Railway applications • Relays • Time relays • Monitoring relays • Sockets Devices for superior requirements Reliable and Safe Solutions for Railway and Transportation Applications Solutions for the transport market need to guarantee safety, security and comfort. The applications are expected to last a long time under challenging conditions. Be it for high-speed trains, metros, subways or other rail vehicles – in tunnels, on bridges, in train stations, airports, on the open track, or in harbor facilities, the Comat Releco Group has the right solution for different kind of applications. We offer a wide range of relays, control and monitoring devices that are developed in compliance with the European Railway Standard EN 50155 (including also EN 61373, EN 45545 and NF F 16-101/102). The EN 50155 standard applies for all electronic devices such as command, control, protection units, as well as power supplies, which are used in the transportation market. It applies either to the accumulator battery side or also the low-voltage power supply part of the vehicle. Regarding fire protection, the products offered in this brochure are manufactured in accordance with standard NF F 16-101/102. A table a the last page of this brochure shows the overview of the products and the standards they comply with. Individual declarations of conformity are available on demand. Please do not hesitate to contact us for any further questions or comments. Comat AG Bernstrasse 4 3076 Worb Switzerland www.comat.ch info@comat.ch Railway applications C31D/R4 Long life series with twin contacts C32D/R5 Standard relay R3-N3x 6 Standard relay R4-A4x 7 Miniature relay R7-A2x8 Miniature relay R7-T2x9 Interface relay CINT-2110 Interface relay CINT-2211 Interface relay CINT-2512 Interface relay CINT-6113 Interface relay CINT-6214 Interface relay CINT-6315 Signal relay C203.06R16 Power relay RIC20-x17 Power relay RIC25-x18 2. Time Relays Time functions Page 19 20 Multifunction Timer, relay change-over CIM1R21 Multifunction Timer, solid-state AC CIM12R 22 23 Multifunction Timer, solid-state DC CIM13R Multifunction Timer, relay change-over CIM2R24 Multifunction Timer, solid-state AC CIM22R25 Multifunction Timer, solid-state DC CIM23R26 Multifunction Timer, relay change-over CIM3R27 Multifunction Timer, semi-conductor AC CIM32R28 Multifunction Timer, semi-conductor DC CIM33R29 CT-System: Plug-in time modules CT32R, CT33R, CT36R30 CT32…R, CT33…R, CT36…R31 Plug-in time relays 3. Monitoring Relays 34 3-phase monitoring MRU32R 35 1-phase monitoring MRI11R36 3-phase monitoring MRI32R37 1-phase monitoring MRM11R 38 3-phase monitoring MRM32R 39 CT-System: Plug-in current monitoring modules CT512R, CT515R, CT516R 40 Plug-in current monitoring set CT512…R, CT515…R, CT516…R 42 Plug-in DC voltage monitoring module CT524R41 Plug-in DC voltage monitoring set CT524…R42 Insulation monitoring 4. ESU-D2R43 Sockets 2 Page 33 MRU11R 1-phase monitoring 1 Time Relays Long life series with single contacts Page 3 Monitoring Relays Relays 3 Sockets 1. Relays Index Page 45 Socket for 11 pin relays and plug-in modules C11A (for relays: C31D/R, C32D/R, R3-N3) 46 Socket for 11 pin relays and plug-in modules C12B0 (for relays: C31D/R, C32D/R, R3-N3) 47 Socket for 14 pin relays CS-144 (for relays: R4-A4x) 48 Socket for miniature relays CS-118 (for relays: R7-x) 49 4 Notes 2 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Relays 1 1.Relays ApplicationTypes Output contacts Design 11 pin plug-in, long life relay C31D/R 10 A, 250V AC-1 11 pin plug-in, long life relay C32D/R 6 A, 250V AC-1 11 pin plug-in, standard relay R3-N3… 6 A, 250V AC-1 14 pin plug-in, standard relay R4-A4… 8 pin plug-in, miniature standard relay R7-A2… 10 A, 250V AC-1 8 pin plug-in, miniature standard relay R7-T2… 6A, 250V AC-1 Interface relay CINT-21 6A, 250V AC-1 Interface relay CINT-22 6A, 250V AC-1 Interface relay CINT-25 2A, 250V AC-1 Interface relay CINT-61 10A, 250V AC-1 Interface relay CINT-62 8A, 250V AC-1 Interface relay CINT-63 8A, 250V AC-1 Interface relay C203.06 Power relay RIC20-… Power relay RIC25-… 10 A, 250V AC-1 2x 2A, 125V AC-1 ; This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. ; ; 20 A, 230V AC-1 ; 25 A, 230V AC-1 Railway/01a.12 | 3 Long life series with single contacts C31D/R 11 pin plug-in relay, 3-pole, change-over contacts, according to IEC 60067 Type: C31D/R …V Long Life Relays for Railway application, 3 change-over contacts Types with LED status indicator Types with free wheeling diode Manual actuator and mech. status indicator 10 A / 250 V AC-1 10 A / 30 V DC-1 50 mA / 10 V Contacts Type single contact micro disconnection MaterialAgCuNi Rated current 10 A Inrush current max. (20 ms) 40 A Switching voltage AC-1 max. 250 V AC load max. 2500 VA AC-1 DC load max. see Fig. 2 Coils (Values are valid at 20 °C) Operating voltage range Nominal power DC Coil Table Connection diagram 0.7 … 1.25 U N 1.2 W VN DC 24 36 72 110 8 9 5 7 4 3 2 32 34 22 24 12 14 A1 (+) 31 21 11 A2 11 6 1 10 Fig. 1 AC voltage endurance Ω 340 780 3200 9700 mA 70 46 23 11 107 AC-1 Cycles Maximum contact load Recommended minimum contact load 106 Types with LED indicator take additional 5 … 10 mA @ < 80 V Insulation Pulse (1.2 / 50 us / Dielectric strength (V rms, 1 minute) Contact / coil – / 2.5 kV Contact / contact – / 2.5 kV Contact open – / 1.5 kV -40 … +70 °C / -40 … +85 °C 12 ms 20 ms 3.5 ms ≥ 108 operations ≤ 360 operations / h IP 40 80 g 2 3 4 5 6 7 Switching current [ A ] 8 9 10 DC-1 L/R 40 ms 4 3 2 1 0.5 0.3 0.2 0 50 100 150 200 250 Voltage [ V ] C31D/R DC…V "…" Enter the voltage for full type designation Dimensions [mm] 31 51 34 32 11 A1 A2 C11A, C12B0 35 Accessories Socket: 1 10 8 6 0.1 Standard types DC: 24, 36, 72, 110 V 0 Fig. 2 DC load limit curve Current [A] General Specifications Ambient temperature operation / storage Pick-up time typ. Release time typ. Bounce time NO contact typ. Mechanical life Operating frequency at nominal load Ingress protection rating Weight 105 10 11 1 2 9 3 8 4 24 7 6 5 21 14 12 22 35 Technical approvals, conformities See table on page 53. 