8 Conductors, 100 Ohms 4 Shielded Twisted Pairs: Conductors: 24

8 Conductors, 100 Ohms
4 Shielded Twisted Pairs:
Conductors: 24 AWG stranded tin plated copper
Insulation: High temperature flouropolymer foam
Binder: Clear Mylar tape
Drain Wire: 24 AWG stranded tin plated copper
Shield: Aluminum/Mylar foil
Physical Characteristics
Outer Diameter: 0.299 inches nominal
Bend Radius: 1.5 inches
Weight: 6.0 lbs/100 ft
Temperature Range: -55° to +200° C
Skew: < 12.8 ns/100 ft BUS
Skydrol Resistant: Yes
Overall Cable:
Shield 1: Aluminum/Mylar foil
Shield 2: 36 AWG stranded tin plated copper
Outer Jacket: White high temperature flouropolymer
(laser markable)
Applications
LVDS RIB Cable, ARINC 646, Ethernet
Color Code:
Pair 1: White/Blue, Blue/White
Pair 2: White/Orange, Orange/White
Pair 3: White/Green, Green/White
Pair 4: White/Brown, Brown/White
Pair 1, Shield: Red
Pair 2, Shield: Blue
Pair 3, Shield: Green
Pair 4, Shield: Gold
Environmental:
• ECS Composite cables are designed to meet, or exceed, burn requirements as set forth in Federal Aviation
Regulations 14 CFR Part 25.869(a)(4) Amdt 25-113, Appendix F Part I(a)(3).
• They are manufactured with materials which, when subjected to flames or high temperatures, will not outgas
deadly hydrogen chloride produced by conventional PVC cables.
Cage Code: 66197 • Issue Date: 9/21/09
ECS-P/N 422408 © 2009 ECS, Inc. All Rights Reserved. Printed in USA.