QO® Load Centers 3Ø, Main Lugs, Main Circuit Breaker Class 1130 / Refer to Catalog 1100CT0501 www.us.schneider-electric.com FOR CURRENT INFORMATION 1 Table 1.22: 3Ø4W 208Y/120 Vac, 3Ø4W 240/120 Vac Delta and 3Ø3W 240 Vac Delta, UL Listed. (Order QO, QO-GFI, QO-AFI, QO-PL branch circuit breakers from pages 1-2 and 1-3.) Mains Rating LOAD CENTERS I N D O O R Max. Number of 1P QO circuit breakers $ Price (Interior, Box and Cover) Indoor Cover with Door (Order Separately) Load Center Box and Interior Cat. No. Flush Cat. No. $ Price Surface Cat. No. Main Wire Size AWG/kcmil $ Price Fixed Mains—Factory-installed Main Lugs—Copper Bus—65 kA Short Circuit Current Rating a 60 A 3 71.00 QO403L60NF/S 71.00 Cover Included With Load Center 12 246.10 QO312L125Gh 221.00 QOC16UF QOC16US 25.10 i 125 A 20 339.10 QO320L125Gh 314.00 QOC24UF QOC24US 25.10 i 24 385.10 QO324L125Gh 360.00 QOC24UF QOC24US 25.10 i 18 353.00 QO318L200Gh 295.00 QOC30UF QOC30US 58.00 i 200 A 30 471.00 QO330L200Gh 413.00 QOC30UF QOC30US 58.00 i 225 A 42 635.00 QO342L225Gh 561.00 QOC42UF QOC42US 74.00 i Equipment Ground Bar Kit (Order Separately) Box No. See Pages 1-16, 1-17 $ Pricej Al Cu Cat. No. — 10–6 6–2/0 6–2/0 PK4GTA Factory-incl.g Factory-incl.g Factory-incl.g Factory-incl.f Factory-incl.f Factory-incl.f 7.20 — — — — — — 13 6 7 7 9 9 11 PK15GTA PK18GTA PK18GTA PK23GTA PK18GTA PK23GTA PK23GTA 11.40 12.50 12.50 14.20 12.50 14.20 14.20 9 12 12 12 12 12 12 6–250 6–250 6–300 Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25 kA Short Circuit Current Rating b 100 A 27 705.00 QO327M100c 647.00 QOC30UF QOC30US 58.00 i 4–2/0 125 A 30 1287.00 QO330MQ125dh 1226.00 QOC342MQF QOC342MQS 61.00 4–300 30 1287.00 QO330MQ150dh 1226.00 QOC342MQF QOC342MQS 61.00 150 A 4–300 42 1412.00 QO342MQ150dh 1351.00 QOC342MQF QOC342MQS 61.00 30 1287.00 QO330MQ200dh 1226.00 QOC342MQF QOC342MQS 61.00 200 A 4–300 42 1412.00 QO342MQ200dh 1351.00 QOC342MQF QOC342MQS 61.00 225 A 42 1412.00 QO342MQ225dh 1351.00 QOC342MQF QOC342MQS 61.00 4–300 6–300 4–2/0 4–300 4–300 4–300 4–300 Fixed Mains—Factory-installed Main Lugs—Copper Bus—65 kA Short Circuit Current Ratingae 60 A 3 118.00 QO403L60NRB 118.00 — 10–6 PK4GTA 7.20 10R 12 323.00 QO312L125GRB 323.00 Factory Incl.g — 3R 125 A 6–2/0 6–2/0 20 419.00 QO320L125GRB 419.00 Factory Incl.g — 4R R Cover Included 18 412.00 QO318L200GRB 412.00 Factory Incl.f — 6R A 200 A 6–250 6–250 I 30 559.00 QO330L200GRB 559.00 Factory Incl.f — 6R N 225 A 42 996.00 QO342L225GRB 996.00 6–300 6–300 Factory Incl.f — 8R P R Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25 kA Short Circuit Current Ratingb e O 100 A 27 790.00 QO327M100RBc 790.00 4–2/0 4–2/0 PK15GTA 11.40 6R O 125 A 30 1431.00 QO330MQ125RBd 1431.00 4–300 4–300 PK18GTA 12.50 14R F 150 A 30 1431.00 QO330MQ150RBd 1431.00 4–300 4–300 PK18GTA 12.50 14R Cover Included 30 1431.00 QO330MQ200RBd 1431.00 PK18GTA 12.50 14R 200 A 4–300 4–300 42 1555.00 QO342MQ200RBd 1555.00 PK23GTA 14.20 14R 225 A 42 1555.00 QO342MQ225RBd 1555.00 4–300 4–300 PK23GTA 14.20 14R Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2. a UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. b 25 kA short circuit current rating maximum with Square D Type QDL main circuit breaker, or 22 kA SCCR maximum with back-fed Type QO-VH main circuit breaker, feeding QO 10 k AIR branch circuit breakers. c Includes factory-installed back fed QO3100VH main circuit breaker. d 65 kA Short Circuit Current Rating maximum with field-installed Square D type QGL 65 k AIR minimum main circuit breaker feeding QO and Q1 10 k AIR minimum branch circuit breakers. e Side hinge door device allow 1-1/4 in. on left side for door to open. f PK23GTA and LK100AN. g PK15GTA. h Certified to IEC 60439-1 for use on 415Y/240 Vac 3Ø4W, 3,000 SCCR when QODX... branch circuit breakers are used and 10,000 SCCR when QO...VS branch circuit breakers are used. CE marked. i DE3A Discount Schedule j DE2 Discount Schedule Table 1.23: 3Ø Main Circuit Breakers Field-installable alternate main circuit breakers for QO 3Ø main circuit breaker load centers rated 70–225 A. Do not exceed the load center main rating. k Amperage 25 k AIR 65 k AIR 100 k AIRk 70 A QDL32070 QGL32070 QJL32070 80 A QDL32080 QGL32080 QJL32080 90 A QDL32090 QGL32090 QJL32090 100 A QDL32100 QGL32100 QJL32100 110 A QDL32110 QGL32110 QJL32110 125 A QDL32125 QGL32125 QJL32125 150 A QDL32150 QGL32150 QJL32150 175 A QDL32175 QGL32175 QJL32175 200 A QDL32200 QGL32200 QJL32200 225 A QDL32225 QGL32225 QJL32225 $ Price (DE2) 1189.00 1628.00 1864.00 When these 3P circuit breakers are used as the main circuit breaker of a 3Ø load center, the maximum AIR rating is 65 kA at 240 Vac and 100 kA at 208 Vac. Table 1.24: 3Ø Main Lug Kits Field-installable main lugs for convertible 3Ø main circuit breaker load centers. QO342MQ200 1-8 QO312L125G Main Lug Amperage Rating 125 A 225 A DE3 DE3A DE2 Cat. No. QOL3125 QOL3225 Discount Schedule $ Price 44.90 105.00 Lug Wire Size AWG/kcmil 6–2/0 Cu/Al 6–300 Cu/Al © 2007 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com QO® Load Centers Special Applications www.us.schneider-electric.com Class 1130 / Refer to Catalog 1100CT0501 FOR CURRENT INFORMATION QO Special Application (Order QO, QOT, QO-EPD, QO-GFI and QO-AFI Branch Circuit Breakers from pages 1-2 and 1-3.) Short Circuit Current Rating Spaces Max. 1P Circuits a Cat. No. 0 2 QO2L30TTSd QO24L50TTSe Manufactured Housing: 1Ø2W 120 Vac—Main Lugs Only—CSA Certified 30 Ac 10 kA 2 2 4 50 A 10 kA 2 I N D O O R Load Center b Box, Interior, and Cover Max. Tandem Circuit Breakers Equipment Ground Bar Kit (Order Separately) $ Price