DOWNLIGHT ® BeveLED2.0 Trimless 3323 WARM GLOW DIMMING Covered By US Patent 8,456,109 and 8,581,520 1" REGRESS LED Dimmed to 50% LED Dimmed to 20% LED Dimmed to 1% Warm Glow Dimming gradually transitions from 2700K, 3000K or 3500K down to 2200K - creating intimacy while enhancing the mood and feeling of the space. DELIVERED PERFORMANCE DOWNLIGHT 16 Watts Max Max Color Temperature Color Rendering Index Lumens per Watt Source Lumens Delivered Lumens 2700K 80+ 90+ CRI CRI 52 41 1000 800 825 650 32 Watts Max 3000K 80+ 90+ CRI CRI 56 45 1075 875 900 725 3500K 2700K 80+ 80+ 90+ CRI CRI CRI 59 47 37 1150 1700 1325 950 1400 1100 3000K 80+ 90+ CRI CRI 50 40 1800 1450 1500 1200 3500K 80+ CRI 53 1925 1600 HOW TO SPECIFY Ordering Example: Specify trim code and housing code to order: Example : 3323W - B1 - S - 10 - LRLD4 - 9016 - WGD1 - 2722KS - 30 - NC - 277V - DIML4 - CB27 BeveLED 2.0 Warm Glow Dimming Curve vs. Actual Incandescent Dimming Curve TRIM ORDERING INFORMATION 3323 3323 Round Trimless Downlight 1" Regress BEVEL STYLE OPTION 1 Wet location, use with B1 trims only. 2 For use with NC housing only. B1 BEVEL FINISH – Wet location 1 Emergency 2 W EML LENS – ______ F Frosted S Solite (provided standard) B1 1" Regress Bevel, Painted Die Cast AB1 1" Regress Bevel, Black Anodized Finish AC1 1" Regress Bevel, Clear Matte Anodized Finish Warm Glow Dimming 3000K LED – 10 13 21 28 RAL WATTAGE – LRLD4 LRLD4 ENGINE CODE – 9016 16W LED, 900 lumens 9032 32W LED, 1500 lumens WGD1 WGD1 100% 90% 80% 70% 60% 50% 40% 30% F Frosted S Solite (provided (Leave blank for AB1 and AC1 Bevel Styles) standard) 20% 10% 0% 3000 2800 2900 2700 2600 2500 2400 Correlated Color Temperature (CCT) COLOR – REFLECTOR – HOUSING TYPE – – 30 30° beam 2722KS 2700K-2200K, 80+ CRI 50 50° beam 80 80° beam 3022KS 3000K-2200K, 80+ CRI 3522KS 3500K-2200K, 80+ CRI 2722KH 2700K-2200K, 90+ CRI 3022KH 3000K-2200K, 90+ CRI NC New Construction FT Flat Housing New Construction NCSM1 Narrow Width 3 1-1/4" ceiling max NCSM2 Narrow Width 3 2-1/4" ceiling max CP Chicago Plenum IC Insulation-Contact Rated / Airtight 2 Step MacAdam ellipse is standard for all See emergency solutions chart for EM options with these housings DIMMING DRIVER OPTIONS VOLTAGE – 120V 277V USAI Lighting www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 2300 2200 ACCESSORIES – CB27 27" C-Channel Bars DIML2 0-10V dim, 15% (provided standard) CB52 52" C-Channel Bars DIML4 Lutron Hi-Lume 1% EML Emergency battery 4 3-wire/ECO EMLW Emergency battery, DIML6A ELDO 0-10V 0.1%, wet location 4 logarithmic MLXX Millwork adapter 5 DIML6B ELDO 0-10V 0.1%, XX=Specify Color linear (10, 13, 21, 28, RAL) Millwork not wet DIML7 ELDO DALI 0.1% listed DIML8 ELDO DMX 0.1% 3 4 For use with NC or NCSM housings only. NCSM housing requires above ceiling access. 3 ® 100W A19 Lamp White Statuary Bronze Black Metalized Grey Custom Color (specify RAL #) HOUSING ORDERING INFORMATION HOUSING CODE Warm Glow Dimming 2700K LED LIGHT OUTPUT TRIM Note: N/A with FT. 5 ML not for use with NCSM1 housings. © 2014. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 01/07/2016 ® BeveLED2.0 Trimless WARM GLOW DIMMING DOWNLIGHT 3323 Covered By US Patent 8,456,109 and 8,581,520 TRIM INFORMATION 1" Regress 1" Regress 31⁄2" Ø Housing EM fixtures that are provided with an integral test switch are shipped with a hole in the glass lens for access. Refer to “EMERGENCY SOLUTIONS” chart to find out which fixtures have an integral test switch. FT NCSM* Above ceiling access required NC, 30º or 50º optic Through aperture NC, 80º optic 41⁄2" Ø New Construction Flat Housing - FT For Downlight Only X Through aperture X NC Wet Location Through aperture