GT5Y Miniature Electronic Timers Four Selectable Time Ranges Delayed Output 4PDT/3A or DPDT/5A • Three operation modes: ON Delay, Interval ON, and Cycle • Repeat error: ±0.2% maximum • Miniature size • LED indicators for output and power • Complies with safety standards. UL/c-UL listed. EN compliant. 220V AC/ 30V DC, 5A ON Delay 4PDT DPDT Interval ON 220V AC/ 30V DC, 3A 220V AC/ 30V DC, 5A 4PDT 220V AC/ 30V DC, 3A DPDT 220V AC/ 30V DC, 5A 4PDT 220V AC/ 30V DC, 3A Cycle 1S/10S/1M/10M 1S/10S/1M/10M Operating Voltage Type No. 100 to 120V AC 12V DC 24V DC 100 to 120V AC 24V DC GT5Y-2SN1A100 GT5Y-2SN3A100 GT5Y-2SN6A100 GT5Y-2SN1A200 GT5Y-2SN3A200 GT5Y-2SN6A200 GT5Y-2SN1D12 GT5Y-2SN3D12 GT5Y-2SN6D12 GT5Y-2SN1D24 GT5Y-2SN3D24 GT5Y-2SN6D24 GT5Y-4SN1A100 GT5Y-4SN3A100 GT5Y-4SN6A100 GT5Y-4SN1A200 GT5Y-4SN3A200 GT5Y-4SN6A200 GT5Y-4SN3D12 GT5Y-4SN1D24 GT5Y-4SN3D24 GT5Y-4SN6D24 GT5Y-2SV1A100 GT5Y-2SV1D12 GT5Y-2SV1D24 GT5Y-4SV1A100 GT5Y-4SV1D24 100 to 120V AC GT5Y-2SF1A100 200 to 240V AC 24V DC GT5Y-4SF1A200 GT5Y-4SF1D24 100 to 120V AC 200 to 240V AC 12V DC 24V DC 100 to 120V AC 200 to 240V AC 12V DC 24V DC Note: S and M of the time range indicate second, and minute respectively. Accessories Both SY4S-05C and SM2S-05C are UL recognized, CSA certified, and TÜV approved. Others are UL recognized and CSA certified, except for SY4S-05A and SM2S-05A. When ordering, specify the ordering Type No. Item DIN Rail Mount Socket Type No. Socket Hold-Down Spring Panel/ PC Board Mount Socket Socket Hold-Down Spring SY4S-05A SY4S-05C SY4S-05D SY4S-05DF SM2S-05A SM2S-05C SM2S-05D SM2S-05DF SFA-202 SFA-511 SY4S-51 SY4S-61 SM2S-51 SM2S-61 SFA-302 Ordering Type No. SY4S-05A SY4S-05C SY4S-05D SY4S-05DF SM2S-05A SM2S-05C SM2S-05D SM2S-05DF SFA202PN20 SFA511PN20 SY4S-51 SY4S-61 SM2S-51 SM2S-61 SFA302PN20 Package Quantity 1 1 1 1 1 1 1 1 10 sets (20 pcs) 20 1 1 1 1 10 sets (20 pcs) Remarks For 4PDT contact For 4PDT contact For 4PDT contact For 4PDT contact For DPDT contact For DPDT contact For DPDT contact For DPDT contact For SY4S-05A, SM2S-05A (2 pcs/set) For SY4S-05D, SY4S-05DF, SM2S-05D, SM2S-05DF For 4DPT contact, Solder Terminal For 4DPT contact, PC Board Terminal For DPDT contact, Solder Terminal For DPDT contact, PC Board Terminal For SY4S-51, SY4S-61, SM2S-51, SM2S-61 (2 pcs/set) Code Scale 1S 10S 1M 10M 3S 30S 3M 30M 6S 60S 6M 60M 0 to 10 0 to 10 0 to 10 0 to 10 0 to 3 0 to 3 0 to 3 0 to 3 0 to 6 0 to 6 0 to 6 0 to 6 Time Range Indication × 0.1 S ×1 S × 0.1 M ×1 M ×1 S × 10 S ×1 M × 10 M ×1 S × 10 S ×1 M × 10 M Time Range 0.1 sec to 1 sec 0.2 sec to 10 sec 1.2 sec to 1 min 12 sec to 10 min 0.1 sec to 3 sec 0.5 sec to 30 sec 3 sec to 3 min 30 sec to 30 min 0.1 sec to 6 sec 1 sec to 60 sec 6 sec to 6 min 1 min to 60 min Contact Ratings Type No. Contact Configuration GT5Y-4 GT5Y-2 4PDT DPDT Resistive Load 220V AC, 3A 30V DC, 3A 220V AC, 5A 30V DC, 5A Inductive Load cosø=0.3 L/R=7ms 220V AC, 0.8A 30V DC, 1.5A 220V AC, 2A 30V DC, 2.5A 250V AC/125V DC 250V AC/125V DC 3A 5A (Note) Maximum Switching Voltage Maximum Switching Current Maximum Switching Frequency 1800 operations/hour 1800 operations/hour Resistive Load AC: 660VA DC: 90W AC: 1100VA DC: 150W Inductive Load cosø= 0.3 L/R=7ms AC: 176VA DC: 45W