Cat. No. 33.90 52.00 $ Price Factory-installed 1Ø2W 120 Vac—Main Circuit Breaker—CSA Certified 30 A 10 kA 3 5 2 QO35FM30TTF/S 55.00 Factory-installed 1Ø3W 120/240 Vac—Main Lugs Only—CSA Certified 70 A 10 kA 2 4 2 QO24L70TSe 52.00 10 kA 6 12 6 QO612L100TF/Sg 57.00 Factory 10 kA 6 12 6 QO612L100DTF/Sg 67.00 Installed 100 A 10 kA 8 16 8 QO816L100TF/Sg 91.00 10 kA 8 16 8 QO816L100DTF/Sg 106.00 Generator Panel: 1Ø3W 120/240 Vac—Factory-installed Main Circuit Breakers with Mechanical Interlock 30 A 10 kA 4 8 4 QO48M30DSGP 375.00 PK7GTA 7.80 60 A 10 kA 4 8 4 QO48M60DSGP 375.00 PK7GTA 7.80 Generator Panel – Use With Automatic Transfer Switchk—1Ø3W 120/240 Vac—Factory/Field-installed Main Circuit Breaker New! 150 A 22 kA 38 42 42 QO13842MX150 899.00 PK23GTA 14.20 200 A 22 kA 38 42 42 QO13842MX200 999.00 PK23GTA 14.20 22 kA 38 42 42 QO13842MX225 1099.00 PK23GTA 14.20 225 A 22 kA 38 42 42 QO13842UX225m 799.00 PK23GTA 14.20 QOC38MXUF (Cover) 99.00 150 A 22 kA 14 28 28 QO11428MX150FTRBl 899.00 PK23GTA 14.20 22 kA 14 28 28 QO11428MX200FTRBl 999.00 PK23GTA 14.20 200 A 22 kA 14 28 28 QO11428UX200FTRBml 799.00 PK23GTA 14.20 Load Center with Cover: 1Ø3W 120/240 Vac—UL Listed Complete QO Load Center—Box, Interior & Combination Cover in One Package Main Wire Size AWG/kcmil Al Cu Box No. See Page 1-16 12–10 — 14–10 14–6 1 2 f 12–3 LOAD CENTERS Mains Rating 3 14–4 2 4 4 4 4 14–8 8–2 14–8 8–2 4 4 4–250 4–250 4–250 4–250 4–250 4–250 4–250 4–250 12 12 12 12 4–250 4–250 4–250 4–250 4–250 4–250 7R 7R 7R 4–1 1 Table 1.25: Convertible Mains—Factory-Installed Main Lugs hi—QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5)—Copper Bus 65 kA 12 0 QO112L125GC 125.00 PK12GTA Incl. 6–2/0 6 12 125 A 65 kA 12 24 12 QO11224L125GC 166.00 PK15GTA Incl. 6–2/0 6 20 65 kA 20 0 QO120L125GC 189.00 PK15GTA Incl. 6–2/0 7 Convertible Mains—Factory-Installed Main Lugs hi—QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5)—Copper Bus 150 A 65 kA 30 30 0 QO130L150TC 301.00 PK23GTA & LK100AN Installed 6–250 9 200 A 65 kA 30 40 10 QO13040L200GC 383.00 PK23GTA & LK100AN Incl. 6–250 9 Convertible Mains—Factory-Installed Main Circuit Breaker— QOM1 Main Frame Size—Convertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)—Copper Bus j 22 kA 12 12 0 QO112M100C 234.00 PK9GTA 8.90 4–1/0 5 22 kA 12 20 8 QO11220M100C 275.00 PK15GTA 11.40 4–1/0 5 100 A 22 kA 16 16 0 QO116M100C 263.00 PK12GTA 10.50 4–1/0 6 22 kA 20 20 0 QO120M100C 297.00 PK15GTA 11.40 4–1/0 6 Convertible Mains—Factory-Installed Main Circuit Breaker— QOM2 Main Frame Size—Convertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)—Copper Bus j 22 kA 20 30 10 QO12030M150C 562.00 PK18GTA 12.50 4–250 9 150 A 22 kA 30 30 0 QO130M150C 580.00 PK18GTA 12.50 4–250 9 22 kA 20 40 20 QO12040M200C 562.00 PK23GTA 14.20 4–250 9 22 kA 30 30 0 QO130M200C 597.00 PK18GTA 12.50 4–250 9 200 A 22 kA 30 40 10 QO13040M200C 649.00 PK23GTA 14.20 4–250 9 22 kA 40 40 0 QO140M200C 758.00 PK23GTA 14.20 4–250 10 Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b Order F for flush device or S for surface device. c Mains rating 25 A when Al wire is used. d Will not accept Qwik-Gard® QO-GFI circuit breaker. e Use 10 AWG maximum size wire for GFI circuit breakers. f Main circuit breaker is a field-installed standard QO single pole circuit breaker. Order separately from page 1-2. g 70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker. h UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. i UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. j 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22,000 A available fault current. k One main circuit breaker is included with panel. NEMA 1 indoor device requires cover ordered separately. Alternate source main circuit breaker (QO 125 A max) ordered separately. Automatic Transfer switch and Generator for secondary power source are ordered through a Kohler authorized dealer or contractor. l Device is rated NEMA 3R and can be used for indoor or outdoor applications. m Universal mains—no factory installed main circuit breaker or main lugs. QOM2 frame size—field install 22 k AIR main circuit breaker or main lugs (see page 1-5 or 1-6). Table 1.26: Auxiliary Gutter UL Listed for use with standard 1Ø and 3Ø load centers for riser applicationsn. For auxiliary gutter-load center compatibility, see Catalog 1100CT0501 n o Table 1.27: Cat. No. $ Price Cover SDAG26 225.00 Flush One tap kit required for each riser wire. When used with B300 bolt-on hubs. Conduit Riser Size 1-3/4, 2, 2-1/2 or o3 Width 13.50 Height 26.12 Depth 3.75 Tap Kits 120/240 Vac—UL Listed For Use With Auxiliary Gutters SDAG26 Cat. N0. $ Price Use With Auxiliary Gutter Cat. No. SDGT30020 SDGT300300 54.00 80.00 SDAG26 SDAG26 SDGT300C10C 33.10 SDAG26 SDGT300C300C 46.90 SDAG26 QOGL20 Grounding Terminals 27.10 SDAG26 © 2007 Schneider Electric All Rights Reserved Riser Wire Lug Type Mechanical (Included) Mechanical (Included) Anderson VCEL030516H1 (Not included) Anderson VCEL030516H1 (Not included) Mechanical (Included) DE3A Discount Schedule Tap Off Wire Al/Cu Wire Size (2) 6 AWG–300 kcmil (2) 6 AWG–300 kcmil (2) 4 AWG–300 kcmil (2) 4 AWG–300 kcmil (2) 6–2/0 AWG Lug Type Mechanical (Included) Mechanical (Included) Anderson VCEL02114S1 (Not Included) Anderson VCEL030516H1 (Not included) — Al/Cu Wire Size (1) 6–2/0 AWG (1) 6 AWG–300 kcmil (1) 8–1/0 AWG (1) 4 AWG–300 kcmil — 1-9 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com QO® and Homeline® Load Centers Load Center Value Pack Class 1130, 1170 / Refer to Catalog 1100CT0501 www.us.schneider-electric.com FOR CURRENT INFORMATION 1 Load Center Value Pack