Models: 650/1000KRP Dual Voltage Electrical Power Panel Industrial Trailer-Mounted Generator Sets Fuel Tank D Kohlerr Rental provides one-source responsibility for the power generating system and accessories. D Generator set features: d Premium sound-attenuated ISO container with dBA rating of <70 dBA @ 7 m (23 ft.) d Adjustable trip circuit breaker d Easy-to-use Kohler Power Systems-designed Decision-Makert 3+ controller d Emergency stop switch mounted at the floor inside of the engine room door d Internal fuel tank with fill/spill feature and secondary fluid containment basin sized at 115% of total volume d Field-configurable fuel transfer system with connections, controller, and transfer pump d Control panel and circuit breaker in one convenient location d Hospital-grade silencer and rain cap with non-bypass turbocharger exhaust system meeting U.S. Forestry spark arrestor requirements d AC input connection (shore power) box for block heater and battery charger d Easy access curb-side cable and load lug hatch d Manufactured by Kohlerr Power Systems Load Lug Access Generator Set 650KRP 150.00 [3810.0] Electrical Power Panel 22.00 [558.8] 143.76 [3651.6] GENSET MOUNTED NOTE 2 CONTROL PANEL Fuel TankINTAKE AIR FLOW D NOTE 4 NOTE 1 CABLE ACCESS AREAS SHORE POWER AND LOAD CABLE ACCESS DOOR D 30.00 [762.0] 49.00 [1244.6] 371.50 [9436.1] Load Lug 100.00 [2540.0] Access Engine features: d Closed crankcase ventilation system d Electronic isochronous governor providing precise frequency regulation d Engine block heater d Engine oil makeup system d Fuel/water separator with bypass valve d Heavy-duty air cleaner with air restriction indicator O 15AMMETER 510 DC 10 15 20 05DC 25 VOLTS Generator Set Trailer features: d Fire extinguisher d Interior work lights with timer d Two access doors with stowable stairs and safety railing d Running lights with standard DOT 7-way receptacle INTAKE AIR FLOW NOTE 6 FLOW Diesel 48.00 [1219.2] 38.00 [965.2] 1000KRP D Remote monitoring (GPS) features: d Issues alerts for low oil pressure, low fuel level, and common faults d Issues alerts for unauthorized movement of equipment d Monitors and issues reports for service intervals d Tracks low battery conditions G32-14 6/07 Trailer-Mounted Generator Set Specifications Kohler Rental Model Trailer[ Length mm (in.) 650KRP 9144 (360) 1000KRP 12192 (480) Trailer[ Width mm (in.) Trailer[ Height mm (in.) 2438 (96) 4115 (162) Gross Weight* kg (lb.) Ambient Temperature, _C (_F) Sound Level dBA with No Load at 7 m (23 ft.) 18785 (41415) 45 (113) 69.1 23587 (52000) 45 (113) 67.9 * Gross weight includes trailer, generator set, and fuel tank without fuel. [ Trailer dimensions include the enclosure, chassis, and axle/wheels. Generator Set Ratings 130_C Rise Standby Rating 105_C Rise Prime Rating Kohler Rental Model Generator Set Model Alternator Model 208 Volt, 3 Phase 480 Volt, 3 Phase 208 Volt, 3 Phase 480 Volt, 3 Phase Amps kW/kVA Amps kW/kVA Amps kW/kVA Amps kW/kVA 650KRP 650REOZDB 5M4032 2290 660/825 992 660/825 2082 600/750 902 600/750 1000KRP 1000REOZDB 7M4045 3470 1000/1250 1504 1000/1250 3161 910/1138 1368 910/1138 GENERAL GUIDELINES FOR DERATION: Altitude: Derate 1.0% per 100 m (328 ft.) elevation above 400 m (1312 ft.). Temperature: Derate 3.0% per 5.0_C (9_F) temperature above 40_C (104_F). See the respective spec sheets for specifications not shown. See the Additional Literature table for generator set and controller spec sheet part numbers. Fuel Consumption at Standby Rating, Lph (gph) Fuel Consumption at Prime Rating, Lph (gph) Generator Set Model Engine 650REOZDB DDC Series 2000 90.2 (23.8) 132.1 (34.9) 173.5 (45.8) 86.7 (22.9) 127.2 (33.6) 165.6 (43.8) 2829 (750) 1000REOZDB DDC Series 2000 138.2 (36.5) 202.4 (53.3) 267.2 (70.6) 128.6 (33.9) 189.3 (50.0) 247.6 (65.4) 3785 (1000) 50% Load 75% Load 100% Load 50% Load 75% Load 100% Load Fuel Tank L (gal.) Electrical Power Panel Specifications Kohler Rental Model Load Lug Connections Circuit Breaker Trip Setting, Amps 208-- 240 Volt 480 Volt 650KRP (6) 1/0--750 kcmil 2000 900 1000KRP (6) 1/0--750 kcmil 3520 1600 Available Selector Switch Voltages Voltages, 3 Phase, 60 Hz 120/208 277/480 G32-14 6/07 Shore Power Connection for Battery Charger and Block Heater 15 amp/120 p volt, NEMA L5-15P for battery y charger h and d 50 amp/240 /240 volt, lt H Hubbell bb ll CS8275 twistlock for block heater Remote Start Capability Y Yes Electrical Power Panel with Main Circuit Breaker (650KRP model shown) View from Engine Room into Control Room View from Control Room, Access Door Open 1 Exterior Load Connection Box 3 2 11 1 7 8 9 2 3 4 5 10 12 15 6 14 13 6 E8-15871 13 1. 2. 3. 4. 5. Battery charger Control panel GFCI relay box with indicator light Panelboard Timer, 0--60 min. 6. 7. 8. 9. 10. Main circuit breaker Voltage adjust switch (raise/lower) Prime power switch (650KRP model only) Control room status lights Power connection, block heater 11. 12. 13. 14. 15. Exterior load box status lights Power connection, battery charger Neutral bus Remote start connections Ground bus Voltage Selector Switch, 650/1000KRP Voltage Adjust (Raise/Lower) (1000KRP model only) Voltage Selector Switch Prime Power Switch (Battery Supply Disconnect) (1000KRP model only) G32-14 6/07 KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-459-1634; Fax 920-459-1846 For the nearest sales and service outlet in the US and Canada, phone 1-888-769-3794 or KohlerRental.com Generator Set Decision-Makert 3+ Controller Other Equipment - Chillers and accessories - Heating/cooling units - Luxury restrooms Additional Literature Generator Set Model Gen. Set Spec Sheet 650REOZDB G5-244 1000REOZDB G5-247 Power Accessories - Automatic transfer switches - Cable and cable ramps - Disconnects - Distribution boxes - I-line panels - Light towers - Transformers - _______________________________________________ - _______________________________________________ - _______________________________________________ - _______________________________________________ DISTRIBUTED BY: Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohlerr Rental regional office for availability. © 2007 by Kohler Co. All rights reserved. G32-14 6/07 Generator Set Controller Controller Spec Sheet D i i M k t 3+ Decision-Makert 3 G6 30 G6-30