AC: 440VA DC: 75W 5V DC, 10mA (reference value) 24V DC, 5mA (reference value) 5V DC, 20mA (reference value) 24V DC, 10mA (reference value) Minimum Applicable Load External Protection Element Electrical Mechanical Fuse 250V 3A Fuse 250V 5A 200,000 operations minimum (220V AC, 3A) 50 million operations minimum 500,000 operations minimum (220V AC, 5A) 50 million operations minimum Note: See Operating Temperature - Maximum Switching Current Characteristics. Operating Temperature Maximum Switching Current Characteristics Check the derating curve described below when mounting more than two GT5Y-2 timers and SM2S05∗ sockets. Mounting Direction Derating Curve Switching Current DPDT Output Rated Load Contact Time Ranges Allowable Contact Power Operation Mode Package Quantity: 1 Time Ranges (4 ranges selectable) 1S/10S/1M/10M 3S/30S/3M/30M 6S/60S/6M/60M 1S/10S/1M/10M 3S/30S/3M/30M 6S/60S/6M/60M 1S/10S/1M/10M 3S/30S/3M/30M 6S/60S/6M/60M 1S/10S/1M/10M 3S/30S/3M/30M 6S/60S/6M/60M 1S/10S/1M/10M 3S/30S/3M/30M 6S/60S/6M/60M 1S/10S/1M/10M 3S/30S/3M/30M 6S/60S/6M/60M 3S/30S/3M/30M 1S/10S/1M/10M 3S/30S/3M/30M 6S/60S/6M/60M Life Type List SM2S-05A, C Sockets 5A SM2S-05D, DF Sockets 2.5A 40ºC 50ºC Operating Temperature 1086 GT5Y Miniature Electronic Timers General Specifications Type Operation Type Pollution Degree Overvoltage Category A200 Rated A100 Operational D24 Voltage D12 A200 A100 Voltage Range D24 D12 Reset Voltage Operating Temperature Storage/Transportation Temperature Operating Humidity Operation Charts and Internal Connections GT5Y-oSN GT5Y-oSV GT5Y-oSF ON Delay Interval Cycle 2 (IEC60664-1) III (IEC60664-1) 200 to 240V AC (50/60Hz) 100 to 120V AC (50/60Hz) 24V DC 12V DC 170 to 264V AC (50/60Hz) 85 to 132V AC (50/60Hz) 21.6 to 26.4V DC 10.8 to 13.2V DC Rated Voltage × 20% minimum -10 to +50°C (no freezing and condensation) 35 to 85% RH (no condensation) 0 to 2000m (operation) 0 to 3000m (transportation) 100 ms maximum ±0.2%, ±20 ms maximum ±0.5%, ±20 ms maximum ±3% maximum ±10% maximum 100 MΩ minimum (500V DC megger) Between power and output terminals: 2000V AC, 1 minute Between contacts of different poles: 2000V AC, 1 minute Between contacts of the same pole: 1000V AC, 1 minute 10 to 55 Hz, amplitude 0.75 mm, 2 hours each in 3 directions Operating extremes: 98 m/s2, Damage limits: 490 m/s2, 3 shocks each in 6 directions IP40 (timer), IP20 (socket) (IEC60529) 1.6 VA (200V AC/60Hz) 1.4 VA (100V AC/60Hz) 1.0W 0.9W 27.5H × 21.0W × 58.6D mm 50g Reset Time Repeat Error Voltage Error Temperature Error Setting Error Insulation Resistance Dielectric Strength Vibration Resistance Shock Resistance Degree of Protection A200 Power A100 Consumption D24 (approx.) D12 Dimensions Weight (approx.) Note: See Operating Temperature – Maximum Switching Current Characteristics. • Electrical Life Curves 5000 AC Load Life (× 10,000 operations) Life (× 10,000 operations) 1000 110V AC Resis. Load 220V AC Resis. Load 110V AC Induc. Load 220V AC Induc. Load 100 50 10 0 1 2 Operation Display Lights 1-9, 3-11, 2-10, 4-12 (NC) ON Delay 5-9, 7-11, 6-10, 8-12 (NO) Display Units POWER Indicator Safety Products OUT Indicator 3 4 500 1-9, 3-11, 2-10, 4-12 (NC) Interval ON 0 1 2 3 4 Comm. Terminals 5-9, 7-11, 6-10, 