LOAD CENTERS Mains Rating 1Ø3W—120/240 Vac—UL Listed—Convertible Mains—Factory-installed Main Circuit Breaker Complete Load Center (Box, Interior and Cover) and Selected Branch Circuit Breakers Spaces Table 1.28: Max. 1P Circuitsa Max. Tandem Circuit Breakers Equipment Ground Bar Kit (Order Separately) Load Center Box, Interior, Cover and Branch Circuit Breakers Cat. No. Included Load Center/Circuit Breakers $ Price QO—Copper Bus—Order extra QO, QOT, QO-EPD, QO-GFI, QO-AFI branch circuit breakers from pages 1-2 and 1-3. Main Circuit Breaker 100 A 32 32 0 QOVP2 (1) QO132M100C, (5) QO120 200 A 30 40 10 QOVP1 (1) QO13040M200C, (5) QO120 200 A 30 40 10 QOVP10 (1) QO13040M200C, (10) QO120 Homeline—Order extra HOM, HOMT, HOM-GFI, HOM-AFI branch circuit breakers from page 1-13. Main Lugs 125 A 12 24 12 HOMVPL2 (1) HOM1224L125TC, (5) HOM120 200 A 30 40 10 HOMVPL1 (1) HOM3040L200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 Main Circuit Breaker 100 A 20 20 0 HOMVP4 (1) HOM20M100C, (5) HOM115 100 A 20 20 0 HOMVP5 (1) HOM20M100C, (5) HOM120 150 A 30 30 0 HOMVP12 (1) HOM30M150C, (5) HOM120, (1) HOM230 200 A 20 40 20 HOMVP16 (1) HOM2040M200TC, (5) HOM120, (1) HOM230 200 A 30 40 10 HOMVP1 (1) HOM3040M200TC, (5) HOM120, (1) HOM230 200 A 30 40 10 HOMVP2 (1) HOM3040M200TC, (5) HOM115, (1) HOM230 200 A 30 40 10 HOMVP9 (1) HOM3040M200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 200 A 30 40 10 HOMVP14 (1) HOM3040M200TC, (12) HOM120, (1) HOM230, (1) HOM250 200 A 40 40 0 HOMVP15 (1) HOM40M200C, (10) HOM120 I N D O O R R A I N P R O O F Cat. No. 559.00 735.00 885.00 PK18GTA PK23GTA PK23GTA 235.00 641.00 Included Included 352.00 352.00 655.00 643.00 722.00 722.00 885.00 885.00 897.00 PK15GTA PK15GTA PK23GTA Included Included Included Included Included PK23GTA 835.00 PK23GTA Main Box No. Wire Size See AWG/kcmil Pages Al/Cu 1-16, 1-17 $ Price 12.50 14.20 14.20 4–2/0 4–250 4–250 8 9 9 6–2/0 4–250 6 10 11.40 11.40 14.20 — — — — — 14.20 4–2/0 4–2/0 4–250 4–250 4–250 4–250 4–250 4–250 4–250 8 8 10 9 10 10 10 10 12 14.20 4–250 6R — — Homeline—Order extra HOM, HOMT, HOM-GFI, HOM-AFI branch circuit breakers from page 1-13. Main Circuit Breaker 200 A 20 40 20 HOMVPRB1 (1) HOM2040M200RB, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. Riser Panels Table 1.29: 1Ø3W 120/240 Vac—Offset Interior Wide Gutter—30 A Maximum Branch Circuit Breaker on left side of interior bc New! Mains Rating Spaces Max. Single Pole Circuitsd Max. Tandem Circuit Breakers Load Center Box and Interior Cat. No. Load Center Cover $ Price Cat. No. $ Price Equipment Ground Bar Kit (Order Separately) Cat. No. Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Current Rating QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5) when used with QOC cover below—Copper Bus 125 A 12 24 12 QO11224L125WG 225.00 QOC20UFWG 35.00 PK15GTA 125 A 20 30 10 QO12030L125WG 310.00 QOC20UFWG 35.00 PK15GTA I N Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Current Rating D O QOM2 Main Frame Size–Convertible to Main Circuit Breaker (See page 1-5) when used with QOC cover below–Copper Bus O 200 A 30 40 10 QO13040L200WG 467.00 QOC30UFWG 68.00 PK23GTA R Convertible Mains—Factory-installed Main Circuit Breaker—22 kA Short Circuit Current Rating QOM2 Main Frame Size–Convertible to Main Lugs (See page 1-6)—Copper Bus QO124M200WG125 200 A 24 24 0 455.00 QOC30UFWG 68.00 PK23GTA e Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. b UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. c UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. d Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. e Comes with 125 A main circuit breaker factory installed. Main Wire Size AWG/kcmil $ Price Al Cu Box No. See Page 1-16 11.40 11.40 6–2/0 6–2/0 14 14 14.20 4–250 23 14.20 4–250 23 Panelboard-style Covers for Riser Panels Mono-Flat® Front available for riser panels as an alternative to standard load center cover listed above. Provides a low-profile, aesthetically pleasing solution for high-traffic areas in upscale multi-family applications. Deadfront included. Lock kit not provided. Cannot be used when panel has been converted to main breaker panel. f f 1-10 Mains Rating of Load Center Cat. No. 125 A NQC20FWG 200 A NQC30FWG Order catalog number PK4FL for field installable lock kit. $ Price 78.00 120.00 DE3A Discount Schedule © 2007 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Load Center Accessories QO Load Center Accessories www.us.schneider-electric.com Class 1130 / Refer to Catalog 1100CT0501 FOR CURRENT INFORMATION QO Load Center Accessories Cat. No. $ Price Schedule PK2MB 4.80 DE3A PK3MB PK5RK 9.80 9.80 DE3A DE3A PK4MB2LA 9.80 DE3A PK4MB2HA 9.80 DE3A QO2DTI 16.60 DE2E QO2DTIM 42.00 DE2E PK4DTIM4LA 68.00 DE3A PK4DTIM4HA 68.00 DE3A PK4DTIM4LAL 68.00 DE3A QOCRBGK1 70.00 DE3A QOCGK2 70.00 DE3A QORBGK2 70.00 DE3A QO1SE SDSA1175 SDSA3650 QO2175SB HOM2175SB 2.40 61.00 165.00 106.00 106.00 DE3A DE1B DE1B DE1B DE1B QOSAMK 7.60 DE3A LSDL .36 DE5 PSDS .50 DE5 LOAD CENTERS Description Secures circuit breaker to interior when used as a back-fed main. For QO612L100F/S, RB, QO612L100DF/S, QO816L100F/S, RB, QO816L100DF/S and QO148L125GF/S, GRB load centers Secures 3P circuit breaker without accessories to left side of interior when used as a back-fed main. For 3Ø load centers Secures circuit breaker to interior when used as a back-fed main for 2P QO 150–200 A circuit breakers. Retaining Kit Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main. For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that only one circuit breaker can be “ON’’ at a time QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual power supply applications. Can be used with (2) 2P or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers. Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for Manual Transfer Equipment Kit back-up power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back-up power supply applications. For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. Secures two 2P circuit breakers to left side of interior when used as back-fed mains, a QO2DTI Kit included for back-up power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. For use on “G” and “S” Series NEMA 1 and “G”, “S1” and “S2” Series NEMA 3R load centers. Interlocks a New! QOM1 2P main circuit breaker of a load center (100–125 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. Generator Circuit Breaker For use on “G” and “S” Series NEMA 1 and “G” and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main Interlock Kit circuit breaker of a load center (150–225 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. Cover Sealing Strap: Provides means of sealing trim mounting screws on QO load center covers For use on 1Ø3W, 150 Vac maximum For use on 3Ø4W, 650 Vac maximum Surge Arresters: QO Surgebreaker CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum. Homeline Surgebreaker CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum. Miscellaneous Surge Arrester UL Listed for mounting SDSA1175 surge arrester into ground bar mounting holes on 1Ø convertible main circuit breaker Mounting Kit: load centers Replacement Cover 1 through 42 numbered universal replacement directory label for load center covers Directory Label: Circuit Identification Circuit identification stickers for use on cover directory labels to identify branch circuits Stickers: 1 Table 1.30: PK2MB QOSAMK QO2DTI 6 OFF 1 ON ON 4 3 2 ON OFF 5 ON OFF OFF PK3MB QO2DTI Installed QOCGK2 Installed PK4DTIM4HA © 2007 Schneider Electric All Rights Reserved DE1B DE2E DE3A DE5 Discount Schedule 1-11 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com QO® and Homeline® Accessories and Voltage testers Load Center Accessories Class 1130, 6610 / Refer to Catalog 1100CT0501 www.us.schneider-electric.com FOR CURRENT INFORMATION 1 Table 1.31: QO Load Center Accessories LOAD CENTERS Description Cat. No. Fills opening in covers if twistout is removed in error QOFP Fills main circuit breaker opening in convertible load center covers100–125 A QOM1FP Filler Plates Fills main circuit breaker opening in convertible load center covers150–225 A QOM2FP Fills main circuit breaker opening in 3Ø load center covers (S01 and S02 Series) KFP Fills main circuit breaker opening in “Q” style 3Ø load center covers (S03 Series) Q2FP Use with convertible mains, 1Ø and 3Ø 100–225 A, and fixed mains, 3Ø 125–225 A indoor load centers PK6FLa Lock Kits Use with 300 and 400 ampere indoor load centers PK4FL Field-installed for 12– 2 Al or 14–4 Cu AWG wire LK70AN Field-installed for 6–2/0 Al/Cu AWG wire LK100AN Neutral / Ground Lugs Field-installed for 14–2/0 Al/Cu AWG wire LK125AN Field-installed for 2–3/0 Al/Cu AWG wire LK150AN Field-installed for 4 AWG to 300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO or HOM load center LK225AN Standard PK15GTA with a 1–4/0 Al/Cu Lug PK15GTAL Standard PK18GTA with a 1–4/0 Al/Cu Lug PK18GTAL Ground Bar Kits Standard PK23GTA with a 1–4/0 Al/Cu Lug PK23GTAL Insulator Kit for PK7GTA through PK27GTA PKGTAB For padlocking main circuit breakers in convertible load centers OFF..........50–125 A, QOM1 Frame Size QOM1PA Handle Padlock Attachment: For padlocking main circuit breakers in convertible load centers OFF..........100–225 A, QOM2 Frame Size QOM2PA a QO612L100DF/S, QO816L100DF/S, QO612L100DFCU/SCU, QO816L100DFCU/SCU and QO403L60NF/S DO NOT have provisions for field-installed lock. $ Price Schedule 2.40 DE3A 13.50 DE3A 13.50 DE3A 13.50 DE3A 13.50 DE3A 62.00 DE3A 60.00 PE1A 6.70 DE3A 7.20 DE3A 14.70 DE3A 21.60 DE3A 22.10 DE3A 23.30 DE3A 25.20 DE3A 27.10 DE3A 29.20 DE3A 7.30 DE2E 7.30 DE2E QOFP PKGTAB PK4FL PK6FL Table 1.32: Homeline Load Center Accessories Description Handle Padlock Attachment: 50–125 A 100–225 A For padlocking main circuit breakers in convertible load center, “OFF” Fills opening in covers if twistout is removed in error Filler Plates Field-installed for 14–2 AWG Al or 14–4 AWG Cu wire Field-installed for 6–2/0 AWG Al/Cu wire Field-installed for 14–2/0 AWG Al/Cu wire Field-installed for 4 AWG–300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO or HOM load center Secures circuit breaker to interior when used as a back-fed main. For HOM612L100F/S, RB and HOM48L125GC, GRB load centers. Secures ONE circuit breaker right side of interior when used as a back-fed main. For 100–125 A convertible main load centers, Series S01 and S02 Secures ONE circuit breaker right side of interior when used as a back-fed main. For 150–225 A convertible main load centers, Series S01 and S02 Secures circuit breaker to interior when used as a back-fed main. For 2P 150–200 A circuit breakers Neutral Lugs Retaining Kit Miscellaneous New! Generator Circuit Breaker Interlock Kit 100–125 A 150–225 A Fills main circuit breaker opening in convertible load centers Cat. No. QOM1PA QOM2PA HOMFP QOM1FP QOM2FP LK70AN LK100AN LK125AN LK225AN $ Price Schedule 7.30 DE2E 7.30 DE2E 2.10 DE3C 13.50 DE3A 13.50 DE3A 6.70 DE3B 7.20 DE3B 14.70 DE3B 22.10 DE3A HOM1RK 4.30 DE3C HOM4RK2LA 9.80 DE3C HOM4RK2HA 9.80 DE3C HOM5RK 9.80 DE3C DE3A Lock Kit Use with convertible indoor load center covers (Series S-1) PK6FL 62.00 Replacement Cover Directory Label 1 