Automotive Outdoor Retail Lighting Design Guide

advertisement
Automotive Outdoor
Retail Lighting Design Guide
Making the Right Choices with
™
Good Outdoor Retail Lighting Is Essential
LSI Automotive Lighting offers you the Power of Choice.
We’ve taken exterior lighting to an entirely new level with ART (Advanced Reflector Technology). Just like in your
showroom, ART allows you to specifically highlight your merchandise, maximizing your selling efforts. Available with
Automotive Forward Throw (AFT) and Automotive Interior (AI) reflectors, these optical systems maximize fixture
™
efficiency and uniformity, allowing you to utilize lower wattage lamps for your front row feature display and
interior row general auto merchandise sales areas. This innovative system is the result of the synergy created between a highly advanced reflector design
and a variety of lamp and fixture choices. Whether you are building a new site, or upgrading an existing dealership, LSI has an ART solution for you.
Delivering the effectiveness of
retail showroom lighting outdoors
Photo showing 750-watt ART application at Sam Pack’s Five Star Ford, Carrollton, TX.
ART – More flexibility than ever before!
• Utilizes vertical lamp orientation for
enhanced uniformity
• Best lighting available for both front and
interior row vehicle displays:
• IESNA cutoff –
- Full cutoff available with the
Greenbriar Reduced Flat Lens
- Title 24 compliant
- 1000-watt metal halide performance
from a 750-watt pulse-start system
• Energy savings
- Performance enhanced 1000-watt
metal halide system
• Lower total cost of ownership
The ART Retrofit Kit* comes with everything you
need to retrofit your existing LSI fixtures:
• ART Reflector
• Ballast
• 750-watt pulse start or 1000 metal halide lamp
*kit may vary with fixtures - Consult Factory
2
™
Making the Right Choices With ART
Whether a new build or retrofit, every outdoor retail facility has its own footprint and unique lighting requirements. LSI recognizes the many issues
retailers face today – irregular sized lots, zoning constraints, energy restrictions, and corporate specifications. Our palette of lighting options address all
of the above and more.
IESNA Recommended Illuminances
The IESNA (Illuminating Engineering Society of North America)
provides recommended illuminances based upon specific
applications or tasks for a variety of environments. Outdoor
lighting presents several challenges given a number of visual
considerations such as brightness, glare, visual acuity and the eye’s
ability to adapt to varying light levels.
CIRCULATION
CIRCULATION
CIRCULATION
INTERIOR ROW MERCHANDISE
Typical
Auto Dealership
INTERIOR ROW MERCHANDISE
CIRCULATION
The chart below reflects the IESNA recommendations for general
exterior lighting at automotive dealerships. The levels established
by IESNA are ‘maintained levels’* which take into account lamp
depreciation and other specific field conditions. This LSI Design
Guide provides typical spacing recommendations that fall within
the IESNA guidelines.
CIRCULATION
MERCHANDISE
INTERIOR ROW MERCHANDISE
INTERIOR ROW MERCHANDISE
INTERIOR ROW MERCHANDISE
FEATURE DISPLAY
FEATURE DISPLAY
Excerpted from Table H1 in the IESNA Recommended Practice for Lighting Merchandising
Areas (RP-2-01), 2001, courtesy of the Illuminating Engineering Society of North America.
Area to Illuminate
Target Maintained Levels*
(foot-candles)
Description
High
Medium
Low
Feature Display
Front Row presentation and or autos on feature
stands.
75
50
35
Merchandise
General Auto Sales or area of merchandise
presentation.
50
30
20
Circulation
Area not used for merchandise sales or
display, also approach and parking area.
10
7
5
* Maintained Levels: Illumination levels that reflect a total light loss factor based upon factors such as lamp lumen depreciation, luminaire dirt
depreciation, ballast factor, and other recoverable and non-recoverable factors.
Energy savings calculator
This chart will help you
determine the cost savings
when switching from a 1000watt system to a 750-watt
pulse-start system using ART.
