EL-AC Electronic Load AC Electronic Loads are power electronics devices that behave as an AC electrical load. Typical applications are test platforms for Smartgrids, Load Emulation, AC sources, UPS, AC generators, Inverters, and electrical devices (as fuses or circuit breakers). While most electronic loads are dissipative, CINERGIA offers a comprehensive range of DC, AC and AC&DC regenerative electronic loads producing significant energy savings, optimizing the electrical and cooling installation and reducing test costs. FUNCTIONAL DESCRIPTION KEY FEATURES Operation modes: -Constant Current (CC) -Constant Power (CP) 7.5 kVA – 200 kVA -Constant Impedance (CI) -Automatic test from Excel file Three AC channels: -Independent control of each channel, as three single-phase loads -Parallel control of the three channels, as one single-phase load with 3 times the current rating -Independent control of each channel, as a star three-phase load balanced or unbalanced 80% typical energy saving by regenerating to the grid: 11.1 kW 19.1kW 11 1 .1kW Electronic Load η=90% Equipment 100 kW AC 8 kW DC η = 92 % Under Test GRID (EUT ) 92 kW DC AC 92 kW 4 Quadrant Power Supply Regenerative up to 100% rated power Full 4Q: pure capacitive and inductive current Independent configuration per channel: - Fundamental current up to 400Hz - Harmonics up to 780Hz - Phase angle Working (EUT) voltage: 0-480 Vrms, l-l (with neutral) 0-277 Vrms, l-n 10-400Hz AC&DC version available ELAC_2015_v1 CINERGIA Pere IV 29-35, 5è 1ª 08018 BARCELONA www.cinergia.coop cinergia@cinergia.coop T. +34 934 864 358 Caltest Instruments GmbH Kohlmattstrasse 7 Tel: +49(0)7842-99722-00 D-77876 KAPPELRODECK Fax: +49(0)7842-99722-29 info@caltest.de www.caltest.de EL-AC Electronic Load CONCEPTUAL SCHEMATIC Electronic Load AC DC GRID DC AC EQUIPMENT UNDER TEST (EUT) Optional BACK-TO-BACK TOPOLOGY The converter is formed by a grid-side Active Rectifier and an output Inverter sharing a DC-link. The Active Rectifier allows sinusoidal current consumption with low harmonic distortion and unity power factor. The Inverter generates three independent AC currents controlling the amplitude, phase angle and harmonic content by using a digital resonant control algorithm. TECHNICAL DIAGRAM OF EL-AC AC IN (GRID side) AC OUT (EUT side) 3P+ N 3P+ N EMC filter - - EMC filter Current sensor x 3 Voltage sensor x 3 Drivers x DSP 6 Voltage sensor x 2 CAN control Drivers x DSP control 6 Current sensor x 3 Voltage sensor x 3 HMI ELAC_2015_v1 MODBUS/TCP ETHERNET AC Input is connected to the grid (neutral connection or isolation transformer is required) AC Output is connected to the Equipment Under Test (EUT) and can be used as: - Three-phase star load (balanced or unbalanced) - Three independent single-phase loads - One single-phase load (3 times rated current) www.cinergia.coop EL-AC Electronic Load FUNCTIONALITIES Resistive load Pure capacitive load Pure inductive load Harmonics Single-phase rectifier Three-phase rectifier Phase delay Phase delay + harmonics Independent phase control ELAC_2015_v1 In previous oscilloscope captures: AC source under test (yellow), EL currents phase A, B and C (green, magenta, blue) www.cinergia.coop EL-AC Electronic Load USER INTERFACE SOFTWARE FEATURES Local 3.2” Touchscreen panel Windows 7 user interface for remote operation and data acquisition. Local control port: -1 analog input 0-10V -3 analog outputs 0-10V -4 digital inputs -3 relay outputs -1 Emergency stop Note: all inputs/outputs are isolated Communications port: LAN Ethernet with