GMB Series

advertisement
GM Series Direct Coupled Actuator
Minimum 360 in-lb Torque
For damper areas up to 90 sq-ft*
Wiring
Auxiliary Switch
Variable (0 to 10 VDC)
150 seconds
Adj. 75 to 280 seconds
Plenum Rated Cable
Appliance Rated Cable
Conduit Fitting
Add-On
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Installation and Operations…(page 269).
*Based on 4 in-lb/ft2 damper torque loading. Parallel blade. No edge seals.
800-543-9038 USA
187
207)
GMX24-
●
●
●
®
None
2 to 10 VDC
LON (p.
05)
PC (p. 2
GMX24-
MFT95
(p. 203)
4 (p. 201
MFT-T N
. 199)
GMB(X)2
4-MFT (p
GMB24-
SR-T N4
. 195)
4-SR (p
3)
-3 (p. 19
GMX120
3-T N4
●
●
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
Running Time
●
GMX24-
360 in-lb [40 Nm]
95 degrees
24 VAC/DC
100 to 240 VAC
On/Off, Floating Point
2 to 10 VDC (4 to 20mA)
Multi-Function Technology
0 to 135 Ohm
0 to 20V Phasecut
●
●
●
LonWORKS
Feedback
●
GMX24-
Control Input
●
GMB(X)2
Basic Product
Flexible Product
Torque
Angle of Rotation
Power Supply
GMB24-
GM Series - At A Glance
GMB(X)2
4-3 (p. 1
89)
(p. 191)
Actuators in
bold have BDCM
(p. 197)
)
●
GM Series Direct Coupled Actuator
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
A CLOSER LOOK…
●
Brushless DC Motor for Added Accuracy and Controllability.
●
Cut Labor Costs with Simple Direct Coupling.
●
Self-Centers on 1.05" or 3/4” with the Standard Clamp.
●
Check Damper Position with Clear Position Indicator.
●
Don’t Worry about Actuator Burn-Out; Belimo is Overload Proof
throughout Rotation.
●
Enjoy Added Flexibility with Easy Mechanical Stops
to Adjust Angle of Rotation.
●
Need to Change Control Direction?
Do it easily with a Simple Switch.
●
Easily Accessible Manual Override Button
helps you Pre-Tension Damper Blades.
●
Auxiliary Switch and Feedback Potentiometer Add-Ons Mount
Directly on Clamp, Includes Conduit Connector.
●
Standard 3ft Plenum Rated Cable and Conduit Connector Provided
on Basic Models.
●
Added Flexibility to Select Clamp, Electrical Connection, and
Running Time to fit your Specific Application with Belimo’s New
Flexible Line of Actuators.
The Belimo Difference
●
Customer Commitment.
Extensive product range. Application assistance.
Same-day shipments. Free technical support. Five year warranty.
●
Low Installation and Life-Cycle Cost.
Easy installation. Accuracy and repeatability.
Low power consumption. No maintenance.
●
Long Service Life.
Components tested before assembly. Every product tested before shipment.
30+ years direct coupled actuator design.
800-543-9038 USA
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
188
GMB(X)24-3
On/Off, Floating Point, Non-Spring Return, 24 V
Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft.
Application
For on/off and floating point control of dampers in HVAC systems. Actuator sizing
should be done in accordance with the damper manufacturer’s specifications.
The actuator is mounted directly to a damper shaft up to 1.05” in diameter by means
of its universal clamp. A crank arm and several mounting brackets are available for
applications where the actuator cannot be direct coupled to the damper shaft.
Operation
The actuator is not provided with and does not require any limit switches, but is
electronically protected against overload. The anti-rotation strap supplied with the
actuator will prevent lateral movement.
The GMB(X) series provides 95° of rotation and a visual indicator indicates position of
the actuator. When reaching the damper or actuator end position, the actuator
automatically stops. The gears can be manually disengaged with a button on the
actuator cover.
Overload protection
Control
Input impedance
Angle of rotation
Torque
Direction of rotation
Position indication
Manual override
Running time
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency listings†
Noise level
Servicing
Quality standard
Weight
Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto
the actuator body for signaling and switching functions.
Dimensions (Inches [mm])
1/2” to 1.05” [12.7 to 26.67]
2/5” to 1.05” [10 to 26.67]
5.37” [136.4]
To center of
mounting slot.
7.02” [178.4]
1.42”
[36]
5.6” [142.4]
2” [50.8]
†Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3.
800-543-9038 USA
189
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
Power consumption
Transformer sizing
Electrical connection
D123
24 VAC ± 20% 50/60 Hz
24 VDC ± 10%
4 W (2 W)
6 VA (Class 2 power source)
18 GA plenum rated cable
1/2” conduit connector
protected NEMA 2 (IP54)
3 ft [1m] 10 ft [3m] 16 ft [5m]
electronic throughout 0 to 95° rotation
on/off, floating point
600 Ω
max. 95°, adjustable with mechanical stop
360 in-lb [40 Nm]
reversible with
switch
reflective visual indicator (snap-on)
external push button
150 seconds, constant independent of load
5 to 95% RH non condensing (EN 60730-1)
-22°F to +122°F [-30°C to +50°C]
-40°F to +176°F [-40°C to +80°C]
NEMA 2, IP54, UL enclosure type 2
UL94-5VA
cULus acc. to UL 60730-1A/-2-14,
CAN/CSA E60730-1:02,
CE acc. to 2004/108/EEC and 2006/95/EC
<45dB(A)
maintenance free
ISO 9001
3.4 lbs [1.55 kg]
2.9” [72.9]
GMB(X)24-3
Power supply
4.55” [115.6]
Technical Data
The GMB(X)24-3... actuators use a brushless DC motor, which is controlled by an
Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the
actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent
damage to the actuator in a stall condition. Power consumption is reduced in holding
mode.
GMB(X)24-3
On/Off, Floating Point, Non-Spring Return, 24 V
Accessories
K-GM20
ZG-102
Z-GMA
ZG-GMA
ZG-JSA (-1, 2, 3)
ZS-100
ZS-150
ZS-260
ZS-300 (-1) (-5)
Tool-07
S1A, S2A
P370
P…A
Wiring Diagrams
1/2”-1.05 [12.7 to 26.67 mm] Shaft Clamp
Multiple Actuator Mounting Bracket
GM to GM Retrofit Mounting Bracket
Crank arm Adaptor Kit
Jackshaft Adaptors for Hollow Jackshafts
Weather Shield - Steel
Weather Shield - Polycarbonate
Explosion Proof Housing
NEMA 4X Housing
13 mm Wrench
Auxiliary Switch (es)
Shaft Mount Auxiliary Switch
Feedback Potentiometers
1
Provide overload protection and disconnect as required.
3
Actuators may also be powered by 24 VDC.
Meets cULus requirements without the need of an electrical ground connection.
WARNING
G Live Electrical Components!
During installation, testing, servicing and troubleshooting of this product, it may be
necessary to work with live electrical components. Have a qualified licensed electrician or other
individual who has been properly trained in handling live electrical components perform these
tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury.
NOTE: When using GMB(X)24-3... actuators, only use accessories listed on this page.
Typical Specification
W254_08
Floating point, on/off control damper actuators shall be electronic direct-coupled type,
which require no crank arm and linkage and be capable of direct mounting to a shaft
up to 1.05” diameter. Actuators shall have brushless DC motor technology and be
protected from overload at all angles of rotation. Actuators shall have reversing switch
and manual override on the cover. Run time shall be constant and independent of
torque. Actuators shall be cULus listed, have a 5-year warranty, and be manufactured
under ISO 9001 International Quality Control Standards. Actuators shall be as
manufactured by Belimo.
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
W255_08
On/Off control
Floating Point or On/Off control
800-543-9038 USA
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
190
GMB24-3-T N4
NEMA 4 , On/Off, Floating Point Control, Non-Spring Return, Direct Coupled, 24 VAC
Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft.
Application
For on/off and floating point control of dampers in HVAC systems. Actuator
sizing should be done in accordance with the damper manufacturer’s
specifications.
The actuator is mounted directly to a damper shaft up to 1.05" in diameter by
means of its universal clamp.