8-12 (NO) POWER Indicator AS-Interface OUT Indicator Relays & Timers Set Time T T Terminal No. 13-14 (POWER) Sockets 1-9, 3-11, 2-10, 4-12 (NC) Cycle 5-9, 7-11, 6-10, 8-12 (NO) Circuit Protectors POWER Indicator Power Supplies OUT Indicator (Internal Connections) • GT5Y-4 • GT5Y-4 PLCs & SmartRelay Operator Interfaces 50 10 5 Terminal Blocks 100 Sensors Control Stations GT5Y-2 5 Load Current (A) Load Current (A) Set Time Terminal No. 13-14 (POWER) 30V DC Resis. Load 30V DC Induc. Load 100V DC Resis. Load 100V DC Induc. Load 1000 See page 1112 for SM2S-05A, SM2S-05C, SM2S-05D, SM2S-05DF. Dimensions (When using DIN Rail Mount Socket) Explosion Protection (When using DIN rail) BAA, BAP: 87.6 max. (Note 4) • GT5Y-4 See page 1113 for SY4S-05A, SY4S-05C, SY4S-05D, SY4S-05DF. 83.6 max. (Note 3) References (When using DIN rail) BAA, BAP: 87.6 max. (Note 2) 27.5 83.6 max. (Note 1) 6 52.6 58.6 6.4 HoldDown Spring DIN Rail 18.5 21 6 52.6 58.6 6.4 25 DIN Rail 3 18.5 25 3 27.5 21 HoldDown Spring Flush Silhouette Control Units Set Time Terminal No. 13-14 (POWER) DC Load GT5Y-2 GT5Y-4 GT5Y-2 GT5Y-4 500 Item -30 to +80°C (no freezing and condensation) Altitude 5000 Operation Mode Note 3: SM2S-05A: 83.6 max., SM2S-05C: 83.6 max., SM2S-05D: 88.6 max., SM2S-05DF: 88.6 max. Note 4: SM2S-05A: 87.8 max., SM2S-05C: 87.8 max., SM2S-05DN: 92.8 max., SY4S-05DF: 92.8 max. Note 1: SY4S-05A: 83.6 max., SY4S-05C: 83.6 max., SY4S-05D: 88.6 max., SY4S-05DF: 88.6 max. Note 2: SY4S-05A: 87.8 max., SY4S-05C: 87.8 max., SY4S-05D: 92.8 max., SY4S-05DF: 92.8 max. 1087 GT5P Miniature Electronic Timers Economic Efficiency Focused Delayed Output SPDT/5A • Three operation modes: ON Delay, Cycle, and One Shot • Repeat error: ±0.2% maximum • Complies with safety standards UL recognized, CSA certified, TÜV approved, EN compliant ON Delay Cycle One Shot Contact SPDT SPDT SPDT Package Quantity: 1 Output 24V DC/ 120V AC, 5A 240V AC, 3A 24V DC/ 120V AC, 5A 240V AC, 3A 24V DC/ 120V AC, 5A 240V AC, 3A Time Range 3S 10S 30S 60S 3M 6M 10M 1S 6S 10S 30S 60S 3M 6M 10M 1S 6S 10S 60S 6M 10M 10S 30S 60S 10M 3S 10S 3S 10S 3S 10S 3S 10S 3S 3S 10S 3S 10S Operating Voltage 100 to 120V AC 200 to 240V AC 24V AC/DC 12V DC 100 to 120V AC 200 to 240V AC 24V AC/DC 12V DC 100 to 120V AC 200 to 240V AC 24V AC/DC Type No. (Order No.) GT5P-N3SA100 GT5P-N10SA100 GT5P-N30SA100 GT5P-N60SA100 GT5P-N3MA100 GT5P-N6MA100 GT5P-N10MA100 GT5P-N1SA200 GT5P-N6SA200 GT5P-N10SA200 GT5P-N30SA200 GT5P-N60SA200 GT5P-N3MA200 GT5P-N6MA200 GT5P-N10MA200 GT5P-N1SAD24 GT5P-N6SAD24 GT5P-N10SAD24 GT5P-N60SAD24 GT5P-N6MAD24 GT5P-N10MAD24 GT5P-N10SD12 GT5P-N30SD12 GT5P-N60SD12 GT5P-N10MD12 GT5P-F3SA100 GT5P-F10SA100 GT5P-F3SA200 GT5P-F10SA200 GT5P-F3SAD24 GT5P-F10SAD24 GT5P-F3SD12 GT5P-F10SD12 GT5P-P3SA100 GT5P-P3SA200 GT5P-P10SA200 GT5P-P3SAD24 GT5P-P10SAD24 Time Ranges Code 1S 3S 6S 10S 30S 60S 3M 6M 10M Time Range 0.1 sec to 1 sec 0.1 sec to 3 sec 0.1 sec to 6 sec 0.2 sec to 10 sec 0.5 sec to 30 sec 1 sec to 60 sec 3 sec to 3 min 6 sec to 6 min 10 sec to 10 min Contact Ratings Contact Configuration Maximum Switching Voltage Maximum Switching Current Maximum Switching Power SPDT Rated Load Operation Mode 120V AC / 24V DC, 5A 240V AC, 3A Life Type No. Resistive