Modbus/TCP protocol. Optional communications: RS485, RS232, CAN, LabView Configuration of harmonics Cooling The power supply is air-cooled internally. ELAC_2015_v1 Mechanical housing The power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation. Options Galvanic Isolation Isolation monitor Isolated analog inputs RS485, RS232, CAN Labview drivers www.cinergia.coop Configuration of disturbances EL-AC Electronic Load RANGE AND SPECIFICATIONS MAGNITUDE VALUE Power Input side (GRID side) AC Voltage Voltage range AC Current Frequency THDi Power Factor 7.5kVA-200kVA Efficiency Overload Output side (EUT side) AC Voltage AC Current (at rated power) (at rated power) Typical at rated power Configurable by user (at rated power) Rated maximum, ch-neutral Frequency Power factor Harmonic 3ch mode, per channel 1ch mode Fundamental current Configurable by user Configurable by user Harmonic content Maximum % Crest factor Modes of operation Constant Current Constant Power Constant Impedance (R,L,C) General Measurements User interface ELAC_2015_v1 Rated Range 0-±100% 0-±100% min.-100% 0-277Vrms (10-100Hz) 0-210Vrms (101-200Hz) 0-150Vrms (201-400Hz) 10-230Arms 30-690Arms 10-400Hz 0-1 (capacitive/inductive) 1st - 15th at 50Hz (except 10,12 & 14) 1st - 13th at 60Hz (except 10&12) 1st at 400Hz 1st - 9th: 100% 11th: 50%, 13th-15th:10% <3 Resolution Ripple <±0.1%† <1% <±0.1% <1% <±0.1% <1% Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage (Vrms) and Current (Irms) Temperatures 3.2” Touchscreen Local Control port: 1 analog input, 3 analog outputs, 4 inputs, 3 relays Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP 10-90% (Absolute maximum, without condensation) 5-35 ºC (Absolute maximum) Forced air Over Current, Over Voltage, Shortcircuit, Overtemperature Humidity Temperature Cooling Protections Standards CE Marking Safety EN-62040-1-2, EN-60950-1 EMC EMC: EN-62040-2 † FS of current measurements is 3 times the rated curent (crest factor) All specifications are subject to change without notice. www.cinergia.coop 3x400Vrms+Neutral+Earth +15% / -20 % 10-290Arms 48-62Hz <3% ≥0.99 0-1 (capacitive/inductive) >92% 125% for 10 min / 150% for 60 s EL-AC Electronic Load EL-AC MODELS REFERENCE RATED kVA kW EL7.5-AC EL10-AC EL15-AC EL20-AC EL30-AC EL40-AC EL50-AC EL60-AC EL80-AC EL100-AC EL120-AC EL160-AC EL200-AC 7.5 10 15 20 30 40 50 60 80 100 120 160 200 6.75 9 13.5 18 27 36 45 54 72 90 108 128 160 RATED CURRENT AC rms / phase AC rms 3ch mode 1ch mode 10A 30A 15A 45A 20A 60A 25A 75A 40A 120A 50A 150A 65A 195A 80A 240A 105A 315A 130A 390A 465A 155A 555A 185A 690A 230A WEIGHT kg DIMENSIONS DxWxH (mm) 100 100 102 105 150 175 185 185 265 290 290 540 550 770x450x1100 All specifications are subject to change without notice. GALVANIC ISOLATION (optional) REFERENCE RECOMMENDED CIRCUIT BREAKER WEIGHT kg DIMENSIONS DxWxH (mm) IT7.5 IT10 IT15 IT20 IT30 IT40 IT50 IT60 IT80 IT100 IT120 IT160 IT200 Type D - 25A Type D - 32A Type D - 50A Type D - 63A Type D - 80A Type D - 100A Type D - 125A Type D - 160A Type D - 200A Type D - 250A Type D - 315A Type D - 400A Type D - 500A 67 94 125 145 174 217 280 381 435 458 514 612 753 Inside the cabinet 595x415x708 (*) 789x490x865 (*) 964x684x1252 (*) 1192x744x1430 (*) (*) The transformer is delivered in a stand-alone cabinet IP23 ELAC_2015_v1 All specifications are subject to change without notice. Caltest Instruments GmbH www.cinergia.coop Kohlmattstrasse 7 Tel: +49(0)7842-99722-00 D-77876 KAPPELRODECK Fax: +49(0)7842-99722-29 info@caltest.de www.caltest.de 880x590x1320 850x900x2000