through 42 numbered universal replacement directory label for load center covers LSDL .36 DE5 PSDS .50 DE5 Circuit Identification Circuit identification stickers for use on cover directory labels to identify branch circuits Stickers: For use on “S” Series NEMA 1 and “S1” and “S2” Series NEMA 3R load centers. Interlocks a QOM1 2P main circuit breaker of a load center (100–125 A) with a Homeline 2P (15–125 A) branch circuit breaker. For use on “S” Series NEMA 1 and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker. For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker. HOMCRBGK1 70.00 DE3D HOMCGK2 70.00 DE3D HOMRBGK2 70.00 DE3D Table 1.33: Voltage Testers Solenoid Type with polarity indication and slotted receptacles for holding prods. UL and CSA Listed. Description The Type Voltage Tester 120-240-480-600 Vac 50/60 Hz; 120-240-600 Vdc Same as VT-1 except with fused leads Deluxe Simulated Leather Carrying Case Replacement Polarity Indication Cap b Replacement Leads b Fused Replacement Leads b b Wiggy® Voltage Tester 1-12 $ Price Schedule 6610VT1 67.00 DE3B 6610VT1S 74.00 DE3B 6610L2 39.30 DE3B 6610PC1 8.00 DE3B 6610P1 25.70 DE3B 6610P1S 35.50 DE3B IMPORTANT: Will fit only Class 6610 Series A testers and Catalog Number 5008, Series B testers. Will not fit 5008 Pre-Series B testers. Leads must be replaced as a unit. Replacement of individual lead components must not be attempted. DE2E DE3A DE3B DE3C DE3D DE3E DE5 PE1A Discount Schedule © 2007 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com www.us.schneider-electric.com Homeline® Circuit Breakers Plug-On Circuit Breakers Class 1170 / Refer to Catalog 1100CT0501 FOR CURRENT INFORMATION Table 1.34: HOM 2P 2 Spaces Required HOM2200BB Branch Circuit Breaker 4 Spaces Required HOM Ampere Rating AIR 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 110 A 125 A 150 A 175 A 200 A 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 1P—120/240 Vac Cat. No. HOM115 ab HOM120 ab HOM125 b HOM130 b — HOM140 b — HOM150 b — — — — — — — — — — New! HOM 1P AFI (Arc Fault Circuit Interrupter) 1 Space Required 1P—120/240 Vac Amperes Cat. No. HOM115HMb HOM120HMb Circuit Breaker Type Arc-fault Circuit Interrupter Combination Arc-fault Circuit interrupter — — — Poles 120 Cat. No. Vac 1 HOM115AFIb 1 HOM120AFIb 1 HOM115CAFIb 1 HOM120CAFIb 150.00 150.00 150.00 150.00 AIR 10 kA 10 kA 10 kA 10 kA 10 kA Table 1.38: 1 Space Required Cat. No. HOM115GFI HOM120GFI — — — 2 Spaces Required $ Price 141.00 141.00 — — — Cat. No. HOM215GFI HOM220GFI HOM230GFI HOM240GFI HOM250GFI $ Price 275.00 275.00 275.00 275.00 275.00 HOM-EPD—10 k AIR Homeline Equipment Protection Device—Circuit Breakers with 30 mA Equipment Ground Fault Protection (UL Listed) 15 A 20 A 25 A 30 A 40 A 50 A 2P—120/240 Vac Common Trip 1P—120 Vac Cat. No. HOM115EPD HOM120EPD — — — — $ Price 249.00 249.00 — — — — DE3D Cat. No. HOM215EPD HOM220EPD HOM225EPD HOM230EPD HOM240EPD HOM250EPD DE3C DE2E $ Price 440.00 440.00 440.00 440.00 440.00 440.00 Discount Schedule AIR 1P Tandem—120/240 Vac (One Space Required) Cat. No. $ Price 15 and 15 A 10 kA HOMT1515 b 34.90 15 and 20 A 10 kA HOMT1520 b 34.90 20 and 20 A 10 kA HOMT2020 b 34.90 30 and 15 A 10 kA HOMT3015 b 34.90 30 and 20 A 10 kA HOMT3020 b 34.90 a UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. b UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. Table 1.40: HOMT Quad Tandem Circuit Breakers Ampere Ratingd AIR 2P Tandem—120/240 Vac (Two Spaces Required) 1P 2P Cat. No. $ Price (2) 15 A 15 A 10 kA HOMT1515215 b 80.00 (2) 15 A 20 A 10 kA HOMT1515220 b 80.00 (2) 15 A 25 A 10 kA HOMT1515225 b 80.00 (2) 15 A 30 A 10 kA HOMT1515230 b 80.00 (2) 15 A 40 A 10 kA HOMT1515240 b 80.00 (2) 15 A 50 A 10 kA HOMT1515250 b 80.00 (2) 20 A 20 A 10 kA HOMT2020220 b 80.00 (2) 20 A 25 A 10 kA HOMT2020225 b 80.00 (2) 20 A 30 A 10 kA HOMT2020230 b 80.00 (2) 20 A 40 A 10 kA HOMT2020240 b 80.00 (2) 20 A 50 A 10 kA HOMT2020250 b 80.00 Note: Typical catalog number (e.g. HOMT 1515230) represents two 1P, outer poles (two 15 A 1P CBs) and one 2P inner circuit breaker with common trip (one 30 A 2P CB). Circuit Breaker Wire Sizese Wire Size (AWG/kcmil) Breaker Type Ampere Rating Aluminum HOM 1P 15–30 A 14–8 AWG HOM 2P $ Price 2P—120/240 Vac Common Trip 1P—120 Vac Amperes © 2007 Schneider Electric All Rights Reserved Ampere Rating 15 A 20 A 15 A 20 A Ampere Rating d Table 1.41: 2Ps $ Price 18.40 18.40 HOM-GFI circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 milliamperes or more. Table 1.37: HOM-GFI 15 A 20 A 30 A 40 A 50 A HOM 2P GFI (With Ground Fault Circuit Interrupter) 2 Spaces Required $ Price 40.30 40.30 40.30 40.30 40.30 40.30 40.30 40.30 40.30 82.00 112.00 112.00 112.00 246.00 246.00 285.00 285.00 285.00 Homeline Arc Fault Circuit Interrupters—Provide overload and short circuit protection, plus arc fault protection in accordance with UL 1699. Table 1.36: HOM-AFI Ampere Rating HOM 1P GFI (With Ground Fault Circuit Interrupter) 1 Space Required Cat. No. HOM215b HOM220b HOM225b HOM230b HOM235b HOM240b HOM245b HOM250b HOM260b HOM270b HOM280b HOM290b HOM2100 b HOM2110 b HOM2125 b HOM2150BB bc HOM2175BB bc HOM2200BB bc High magnetic trip circuit breakers are recommended for applications where high initial inrush current may occur. Table 1.35: HOM-HM 15 A 20 A HOMT Quad Circuit Breaker 2 Space Required 2P—120/240 Vac Common Trip $ Price 17.50 17.50 17.50 17.50 — 17.50 — 17.50 — — — — — — — — — — HOMT Tandem Circuit Breakers HOMT and Quad Quad Only HOM-GFI - 1P HOM-GFI - 2P Table 1.42: LOAD CENTERS HOM 1P 1 Space Required Table 1.39: 1 The Square D Homeline circuit breakers are in a 1 in. wide format for 1-pole circuit breakers. They are designed to plug into Homeline load centers that are available from 4 to 42 circuits. The Square D exclusive Qwik-Open® mechanism, with a trip reaction within 1/60th of a second, is standard on all 15 A and 20 A circuit breakers. 