APU Control Panel Module V1.5
Datasheet
Ed. 1
APU Control Panel Module (I4)
M-FOH-737-GL-I4-G-15
Datasheet - I4 APU Power Panel Module V1.5 - AA.docx
Module Dimensions:
228 x 146 x 25 mm3
(WxHxD) mm3
High of Knobs Not included
Module Lines:
Gold Line
Backlight (12V):
Yes, Warm White
Backpanel:
Yes, Specific PCB
Hardware Interface:
(See Chapter 1.3)
To be connected to a
Control Board like
SimCard Ethernet,
IOCard USB, etc.
Knobs:
Plastic Injection
Realistics Knobs
Extras:
Instrument Gauge
Plug Ready Module
Yes
Simulator Model:
737NG
Scale:
1:1
Price (without VAT):
Web: Shop
1 Compatibility
1.1 Software Compatibility
FS9
FSX
X-Plane
Prepar3D
Yes
Yes
Yes
Yes
1.2 Add-Ons Compatibility
iFly737
Prosim737
Project Magenta
SimAvionics
PMDG 737NG
Yes
Yes
Yes
Yes
-
1.3 Hardware Compatibility
SimCards Ethernet
IOCards
Phidgets
MIP737
Pokeys USB
Yes
Yes
Yes
Yes
No Information
This module has been designed to be connected directly to the “Sismo FWD Overhead Backpanel V1.5” or
superior. This backpanel is optional. If you want to use it in other configuration, then connect the flat
ribbon cables following the indications of the “Connections Map”.
www.sismo-soluciones.com
Page 1
APU Control Panel Module V1.5
Datasheet
Ed. 1
2 Abbreviations
FOH
FWD Overhead
PRM
Plug Ready Module
3 Parts included
•
•
1 APU Control Panel Module, fully assembled and ready to be installed in Pedestal.
2 flat ribbon cables 20 wires and 20cm length. For other lengths, please contact to Sismo.
4 Extras
Instrument Gauge by servo not included, go to the shop in www.sismo-soluciones.com to get this
instrument. Also “Dummy Gauge” price available by mail.
5 Backpanel Connectors
www.sismo-soluciones.com
Page 2
APU Control Panel Module V1.5
Datasheet
Ed. 1
6 Connections map
6.1 Inputs
6.1.1
P1-IN
Function
P1-IN
State
State
Function
Toggle Switch: GEN ON 1
ON
1
2
ON
Toggle Switch: GEN OFF 1
Toggle Switch: APU GEN ON 1
ON
3
4
ON
Toggle Switch: APU GEN OFF 1
Toggle Switch: APU GEN ON 2
ON
5
6
ON
Toggle Switch: APU GEN OFF 2
Toggle Switch: GEN ON 2
ON
7
8
ON
Toggle Switch: GEN OFF 2
9
10
12V+ CC for Panel Backlight
Common GND for Inputs 1 to 8
Toggle Switch: BUS TRANS OFF
ON
11
12
ON
Toggle Switch: GRD PWR ON
Toggle Switch: GRD PWR OFF
ON
13
14
ON
Rotary: L WIPER PARK
Rotary: L WIPER INT
ON
15
16
ON
Rotary: L WIPER LOW
Rotary: L WIPER HIGH
ON
17
18
19
20
12V+ CC for Panel Backlight
6.1.2
Not Used
B-GND
Common GND for Inputs 11 to 18
P2-OUT
Function
State
P2-OUT
State
Function
Ann: MAINT
ON
1
2
ON
Ann: GEN OFF BUS 1
Ann: APU GEN OFF BUS
ON
3
4
ON
Ann: GEN OFF BUS 2
Ann: GRD POWER AVAILABLE
ON
5
6
ON
Ann: LOW OIL PRESSURE
Ann: FAULT
ON
7
8
ON
Ann: OVER SPEED
9
10
Not used
Common GND for Outputs pins 1 to 8
Ann: SOURCE OFF 1
ON
11
12
ON
Ann: TRANSFER BUS OFF 1
Ann: SOURCE OFF 2
ON
13
14
ON
Ann: TRANSFER BUS OFF 2
Not used
15
16
GND for Backlight
12V+ CC for Panel Backlight
17
18
GND for Backlight
12V+ CC for Panel Backlight
19
20
Common GND for Outputs pins 11 to 18
6.2 Backlight
12-BL
12V for backlight. This voltage can be provided directly from a 12 V DC power supply or can
be provided by “dimmer backlight board” to have the dimming functionality available.
12-BL1
12V for backlight. This voltage can be provided directly from a 12 V DC power supply or can
be provided by “dimmer backlight board” to have the dimming functionality available.
Note: These connectors are not necessary because the power for backlight is available also in the
connector P2-OUT.
www.sismo-soluciones.com
Page 3
APU Control Panel Module V1.5
Datasheet
Ed. 1
7 DZUS Position
www.sismo-soluciones.com
Page 4
APU Control Panel Module V1.5
Datasheet
Ed. 1
8 FWD Overhead Backpanel (Optional)
With Sismo’s FWD Overhead Backpanel the connections between all the FWD Over modules and the
control electronic (SimCards Ethernet) is very easy and professional. The backpanel supports all the
functionality of the overhead, like backlight, dimming, power supply converter, extensions, etc.
I4 Panel
Ethernet Port
To Computer
www.sismo-soluciones.com
Page 5
APU Control Panel Module V1.5
Datasheet
Ed. 1
9 Related Documentation
ID
R1
DOCUMENT
FOH Modules connections with FWD Overhead Backpanel
V1.5 – AA
DESCRIPTION
Description of FWD Overhead Modules
connections with the specific FWD
Overhead Backpanel.