UPR Series 16 and 32 Amp Plugs and Receptacles Catalog Pages

advertisement
ATX™ UPR Series 16 Amp Plugs and Sockets
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09
Applications
Features
• Plug and socket system is designed with a mechanical interlock
to insure disengagement cannot occur while energized.
• Large ON/OFF actuator on the receptacle gives clear, visible
indication of the receptacle status for maximum hazardous
location protection.
• Low Voltage receptacle can be locked in 0 (Off) and 1 (On)
positions.
• Different voltages are color coded for easy identification.
• The receptacles are keyed to accept UPR plugs of the proper
voltage.
• Receptacle explosionproof switch.
• UPR plugs can be used in non-hazardous IEC 60309-2 sockets.
• Operating temperature of -20 °C to +55 °C (-4 °F to +131 °F)
Wall Mounting Socket
Plugs and Receptacles: ATEX/IECEx Flameproof
• Plugs and receptacles are used with portable or stationery
electrical equipment such as:
— Lighting systems
— Conveyors
— Heaters
— Motor generators
— Air conditioning equipment
— Compressors
— Pumps
• For use in corrosive atmospheres and installations in Zone 1
and 2 and 21 and 22 of the oil and gas industry; such as:
­— Refineries
— Chemical and petrochemical plants
— Pipelines
— Loading docks
— Onshore and offshore drilling platforms
Plug
Technical Data
Breaking Capacity
AC1
AC3
AC15
DC1
16 Amp
690 Vac
8 Amp
500 Vac
4 Amp
690 Vac
16 Amp
690 Vac
16 Amp
415 Vac
10 Amp
24 Vdc
6 Amp
50 vdc
Short Circuit Withstand (ICC) : 10kA
Standard Materials
• Wall Socket: polyamide
• Plug: polyamide
ATEX/IECEx Certifications and Compliances
• Certification Type UPR
— Gas: Zones 1 and 2
– Conforming to ATEX 94/9/CE:
II 2 G
– Type of Protection: Ex db eb IIB
– Temperature Class: T6 for Ta ≤ +40 °C (+104 °F)
and T5 for +55 °C (+131 °F)
— Dust: Zones 21 and 22
– Conforming to ATEX 94/9/CE:
II 2 D
– Type of Protection: Ex tb IIIB
– Surface Temperature: T79 °C [Ta +40 °C (+104 °F)];
T94 °C [(Ta +55 °C (+131 °F)]
• Ambient Temperature: -20 °C ≤ Ta ≤ +55 °C (-4 °F ≤ Ta ≤ +131 °F)
• Index of Protection according EN/IEC 60529: IP66
• Impact Resistance (shock): IK09
• CE Declaration of Conformity: 50311
• ATEX Certificate: LCIE 15 ATEX 3054X
• IECEx Certificate: IECEx LCIE 15.0044X
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© September 2016
559
ATX™ UPR Series 16 Amp Plugs and Sockets
Increased Safety
Plugs and Receptacles: ATEX/IECEx Flameproof
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09
Wall Mounting Socket (LV)
• Two M25 threaded entries on the bottom. Available on top upon
request.
• Supplied with one M25 cable gland – Ø 8 to Ø 18.5 mm (0.31 to 0.73 in) and one M25 blanking plug.
• Terminal capacity 2 x 2.5 to 4 mm2 (#14 to #12 AWG). Can be through-wired up to 4 mm² (#12 AWG).
• Fitted with two linked earth terminals.
Plug (LV)
• Integrated cable clamp – Ø 9.2 to Ø 17 mm (0.36 to 0.67 in).
• Terminal capacity 2.5 to 4 mm2 (#14 to #12 AWG).