40–50 A 8–2 AWG 15–30 A 14–8 AWG 35–70 A 80–125 A 150–200 A 15–30 A 40–50 A 15–20 A 15–50 A 8–2 AWG 4–2/0 AWG 4 AWG–300 kcmil 14–8 AWG 6–12 AWG 14–10 AWG 12–4 AWG Copper 14–8 AWG or (2) 14–10 AWG 8–2 AWG 14–8 AWG or (2) 14–10 AWG 8–2 AWG 4–2/0 AWG 4 AWG–300 kcmil 14–8 AWG 6–14 AWG 14–10 AWG 14–6 AWG Accessories Description Cat. No. $ Price Handle Attachments Handle Tie: Converts any two adjacent 120/240 Vac HOM1HTg 2.30 single HOM circuit breakers to independent trip 2P Handle Tie: Converts any two adjacent 120/240 Vac 1P side-by-side HOMT circuit breakers to independent HOMTHTg 2.50 trip 2P Handle Clamp: Clamp for holding HOM 1P handle in QO1LOh 2.50 the ON or OFF position Handle Blocking Device: Attaches to standard HOM 2P circuit breakers for holding the handle in the OFF HOM2HBDg 7.10 position Handle Padlock Attachment: For padlocking 1P HOM1PAg 2.60 Standard HOM breakers in the ON or OFF position. 15–70 A HOM2PALAg 6.60 Handle Padlock Attachment: For padlocking 2P Standard HOM circuit 80–125 A HOM2PAHAg 6.60 breakers in ON or OFF position 150–200 A HOM2PAVHAg 33.60 Handle Padlock Attachment: For padlocking center HOMQPA 6.60 poles of Homeline Quad breakers in the OFF position. Handle Padlock Attachment: For 50–125 A QOM1PAfh 7.20 padlocking main circuit breakers in convertible load center 100–225 A QOM2PAfh 7.20 in OFF position Sub-Feed Lugs 125 A 2P plug-on—2 spaces required HOML2125 31.70 225 A 2P plug-on—4 spaces required HOML2225c 197.00 c Requires four spaces (1 AWG–300 kcmil Al/Cu). Use only in 1Ø panel rated 150 A or greater. d 15–20 A tandem or quad tandem circuit breakers are suitable for use with 60oC or 75oC conductors. 25–50 A tandem or quad tandem circuit breakers are suitable for use with 75oC conductors only. e 15–30 A circuit breakers are suitable for use with 60oC or 75oC conductors. 40–125 A circuit breakers are suitable for use with 75oC conductors. f 50–125 A QOM1 frame size; 100–225 A QOM2 frame size. g DE3C Discount Schedule h DE2E Discount Schedule 1-13 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com Homeline® Load Centers Indoor, 1Ø, Main Lug, Main Circuit Breaker Class 1170 / Refer to Catalog 1100CT0501 www.us.schneider-electric.com FOR CURRENT INFORMATION 1 Table 1.43: Mains Rating 1Ø3W—120/240 Vac—UL Listed—10 kA Short Circuit Current Rating Spaces Max. Single Pole Circuits a Max. Tandem Circuit Breakers Load Center Box, Interior and Cover b Main Wire Size AWG/kcmil $ Price (DE3C) Cat. No. Al Cu Equipment Ground Bar Kit (Order Separately) Cat. No. $ Price (DE3A) Box No. See Page 1-16 LOAD CENTERS Main Lugs—Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from page 1-13 Factory-installed Fixed Main Lugs 70 A 2 4 2 HOM24L70F/Sdc 100 A 6 12 6 HOM612L100F/Sce 125 A 4 8 4 HOM48L125GC Convertible Mains—Factory-installed Main Lugs QOM1 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See page 1-15) 8 16 8 HOM816L125C 8 16 8 HOM816L125TC 12 12 0 HOM12L125C 12 24 12 HOM1224L125TC 125 A 16 24 8 HOM1624L125C 20 20 0 HOM20L125C 20 24 4 HOM2024L125TC 24 24 0 HOM24L125TC Convertible Mains—Factory-installed Main Lugs QOM2 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See page 1-15) 30 30 0 HOM30L150C 150 A 30 30 0 HOM30L150TC 16 32 16 HOM1632L200TC 200 A 16 32 16 HOM1632L200TCFTf 20 40 20 HOM2040L200TC 30 30 0 HOM30L200C 30 30 0 HOM30L200TC 200 A 30 40 10 HOM3040L200TC 40 40 0 HOM40L200C 40 40 0 HOM40L200TC 225 A 42 42 0 HOM42L225C I N D O O R 39.20 52.00 57.00 12–3 14–4 8–1 12–2/0 88.00 100.00 116.00 136.00 173.00 158.00 192.00 229.00 250.00 264.00 238.00 383.00 278.00 280.00 309.00 319.00 412.00 447.00 488.00 14–2/0 6–2/0 PK3GTA1 7.60 PK7GTA 7.80 PK7GTA Factory-included PK15GTA Factory-installed PK15GTA Factory-installed PK15GTA PK15GTA Factory-installed Factory-installed 11.40 — 11.40 — 11.40 11.40 — — 6–250 6–250 PK23GTA Factory-installed — 6–250 Factory-installed — 6–250 6–250 PK23GTA Factory-installed Factory-installed PK23GTA Factory-installed PK23GTA 14.20 14.20 — — 14.20 — 14.20 2 4 21 6 6 6 6 8 8 8 8 10 10 9 10 9 10 10 10 12 12 12 Main Circuit Breaker—22 kA Short Circuit Current Rating Convertible Mains—Factory-installed Main Circuit Breaker QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 1-15) 8 16 8 HOM816M100C 210.00 8 16 8 HOM816M100TC 222.00 12 12 0 HOM12M100C 196.00 100 A 12 24 12 HOM1224M100TC 256.00 20 20 0 HOM20M100C 264.00 24 24 0 HOM24M100C 342.00 30 30 0 HOM30M100C 448.00 12 24 12 HOM1224M125C 404.00 12 24 12 HOM1224M125TC 413.00 125 A 24 24 0 HOM24M125C 473.00 30 30 0 HOM30M125C 541.00 Convertible Mains—Factory-installed Main Circuit Breaker QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 1-15) 16 32 16 HOM1632M150TC 424.00 20 30 10 HOM2030M150TC 500.00 150 A 30 30 0 HOM30M150C 517.00 12 24 12 HOM1224M200TC 381.00 16 32 16 HOM1632M200TC 450.00 20 40 20 HOM2040M200C 474.00 20 40 20 HOM2040M200TC 509.00 200 A 30 30 0 HOM30M200C 532.00 30 40 10 HOM3040M200TC 594.00 40 40 0 HOM40M200C 679.00 42 42 0 HOM42M200C 729.00 225 A 42 42 0 HOM42M225C 744.00 6–1 6–1 4–2/0 4–2/0 4–2/0 4–2/0 4–2/0 4–2/0 4–250 4–250 4–250 PK15GTA Factory-installed PK15GTA Factory-installed PK15GTA PK15GTA PK23GTA PK15GTA Factory-installed PK15GTA PK23GTA Factory-installed Factory-installed PK23GTA Factory-installed Factory-installed PK23GTA Factory-installed PK23GTA