GM Series Direct Coupled Actuator Minimum 360 in-lb Torque For damper areas up to 90 sq-ft* Wiring Auxiliary Switch Variable (0 to 10 VDC) 150 seconds Adj. 75 to 280 seconds Plenum Rated Cable Appliance Rated Cable Conduit Fitting Add-On ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Installation and Operations…(page 269). *Based on 4 in-lb/ft2 damper torque loading. Parallel blade. No edge seals. 800-543-9038 USA 187 207) GMX24- ● ● ● ® None 2 to 10 VDC LON (p. 05) PC (p. 2 GMX24- MFT95 (p. 203) 4 (p. 201 MFT-T N . 199) GMB(X)2 4-MFT (p GMB24- SR-T N4 . 195) 4-SR (p 3) -3 (p. 19 GMX120 3-T N4 ● ● 866-805-7089 CANADA 203-791-8396 LATIN AMERICA M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. Running Time ● GMX24- 360 in-lb [40 Nm] 95 degrees 24 VAC/DC 100 to 240 VAC On/Off, Floating Point 2 to 10 VDC (4 to 20mA) Multi-Function Technology 0 to 135 Ohm 0 to 20V Phasecut ● ● ● LonWORKS Feedback ● GMX24- Control Input ● GMB(X)2 Basic Product Flexible Product Torque Angle of Rotation Power Supply GMB24- GM Series - At A Glance GMB(X)2 4-3 (p. 1 89) (p. 191) Actuators in bold have BDCM (p. 197) ) ● GM Series Direct Coupled Actuator M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. A CLOSER LOOK… ● Brushless DC Motor for Added Accuracy and Controllability. ● Cut Labor Costs with Simple Direct Coupling. ● Self-Centers on 1.05" or 3/4” with the Standard Clamp. ● Check Damper Position with Clear Position Indicator. ● Don’t Worry about Actuator Burn-Out; Belimo is Overload Proof throughout Rotation. ● Enjoy Added Flexibility with Easy Mechanical Stops to Adjust Angle of Rotation. ● Need to Change Control Direction? Do it easily with a Simple Switch. ● Easily Accessible Manual Override Button helps you Pre-Tension Damper Blades. ● Auxiliary Switch and Feedback Potentiometer Add-Ons Mount Directly on Clamp, Includes Conduit Connector. ● Standard 3ft Plenum Rated Cable and Conduit Connector Provided on Basic Models. ● Added Flexibility to Select Clamp, Electrical Connection, and Running Time to fit your Specific Application with Belimo’s New Flexible Line of Actuators. The Belimo Difference ● Customer Commitment. Extensive product range. Application assistance. Same-day shipments. Free technical support. Five year warranty. ● Low Installation and Life-Cycle Cost. Easy installation. Accuracy and repeatability. Low power consumption. No maintenance. ● Long Service Life. Components tested before assembly. Every product tested before shipment. 30+ years direct coupled actuator design. 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 188 GMB(X)24-3 On/Off, Floating Point, Non-Spring Return, 24 V Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft. Application For on/off and floating point control of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer’s specifications. The actuator is mounted directly to a damper shaft up to 1.05” in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. Operation The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. The GMB(X) series provides 95° of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. Overload protection Control Input impedance Angle of rotation Torque Direction of rotation Position indication Manual override Running time Humidity Ambient temperature Storage temperature Housing Housing material Agency listings† Noise level Servicing Quality standard Weight Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. Dimensions (Inches [mm]) 1/2” to 1.05” [12.7 to 26.67] 2/5” to 1.05” [10 to 26.67] 5.37” [136.4] To center of mounting slot. 7.02” [178.4] 1.42” [36] 5.6” [142.4] 2” [50.8] †Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3. 800-543-9038 USA 189 866-805-7089 CANADA 203-791-8396 LATIN AMERICA M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. Power consumption Transformer sizing Electrical connection D123 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% 4 W (2 W) 6 VA (Class 2 power source) 18 GA plenum rated cable 1/2” conduit connector protected NEMA 2 (IP54) 3 ft [1m] 10 ft [3m] 16 ft [5m] electronic throughout 0 to 95° rotation on/off, floating point 600 Ω max. 95°, adjustable with mechanical stop 360 in-lb [40 Nm] reversible with switch reflective visual indicator (snap-on) external push button 150 seconds, constant independent of load 5 to 95% RH non condensing (EN 60730-1) -22°F to +122°F [-30°C to +50°C] -40°F to +176°F [-40°C to +80°C] NEMA 2, IP54, UL enclosure type 2 UL94-5VA cULus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EEC and 2006/95/EC <45dB(A) maintenance free ISO 9001 3.4 lbs [1.55 kg] 2.9” [72.9] GMB(X)24-3 Power supply 4.55” [115.6] Technical Data The GMB(X)24-3... actuators use a brushless DC motor, which is controlled by an Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. GMB(X)24-3 On/Off, Floating Point, Non-Spring Return, 24 V Accessories K-GM20 ZG-102 Z-GMA ZG-GMA ZG-JSA (-1, 2, 3) ZS-100 ZS-150 ZS-260 ZS-300 (-1) (-5) Tool-07 S1A, S2A P370 P…A Wiring Diagrams 1/2”-1.05 [12.7 to 26.67 mm] Shaft Clamp Multiple Actuator Mounting Bracket GM to GM Retrofit Mounting Bracket Crank arm Adaptor Kit Jackshaft Adaptors for Hollow Jackshafts Weather Shield - Steel Weather Shield - Polycarbonate Explosion Proof Housing NEMA 4X Housing 13 mm Wrench Auxiliary Switch (es) Shaft Mount Auxiliary Switch Feedback Potentiometers 1 Provide overload protection and disconnect as required. 3 Actuators may also be powered by 24 VDC. Meets cULus requirements without the need of an electrical ground connection. WARNING G Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. NOTE: When using GMB(X)24-3... actuators, only use accessories listed on this page. Typical Specification W254_08 Floating point, on/off control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05” diameter. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. Actuators shall be cULus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. W255_08 On/Off control Floating Point or On/Off control 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 190 GMB24-3-T N4 NEMA 4 , On/Off, Floating Point Control, Non-Spring Return, Direct Coupled, 24 VAC Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft. Application For on/off and floating point control of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer’s specifications. The actuator is mounted directly to a damper shaft up to 1.05" in diameter by means of its universal clamp. Operation The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. The GMB24-3-T N4 provides 95° of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator after the cover is removed. Overload protection Control Input impedance Angle of rotation Torque Direction of rotation Position indication Running time Humidity Ambient temperature Storage temperature Housing Housing material Agency listings† Noise level Servicing Quality standard Weight reversible with switch dial 150 seconds constant independent of load 5 to 100% RH (UL Type 4) -22°F to 122°F [-30°C to 50°C] -40°F to 176°F [-40°C to 80°C] UL Type 4, NEMA 4, IP66 polycarbonate cULus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1, CSA C22.2 No. 24-93, CE acc. to 89/336/EEC <45dB(A) maintenance free ISO 9001 4.8 lbs [4.45 kg] Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. Dimensions (mm [inches]) 172 [6.77] †Rated Impulse Voltage 4kV, Type of action 1, Control Pollution Degree 3. 800-543-9038 USA 191 866-805-7089 CANADA 203-791-8396 LATIN AMERICA M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. Power consumption Transformer sizing Electrical connection GMB24-3-T N4 24 VAC ±20%, 50/60 Hz 24 VDC ±10%, 50/60 Hz 4.0 W (2.0 W) 6 VA (Class 2 power source) screw terminal (for 26 to 14 GA wire) ½” conduit connector electronic throughout 0 to 95° rotation on/off, floating point 600 Ω max. 95°, adjustable with mechanical stop 360 in-lb [40 Nm] D312 Technical Data Power supply The GMB24-3-T N4 actuator uses a sensorless brushless DC motor, which is controlled by an Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. GMB24-3-T N4 NEMA 4 , On/Off, Floating Point Control, Non-Spring Return, Direct Coupled, 24 VAC Wiring Diagrams Accessories S1A, S2A P…A 43442-00001 11097-00001 Auxiliary Switch (es) Feedback Potentiometers Gland* Gasket for Gland* 1 Provide overload protection and disconnect as required. NOTE: When using GMB24-3-T N4 actuators, only use accessories listed on this page. * Both parts are needed when using an auxiliary switch or potentiometer with GMB24-3-T N4 Meets cULus or UL and CSA requirements without the need of an electrical ground connection. Typical Specification WARNING G Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. On/Off, Floating Point control damper actuators shall be electronic directcoupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05” diameter. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover of the actuator. Run time shall be constant and independent of torque. Actuators shall be cULus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. AMB24-3-T N4 M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. On/Off control AMB24-3-T N4 Floating Point or On/Off control 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 192 GMX120-3 On/Off, Floating Point, Non-Spring Return, 100 to 240 VAC Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft. Application For on/off and floating point control of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer’s specifications. The actuator is mounted directly to a damper shaft up to 1.05” in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. Operation The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. The GMX series provides 95° of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. Overload protection Control Input impedance Angle of rotation Torque Direction of rotation Position indication Manual override Running time Humidity Ambient temperature Storage temperature Housing Housing material Agency listings† Noise level Servicing Quality standard Weight Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. Dimensions (Inches [mm]) 1/2” to 1.05” [12.7 to 26.67] 2/5” to 1.05” [10 to 26.67] 5.37” [136.4] To center of mounting slot. 7.02” [178.4] 1.42” [36] 5.6” [142.4] 2” [50.8] †Rated Impulse Voltage 2.5kV, Type of action 1, Control Pollution Degree 3. 800-543-9038 USA 193 866-805-7089 CANADA 203-791-8396 LATIN AMERICA M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. Power consumption Transformer sizing Electrical connection D123 100 to 240 VAC, 50/60 Hz (nominal) 85 to 265 VAC, 50/60 Hz (tolerance) 4 W (2 W) 7 VA (Class 2 power source) 18 GA appliance rated cable 1/2” conduit connector protected NEMA 2 (IP54) 3 ft [1m] 10 ft [3m] 16 ft [5m] electronic throughout 0 to 95° rotation on/off, floating point 600 Ω max. 95°, adjustable with mechanical stop 360 in-lb [40 Nm] reversible with switch reflective visual indicator (snap-on) external push button 150 seconds, constant independent of load 5 to 95% RH non condensing (EN 60730-1) -22°F to 122°F [-30°C to 50°C] -40°F to 176°F [-40°C to 80°C] NEMA 2, IP54, UL enclosure type 2 UL94-5VA cULus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EEC and 2006/95/EC <45dB(A) maintenance free ISO 9001 3.4 lbs [1.55 kg] 2.9” [72.9] GMX120-3 Power supply 4.55” [115.6] Technical Data The GMX120-3 actuators use a sensorless brushless DC motor, which is controlled by an Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. GMX120-3 On/Off, Floating Point, Non-Spring Return, 100 to 240 VAC Accessories Wiring Diagrams 1/2”-1.05 [12.7 to 26.67 mm] Shaft Clamp Multiple Actuator Mounting Bracket GM to GM Retrofit Mounting Bracket Crank arm Adaptor Kit Jackshaft Adaptors for Hollow Jackshafts Weather Shield - Steel Weather Shield - Polycarbonate Explosion Proof Housing NEMA 4X Housing 13 mm Wrench Auxiliary Switch (es) Shaft Mount Auxiliary Switch Feedback Potentiometers 1 Provide overload protection and disconnect as required. 2 CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. Meets cULus requirements without the need of an electrical ground connection. WARNING G Live Electrical Components! NOTE: When using GMX120-3 actuators, only use accessories listed on this page. Typical Specification Floating point, on/off control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05” diameter. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. Actuators shall be cULus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. W375_08 K-GM20 ZG-102 Z-GMA ZG-GMA ZG-JSA (-1, 2, 3) ZS-100 ZS-150 ZS-260 ZS-300 (-1) (-5) Tool-07 S1A, S2A P370 P…A M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. W376_08 On/Off control Floating Point or On/Off control 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 194 GMB(X)24-SR Proportional, Non-Spring Return, 24 V, for 2 to 10 VDC or 4 to 20 mA T Torque min. i 360 in-lb i lb for f controll off damper d surfaces f up to 90 sq ft. f Application For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer’s specifications. The actuator is mounted directly to a damper shaft up to 1.05” in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. The actuator operates in response to a 2 to 10 VDC, or with the addition of a 500 Ω resistor, a 4 to 20 mA control input from an electronic controller or positioner. A 2 to 10 VDC feedback signal is provided for position indication or master-slave applications. Operation The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. Overload protection Operating range Y Input impedance Feedback Output U Angle of Rotation Torque Direction of Rotation Position indication Manual override Running time Humidity Ambient temperature Storage temperature Housing Housing material Agency listings† Noise level Servicing Quality standard Weight The GMB(X)24-SR… actuators use a sensorless brushless DC motor, which is controlled by an Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. Dimensions (Inches [mm]) 1/2” to 1.05” [12.7 to 26.67] 2/5” to 1.05” [10 to 26.67] 5.37” [136.4] To center of mounting slot. 7.02” [178.4] 1.42” [36] 5.6” [142.4] 2” [50.8] †Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3. 800-543-9038 USA 195 866-805-7089 CANADA 203-791-8396 LATIN AMERICA M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. Power consumption Transformer sizing Electrical connection D123 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% 4.5 W (2W) 6.5 VA (Class 2 power source) 18 GA plenum rated cable 1/2” conduit connector protected NEMA 2 (IP54) 3 ft [1m] 10 ft [3m] 16 ft [5m] electronic throughout 0 to 95° rotation 2 to 10 VDC, 4 to 20 mA 100 kΩ (0.1 mA), 500Ω 2 to 10 VDC (max 0.5 mA) max. 95°, adjustable with mechanical stop 360 in-lb [40 Nm] reversible with switch actuator will move: =CCW with decreasing control signal (10 to 2V) =CW with decreasing control signal (10 to 2V) reflective visual indicator (snap-on) external push button 150 seconds, constant independent of load 5 to 95% RH non condensing (EN 60730-1) -22°F to 122°F [-30°C to 50°C] -40°F to 176°F [-40°C to 80°C] NEMA 2, IP54, UL enclosure type 2 UL94-5VA cULus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EEC and 2006/95/EC <45dB(A) maintenance free ISO 9001 3.4 lbs [1.55 kg] 2.9” [72.9] GMB(X)24-SR Power supply 4.55” [115.6] Technical Data The GMB(X) series provides 95° of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. GMB(X)24-SR Proportional, Non-Spring Return, 24 V, for 2 to 10 VDC or 4 to 20 mA Accessories Wiring Diagrams 1/2”-1.05 [12.7 to 26.67 mm] Shaft Clamp Multiple Actuator Mounting Bracket GM to GM Retrofit Mounting Bracket Crank arm Adaptor Kit Jackshaft Adaptors for Hollow Jackshafts Weather Shield - Steel Weather Shield - Polycarbonate Explosion Proof Housing NEMA 4X Housing 13 mm Wrench Actuator Power Supply Simulator Auxiliary Switch (es) Shaft Mount Auxiliary Switch Feedback Potentiometers Min positioners in NEMA 4 housing Min positioners for flush panel mounting Pulse Width Modulation Interface Input Rescaling Module Analog to Digital Switch Resistor for 4 to 20 mA Conversion Battery Back-Up Module Transformer 1 Provide overload protection and disconnect as required. 2 CAUTION Equipment Damage! 3 Actuators may also be powered by 24 VDC. 5 Only connect common to neg. (–) leg of control circuits. Actuators may be connected in parallel. Power consumption and input impedance must be observed. Meets UL requirements without the need of an electrical ground connection. The ZG-R01 500 Ω resistor converts the 4 to 20 mA control signal to 2 to 10 VDC, up to 2 actuators may be connected in parallel. WARNING G Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. NOTE: When using GMB(X)24-SR… actuators, only use accessories listed on this page. W253_08 K-GM20 ZG-102 Z-GMA ZG-GMA ZG-JSA (-1, 2, 3) ZS-100 ZS-150 ZS-260 ZS-300 (-1) (-5) Tool-07 PS-100 S1A, S2A P370 P…A SGA24 SGF24 PTA-250 IRM-100 ADS-100 ZG-R01 NSV24 US ZG-X40 Proportional control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05” diameter. Actuators must provide proportional damper control in response to a 2 to 10 VDC or, with the addition of a 500 Ω resistor, a 4 to 20 mA control input from an electronic controller or positioner. Actuators shall have Brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. A 2 to 10 VDC feedback signal shall be provided for position indication. Actuators shall be cULus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. 2 to 10 VDC control W253_08 M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. Typical Specification 4 to 20 mA control 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 196 GMB24-SR-T N4 NEMA 4, Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 mA Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft. Application For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer’s specifications. The actuator is mounted directly to a damper shaft up to 1.05" in diameter by means of its universal clamp. The actuator operates in response to a 2 to 10 VDC, or with the addition of a 500 Ω resistor, a 4 to 20 mA control input from an electronic controller or positioner. A 2 to 10 VDC feedback signal is provided for position indication or master-slave applications. Operation The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. Overload protection Operating range Y Input impedance Angle of rotation Torque Direction of rotation Position indication Running time Humidity Ambient temperature Storage temperature Housing Housing material Agency listings† Noise level Servicing Quality standard Weight switch reversible with dial 150 seconds constant independent of load 5 to 100% RH (UL Type 4) -22°F to 122°F [-30°C to 50°C] -40°F to 176°F [-40°C to 80°C] UL Type 4X, NEMA 4X, IP66 polycarbonate cULus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1, CSA C22.2 No. 24-93, CE acc. to 89/336/EEC <45dB(A) maintenance free ISO 9001 9.8 lbs [4.45 kg] The GMB24-SR-T N4 actuator uses a sensorless brushless DC motor, which is controlled by an Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. Dimensions (inches [mm]) 172 [6.77] †Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3. 