KAW2300 100 WATTS PEP 100 MHz - 1000 MHz The Model KAW2300 is a Class AB wideband RF power amplifier system delivering up to 100 Watts PEP Peak Envelope power over the frequency range of 100 MHz to 1000 MHz. DESCRIPTION TECHNICAL SPECIFICATIONS Operation Frequency: 100-1000 MHz (large range is possible) Output Power (P1dB): 1 00 W a. Min power at 1.3:1 VSWR load: 100W (min) b. Min power at 2:1 VSWR load: 89.1W (-0.5 dB) Flatness: ±0.5 dB over freq. range a. The output power will never decrease below 100 W for -5 dBm input b. At all temperature range (as specified section 44) (Above 45C power output may fall by up to 1 dB) Linearity: Linear up to 10 dB below 1dB c.p. Operation Mode: AB Linear Input Impedance: 50 Ohm Input Connector: N-TYPE female Input Power Level: -5 dBm Nominal for 1dB c.p. (Preferred -10dBm if possible) Input Power Level Protection: 10 dBm (max) at all frequency band Gain: 55 dB (min) Front Panel Gain control: 20 dB (min) Output Impedance: 50 Ohm Output Connector: N-TYPE female Output Test Port: -60 dBc (Nominal) Noise Figure: 20 dB (max) Forward power control: a. 20dB range b. Down to noise with input RF power reduction Harmonics: - 20 dBc @ 100 W (min) Spurious and Hum: -60 dBc (min) Input Signals: CW, FM, AM, PM, Pulse Modulation ar modular rf RESPONSE COMMENTS Compliant Compliant 100W is PEP Peak Envelope Power for all modulations Compliant Compliant Compliant Compliant Compliant Compliant Rear panel -5 dBm Input Level supported Compliant Compliant Compliant Compliant Compliant Compliant Compliant Compliant Non-Compliant Compliant Compliant Rear Panel "N" Connector Rear Panel -13 dBc for 1st Harmonic- all others at or below -20 dBc AM Limited to 100W PEP – 85% DOM = PAR 5.3 dB or 29.5W Unmodulated CW 21222 30th Dr SE, Suite 200 • Bothell, Washington 98021 • 425-485-9000 • Fax 425-486-9657 • www.arworld.us DESCRIPTION TECHNICAL SPECIFICATIONS AM Distortion: 10 % at 85 % D.O.M Interconnected Cables: Must be shielded RESPONSE Compliant Compliant Noise Quieting: 3 Optional modes a. Normal Mode: Amplifier will transmit with no time delay with respect to input signal per specifications b. Automatic Mode: The noise will not be greater than 25dB above KTB when input signal is less than -15 dBm and will operate as specified when signal is greater than -15 dBm, transition time is 20 µsec (max). c. Remote Control: Remote contact closure to ground will reduce noise level to less than 25 dB over KTB PROTECTIONS Output Load: Protected from shorted or disconnected load Input Signal Level: Protected from high level input signal (up to + 15 dBb) Input Signal Frequency: Protected from out of upper limit of band input signals Thermal Overload: Protection 60ºC at PA Enclosure, 80C Internal Power Supply: Protection from overvoltage and under voltage and Over current Power Supply: In case of power line interrupt the amplifier will return to its last state (with no need of external reset) POWER SUPPLY Operating Power: Power Supply Unit AC Power 220 V 50 Hz Contact Breakers: a. AC contact breaker b. DC contact breaker MONITOR, CONTROL, and ENVIRONMENTAL Specifications Remote Control: Full remote control of all the device functions Remote Control Interface: TCP/IP over RJ-45 Ethernet, with multiple user access and control (Multi Server) Remote Control Protocol: propriety or other protocol over TCP is to be suggested by the contractor – accompanied by detailed Protocol manual documentation. Compliant Wake-Up Mode: The converter must wake up in the last operation mode Front Panel Display: Forward power, Reflected Compliant ar modular rf COMMENTS Single chassis, no interconnect cables needed b. RF Level Detector Assy will provide blanking signal at -15 dBm. Fast Blanking time is supported. c. Rear