4 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Long life series with twin contacts C32D/R Relays 11 pin plug-in relay, 3-pole, change-over twin contacts, according to IEC 60067 Type: C32D/R …V Long Life Relays for Railway application, 3 change-over twin contacts Types with LED status indicator Types with free wheeling diode Manual actuator and mech. status indicator 1 6 A / 250 V AC-1 6 A / 30 V DC-1 10 mA / 5 V Contacts Type twin contact micro disconnection MaterialAgCuNi Rated current 6A Inrush current max. (20 ms) 15 A Switching voltage AC-1 max. 250 V AC load max. 1500 VA AC-1 DC load max. see Fig. 2 Coils (Values are valid at 20 °C) Operating voltage range Nominal power DC Coil Table Connection diagram 0.7 … 1.25 U N 1.2 W VN DC 24 36 110 Ω 340 780 9700 mA 70 46 11 31 21 11 A2 11 6 1 10 107 Insulation Pulse (1.2 / 50 us / Dielectric strength (V rms, 1 minute) Contact / coil – / 2.5 kV Contact / contact – / 2.5 kV Contact open – / 1.5 kV AC-1 106 0 1 2 3 4 Switching current [A] 5 6 Fig. 2 DC load limit curve 10 8 6 4 3 Current [A] -40 … +70 °C / -40 … +85 °C 12 ms 20 ms 3.5 ms ≥ 108 operations ≤ 360 operations / h IP 40 80 g DC-1 L/R 40 ms 2 1 0.5 0.3 0.2 Standard types DC: 24, 36, 110 V 2 A1 (+) Fig. 1 AC voltage endurance Types with LED indicator take additional 5 … 10 mA @ < 80 V General Specifications Ambient temperature operation / storage Pick-up time typ. Release time typ. Bounce time NO contact typ. Mechanical life Operating frequency at nominal load Ingress protection rating Weight 8 9 5 7 4 3 32 34 22 24 12 14 Cycles Maximum contact load Recommended minimum contact load C32D/R DC…V 0.1 0 50 100 150 Voltage [V] 200 250 "…" Enter the voltage for full type designation Accessories Socket: Dimensions [mm] C11A, C12B0 31 35 51 32 11 A1 A2 34 10 11 1 2 9 3 8 4 24 7 6 5 21 14 12 22 35 Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01a.12 | 5 Standard Relays R3-N3… 11-pin plug-in relay, 3-pole, change-over contacts, according to IEC 60067 Type: R3-Nxx/…V Relays for Railway application, 3 change-over contacts Maximum contact load Recommended minimum contact load 6 A / 250 V AC-1, 6 A / 30 V DC-1 10 mA / 10 V Code 4 5 mA / 5 V Code 8 Contacts Material Optional Optional Rated current Inrush current max. (20 ms) Switching voltage AC-1 max. AC load max. DC load max. AgNi + 0.2µ Au AgNi + 10µ Au 6A 15 A 250 V see Fig. 1 see Fig. 2 Coil (Values are valid at 20 °C) Coil resistance Operating voltage range Nominal power Coil Table Connection diagram 4 3 5 7 8 12 14 22 24 32 34 11 21 31 A2 1 6 11 10 see table; tolerance ± 10 % 0.7 … 1.25 U N 1.1 W V DC Ω mA 24 48 72 110 525 2133 4844 12900 46 22 15 9 Insulation Pulse (1.2 / 50 us / Dielectric strength (V rms, 1 minute) Contact / coil 4 kV / 2.5 kV Contact / contact 4 kV / 2.5 kV Contact open 1.5 kV / 1 kV Standard types DC: 24, 48, 72, 110 V Free wheeling diode LED LED + free wheeling diode R3-N34/DC…V R3-N34D/DC…V R3-N34X/DC…V R3-N34DX/DC…V R3-N38/DC…V R3-N38D/DC…V R3-N38X/DC…V R3-N38DX/DC…V* 106 Accessories Socket: Optional accessories (blanking plug): C11A, C12B0 SO-NP, SO-OP 0 1 2 3 4 Switching current [ A] 6 5 6 DC-1 L/R 40 ms 4 3 2 1 0.5 0.3 0.2 0.1 "..." Enter the voltage for full type designation AC-1 cos phi 0.4 Fig. 2 DC load limit curve Current [A] - 25 (no ice) … +70 ºC / -40 … +80 °C 18 ms / ≤ 3 ms 35 ms / ≤ 1 ms > 10 millions IP 40 95 g 2 A1 (+) 107 105 Specifications Ambient temperature operation / storage Pick-up time / bounce time Release time / bounce time (D version) Mechanical life Ingress protection rating Weight 9 Fig. 1 AC voltage endurance Cycles Code 4 Code 8 0 50 100 150 Voltage [ V ] 200 250 Dimensions [mm] 1 11 A1 9 58.5 8 4 3 35 2 10 A2 7 6 5 35 Technical approvals, conformities See table on page 53. 6 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Standard Relays R4-A4… Relays 14-pin plug-in relay, 4-pole, change-over contacts Type: R4-A4xx/…V Relays for Railway application, 4 change-over contacts Maximum contact load Recommended minimum contact load 6 A / 250 V AC-1, 0.5 A / 110 V DC-1 6 A / 30 V DC-1, 0.2 A / 220 V DC-1 10 mA / 10 V Code 4 5 mA / 5 V Code 8 Contacts Material Optional Optional Rated current Inrush current max. (20 ms) Switching voltage AC-1 max. AC load max. DC load max. AgNi + 0,2 µ Au AgNi + 10 µ Au 6A 18 A 250 V see Fig.1 see Fig. 2 Code 4 Code 8 Coil (Values are valid at 20 °C) Coil resistance Operating voltage range Nominal power 1 Connection diagram 1 2 4 5 7 8 10 11 13 12 14 22 24 32 34 42 44 A1 (+) see table; tolerance ± 10 % 0.7 … 1.25 U N 1.4 W 11 21 31 41 A2 3 6 9 12 14 Fig. 1 AC voltage endurance V DC Ω mA 24 36 48 72 110 426 881 1500 3456 8231 56 41 32 21 13 107 Cycles Coil Table Insulation Pulse (1.2 / 50 us / Dielectric strength (V rms, 1 minute) Contact / coil 4 kV / 2.5 kV Contact / contact 4 kV / 2.5 kV Contact open 1.5 kV / 1 kV -25 (no ice) … +55 °C / -40 … +80 °C 15 ms / ≤ 2 ms 20 ms / ≤ 2 ms > 20 millions IP40 90 g Standard types DC: 24, 36, 48, 72, 110 V LED Free wheeling diode Polarity and free wheeling diode R4-A44/DC…V R4-A44X/DC…V R4-A44DX/DC…V R4-A44FX/DC…V 106 105 R4-A48/DC…V R4-A48X/DC…V R4-A48DX/DC…V R4-A48FX/DC…V 0 1 2 3 4 Switching current [ A] 5 6 Fig. 2 DC load limit curve 6 DC-1 L/R 40 ms 4 3 2 Current [A] Specifications Ambient temperature operation / storage Pick-up time / bounce time Release time / bounce time Mechanical life Ingress protection rating Weight AC-1 cos phi 0.4 1 0.5 0.3 0.2 0.1 0 50 100 150 Voltage [ V ] 200 250 "..." Enter the voltage for full type designation Dimensions [mm] CS-144 SO-NP, SO-OP 35 1 52.5 Accessories Socket: Optional accessories (blanking plug): 4 2 5 7 10 11 8 6 9 3 12 13 14 35 3 Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01a.12 | 7 Miniature relays R7-A2… 8-pin plug-in miniature relay, 2-pole, change-over contacts Type: R7-A2x/…V Relays for Railway application, sensitive, 2 change-over contacts Maximum contact load: Recommended minimum contact load 10 A / 250 V AC-1, 10 A / 30 V DC-1 10 mA / 10 V Code 4 5 mA / 5 V Code 8 Contacts Material Optional Optional Rated current Inrush current max. (20 ms) Switching voltage AC-1 max. AC load max. DC load max. AgNi + 0.2µ Au AgNi + 10µ Au 10 A 30 A 250 V see Fig. 1 see Fig. 2 Coil Table Ω ± 10% 535 2004 4750 11337 mA 45 24 15 10 Insulation Pulse (1.2 / 50 us / Dielectric strength (V rms, 1 minute) Contact / coil 4 kV / 2.5 kV Contact / contact 4 kV / 2.5 kV Contact open 1.5 kV / 1 kV Standard types DC: 24, 48, 72, 110 V LED: Free wheeling diode: LED + free wheeling diode: R7-A24/DC…V R7-A24X/DC…V R7-A24D/DC…V R7-A24DX/DC…V 11 21 A2 5 6 8 0 1 2 3 4 5 6 7 Switching current [ A] 8 9 10 Fig. 2 DC load limit curve 10 8 6 4 3 DC-1 L/R 40 ms 2 1 0.5 0.3 0.2 0 50 100 150 Voltage [ V ] 200 250 Dimensions [mm] 37.5 CS-118 AC-1 cos phi 0.4 106 0.1 "..." Enter the voltage for full type designation Accessories Socket: R7-A28/DC…V R7-A28X/DC…V R7-A28D/DC…V R7-A28DX/DC…V 7 A1(+) 107 Current [A] -25 (no ice) … +70 ºC / -40 … +80 °C > 20 millions 10 ms 15 ms IP40 35 g 4 Fig. 1 AC voltage endurance 105 Specifications Ambient temperature operation / storage Number of mechanical operations Pick-up time typ. Release time typ. Ingress protection rating Weight 2 22 24 see table; tolerance ±10 % 0.7 … 1.25 U N 1.1 W V DC 24 48 72 110 3 1 12 14 28 Coil (Values are valid at 20 °C) Coil resistance Operating voltage range Nominal power Connection diagram Cycles Code 4 Code 8 1 2 3 4 5 7 A 6 8 B 21 4.75 Technical approvals, conformities See table on page 53. 8 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Miniature relays R7-T2… Relays 8-pin plug-in miniature relay, 2-pole, change-over twin contacts Type: R7-T2x/…V Relays for Railway application, 2 change-over twin contacts Maximum contact load Recommended minimum contact load 6 A / 250 V AC-1, 6 A / 30 V DC-1 5 mA / 5 V Code 1 1 mA / 5 V Code 2 Contacts Material Standard Optional Rated current Inrush current max. (20 ms) Switching voltage AC-1 max. AC load max. DC load max. AgNi + 0.2µ Au AgNi + 10µ Au 6A 15 A 250 V see Fig. 1 see Fig. 2 Connection diagram 1 3 12 Coil Table see table; tolerance ± 10 % 0.7 … 1.25 U N 1.1 W V DC 24 48 72 110 Ω ± 10% 535 2004 4750 11337 mA 45 24 15 10 Insulation Pulse (1.2 / 50 us / Dielectric strength (V rms, 1 minute) Contact / coil 4 kV / 2.5 kV Contact / contact 4 kV / 2.5 kV Contact open 1.5 kV / 1 kV Standard types DC: 24, 48, 72, 110 V LED: Free wheeling diode: LED + free wheeling diode: R7-T21/DC…V R7-T21X/DC…V R7-T21D/DC…V R7-T21DX/DC…V R7-T22/DC…V R7-T22X/DC…V R7-T22D/DC…V R7-T22DX/DC…V CS-118 21 A2 5 6 8 AC-1 0 1 2 3 4 Switching current [ A] 6 5 6 DC-1 L/R 40 ms 4 3 2 1 0.5 0.3 0.2 0 50 100 150 Voltage [ V ] 200 250 Dimensions [mm] 37.5 Accessories Socket: 11 106 0.1 "..." Enter the voltage for full type designation 7 A1(+) Fig. 2 DC load limit curve Current [A] -25 (no ice) … +70 ºC / -40 … +80 °C > 20 millions 10 ms 15 ms IP40 35 g 4 24 107 105 Specifications Ambient temperature operation / storage Number of mechanical operations Pick-up time typ. Release time typ. Ingress protection rating Weight 2 22 Fig. 1 AC voltage endurance Cycles Coil (Values are valid at 20 °C) Coil resistance Operating voltage range Nominal power 14 28 Code 1 Code 2 1 1 2 3 4 5 7 A 6 8 B 21 4.75 Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01a.12 | 9 Interface relays 6.2 mm CINT-21 Interface module with mechanical change-over output contact, DIN rail mounting Types: CINT-21/…V Standard interface module, 1 change-over contact Cage clamp terminal Control voltage UC 24 V, 50/60 Hz Green LED for status indication Max. contact load 6 A / 250 V AC-1 Contact Data Type micro disconnection MaterialAgSnO2 Rated current 6A Inrush current max. (5 ms) 30 A Switching voltage AC-1 max. 250 V AC load max. 1500 VA DC load max. see Fig. 2 Recommended min. contact load 10 mA / 12 V Connection diagram RELAY A1 Control input Vn = Operating voltage range Typical input current Nominal power consumption UC 24 V 16.3 … 30 V 11 mA 260 mW Fig. 1 AC voltage endurance 107 Cycles -40 … + 70 °C / -40 … + 85 °C 5 ms 10 ms ≥ 107 / ≥ 105 operations stranded wire 0.5 … 1.5 mm2 IP 20 any Polyamid 105 104 0 1 2 3 4 6 Fig. 2 DC load limit curve 6 5 CINT-21/UC24V CINT-BR20 (2 x 10 pin) CINT-BEZ/64 (64 pieces) CINT-R1/DC24V 5 Switching current [A] DC-1 2 Current [A] Accessories Plug-in bridges: Label plate: Replacement relay for CINT-21: AC-1 106 Standard types UC 24 (AC/DC): 11 12 SOCKET Insulation Pulse (1.2 / 50 us / Dielectric strength (V rms, 1 minute) Contact / coil 6 kV / 4 kV Contact open 1.5 kV / 1 kV General Specifications Ambient temperature operation / storage Typical response time @ Vn Typical release time @ Vn Service life mech. / elec. Cond. cross section cage clamp terminal Ingress protection rating Mounting position Housing material 14 A2 1 0.5 0.3 0.2 0.1 0 50 100 150 Voltage [ V ] 200 250 Dimensions [mm] Connector bridge CINT-BR20 12 11 49,2 14 44,3 TS35 93,5 Label included CINT-BR8 A1 A2 6,2 3,4 73 Technical approvals, conformities See table on page 53. 