Factory-installed PK23GTA PK23GTA PK23GTA 11.40 — 11.40 — 11.40 11.40 14.20 11.40 — 11.40 14.20 — — 14.20 — — 14.20 — 14.20 — 14.20 14.20 14.20 5 5 6 6 8 8 10 6 6 8 10 9 9 10 9 9 9 9 10 10 12 12 12 Universal Mains—No Factory-installed Main Circuit Breaker or Main Lugs QOM2 Main Frame Size—Field-install 22 k AIR Main Circuit Breaker or Main Lugs (See page 1-15) 16 32 16 HOM1632U200TC 195.00 200 A 20 40 20 HOM2040U200TC 238.00 4–250 30 40 10 HOM3040U200TC 353.00 Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers. b C at end of catalog number indicates combination flush/surface cover included with device. c F/S at end of catalog number indicates to order F for flush device or S for surface device. The cover does not have a door. d HOM-GFI branch circuit breaker is limited to number 10 maximum wire. e 70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker. f Supplied with feed-thru lugs. 1-14 DE3A DE3C Discount Schedule Factory-installed Factory-installed Factory-installed — — — 9 9 10 © 2007 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com www.us.schneider-electric.com Homeline® Load Centers Rainproof, 1Ø, Main Lug, Main Circuit Breakers Class 1170 / Refer to Catalog 1100CT0501 FOR CURRENT INFORMATION Table 1.44: 1Ø3W 120/240 Vac UL Listed Load Centers Mains Rating Spaces Max. Single Pole Circuits a Max. Tandem Circuit Breakers Load Center Box, Interior and Cover Cat. No. (DE3C) Main Wire Size AWG/kcmil $ Price Al Cu Equipment Ground Bar Kit (Order Separately) Cat. No. (DE3A) $ Price Box No. See Page 1-17 Main Circuit Breaker (Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from Page 1-13), 22 kA Short Circuit Current Rating Convertible Mains with Factory-Installed Main Circuit Breaker, QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) d 16 8 HOM816M100RB 286.00 PK15GTA 11.40 8 12 12 0 HOM12M100RB 277.00 PK15GTA 11.40 100 A 4–2/0 20 20 0 HOM20M100RB 354.00 PK15GTA 11.40 24 24 0 HOM24M100RB 404.00 PK15GTA 11.40 125 A 24 24 0 HOM24M125RB 572.00 4–2/0 PK15GTA 11.40 1R 2R 15R 3R 3R 3R 4R 5R 6R 7R 14R 1 R A I N P R O O F Factory-installed Fixed Main Lugs, 10 kA Short Circuit Current Rating 70 A 2 4 2 HOM24L70RBb 74.00 12–3 14–4 PK4GTA 7.20 100 A 6 12 6 HOM612L100RBf 86.00 8–1 PK7GTA 7.80 125 A 4 8 4 HOM48L125GRB 91.00 12–2/0 14–2/0 PK7GTA Factory-included Convertible Mains with Factory-installed Main Lugs c, QOM1 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See Below) 8 16 8 HOM816L125RB 165.00 PK15GTA 11.40 12 12 0 HOM12L125RB 156.00 PK15GTA 11.40 125 A 6–2/0 12 24 12 HOM1224L125RB 185.00 PK15GTA 11.40 20 20 0 HOM20L125RB 255.00 PK15GTA 11.40 Convertible Mains with Factory-installed Main Lugs c, QOM2 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See Below) 12 12 0 HOM12L200RB 282.00 PK23GTA 14.20 20 40 20 HOM2040L200RB 373.00 PK23GTA 14.20 200 A 6–250 30 30 0 HOM30L200RB 391.00 PK23GTA 14.20 40 40 0 HOM40L200RB 607.00 PK23GTA 14.20 LOAD CENTERS Main Lugs (Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from Page 1-13), 10 kA Short Circuit Current Rating 3R 3R 4R 6R 6R Convertible Mains with Factory-installed Main Circuit Breaker, QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) 150 A 30 30 0 HOM30M150RB 685.00 4–250 PK23GTA 14.20 7R 20 40 20 HOM2040M200RB 581.00 PK23GTA 14.20 6R 30 30 0 HOM30M200RB 669.00 PK23GTA 14.20 7R 200 A 4–250 30 40 10 HOM3040M200RB 768.00 PK23GTA 14.20 7R 40 40 0 HOM40M200RB 851.00 PK23GTA 14.20 14R 16 24 8 HOM1624M225RB 788.00 PK15GTA 11.40 7R 225 A 4–250 42 42 0 HOM42M225RB 882.00 PK23GTA 14.20 14R Convertible Mains with Factory-installed Main Circuit Breaker with Feed-thru Lugs c 150 A 8 16 8 HOM816M150FTRB 523.00 4–250 PK15GTAL 23.30 6R 200 A e 8 16 8 HOM816M200FTRB 523.00 4–250 PK15GTAL 23.30 6R Universal Main with Feed-thru Lugs—No Factory-installed Main Circuit Breaker or Main Lugs c QOM2 Main Frame Size—Field-install 22 k AIR Main Circuit Breaker or Main Lugs (See Kits Below) 200 A 8 16 8 HOM816U200FTRB 297.00 4–250 PK15GTAL 23.30 6R Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers. b HOM-GFI branch circuit breaker is limited to number 10 maximum wire. c Side hinge door device allow 1-1/4 in. on left side for door to open. d 22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. e Rated 200 A when using copper wire. Reference NEC® Table 310.15(B)(6) when using Al wire. f 70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker. R A I N P R O O F Field-installable Kits Table 1.45: Main Lug Kit QOL125 QOL225 © 2007 Schneider Electric All Rights Reserved Field-installable Mains, Convertible Load Centers Only Main g Use On Convertible Load $ Price Lug Wire Size j Cat. No. Ampere Rating Center With Mains Rating (DE3A) AWG/kcmil 125 A 100–125 A QOL125 29.40 6–2/0 Al or Cu Main Lug h — 225 A 150–225 A QOL225 69.00 6–300 Al or Cu 50 A 100–125 A QOM50VH 93.00 60 A 100–125 A QOM60VH 93.00 70 A 100–125 A QOM70VH 93.00 80 A 100–125 A QOM80VH 134.00 QOM1 12–2/0 Al or Cu 90 A 100–125 A QOM90VH 134.00 100 A 100–125 A QOM100VH 134.00 110 A 125 A QOM110VH 312.00 Main Circuit Breaker i 125 A 125 A QOM125VH 312.00 100 A 150–225 A QOM2100VH 312.00 125 A 150–225 A QOM2125VH 312.00 150 A 150–225 A QOM2150VH 312.00 QOM2k 4–300 Al or Cu 175 A 200–225 A QOM2175VH 312.00 200 A 200–225 A QOM2200VH 312.00 225 A 225 A QOM2225VH 312.00 g Do not exceed the load center mains rating. h If main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from page 1-12. i 22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. j Wire range listed for main device kits is the wire range of that device. To find out maximum wire size permitted in a particular