Operation
The actuator is not provided with and does not require any limit switches, but
is electronically protected against overload. The anti-rotation strap supplied
with the actuator will prevent lateral movement.
The GMB24-3-T N4 provides 95° of rotation and a visual indicator indicates
position of the actuator. When reaching the damper or actuator end position,
the actuator automatically stops. The gears can be manually disengaged with a
button on the actuator after the cover is removed.
Overload protection
Control
Input impedance
Angle of rotation
Torque
Direction of rotation
Position indication
Running time
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency listings†
Noise level
Servicing
Quality standard
Weight
reversible with
switch
dial
150 seconds
constant independent of load
5 to 100% RH (UL Type 4)
-22°F to 122°F [-30°C to 50°C]
-40°F to 176°F [-40°C to 80°C]
UL Type 4, NEMA 4, IP66
polycarbonate
cULus acc. to UL 60730-1A/-2-14,
CAN/CSA E60730-1, CSA C22.2 No. 24-93,
CE acc. to 89/336/EEC
<45dB(A)
maintenance free
ISO 9001
4.8 lbs [4.45 kg]
Add-on auxiliary switches or feedback potentiometers are easily fastened
directly onto the actuator body for signaling and switching functions.
Dimensions (mm [inches])
172 [6.77]
†Rated Impulse Voltage 4kV, Type of action 1, Control Pollution Degree 3.
800-543-9038 USA
191
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
Power consumption
Transformer sizing
Electrical connection
GMB24-3-T N4
24 VAC ±20%, 50/60 Hz
24 VDC ±10%, 50/60 Hz
4.0 W (2.0 W)
6 VA (Class 2 power source)
screw terminal (for 26 to 14 GA wire)
½” conduit connector
electronic throughout 0 to 95° rotation
on/off, floating point
600 Ω
max. 95°, adjustable with mechanical stop
360 in-lb [40 Nm]
D312
Technical Data
Power supply
The GMB24-3-T N4 actuator uses a sensorless brushless DC motor, which
is controlled by an Application Specific Integrated Circuit (ASIC). The ASIC
monitors and controls the actuator’s rotation and provides a digital rotation
sensing (DRS) function to prevent damage to the actuator in a stall condition.
Power consumption is reduced in holding mode.
GMB24-3-T N4
NEMA 4 , On/Off, Floating Point Control, Non-Spring Return, Direct Coupled, 24 VAC
Wiring Diagrams
Accessories
S1A, S2A
P…A
43442-00001
11097-00001
Auxiliary Switch (es)
Feedback Potentiometers
Gland*
Gasket for Gland*
1
Provide overload protection and disconnect as required.
NOTE: When using GMB24-3-T N4 actuators, only use accessories listed on this page.
* Both parts are needed when using an auxiliary switch or potentiometer with GMB24-3-T N4
Meets cULus or UL and CSA requirements without the need of an
electrical ground connection.
Typical Specification
WARNING
G Live Electrical Components!
During installation, testing, servicing and troubleshooting of this product, it
may be necessary to work with live electrical components. Have a qualified
licensed electrician or other individual who has been properly trained in
handling live electrical components perform these tasks. Failure to follow all
electrical safety precautions when exposed to live electrical components could
result in death or serious injury.
On/Off, Floating Point control damper actuators shall be electronic directcoupled type, which require no crank arm and linkage and be capable of direct
mounting to a shaft up to 1.05” diameter. Actuators shall have brushless DC
motor technology and be protected from overload at all angles of rotation.
Actuators shall have reversing switch and manual override on the cover of the
actuator. Run time shall be constant and independent of torque. Actuators shall
be cULus listed, have a 5-year warranty, and be manufactured under ISO 9001
International Quality Control Standards. Actuators shall be as manufactured by
Belimo.
AMB24-3-T N4
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
On/Off control
AMB24-3-T N4
Floating Point or On/Off control
800-543-9038 USA
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
192
GMX120-3
On/Off, Floating Point, Non-Spring Return, 100 to 240 VAC
Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft.
Application
For on/off and floating point control of dampers in HVAC systems. Actuator sizing
should be done in accordance with the damper manufacturer’s specifications.
The actuator is mounted directly to a damper shaft up to 1.05” in diameter by means
of its universal clamp. A crank arm and several mounting brackets are available for
applications where the actuator cannot be direct coupled to the damper shaft.
Operation
The actuator is not provided with and does not require any limit switches, but is
electronically protected against overload. The anti-rotation strap supplied with the
actuator will prevent lateral movement.
The GMX series provides 95° of rotation and a visual indicator indicates position of the
actuator. When reaching the damper or actuator end position, the actuator
automatically stops. The gears can be manually disengaged with a button on the
actuator cover.
Overload protection
Control
Input impedance
Angle of rotation
Torque
Direction of rotation
Position indication
Manual override
Running time
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency listings†
Noise level
Servicing
Quality standard
Weight
Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto
the actuator body for signaling and switching functions.
Dimensions (Inches [mm])
1/2” to 1.05” [12.7 to 26.67]
2/5” to 1.05” [10 to 26.67]
5.37” [136.4]
To center of
mounting slot.
7.02” [178.4]
1.42”
[36]
5.6” [142.4]
2” [50.8]
†Rated Impulse Voltage 2.5kV, Type of action 1, Control Pollution Degree 3.
800-543-9038 USA
193
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
Power consumption
Transformer sizing
Electrical connection
D123
100 to 240 VAC, 50/60 Hz (nominal)
85 to 265 VAC, 50/60 Hz (tolerance)
4 W (2 W)
7 VA (Class 2 power source)
18 GA appliance rated cable
1/2” conduit connector
protected NEMA 2 (IP54)
3 ft [1m] 10 ft [3m] 16 ft [5m]
electronic throughout 0 to 95° rotation
on/off, floating point
600 Ω
max. 95°, adjustable with mechanical stop
360 in-lb [40 Nm]
reversible with
switch
reflective visual indicator (snap-on)
external push button
150 seconds, constant independent of load
5 to 95% RH non condensing (EN 60730-1)
-22°F to 122°F [-30°C to 50°C]
-40°F to 176°F [-40°C to 80°C]
NEMA 2, IP54, UL enclosure type 2
UL94-5VA
cULus acc. to UL 60730-1A/-2-14,
CAN/CSA E60730-1:02,
CE acc. to 2004/108/EEC and 2006/95/EC
<45dB(A)
maintenance free
ISO 9001
3.4 lbs [1.55 kg]
2.9” [72.9]
GMX120-3
Power supply
4.55” [115.6]
Technical Data
The GMX120-3 actuators use a sensorless brushless DC motor, which is controlled by
an Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the
actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent
damage to the actuator in a stall condition. Power consumption is reduced in holding
mode.
GMX120-3
On/Off, Floating Point, Non-Spring Return, 100 to 240 VAC
Accessories
Wiring Diagrams
1/2”-1.05 [12.7 to 26.67 mm] Shaft Clamp
Multiple Actuator Mounting Bracket
GM to GM Retrofit Mounting Bracket
Crank arm Adaptor Kit
Jackshaft Adaptors for Hollow Jackshafts
Weather Shield - Steel
Weather Shield - Polycarbonate
Explosion Proof Housing
NEMA 4X Housing
13 mm Wrench
Auxiliary Switch (es)
Shaft Mount Auxiliary Switch
Feedback Potentiometers
1
Provide overload protection and disconnect as required.
2
CAUTION Equipment Damage!
Actuators may be connected in parallel.
Power consumption and input impedance must be observed.
Meets cULus requirements without the need of an electrical ground connection.
WARNING
G Live Electrical Components!
NOTE: When using GMX120-3 actuators, only use accessories listed on this page.
Typical Specification
Floating point, on/off control damper actuators shall be electronic direct-coupled type,
which require no crank arm and linkage and be capable of direct mounting to a shaft
up to 1.05” diameter. Actuators shall have brushless DC motor technology and be
protected from overload at all angles of rotation. Actuators shall have reversing switch
and manual override on the cover. Run time shall be constant and independent of
torque. Actuators shall be cULus listed, have a 5-year warranty, and be manufactured
under ISO 9001 International Quality Control Standards. Actuators shall be as
manufactured by Belimo.