10 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Interface relays 6.2 mm CINT-22 Relays Interface module with mechanical change-over output contact, DIN rail mounting Types: CINT-22/UC24V Standard interface module, 1 change-over contact Cage clamp terminal Control voltage UC 24 V, 50/60 Hz Green LED for status indication Max. contact load 6 A / 250 V AC-1 Contact Data Type Material Rated current Inrush current max. (20 ms) Switching voltage AC-1 max. AC load max. DC load max. Recommended min. contact load micro disconnection Ag Ni +5μ Au 6A 10 A 250 V 1500 VA see Fig. 2 1 mA / 1 V Control input Vn = Operating voltage range Typical input current Nominal power consumption UC 24 V 16.8 … 30 V 11 mA 260 mW 1 Connection diagram RELAY A1 Fig. 1 AC voltage endurance 107 106 105 104 1 2 3 4 6 5 CINT-22/UC24 V CINT-BR20 (2 x 10 pin) CINT-BEZ/64 (64 pieces) CINT-R2/DC24V 5 6 Fig. 2 DC load limit curve DC-1 2 Current [A] Accessories Plug-in bridges: Label plate: Replacement relay for CINT-22: 0 Switching current [A] Standard types UC 24 (AC/DC): AC-1 Cycles -40 … +70 °C / -40 … +85 °C 5 ms 10 ms ≥ 107 / ≥ 105 operations stranded wire 0.5 … 1.5 mm2 IP 20 any Polyamid 11 12 SOCKET Insulation Pulse (1.2 / 50 us / Dielectric strength (V rms, 1 minute) Contact / coil 6 kV / 4 kV Contact open 1.5 kV / 1 kV General Specifications Ambient temperature operation / storage Typical response time @ Vn Typical release time @ Vn Service life mech. / elec. Cond. cross section cage clamp terminal Ingress protection rating Mounting position Housing material 14 A2 1 0.5 0.3 0.2 0.1 0 50 100 150 Voltage [ V ] 200 250 Dimensions [mm] Connector bridge CINT-BR20 12 11 49,2 14 44,3 TS35 93,5 Label included CINT-BR8 A1 A2 6,2 3,4 73 Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01a.12 | 11 Interface relays 6.2 mm CINT-25 Interface module with solide state DC output, DIN rail mounting Types: CINT-25/UC24V Standard interface module, Solide state DC Cage clamp terminal Control voltage UC 24 V, 50/60 Hz Green LED for status indication Max. contact load 2 A / 24 V DC-1 Contact Data Type Material Rated current Inrush current max. (10 ms) Switching voltage DC-1 max. DC load max. Recommended min. contact load micro disconnection Solide state 2A 20 A 30 V 48 W 1 mA, 6 V Control input Vn = Operating voltage range Typical input current Nominal power consumption UC 24 V 16.8 … 30 V 11 mA 260 mW Connection diagram RELAY (+) A1 14 A2 11 12 SOCKET Insulation Pulse (1.2 / 50 us / Dielectric strength (V rms, 1 minute) Input / output – / 2.5 kV General Specifications Ambient temperature operation / storage Typical response time @ Vn Typical release time @ Vn Cond. cross section cage clamp terminal Ingress protection rating Mounting position Housing material -40 … + 55 °C / - 40 … + 85 °C 1 ms 1 ms stranded wire 0.5 … 1.5 mm2 IP 20 any Polyamid Standard types UC 24 (AC/DC): Accessories Plug-in bridges: Label plate: Replacement relay for CINT-25: CINT-25/UC24V CINT-BR20 (2 x 10 pin) CINT-BEZ/64 (64 pieces) CINT-R5/DC24V Dimensions [mm] Connector bridge CINT-BR20 12 11 49,2 14 44,3 TS35 93,5 Label included CINT-BR8 A1 A2 6,2 3,4 73 Technical approvals, conformities See table on page 53. 12 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Interface relays 14 mm CINT-61 Relays Interface module with mechanical change-over output contact, DIN rail mounting Types: CINT-61/UC24V Standard interface module, 1 change-over contact Cage clamp terminal Control voltage UC 24 V, 50/60 Hz Green LED for status indication Contact Data Type micro disconnection MaterialAgSnO2 Rated current 10 A / (16 A*) Inrush current max. (5 ms) 80 A Switching voltage AC-1 max. 250 V AC load max. 4000 VA DC load max. see Fig. 2 Recommended min. contact load 10 mA, 24 V * For currents > 10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12) Control input Vn = Operating voltage range Typical input current Nominal power consumption UC 24 V 16.8 … 30 V 20 mA 480 mW Insulation Pulse (1.2 / 50 us / Dielectric strength (V rms, 1 minute) Contact / coil 6 kV / 4 kV Contact open 1.5 kV / 1 kV General Specifications Ambient temperature operation / storage Typical response time @ Vn Typical release time @ Vn Service life mech. / elec. Cond. cross section cage clamp terminal Ingress protection rating Mounting position Housing material 1 10 A / 250 V AC-1 -40 … + 70 °C / -40 … + 85 °C 5 ms 10 ms ≥ 107 / ≥ 105 operations stranded wire 0.5 … 1.5 mm2 IP 20 any Polyamid Connection diagram RELAY A1 Fig. 1 AC voltage endurance 107 CINT-BR8/5 (5 pieces x 8 pin) CINT5-BEZ/18 (18 pieces) CINT-R21/DC24V AC-1 106 105 104 0 2 4 6 8 10 12 Switching current [A] 14 16 Fig. 2 DC load limit curve 10 16 10 DC-1 5 Current [A] Accessories Plug-in bridges: Label plate: Replacement relay for CINT-61: CINT-61/UC24 V 22 21 24 SOCKET Standard types UC 24 (AC/DC): 12 11 14 A2 Cycles Max. contact load 2 1 0.5 0.3 0.2 0.1 0 50 100 150 Voltage [V] 200 250 Dimensions [mm] 22 NC 12 21 COM 11 220-240 VU TS35 93 45 RELAYS 48 24 NO 14 A1 A2 14 3,4 72 Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01a.12 | 13 Interface relays 14 mm CINT-62 Interface module with 2 mechanical change-over output contacts, DIN rail mounting Types: CINT-62/UC24V Standard interface module, 1 change-over contact Cage clamp terminal Control voltage UC 24 V, 50/60 Hz Green LED for status indication Max. contact load 8 A / 250 V AC-1 Contact Data Type Material Rated current Inrush current max. (20 ms) Switching voltage AC-1 max. AC load max. DC load max. Recommended min. contact load micro disconnection Ag Ni +5μ Au 8A 15 A 250 V 2000 VA see Fig. 2 5 mA / 5 V Control input Vn = Operating voltage range Typical input current Nominal power consumption UC 24 V 16.8 … 30 V 20 mA 480 mW RELAY A1 Fig. 1 AC voltage endurance 107 AC-1 Cycles 106 -40 … +70 °C / -40 … +85 °C 5 ms 10 ms ≥ 107 / ≥ 105 operations stranded wire 0.5 … 1.5 mm2 IP 20 any Polyamid 105 104 0 1 2 3 4 5 Switching current [A] 6 7 8 Fig. 2 DC load limit curve 10 8 DC-1 5 CINT-62/UC24V CINT-BR8/5 (5 pieces x 8 pin) CINT5-BEZ/18 (18 pieces) CINT-R22/DC24V Current [A] Accessories Plug-in bridges: Label plate: Replacement relay for CINT-62: 22 21 24 SOCKET Standard types UC 24 (AC/DC): 12 11 14 A2 Insulation Pulse (1.2 / 50 us / Dielectric strength (V rms, 1 minute) Contact / coil 6 kV / 4 kV Contact / contact 4 kV / 2 kV Contact open 1.5 kV / 1 kV General Specifications Ambient temperature operation / storage Typical response time @ Vn Typical release time @ Vn Service life mech. / elec. Cond. cross section spring cage Ingress protection rating Mounting position Housing material Connection diagram 2 1 0.5 0.3 0.2 0.1 0 50 100 150 Voltage [V] 200 250 Dimensions [mm] 22 NC 12 21 COM 11 220-240 VU TS35 93 45 RELAYS 48 24 NO 14 A1 A2 14 3,4 72 Technical approvals, conformities See table on page 53. 