CP N/A X X X Chicago Plenum (16W) - CP IC / Airtight (16W) - IC New Construction w/ Emergency - EM 73/8" 73/8" 33/8”-3" 89/16" /8 -1" 5 /8"-1" 5 7" X IC N/A * NCSM + DIML8 cannot be offered with EM HOUSING INFORMATION New Construction Universal Style Housing - NC 3323 Emergency Solutions EM Integral Remote Inverter SERVICE Test Switch Test Switch By Others N/A X /8"-1" 5 Always 4" 7 /4” 1 5 7" 13" /8"-1" Chicago Plenum (32W) - CP IC / Airtight (32W) - IC 81/4” 81/2" 13" /8"-1" 5 185/8" (Plan View) 16" (Plan View) 221/8" (Plan View) 19" (Plan View) 7" 185/8" (Plan View) 221/8" (Plan View) 83/8" New Construction - Narrow Width 43/4" X" NCSM1: /8" - 1 /4" NCSM2:11/4" - 21/4" 5 1 81/4" 185/8" (Plan View) 19" (Plan View) 22(Plan View) 19" (Plan View) TRIM: 4-1/2"round aperture with a 1" regressed bevel retained by three ball plungers. Die cast aluminum bevel is available in white, statuary bronze, black, and metalized grey finishes. Also available in black anodized or clear matte anodized bevel. Custom color available (provide RAL#). FIELD REPLACEABLE DIMMING DRIVER: 0-10V, 100%-15% DIML2 solid state electronic constant current driver with a high power factor provided standard. Specify 120V or 277V. Driver complies with IEEE C62.41 surge protection. DIMMING OPTIONS: Multiple dimming drivers available. See compatibility chart attached. Note: DIML6A logarithmic control is intended for use with Lutron control systems; DIML6B linear control is intended for use with non-Lutron REFLECTOR: Interchangeable precision injection molded controls. DIML2 and DIML6 dimming drivers source 2mA. specular polycarbonate reflector optimized for 30°, 50° or EMERGENCY: Fixtures provided with an integral test 80° beam distribution. switch are provided with a hole in the glass lens as per FIELD REPLACEABLE LIGHT ENGINE: Available in 2 lumen the drawing above. Fixtures provided with a remote test packages: 16W (900 lm) and 32W (1500 lm). Engine is field switch are provided with a 24” lead length for location of replaceable through the aperture without tools. the test switch. Fixtures that have no USAI EM option may be connected to an inverter (by others) for emergency COLOR: BeveLED is available in 3 color temperatures with Warm Glow dimming. All color temperatures will dim down lighting. SPECIAL NOTE FOR NCSM HOUSING: DIML8 from initial CCT at 100% output to 2200K at minimum output. cannot be combined with EM options in NCSM housing. All color options are tightly binned for fixture-to-fixture color See emergency solutions chart for more information on EM test switches and servicing. consistency within a 2-Step MacAdam Ellipse. 80+ color rendering index provided standard. 90+ CRI also available. HOUSING: Fabricated of 20 ga. galvanized steel with thru wire J-box, 4 in 4 out at min. 90°C, #12 AWG thru branch RATED LIFE: Based on IESNA LM80-2008 50,000 hours at circuit wiring. 70% lumen maintenance (L70). TRIM LENS: Trim is shipped with integral solite lens standard; frosted lens available as an option. THERMAL MANAGEMENT: Proprietary high performance aluminum die cast heatsink for maximum LED life. Ambient temperatures at fixture location should not exceed 40°C during normal operation. USAI Lighting 221/8" (Plan View) 22(Plan View) SPECIFICATIONS ® 13" 83/8" Shown 53/4" with EM option www.usailighting.com info@usailighting.com MAXIMUM CEILING THICKNESS: As per drawings above. Millwork option is for 2-1/2" max. thickness wood with NCSM2 housing and for 1" max thickness wood with all other housings. Millwork option is not available with NCSM1 housing. CEILING CUT OUT: Mill Work: 413/16"Ø All others: 51/2"Ø LISTINGS: Dry/Damp. Millwork is dry/damp