ATX™ UPR Series 16 Amp Plugs and Sockets Increased Safety ATEX/IECEx: Zone 1 and 2 - 21 and 22 II 2 GD IP66 - IK09 Applications Features • Plug and socket system is designed with a mechanical interlock to insure disengagement cannot occur while energized. • Large ON/OFF actuator on the receptacle gives clear, visible indication of the receptacle status for maximum hazardous location protection. • Low Voltage receptacle can be locked in 0 (Off) and 1 (On) positions. • Different voltages are color coded for easy identification. • The receptacles are keyed to accept UPR plugs of the proper voltage. • Receptacle explosionproof switch. • UPR plugs can be used in non-hazardous IEC 60309-2 sockets. • Operating temperature of -20 °C to +55 °C (-4 °F to +131 °F) Wall Mounting Socket Plugs and Receptacles: ATEX/IECEx Flameproof • Plugs and receptacles are used with portable or stationery electrical equipment such as: — Lighting systems — Conveyors — Heaters — Motor generators — Air conditioning equipment — Compressors — Pumps • For use in corrosive atmospheres and installations in Zone 1 and 2 and 21 and 22 of the oil and gas industry; such as: ­— Refineries — Chemical and petrochemical plants — Pipelines — Loading docks — Onshore and offshore drilling platforms Plug Technical Data Breaking Capacity AC1 AC3 AC15 DC1 16 Amp 690 Vac 8 Amp 500 Vac 4 Amp 690 Vac 16 Amp 690 Vac 16 Amp 415 Vac 10 Amp 24 Vdc 6 Amp 50 vdc Short Circuit Withstand (ICC) : 10kA Standard Materials • Wall Socket: polyamide • Plug: polyamide ATEX/IECEx Certifications and Compliances • Certification Type UPR — Gas: Zones 1 and 2 – Conforming to ATEX 94/9/CE: II 2 G – Type of Protection: Ex db eb IIB – Temperature Class: T6 for Ta ≤ +40 °C (+104 °F) and T5 for +55 °C (+131 °F) — Dust: Zones 21 and 22 – Conforming to ATEX 94/9/CE: II 2 D – Type of Protection: Ex tb IIIB – Surface Temperature: T79 °C [Ta +40 °C (+104 °F)]; T94 °C [(Ta +55 °C (+131 °F)] • Ambient Temperature: -20 °C ≤ Ta ≤ +55 °C (-4 °F ≤ Ta ≤ +131 °F) • Index of Protection according EN/IEC 60529: IP66 • Impact Resistance (shock): IK09 • CE Declaration of Conformity: 50311 • ATEX Certificate: LCIE 15 ATEX 3054X • IECEx Certificate: IECEx LCIE 15.0044X Visit our website at www.emerson.com or contact us at (800) 621-1506. © September 2016 559 ATX™ UPR Series 16 Amp Plugs and Sockets Increased Safety Plugs and Receptacles: ATEX/IECEx Flameproof ATEX/IECEx: Zone 1 and 2 - 21 and 22 II 2 GD IP66 - IK09 Wall Mounting Socket (LV) • Two M25 threaded entries on the bottom. Available on top upon request. • Supplied with one M25 cable gland – Ø 8 to Ø 18.5 mm (0.31 to 0.73 in) and one M25 blanking plug. • Terminal capacity 2 x 2.5 to 4 mm2 (#14 to #12 AWG). Can be through-wired up to 4 mm² (#12 AWG). • Fitted with two linked earth terminals. Plug (LV) • Integrated cable clamp – Ø 9.2 to Ø 17 mm (0.36 to 0.67 in). • Terminal capacity 2.5 to 4 mm2 (#14 to #12 AWG). LV: Low Voltage Yellow 100/130 Vac 560 Blue 200/250 Vac Red 380/415 Vac Black 480/500 Vac 600/690 Vac Visit our website at www.emerson.com or contact us at (800) 621-1506. © September 2016 ATX™ UPR Series 16 Amp Plugs and Sockets Increased Safety ATEX/IECEx: Zone 1 and 2 - 21 and 22 II 2 GD IP66 - IK09 Description Low Voltage: LV Weight kg (lb) Volume dm3 (in3) Color Catalog Number 1.29 (2.84) 11.30 (689.57) Yellow UPR316RY4 0.31 (0.68) 2.40 (146.46) Yellow UPR316PY4 1.29 (2.84) 11.30 (689.57) Blue UPR316RB6 0.31 (0.68) 2.40 (146.46) Blue UPR316PB6 1.39 (3.06) 11.30 (689.57) Blue UPR416RB9 0.38 (0.84) 2.40 (146.46) Blue UPR416PB9 1.43 (3.15) 11.30 (689.57) Blue UPR516RB9 0.41 (0.90) 2.40 (146.46) Blue UPR516PB9 L2 1.39 (3.06) 11.30 (689.57) Red UPR416RR6 L3 0.38 (0.84) 2.40 (146.46) Red UPR416PR6 L3 1.43 (3.15) 11.30 (689.57) Red UPR516RR6 0.41 (0.90) 2.40 (146.46) Red UPR516PR6 1.39 (3.06) 11.30 (689.57) Black UPR416RN7 0.38 (0.84) 2.40 (146.46) Black UPR416PN7 1.43 (3.15) 11.30 (689.57) Black UPR516RN7 0.41 (0.90) 2.40 (146.46) Black UPR516PN7 Pin Configuration 100/130 Vac 50/60 Hz - Yellow Wall Socket 4h Plug L/+ 200/250 Vac 50/60 Hz - Blue Wall Socket L/+ 6h Plug 2P+E L1 Wall Socket L2 9h L3 Plug 3P+E L1 Wall Socket L2 9h N Plug L3 3P+N+E (1) (1) 120/208 V - 144/250 Vac 50/60 Hz 380/415 Vac 50/60 Hz - Red Wall Socket L1 6h Plug 3P+E L2 Wall Socket L1 Plug 6h 3P+N+E (2) N (2) 200/346 V - 240/415 Vac 50/60 Hz 480/500 Vac 50/60 Hz - Black Wall Socket 7h Plug 3P+E Wall Socket Plug 3P+N+E (3) (3) 277/480-288/500 Vac 50/60Hz Visit our website at www.emerson.com or contact us at (800) 621-1506. © September 2016 561 Plugs and Receptacles: ATEX/IECEx Flameproof 2P+E ATX™ UPR Series 16 Amp Plugs and Sockets Increased Safety ATEX/IECEx: Zone 1 and 2 - 21 and 22 II 2 GD IP66 - IK09 Description Pin Configuration Weight kg (lb) Volume dm3 (in3) Color Catalog Number 1.39 (3.06) 11.30 (689.57) Black UPR416RN5 0.38 (0.84) 2.40 (146.46) Black UPR416PN5 1.43 (3.15) 11.30 (689.57) Black UPR516RN5 0.41 (0.90) 2.40 (146.46) Black UPR516PN5 Low Voltage: LV 600/690 Vac 50/60 Hz - Black Wall Socket Plug Plugs and Receptacles: ATEX/IECEx Flameproof 3P+E Wall Socket Plug 3P+N+E 562 Visit our website at www.emerson.com or contact us at (800) 621-1506. © September 2016 ATX™ UPR Series 16 Amp Plugs and Sockets Increased Safety ATEX/IECEx: Zone 1 and 2 - 21 and 22 II 2 GD IP66 - IK09 Dimensions in Millimeters (Inches) 16A — 2P+E — 3P+E —3P+N+E Versions Wall Mounting Sockets Plugs Plugs and Receptacles: ATEX/IECEx Flameproof 132.6 (5.22) Fix: 162.5 (6.40) Fix: 115.0 (4.53) 6.0 (0.24) Dimensions in Millimeters (Inches) A B C Dimensions in Millimeters (Inches) D B C 2P+E 157.0 (6.18) 211.0 (8.31) 183.5 (7.22) 335.0 (13.19) 2P+E 81.0 (3.19) 183.0 (7.20) 44.0 (1.73) 3P+E 