Load Inductive Load cosø = 0.3 - 0.4 L/R = 15 ms Electrical Mechanical 250V AC, 150V DC 5A AC: 960VA DC: 120W 240V AC, 0.8A 120V AC, 1.4A 24V DC, 1.7A 100,000 operations minimum (rated resistive load) 20,000,000 operations minimum Minimum Applicable Load: 5V DC 10 mA (reference value) Note: S and M of time range indicate second and minute respectively. Accessories Item DIN Rail Mount Socket Socket Hold-Down Spring Panel Mount Socket 1088 w/Solder Terminals w/Wire Wrap Terminals Type No. SR2P-06A SR2P-05A SR2P-05C SFA-202 SFA-203 SR2P-511 SR2P-70 Ordering Type No. SR2P-06A SR2P-05A SR2P-05C SFA-202PN20 SFA-203PN20 SR2P-511 SR2P-70 Package Quantity 1 1 1 10 sets (20 pcs) 10 sets (20 pcs) 1 1 Remarks UL/CSA/TÜV For SR2P-06A (2 pcs/set) For SR2P-05A (2 pcs/set) UL/CSA GT5P Miniature Electronic Timers General Specifications Type Operation Type Pollution Degree A200 Rated A100 Operational AD24 Voltage D12 A200 A100 Voltage Range AD24 D12 Operating Temperature Storage/Transportation Temperature Operating Humidity Operation Mode Reset Time Repeat Error Voltage Error Temperature Error Setting Error Insulation Resistance Dielectric Strength Vibration Resistance Shock Resistance A200 A100 AD24 D12 Dimensions Weight (approx.) Operation Set Time Display Lights On Delay 6-8 (NO) Display Units POWER Indicator OUT Indicator Safety Products Set Time T T Terminal No. 2-7 (POWER) Terminal Blocks 5-8 (NC) Comm. Terminals Cycle 6-8 (NO) POWER Indicator AS-Interface OUT Indicator Relays & Timers Terminal No. 13-14 (POWER) 50ms minimum 3-4 (Start Input) One Shot Sockets 5-8 (NC) Circuit Protectors 6-8 (NO) Power Supplies POWER Indicator 100 70 50 OUT Indicator 30 24V DC R 120V 20 240V 10 AC R AC R 7 5 120 24V esis. load esis. esis load . loa d (Internal Connections) ON Delay/Cycle 6 5 7(~)/( + ) PLCs & SmartRelay One Shot 6 5 DC 24 τ= VA 0V 15 Cc ms AC os ø= co sø 0.4 =0 .4 3 2 Flush Silhouette Control Units 5-8 (NC) • Electrical Life Curves Life ( ×10,000 operations) Item Terminal No. 2-7 (POWER) –30 to +70°C (no freezing) 35 to 85% RH (no condensation) 0 to 2000m (operation) 0 to 3000m (transportation) 100 ms maximum ±0.2%, ±10 ms maximum ±0.5%, ±20 ms maximum ±3% maximum ±10% maximum 100 MΩ minimum (500V DC megger) Between power and output terminals: 2000V AC, 1 minute Between contacts of different poles: 2000V AC, 1 minute Between contacts of the same pole: 750V AC, 1 minute 10 to 55Hz, amplitude 0.75 mm, 2 hours each in 3 directions Operating extremes: 98 m/s2, Damage limits: 490 m/s2 3.9 VA (60Hz) 5.6 VA (60Hz) 2.3 VA (60Hz) 2.9 VA (60Hz) 1.3 VA (60Hz)/0.5W 1.2 VA (60Hz)/0.5W 0.6W 0.6W 36H × 29W × 81.5D mm 49g Altitude Power Consumption (approx.) Operation Charts and Internal Connections GT5P-N GT5P-F GT5P-P ON Delay Cycle One Shot 2 (IEC60664-1) 200 to 240V AC (50/60Hz) 100 to 120V AC (50/60Hz) 24V AC (50Hz/60Hz)/24V DC 12V DC 170 to 264V AC (50/60Hz) 85 to 132V AC (50/60Hz) 20.4 to 26.4V AC (50/60Hz)/21.6 to 26.4V DC 10.8 to 13.2V DC –10 to +50°C (no freezing) 7(~)/( + ) 4 Operator Interfaces 3 Sensors 1 0 1 2 3 4 Load Current (A) 5 8 2(~)/(-) 8 2(~)/(-) Control Stations Dimensions (When using DIN Rail Mount Socket) • SR2P-05A For SR2P-05C, see page 1109. Explosion Protection • SR2P-06B