800-543-9038 USA 197 866-805-7089 CANADA 203-791-8396 LATIN AMERICA M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. Power consumption Transformer Sizing Electrical connection GMB24-SR-T N4 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% 4.5 W (2.0 W) 6.5 VA (Class 2 power source) screw terminal (for 26 to 14 GA wire) ½” conduit connector electronic throughout 0 to 95° rotation 2 to 10 VDC, 4 to 20 mA 100 kΩ (0.1 mA), 500 Ω max. 95°, adjustable with mechanical stop 360 in-lb [40 Nm] D312 Technical Data Power supply The GMB24-SR-T N4 provides 95° of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator after the cover is removed. GMB24-SR-T N4 NEMA 4, Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 mA Wiring Diagrams Accessories S1A, S2A P…A SGA24 SGF24 PTA-250 IRM-100 ADS-100 ZG-R01 NSV24 US ZG-X40 43442-00001 11097-00001 Auxiliary Switch (es) Feedback Potentiometers Min positioners for surface mounting Min positioners for flush panel mounting Pulse Width Modulation Interface Input Rescaling Module Analog to Digital Switch Resistor for 4 to 20 mA Conversion Battery Back-Up Module Transformer Gland* Gasket for Gland* 1 Provide overload protection and disconnect as required. 2 CAUTION N Equipment Damage! 3 Actuators may also be powered by 24 VDC. 5 Only connect common to neg. (–) leg of control circuits NOTE: When using GMB24-SR-T N4 actuators, only use accessories listed on this page. * Both parts are needed when using an auxiliary switch or potentiometer with GMB24-SR-T N4 Actuators may be connected in parallel. Power consumption and input impedance must be observed. The ZG-R01 500 Ω resistor converts the 4 to 20 mA control signal to 2 to 10 VDC, up to 2 actuators may be connected in parallel. WARNING G Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Typical Specification Proportional control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05” diameter. Actuators must provide proportional damper control in response to a 2 to 10 VDC or, with the addition of a 500 Ω resistor, a 4 to 20 mA control input from an electronic controller or positioner. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover of the actuator. Run time shall be constant and independent of torque. A 2 to 10 VDC feedback signal shall be provided for position indication. Actuators shall be cULus listed, NEMA 4X, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. AMB24-SR-T N4 2 to 10 VDC control AMB24-SR-T N4 4 to 20 mA control 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 198 GMB(X)24-MFT Proportional, Non-Spring Return, 24 V, Multi-Function Technology® T Torque min. i 360 in-lb i lb for f controll off damper d surfaces f up to 90 sq ft. f Application For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer’s specifications. The actuator is mounted directly to a damper shaft up to 1.05” in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. The default parameters for 2 to 10 VDC applications of the …MFT actuator are assigned during manufacturing. If necessary, custom versions of the actuators can be ordered. The parameters can be changed by two means: pre-set and custom configurations from Belimo or on-site configurations using the Belimo PC-Tool software. Operation The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. Power consumption Transformer sizing Electrical connection Overload protection Operating range Y Input impedance Feedback output U Angle of rotation Torque Direction of rotation Position indication Manual override Running time Humidity Ambient temperature Storage temperature Housing Housing material Agency listings† Noise level Servicing Quality standard Weight The GMB(X)24-MFT actuators use a brushless DC motor, which is controlled by an Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. Dimensions (Inches [mm]) 1/2” to 1.05” [12.7 to 26.67] 2/5” to 1.05” [10 to 26.67] 5.37” [136.4] To center of mounting slot. 7.02” [178.4] 1.42” [36] 5.6” [142.4] 2” [50.8] †Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3. 800-543-9038 USA 199 866-805-7089 CANADA 203-791-8396 LATIN AMERICA M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% 4.5 W (1.5 W) 7 VA (Class 2 power source) 18 GA plenum rated cable 1/2” conduit connector protected NEMA 2 (IP54) 3 ft [1m] 10 ft [3m] 16 ft [5m] electronic throughout 0 to 95° rotation 2 to 10 VDC, 4 to 20 mA (default) variable (VDC, PWM, floating point, on/off) 100 kΩ (0.1 mA), 500 Ω 1500 Ω (PWM, floating point, on/off) 2 to 10 VDC, 0.5 mA max VDC variable max. 95°, adjustable with mechanical stop electronically variable 360 in-lb [40 Nm] reversible with switch reflective visual indicator (snap-on) external push button 150 seconds (default) variable (75 to 300 seconds) 5 to 95% RH non condensing (EN 60730-1) -22°F to +122°F [-30°C to +50°C] -40°F to +176°F [-40°C to +80°C] NEMA 2, IP54, UL enclosure type 2 UL94-5VA cULus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EEC and 2006/95/EC <45dB(A) maintenance free ISO 9001 3.4 lbs [1.55 kg] D123 Power supply The GMB(X) series provides 95° of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. 2.9” [72.9] GMB(X)24-MFT 4.55” [115.6] Technical Data GMB(X)24-MFT Proportional, Non-Spring Return, 24 V, Multi-Function Technology® Accessories WARNING G Live Electrical Components! 3/4" [20 mm] Shaft Clamp Multiple Actuator Mounting Bracket Crank arm Adaptor Kit Jackshaft Adaptors for Hollow Jackshafts Weather Shield - Steel Weather Shield - Polycarbonate Explosion Proof Housing NEMA 4X Housing 13 mm Wrench Actuator Power Supply Simulator Auxiliary Switch (es) Shaft Mount Auxiliary Switch Feedback Potentiometers Min positioners in NEMA 4 housing Min positioners for flush panel mounting Analog to Digital Switch Resistor for 4 to 20 mA Conversion Battery Back-Up Module Transformer During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. W399_08 K-GM20 ZG-102 ZG-GMA ZG-JSA (-1, 2, 3) ZS-100 ZS-150 ZS-260 ZS-300 (-1) (-5) Tool-07 PS-100 S1A, S2A P370 P…A SGA24 SGF24 ADS-100 ZG-R01 NSV24 US ZG-X40 NOTE: When using GMB(X)24-MFT actuators, only use accessories listed on this page. W399_08 VDC/4-20 mA Typical Specification Proportional control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05” diameter. Actuators must provide proportional damper control in response to a 2 to 10 VDC or, with the addition of a 500 Ω resistor, a 4 to 20 mA control input from an electronic controller or positioner. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. Actuators shall be cULus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. W399_08 PWM M 1 2 3 4 5 8 9 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. Actuators may also be powered by 24 VDC. Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) or the Common (sink) 24 VAC line. Contact closures A & B also can be triacs. A & B should both be closed for triac source and open for triac sink. For triac sink the common connection from the actuator must be connected to the hot connection of the controller. On/Off Off controll W399_08 M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. Wiring Diagrams Meets UL requirements without the need of an electrical ground connection. The ZG-R01 500 Ω resistor may be used. Floating Point control 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 200 GMX24-MFT-T N4 NEMA 4, Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology® Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft. Application For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer’s specifications. The actuator is mounted directly to a damper shaft up to 1.05" in diameter by means of its universal clamp. The default parameters for 2 to 10 VDC applications of the …MFT actuator are assigned during manufacturing. If necessary, custom versions of the actuators can be ordered. The parameters can be changed by two means: pre-set and custom configurations from Belimo or on-site configurations using the Belimo PC-Tool software. Operation The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. The GMX24-MFT-T N4 provides 95° of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator after the cover is removed. Input impedance Feedback output U Angle of rotation Torque Direction of rotation Position indication Running time Humidity Ambient temperature Storage temperature Housing Housing material Agency listings† Noise level Servicing Quality standard Weight Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. Dimensions (inches [mm]) reversible with switch dial 150 seconds (default) variable (45 to 170 seconds) 5 to 100% RH (UL Type 4) -22°F to 122°F [-30°C to 50°C] -40°F to 176°F [-40°C to 80°C] UL Type 4X, NEMA 4X, IP66 polycarbonate cULus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1, CSA C22.2 No. 24-93, CE acc. to 89/336/EEC <45dB(A) maintenance free ISO 9001 10 lbs [4.56 kg] †Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3. 800-543-9038 USA 201 866-805-7089 CANADA 203-791-8396 LATIN AMERICA M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. Overload protection Operating range Y The GMX24-MFT-T N actuators use a brushless DC motor, which is controlled by an Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition.Power consumption is reduced in holding mode. D312 Power consumption Transformer sizing Electrical connection GMX24-MFT-T N4 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% 4.0 W (2.0 W) 7 VA (Class 2 power source) screw terminal (for 26 to 14 GA wire) ½” conduit connector electronic throughout 0 to 95° rotation 2 to 10 VDC, 4 to 20 mA (default) variable (VDC, floating point, on/off) 100 kΩ (0.1 mA), 500 Ω 1500 Ω (PWM, floating point, on/off) 2 to 10 VDC, 0.5 mA max, VDC variable max. 95°, adjustable with mechanical stop electronically variable 360 in-lb [40 Nm] 172 [6.77] Technical Data Power supply GMX24-MFT-T N4 Accessories S1A, S2A P…A SGA24 SGF24 ADS-100 ZG-R01 NSV24 US ZG-X40 43442-00001 11097-00001 W399_08 NEMA 4, Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology® Auxiliary Switch (es) Feedback Potentiometers Min positioners for surface mounting Min positioners for flush panel mounting Analog to Digital Switch Resistor for 4 to 20 mA Conversion Battery Back-Up Module Transformer Gland* Gasket for Gland* NOTE: When using GMX24-MFT-T N4 actuators, only use accessories listed on this page. * Both parts are needed when using an auxiliary switch or potentiometer with GMX24-MFT-T N4 W399_08 VDC/4-20 mA Typical Specification PWM M W399_08 Proportional control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05” diameter. Actuators must provide proportional damper control in response to a 2 to 10 VDC or, with the addition of a 500 Ω resistor, a 4 to 20 mA control input from an electronic controller or positioner. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover of the actuator. Run time shall be constant and independent of torque. Actuators shall be cULus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. 1 Provide overload protection and disconnect as required. 2 CAUTION N Equipment Damage! 3 4 5 8 9 Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. On/Off control W399_08 M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. Wiring Diagrams Actuators may also be powered by 24 VDC. Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) or the Common (sink) 24 VAC line. Contact closures A & B also can be triacs. A & B should both be closed for triac source and open for triac sink. For triac sink the common connection from the actuator must be connected to the hot connection of the controller. The ZG-R01 500 Ω resistor may be used. Floating Point control WARNING G Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 202 GMX24-MFT95 Proportional, Non-Spring Return, 24 V, 0 to 135 Ω Input T Torque min. i 360 in-lb i lb for f controll off damper d surfaces f up to 90 sq ft. f Application For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer’s specifications. The actuator is mounted directly to a damper shaft up to 1.05” in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. The default parameters for 0 to 135Ω input applications of the …MFT95 actuator are assigned during manufacturing. If necessary, custom versions of the actuators can be ordered. The parameters can be changed by two means: pre-set and custom configurations from Belimo or on-site configurations using the Belimo PC-Tool software. Operation The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. Power consumption Transformer sizing Electrical connection Overload protection Operating range WRB Feedback output U Angle of rotation Torque Direction of rotation Position indication Manual override Running time Humidity Ambient temperature Storage temperature Housing Housing material Agency listings† Noise level Servicing Quality standard Weight The GMX24-MFT95 actuators use a brushless DC motor, which is controlled by an Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. Dimensions (Inches [mm]) 1/2” to 1.05” [12.7 to 26.67] 2/5” to 1.05” [10 to 26.67] 5.37” [136.4] To center of mounting slot. 7.02” [178.4] 1.42” [36] 5.6” [142.4] 2” [50.8] †Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3. 800-543-9038 USA 203 866-805-7089 CANADA 203-791-8396 LATIN AMERICA M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% 4.5 W (1.5 W) 7 VA (Class 2 power source) 18 GA plenum rated cable 1/2” conduit connector protected NEMA 2 (IP54) 3 ft [1m] electronic throughout 0 to 95° rotation 135 Ω Honeywell Electronic Series 90, 0 to 135 Ω input 2 to 10 VDC, 0.5 mA max VDC variable max. 95°, adjustable with mechanical stop electronically variable 360 in-lb [40 Nm] reversible with switch reflective visual indicator (snap-on) external push button 150 seconds (default) variable (100 to 280 seconds) 5 to 95% RH non condensing (EN 60730-1) -22°F to 122°F [-30°C to 50°C] -40°F to 176°F [-40°C to 80°C] NEMA 2, IP54, UL enclosure type 2 UL94-5VA cULus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EEC and 2006/95/EC <45dB(A) maintenance free ISO 9001 3.4 lbs [1.55 kg] D123 Power supply The GMX series provides 95° of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. 2.9” [72.9] GMX24-MFT95 4.55” [115.6] Technical Data GMX24-MFT95 Proportional, Non-Spring Return, 24 V, 0 to 135 Ω Input Accessories K-GM20 ZG-102 ZG-GMA ZG-JSA (-1, 2, 3) ZS-100 ZS-150 ZS-260 ZS-300 (-1) (-5) Tool-07 PS-100 S1A, S2A P370 P…A NSV24 US ZG-X40 Wiring Diagrams 1/2”-1.05 [12.7 to 26.67 mm] Shaft Clamp Multiple Actuator Mounting Bracket Crank arm Adaptor Kit Jackshaft Adaptors for Hollow Jackshafts Weather Shield - Steel Weather Shield - Polycarbonate Explosion Proof Housing NEMA 4X Housing 13 mm Wrench Actuator Power Supply Simulator Auxiliary Switch (es) Shaft Mount Auxiliary Switch Feedback Potentiometers Battery Back-Up Module Transformer 5 Actuators with plenum rated cable do not have numbers on wires; use color codes instead. Actuators with appliance cables are numbered. 21 Provide overload protection and disconnect as required. 222 Actuators and controller must have separate transformers. 233 Consult controller instruction data for more detailed information. 244 Resistor value depends on the type of controller and the number of actuators. No resistor is used for one actuator. Honeywell® resistor kits may also be used. 255 To reverse control rotation, use the reversing switch. Typical Specification 24 VAC Transformer 21 Proportional control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05” diameter. Actuators must provide proportional damper control in response to 0 to 135 Ω input from an electronic controller or positioner. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. Actuators shall be cULus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. S963A Minimum Position Potentiometer Line 5 Blk (1) Common Volts Red (2) + Hot 25 Series 90 Controller B R R 22 B W Pnk (4) Wht (3) Gry (5) Org (6) W Shunting Resistor Wnew60408_6 NOTE: When using GMX24-MFT95 actuators, only use accessories listed on this page. 23 24 W R B ‘U5’ Output 2 to 10 VDC -MFT95 B R W H205 Change- Occupied over Controller Contact Wire Colors 3 = White 4 = Pink 5 = Gray 6 = Orange 21 Line Blk (1) Common Volts Line Blk (1) Common Volts To other actuators Red (2) + Hot R B ‘U5’ Output 2 to 10 VDC -MFT95 B Gry (5) Wiring multiple actuators to a Series 90 controller using a minimum position potentiometer. B 24 VAC Transformer 21 Org (6) ‘U5’ Output 2 to 10 VDC 5 Line -MFT95 21 24 VAC Transformer Blk (1) Common Volts Line W016 24 Wht (3) R Red (2) + Hot 23 Blk (1) Common Volts Red (2) + Hot 22 23 Series 90 Controller A Line Volts W Pnk (4) W R Wht (3) R B Controller B Wnew60408_6 Pnk (4) W 135 Ω 23 25 W 23 A 22 Pnk (4) Wht (3) Gry (5) Org (6) 24 W W R B R Wht (3) R B Gry (5) B Series 90 low limit control 135 Ω for 0 to 50% control 280 Ω for 0 to 100% control Gry (5) B Org (6) ‘U5’ Output 2 to 10 VDC Pnk (4) W 24 Org (6) ‘U5’ Output 2 to 10 VDC -MFT95 Low Limit Control -MFT95 5 24 VAC Transformer 21 Override W017 M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. Wnew60408_6 5 21 24 VAC Transformer Red (2) + Hot 22 Wnew60408_6 1 = Black 2 = Red Line Blk (1) Common Volts Red (2) + Hot 23 22 Series 90 Controller W Pnk (4) W R Wht (3) R B R W B 24 Gry (5) B Org (6) ‘U5’ Output 2 to 10 VDC Series 90 high limit control - 280 Ω -MFT95 High Limit Control 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 204 GMX24-PC Proportional, Non-Spring Return, 24 V, 0 to 20 V Phasecut T Torque min. i 360 in-lb i lb for f controll off damper d surfaces f up to 90 sq ft. f Application For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer’s specifications. The actuator is mounted directly to a damper shaft up to 1.05” in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled (only the positive part of the sine wave) to the damper shaft. The actuator operates in response to 0 to 20V phasecut control input only on the positive part of the sine wave from an electronic controller or positioner. A 2 to 10 VDC feedback signal is provided for position indication. Operation The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. Overload protection Operating range Y Input impedance Feedback output U Angle of rotation Torque Direction of rotation Position indication Manual override Running time Humidity Ambient temperature Storage temperature Housing Housing material Agency listings† Noise level Servicing Quality standard Weight The GMX24-PC actuators use a brushless DC motor, which is controlled by an Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. Dimensions (Inches [mm]) 1/2” to 1.05” [12.7 to 26.67] 2/5” to 1.05” [10 to 26.67] 5.37” [136.4] To center of mounting slot. 7.02” [178.4] 1.42” [36] 5.6” [142.4] 2” [50.8] †Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3. 