During installation, testing, servicing and troubleshooting of this product, it may be
necessary to work with live electrical components. Have a qualified licensed electrician or other
individual who has been properly trained in handling live electrical components perform these
tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury.
W375_08
K-GM20
ZG-102
Z-GMA
ZG-GMA
ZG-JSA (-1, 2, 3)
ZS-100
ZS-150
ZS-260
ZS-300 (-1) (-5)
Tool-07
S1A, S2A
P370
P…A
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
W376_08
On/Off control
Floating Point or On/Off control
800-543-9038 USA
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
194
GMB(X)24-SR
Proportional, Non-Spring Return, 24 V, for 2 to 10 VDC or 4 to 20 mA
T
Torque
min.
i 360 in-lb
i lb for
f controll off damper
d
surfaces
f
up to 90 sq ft.
f
Application
For proportional modulation of dampers in HVAC systems. Actuator sizing should be
done in accordance with the damper manufacturer’s specifications.
The actuator is mounted directly to a damper shaft up to 1.05” in diameter by means
of its universal clamp. A crank arm and several mounting brackets are available for
applications where the actuator cannot be direct coupled to the damper shaft.
The actuator operates in response to a 2 to 10 VDC, or with the addition of a
500 Ω resistor, a 4 to 20 mA control input from an electronic controller or positioner.
A 2 to 10 VDC feedback signal is provided for position indication or master-slave
applications.
Operation
The actuator is not provided with and does not require any limit switches, but is
electronically protected against overload. The anti-rotation strap supplied with the
actuator will prevent lateral movement.
Overload protection
Operating range Y
Input impedance
Feedback Output U
Angle of Rotation
Torque
Direction of Rotation
Position indication
Manual override
Running time
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency listings†
Noise level
Servicing
Quality standard
Weight
The GMB(X)24-SR… actuators use a sensorless brushless DC motor, which is
controlled by an Application Specific Integrated Circuit (ASIC). The ASIC monitors and
controls the actuator’s rotation and provides a digital rotation sensing (DRS) function to
prevent damage to the actuator in a stall condition. Power consumption is reduced in
holding mode.
Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto
the actuator body for signaling and switching functions.
Dimensions (Inches [mm])
1/2” to 1.05” [12.7 to 26.67]
2/5” to 1.05” [10 to 26.67]
5.37” [136.4]
To center of
mounting slot.
7.02” [178.4]
1.42”
[36]
5.6” [142.4]
2” [50.8]
†Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3.
800-543-9038 USA
195
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
Power consumption
Transformer sizing
Electrical connection
D123
24 VAC ± 20% 50/60 Hz
24 VDC ± 10%
4.5 W (2W)
6.5 VA (Class 2 power source)
18 GA plenum rated cable
1/2” conduit connector
protected NEMA 2 (IP54)
3 ft [1m] 10 ft [3m] 16 ft [5m]
electronic throughout 0 to 95° rotation
2 to 10 VDC, 4 to 20 mA
100 kΩ (0.1 mA), 500Ω
2 to 10 VDC (max 0.5 mA)
max. 95°, adjustable with mechanical stop
360 in-lb [40 Nm]
reversible with
switch
actuator will move:
=CCW with decreasing control signal (10 to 2V)
=CW with decreasing control signal (10 to 2V)
reflective visual indicator (snap-on)
external push button
150 seconds, constant independent of load
5 to 95% RH non condensing (EN 60730-1)
-22°F to 122°F [-30°C to 50°C]
-40°F to 176°F [-40°C to 80°C]
NEMA 2, IP54, UL enclosure type 2
UL94-5VA
cULus acc. to UL 60730-1A/-2-14,
CAN/CSA E60730-1:02,
CE acc. to 2004/108/EEC and 2006/95/EC
<45dB(A)
maintenance free
ISO 9001
3.4 lbs [1.55 kg]
2.9” [72.9]
GMB(X)24-SR
Power supply
4.55” [115.6]
Technical Data
The GMB(X) series provides 95° of rotation and a visual indicator indicates position of
the actuator. When reaching the damper or actuator end position, the actuator
automatically stops. The gears can be manually disengaged with a button on the
actuator cover.
GMB(X)24-SR
Proportional, Non-Spring Return, 24 V, for 2 to 10 VDC or 4 to 20 mA
Accessories
Wiring Diagrams
1/2”-1.05 [12.7 to 26.67 mm] Shaft Clamp
Multiple Actuator Mounting Bracket
GM to GM Retrofit Mounting Bracket
Crank arm Adaptor Kit
Jackshaft Adaptors for Hollow Jackshafts
Weather Shield - Steel
Weather Shield - Polycarbonate
Explosion Proof Housing
NEMA 4X Housing
13 mm Wrench
Actuator Power Supply Simulator
Auxiliary Switch (es)
Shaft Mount Auxiliary Switch
Feedback Potentiometers
Min positioners in NEMA 4 housing
Min positioners for flush panel mounting
Pulse Width Modulation Interface
Input Rescaling Module
Analog to Digital Switch
Resistor for 4 to 20 mA Conversion
Battery Back-Up Module
Transformer
1
Provide overload protection and disconnect as required.
2
CAUTION Equipment Damage!
3
Actuators may also be powered by 24 VDC.
5
Only connect common to neg. (–) leg of control circuits.
Actuators may be connected in parallel.
Power consumption and input impedance must be observed.
Meets UL requirements without the need of an electrical ground
connection.
The ZG-R01 500 Ω resistor converts the 4 to 20 mA control signal to
2 to 10 VDC, up to 2 actuators may be connected in parallel.
WARNING
G Live Electrical Components!
During installation, testing, servicing and troubleshooting of this product, it may be
necessary to work with live electrical components. Have a qualified licensed electrician or other
individual who has been properly trained in handling live electrical components perform these
tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury.
NOTE: When using GMB(X)24-SR… actuators, only use accessories listed on this page.
W253_08
K-GM20
ZG-102
Z-GMA
ZG-GMA
ZG-JSA (-1, 2, 3)
ZS-100
ZS-150
ZS-260
ZS-300 (-1) (-5)
Tool-07
PS-100
S1A, S2A
P370
P…A
SGA24
SGF24
PTA-250
IRM-100
ADS-100
ZG-R01
NSV24 US
ZG-X40
Proportional control damper actuators shall be electronic direct-coupled type, which
require no crank arm and linkage and be capable of direct mounting to a shaft up to
1.05” diameter. Actuators must provide proportional damper control in response to a 2
to 10 VDC or, with the addition of a 500 Ω resistor, a 4 to 20 mA control input from an
electronic controller or positioner. Actuators shall have Brushless DC motor technology
and be protected from overload at all angles of rotation. Actuators shall have reversing
switch and manual override on the cover. Run time shall be constant and independent
of torque. A 2 to 10 VDC feedback signal shall be provided for position indication.
Actuators shall be cULus listed, have a 5-year warranty, and be manufactured under
ISO 9001 International Quality Control Standards. Actuators shall be as manufactured
by Belimo.
2 to 10 VDC control
W253_08
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
Typical Specification
4 to 20 mA control
800-543-9038 USA
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
196
GMB24-SR-T N4
NEMA 4, Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 mA
Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft.
Application
For proportional modulation of dampers in HVAC systems. Actuator sizing
should be done in accordance with the damper manufacturer’s specifications.
The actuator is mounted directly to a damper shaft up to 1.05" in diameter by
means of its universal clamp.
The actuator operates in response to a 2 to 10 VDC, or with the addition of a
500 Ω resistor, a 4 to 20 mA control input from an electronic controller or
positioner. A 2 to 10 VDC feedback signal is provided for position indication or
master-slave applications.
Operation
The actuator is not provided with and does not require any limit switches, but
is electronically protected against overload. The anti-rotation strap supplied
with the actuator will prevent lateral movement.