References Note 1: SR2P-05C: 99.5 max. Note 2: SR2P-05C: 103.5 max. 1089 GT5Y/GT5P Miniature Electronic Timers [Common] Dimensions / Mounting Hole Layout (for Panel/PC Board Mount Socket) 1. GT5Y-4 • Panel Mount Socket (SY4S-51) 2. GT5Y-2 • Panel Mount Socket (SM2S-51) • PC Board Mount Socket (SY4S-61) • PC Board Mount Socket (SM2S-61) 3. GT5P • Solder Terminal (SR2P-511) • Wire Wrap Terminal (SR2P-70) Installation of Hold-Down Springs • DIN Rail Mount Socket • Panel/PC Board Mount Socket The SFA-302 Hold-Down Springs can be installed to the SY4S-51, SY4S-61, SM2S-51, and SM2S-61 sockets. Hold-down springs cannot be installed to SR2P-511 and SR2P-70 panel mount sockets. Note: Once installed into sockets, the hold-down springs cannot be removed. 1090 GT5Y/GT5P Miniature Electronic Timers [Common] ! Safety Precautions • Be sure to turn off power before mounting, removal, wiring, maintenance and inspection. Otherwise, electric shock or fire could occur. • Be sure to use timers within rated specification values. Otherwise, electric shock or fire may occur. • Be sure to use wires to meet voltage and current requirements and tighten M3.5 terminal screws to a tightening torque of 1.0 to 1.3 N•m. Be sure to solder the terminals correctly. Loose terminal screws or incomplete soldering may cause abnormal heat and fire. Flush Silhouette Control Units Display Lights Instructions Time Range Setting Contact Protection Display Units The time range is calibrated at its maximum time scale, therefore it is desirable to use the timer at a setting as close to its maximum time scale as possible for accurate time delay. For a more accurate time delay, adjust the control knob by measuring the operating time with a watch before application. On the GT5Y timers, a desired time range can be selected using the time range selectors on the side surface. Turn the multiplier and time unit selectors using a flat screwdriver until they click. Switching an inductive load generates a counter-electromotive force in the coil. The counter emf will cause arcing, which may shorten the contact life. Application of a protection circuit is recommended for contact protection. Safety Products Terminal Blocks Rest Time When turning power off after time-out, allow a rest time of 0.1 sec, and during operation, 1 sec at least. Control knob Power Time range indication window Since DC types are designed to operate on DC power containing 10% or less ripple, insert a smoothing circuit when using a rectified AC power to operate DC type timers. Time range selector Continuous Energizing Continuous energizing for a long period of time may damage the electrical characteristics of the timer because of internal heating. Use an additional relay to the output circuit and refrain from continuous energizing of the timer. Comm. Terminals AS-Interface Relays & Timers Sockets Circuit Protectors Dielectric Strength Test Timing Accuracy Timing accuracies are calculated from the following formulas: • Repeat Error =± 1 Max. measured value - Min. measured value × 100 (%) × 2 Maximum scale value • Voltage Error =± Tv - Tr Tv: Average of measured values at voltage V × 100 (%) Tr Tr: Average of measured values at the raged voltage • Temperature Error =± Tt - T20 Tt: Average of measured values at t°C × 100 (%) T20 T20: Average of measured values at 20°C • Setting Error = Average of measured values - Set value × 100 (%) Maximum scale value Use of External Input (GT5P-P Only) 1. Do not apply voltage to external input terminals 3 and 4. Be sure not to connect external inputs to other terminals because the internal circuit may be damaged. 