14 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Interface relays 14 mm CINT-63 Relays Interface module with 2 mechanical change-over output contacts, DIN rail mounting Types: CINT-63/UC24V Standard interface module, 1 change-over contact Cage clamp terminal Control voltage UC 24 V, 50/60 Hz Green LED for status indication Contact Data Type micro disconnection MaterialAg Ni Rated current 8A Inrush current max. (20 ms) 15 A Switching voltage AC-1 max. 250 V AC load max. 2000 VA DC load max. see Fig. 2 Recommended min. contact load 10 mA / 24 V Control input Vn = Operating voltage range Typical input current Nominal power consumption UC 24 V 16.8 … 30 V 20 mA 480 mW Insulation Pulse (1.2 / 50 us / Dielectric strength (V rms, 1 minute) Contact / coil 6 kV / 4 kV Contact / contact 4 kV / 2 kV Contact open 1.5 kV / 1 kV General Specifications Ambient temperature operation / storage Typical response time @ Vn Typical release time @ Vn Service life mech. / elec. Cond. cross section cage clamp terminal Ingress protection rating Mounting position Housing material 1 8 A / 250 V AC-1 -40 … +70 °C / -40 … +85 °C 5 ms 10 ms ≥ 107 / ≥ 105 operations stranded wire 0.5 … 1.5 mm2 IP 20 any Polyamid Connection diagram RELAY A1 SOCKET Fig. 1 AC voltage endurance 107 AC-1 106 105 104 0 1 2 3 4 5 Switching current [A] 6 7 8 Fig. 2 DC load limit curve 10 8 DC-1 5 CINT-63/UC24 V CINT-BR8/5 (5 pieces x 8 pin) CINT5-BEZ/18 (18 pieces) CINT-R23/DC24V Current [A] Accessories Plug-in bridges: Label plate: Replacement relay for CINT-63: 22 21 24 A2 Standard types UC 24 (AC/DC): 12 11 14 Cycles Max. contact load 2 1 0.5 0.3 0.2 0.1 0 50 100 150 Voltage [V] 200 250 Dimensions [mm] 22 NC 12 21 COM 11 220-240 VU TS35 93 45 RELAYS 48 24 NO 14 A1 A2 14 3,4 72 Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01a.12 | 15 Signal relays C203.06R Interface module with 2 mechanical change-over twin contacts, DIN rail mounting Types: 203.06R/…V Standard interface module, 2 separate change-over contacts Screw terminals Control voltage UC 24 or 36 V, 50/60 Hz LED status indicator for each channel Sealed relays built in Also suitable for panel mounting 2 x M4 Max. contact load 2 A / 30 V DC-1 Contact Data Type Material Rated current Switching voltage AC-1 max. AC load max. DC load max. Recommended min. contact load twin contacts Ag + Au 2A 125 V 100 VA see Fig. 2 10 μA / 10 mV Connection diagram A1 A1 A2 1 2 1 11 12 14 UC 24 V 16.8 … 30 V 18 mA 220 mW UC 36 V 25.2 … 45 V 9 mA 330 mW 2 11 12 14 Fig. 1 DC voltage endurance 106 Insulation Contact / Coil 2.5 kVrms 1 minute General Specifications Ambient temperature operation / storage Typical response time @ Vn Typical release time @ Vn Service life mech. / elec. Cond. cross section screw terminal Ingress protection rating Max. screw torque Mounting position Housing material Weight -40 … +70 °C / -40 … +85 °C 10 ms 20 ms ≥ 107 / ≥ 10 5 operations stranded wire 2.5 mm2, 2 x 1.5 mm2 IP 20 0.4 Nm any Lexan 80 g DC-1 30V Cycles Control input Vn = Operating voltage range Typical input current Nominal power consumption (per channel) 105 0 0.2 0.4 0.6 0.8 1 1.2 1.4 Switching current [A] 1.6 1.8 2 Fig. 2 DC load limit curve DC-1 2 Standard types C203.06R/UC…V "…" Enter the voltage for full type designation Accessories Label plate: 1 Current [A] UC (AC DC): 24, 36 V 0.5 0.3 BZS-DIN17.5 0.2 0.1 0 50 100 150 Voltage [ V ] Dimensions [mm] 4,2 17,5 2,5 TS 35 75 LABEL 5 64 Technical approvals, conformities See table on page 53. 16 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Power relays RIC20-… Relays 20 A, AC/DC control voltage, silent operation, DIN rail mounting according to DIN 43 880 Type: RIC20-xxx/…V Hum-free installation contactor, 2 contacts, 2 NO, 1 NO-1 NC, 2 NC types available 4 kW / 230 V AC-1, 0.5 A / 220 V DC-1 10 mA / 24 V Contacts MaterialAgNi Rated current 20 A Inrush current max. (100 ms) 50 A Switching voltage AC-1 max. 400 V AC load max. AC-1, AC-7a 4 kW / 230 V AC-3 1.3 kW /230 V (NO contact only) DC load max. see Fig. 1 Control input Vn = Operating voltage range [V] Typ. pic up voltage [V] Typ. release voltage [V] Power consumption [W] Inductive turn-off voltage Surge immunity EN 61000-4-5 UC 24 V 20.4 … 26.4 17 7 ≤ 2.5 None 2 kV Insulation Rated insulation voltage Rated impulse withstand voltage Min. clearance of open contact 230 V 4 kV 3.6 mm General Specifications Ambient temperature storage operation, Spacer after 2 contactors side by side operation, Spacer after 3 contactors side by side Pick-up time Release time Mechanical life AC voltage endurance at rated load AC-3, AC-7b DC voltage endurance at rated load DC-1 Operating frequency at rated load DC-1 Operating frequency at rated load AC-1 Conductor cross section coil /contacts Max. Screw torque coil / contacts Ingress protection rating Weight -30 … +80 °C -5 … +55 °C -5 … +40 °C 15 … 45 ms 20 … 50 ms ≥ 3 x 106 operations ≥ 3 x 105 operations 105 operations ≤ 300 operations / h ≤ 600 operations / h Stranded wire 2.5 mm2 / 6 mm2 0.6 Nm / 1.2 Nm IP 20 140 g UC 36 V 30.6 … 39.6 25 11 ≤ 2.5 None 2 kV UC 230 V 195 … 253 160 70 ≤ 2.5 None 2 kV 1 Connection diagram 1A13 1 A1 R1 R1 A1 R3 2A24 2 A2 R2 R2 A2 R4 2x NO RIC20-200 1x NO + 1x NC RIC20-110 2 x NC RIC20 -020 Coil circuit A1 U A2 Fig. 1 DC load limit curve DC-1 DC-1 DC-3 DC-5 20 10 5 Current [A] Rated operational power Recommended minimum contact load 2 1 0.5 0.2 0.1 0.05 0 50 100 150 Voltage [ V ] 200 250 Standard types Accessories Auxiliary contact bloc: Sealing cover: Spacer: RIC-AUX… RIC25, 40, 63 RIC-SEAL20 RIC-DIST Samples of lamp loads Incandescent lamps 230 V / 100 W Fluorescent lamps not corrected 230 V / 36 W Fluorescent lamps electronic ballast units 36 W Number of lamps 20 17 15 Dimensions [mm] *Option: Sealing cover Type: RIC-SEAL 20 1.5* 17,5 Mounting information If multiple contactors are mounted side by side, spacers (RIC DIST) have to be inserted for the purpose of heat dissipation. Example: Ambient temperature up to 40°C: 1 spacer after 3 RIC // 40…55°C: 1 spacer after 2 RIC. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. 45 RIC20-200/UC …V RIC20-110/UC …V RIC20-020/UC …V TS 35 "…" Enter the voltage for full type designation 2NO: 1NO + 1NC: 2NC: 85 UC (AC/DC) 50/60 Hz: 24, 36, 230 V 5 44 (45.5* ) 16.5 Technical approvals, conformities See table on page 53. Railway/01a.12 | 17 Power relays RIC25-… 25 A, AC/DC control voltage, silent operation DIN Rail mounting according to DIN 43 880 Type: RIC25-xxx/…V Hum-free installation contactor, 4 contacts, 4 NO, 4 NC, 2 NO-2 NC types available Rated operational power AC-1Single phase: 5.4 kW/230 V, 0.5 A/220 V DC-1 3 phase 230 V: 9 kW 3 phase 400 V: 16 kW Recommended minimum contact load 10 mA / 24 V Contacts MaterialAgNi Rated current 25 A Inrush current max. (100 ms) 50 A Switching voltage AC-1 max. 400 V AC load max. AC-1, AC-7a 4 kW / 230 V AC-3 2.2 kW /230 V, 4 kW / 400 V DC load max. see Fig. 1 Control input Vn = Operating voltage range [V] Typ. pic up voltage [V] Typ. release voltage [V] Power consumption [W] Inductive turn-off voltage Surge immunity EN 61000-4-5 UC 24 V 20.4 … 26.4 17 7 ≤3 None 2 kV Insulation Rated insulation voltage Rated impulse withstand voltage Min. clearance of open contact 440 V 4 KV 3.6 mm General Specifications Ambient temperature storage operation, Spacer after 2 contactors side by side operation, Spacer after 3 contactors side by side Pick-up time Release time Mechanical life AC voltage endurance at rated load AC-3, AC-7b DC voltage endurance at rated load DC-1 Operating frequency at rated load DC-1 Operating frequency at rated load AC-1, AC-3 Conductor cross section coil / contacts terminals Max. Screw torque coil / contacts Ingress protection rating Weight -30 … +80 °C -5 … +55 °C -5 … +40 °C 15 … 45 ms 20 … 70 ms ≥ 3 x 106 operations ≥ 5 x 105 operations 105 operations ≤ 300 operations / h ≤ 600 operations / h Stranded wire 2.5 mm2 / 6 mm2 0.6 Nm / 1.2 Nm IP 20 270 g UC 36 V 30.6 … 39.6 25 11 ≤3 None 2 kV Connection diagram UC 230 V 195 … 253 160 70 ≤3 None 2 kV 1 3 A1 5 7 R1 R3 A1 R5 R7 2 4 A2 6 8 4x NO: RIC25-400 R2 R4 A2 R6 R8 4x NC: RIC25-040 1 R1 A1 R3 3 2 R2 A2 R4 4 2x NO + 2x NC: RIC25-220 Coil circuit A1 U A2 Fig. 1 DC load limit curve DC-1 25 DC-1 DC-3 DC-5 15 10 Current [A] 5 2 1 0.5 0.2 0.1 0 50 100 150 Voltage [ V ] 200 250 Standard types RIC25-400/UC…V "…" Enter the voltage for full type designation 2NO + 2NC: 4NC: RIC25-220/UC…V RIC25-040/UC…V RIC-AUX… RIC-SEAL25 RIC-DIST Samples of lamp loads Incandescent lamps 230 V/ 100 W Fluorescent lamps not corrected 230 V/ 36 W Fluorescent lamps electronic ballast units 36 W Number of lamps 20 20 20 Mounting information If multiple contactors are mounted side by side, spacers (RIC DIST) have to be inserted for the purpose of heat dissipation. Example: Ambient temperature up to 40°C: 1 spacer after 3 RIC // 40…55°C: 1 spacer after 2 RIC. 18 | Railway/01a.12 *Option: Sealing cover Type: RIC-SEAL25 85 Accessories Auxillary contact bloc: Sealing cover: Spacer: Dimensions [mm] 45 4NO: TS 35 UC (AC/DC) 50/60 Hz: 24, 36, 230 V 1.5* 35 5 44 ( 45.5*) 16.5 Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Time Relays 2. Time Relays ✪ TF-60 Setting of long times 2 The TF 60 time setting methode permits short examination of long delay time settings. Elapsing times of hours can be monitored in the sec. range. Example for a delay time of 38h: 1.Set range switch to 60sec 2.Set 38sec on the potentiometer (e.g. check 38sec by chronometer) 3.Set range switch to 60h The delay time now amounts to 38h. ApplicationTypes Functions* t min. – max. Output contacts Time relay with mechanical CO output contact CIM1R E, A, W, N, K, B, B1, S, LS 50 ms – 60 h✪ Time relay with AC solide-state output CIM12R E, A, W, N, K, B, B1, S, LS 50 ms – 60 h✪ 2 A 250 V Time relay with DC solide-state output CIM13R E, A, W, N, K, B, B1, S, LS 50 ms – 60 h✪ 5 A 24 VD Time relay with mechanical CO output contact CIM2R E, A, L, M, B2, G, H 50 ms – 60 h✪ Time relay with AC solide-state output CIM22R E, A, L, M, B2, G, H 50 ms – 60 h✪ 2A 250V Time relay with AC solide-state output CIM23R E, A, L, M, B2, G, H 50 ms – 60 h✪ 5A 24VD Time relay with mechanical CO output contact CIM3R F, Q, G, H, I, P 50 ms – 60 h✪ Time relay with AC solide-state output CIM32R F, Q, G, H, I, P 50 ms – 60 h✪ 2A 250V Time relay with DC solide-state output CIM33R F, Q, G, H, I, P 50 ms – 60 h✪ 5 A 24 VD Modular time relay with power CO output contacts CT32.31 E, A, W, N, K, B, B1 0.15 s – 60 min 10 A Modular time relay with 3 twin CO output contacts CT32.32 E, A, W, N, K, B, B1 0.15 s – 60 min 6 A Modular time relay with power CO output contacts CT33.31 E, A, F, W, N, Q, K, L, B, B1, G, H 30 ms – 60 h✪ 10 A Modular time relay with 3 twin CO output contacts CT33.32 E, A, F, W, N, Q, K, L, B, B1, G, H 30 ms – 60 h✪ 6 A Modular time relay with power CO output contacts CT36.31 I, P2x 50 ms – 60 h✪ 10 A Modular time relay with 3 twin CO output contactsCT36.32 I, P2x 50 ms – 60 h✪ 6 A *Function diagrams: refer to page 20 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Design 16 A 250 V 16 A 250 V 16A 250V Railway/01a.12 | 19 Time functions Delay functions E Shot timing modes On delay t A S R S R on S OFF R off with delay S R S R on with delay (t1) S OFF R off with delay (t2) Off delay t F S R S R on with delay S OFF R off On and off delay t1 t2 Puls shaping K Puls shaping S R S (pulse or continuous contact) R on for t S no influence on R and t