Overload protection
Operating range Y
Input impedance
Angle of rotation
Torque
Direction of rotation
Position indication
Running time
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency listings†
Noise level
Servicing
Quality standard
Weight
switch
reversible with
dial
150 seconds
constant independent of load
5 to 100% RH (UL Type 4)
-22°F to 122°F [-30°C to 50°C]
-40°F to 176°F [-40°C to 80°C]
UL Type 4X, NEMA 4X, IP66
polycarbonate
cULus acc. to UL 60730-1A/-2-14,
CAN/CSA E60730-1, CSA C22.2 No. 24-93,
CE acc. to 89/336/EEC
<45dB(A)
maintenance free
ISO 9001
9.8 lbs [4.45 kg]
The GMB24-SR-T N4 actuator uses a sensorless brushless DC motor, which
is controlled by an Application Specific Integrated Circuit (ASIC). The ASIC
monitors and controls the actuator’s rotation and provides a digital rotation
sensing (DRS) function to prevent damage to the actuator in a stall condition.
Power consumption is reduced in holding mode.
Add-on auxiliary switches or feedback potentiometers are easily fastened
directly onto the actuator body for signaling and switching functions.
Dimensions (inches [mm])
172 [6.77]
†Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3.
800-543-9038 USA
197
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
Power consumption
Transformer Sizing
Electrical connection
GMB24-SR-T N4
24 VAC ± 20% 50/60 Hz
24 VDC ± 10%
4.5 W (2.0 W)
6.5 VA (Class 2 power source)
screw terminal (for 26 to 14 GA wire)
½” conduit connector
electronic throughout 0 to 95° rotation
2 to 10 VDC, 4 to 20 mA
100 kΩ (0.1 mA), 500 Ω
max. 95°, adjustable with mechanical stop
360 in-lb [40 Nm]
D312
Technical Data
Power supply
The GMB24-SR-T N4 provides 95° of rotation and a visual indicator indicates
position of the actuator. When reaching the damper or actuator end position,
the actuator automatically stops. The gears can be manually disengaged with a
button on the actuator after the cover is removed.
GMB24-SR-T N4
NEMA 4, Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 mA
Wiring Diagrams
Accessories
S1A, S2A
P…A
SGA24
SGF24
PTA-250
IRM-100
ADS-100
ZG-R01
NSV24 US
ZG-X40
43442-00001
11097-00001
Auxiliary Switch (es)
Feedback Potentiometers
Min positioners for surface mounting
Min positioners for flush panel mounting
Pulse Width Modulation Interface
Input Rescaling Module
Analog to Digital Switch
Resistor for 4 to 20 mA Conversion
Battery Back-Up Module
Transformer
Gland*
Gasket for Gland*
1
Provide overload protection and disconnect as required.
2
CAUTION
N Equipment Damage!
3
Actuators may also be powered by 24 VDC.
5
Only connect common to neg. (–) leg of control circuits
NOTE: When using GMB24-SR-T N4 actuators, only use accessories listed on this page.
* Both parts are needed when using an auxiliary switch or potentiometer with GMB24-SR-T N4
Actuators may be connected in parallel.
Power consumption and input impedance must be observed.
The ZG-R01 500 Ω resistor converts the 4 to 20 mA control signal to 2
to 10 VDC, up to 2 actuators may be connected in parallel.
WARNING
G Live Electrical Components!
During installation, testing, servicing and troubleshooting of this product, it
may be necessary to work with live electrical components. Have a qualified
licensed electrician or other individual who has been properly trained in
handling live electrical components perform these tasks. Failure to follow all
electrical safety precautions when exposed to live electrical components could
result in death or serious injury.
Typical Specification
Proportional control damper actuators shall be electronic direct-coupled type,
which require no crank arm and linkage and be capable of direct mounting
to a shaft up to 1.05” diameter. Actuators must provide proportional damper
control in response to a 2 to 10 VDC or, with the addition of a 500 Ω resistor,
a 4 to 20 mA control input from an electronic controller or positioner.
Actuators shall have brushless DC motor technology and be protected from
overload at all angles of rotation. Actuators shall have reversing switch and
manual override on the cover of the actuator. Run time shall be constant and
independent of torque. A 2 to 10 VDC feedback signal shall be provided for
position indication. Actuators shall be cULus listed, NEMA 4X, have a 5-year
warranty, and be manufactured under ISO 9001 International Quality Control
Standards. Actuators shall be as manufactured by Belimo.
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
AMB24-SR-T N4
2 to 10 VDC control
AMB24-SR-T N4
4 to 20 mA control
800-543-9038 USA
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
198
GMB(X)24-MFT
Proportional, Non-Spring Return, 24 V, Multi-Function Technology®
T
Torque
min.
i 360 in-lb
i lb for
f controll off damper
d
surfaces
f
up to 90 sq ft.
f
Application
For proportional modulation of dampers in HVAC systems. Actuator sizing should be
done in accordance with the damper manufacturer’s specifications.
The actuator is mounted directly to a damper shaft up to 1.05” in diameter by means
of its universal clamp. A crank arm and several mounting brackets are available for
applications where the actuator cannot be direct coupled to the damper shaft.
The default parameters for 2 to 10 VDC applications of the …MFT actuator are
assigned during manufacturing. If necessary, custom versions of the actuators can be
ordered. The parameters can be changed by two means: pre-set and custom
configurations from Belimo or on-site configurations using the Belimo PC-Tool
software.
Operation
The actuator is not provided with and does not require any limit switches, but is
electronically protected against overload. The anti-rotation strap supplied with the
actuator will prevent lateral movement.
Power consumption
Transformer sizing
Electrical connection
Overload protection
Operating range Y
Input impedance
Feedback output U
Angle of rotation
Torque
Direction of rotation
Position indication
Manual override
Running time
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency listings†
Noise level
Servicing
Quality standard
Weight
The GMB(X)24-MFT actuators use a brushless DC motor, which is controlled by an
Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the
actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent
damage to the actuator in a stall condition. Power consumption is reduced in holding
mode.
Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto
the actuator body for signaling and switching functions.
Dimensions (Inches [mm])
1/2” to 1.05” [12.7 to 26.67]
2/5” to 1.05” [10 to 26.67]
5.37” [136.4]
To center of
mounting slot.
7.02” [178.4]
1.42”
[36]
5.6” [142.4]
2” [50.8]
†Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3.
800-543-9038 USA
199
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
24 VAC ± 20% 50/60 Hz
24 VDC ± 10%
4.5 W (1.5 W)
7 VA (Class 2 power source)
18 GA plenum rated cable
1/2” conduit connector
protected NEMA 2 (IP54)
3 ft [1m] 10 ft [3m] 16 ft [5m]
electronic throughout 0 to 95° rotation
2 to 10 VDC, 4 to 20 mA (default)
variable (VDC, PWM, floating point, on/off)
100 kΩ (0.1 mA), 500 Ω
1500 Ω (PWM, floating point, on/off)
2 to 10 VDC, 0.5 mA max
VDC variable
max. 95°, adjustable with mechanical stop
electronically variable
360 in-lb [40 Nm]
reversible with
switch
reflective visual indicator (snap-on)
external push button
150 seconds (default)
variable (75 to 300 seconds)
5 to 95% RH non condensing (EN 60730-1)
-22°F to +122°F [-30°C to +50°C]
-40°F to +176°F [-40°C to +80°C]
NEMA 2, IP54, UL enclosure type 2
UL94-5VA
cULus acc. to UL 60730-1A/-2-14,
CAN/CSA E60730-1:02,
CE acc. to 2004/108/EEC and 2006/95/EC
<45dB(A)
maintenance free
ISO 9001
3.4 lbs [1.55 kg]
D123
Power supply
The GMB(X) series provides 95° of rotation and a visual indicator indicates position of
the actuator. When reaching the damper or actuator end position, the actuator
automatically stops. The gears can be manually disengaged with a button on the
actuator cover.
2.9” [72.9]
GMB(X)24-MFT
4.55” [115.6]
Technical Data
GMB(X)24-MFT
Proportional, Non-Spring Return, 24 V, Multi-Function Technology®
Accessories
WARNING
G Live Electrical Components!