2. Use reliable mechanical contacts capable of switching approximately 22V DC, 1 mA to close input terminals 3 and 4. (Closed: 1 kΩ maximum, Open: 100 kΩ minimum) The input terminals should not be connected to a ground wire of other devices. 3. Do not install input lines in parallel with high-voltage or motor lines. Use shielded wires or separate conduit for input lines, and make the input lines as short as possible. Load Current The rated current of the contact (or control output) should not be exceeded. Especially for inductive, capacitive, and incandescent lamp loads, the inrush current as large as a few to several tens times the rated current may cause welded contacts and other troubles. The amount of inrush current as well as steady-state current must be taken into consideration. When performing an insulation resistance or dielectric strength test on control panels containing timers, make sure that the dielectric strength of the timer is not exceeded. In case the dielectric strength is exceeded, remove the timers from the panels. Power Supplies PLCs & SmartRelay Operating Environment • Temperature and Humidity Use the timer within the operating temperature and operating humidity ranges and prevent freezing and condensation. After storing below the operation temperature, leave the timer at room temperature for a sufficient period of time before use. • Environment Prevent a corrosive gas such as sulfurous or ammonia gas, organic solvents (alcohol, benzine, thinner, etc.), strong alkaline substances or strong acids from touching to the timer, and do not use the timer in such an environment. Keep the timer from water splashes or steam. • Vibration and Shock Since excessive vibrations or shocks cause the output contacts to open, the timer should be used within the operating extremes of vibration and shock resistance. Use of hold-down springs is recommended for secure mounting on sockets. Others • Use a mechanical-contact switch or relay to supply power to the time. • When driving the timer using a solid-state output device such as two-wire proximity switch, photoelectric switch or solid-state relay directly, malfunction may be caused by a leakage current from the solid-state device. Be sure to check thoroughly before using. • Since AC types (such as A100 and A200) comprise a capacitive load, the SSR dielectric strength should be two or more times as large as the power voltage when switching the timer power using an SSR. • To make a sequence circuit by connecting timer and relay, check the timer operation sufficiently in consideration of the reset time of the timer. 1091 Operator Interfaces Sensors Control Stations Explosion Protection References GT5Y/GT5P Miniature Electronic Timers [Common] Installation/Removal of Hold-Down Springs 1092 Installation/Removal of Hold-Down Springs