800-543-9038 USA 205 866-805-7089 CANADA 203-791-8396 LATIN AMERICA M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. Power consumption Transformer sizing Electrical connection D123 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% 4.5 W (1.5 W) 7 VA (Class 2 power source) 18 GA plenum rated cable 1/2” conduit connector protected NEMA 2 (IP54) 3 ft [1m] electronic throughout 0 to 95° rotation 0 to 20 V phasecut control is only for the postiive part of the sine wave (max of 10 volts) 8 kΩ (50 mW) 2 to 10 VDC, 0.5 mA max max. 95°, adjustable with mechanical stop electronically variable 360 in-lb [40 Nm] reversible with switch reflective visual indicator (snap-on) external push button 150 seconds (default) 5 to 95% RH non condensing (EN 60730-1) -22°F to 122°F [-30°C to 50°C] -40°F to 176°F [-40°C to 80°C] NEMA 2, IP54, UL enclosure type 2 UL94-5VA cULus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EEC and 2006/95/EC <45dB(A) maintenance free ISO 9001 3.4 lbs [1.55 kg] 2.9” [72.9] GMX24-PC Power supply 4.55” [115.6] Technical Data The GMX series provides 95° of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. GMX24-PC Proportional, Non-Spring Return, 24 V, 0 to 20 V Phasecut Accessories K-GM20 ZG-102 ZG-GMA ZG-JSA (-1, 2, 3) ZS-100 ZS-150 ZS-260 ZS-300 (-1) (-5) Tool-07 PS-100 S1A, S2A P370 P…A NSV24 US ZG-X40 1/2”-1.05 [12.7 to 26.67 mm] Shaft Clamp Multiple Actuator Mounting Bracket Crank arm Adaptor Kit Jackshaft Adaptors for Hollow Jackshafts Weather Shield - Steel Weather Shield - Polycarbonate Explosion Proof Housing NEMA 4X Housing 13 mm Wrench Actuator Power Supply Simulator Auxiliary Switch (es) Shaft Mount Auxiliary Switch Feedback Potentiometers Battery Back-Up Module Transformer Provide overload protection and disconnect as required. 1 CAUTION Equipment Damage! 2 Actuators may be connected in parallel. Power consumption and input impedance must be observed. Actuators may also be powered by 24 VDC. 3 Meets UL requirements without the need of an electrical ground connection. WARNING G Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. NOTE: When using GMX24-PC actuators, only use accessories listed on this page. Proportional control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05” diameter. Actuators must provide proportional damper control in response to 0 to 20 V phasecut control input from an electronic controller or positioner. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. Actuators shall be cULus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. W185 Typical Specification 1 24 VAC Transformer Line Volts Blk (1) Common – Red (2) Hot + 3 Pnk (6) Y Input, 0 to 20V phasecut Control Signal (–) 0 to 20 V Phasecut (+) Wiring Diagram Org (5) U Output, 2 to 10V …PC 2 M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. Proportional Control 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 206 GMX24-LON LonWorks®, Non-Spring Return, 24 V T Torque min. i 360 in-lb i lb for f controll off damper d surfaces f up to 90 sq ft. f Application Direct coupled actuators for direct link to LonWorks network. Actuators are easily installed by direct shaft mounting on air dampers in ventilation and air conditioning systems. Actuator can be controlled by any compatible LON system. For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer’s specifications. The actuator is mounted directly to a damper shaft up to 1.05” in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. Operation The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. The GMX24-LON series provides 95° of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. Overload protection Angle of rotation Torque Direction of rotation Position indication Manual override Running time Humidity Ambient temperature Storage temperature Housing Housing material Agency listings† Noise level Servicing Quality standard Weight Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. Dimensions (Inches [mm]) 1/2” to 1.05” [12.7 to 26.67] 2/5” to 1.05” [10 to 26.67] 5.37” [136.4] To center of mounting slot. 7.02” [178.4] †Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3. 1.42” [36] LonWorks® 5.6” [142.4] 2” [50.8] according to LonMARK® 3.3 Neuron 3120 FTT-10A, compatible with LPT-10 according to LonMARK® Damper actuator object #8110 open loop sensor object #1 LNS plug-in for actuator/sensor can be run with any LNS based integration tool (min. for LNS 3.x) Service button and status LED according to LonMARK® guidelines Conductors, cables conductor lengths, cable specifications and topology of the LonWorks® network according to the Echelon® directives Certified Processor Transceiver Functional profile LonWorks and LonMARK © 2007-2009 LonMark International 800-543-9038 USA 207 866-805-7089 CANADA 203-791-8396 LATIN AMERICA M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. Power consumption Transformer sizing Electrical connection The GMX24-LON actuators use a brushless DC motor, which is controlled by an Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. D123 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% 4.5 W (1.5 W) 7 VA (Class 2 power source) 18 GA plenum rated cable 1/2” conduit connector protected NEMA 2 (IP54) 3 ft [1m] electronic throughout 0 to 95° rotation max. 95°, adjustable with mechanical stop electronically variable 360 in-lb [40 Nm] reversible with switch reflective visual indicator (snap-on) external push button 150 seconds (default) 5 to 95% RH non condensing (EN 60730-1) -22°F to +122°F [-30°C to +50°C] -40°F to +176°F [-40°C to +80°C] NEMA 2, IP54, UL enclosure type 2 UL94-5VA cULus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EEC and 2006/95/EC <45dB(A) maintenance free ISO 9001 3.4 lbs [1.55 kg] 2.9” [72.9] GMX24-LON Power supply 4.55” [115.6] Technical Data GMX24-LON ® Accessories T 1 2 T ~ + – 5 6 7 LON 3 LON + – MFT 3/4" [20 mm] Shaft Clamp Multiple Actuator Mounting Bracket Crank arm Adaptor Kit Jackshaft Adaptors for Hollow Jackshafts Weather Shield - Steel Weather Shield - Polycarbonate Explosion Proof Housing NEMA 4X Housing 13 mm Wrench Actuator Power Supply Simulator Auxiliary Switch (es) Shaft Mount Auxiliary Switch Feedback Potentiometers Min positioners in NEMA 4 housing Min positioners for flush panel mounting Analog to Digital Switch Battery Back-Up Module Transformer ~ Sensor scaling: The sensors can be scaled with the sensor plug-in (sensor table). NOTE: When using GMX24-LON actuators, only use accessories listed on this page. Typical Specification Sensor Temperature range Resistance range Resolution Ni1000 –28 ... +98°C 850 ... 