only. Wet location option available with B1 trim only. NRTL/CSA-US tested to UL standards. IBEW union made. WARRANTY: 5 years NOTES: • Not for use in corrosive environment. • Use of pressure washer voids warranty. • For interior use only • Not for use with acoustical ceilings. • Trimless for drywall installation only • Millwork option for non-spackle installations PHOTOMETRICS: Consult factory or website for IES files. Tested in accordance with IESNA LM79-2008. MOUNTING: Butterfly brackets and adjustable nailer bars with integral nails provided. Nailer bars are extendible from 14" to 24" centers. 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2014. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 01/07/2016 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DIML2 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). DIML2 LED: 0-10V Dimming Driver Wiring (Dims down to 10%) DIML2 Dimmer Compatibility Chart Manufacturer 120V / 277V Crestron Crestron Crestron Crestron Crestron Leviton Lightolier (Philips) Lutron Product Part Number Dimmed Light Output Range iLux dimmer expansion module DIN Rail dimmer DIN Rail analog output module 8 Channel dimmer module 8 Channel dimmer module IllumaTech dimmer Vega Diva CLS-EXP-DIMFLV DIN-4DIMFLV4 DIN-A08 GLX-DIMFLV8 GLXP-DIMFLV8 IP710-DLX V2000FAMU DVTV-XX 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% Qty Fixtures Per Dimmer* Use source current per fixture specification sheet to determine number of fixtures per dimmer. Max number of fixtures is limited by dimmer load rating. * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML2 0-10V DIMMING W/RELAY TO SWITCH POWER FIXTURE DIMMER: 0-10V (BY OTHERS) 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT BLACK NEUTRAL WHITE LED DRIVER V+ RED V- BLACK NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. GREEN GND CLASS 2 CONTROL WIRES LINE RELAY (BY OTHERS) NEUTRAL DIMMER: 0-10V w/ POWER SWITCHING DIML2 0-10V DIMMING (NO RELAY) FIXTURE (BY OTHERS) LINE 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT BLACK NEUTRAL WHITE LED DRIVER V+ RED V- BLACK NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. GREEN GROUND GND NEUTRAL USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-2 Revised 02/15/2016 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DIML4 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). DIML4 LED: Lutron Hi-Lume A-Series LED Driver with 3-Wire FL Control / LED Dimming Driver Wiring (Dims down to 1%) DIML4 3-Wire Dimmer Compatibility Chart Manufacturer 120V Only ETC ETC Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron 277V Only ETC ETC Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Product Part Number Dimmed Light Output Range Sensor+ Cabinet Unison DRd Cabinet Nova T Nova T Nova Nova Vareo Skylark Diva Ariadni Vierti Maestro Maestro Wireless RadioRA 2 HomeWorks QS Interfaces GP Dimming Panels D20 Dimming module D20F Dimming module NTF-10NTF-103PNF-10NF-103PVF-10SF-10P-, SF-103PDVF-103P-, DVSCF-103PAYF-103PVTF-6AMAF-6AM-, MSCF-6AMMRF2-F6AN-DVRRD-F6AN-DVHQRD-F6AN-DV PHPM-3F-120, PHPM-3F-DV Various 100% - 1% 100% - 1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% Sensor+ Cabinet Unison DRd Cabinet Nova T Nova T Nova Nova Skylark Diva Ariadni Vierti Maestro Maestro Wireless RadioRA 2 HomeWorks QS Interfaces GP Dimming Panels D20 Dimming module D20F Dimming module NTF-10-277NTF-103P-277NF-10-277NF-103P-277SF-12P-277-, SF-12P-277-3 DVF-103P-277-, DVSCF-103P-277AYF-103P-277VTF-6AMAF-6AM-277-, MSCF-6AM-277MRF2-F6AN-DVRRD-F6AN-DVHQRD-F6AN-DV PHPM-3F-DV Various 100% - 1% 100% - 1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% Qty Fixtures Per