LV: Low Voltage
Yellow
100/130 Vac
560
Blue
200/250 Vac
Red
380/415 Vac
Black
480/500 Vac
600/690 Vac
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© September 2016
ATX™ UPR Series 16 Amp Plugs and Sockets
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09
Description
Low Voltage: LV
Weight kg (lb)
Volume dm3 (in3)
Color
Catalog Number
1.29 (2.84)
11.30 (689.57)
Yellow
UPR316RY4
0.31 (0.68)
2.40 (146.46)
Yellow
UPR316PY4
1.29 (2.84)
11.30 (689.57)
Blue
UPR316RB6
0.31 (0.68)
2.40 (146.46)
Blue
UPR316PB6
1.39 (3.06)
11.30 (689.57)
Blue
UPR416RB9
0.38 (0.84)
2.40 (146.46)
Blue
UPR416PB9
1.43 (3.15)
11.30 (689.57)
Blue
UPR516RB9
0.41 (0.90)
2.40 (146.46)
Blue
UPR516PB9
L2
1.39 (3.06)
11.30 (689.57)
Red
UPR416RR6
L3
0.38 (0.84)
2.40 (146.46)
Red
UPR416PR6
L3
1.43 (3.15)
11.30 (689.57)
Red
UPR516RR6
0.41 (0.90)
2.40 (146.46)
Red
UPR516PR6
1.39 (3.06)
11.30 (689.57)
Black
UPR416RN7
0.38 (0.84)
2.40 (146.46)
Black
UPR416PN7
1.43 (3.15)
11.30 (689.57)
Black
UPR516RN7
0.41 (0.90)
2.40 (146.46)
Black
UPR516PN7
Pin Configuration
100/130 Vac 50/60 Hz - Yellow
Wall Socket
4h
Plug
L/+
200/250 Vac 50/60 Hz - Blue
Wall Socket
L/+
6h
Plug
2P+E
L1
Wall Socket
L2
9h
L3
Plug
3P+E
L1
Wall Socket
L2
9h
N
Plug
L3
3P+N+E (1)
(1) 120/208 V - 144/250 Vac 50/60 Hz
380/415 Vac 50/60 Hz - Red
Wall Socket
L1
6h
Plug
3P+E
L2
Wall Socket
L1
Plug
6h
3P+N+E (2)
N
(2) 200/346 V - 240/415 Vac 50/60 Hz
480/500 Vac 50/60 Hz - Black
Wall Socket
7h
Plug
3P+E
Wall Socket
Plug
3P+N+E (3)
(3) 277/480-288/500 Vac 50/60Hz
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© September 2016
561
Plugs and Receptacles: ATEX/IECEx Flameproof
2P+E
ATX™ UPR Series 16 Amp Plugs and Sockets
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09
Description
Pin Configuration
Weight kg (lb)
Volume dm3 (in3)
Color
Catalog Number
1.39 (3.06)
11.30 (689.57)
Black
UPR416RN5
0.38 (0.84)
2.40 (146.46)
Black
UPR416PN5
1.43 (3.15)
11.30 (689.57)
Black
UPR516RN5
0.41 (0.90)
2.40 (146.46)
Black
UPR516PN5
Low Voltage: LV
600/690 Vac 50/60 Hz - Black
Wall Socket
Plug
Plugs and Receptacles: ATEX/IECEx Flameproof
3P+E
Wall Socket
Plug
3P+N+E
562
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© September 2016
ATX™ UPR Series 16 Amp Plugs and Sockets
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09
Dimensions in Millimeters (Inches)
16A — 2P+E — 3P+E —3P+N+E Versions
Wall Mounting Sockets
Plugs
Plugs and Receptacles: ATEX/IECEx Flameproof
132.6 (5.22)
Fix: 162.5 (6.40)
Fix: 115.0 (4.53)
6.0 (0.24)
Dimensions in Millimeters (Inches)
A
B
C
Dimensions in Millimeters (Inches)
D
B
C
2P+E
157.0 (6.18) 211.0 (8.31) 183.5 (7.22)
335.0 (13.19)
2P+E
81.0 (3.19)
183.0 (7.20)
44.0 (1.73)
3P+E
161.0 (6.34) 215.0 (8.47) 193.0 (7.60)
335.0 (13.19)
3P+E
89.0 (3.50)
183.0 (7.20)
49.0 (1.93)
3 P + N + E 163.0 (6.42) 215.0 (8.47) 193.0 (7.60)
335.0 (13.19)
3P+N+E
93.5 (3.68)
183.0 (7.20)
56.0 (2.20)
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© September 2016
A
563
ATX™ UPR Series 32 Amp Plugs and Sockets
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09
Plugs and Receptacles: ATEX/IECEx Flameproof
Applications
• Plugs and sockets are used with portable or stationery electrical equipment such as:
— Lighting systems
— Conveyors
— Heaters
— Motor generators
— Air conditioning equipment
— Compressors
— Pumps
• For use in corrosive atmospheres and installations in Zone 1
and 2 and 21 and 22 of the oil and gas industry, such as:
­— Refineries
— Chemical and petrochemical plants
— Pipelines
— Loading docks
— Onshore and offshore drilling platforms
Features
• Plug and socket system is designed with a mechanical interlock
to insure disengagement cannot occur while energized.