1. Current Fixture’s Watts (i.e. 1000 watt)
2. Alternative Fixture’s Watts (i.e. 750 watt)
3. Operating Hours per Year (i.e. 4,000 hours/year)
4. Cost per Watt ($ . 08 per Kwh)
Energy Savings Per Year = ( 1 - 2 ) x 3 x 4
1000
= $ ________savings per fixture per year x # of fixtures
3
Flat Lens Optical Systems
Community Friendly Products for light sensitive areas.
Flat-lensed fixtures meet IESNA
full cutoff classification.
To meet the demands of today’s zoning requirements for light control, LSI
Automotive Lighting offers a selection of flat lens vertical burn and horizontal
burn fixtures. These high performance flat lens fixtures meet IESNA
requirements for full cutoff classification, making them Community Friendly.
LSI’s Greenbriar Reduced flat lens (GFR) optical system provides high
performance lighting with reduced light spill, uplight and glare to meet
today’s zoning requirements for lighting. This flat lens fixture combines
the benefits of vertical burn technology with the full cutoff advantages of
a flat lens, making the GFR Community Friendly.
Internal and External House Side Shield
Anodized Internal Louver is
available for architectural
appeal.
External House Side Shield
available for maximum
shielding.
Greenbriar® Series
Available with a complementary
wall sconce – a final touch to your
dealership design
5-3/8”
Bottom View
Bottom View
Front Row Feature Display
*High Competition: 70-100FC+ Initial Average
*Medium Competition: 50-70FC Initial Average
24’ Mounting Height / Foot-candles at 3’ Above Grade
System
Initial Average
Maintained Average**
Minimum
Max./Min. Uniformity
Front Row 40' O.C.
GFR-AFT-750-PSMV-F-D180
GFR-AFT-1000-MHR-F-D180
91.75
127.50
66.06
91.80
62.00
93.00
2.00
1.92
Front Row 50' O.C.
GFR-AFT-750-PSMV-F-D180
GFR-AFT-1000-MHR-F-D180
73.40
102.00
52.85
73.44
51.00
66.00
1.76
2.35
Front Row levels do not include contributions from Interior Rows.
*Refer to table H1 IESNA “Recommended Illuminances Chart” (pg. 3). Initial levels to be multiplied by appropriate light loss factor for maintained levels.
**Maintained light loss factor based upon industry standard 0.72 factor. Lamp factor can vary by lamp manufacturer and specific field conditions.
40’ O.C. D180 Rotated Optics
GFR-AFT-750-PSMV-F
Initial Average: 91.75
Maintained Average: 66.06
Minimum: 62.00
Max./Min. Uniformity: 2.00
4
™
Front Row – Feature Display
Flat lens vertical burn fixtures meet IESNA (Illuminating Engineering Society of North America) requirements for full cutoff classification,
making them Community Friendly. Specially designed Automotive Front Row AFT reflectors place lighting where it is needed for front row
illumination.
High competition initial foot-candle (FC) levels should range between 70 and 100 FC+ and medium competition initial levels should be
in the 50-70 FC range. Appropriate light loss factors should be used in conjunction with these levels to approximate maintained levels of
illumination. Refer to table H1 IESNA chart (pg. 3) for suggested maintained foot-candle levels.
40’ O.C. D180 Rotated Optics
GFR-AFT-1000-MHR-F
Initial Average: 127.50
Maintained Average: 91.80
Minimum: 93.00
Max./Min. Uniformity: 1.92
50’ O.C. D180 Rotated Optics
GFR-AFT-750-PSMV-F
Initial Average: 73.40
Maintained Average: 52.85
Minimum: 51.00
Max./Min. Uniformity: 1.76
50’ O.C. D180 Rotated Optics
GFR-AFT-1000-MHR-F
Initial Average: 102.00
Maintained Average: 73.44
Minimum: 66.00
Max./Min. Uniformity: 2.35
Front Row Color Scale
The above radiosity analysis shows the lighting distribution. The color shading reflects foot-candle readings.
