Copper Tube TO AS 1571L SEAMLESS COPPER TUBE USAGE High and low-pressure applications including: • Air Conditioning • Refrigeration • Mechanical Services BENEFITS • B acked by MM Kembla’s reputation for quality, service and customer care for nearly 100 years. • Manufactured to Australia / New Zealand standard AS/NZ 1571. • MM Kembla have a range of tubes and fittings suitable for the new R410A and CO2 Ozone friendly refrigerant. • Kembla Refrigeration Tube is stocked nationwide for prompt delivery. • Supported by a full range of copper Refrigeration Fittings. FEATURES • S eamless Copper tube. Available in sizes 4.76mm up to and including 104.78mm, in various wall thicknesses. • The internal cleanliness of airconditioning , refrigeration and medical gas tube is critical in order to prevent contamination to the components in the piping system. MM Kembla has a unique manufacturing process and certified laboratory to confirm that the total residue does not exceed 0.038g/m² as specified in AS/NZ 1571. All MM Kembla Refrigeration Tubes are cleaned and capped. • Pink capped tube has been specifically designed to meet the requirements of R410A air conditioning and refrigeration applications. Also identifiable by a continuous ink mark “KEMBLA AUSTRALIA AS/NZS 1571 (diameter) X (wall thickness) HIGH PRESSURE REFRIGERATION TUBE” • Pink capped tube can also be installed for use with R22, R134a and other lower pressure refrigerants • Tube wall thickness will determine which refrigerant is suitable, depending upon temperature range. • The full range of straight lengths and annealed coils are listed overleaf. • Half Hard tube can be bent using bending tools without applying additional heat. INSTALLATION • C opper tubes and fittings can be successfully joined by silver brazing or flaring. • Silver brazing shall be carried out by professional tradespersons using brazing principles and safety procedures in accordance with AS HB40. • The use of 15% silver solder is recommended when brazing tube or fittings for use with R410a or other high pressure refrigerants. A proprietary silver brazing flux shall be used. • R410A has a 60% higher operating pressure than R22 thus requiring a thicker wall copper tube and significantly stronger (R410A) copper fittings. The minimum allowable tube wall thickness shall be 0.81mm. See table over leaf. Technical Bulletin No: D40/13 Copper Tube TO AS 1571 SPECIFICATIONS Actual tube size Safe Working Pressure (kPa) OD OD Wall Nominal Service Temperature (°C) Annealed T Code Form Straight T Code T Code Thickness tube coilsLengths(6m)(5.8m) (inches)(mm)(mm) mass(m) (6m) (kg/6m)50556065 70 75 3/16” 4.76 0.71 1/4” 6.35 0.71 6.35 0.81 6.35 0.91 5/16” 7.94 0.81 7.94 0.91 3/8” 9.52 0.71 9.52 0.81 9.52 0.91 1/2” 12.70 0.71 12.70 0.81 12.70 0.91 5/8” 15.88 0.81 15.88 0.91 15.88 1.02 3/4” 19.05 0.91 19.05 1.02 19.05 1.14 7/8” 22.22 0.91 22.22 1.22 22.22 1.40 22.22 1.63 1” 25.40 0.91 25.40 1.22 25.40 1.63 1/8” 28.58 0.91 28.58 1.22 28.58 1.63 28.58 1.83 1 1/4” 31.75 0.91 31.75 1.22 31.75 2.03 1 3/8” 34.92 0.91 34.92 1.22 34.92 2.03 1 1/2” 38.10 1.22 38.10 2.29 1 5/8” 41.28 0.91 41.28 1.22 41.28 2.41 2” 50.80 1.22 2 1/8” 53.98 0.91 53.98 1.22 53.98 1.63 2 5/8” 66.68 1.22 66.68 1.63 66.68 2.03 3” 76.20 1.63 4” 101.601.63 4 1/8”104.782.79 0.48 12715122801184511410 10980 10545 30 T32263 0.68 9175886085508235 7920 7610 15 T59423 0.76 1063510270 9910 9545 9180 8820 30 T74634 3T51435 0.83 12140117301131510900 10485 10070 30 T32336 3T92029 0.97 8290800577257440 7160 6875 30 T32522 1.08 9430911087908465 8145 7820 30 T32522 1.05 5900570054955295 5095 4895 15 T32780 1.19 6800657063356105 5870 5640 18 T55743 3 T77112T77111 1.32 7720745571906930 6665 6400 18 T32662 3T56847 1.44 4345419540503900 3750 3605 15 T33007 1.62 4995482546554480 4310 4140 18 T54133 ✓ 3 3 ✓ T10287T10286 1.81 5655546052705075 4880 4685 18 T32930 ✓ 3 3 ✓T22527 2.06 3945381036753540 3405 3270 15 T52078 2.30 4460431041554000 3850 3700 18 T33090 3 3 T24937T24938 2.56 5030486046904515 4345 4170 18 T16850 ✓ 3 3 ✓ T16870T16871 2.78 3600347533553230 3110 2985 15 T33296 ✓ 3 3 ✓ T88072T88073 3.10 4150401038703725 3585 3445 3 3T24813 3.44 4670451043504190 4030 3870 18 T16857 3 T16855T16856 3.27 3140303029252815 2710 2600 18 T76198 ✓ 3 3 ✓ T13862T13864 4.32 4265412039703830 3680 3535 3T64173 4.91 4930476045954425 4255 4090 3T16860 5.66 5795560054005205 5005 4805 3T23515 3.76 2730264025452450 2360 2265 3 T60658T60659 4.97 3705358034503325 3200 3070 3 T91952T91953 6.53 5025485546854510 4340 4170 3 T79850T798461 4.25 2420233522552170 2090 2005 3 T73971T73973 5.63 3275316530502940 2830 2715 3 T91961T91963 7.41 4435428541353980 3830 3680 3T14559 8.25 5015484546704500 4330 4160 3 T14569T14570 4.73 2170209520251950 1875 1800 3 T22039T22040 6.28 2935283527352635 2535 2435 3T91979 10.17 5005483546654495 4325 4150 3T21820 5.22 1970190018351770 1700 1635 3 T15237T15239 6.93 2660257024802390 2300 2210 3 T91987T91989 11.26 4525437042204065 3910 3755 3 T75980T75981 7.59 2435235022652185 2100 2020 3 T91995T91996 13.83 4690453043704210 4050 3890 3 6.19 1660160515451490 1435 1375 3 T32921T32923 8.24 2240216520902010 1935 1860 3 T91791T91793 15.79 4550439042354080 3925 3770 3 T16865T16866 10.20 1810175016901625 1565 1500 3T94943 8.14 1265122011751135 1090 1050 3 T78166T78167 10.85 1705164515851530 1470 1410 3 T94960T94961 14.39 2290221521352055 1980 1900 3T94951 13.46 1375132512801230 1185 1140 3 T31976T31978 17.88 1845178017201655 1595 1530 3T75566 22.13 2310223021502075 1995 1915 3T68980 20.49 1610155515001445 1390 1335 3T88013 27.47 1200116011201080 1035 995 3 T20923T20924 47.98 2015194518751805 1740 1670 3 R410A High Pressure compatible 3 3 Half hard Temper 3 Hard Temper For further information: Refer to the current edition of The Plumbers Handbook available through your MM Kembla representative or contact Customer Service on 1800 804 631. MM Kembla, ABN 13 003 762 641 Gloucester Boulevarde, PO BOX 21, Port Kembla, NSW 2505 T: 1800 804 631 F: 1800 817 846 E: tubesales@kembla.com.au www.kembla.com.au Technical Bulletin No: D40/13