3/4" [20 mm] Shaft Clamp
Multiple Actuator Mounting Bracket
Crank arm Adaptor Kit
Jackshaft Adaptors for Hollow Jackshafts
Weather Shield - Steel
Weather Shield - Polycarbonate
Explosion Proof Housing
NEMA 4X Housing
13 mm Wrench
Actuator Power Supply Simulator
Auxiliary Switch (es)
Shaft Mount Auxiliary Switch
Feedback Potentiometers
Min positioners in NEMA 4 housing
Min positioners for flush panel mounting
Analog to Digital Switch
Resistor for 4 to 20 mA Conversion
Battery Back-Up Module
Transformer
During installation, testing, servicing and troubleshooting of this product, it may be
necessary to work with live electrical components. Have a qualified licensed electrician or other
individual who has been properly trained in handling live electrical components perform these
tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury.
W399_08
K-GM20
ZG-102
ZG-GMA
ZG-JSA (-1, 2, 3)
ZS-100
ZS-150
ZS-260
ZS-300 (-1) (-5)
Tool-07
PS-100
S1A, S2A
P370
P…A
SGA24
SGF24
ADS-100
ZG-R01
NSV24 US
ZG-X40
NOTE: When using GMB(X)24-MFT actuators, only use accessories listed on this page.
W399_08
VDC/4-20 mA
Typical Specification
Proportional control damper actuators shall be electronic direct-coupled type, which
require no crank arm and linkage and be capable of direct mounting to a shaft up to
1.05” diameter. Actuators must provide proportional damper control in response to a 2
to 10 VDC or, with the addition of a 500 Ω resistor, a 4 to 20 mA control input from an
electronic controller or positioner. Actuators shall have brushless DC motor technology
and be protected from overload at all angles of rotation. Actuators shall have reversing
switch and manual override on the cover. Run time shall be constant and independent
of torque. Actuators shall be cULus listed, have a 5-year warranty, and be
manufactured under ISO 9001 International Quality Control Standards. Actuators shall
be as manufactured by Belimo.
W399_08
PWM
M
1
2
3
4
5
8
9
Provide overload protection and disconnect as required.
CAUTION Equipment Damage!
Actuators may be connected in parallel if not mechanically mounted to the same
shaft. Power consumption and input impedance must be observed.
Actuators may also be powered by 24 VDC.
Position feedback cannot be used with Triac sink controller.
The actuator internal common reference is not compatible.
Control signal may be pulsed from either the Hot (source)
or the Common (sink) 24 VAC line.
Contact closures A & B also can be triacs.
A & B should both be closed for triac source and open for triac sink.
For triac sink the common connection from the actuator
must be connected to the hot connection of the controller.
On/Off
Off controll
W399_08
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
Wiring Diagrams
Meets UL requirements without the need of an electrical ground
connection.
The ZG-R01 500 Ω resistor may be used.
Floating Point control
800-543-9038 USA
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
200
GMX24-MFT-T N4
NEMA 4, Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology®
Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft.
Application
For proportional modulation of dampers in HVAC systems. Actuator sizing
should be done in accordance with the damper manufacturer’s specifications.
The actuator is mounted directly to a damper shaft up to 1.05" in diameter by
means of its universal clamp.
The default parameters for 2 to 10 VDC applications of the …MFT actuator are
assigned during manufacturing. If necessary, custom versions of the actuators
can be ordered. The parameters can be changed by two means: pre-set and
custom configurations from Belimo or on-site configurations using the Belimo
PC-Tool software.
Operation
The actuator is not provided with and does not require any limit switches, but
is electronically protected against overload. The anti-rotation strap supplied
with the actuator will prevent lateral movement.
The GMX24-MFT-T N4 provides 95° of rotation and a visual indicator indicates
position of the actuator. When reaching the damper or actuator end position,
the actuator automatically stops. The gears can be manually disengaged with a
button on the actuator after the cover is removed.
Input impedance
Feedback output U
Angle of rotation
Torque
Direction of rotation
Position indication
Running time
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency listings†
Noise level
Servicing
Quality standard
Weight
Add-on auxiliary switches or feedback potentiometers are easily fastened
directly onto the actuator body for signaling and switching functions.
Dimensions (inches [mm])
reversible with
switch
dial
150 seconds (default)
variable (45 to 170 seconds)
5 to 100% RH (UL Type 4)
-22°F to 122°F [-30°C to 50°C]
-40°F to 176°F [-40°C to 80°C]
UL Type 4X, NEMA 4X, IP66
polycarbonate
cULus acc. to UL 60730-1A/-2-14,
CAN/CSA E60730-1, CSA C22.2 No. 24-93,
CE acc. to 89/336/EEC
<45dB(A)
maintenance free
ISO 9001
10 lbs [4.56 kg]
†Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3.
800-543-9038 USA
201
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
Overload protection
Operating range Y
The GMX24-MFT-T N actuators use a brushless DC motor, which is controlled
by an Application Specific Integrated Circuit (ASIC). The ASIC monitors
and controls the actuator’s rotation and provides a digital rotation sensing
(DRS) function to prevent damage to the actuator in a stall condition.Power
consumption is reduced in holding mode.
D312
Power consumption
Transformer sizing
Electrical connection
GMX24-MFT-T N4
24 VAC ± 20% 50/60 Hz
24 VDC ± 10%
4.0 W (2.0 W)
7 VA (Class 2 power source)
screw terminal (for 26 to 14 GA wire)
½” conduit connector
electronic throughout 0 to 95° rotation
2 to 10 VDC, 4 to 20 mA (default)
variable (VDC, floating point, on/off)
100 kΩ (0.1 mA), 500 Ω
1500 Ω (PWM, floating point, on/off)
2 to 10 VDC, 0.5 mA max, VDC variable
max. 95°, adjustable with mechanical stop
electronically variable
360 in-lb [40 Nm]
172 [6.77]
Technical Data
Power supply
GMX24-MFT-T N4
Accessories
S1A, S2A
P…A
SGA24
SGF24
ADS-100
ZG-R01
NSV24 US
ZG-X40
43442-00001
11097-00001
W399_08
NEMA 4, Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology®
Auxiliary Switch (es)
Feedback Potentiometers
Min positioners for surface mounting
Min positioners for flush panel mounting
Analog to Digital Switch
Resistor for 4 to 20 mA Conversion
Battery Back-Up Module
Transformer
Gland*
Gasket for Gland*
NOTE: When using GMX24-MFT-T N4 actuators, only use accessories listed on this page.
* Both parts are needed when using an auxiliary switch or potentiometer with GMX24-MFT-T N4
W399_08
VDC/4-20 mA
Typical Specification
PWM
M
W399_08
Proportional control damper actuators shall be electronic direct-coupled type,
which require no crank arm and linkage and be capable of direct mounting
to a shaft up to 1.05” diameter. Actuators must provide proportional damper
control in response to a 2 to 10 VDC or, with the addition of a 500 Ω resistor,
a 4 to 20 mA control input from an electronic controller or positioner.
Actuators shall have brushless DC motor technology and be protected from
overload at all angles of rotation. Actuators shall have reversing switch and
manual override on the cover of the actuator. Run time shall be constant and
independent of torque. Actuators shall be cULus listed, have a 5-year warranty,
and be manufactured under ISO 9001 International Quality Control Standards.
Actuators shall be as manufactured by Belimo.
1
Provide overload protection and disconnect as required.
2
CAUTION
N Equipment Damage!
3
4
5
8
9
Actuators may be connected in parallel if not mechanically mounted
to the same shaft. Power consumption and input impedance must be
observed.
On/Off control
W399_08
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
Wiring Diagrams
Actuators may also be powered by 24 VDC.
Position feedback cannot be used with Triac sink controller.
The actuator internal common reference is not compatible.
Control signal may be pulsed from either the Hot (source)
or the Common (sink) 24 VAC line.
Contact closures A & B also can be triacs.
A & B should both be closed for triac source and open for triac sink.
For triac sink the common connection from the actuator
must be connected to the hot connection of the controller.
The ZG-R01 500 Ω resistor may be used.
Floating Point control
WARNING
G Live Electrical Components!