5
Flat Lens Optical Systems
Interior Row – Merchandise Display
Flat-lensed fixtures meet IESNA
full cutoff classification.
To meet the demands of today’s zoning requirements for light control, LSI
Automotive Lighting offers a selection of flat lens vertical burn and horizontal
burn fixtures. These high performance flat lens fixtures meet IESNA
requirements for full cutoff classification, making them Community Friendly.
Greenbriar Reduced flat lens vertical burn fixtures meet IESNA (Illuminating
Engineering Society of North America) requirements for full cutoff classification,
making them Community Friendly. Specially designed Automotive Interior Type
AI reflectors provide symmetrical, uniform distribution for interior general auto
sales display areas.
High competition initial foot-candle (FC) levels should range between 40 and 70 FC and medium
competition initial levels should be in the 30-40 FC range. Appropriate light loss factors should be used
in conjunction with these levels to approximate maintained levels of illumination. Refer to table H1
IESNA chart (pg. 3) for suggested maintained foot-candle levels.
Featuring ART Optics
Interior Row Merchandise Display
*High Competition: 40-70FC Initial Average
*Medium Competition: 30-40FC Initial Average
24’ Mounting Height / Foot-candles at 3’ Above Grade
System
Initial Average
Maintained Average**
Minimum
Max./Min. Uniformity
Interior Row 60' O.C.
GFR-AI-750-PSMV-F-D180
GFR-AI-1000-MH-F-D180
GFR-AI-750-PSMV-F-T90
GFR-AI-1000-MH-F-T90
42.67
57.67
63.94
86.47
30.72
41.52
46.04
62.26
32.00
44.00
45.00
61.00
1.63
1.52
1.71
1.67
Interior Row 70' O.C.
GFR-AI-750-PSMV-F-D180
GFR-AI-1000-MH-F-D180
GFR-AI-750-PSMV-F-T90
GFR-AI-1000-MH-F-T90
36.48
49.33
54.81
74.08
26.27
35.52
39.46
53.34
27.00
40.00
40.00
56.00
1.70
1.60
1.83
1.75
Interior Row 80' O.C.
GFR-AI-750-PSMV-F-T90
GFR-AI-1000-MH-F-T90
47.96
64.81
34.53
46.66
31.00
38.00
2.29
2.53
Interior Row levels include contributions from adjacent Interior Rows.
*Refer to table H1 IESNA “Recommended Illuminances Chart” (pg. 3). Initial levels to be multiplied by appropriate light loss factor for maintained levels.
**Maintained light loss factor based upon industry standard 0.72 factor. Lamp factor can vary by lamp manufacturer and specific field conditions.
60’ O.C. D180 Optics
GFR-AI-750-PSMV-F
Initial Average: 42.67
Maintained Average: 30.72
Minimum: 32.00
Max./Min. Uniformity: 1.63
6
™
Interior Row – Merchandise Display
60’ O.C. T90 Optics
GFR-AI-750-PSMV-F
Initial Average: 63.94
Maintained Average: 46.04
Minimum: 45.00
Max./Min. Uniformity: 1.71
70’ O.C. D180 Optics
GFR-AI-1000-MHR-F
Initial Average: 49.33
Maintained Average: 35.52
Minimum: 40.00
Max./Min. Uniformity: 1.60
80’ O.C. T90 Optics
GFR-AI-1000-MHR-F
Initial Average: 64.81
Maintained Average: 46.66
Minimum: 38.00
Max./Min. Uniformity: 2.53
Interior Row Color Scale
The above radiosity analysis shows the lighting distribution. The color shading reflects foot-candle readings.
7
Contoured Lens Optical Systems
LSI’s ART Optical System for contoured lens fixtures maximizes light distribution providing for broader lighting coverage in an even and
uniform distribution pattern. Available with Automotive Forward Throw (AFT) and Automotive Interior (AI) reflectors, these optical systems
maximize fixture efficiency and uniformity, allowing you to utilize lower wattage lamps for your front row feature display and
interior row general auto merchandise sales areas. These optical systems can be used in LSI’s Challenger, Greenbriar Reduced, and Hilton
contoured lens fixtures to provide high performance, energy-efficient lighting across your lot.