161.0 (6.34) 215.0 (8.47) 193.0 (7.60) 335.0 (13.19) 3P+E 89.0 (3.50) 183.0 (7.20) 49.0 (1.93) 3 P + N + E 163.0 (6.42) 215.0 (8.47) 193.0 (7.60) 335.0 (13.19) 3P+N+E 93.5 (3.68) 183.0 (7.20) 56.0 (2.20) Visit our website at www.emerson.com or contact us at (800) 621-1506. © September 2016 A 563 ATX™ UPR Series 32 Amp Plugs and Sockets Increased Safety ATEX/IECEx: Zone 1 and 2 - 21 and 22 II 2 GD IP66 - IK09 Plugs and Receptacles: ATEX/IECEx Flameproof Applications • Plugs and sockets are used with portable or stationery electrical equipment such as: — Lighting systems — Conveyors — Heaters — Motor generators — Air conditioning equipment — Compressors — Pumps • For use in corrosive atmospheres and installations in Zone 1 and 2 and 21 and 22 of the oil and gas industry, such as: ­— Refineries — Chemical and petrochemical plants — Pipelines — Loading docks — Onshore and offshore drilling platforms Features • Plug and socket system is designed with a mechanical interlock to insure disengagement cannot occur while energized. • Large ON/OFF actuator on the receptacle gives clear, visible indication of the receptacle status for maximum hazardous location protection. • Low Voltage receptacle can be locked in 0 (Off) and 1 (On) positions. • Different voltages are color coded for easy identification. • The receptacles are keyed to accept UPR plugs of the proper voltage. • Receptacle explosionproof switch. • UPR plugs can be used in non-hazardous IEC 60309-2 sockets. • Operating temperature of -20 °C to +55 °C (-4 °F to +131 °F) Plug Wall Mounting Socket Technical Data Breaking Capacity AC3 32 Amp 690 Vac AC22 32 Amp 690 Vac Short Circuit Withstand (ICC) : 10kA Standard Materials • Wall Socket: polyamide • Plug: polyamide ATEX/IECEx Certifications and Compliances • Certification Type UPR — Gas: Zones 1 and 2 – Conforming to ATEX 94/9/CE: II 2 G – Type of Protection: Ex db eb IIB – Temperature Class: T6 for Ta ≤ +40 °C (+104 °F) and T5 for +55 °C (+131 °F) — Dust: Zones 21 and 22 – Conforming to ATEX 94/9/CE: II 2 D – Type of Protection: Ex tb IIIB – Surface Temperature: T79 °C [Ta +40 °C (+104 °F)]; T94 °C [(Ta +55 °C (+131 °F)] • Ambient Temperature: -20 °C ≤ Ta ≤ +55 °C (-4 °F ≤ Ta ≤ +131 °F) • Index of Protection according EN/IEC 60529: IP66 • Impact Resistance (shock): IK09 • CE Declaration of Conformity: 50311 • ATEX Certificate: LCIE 15 ATEX 3054X • IECEx Certificate: IECEx LCIE 15.0044X 564 Visit our website at www.emerson.com or contact us at (800) 621-1506. © September 2016 ATX™ UPR Series 32 Amp Plugs and Sockets Increased Safety ATEX/IECEx: Zone 1 and 2 - 21 and 22 II 2 GD IP66 - IK09 Plugs and Receptacles: ATEX/IECEx Flameproof Wall Mounting Socket Plug • Two M32 threaded entries on the bottom or top upon request. • Supplied with one M32 cable gland – Ø 10 to Ø 25 mm (0.39 to 0.98 in) and one M32 blanking plugs. • Terminal capacity 2 x 6 to 10 mm² (#10 to #8 AWG). Can be through-wired up to 6mm² (#10 AWG). • Fitted with two linked earth terminals. • One integrated cable clamp – Ø 14.1 to Ø 29.1 mm (0.55 to 0.98 in) for 3P+N+E versions. • Terminal capacity 6 to 10 mm (#10 to #8 AWG). 