panel BNC connector for Aux. Blanking Input by Remote Control. Compliant Compliant ALC will provide protection Compliant 1 GHz Low-Pass filter at Amplifier input Compliant Compliant Compliant Compliant a. AC Breaker 7A 2-Pole b. DC Breaker 40A Compliant Compliant Compliant Compliant 21222 30th Dr SE, Suite 200 • Bothell, Washington 98021 • 425-485-9000 • Fax 425-486-9657 • www.arworld.us DESCRIPTION TECHNICAL SPECIFICATIONS power, Thermal fault Dimensions: Fit to Rack 19" Warranty: 3 Years STD Final Testing: Final acceptance tests for all units will take place at manufacturer site, with presence of customer representatives (2 persons) – duration – 3 days. Maintenance Training: The proposal shall include an option for a maintenance training course for 2 persons at manufacturer site or at customers. Manual: Will include drawings (electrical and mechanical) up to component level of all circuits. Operating and service manual, part list of all units including RF units and power supplies Technical Support: Must have technical support in Israel – option to repair devices in country. ENVIRONMENT AND QUALITY Environment Operation Humidity: 100 % (non condensing air humidity, not water proof.) Operating Temperature Range: -100 C to 600 C (in wind situation) ALTITUDE: 10000 Feet Weight: 60 lbs ( max ) SHOCK: MIL-STD-810C METHODE 516.2 Procedural 15G 11ms 1/2 SIN VIBRATION: MIL-STD-810C METHODE 514.2 Procedural 7 curves 5, 1 HR PER AXIS VIBRATION: MIL-STD-810C METHODE 514.2 Procedural 7 curves 5 QUALITY ASSURANCE: MIL-STD-9858A or ISO9001 Radiated Emission: Meets MILD-STD-462, RE102 notice 3 In compliance with MIL 461 notices 4, table 8 Conducted RFI: Meets FCC part 15 subpart J.CLASS A Susceptibility: MIL STD 461E a. RS101: Radiated Susceptibility, Magnetic Field, 30Hz to 100 KHz b. RS103: Radiated Susceptibility, Electric Field 2MHz to 40 GHz c. RS105: Radiated Susceptibility, Transient Electromagnetic Field ar modular rf RESPONSE COMMENTS Compliant Compliant Compliant Compliant Compliant 2-Day Training at AR Modular RF (ARM) site quoted, itinerary pending, schedule TBD Provided for assemblies manufactured by ARM only Compliant Compliant Designed for Compliance, not tested Compliant Designed for Compliance, not tested Designed for Compliance, not tested Compliant Compliant Designed for Compliance, not tested Compliant Will test 1st article only Compliant Will test 1st article only Compliant Compliant Designed for Compliance, not tested Compliant Designed for Compliance, not tested Compliant Designed for Compliance, not tested 21222 30th Dr SE, Suite 200 • Bothell, Washington 98021 • 425-485-9000 • Fax 425-486-9657 • www.arworld.us TESTING Production Tests: The manufacturer must perform all tests mentioned in sections 1 – 5 on first unit and 1 – 4 on all other units and deliver the result to the customer 3 weeks before the final testing at the manufacturer site. Final Testing: In the final testing the customer will test all the technical and protection specifications mentioned in section 1 – 5 at the manufacturer site with the manufacturer representative. Non-Compliant Non-Compliant ARM will perform tests in sections 1 – 4 and Section 5 Environmental Vibration tests only on first unit, and will perform only Test Section 1 on all other units. ARM will deliver the result to the customer 3 weeks before the final testing at the manufacturer site. ARM will perform tests in sections 1 – 4 and Section 5 Environmental Vibration tests only on first unit. ARM will perform only Test Section 1 on all other units using ARM automated test system. DOC # 7-98-949-001 REV 21 September 2011 ar modular rf 21222 30th Dr SE, Suite 200 • Bothell, Washington 98021 • 425-485-9000 • Fax 425-486-9657 • www.arworld.us