During installation, testing, servicing and troubleshooting of this product, it
may be necessary to work with live electrical components. Have a qualified
licensed electrician or other individual who has been properly trained in
handling live electrical components perform these tasks. Failure to follow all
electrical safety precautions when exposed to live electrical components could
result in death or serious injury.
800-543-9038 USA
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
202
GMX24-MFT95
Proportional, Non-Spring Return, 24 V, 0 to 135 Ω Input
T
Torque
min.
i 360 in-lb
i lb for
f controll off damper
d
surfaces
f
up to 90 sq ft.
f
Application
For proportional modulation of dampers in HVAC systems. Actuator sizing should be
done in accordance with the damper manufacturer’s specifications.
The actuator is mounted directly to a damper shaft up to 1.05” in diameter by means
of its universal clamp. A crank arm and several mounting brackets are available for
applications where the actuator cannot be direct coupled to the damper shaft.
The default parameters for 0 to 135Ω input applications of the …MFT95 actuator are
assigned during manufacturing. If necessary, custom versions of the actuators can be
ordered. The parameters can be changed by two means: pre-set and custom
configurations from Belimo or on-site configurations using the Belimo PC-Tool
software.
Operation
The actuator is not provided with and does not require any limit switches, but is
electronically protected against overload. The anti-rotation strap supplied with the
actuator will prevent lateral movement.
Power consumption
Transformer sizing
Electrical connection
Overload protection
Operating range WRB
Feedback output U
Angle of rotation
Torque
Direction of rotation
Position indication
Manual override
Running time
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency listings†
Noise level
Servicing
Quality standard
Weight
The GMX24-MFT95 actuators use a brushless DC motor, which is controlled by an
Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the
actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent
damage to the actuator in a stall condition. Power consumption is reduced in holding
mode.
Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto
the actuator body for signaling and switching functions.
Dimensions (Inches [mm])
1/2” to 1.05” [12.7 to 26.67]
2/5” to 1.05” [10 to 26.67]
5.37” [136.4]
To center of
mounting slot.
7.02” [178.4]
1.42”
[36]
5.6” [142.4]
2” [50.8]
†Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3.
800-543-9038 USA
203
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
24 VAC ± 20% 50/60 Hz
24 VDC ± 10%
4.5 W (1.5 W)
7 VA (Class 2 power source)
18 GA plenum rated cable
1/2” conduit connector
protected NEMA 2 (IP54)
3 ft [1m]
electronic throughout 0 to 95° rotation
135 Ω Honeywell Electronic Series 90,
0 to 135 Ω input
2 to 10 VDC, 0.5 mA max
VDC variable
max. 95°, adjustable with mechanical stop
electronically variable
360 in-lb [40 Nm]
reversible with
switch
reflective visual indicator (snap-on)
external push button
150 seconds (default)
variable (100 to 280 seconds)
5 to 95% RH non condensing (EN 60730-1)
-22°F to 122°F [-30°C to 50°C]
-40°F to 176°F [-40°C to 80°C]
NEMA 2, IP54, UL enclosure type 2
UL94-5VA
cULus acc. to UL 60730-1A/-2-14,
CAN/CSA E60730-1:02,
CE acc. to 2004/108/EEC and 2006/95/EC
<45dB(A)
maintenance free
ISO 9001
3.4 lbs [1.55 kg]
D123
Power supply
The GMX series provides 95° of rotation and a visual indicator indicates position of the
actuator. When reaching the damper or actuator end position, the actuator
automatically stops. The gears can be manually disengaged with a button on the
actuator cover.
2.9” [72.9]
GMX24-MFT95
4.55” [115.6]
Technical Data
GMX24-MFT95
Proportional, Non-Spring Return, 24 V, 0 to 135 Ω Input
Accessories
K-GM20
ZG-102
ZG-GMA
ZG-JSA (-1, 2, 3)
ZS-100
ZS-150
ZS-260
ZS-300 (-1) (-5)
Tool-07
PS-100
S1A, S2A
P370
P…A
NSV24 US
ZG-X40
Wiring Diagrams
1/2”-1.05 [12.7 to 26.67 mm] Shaft Clamp
Multiple Actuator Mounting Bracket
Crank arm Adaptor Kit
Jackshaft Adaptors for Hollow Jackshafts
Weather Shield - Steel
Weather Shield - Polycarbonate
Explosion Proof Housing
NEMA 4X Housing
13 mm Wrench
Actuator Power Supply Simulator
Auxiliary Switch (es)
Shaft Mount Auxiliary Switch
Feedback Potentiometers
Battery Back-Up Module
Transformer
5
Actuators with plenum rated cable do not have numbers on wires; use
color codes instead. Actuators with appliance cables are numbered.
21
Provide overload protection and disconnect as required.
222
Actuators and controller must have separate transformers.
233
Consult controller instruction data for more detailed information.
244
Resistor value depends on the type of controller and the number of
actuators. No resistor is used for one actuator. Honeywell® resistor kits
may also be used.
255
To reverse control rotation, use the reversing switch.
Typical Specification
24 VAC Transformer
21
Proportional control damper actuators shall be electronic direct-coupled type, which
require no crank arm and linkage and be capable of direct mounting to a shaft up to
1.05” diameter. Actuators must provide proportional damper control in response to 0
to 135 Ω input from an electronic controller or positioner. Actuators shall have
brushless DC motor technology and be protected from overload at all angles of
rotation. Actuators shall have reversing switch and manual override on the cover. Run
time shall be constant and independent of torque. Actuators shall be cULus listed,
have a 5-year warranty, and be manufactured under ISO 9001 International Quality
Control Standards. Actuators shall be as manufactured by Belimo.
S963A
Minimum Position
Potentiometer
Line
5
Blk (1) Common
Volts
Red (2) + Hot
25
Series 90
Controller
B
R
R
22
B
W
Pnk (4)
Wht (3)
Gry (5)
Org (6)
W
Shunting
Resistor
Wnew60408_6
NOTE: When using GMX24-MFT95 actuators, only use accessories listed on this page.
23
24
W
R
B
‘U5’ Output 2 to 10 VDC
-MFT95
B
R
W
H205 Change- Occupied
over Controller Contact
Wire Colors
3 = White
4 = Pink
5 = Gray
6 = Orange
21
Line
Blk (1) Common
Volts
Line
Blk (1) Common
Volts
To other
actuators
Red (2) + Hot
R
B
‘U5’ Output 2 to 10 VDC
-MFT95
B
Gry (5)
Wiring multiple actuators to a Series 90 controller
using a minimum position potentiometer.
B
24 VAC Transformer
21
Org (6) ‘U5’ Output 2 to 10 VDC
5
Line
-MFT95
21 24 VAC Transformer
Blk (1) Common
Volts
Line
W016
24
Wht (3) R
Red (2) + Hot
23
Blk (1) Common
Volts
Red (2) + Hot
22
23
Series 90
Controller
A
Line
Volts
W
Pnk (4) W
R
Wht (3) R
B
Controller
B
Wnew60408_6
Pnk (4) W
135 Ω
23
25
W
23
A
22
Pnk (4)
Wht (3)
Gry (5)
Org (6)
24
W
W
R
B
R
Wht (3) R
B
Gry (5) B
Series 90 low limit control
135 Ω for 0 to 50% control
280 Ω for 0 to 100% control
Gry (5) B
Org (6) ‘U5’ Output 2 to 10 VDC
Pnk (4) W
24
Org (6) ‘U5’ Output 2 to 10 VDC
-MFT95
Low Limit Control
-MFT95
5
24 VAC Transformer
21
Override
W017
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
Wnew60408_6
5
21 24 VAC Transformer
Red (2) + Hot
22
Wnew60408_6
1 = Black
2 = Red
Line
Blk (1) Common
Volts
Red (2) + Hot
23
22
Series 90
Controller
W
Pnk (4) W
R
Wht (3) R
B
R
W
B
24
Gry (5) B
Org (6) ‘U5’ Output 2 to 10 VDC
Series 90 high limit control - 280 Ω
-MFT95
High Limit Control
800-543-9038 USA
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
204
GMX24-PC
Proportional, Non-Spring Return, 24 V, 0 to 20 V Phasecut
T
Torque
min.
i 360 in-lb
i lb for
f controll off damper
d
surfaces
f
up to 90 sq ft.
f
Application
For proportional modulation of dampers in HVAC systems. Actuator sizing should be
done in accordance with the damper manufacturer’s specifications.