• Large ON/OFF actuator on the receptacle gives clear, visible
indication of the receptacle status for maximum hazardous
location protection.
• Low Voltage receptacle can be locked in 0 (Off) and 1 (On)
positions.
• Different voltages are color coded for easy identification.
• The receptacles are keyed to accept UPR plugs of the proper
voltage.
• Receptacle explosionproof switch.
• UPR plugs can be used in non-hazardous IEC 60309-2 sockets.
• Operating temperature of -20 °C to +55 °C (-4 °F to +131 °F)
Plug
Wall Mounting Socket
Technical Data
Breaking Capacity
AC3
32 Amp
690 Vac
AC22
32 Amp
690 Vac
Short Circuit Withstand (ICC) : 10kA
Standard Materials
• Wall Socket: polyamide
• Plug: polyamide
ATEX/IECEx Certifications and Compliances
• Certification Type UPR
— Gas: Zones 1 and 2
– Conforming to ATEX 94/9/CE:
II 2 G
– Type of Protection: Ex db eb IIB
– Temperature Class: T6 for Ta ≤ +40 °C (+104 °F)
and T5 for +55 °C (+131 °F)
— Dust: Zones 21 and 22
– Conforming to ATEX 94/9/CE:
II 2 D
– Type of Protection: Ex tb IIIB
– Surface Temperature: T79 °C [Ta +40 °C (+104 °F)];
T94 °C [(Ta +55 °C (+131 °F)]
• Ambient Temperature: -20 °C ≤ Ta ≤ +55 °C (-4 °F ≤ Ta ≤ +131 °F)
• Index of Protection according EN/IEC 60529: IP66
• Impact Resistance (shock): IK09
• CE Declaration of Conformity: 50311
• ATEX Certificate: LCIE 15 ATEX 3054X
• IECEx Certificate: IECEx LCIE 15.0044X
564
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© September 2016
ATX™ UPR Series 32 Amp Plugs and Sockets
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09
Plugs and Receptacles: ATEX/IECEx Flameproof
Wall Mounting Socket
Plug
• Two M32 threaded entries on the bottom or top upon request.
• Supplied with one M32 cable gland – Ø 10 to Ø 25 mm (0.39 to 0.98 in) and one M32 blanking plugs.
• Terminal capacity 2 x 6 to 10 mm² (#10 to #8 AWG). Can be through-wired up to 6mm² (#10 AWG).
• Fitted with two linked earth terminals.
• One integrated cable clamp – Ø 14.1 to Ø 29.1 mm (0.55 to 0.98 in) for 3P+N+E versions.
• Terminal capacity 6 to 10 mm (#10 to #8 AWG).
