach cartridge
identification tag to
element capillary tube.
SBQE
SBQ
EBQE
1
2
Turn clockwise until seated
(do not over tighten).
(Oil) Lubricate O-rings.
Thermostatic
Element
5
4
SAE
(Externally
Equalized)
SAE
(Internally
Equalized)
ODF
(Internally
Equalized)
CARTRIDGE
Top surface is color coded
to identify cartridge capacity
Capacity code
on cartridge
SPORLAN
0
ODF
(Internally
Equalized)
NOMINAL CAPACITY (tons) of the Valve to be REPLACED
R-22
R-134a
R-401A
R-402A
R-404A
R-502
R-507
1/8
1/4
1/8
1/8
1/8
1/8
1/8
1/8
1/6
1/3
1/6
1/6
1/6
1/6
1/6
1/6
1/4
1/4
1/4
1/4
1/4
1/2
3/4
SIZE
COLOR CODE
0
RED
1/4
1
YELLOW
1/2
1
1/2
1/2
1/2
1/2
1/2
1/2
2
GREEN
1
1-1/2
1
1
1
1
1
1
3
BLUE
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
4
PINK
2
2
2
2
5
BLACK
3
3
3
3
6
WHITE
2
2-1/2
2
3
2
2
2-1/2
4
2-1/2
2-1/2
3
5
3
3
NOMINAL CAPACITY (tons) of the Valve to be REPLACED
Identification tag with cartridge code
(bends around capillary tubing)
SPORLAN
AAA
Capacity code
on cartridge
ELEMENT
Element Size
Number
*Refrigerant
Code
GA
Thermostatic
Charge
*While many new refrigerants and refrigerant blends have a unique
letter code, many use the same thermostatic element as the traditional
refrigerant they replace. Refer to the table at right to select the correct
thermostatic element.
© 2011 Sporlan Division, Parker Hannifin Corporation
R-402A
R-404A
R-410A
R-502
R-507
SIZE
COLOR CODE
1/8
thru
1/5
1/8
thru
1/3
1/8
thru
1/5
1/8
thru
1/5
1/8
thru
1/5
1/8
thru
1/5
1/4
thru
1/3
1/8
thru
1/5
1/8
thru
1/5
AAA
RED
1/4
thru
1/3
1/2
thru
2/3
1/4
thru
1/3
1/4
thru
1/3
1/4
thru
1/3
1/4
thru
1/3
1/2
thru
3/4
1/4
thru
1/3
1/4
thru
1/3
AA
YELLOW
1/2
thru
1
3/4
thru
1-1/2
1/2
thru
1
1/2
thru
1
1/2
thru
1
1/2
thru
1
1
thru
1-3/4
1/2
thru
1
1/2
thru
1
A
BLUE
1
1-1/4
thru
1-3/4
1-3/4
thru
3
1-1/4
thru
1-3/4
1-1/4
thru
1-3/4
1-1/4
thru
2
1-1/4
thru
2
2
thru
3-1/2
1-1/4
thru
2
1-1/4
thru
2
B
PINK
Attach cartridge
identification tag to
element capillary tube.
2
thru
3
3-1/4
thru
5-1/2
2
thru
3
2
thru
3
2-1/4
thru
3
2-1/4
thru
3
4
thru
6
2-1/4
thru
3
2-1/4
thru
3
C
WHITE
AIR
CONDITIONING
-
Before
After
Bench Flange
(QVT-F)
BQ VALVE CARTRIDGE
R-401A
COMMERCIAL
REFRIGERATION
50°F to – 10°F
Z
2
COMPONENT ASSEMBLY
R-134a
APPLICATION
Element Label
-
1
Q-Valve Tool
(QVT-1)
After hand tight, turn element clockwise 60°
(or movement equal to one hex flat).
R-22
Bulb
45
View of Element
Q-Valve Tool
(QVT-1)
AA
A
3
2
(Oil) Lubricate pushrods
and O-rings.
BQ Cartridge
Tool
Turn clockwise while applying downward force.
Thermostatic
Element
6
2710
R-410A
KT-45-ZGA
E CO • WASHIN
ALV
GT
NV
ON
LA
,M
OR MADE IN
O
U.S. of A.
SP
Abbreviation for
"Kit"
-
60°
RECOMMENDED THERMOSTATIC ELEMENTS
Capillary Tube Length
(standard = 5 ft.)
KT
Hand tighten element.
6
R-12
Note: BQ cartridge AA, A, B and C are also available with 15% bleed for R-22 and R-410A.
Date Code (by week and year of manufacture)
45
ZGA
(Oil) Lubricate lock ring
surface and top of
pushrods.
Q VALVE CARTRIDGE
R-12
1-1/2
Top surface is color coded
to identify cartridge capacity
ODF
(Externally
Equalized)
60°
1/4
Identification tag with cartridge code
(bends around capillary tubing)
ODF
(Externally
Equalized)
LOW
TEMPERATURE
REFRIGERATION
0°F to – 40°F
REFRIGERANT
12
X
–
–
–
–
–
X
–
–
–
X
X
–
–
–
–
22
–
X
X
–
–
–
–
X
–
–
–
–
X
X
–
–
134a 401A 402A 404A 407A 407C 408A 409A 410A 502
X
X
–
–
–
–
–
X
–
–
–
–
–
–
X
X
–
–
–
–
–
–
–
–
X
X
–
–
–
–
–
–
–
X
–
–
X
–
–
X
–
–
–
–
–
–
–
–
–
X
–
–
–
–
–
–
–
–
–
X
X
X
–
–
–
–
–
X
–
–
–
–
–
–
X
X
–
–
–
–
–
–
–
X
–
–
X
–
–
X
–
–
X
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
X
–
–
–
–
–
–
–
–
–
X
–
–
–
–
–
–
–
X
X
–
–
X
–
–
X
–
–
X
X
–
–
X
–
–
X
507
–
–
–
–
–
–
–
–
–
X
–
–
–
–
X
X
THERMOSTATIC
ELEMENT
KT-43-FCP60
KT-43-VCP100
KT-43-VGA
KT-43-SCP115
KT-45-ZGA
KT-45-ZCP180
KT-43-FC
KT-43-VC
KT-43-SC
KT-43-PC
KT-43-FZ
KT-43-FZP
KT-43-VZ
KT-43-VZP40
KT-43-SZ
KT-43-SZP
SYSTEM MOP
psig
50
90
–
105
–
170
–
–
–
–
–
12
–
30
–
35
The Sporlan type ZP thermostatic charges have essentially the same characteristics as the conventional
Z cross charges with one exception: they produce a pressure limit or MOP. The ZP charges are not
intended as replacements for the Z charges - they should only be used where a definite pressure limit is
required to prevent overloading the motor.
5
4
(Oil) Lubricate lock ring
surface.
Turn clockwise until
seated (do not over
tighten).
Hand tighten element.
60°
60°
7
Q-Valve Tool
(QVT-1)
View of Element
1
2
Before
After
Q-Valve Tool
(QVT-1)
Bench Flange
(QVT-F)
After hand tight, turn element clockwise 60°
(or movement equal to one hex flat).
Form 10-165 / 42011