AC/DC Power Supply Single Output The BW-series is an open frame board with an optional cover. Simplified circuit design enabled cost optimisation and miniaturization. Safety design is applied to UL, CUL and VDE. Features Wide input voltage range (85-264Vac) High efficiency & reliability Output voltage +/-10% Warranty: 2 years Possible applications Process control Office equipment Computer peripherals Telecommunications Industrial electronics & machines Mechanical features Control features Dimensions (WxLxH): 50x105x20mm Over voltage protection: Output shutdown Weight: 73g Over current protection: Current limiting, auto recovery Connector: JST connectors Closed or open frame type Optional: Wire harness for JST connectors (add –WH) Cover (add –P) Standards Safety: EMI : UL: UL60950; C-UL: CSA C22.2 No.60950; VDE: EN60950; IEC60950; VDE 805 EN 55022 ClassB; FCC Part 15-B ClassB; VCCI ClassB ETA-POWER EUROPE LTD., Sennweidstr.45, 6312 Steinhausen, Switzerland Phone: +41 41 747 01 11, Fax: +41 41 747 01 22 E-Mail: sales@etapower.com, www.etapower.com Specifications<AC/DC> BWS**SX-U 10WATTS / SINGLE Input Characteristics Input Voltage Input Current Input Range Input Frequency Input Frequency Range Phase Inrush Current *1 Efficiency [%] (typical) *2 Output Characteristics Output Voltage [V] Output Current [A] Voltage Adjust Range Ripple and Noise [mVp-p](maximum) *3 Regulation a.Statistic Line Regulation [mV](maximum) b.Statistic Load Regulation [mV](maximum) c.Temperature Coefficient *4 d.Drift[mV] (maximum) *5 e.Dynamic Load Regulation [mV](typical) f. Recovery Time Rise up time Hold up time Functions Over current Protection *6 >110% of Rated Output Current[A] Over voltage Protection >115% of Rated Output Voltage[V] Remote Sense Remote On/Off Environmental Operating Temperature *7 Operating Humidity Storage Temperature Storage Humidity Withstanding Voltage Insulation Resistance Vibration Shock Cooling Leakage Current Line Conducted Noise Safety Weight (typical) MTBF [H] Switching Frequency[kHz](typical) *8 Model BWS-3.3SX-U 66 3.3 2.0 83 26.4 29.7 31.5 BWS-05SX-U BWS-12SX-U BWS-15SX-U AC100-230V 0.3A at AC100V / 0.15A at AC230V AC85-264V (DC110-370V) 50/60Hz 47-440Hz Single 15A(maximum) at AC100V / 35A(maximum) at AC230V 74 80 80 5 12 15 2.0 0.9 0.7 +/- 10% of Rated Output Voltage(at no load within the input range) 100 170 200 40 45 96 120 108 135 0.03%/°C 40 75 90 not specified not specified 200mS(maximum) at 25°C and rated input/output 20mS(typical) at 25°C and rated input/output 2.2 2.2 3.8 5.75 Current Limiting with automatic recovery 0.99 Zener diode clamping 13.8 not available not available ETA-POWER EUROPE LTD., Sennweidstr.45, 6312 Steinhausen, Switzerland Phone: +41 41 747 01 11, Fax: +41 41 747 01 22 E-Mail: sales@etapower.com, www.etapower.com 81 24 0.5 290 192 216 135 0.77 0.55 17.3 27.6 Open board type:-10 to +50°C (-30 to +70°C) / enclosed type: -5 to +40°C 20 to 85%RH(non-condensing) -20 to +85°C 20 to 85%RH(non-condensing) Primary-Secondary AC3,000V for 1minute Primary-Frame Ground AC2500V for 1minute Secondary-Frame Ground AC500V for 1minute Primary-Secondary-Frame Ground 100MΩ(minimum) by DC500V insulation tester 5-10Hz:10mm double amplitude,10-55Hz:19.6m/s2,20minutes, period for 60minutes each along X,Y,Z axes(non-operating) 294m/s2 Convection 0.75mA (maximum) at 25°C,rated input/output and rated input frequency FCC Part15-B Class B VCCI Class B EN55022 Class B UL: UL60950 C-UL: CSA C22.2 No.60950 VDE: EN60950, IEC60950, VDE0805 Open board type: 73g/ enclosed type:160g 730’000 80 Conditions: *1 At cold start *2 At DC130V input/ rated output and 25°C *3 Measured by a bayonet probe at the end of a pair of 15cm long wires terminated with a 100µF electrolytic capacitor and 0.1µF film capacitor in parallel at a 0 to 100MHz bandwidth *4 Open board type: At –5 to +50°C/ enclosed type: at –5 to +40°C *5 For 7hour period after 1hour warm-up at 25°C and rated input/output *6 For less than 1minute of over current and short circuit *7 Safety approved at 25°C (contact technical sales) *8 Variable on input voltage and load conditions BWS-24SX-U Derating Efficiency ETA-POWER EUROPE LTD., Sennweidstr.45, 6312 Steinhausen, Switzerland Phone: +41 41 747 01 11, Fax: +41 41 747 01 22 E-Mail: sales@etapower.com, www.etapower.com OCP Block diagram ETA-POWER EUROPE LTD., Sennweidstr.45, 6312 Steinhausen, Switzerland Phone: +41 41 747 01 11, Fax: +41 41 747 01 22 E-Mail: sales@etapower.com, www.etapower.com Dimensions: ETA-POWER EUROPE LTD., Sennweidstr.45, 6312 Steinhausen, Switzerland Phone: +41 41 747 01 11, Fax: +41 41 747 01 22 E-Mail: sales@etapower.com, www.etapower.com