2 LV - Low Voltage Yellow Blue Red Black 100/130 Vac 200/250 Vac 380/415 Vac 480/500 Vac 600/690 Vac Visit our website at www.emerson.com or contact us at (800) 621-1506. © September 2016 565 ATX™ UPR Series 32 Amp Plugs and Sockets Increased Safety ATEX/IECEx: Zone 1 and 2 - 21 and 22 II 2 GD IP66 - IK09 Description Pin Configuration Volume dm3 (in3) Color Catalog Number 11.30 (689.57) Yellow UPR332RY4 2.40 (146.46) Yellow UPR332PY4 11.30 (689.57) Blue UPR332RB6 0.46 (1.01) 2.40 (146.46) Blue UPR332PB6 1.85 (4.08) 11.30 (689.57) Blue UPR432RB9 0.49 (1.08) 2.40 (146.46) Blue UPR432PB9 1.91 (4.21) 11.30 (689.57) Blue UPR532RB9 0.54 (1.19) 2.40 (146.46) Blue UPR532PB9 1.85 (4.08) 11.30 (689.57) Red UPR432RR6 0.49 (1.08) 2.40 (146.46) Red UPR432PR6 1.91 (4.21) 11.30 (689.57) Red UPR532RR6 0.54 (1.19) 2.40 (146.46) Red UPR532PR6 Weight kg (lb) 100/130 Vac 50/60 Hz - Yellow Wall Socket L/+ Plug Plugs and Receptacles: ATEX/IECEx Flameproof 1.71 (3.77) 4h 0.46 (1.01) 2P+E 200/250 Vac 50/60 Hz - Blue 1.71 (3.77) L/+ Wall Socket 6h Plug 2P+E L1 Wall Socket 9h L3 Plug L2 9h N Plug 3P+E L1 Wall Socket L2 L3 3P+N+E (1) (1) 120/208 V - 144/250 Vac 50/60 Hz 380/415 Vac 50/60 Hz - Red L2 Wall Socket L1 6h Plug 3P+E L3 L2 Wall Socket L1 Plug L3 6h N 3P+N+E (2) (2) 200/346 V - 240/415 Vac 50/60 Hz 480/500 Vac 50/60 Hz - Black Wall Socket 7h 1.85 (4.08) 11.30 (689.57) Black UPR432RN7 Plug 3P+E 0.49 (1.08) 2.40 (146.46) Black UPR432PN7 1.91 (4.21) 11.30 (689.57) Black UPR532RN7 0.54 (1.19) 2.40 (146.46) Black UPR532PN7 1.85 (4.08) 11.30 (689.57) Black UPR432RN5 0.49 (1.08) 2.40 (146.46) Black UPR432PN5 Wall Socket Plug 3P+N+E 600/690 Vac 50/60 Hz -Black Wall Socket Plug 566 3P+E Visit our website at www.emerson.com or contact us at (800) 621-1506. © September 2016 ATX™ UPR Series 32 Amp Plugs and Sockets Increased Safety ATEX/IECEx: Zone 1 and 2 - 21 and 22 II 2 GD IP66 - IK09 Dimensions in Millimeters (Inches) 32A — 2P+E — 3P+E —3P+N+E Versions Wall Mounting Sockets Plugs Plugs and Receptacles: ATEX/IECEx Flameproof 150.0 (5.91) Fix 194.0 (7.64) 131.0 (5.16) 6.0 (0.24) A Dimensions in Millimeters (Inches) B C D A Dimensions in Millimeters (Inches) B C 2P+E 175.0 (6.89) 250.0 (9.84) 210.0 (8.27) 380.0 (14.96) 2P+E 98.0 (3.86) 200.0 (7.87) 57.0 (2.24) 3P+E 175.0 (6.89) 250.0 (9.84) 210.0 (8.27) 380.0 (14.96) 3P+E 98.0 (3.86) 200.0 (7.87) 57.0 (2.24) 3 P + N + E 177.0 (6.97) 250.0 (9.84) 210.0 (8.27) 380.0 (14.96) 3P+N+E 102.0 (4.02) 200.0 (7.87) 63.0 (2.48) Visit our website at www.emerson.com or contact us at (800) 621-1506. © September 2016 567