Control* Fixture Wattage 39W and Less 40W - 80W 1–53 1–26 1–53 1–26 1–41 1 – 20 1–20 1 – 10 1–41 1 – 20 1–20 1 – 10 1–20 1 – 10 1–20 1 – 10 1–20 1 – 10 1–20 1 – 10 1–15 1–7 1–15 1–7 1–15 1–7 1–15 1–7 1–15 1–7 1–41 1 – 20 1–41 1 – 20 40W and Less 41W - 80W 1–53 1–26 1–53 1–26 1–44 1 – 22 1–33 1 – 16 1–44 1 – 22 1–33 1 – 16 1–33 1 – 16 1–33 1 – 16 1–44 1 – 22 1–33 1 – 16 1–20 1 – 10 1–33 1 – 16 1–33 1 – 16 1–33 1 – 16 1–88 1 – 44 1–88 1 – 44 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML4 wiring diagrams continued on next page USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-4 Revised 02/15/2016 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DIML4 Continued ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). DIML4 LED: Lutron Hi-Lume A-Series LED Driver with 3-Wire FL Control / LED Dimming Driver Wiring (Dims down to 1%) DIML4 3 WIRE PHASE DIMMING FIXTURE DIMMER: 3 WIRE PHASE (BY OTHERS) CAP UNUSED ECOSYS WIRES DIMMED HOT SWITCHED HOT NEUTRAL LINE LED PURPLE GRAY PURPLE ORANGE BLACK WHITE GREEN GROUND DRIVER V+ RED V- BLACK GND NEUTRAL DIML4 LED: Lutron Hi-Lume A-Series LED Driver with EcoSystem Control / LED Dimming Driver Wiring (Dims down to 1%) Manufacturer 120V / 277V Lutron Lutron Lutron Lutron DIML4 EcoSystem Dimmer Compatibility Chart Dimmed Light Part Number Output Range Product PowPak dimming module Energi Savr Node GRAFIK Eye QS (120V ONLY) Quantum RMJ-ECO32-DV-B QSN-1ECO-S, QSN-2ECO-S QSGRJ-_E, QSGR-_E Various 100%–1% 100%–1% 100%–1% 100%–1% Qty Fixtures Per Control* Fixture Wattage 39W and Less 40W - 80W 1–32 1 – 16 1–64 1 – 32 1–64 1 – 32 1–64 1 – 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML4 EcoSystem CONTROLS ECOSYS BUS E2 E1 E2 FIXTURE E1 WALL CONTROL (BY OTHERS) LINE NEUTRAL CAP UN-USED ORANGE WIRE PURPLE GRAY PURPLE ORANGE BLACK WHITE GREEN LED DRIVER V+ RED V- BLACK GND USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-4 Revised 02/15/2016 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DIML6A, 6E DIML6B, 6F ® USAI Lighting IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). DIML6A and DIML6E LED Dimming Compatibility Table DIML6A and DIML6E are linearly programmed dimming drivers for use with logarithmic-style dimming controls (e.g., Lutron and others listed in the table below) DIML6A = EldoLED SOLOdrive 0-10V control dims from 100% to 0.1% DIML6E = EldoLED ECOdrive 0-10V control dims from 100% to 1% Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* Refer to manufacturer's 120V & 277V DIML6A / E Lutron Diva DVTV/NFTV/NTFTV with PP-20 99% - 0.1% / 1% dimmer load rating for Lutron Energi Savr Node QSN-4T16-S 100% - 0.1% / 1% maximum and minimum Lutron GP Dimming Panels TVM2 Module 99% - 0.1% / 1% fixture quantities per Lutron Interfaces GRX-TVI w/ GRX3503 100% - 0.1% / 1% dimmer. Sensor Switch nIO nIO EZ 100% - 0.1% / 1% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML6B and DIML6F LED Dimming Compatibility Table DIML6B and DIML6F are logarithmic-programmed dimming drivers for use with linear-style dimming controls (e.g., Crestron, non-Lutron and others listed in the table below) DIML6B = EldoLED SOLOdrive 0-10V control dims from 100% to 0.1% DIMMER: 0-10V DIML6F = EldoLED ECOdrive (BY OTHERS) 0-10V control dims from 100% to 1% 0-10V (-) GRAY 0-10V (+) PURPLE LED DIML6B Dimmer Compatibility Chart Dimmed Light Qty Fixtures V+ RED SWITCHED HOT SWITCHED HOTNumber DRIVER Manufacturer Product Part Output Range Per Dimmer* VBLACK NEUTRAL WHITE Refer to 120V & 277V DIML6B / F GREEN 2112U-101 Bush-Jaeger Electronic potentiometer 100% - 0.1% / 1% manufacturer's Jung Electronic potentiometer 100% - 0.1% / 1% dimmer load GND 240-10 CLASS 2 CONTROL