Featuring ART Optical Systems
Greenbriar® Series
Hilton® Series
Challenger® Series
The Challenger, Greenbriar, and Hilton families are all available with complementary
wall sconces – a final touch to your dealership’s design.
Front Row Feature Display
*High Competition: 70-100FC+ Initial Average
*Medium Competition: 50-70FC Initial Average
24’ Mounting Height / Foot-candles at 3’ Above Grade
System
Initial Average
Maintained Average**
Minimum
Max./Min. Uniformity
Front Row 40' O.C.
CHV/GBR/HR-AFT-750-PSMV-CT-D180
CHV/GBR/HR-AFT-1000-MHR-CT-D180
86.06
129.08
61.96
92.94
72.00
107.00
1.49
1.36
Front Row 50' O.C.
CHV/GBR/HR-AFT-750-PSMV-CT-D180
CHV/GBR/HR-AFT-1000-MHR-CT-D180
68.87
103.27
49.59
74.35
57.00
73.00
1.60
1.73
Front Row 60' O.C.
CHV/GBR/HR-AFT-750-PSMV-CT-D180
CHV/GBR/HR-AFT-1000-MHR-CT-D180
55.61
86.11
40.04
62.00
32.00
43.00
2.66
2.79
Front Row levels do not include contributions from Interior Rows.
*Refer to table H1 IESNA “Recommended Illuminances Chart ” (pg. 3). Initial levels to be multiplied by appropriate light loss factor for maintained levels.
**Maintained light loss factor based upon industry standard 0.72 factor. Lamp factor can vary by lamp manufacturer and specific field conditions.
8
™
Front Row – Feature Display
LSI’s AFT optical system with 750-watt pulse-start lamp with contoured lens provides enhanced performance and improved uniformity
in front row automotive lighting, as compared to current industry standard horizontal or vertical burn 1000-watt optical systems. With a
1000-watt lamp, the AFT optical system enables up to 60’ spacing of front row assemblies for high competition areas while maintaining
uniformity.
High competition initial foot-candle (FC) levels should range between 70 and 100 FC+ and medium competition initial levels should be
in the 50-70 FC range. Appropriate light loss factors should be used in conjunction with these levels to approximate maintained levels of
illumination. Refer to table H1 IESNA chart (pg. 3) for suggested maintained foot-candle levels.
40’ O.C. D180 Rotated Optics
CHV/GBR/HR-AFT-750-PSMV-CT
Initial Average: 86.06
Maintained Average: 61.96
Minimum: 72.00
Max./Min. Uniformity: 1.49
50’ O.C. D180 Rotated Optics
CHV/GBR/HR-AFT-750-PSMV-CT
Initial Average: 68.87
Maintained Average: 49.59
Minimum: 57.00
Max./Min. Uniformity: 1.60
60’ O.C. D180 Rotated Optics
CHV/GBR/HR-AFT-1000-MHR-CT
Initial Average: 86.11
Maintained Average: 62.00
Minimum: 43.00
Max./Min. Uniformity: 2.79
Front Row Color Scale
The above radiosity analysis shows the lighting distribution. The color shading reflects foot-candle readings.
9
Contoured Lens Optical Systems
Interior Row – Merchandise Display
LSI’s ART Optical System for contoured lens fixtures maximizes light distribution providing for broader lighting
coverage in an even and uniform distribution pattern. Utilizing a 750-watt pulse-start lamp, the AI optical system
for interior row automotive lighting provides enhanced performance over current industry standard
horizontal or vertical burn 1000-watt optical systems for assembly spacing up to 70’ on center. The 1000watt Type 5 optical system is suggested for assembly spacing greater than 70’.
