FIRE ALARM EQUIPMENT Chime/Strobe 2457CS Series FEATURES > Low current draw synchronous strobe The Edwards 2457CS series is an audible/visual signal designed for > Control modules not required that is often preferred over the harsh noise of bells and horns. It is > Red or white flame resistant housing often used in low ambient noise areas. > Strobe available in 15, 30, 15/75, and 110 candela models all units operate at the same time and at a rate of one flash per second. > Chime may be pulsed up to 6 times per second The 2457CS is designed for indoor wall or ceiling mounting. For flush mounting use a 4" (102mm) square box with a depth of 2 1/8" > Engineered thermoplastic housing UL flame rated 94V-0 (54mm). AGENCY APPROVALS for installations that operate in conjunction with an installed fire > Strobe - UL 1971 Listed for the hearing impaired alarm panel and detection devices. > Strobe - UL 1638 Listed for Private Mode Signaling > Chime - UL 464 Listed for Private Mode Signaling use with life safety control equipment. The chime has a gentle tone The strobes employ a unique microprocessor design that assures The 2457CS chime/strobe is an audible/visual signaling appliance ACCESSORIES Cat. No. Description 2459-SMB-R 2459-SMB-W Surface mount box, red Surface mount box, white 12-46 D-04 > CSFM Listed 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards FIRE ALARM EQUIPMENT TECHNICAL INFORMATION 5 1/2" (140mm) 5 1/2" (140mm) 5/8" (16mm) Catalog Number 2457CS-15-(†) Operating Voltage 2457CS-15/75-(†) 2457CS-110-(†) Chime: 20 to 24V DC Continuous or Pulsed up to 6 times per second Strobe: 20 to 31V DC Continuous Chime Current 4,1 Chime Output 2457CS-30-(†) 12 mA @ 24V DC / 12mA @ 24V DC FWR 886 Hz (+/- 70 Hz) Anechoic: 91 dBA Peak @ 24V DC Reverberant: 70 dBA @ 24V DC, 64 dBA at minimum volume @ 20 to 24V DC UL 1638 Strobe Flash Output Not UL 1638 Rated 30 cd 75 cd 110 cd UL 1971 Strobe Flash Output 15 cd (Wall Mount Only) 30 cd Wall 15 cd Ceiling 15 cd Wall 15 cd Ceiling 110 cd Wall 60 cd Ceiling Mean Operating Current 1, 2 70 mA @ 24V DC 83 mA @ 20V DC 89 mA @ 24V DC 107 mA @ 20V DC 96 mA @ 24V DC 115 mA @ 20V DC 197 mA @ 24V DC 241 mA @ 20V DC Peak Operating Current 2 156 mA @ 24V DC 189 mA @ 24V DC 204 mA @ 24V DC 338 mA @ 24V DC Average Operating Current FWR 3 58 mA @ 24V DC 69 mA @ 20V DC 75 mA @ 24V DC 91 mA @ 20V DC 79 mA @ 24V DC 97 mA @ 20V DC 338 mA @ 24V DC 202 mA @ 20V DC Peak Operating Current FWR 3 356 mA @ 24V DC 402 mA @ 24V DC 446 mA @ 24V DC 788 mA @ 24V DC Operating Environment Strobe Flash Rate Synchronization Modules Strobe Lens Wire Connection Lens Markings Faceplate Material 85% relative humidity at 86°F (30°C); 32°F to 120°F (0° to 49°C) variable ambient temperature, indoor Synchronized at one flash per second. External control module necessary to meet UL 1971 synchronization requirements of 10 milliseconds over a two-hour period. EG1M, EG1-RM Clear Lexan Terminals, Polarized Input, #12 AWG Red "FIRE" Vertical Both Sides (Wall Mount) Textured Color-Impregnated Noryl (Exceeds 94V-0 UL Flammability Rating) 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 12-47 © Copyright 2004 Edwards D-04 † Insert "R" for Red or "W" for white. Note 1: Use the mean current rating to establish the maximum number of strobes, wire gauge and standby power requirements. 2400 Series uses 24V DC. Fire Shield uses 24V DC FWR. Note 2: From a FILTERED DC source. Note 3: From an UNFILTERED (Full Wave Rectified) DC source. Note 4: When chime and strobe are connected in parallel to the same circuit the currents for each must be added together.