Signal Cable S-2Y2YBY 0.75 mm², 1.5 mm² and 2.5 mm²

S-2Y2YBY 0.75 mm², 1.5 mm² and 2.5 mm²
Signal Cable
Standard
6
5
4
3
2
ÖVE-K10/10
1
Construction
1
Solid copper conductor,
soft annealed
2
PE insulation
5
1 layer steel tape with a
thickness of 0.3 mm
6
PVC, UV resistant
3
Naturally coloured with a
blue marking core in each
layer
4
LLPE-sheath black
Application
Signal cable for the signal installations along the railway tracks. Can be laid in ground, cable ducts and tubes.
Properties
0.75 mm² 400 Veff
> 1.5 mm² 800 Veff
Rated voltage
Test voltage
0.75 mm² 2500 Veff, 50 Hz - 2 min
> 1.5 mm² 3500 Veff, 50 Hz - 2 min
Temperature range for handling
-20°C - +50°C
Max. storage temperature
40° C
Service temperature
-30°C - +60° C
Packaging Color of sheath
Wooden drums
Grey
RoHS
Comply with RoHS Directive
REACH
Comply with REACH Directive
Approved by ETS/ÖBB
All rights reserved. Any unauthorized usage, redistribution or reproduction of part or all of the content in any form will constitute an infringement of copyright. The data are only indicative and should
not be considered a binding representation or warranty from nkt cables concerning a product‘s properties or usability. The data page is not exhaustive and should be read in conjunction with nkt
cables other product data sheets, whether published or not. nkt cables reserves the right to change the data page without prior notice.
S-2Y2YBY 0.75 mm², 1.5 mm² and 2.5 mm²
Technical details
No. of cores
x cross section mm²
Cable diameter
nom.
Weight of
cable
Copper
weight
Conductor DC
resistance at 20 dg. C
Insulation
resistance
Mutual capacitance
at 800 Hz
mm2
mm
kg/km
kg/km
Ω/km
GΩxkm
nF/km
5x0,75
12.8
195
38
≤ 24.5
≥ 10
≤ 100
10x0,75
15.4
280
75
≤ 24.5
≥ 10
≤ 100
15x0,75
16.7
350
113
≤ 24.5
≥ 10
≤ 100
20x0,75
17.3
410
150
≤ 24.5
≥ 10
≤ 100
30x0,75
20.1
540
225
≤ 24.5
≥ 10
≤ 100
40x0,75
21.9
665
300
≤ 24.5
≥ 10
≤ 100
60x0,75
26.0
905
450
≤ 24.5
≥ 10
≤ 100
80x0,75
29.2
1175
600
≤ 24.5
≥ 10
≤ 100
100x0,75
32.4
1405
750
≤ 24.5
≥ 10
≤ 100
5x1,5
14.0
260
75
≤ 12.1
≥ 10
≤ 120
10x1,5
17.4
395
150
≤ 12.1
≥ 10
≤ 120
15x1,5
19.2
520
225
≤ 12.1
≥ 10
≤ 120
20x1,5
20.8
640
300
≤ 12.1
≥ 10
≤ 120
30x1,5
24.5
890
450
≤ 12.1
≥ 10
≤ 120
40x1,5
26.0
1105
600
≤ 12.1
≥ 10
≤ 120
60x1,5
31.6
1540
900
≤ 12.1
≥ 10
≤ 120
80x1,5
36.1
2000
1200
≤ 12.1
≥ 10
≤ 120
All rights reserved. Any unauthorized usage, redistribution or reproduction of part or all of the content in any form will constitute an infringement of copyright. The data are only indicative and should
not be considered a binding representation or warranty from nkt cables concerning a product‘s properties or usability. The data page is not exhaustive and should be read in conjunction with nkt
cables other product data sheets, whether published or not. nkt cables reserves the right to change the data page without prior notice.
S-2Y2YBY 0.75 mm², 1.5 mm² and 2.5 mm²
Technical details
No. of cores
x cross section mm²
Cable diameter
nom.
Weight of
cable
Copper
weight
Conductor DC
resistance at 20 dg. C
Insulation
resistance
Mutual capacitance
at 800 Hz
mm2
mm
kg/km
kg/km
Ω/km
GΩxkm
nF/km
100x1,5
40.2
2445
1500
≤ 12.1
≥ 10
≤ 120
5x2,5
15.6
330
125
≤ 7.28
≥ 10
≤ 120
10x2,5
19.7
525
250
≤ 7.28
≥ 10
≤ 120
15x2,5
22.0
710
375
≤ 7.28
≥ 10
≤ 120
20x2,5
24.7
915
500
≤ 7.28
≥ 10
≤ 120
30x2,5
28.6
1254
750
≤ 7.28
≥ 10
≤ 120
40x2,5
31.5‘
1590
1000
≤ 7.28
≥ 10
≤ 120
60x2,5
37.6
2275
1500
≤ 7.28
≥ 10
≤ 120
80x2,5
42.5
2930
2000
≤ 7.28
≥ 10
≤ 120
100x2,5
48.3
3625
2500
≤ 7.28
≥ 10
≤ 120
All rights reserved. Any unauthorized usage, redistribution or reproduction of part or all of the content in any form will constitute an infringement of copyright. The data are only indicative and should
not be considered a binding representation or warranty from nkt cables concerning a product‘s properties or usability. The data page is not exhaustive and should be read in conjunction with nkt
cables other product data sheets, whether published or not. nkt cables reserves the right to change the data page without prior notice.