load center per UL, see pages 1-5 through 1-10 under Main Wire Size. k Add suffix 1021 for 120, 208, 240 Vac shunt trip. Add $126.00. Field-installable Main Type Frame Size DE3A DE3C Discount Schedule 1-15 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com QO® and Homeline® Load Centers Indoor Load Centers–Dimensions, Knockouts Class 1130, 1170 / Refer to Catalog 1100CT0501 www.us.schneider-electric.com FOR CURRENT INFORMATION 1 A Indoor Knockout Information and Enclosure Dimensions A,B,C,D A,B,C A,B,C A A,B,C A Table 1.46: Enclosure Dimensions A,B,C Dimensions A LOAD CENTERS A A,B A B,C,D,E B,C,D,E C,D,E,F,G A A,B B,C,D,E C,D,E,F B,C,D,E A,B A A B,C,D,E B,C,D,E A,B,C,D B,C,D,E Table 1.47: C,D,E,F,G C,D,E,F,G mm 171 236 236 319 379 455 531 661 758 858 965 1000 in. 3.00 3.19 3.19 3.80 3.75 3.75 3.75 3.75 3.75 3.75 3.75 3.75 W Box No. mm 76 81 81 97 95 95 95 95 95 95 95 95 in. 5.88 14.25 20.00 20.00 20.00 5.88 7.56 9.62 8.88 8.55 14.25 13 14 15 16 17 18 19 20 21 22 23 H mm 149 362 508 508 508 149 192 244 226 217 362 in. 13.12 20.92 50.00 68.00 53.00 16.12 23.12 26.12 14.80 23.92 29.86 D mm 333 531 1270 1727 1346 409 587 663 376 608 758 in. 3.38 3.75 5.75 5.75 5.75 3.38 4.25 4.75 3.80 3.95 3.75 mm 86 95 146 146 146 86 108 121 97 100 95 Knockout Information Knockouts A A,B A B C Conduit Size 1/2 3/4 1 C,D,E,F,G D E 1-1/4 1-1/2 F G H I 2 2-1/2 3 3-1/2 C,D,E,F,G B,C,D,E C,D,E,F A A,B D,E,F,G C,D,E,F B,C,D,E C,D,E,F A A,B D in. 6.72 9.30 9.30 12.57 14.92 17.92 20.92 26.04 29.86 33.78 37.98 39.37 Symbol B,C,D,E B,C,D,E B,C,D,E mm 97 122 122 226 362 362 362 362 362 362 362 362 Box 5 Box 4 Dimensions H in. 3.81 4.81 4.81 8.88 14.25 14.25 14.25 14.25 14.25 14.25 14.25 14.25 1 2 3 4 5 6 7 8 9 10 11 12 Box 3 Box 2 Box 1 B,C,D,E A A,B W Box No. B,C,D,E C,D,E,F A A,B B,C,D,E D,E,F,G B,C C,D,E,F,G D,E,F,G A A,B B,C,D,E D,E,F,G B,C A,B B,C,D,E C,D,E,F A,B A,B A A,B A A A A,B,C,D A,B,C,D Box 6 B,C,D,E C,D,E,F C,D,E,F,G D,E,F,G B,C,D,E Box 7 C,D,E,F,G D,E,F,G Box 10 A A,B C,D,E,F D,E,F,G A,B B,C B,C A,B,C,D C,D,E,F D,E,F,G Box 9 Box 8 B,C,D,E B,C,D,E A A,B B,C,D,E D,E,F,G A,B,C,D C,D,E,F D,E,F,G A,B,C,D D,E,F,G,H D,E,F,G,H,I C,D,E,F A,B,C A A,B D,E,F,G A,B B,C,D,E A,B C,D,E,F C,D,E,F A,B,C,D A A,B A A A,B,C,D C,D,E,F D,E,F,G A,B,C,D B,C,D,E A,B,C,D B,C,D,E C,D,E,F Box 14 Box 13 Box 12 Box 11 Box 15, 16, 17 A,B,C A C,D,E,F D,E,F,G B,C C,D,E,F E,F,G,H C,D,E,F A,B,C,D D,E,F,G A,B D,E,F,G D,E,F,G A,B B,C,D,E D,E,F,G A B,C,D,E A,B B,C,D,E B,C,D,E A A A,B B,C,D,E B,C,D,E C,D,E,F Box 18 1-16 Box 19 Box 20 Box 21 A,B,C,D C,D,E,F D,E,F,G B,C,D,E Box 22 Box 23 © 2007 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com QO® and Homeline® Load Centers www.us.schneider-electric.com Rainproof—Dimensions, Knockouts, Bolt-on Hubs Class 1130, 1170 / Refer to Catalog 1100CT0501 FOR CURRENT INFORMATION 2 1 2" Hub Maximum 2 1 2" Hub Maximum Table 1.48: Enclosure Dimensions Dimensions W A A,B A,B,C,D Box Box 1NM 1NM B,C,D,E A B,C,D,E Box 1R B,C,D,E A,B Box 2R 2 1 2" Hub Maximum 2 1 2" Hub Maximum C,D,E,F,G C,D,E,F,G C,D,E,F A,B,C A A,B C,D,E,F,G C,D,E,F Box 3R, 4R C,D,E,F 2 1 2" Hub Maximum A,B,C A A,B C,D,E,F,G C,D,E,F a Table 1.49: Box 5R mm 99 102 108 115 115 115 115 115 115 99 105 121 140 105 115 108 106 LOAD CENTERS B,C B,C A,B A,B D in. 3.90 4.00 4.27 4.52 4.52 4.52 4.52 4.52 4.52 3.88 4.12 4.75 5.50 4.12 4.52 4.27 4.16 1 H in. mm in. mm 1NM 6.52 166 8.79 223 1Ra 4.88 124 9.38 238 2R 8.88 226 12.65 321 3R 14.75 375 18.92 481 4R 14.75 375 22.06 560 5R 14.75 375 26.04 661 6R 14.75 375 29.86 758 7R 14.75 375 33.78 858 8R 14.75 375 37.98 965 9R 4.56 116 6.50 165 10R 6.92 176 13.18 335 11R 7.56 192 23.24 590 12R 9.62 244 26.24 666 13R 6.92 176 16.18 411 14R 14.75 375 39.37 1000 15R 8.88 226 14.80 376 16R 8.55 217 24.75 629 HOME250SPA and QO260NATR top endwall has no hub opening. Box No. Knockout Information Knockouts C,D,E,F,G Symbol A B C Conduit Size 1/2 in. 3/4 in. 1 in. D E 1-1/4 in. 1-1/2 in. F G H 2 in. 2-1/2 in. 3 in. 2 1 2" Hub Maximum 2 1 2" Hub Maximum 2 1 2" Hub Maximum A,B,C C,D,E,F A,B,C A A,B C,D,E,F,G C,D,E,F Box 9R Box 6R, 7R, 8R 2 1 2" Hub Maximum 2 1 2" Hub Maximum B,C,D,E D,E,F,G B,C,D,E A,B Box 15R Box 12R 2 1 2" Hub Maximum C,D,E,F,G C,D,E,F B,C,D,E A E,F E,F,G,H B,C,D,E A,B,C,D B,C,D,E Box 10R, 13R D,E,F,G Box 11R A,B C,D,E,F A,B,C A A,B C,D,E,F,G C,D,E,F C,D,E,F Box 16R Box 14R Bolt-On Hubs Square D equipment with “R’’ or “RB’’ suffix, designated NEMA 3R rainproof construction, utilizes bolt-on hubs listed below. “RB’’ devices will accept 3⁄ 4" through 2-1⁄ 2" bolt-on hubs without the use of reducers. Off-center conduit thread openings and elongated mounting holes provide quick and easy adjustment to eliminate costly conduit offsets and bends. Catalog suffix “R’’ devices require 3" through 4" field cut opening. Hubs are suitable for use with conduit having ANSI standard taper pipe thread. Table 1.50: 3/4 in. 1 in. 1-1/4 in. 1-1/2 in. 2 in. 2-1/2 in. Hub Cat. No. B075 B100 B125 B150 B200 B250 b $ Price 22.20 22.20 22.20 22.20 40.90 68.00 Closing cap (Cat. No. BCAP) is provided factory-installed on each device having “RB’’ suffix. Price if ordered separately; $2.50 Table 1.51: “RB’’ Hub Bolt-On Hubs UL Listed for Mounting in Field-Cut Opening Conduit Size 3 in. 3-1/2 in. 4 in. Hub Cat. No. B300 B350 B400 $ Price © 2007 Schneider Electric All Rights Reserved Bolt-On Hubs UL Listed for “RB” Devicesb Conduit Size DE1A 124.00 Discount Schedule 200.00 Designed for mounting in field cut opening. Includes gasket and four mounting bolts and nuts. 245.00 1-17 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com