Three-way reversing valve Thermostatic 3-way control valves For heating and cooling systems IMI HEIMEIER / Thermostatic heads and Radiator valves / Three-way reversing valve Three-way reversing valve Three-way reversing valve for the distribution of mass flow in heating and cooling systems. Key features >> Valve body in gunmetal >> Stainless spindle with double >> For all IMI Heimeier thermostatic >> Outer O-ring can be replaced while O-ring seal corrosion-resistant and safe heads and actuators under pressure Technical description Three-way reversing valve for the distribution of mass flow in heating and cooling systems, made of gunmetal, with protection cap. Stainless spindle has double O-ring seal. Outer O-ring can be replaced without draining the system. Models: flat sealing, and flat sealing with T-piece. Connection with threaded, soldering, or welding nipples. Low-pressure steam 110°C (230°F)/ 0.5 bar. Models: conically sealing DN 15, G3/4 male thread. Connection with IMI Heimeier compression fittings for plastic, coppe or precision steel pipes. Allowable differential pressure Maximum allowable working pressure 10 bar. Construction Three-way reversing valve I II III 2 DN 15 = 1.20 bar DN 20 = 0.75 bar DN 25 = 0.50 bar Function The EMO T (brochure: EMO T) thermal actuator is used for two-step control with auxiliary power. In the model normally open (NO), the straight passage I-II of the three-way reversing valve is open without, and the angled exit I-III is closed without current. In the model normally closed (NC), the straight passage I-II of the three-way reversing valve is closed without, and the angled exit I-III is open without current. Thermostatic heads (brochure: Thermostatic Head K with contact or immersion sensor and/or thermostatic heads) are used for proportional control without auxiliary power. They also operate in intermediate positions. When the temperature rises, the straight passage I-II is closed and the angled exit I-III is opened. The EMO 1, EMO EIB, EMOLON, and/or EMO 3 / EMO 3/230 motorized actuators are used for proportional and/or three-step control with auxiliary power. The effective direction is determined by the controller or the connection (brochure: EMO, EMO EIB, EMOLON). Application Distributing function – Switching between heat consuming apparatuses such as the heating circuit and heater for potable water or between various heat generating devices such as boilers, heat pumps, or solar energy systems. –O utput control of heat exchangers via flow rate control, e.g. for air heaters, coolers or other heat exchangers. Volume flow remains steady in the primary circuit. Mixing function – Mixing control through installation in the return pipe (external mixing point). Approximately equal volume flow in the secondary circuit. Principle Pay attention to the flow direction, see function. Distributing function Mixing function Mischpunkt II I III III II I 3 IMI HEIMEIER / Thermostatic heads and Radiator valves / Three-way reversing valve Sample application A D 1. Oil/gas boiler 2. Heating circuit 3. Hot water storage 4. Boiler for solid fuels 5. Heat exchanger 6. Air heater 7. Fan-coil device 8. STAD balancing valve 9. Primary circuit 10. Secondary circuit Note The composition of the heat transfer medium should be one which avoids damage or the accumulation of stones in hot water heating systems, in accordance with VDI guide line 2035. For industrial and long-distance energy systems, see applicable codes VdTÜV and 1466/AGFW FW 510. Heat transfer media containing mineral oils or lubricants containing mineral oil can have seriously negative effects on the source apparatus and usually lead to the disintegration of EPDM seals. 4 B C E A. S witching between heat consumers such as heating circuits and hot water storages with e. g. EMO T. B. S witching between heat generating devices such as an oil/ gas boiler or boilers for solid fuels with e. g. EMO T. C. F low rate control for constant blow-out temperature with air heaterswith thermostatic head K with contact sensor. D. S witching with fixed-command control of the flow temperature to a secondary circuit of the heat exchanger, such as heaters for potable water, industrial pools, and swimming pool water with thermostatic head K with contact sensor. E. Control of the water circuit from fan-coil devices (air conditioners / forced