Featuring ART Optics
High competition initial foot-candle (FC) levels should range between 40 and 70 FC+ and medium competition
initial levels should be in the 30-40 FC range. Appropriate light loss factors should be used in conjunction
with these levels to approximate maintained levels of illumination. Refer to table H1 IESNA chart (pg. 3) for
suggested maintained foot-candle levels.
Interior Row Merchandise Display
Design Choices
*High Competition: 40-70FC+ Initial Average
*Medium Competition: 30-40FC Initial Average
24’ Mounting Height / Foot-candles at 3’ Above Grade
System
Initial Average
Maintained Average**
Minimum
Max./Min. Uniformity
Interior Row 60' O.C.
CHV/GBR/HR-AI-750-PSMV-CT-D180
CHV/GBR/HR-AI-1000-MHR-CT-D180
CHV/GBR/HR-AI-750-PSMV-CT-T90
CHV/GBR/HR-AI-1000-MHR-CT-T90
43.83
58.78
65.34
88.05
31.56
42.32
47.04
63.40
30.00
47.00
44.00
70.00
1.80
1.51
1.86
1.54
Interior Row 70' O.C.
CHV/GBR/HR-AI-750-PSMV-CT-D180
CHV/GBR/HR-AI-1000-MHR-CT-D180
CHV/GBR/HR-AI-750-PSMV-CT-T90
CHV/GBR/HR-AI-1000-MHR-CT-T90
37.48
50.33
55.95
75.51
26.99
36.24
40.28
54.37
27.00
35.00
39.00
51.00
1.93
1.97
2.03
2.06
Interior Row levels include contributions from adjacent Interior Rows.
*Refer to table H1 IESNA “Recommended Illuminances Chart” (pg. 3). Initial levels to be multiplied by appropriate light loss factor for maintained levels.
**Maintained light loss factor based upon industry standard 0.72 factor. Lamp factor can vary by lamp manufacturer and specific field conditions.
60’ O.C. D180 Optics
CHV/GBR/HR-AI-750-PSMV-CT
Initial Average: 43.83
Maintained Average: 31.56
Minimum: 30.00
Max./Min. Uniformity: 1.80
10
™
Interior Row – Merchandise Display
60’ O.C. T90 Optics
CHV/GBR/HR-AI-750-PSMV-CT
Initial Average: 65.34
Maintained Average: 47.04
Minimum: 44.00
Max./Min. Uniformity: 1.86
70’ O.C. D180 Optics
CHV/GBR/HR-AI-1000-MHR-CT
Initial Average: 50.33
Maintained Average: 36.24
Minimum: 35.00
Max./Min. Uniformity: 1.97
70’ O.C. T90 Optics
CHV/GBR/HR-AI-1000-MHR-CT
Initial Average: 75.51
Maintained Average: 54.37
Minimum: 51.00
Max./Min. Uniformity: 2.06
Interior Row Color Scale
The above radiosity analysis shows the lighting distribution. The color shading reflects foot-candle readings.
11
LSI - the leading producer of
Image Solution programs.
LSI – A Smart Energy Solution from a U.S. Company
As an environmentally conscientious company, LSI is a member of the Next Generation Lighting Industry
Alliance (NGLIA) which is the official U.S. Department of Energy’s industry partner designated under the
Energy Policy Act of 2005 (EPACT). We are proud to be a part of this effort to accelerate the promotion of
solid-state lighting development and commercialization through this government-industry partnership.
We are committed to manufacturing environmentally driven
products throughout our locations in the U.S.
Solid-state lighting is the future.
For further information,
consult LSI at 1-800-436-7800, ext. 3045,
contact your local representative or visit us at
www.lsi-industries.com
LSI AUTOMOTIVE LIGHTING
10000 Alliance Road ◆ Cincinnati, Ohio 45242 ◆ (513)793-3200
©2007 LSI INDUSTRIES INC.
Fax: (513)793-0147 ◆ www.lsi-industries.c
12/07 3000 3303