WIRES Leviton IllumaTech dimmer IP710-DLX 100% - 0.1% / 1% rating for LINE Lightolier (Philips) Momentum (120V ONLY) ZP600FAM120 100% - 0.1% / 1% maximum and RELAY Merten Electronic potentiometer 5729 100% - 0.1% / 1% minimum fixture (BY OTHERS) DIML6A, 6B Pass & Seymour Titan CD4FB-W 100% - 0.1% / 1% quantities per NEUTRAL TO SWITCH POWER Watt Stopper Miro 0-10V DIMMING W/RELAY DCLV1 100% - 0.1% / 1% dimmer. Synergy Wallbox Dimmers ISD BC 100% - 0.1% / 1% ABB i-bus SD/S 2.16.1 100% - 0.1% / 1% Crestron Modules GLX-DIMFLV8, GLXP-DIMFLV8 100% - 0.1% / 1% Crestron Green Light GLPAC-DIMFLV4-, GLPAC-DIMFLV8100% - 0.1% / 1% DIML6A, 6B 0-10V (-) Crestron Green Light Power Pack GLPP-DIMFLVEX-PM, GLPP-1DIMFLV2EX-PM, GLPP-1DIMFLV3EX-PM 100% - 0.1% /FIXTURE 1% 0-10V DIMMING W/RELAY TO GRAY SWITCH POWER 0-10V (+) PURPLE DIMMER: 0-10V Crestron DIN Rail Analog Output Module DIN-A08 100% - 0.1% / 1% V+ RED SWITCHED HOT BLACK Crestron DIN Rail 0-10V Fluorescent Dimmer DIN-4DIMFLV4 100% - 0.1% / 1% LEDV- BLACK NEUTRAL WHITE GREEN Crestron iLux 0-10V Dimmer Expansion Module CLS-EXP-DIMFLV 100% - 0.1% / 1% DRIVER GND * NOTE: Refer to dimmer manufacturer's documentation for installation instructions andCLASS circuit details. 2 CONTROL WIRES (BY OTHERS) LINE DIMMING DRIVER WIRING SCHEMES: RELAY (BY OTHERS) NOTES: NEUTRAL Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. DIML6 0-10V DIMMING (NO RELAY) DIML6 0-10V DIMMING W/RELAY TO SWITCH POWER FIXTURE (BY OTHERS) 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT BLACK NEUTRAL WHITE (BY OTHERS) LED DRIVER V+ RED V- BLACK LINE GREEN GROUND GND 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT BLACK NEUTRAL WHITE LED DRIVER V+ RED V- BLACK GREEN GND CLASS 2 CONTROL WIRES LINE FIXTURE DIMMER: 0-10V w/ POWER SWITCHING DIMMER: 0-10V RELAY (BY OTHERS) NEUTRAL NEUTRAL USAI Lighting ® www.usailighting.com DIML6A, 6B info@usailighting.com 1126 River Road New Windsor, NY 12553 0-10V DIMMING (NO RELAY) DIMMER: 0-10V w/ POWER SWITCHING (BY OTHERS) FIXTURE T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-6 Revised 05/20/2016 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DIML7 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). DIML7 LED: EldoLED DALI Dimming Driver Wiring (Dims down to 0.1%) DIML7 DALI CONTROLS DALI BUS DA DA FIXTURE WALL CONTROL (BY OTHERS) LINE NEUTRAL LED ORANGE (-) ORANGE/WHITE (+) BLACK WHITE GREEN DRIVER V+ RED V- BLACK GND USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-7 Revised 02/15/2016 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DIML8 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). DIML8 LED: EldoLED DMX Dimming Driver Wiring (Dims down to 0.1%) DMX BUS - XLR CABLE OR SHIELDED DATA CABLE The data cable used must meet the following requirements: • type: shielded, 2-conductor twisted pair • maximum capacitance between conductors: 30 pF/ft • maximum capacitance between conductor and shield: 55 pF/ft • maximum resistance: 0.02 ohms/ft • normal impedance: 100-140 ohms • conductive core: 24 AWG is recommended If 3-wire data cables are preferred, we suggest a Belden 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Do not use standard microphone cables: they cannot transmit DMX512 data reliably over long distances. NOTE: DMX link termination device (by others) should be used on last fixture in line on a circuit to avoid signal loss. DMX BUS - XLR CABLE OR SHIELDED DATA CABLE SHIELD DMX (-) DMX (+) 5 PIN XLR JACKS STANDARD 8 BIT DMX 512 CONTROLLER (BY OTHERS) LINE NEUTRAL RED BLACK BARE BLACK WHITE GREEN LED DRIVER V+ RED V- BLACK GND FIXTURE USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-8 Revised 02/15/2016