RD51Collaboration Meeting 08to11March2016 Dependenceontheincidenceangle andpressure ofRelativeExtraction Efficiency ofphotoelectrons froma CsI photocathode F.C.ROLO,F.I.G.M.BORGES,K. SA ITO,A .F.V. CORTEZ,C.A .N.COND E Laboratório deInstrumentação eFísica ExperimentaldePartículas (LIP-Coimbra) PhysicsDepartment UniversityofCoimbra Coimbra,Portugal E-mail:francisco.crolo@gmail.com Introdution RadiationDetectors Photoelectric Effect Radiationinputtoelectricaloutput Photocathodes - quantum efficiency #𝑒𝑚𝑖𝑡𝑒𝑑𝑒 ( #𝑝ℎ𝑜𝑡𝑜𝑛𝑠 Variationwithincidenceanglefor variousatmospheres § Importantforoptimisingthe performanceofdetectors § Fewdataavailableintheliterature ExperimentalSetup D2Lamp Quartzwindow Collimator CollectionGrid Photocathode stage Linearmotion feedthrough ExperimentalSetup Limitations: § BroadSpectraldistributionofthelamp § Complexityofthevacuumsystem->poor controlandknowledgeofthevacuumlevel § Evaporationofthephotocathode hastobe doneoutsidethesystem D2Lampspectraldistribution ExperimentalSetup Method AnglevariationMeasurement: 1) Measurethephotocurrent for0° 2) Measurethephotocurrent varyingtheangleby5° 3) Comparethosewith0° measures E/pvariationMeasurement: 1) Measurethephotocurrent for verylowreducedelectricfield (E/p) 2) VaryE/pandtakesomevaluesfor eachE/p 3) Comparethosewiththe reference Typical E/pMeasurement Photocurrent Photocurrent TypicalAngleMeasurement Time Time Fornow we mesured RelativePhotocurrent Xe- 1bar Xe- 3bar Xe- 2bar 35% 35% 35% 30% 30% 30% 25% 25% 25% 20% 20% 20% 15% 15% 15% 10% 10% 10% 5% 5% 5% 0% 0% 0 -5% 10 20 30 Angle(º) 40 50 60 0% 0 -5% 10 20 30 40 Angle(º) (𝑽 / 𝑻𝒐𝒓𝒓 (𝟏 / 𝒄𝒎(𝟏 ) 50 0 60 -5% 10 20 30 Angle(º) 40 50 60 Fornow we mesured Xe - 1bar Xe - 2bar RelativePhotocurrent (Reference:E/p=0) Xe - 3bar (Reference:E/p=0,005) (Reference:E/p=0,005) 140 14 14 120 12 12 100 10 10 80 8 8 60 6 6 40 4 4 20 2 2 0 0 0 0,2 0,4 0,6 0,8 E/p(VTorr-1cm-1) 1 0 0 0,2 0,4 0,6 E/p(VTorr-1cm-1) 0,8 1 0 0,2 0,4 0,6 E/p (VTorr-1cm-1) 0,8 1 Inthe future Inthenearfuturewewanttokeepthiskindofmeasurementsfor someothergaseousatmospheresandlatermaybeadaptthesystem sowecangetabsolutemeasurements. Withthissetupwecanalsostudytheresponseofthephotocathode withtheincidentangleforsomeotherparameters: § aging § humidity § substrate § heating § ... Conclusions §Thesystemgiveveryprecise reproducibleresults. §Measuments forXe at1,2and3bar wereperformedshowingsimilar behaviour. §ThevariationofREEwithE/pisnot angledependent. AngleVariation 35,00% Relativephotocurrent §Anexperimentalsystemtomeasurethe variationoftheRelativeExtraction Efficiency(REE)inphotocathodeswith thelightincidenceanglewasdeveloped. 30,00% 25,00% 20,00% 15,00% 10,00% 5,00% 0,00% -5,00% 0 10 Average 1bar 20 30 40 50 Angle(º) Average 2bar Average 3bar 60 Thank you...