1600 Ω 1Ω PT1000 –35 ... +155°C 850 ... 1600 Ω 1Ω –10 ... +160°C (depending on type) 200 ... 60 kΩ 1Ω NTC – Schema_LON_03 Connection with Passive Sensor, e.g. Pt1000, Ni1000, NTC T Proportional control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05” diameter. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. Actuators shall be cULus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. ~ K-GM20 ZG-102 ZG-GMA ZG-JSA (-1, 2, 3) ZS-100 ZS-150 ZS-260 ZS-300 (-1) (-5) Tool-07 PS-100 S1A, S2A P370 P…A SGA24 SGF24 ADS-100 NSV24 US ZG-X40 Schema_LON_02 LonWorks , Non-Spring Return, 24 V + Wiring Diagrams 2 5 6 7 T ~ 6 7 LON LON Connection with Switching Contact, e.g. Δp-monitor + LON – LON + MFT – + 5 MFT Schema_LON_01 3 3 Schema_LON_04 1 – T Connection without Sensor T – + 3 5 6 7 Sensor scaling: The sensors can be scaled with the sensor plug-in (sensor table) LON 2 LON 1 MFT Possible input voltage range: 0 ... 32 V (resolution 30 mV) ~ M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. V Possible connection of a voltmeter for checking the position feedback U. 2 ~ T V 1 T + ~ ~ – Requirements for switching contact: The switching contact must be able to accurately switch a current of 16 mA @ 24 V. Connection with Active Sensor, e.g. 0...10 V @ 0...50° C 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 208 GMX24-LON LonWorks®, Non-Spring Return, 24 V Functional Profile according to LonMARK K® The LON-capable damper actuator is certified by LonMARK®. The actuator functions are supplied with the LonWorks® network as standardized network variables according to LonMARK®. The Node Object #0, the Damper Actuator Object #8110 and the Open Loop SensorObject #1 are implemented in the actuator. Node object #0 The node object contains the object status and object request functions. nviRequest SNVT_obj_request Input variable for requesting the status of a particular object in the node. nvoStatus SNVT_obj_status Output variable that outputs the current status of a particular object in the node. nvoFileDirectory SNVT_address Output variable that shows information in the address range of the Neuron chip. Damper actuator object #8110 The actuator object is used to map the functions of the MP actuators to the LONWORKS® network. nviRelStpt SNVT_lev_percent The nominal position is assigned to the actuator via this input variable. This variable is normally linked to the output variable of an HVAC controller. nviActuateState SNVT_switch A preset position is assigned to the actuator via this input variable. Note on priority: The last variable that was active, either nviActuatorState or nviRelStpt, has priority. nviManOvrd SNVT_hvac_overid These input variables can be used to manually override the actuator into a particular position. nvoActualValue SNVT_lev_percent This output variable shows the current actual position of the actuator and can be used for control circuit feedback or for displaying positions. nvoAbsAngle SNVT_angle_deg This output variable shows the current angle of rotation of the actuator or the valve and can be used to display the position or for service purposes. Open loop sensor object #1 A sensor can be connected to the rotary actuator. A passive resistance sensor (e.g. Ni1000), an active sensor (output 0 ... 32 V) or a switch (on/off) can be connected. The open loop sensor object transfers the measured sensor values to the LONWORKS® network. nvoSensorValue SNVT_xxx This output variable shows the current sensor value. Depending on the connected sensor, the output variable can be configured via the sensor plug-in and specifically adapted to the system. The SNVT_... can be configured as: SNVT_temp_p SNVT_lev_percent SNVT_lux SNVT_temp SNVT_abs_humid SNVT_press_p SNVT_switch SNVT_enthalpy SNVT_smo_obscur SNVT_flow SNVT_ppm SNVT_power SNVT_flow_p SNVT_rpm SNVT_elec_kwh Notes Detailed information on the functional profiles can be found on the website of LonMARK K® (www.lonmark.org). 800-543-9038 USA 209 866-805-7089 CANADA 203-791-8396 LATIN AMERICA M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. nvoAbsAirFlow SNVT_flow This output variable is inactive with the SR24ALON-5 rotary actuator and shows a constant value of 65535 (this variable is only active in conjunction with LON-capable VAV controllers). GMX24-LON ® LonWorks , Non-Spring Return, 24 V 1 2 3 4 M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc. 5 1 Direction of rotation switch Switching over Direction of rotation changes 2 Pushbutton and green LED display Off No voltage supply or malfunction Operation Green, on Press button Switches on angle of rotation adaption followed by standard operation 3 Service button for commissioning LONWORKS® and yellow LED display for the LON status Off The SR24ALON-5 rotary actuator is connected and ready for operation in the LONWORKS®network. Yellow, on No application software is loaded in the SR24ALON-5. Yellow, flashing The SR24ALON-5 is ready for operation but not (flashing interval 2 seconds) integrated in the LONWORKS® network (unconfigured). Other flashing codes A fault is present in the SR24ALON-5. Press button Service Pin Message is sent to the LONWORKS®network. 4 Gear disengagement switch Press button Gear disengaged, motor stops, manual operation possible Release button Gear engaged, synchronisation starts, followed by standard operation 5 Service plug For connecting MFT parameterizing and service tools 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 210