The actuator is mounted directly to a damper shaft up to 1.05” in diameter by means
of its universal clamp. A crank arm and several mounting brackets are available for
applications where the actuator cannot be direct coupled (only the positive part of the
sine wave) to the damper shaft.
The actuator operates in response to 0 to 20V phasecut control input only on the
positive part of the sine wave from an electronic controller or positioner. A 2 to 10
VDC feedback signal is provided for position indication.
Operation
The actuator is not provided with and does not require any limit switches, but is
electronically protected against overload. The anti-rotation strap supplied with the
actuator will prevent lateral movement.
Overload protection
Operating range Y
Input impedance
Feedback output U
Angle of rotation
Torque
Direction of rotation
Position indication
Manual override
Running time
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency listings†
Noise level
Servicing
Quality standard
Weight
The GMX24-PC actuators use a brushless DC motor, which is controlled by an
Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the
actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent
damage to the actuator in a stall condition. Power consumption is reduced in holding
mode.
Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto
the actuator body for signaling and switching functions.
Dimensions (Inches [mm])
1/2” to 1.05” [12.7 to 26.67]
2/5” to 1.05” [10 to 26.67]
5.37” [136.4]
To center of
mounting slot.
7.02” [178.4]
1.42”
[36]
5.6” [142.4]
2” [50.8]
†Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3.
800-543-9038 USA
205
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
Power consumption
Transformer sizing
Electrical connection
D123
24 VAC ± 20% 50/60 Hz
24 VDC ± 10%
4.5 W (1.5 W)
7 VA (Class 2 power source)
18 GA plenum rated cable
1/2” conduit connector
protected NEMA 2 (IP54)
3 ft [1m]
electronic throughout 0 to 95° rotation
0 to 20 V phasecut
control is only for the postiive part of the sine
wave (max of 10 volts)
8 kΩ (50 mW)
2 to 10 VDC, 0.5 mA max
max. 95°, adjustable with mechanical stop
electronically variable
360 in-lb [40 Nm]
reversible with
switch
reflective visual indicator (snap-on)
external push button
150 seconds (default)
5 to 95% RH non condensing (EN 60730-1)
-22°F to 122°F [-30°C to 50°C]
-40°F to 176°F [-40°C to 80°C]
NEMA 2, IP54, UL enclosure type 2
UL94-5VA
cULus acc. to UL 60730-1A/-2-14,
CAN/CSA E60730-1:02,
CE acc. to 2004/108/EEC and 2006/95/EC
<45dB(A)
maintenance free
ISO 9001
3.4 lbs [1.55 kg]
2.9” [72.9]
GMX24-PC
Power supply
4.55” [115.6]
Technical Data
The GMX series provides 95° of rotation and a visual indicator indicates position of the
actuator. When reaching the damper or actuator end position, the actuator
automatically stops. The gears can be manually disengaged with a button on the
actuator cover.
GMX24-PC
Proportional, Non-Spring Return, 24 V, 0 to 20 V Phasecut
Accessories
K-GM20
ZG-102
ZG-GMA
ZG-JSA (-1, 2, 3)
ZS-100
ZS-150
ZS-260
ZS-300 (-1) (-5)
Tool-07
PS-100
S1A, S2A
P370
P…A
NSV24 US
ZG-X40
1/2”-1.05 [12.7 to 26.67 mm] Shaft Clamp
Multiple Actuator Mounting Bracket
Crank arm Adaptor Kit
Jackshaft Adaptors for Hollow Jackshafts
Weather Shield - Steel
Weather Shield - Polycarbonate
Explosion Proof Housing
NEMA 4X Housing
13 mm Wrench
Actuator Power Supply Simulator
Auxiliary Switch (es)
Shaft Mount Auxiliary Switch
Feedback Potentiometers
Battery Back-Up Module
Transformer
Provide overload protection and disconnect as required.
1
CAUTION Equipment Damage!
2
Actuators may be connected in parallel.
Power consumption and input impedance must be observed.
Actuators may also be powered by 24 VDC.
3
Meets UL requirements without the need of an electrical ground
connection.
WARNING
G Live Electrical Components!
During installation, testing, servicing and troubleshooting of this product, it may be
necessary to work with live electrical components. Have a qualified licensed electrician or other
individual who has been properly trained in handling live electrical components perform these
tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury.
NOTE: When using GMX24-PC actuators, only use accessories listed on this page.
Proportional control damper actuators shall be electronic direct-coupled type, which
require no crank arm and linkage and be capable of direct mounting to a shaft up to
1.05” diameter. Actuators must provide proportional damper control in response to 0
to 20 V phasecut control input from an electronic controller or positioner. Actuators
shall have brushless DC motor technology and be protected from overload at all
angles of rotation. Actuators shall have reversing switch and manual override on the
cover. Run time shall be constant and independent of torque. Actuators shall be cULus
listed, have a 5-year warranty, and be manufactured under ISO 9001 International
Quality Control Standards. Actuators shall be as manufactured by Belimo.
W185
Typical Specification
1
24 VAC Transformer
Line
Volts
Blk (1) Common –
Red (2) Hot +
3
Pnk (6) Y Input, 0 to 20V phasecut
Control Signal (–)
0 to 20 V Phasecut (+)
Wiring Diagram
Org (5) U Output, 2 to 10V
…PC
2
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
Proportional Control
800-543-9038 USA
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
206
GMX24-LON
LonWorks®, Non-Spring Return, 24 V
T
Torque
min.
i 360 in-lb
i lb for
f controll off damper
d
surfaces
f
up to 90 sq ft.
f
Application
Direct coupled actuators for direct link to LonWorks network. Actuators are easily
installed by direct shaft mounting on air dampers in ventilation and air conditioning
systems. Actuator can be controlled by any compatible LON system.
For proportional modulation of dampers in HVAC systems. Actuator sizing should be
done in accordance with the damper manufacturer’s specifications.
The actuator is mounted directly to a damper shaft up to 1.05” in diameter by means
of its universal clamp. A crank arm and several mounting brackets are available for
applications where the actuator cannot be direct coupled to the damper shaft.
Operation
The actuator is not provided with and does not require any limit switches, but is
electronically protected against overload. The anti-rotation strap supplied with the
actuator will prevent lateral movement.
The GMX24-LON series provides 95° of rotation and a visual indicator indicates
position of the actuator. When reaching the damper or actuator end position, the
actuator automatically stops. The gears can be manually disengaged with a button on
the actuator cover.
Overload protection
Angle of rotation
Torque
Direction of rotation
Position indication
Manual override
Running time
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency listings†
Noise level
Servicing
Quality standard
Weight
Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto
the actuator body for signaling and switching functions.
Dimensions (Inches [mm])
1/2” to 1.05” [12.7 to 26.67]
2/5” to 1.05” [10 to 26.67]
5.37” [136.4]
To center of
mounting slot.
7.02” [178.4]
†Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3.
1.42”
[36]
LonWorks®
5.6” [142.4]
2” [50.8]
according to LonMARK® 3.3
Neuron 3120
FTT-10A, compatible with LPT-10
according to LonMARK® Damper
actuator object #8110
open loop sensor object #1
LNS plug-in for actuator/sensor can be run with any LNS based integration
tool (min. for LNS 3.x)
Service button and status LED according to LonMARK® guidelines
Conductors, cables
conductor lengths, cable specifications and
topology of the LonWorks® network according to
the Echelon® directives
Certified
Processor
Transceiver
Functional profile
LonWorks and LonMARK © 2007-2009 LonMark International
800-543-9038 USA
207
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
Power consumption
Transformer sizing
Electrical connection
The GMX24-LON actuators use a brushless DC motor, which is controlled by an
Application Specific Integrated Circuit (ASIC). The ASIC monitors and controls the
actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent
damage to the actuator in a stall condition. Power consumption is reduced in holding
mode.