air convectors) with e. g. EMO T. When using nitrite-free frost and corrosion resistance solutions with an ethylene glycol base, pay close attention to the details outlined in the manufacturers’ documentation, particularly details concerning concentration and specific additives. Technical data Diagram – Three-way reversing valve with actuator DN 25 (Kvs 5,12) DN 20 (Kvs 3,48) DN 15 (Kvs 2,47) 5000 30 300 3000 20 200 2000 10 100 1000 5 50 500 3 30 300 2 20 200 1 10 100 0,5 5 50 0,3 3 30 0,2 2 20 0,1 50 100 200 300 500 1000 1 2000 3000 5000 10 ∆p [mm WS] 500 ∆p [mbar] ∆p [kPa] DN 15 (Kvs 2,25) 50 m [kg/h] Three-way reversing valve with Thermostatic head K *) Three-way reversing valve with immersion/ sensor Kv-value P-band [K] Kvs 2,0 4,0 6,0 8,0 0,60 1,20 1,71 2,10 2,47 0,57 1,11 1,58 2,00 2,25 DN 20 0,70 1,50 2,39 3,10 3,48 DN 25 1,08 2,28 3,48 4,62 5,12 DN 15 DN 15 with T-piece *) The Kv values correspond to the flow in the direction of passage I-II at the given system deviations. With the models without T-piece the kvs-values corresponds to the flow in the direction I-II with a completely opened valve and in the direction I-III with a closed valve. With the models with T-piece the Kv/Kvs-values corresponds to the flow in the direction I-II. Sample calculation Goal: Pressure loss ΔpV Given: Three-way reversing valve DN 25 with thermal actuator Heat flow Q = 21000 W Temperature adjustment Δt = 20 K (70/50°C) Solution: Mass flow m = Q / (c · Δt) =21000 / (1,163 · 20) = 903 kg/h Pressure loss from diagram ΔpV = 31 mbar Cv = Kv 0,86 Kv = Cv · 0,86 5 IMI HEIMEIER / Thermostatic heads and Radiator valves / Three-way reversing valve Articles Three-way reversing valve Flat sealing DN EAN Article No 15 20 25 4024052222711 4024052223114 4024052223510 4160-02.000 4160-03.000 4160-04.000 With T-piece, Flat sealing DN EAN Article No 15 4024052226016 4162-02.000 Conically sealing with compression fittings for CU-pipe, ø 15 mm. Male thread G3/4 DN EAN Article No 15 4024052225910 4161-15.000 Conically sealing. Male thread G3/4 6 DN EAN Article No 15 4024052323654 4161-02.000 Accessories – Flat sealing Connecting nipple for flat sealing three-way reversing valves DN valve EAN Article No Threaded nipple 15 (1/2”) R1/2 20 (3/4”) R3/4 25 (1”) R1 4024052222810 4024052223213 4024052223619 4160-02.010 4160-03.010 4160-04.010 Soldered nipple Ø Pipe 15 (1/2”) 15 15 (1/2”) 18 20 (3/4”) 22 25 (1”) 28 4024052224814 4024052225019 4024052225217 4024052225415 4160-15.039 4160-18.039 4160-22.039 4160-28.039 Welded nipple Ø Pipe 15 (1/2”) 20,8 20 (3/4”) 26,3 25 (1”) 33,2 4024052222919 4024052223312 4024052223718 4160-02.043 4160-03.043 4160-04.043 Ø Pipe EAN Article No 12 15 16 18 4024052214211 4024052214617 4024052214914 4024052215218 3831-12.351 3831-15.351 3831-16.351 3831-18.351 Accessories – Conically sealing Compression fitting for copper or precision steel pipe. Connection male thread G 3/4. Brass nickel-plated. With a pipe wall thickness of 0.8-1 mm insert supporting sleeves. Heed pipe manufacturer’s technical advice. Support sleeve for copper or precision steel pipe with a 1 mm wall thickness. Brass. Compression fitting for copper or precision steel pipes. Male thread connection G 3/4. Soft sealed. Nickel-plated brass. Compression fitting for plastic pipes. Male thread connection G 3/4. Nickel plated brass. Ø Pipe L EAN Article No 12 15 16 18 25,0 26,0 26,3 26,8 4024052127016 4024052127917 4024052128419 4024052128815 1300-12.170 1300-15.170 1300-16.170 1300-18.170 Ø Pipe EAN Article No 15 18 4024052515851 4024052516056 1313-15.351 1313-18.351 Ø Pipe EAN Article No 14x2 16x2 17x2 18x2 20x2 4024052134618 4024052134816 4024052134915 4024052135110 4024052135318 1311-14.351 1311-16.351 1311-17.351 1311-18.351 1311-20.351 7 IMI HEIMEIER / Thermostatic heads and Radiator valves / Three-way reversing valve Dimensions flat sealing flat sealing, with T-piece conically sealing SW H D D D D D L2 L4 L1 D H H SW D L3 D D D L L DN D L L1 L2 L3 L4 H SW 15 20 25 G3/4 G1 G1 1/4 62 71 84 25,5 35,5 42,0 50 58 23,5 26,0 31,0 33,5 30 37 47 SW = Spanner opening D L l Threaded nipple R1/2 27,5 R3/4 30,5 R1 33 13,2 14,5 16,8 D l L Soldering nipple 15 18 16 19 18 20 22 23 28 27 12 13 14 17 20 D d L Welding nipple 20,8 35 26,3 40 33,2 45 17 22 28 The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.imi-hydronic.com. 3100-18.483 10.2014