Pulse shaping, retrigger (subsequ.time operation from 0) t M S R S (pulse or continuous contact) R on for t S on for t = t RESET S R S OFF R on for t S no influence on R and t Puls shaping t Delayed pulse G H S R t2 S (pulse or continuous contact) R after t1 on for t2 S no influence on R and t On delay single shot t1 S R t2 S R after t1 on for t2 S OFF R off Special functions Y X1 t S on for t OFF on with delay for t S OFF off S R S R on S OFF R off and starts t S R restart only after t S Restart delay t t Stop/Reset t STOP S STOP interrupts t (t-addition) t RESET S RESET reset t t restarts immediately 20 | Railway/01a.12 One shot trailing edge N t S R S OFF R on for t S on for t R off One shot leading and trailing edge O t1 t2 S R S R on for t1 S OFF R on for t2 S OFF off for t1 R off S R S R on/off periodically according to t S OFF R off Blinker, pulse start B t t t Blinker, pulse start, trailing pulse B1 S R t t t S R on/off periodically according to t S OFF: last pulse = t Blinker, interval start B2 t S R t t S R after t on/off periodically according to t S OFF R off Repeat cycle timer, pulse start I t1 t2 t1 S R S R on/off periodically according to t1 and t2 S OFF R off Repeat cycle timer, interval start P t1 t2 t1 S R C55, CT1: t2 t1 S R after t1 (t2) on/off periodically according to t2 and t1 S OFF R off Special functions Star-delta timer t t S R on for t S OFF R off (pulse clipping) Repeat cycle timer On delay single shot t1 S R Blinker functions t L One shot leading edge W T t is stopped R on/off Test Step-on / Step-off switch S S R LS S R on/off Step-switching (staircase lighting timer), with time lapse t t S R S R on and starts t S on for t R off S =Triggering R = Output circuit = switches… ON OFF This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Multifunction Timer, DIN Rail mounting CIM1R Time relay with mechanical change-over output contact 8 time functions + stepping function, ON-OFF switch, 50 ms … 60 h Type: CIM1R/UC24-240V Sophisticated multifunction time relay, 1 change-over power contact with zero crossing switching (50/60 Hz), 8 time functions, stepping function and service function ON/OFF, time ranges: 50 ms … 60 h, multifunction LED state indicator, suitable for any time-control application and also staircase lighting, Light-switch neon lamp current absorption on input B1, Manual switching function for maintenance, emergency, etc., 16.6 Hz power supply applications. Railway version available. Maximum contact load Recommended minimum contact load 16 A / 250 V AC-1 10 mA / 10 V Time functions and related connection diagrams (Function diagrams: refer to page 20) The functions are selectable by rotary switch LED function table: NO Short blinking OFF YES Long blinking ON YES Time data 7 partial time ranges, tmax (rotary switch) Fine adjustment range (rotary knob) Time range tolerance Repetition accuracy Response time, power on, on A1 Min. trigger pulse on B1 Reset time B1 (AC/DC) Voltage failure buffering (50 / 60 Hz) 0.6, 6, 60 s / 6, 60 min / 6, 60 h tmin … tmax, 0.5 … 6 tmin: -5 % … +0 % / tmax: -0 % … +5 % ± 0.1 % or DC: 2 ms / AC: 10 ms ≤ 45 ms 20 ms (AC / DC) ≤ 40 ms ≥ 20 ms Contacts Type Rated operational current at 40 °C / 60 °C Max. inrush current (10 ms) Max. switching voltage AC-1 Max. AC load AC-1 (Fig.1) Max. DC load DC-1 AgNi / 1 CO, micro disconnection 16 A / 13 A 30 A 250 V 4 kVA see Fig. 2 Insulation Test voltage open contact Test voltage between contacts and control input General Specifications Ambient temperature storage / operation Mechanical life of contact Conductor cross section Ingress protection rating Max. Screw torque Housing material Weight UC 24-240 V (UC = AC/DC) UC 16.8 … 250 V approx. 0.5 W 16 … 63 Hz ≤ 0.5 mA ≤ 10 mA 13 / 15 V 107 AC-1 2 106 105 0 2 4 6 8 10 Switching current [A] 12 14 16 Fig. 2 DC load limit curve 20 16 10 DC-1 5 2 1 0.5 0.2 0.1 0 50 100 150 200 Voltage [V] 1 kVrms 1 minute 2.5 kVrms 1 minute 250 300 Dimensions [mm] -40 … +85 °C / -40 … +70 °C 30 x 106 operations Stranded wire 2.5 mm2, 2 x 1.5 mm2 IP 20 0.4 Nm Lexan 70 g Standard types UC (AC/DC) 15…60 Hz Fig. 1 AC voltage endurance CIM1R/UC24-240V 4,2 17,5 5 45 Power supply- and control input Nominal voltage (A1, B1) Operating voltage range Power consumption Frequency range Allowed DC residual current into B1 AC Neon lamp residual current into B1 Trigger threshold voltage on B1, AC / DC Time Relays NO ON TS 35 A1 B1 A2 OFF Continuous ON 75 A1 B1 A2 OFF 2,5 A1 A2 S S Time run Cycles B W S Relay Current [A] E A K N B1 S LS Connection diagram LED 44 20 Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01a.12 | 21 Multifunction Timer, DIN Rail mounting CIM12R Time relay with AC solid-state output 8 time functions and stepping function, ON-OFF switch, 50 ms … 60 h Type: CIMR12R/UC24-240V Sophisticated multifunction time relay, 1 triac output, suitable for high frequency of operations and inductive loads, 8 time functions, stepping function and service function ON/OFF, time ranges: 50 ms … 60 h, multifunction LED state indicator, suitable for any time-control application and also staircase lighting, Light-switch neon lamp current absorption on input B1, manual switching function for maintenance, emergency, etc., 16.6 Hz applications. Railway version available. Maximum contact load Minimum contact load 2 A / 250 V 50 mA Time functions and related connection diagrams (Function diagrams: refer to page 20) The functions are selectable by rotary switch LED function table: A1 B1 A2 Time data 7 partial time ranges, tmax (rotary switch) Fine adjustment range (rotary knob) Time range tolerance Repetition accuracy Response time, power on, on A1 Min. trigger pulse on B1 Reset time B1 (AC/DC) Voltage failure buffering (50 / 60 Hz) OFF NO Continuous ON ON NO Short blinking OFF YES Long blinking ON YES 0.6, 6, 60 s / 6, 60 min / 6, 60 h tmin … tmax, 0.5 … 6 tmin: -5 % … +0 % / tmax: -0 % … +5 % ± 0.1 % or DC: 2 ms / AC: 10 ms ≤ 45 ms 20 ms (AC / DC) ≤ 40 ms ≥ 20 ms Output Type Rated operational current at 40 °C (Fig.1) Max. inrush current (10 ms) Max. switching voltage Max. AC load AC-1 I2t value Leakage current Triac, zero crossing 2A 100 A 250 V 300 VA 78 A2s < 1 mA Power supply- and control input Nominal voltage Operating voltage range Power consumption Frequency range Allowed DC residual current into B1 AC Neon lamp residual current into B1 Trigger threshold voltage on B1, AC / DC UC 24-240 V (UC = AC/DC) UC 16.8 … 250 V approx. 