D123
24 VAC ± 20% 50/60 Hz
24 VDC ± 10%
4.5 W (1.5 W)
7 VA (Class 2 power source)
18 GA plenum rated cable
1/2” conduit connector
protected NEMA 2 (IP54)
3 ft [1m]
electronic throughout 0 to 95° rotation
max. 95°, adjustable with mechanical stop
electronically variable
360 in-lb [40 Nm]
reversible with
switch
reflective visual indicator (snap-on)
external push button
150 seconds (default)
5 to 95% RH non condensing (EN 60730-1)
-22°F to +122°F [-30°C to +50°C]
-40°F to +176°F [-40°C to +80°C]
NEMA 2, IP54, UL enclosure type 2
UL94-5VA
cULus acc. to UL 60730-1A/-2-14,
CAN/CSA E60730-1:02,
CE acc. to 2004/108/EEC and 2006/95/EC
<45dB(A)
maintenance free
ISO 9001
3.4 lbs [1.55 kg]
2.9” [72.9]
GMX24-LON
Power supply
4.55” [115.6]
Technical Data
GMX24-LON
®
Accessories
T
1
2
T
~
+
–
5
6
7
LON
3
LON
+
–
MFT
3/4" [20 mm] Shaft Clamp
Multiple Actuator Mounting Bracket
Crank arm Adaptor Kit
Jackshaft Adaptors for Hollow Jackshafts
Weather Shield - Steel
Weather Shield - Polycarbonate
Explosion Proof Housing
NEMA 4X Housing
13 mm Wrench
Actuator Power Supply Simulator
Auxiliary Switch (es)
Shaft Mount Auxiliary Switch
Feedback Potentiometers
Min positioners in NEMA 4 housing
Min positioners for flush panel mounting
Analog to Digital Switch
Battery Back-Up Module
Transformer
~
Sensor scaling:
The sensors can be scaled with the sensor plug-in (sensor table).
NOTE: When using GMX24-LON actuators, only use accessories listed on this page.
Typical Specification
Sensor
Temperature range
Resistance range
Resolution
Ni1000
–28 ... +98°C
850 ... 1600 Ω
1Ω
PT1000
–35 ... +155°C
850 ... 1600 Ω
1Ω
–10 ... +160°C
(depending on type)
200 ... 60 kΩ
1Ω
NTC
–
Schema_LON_03
Connection with Passive Sensor, e.g. Pt1000, Ni1000, NTC
T
Proportional control damper actuators shall be electronic direct-coupled type, which
require no crank arm and linkage and be capable of direct mounting to a shaft up to
1.05” diameter. Actuators shall have brushless DC motor technology and be protected
from overload at all angles of rotation. Actuators shall have reversing switch and
manual override on the cover. Run time shall be constant and independent of torque.
Actuators shall be cULus listed, have a 5-year warranty, and be manufactured under
ISO 9001 International Quality Control Standards. Actuators shall be as manufactured
by Belimo.
~
K-GM20
ZG-102
ZG-GMA
ZG-JSA (-1, 2, 3)
ZS-100
ZS-150
ZS-260
ZS-300 (-1) (-5)
Tool-07
PS-100
S1A, S2A
P370
P…A
SGA24
SGF24
ADS-100
NSV24 US
ZG-X40
Schema_LON_02
LonWorks , Non-Spring Return, 24 V
+
Wiring Diagrams
2
5
6
7
T
~
6
7
LON
LON
Connection with Switching Contact, e.g. Δp-monitor
+
LON
–
LON
+
MFT
–
+
5
MFT
Schema_LON_01
3
3
Schema_LON_04
1
–
T
Connection without Sensor
T
–
+
3
5
6
7
Sensor scaling:
The sensors can be scaled with the
sensor plug-in (sensor table)
LON
2
LON
1
MFT
Possible input voltage range:
0 ... 32 V (resolution 30 mV)
~
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
V
Possible connection of a
voltmeter for checking
the position feedback U.
2
~
T
V
1
T
+
~
~
–
Requirements for
switching contact:
The switching contact must be
able to accurately switch a current of 16 mA @ 24 V.
Connection with Active Sensor, e.g. 0...10 V @ 0...50° C
800-543-9038 USA
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
208
GMX24-LON
LonWorks®, Non-Spring Return, 24 V
Functional Profile according to LonMARK
K®
The LON-capable damper actuator is certified by LonMARK®. The actuator functions
are supplied with the LonWorks® network as standardized network variables
according to LonMARK®. The Node Object #0, the Damper Actuator Object #8110
and the Open Loop SensorObject #1 are implemented in the actuator.
Node object #0
The node object contains the object status and object request functions.
nviRequest
SNVT_obj_request
Input variable for requesting the status of a particular object in the node.
nvoStatus
SNVT_obj_status
Output variable that outputs the current status of a particular object in the node.
nvoFileDirectory
SNVT_address
Output variable that shows information in the address range of the Neuron chip.
Damper actuator object #8110
The actuator object is used to map the functions of the MP actuators to the
LONWORKS® network.
nviRelStpt
SNVT_lev_percent
The nominal position is assigned to the actuator via this input variable. This variable is
normally linked to the output variable of an HVAC controller.
nviActuateState
SNVT_switch
A preset position is assigned to the actuator via this input variable. Note on priority:
The last variable that was active, either nviActuatorState or nviRelStpt, has priority.
nviManOvrd
SNVT_hvac_overid
These input variables can be used to manually override the actuator into a particular
position.
nvoActualValue
SNVT_lev_percent
This output variable shows the current actual position of the actuator and can be used
for control circuit feedback or for displaying positions.
nvoAbsAngle
SNVT_angle_deg
This output variable shows the current angle of rotation of the actuator
or the valve and can be used to display the position or for service purposes.
Open loop sensor object #1
A sensor can be connected to the rotary actuator. A passive resistance sensor (e.g.
Ni1000), an active sensor (output 0 ... 32 V) or a switch (on/off) can be connected. The
open loop sensor object transfers the measured sensor values to the LONWORKS®
network.
nvoSensorValue
SNVT_xxx
This output variable shows the current sensor value. Depending on the connected
sensor, the output variable can be configured via the sensor plug-in and specifically
adapted to the system.
The SNVT_... can be configured as:
SNVT_temp_p
SNVT_lev_percent
SNVT_lux
SNVT_temp
SNVT_abs_humid
SNVT_press_p
SNVT_switch
SNVT_enthalpy
SNVT_smo_obscur
SNVT_flow
SNVT_ppm
SNVT_power
SNVT_flow_p
SNVT_rpm
SNVT_elec_kwh
Notes
Detailed information on the functional profiles can be found on the website of
LonMARK
K® (www.lonmark.org).
800-543-9038 USA
209
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
nvoAbsAirFlow
SNVT_flow
This output variable is inactive with the SR24ALON-5 rotary actuator and shows a
constant value of 65535 (this variable is only active in conjunction with LON-capable
VAV controllers).
GMX24-LON
®
LonWorks , Non-Spring Return, 24 V
1
2
3
4
M40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.
5
1 Direction of rotation switch
Switching over
Direction of rotation changes
2 Pushbutton and green LED display
Off
No voltage supply or malfunction
Operation
Green, on
Press button
Switches on angle of rotation adaption followed
by standard operation
3 Service button for commissioning LONWORKS® and
yellow LED display for the LON status
Off
The SR24ALON-5 rotary actuator is connected
and ready for operation in the
LONWORKS®network.
Yellow, on
No application software is loaded in the
SR24ALON-5.
Yellow, flashing
The SR24ALON-5 is ready for operation but not
(flashing interval 2 seconds)
integrated in the LONWORKS® network
(unconfigured).
Other flashing codes
A fault is present in the SR24ALON-5.
Press button
Service Pin Message is sent to the
LONWORKS®network.
4 Gear disengagement switch
Press button
Gear disengaged, motor stops, manual operation
possible
Release button
Gear engaged, synchronisation starts, followed
by standard operation
5 Service plug
For connecting MFT parameterizing and service tools
800-543-9038 USA
866-805-7089 CANADA
203-791-8396 LATIN AMERICA
210
Download