2 LV - Low Voltage
Yellow
Blue
Red
Black
100/130 Vac
200/250 Vac
380/415 Vac
480/500 Vac
600/690 Vac
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© September 2016
565
ATX™ UPR Series 32 Amp Plugs and Sockets
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09
Description
Pin Configuration
Volume dm3 (in3)
Color
Catalog Number
11.30 (689.57)
Yellow
UPR332RY4
2.40 (146.46)
Yellow
UPR332PY4
11.30 (689.57)
Blue
UPR332RB6
0.46 (1.01)
2.40 (146.46)
Blue
UPR332PB6
1.85 (4.08)
11.30 (689.57)
Blue
UPR432RB9
0.49 (1.08)
2.40 (146.46)
Blue
UPR432PB9
1.91 (4.21)
11.30 (689.57)
Blue
UPR532RB9
0.54 (1.19)
2.40 (146.46)
Blue
UPR532PB9
1.85 (4.08)
11.30 (689.57)
Red
UPR432RR6
0.49 (1.08)
2.40 (146.46)
Red
UPR432PR6
1.91 (4.21)
11.30 (689.57)
Red
UPR532RR6
0.54 (1.19)
2.40 (146.46)
Red
UPR532PR6
Weight kg (lb)
100/130 Vac 50/60 Hz - Yellow
Wall Socket
L/+
Plug
Plugs and Receptacles: ATEX/IECEx Flameproof
1.71 (3.77)
4h
0.46 (1.01)
2P+E
200/250 Vac 50/60 Hz - Blue
1.71 (3.77)
L/+
Wall Socket
6h
Plug
2P+E
L1
Wall Socket
9h
L3
Plug
L2
9h
N
Plug
3P+E
L1
Wall Socket
L2
L3
3P+N+E (1)
(1) 120/208 V - 144/250 Vac 50/60 Hz
380/415 Vac 50/60 Hz - Red
L2
Wall Socket
L1
6h
Plug
3P+E
L3
L2
Wall Socket
L1
Plug
L3
6h
N
3P+N+E (2)
(2) 200/346 V - 240/415 Vac 50/60 Hz
480/500 Vac 50/60 Hz - Black
Wall Socket
7h
1.85 (4.08)
11.30 (689.57)
Black
UPR432RN7
Plug
3P+E
0.49 (1.08)
2.40 (146.46)
Black
UPR432PN7
1.91 (4.21)
11.30 (689.57)
Black
UPR532RN7
0.54 (1.19)
2.40 (146.46)
Black
UPR532PN7
1.85 (4.08)
11.30 (689.57)
Black
UPR432RN5
0.49 (1.08)
2.40 (146.46)
Black
UPR432PN5
Wall Socket
Plug
3P+N+E
600/690 Vac 50/60 Hz -Black
Wall Socket
Plug
566
3P+E
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© September 2016
ATX™ UPR Series 32 Amp Plugs and Sockets
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09
Dimensions in Millimeters (Inches)
32A — 2P+E — 3P+E —3P+N+E Versions
Wall Mounting Sockets
Plugs
Plugs and Receptacles: ATEX/IECEx Flameproof
150.0 (5.91)
Fix 194.0 (7.64)
131.0 (5.16)
6.0 (0.24)
A
Dimensions in Millimeters (Inches)
B
C
D
A
Dimensions in Millimeters (Inches)
B
C
2P+E
175.0 (6.89) 250.0 (9.84) 210.0 (8.27)
380.0 (14.96)
2P+E
98.0 (3.86)
200.0 (7.87)
57.0 (2.24)
3P+E
175.0 (6.89) 250.0 (9.84) 210.0 (8.27)
380.0 (14.96)
3P+E
98.0 (3.86)
200.0 (7.87)
57.0 (2.24)
3 P + N + E 177.0 (6.97) 250.0 (9.84) 210.0 (8.27)
380.0 (14.96)
3P+N+E
102.0 (4.02)
200.0 (7.87)
63.0 (2.48)
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© September 2016
567
Download