0.5 W 16 … 63 Hz ≤ 0.5 mA ≤ 10 mA 13 / 15 V Insulation Test voltage between output and control input 2.5 kVrms 1 minute General Specifications Ambient temperature storage / operation Conductor cross section Ingress protection rating Max. Screw torque Housing material Weight TRIAC Fig. 1 Output derating curve 2 1 0 0 10 20 30 40 50 Temperature [∞C] 60 70 80 Dimensions [mm] -40 … +85 °C / -40 … +70 °C Stranded wire 2.5 mm2, 2 x 1.5 mm2 IP 20 0.4 Nm Lexan 70 g 45 A1 B1 A2 OFF TS 35 A1 A2 S S Time run 75 B W S Relay Current [A] E A K N B1 S LS Connection diagram LED UC (AC/DC), 15…60 Hz CIM12R/UC24-240V 4,2 17,5 2,5 Standard types 5 44 20 Technical approvals, conformities See table on page 53. 22 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Multifunction Timer, DIN Rail mounting CIM13R Time relay with DC solid-state output 8 time functions and stepping function, ON-OFF switch, 50 ms … 60 h Type: CIM13R/UC24-240V Sophisticated multifunction time relay, 1 transistor output, 8 time functions, stepping function and service function ON/OFF, time ranges from 50 ms … 60 h, multifunction LED state indicator, suitable for any time-control application and also staircase-light control, light-switch neon lamp current absorption on input B1, manual switching function for maintenance, emergency, etc., 16.6 Hz applications. Railway version available. Maximum contact load Recommended minimum contact load 5 A / 30 V 1 mA Time functions and related connection diagrams (Function diagrams: refer to page 20) The functions are selectable by rotary switch LED function table: NO ON NO Short blinking OFF YES Long blinking ON YES 0.6, 6, 60 s / 6, 60 min / 6, 60 h tmin … tmax, 0.5 … 6 tmin: -5 % … +0 % / tmax: -0 % … +5 % ± 0.1 % or DC: 2 ms / AC: 10 ms ≤ 45 ms 20 ms (AC / DC) ≤ 40 ms ≥ 20 ms Output Type Rated operational current at 40 °C (Fig.1) Max. inrush current (10 µs) Max. switching voltage Leakage current MOS FET 5A 40 A 30 V < 10 µA Power supply- and control input Nominal voltage (UC = AC / DC) Operating voltage range Power consumption Frequency range Allowed DC residual current into B1 AC Neon lamp residual current into B1 Trigger threshold voltage on B1, AC / DC UC 24-240 V (UC = AC/DC) UC 16.8 … 250 V approx. 0.5 W 16 … 63 Hz ≤ 0.5 mA ≤ 10 mA 13 / 15 V Insulation Test voltage between output and control input 2.5 kVrms 1 minute General Specifications Ambient temperature storage / operation Conductor cross section Ingress protection rating Max. Screw torque Housing material Weight -40 … +85 °C / -40 … +70 °C Stranded wire 2.5 mm2, 2 x 1.5 mm2 IP 20 0.4 Nm Lexan 70 g MOSFET Fig. 1 Output derating curve 6 2 5 4 3 2 1 0 0 10 30 40 50 Temperature [∞C] 60 70 80 Dimensions [mm] Standard types UC (AC/DC), 15…60 Hz 20 75 Time data 7 partial time ranges, tmax (rotary switch) Fine adjustment range (rotary knob) Time range tolerance Repetition accuracy Response time, power on, on A1 Min. trigger pulse on B1 Reset time B1 (AC/DC) Voltage failure buffering (50 / 60 Hz) Time Relays A1 B1 A2 OFF Continuous ON 45 A1 B1 A2 OFF TS 35 A1 A2 S S Time run CIM13R/UC24-240V 4,2 17,5 2,5 B W S Relay Current [A] E A K N B1 S LS Connection diagram LED 5 44 20 Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01a.12 | 23 Multifunction Timer, DIN Rail mounting CIM2R Time relay with mechanical change-over output contact 7 time functions and 7 time ranges from 50 ms … 60 h Type: CIM2R/UC24-240V Sophisticated multifunction time relay, 1 change-over power contact switching in zero crossing (50/60 Hz), 7 time functions and service function ON/OFF, 7 time ranges from 50 ms to 60 h, multifunction LED state indicator, suitable for any time-control application, light-switch neon lamp current absorption on input B1, manual switching function for maintenance, emergency, etc., 16.6 Hz power supply applications. Railway version available. Maximum contact load Recommended minimum contact load 16 A / 250 V AC-1 10 mA / 10 V Time functions and related connection diagrams (Function diagrams: refer to page 20) The functions are selectable by rotary switch LED function table: OFF NO Continuous ON ON NO Short blinking OFF YES Long blinking ON YES Time data 7 partial time ranges, tmax (rotary switch) Fine adjustment range (rotary knob) Time range tolerance Repetition accuracy Response time, power on, on A1 Min. trigger pulse on B1 Reset time B1 (AC/DC) Voltage failure buffering (50 / 60 Hz) 0.6, 6, 60 s / 6, 60 min / 6, 60 h tmin … tmax, 0.5 … 6 tmin: -5 % … +0 % / tmax: -0 % … +5 % ± 0.1 % or DC: 2 ms / AC: 10 ms ≤ 45 ms 20 ms (AC / DC) ≤ 40 ms ≥ 20 ms Contacts Type Rated operational current at 40 °C / 60 °C Max. inrush current (10 ms) Max. switching voltage AC-1 Max. AC load AC-1 (Fig.1) Max. DC load DC-1 AgNi / 1 CO, micro disconnection 16 A / 13 A 30 A 250 V 4 kVA see Fig. 2 Power supply- and control input Nominal voltage (A1, B1) Operating voltage range Power consumption Frequency range Allowed DC residual current into B1 AC Neon lamp residual current into B1 Trigger threshold voltage on B1, AC / DC Insulation Test voltage open contact Test voltage between contacts and control input General Specifications Ambient temperature storage / operation Mechanical life of contact Conductor cross section Ingress protection rating Max. Screw torque Housing material Weight UC 24-240 V (UC = AC / DC) UC 16.8 … 250 V approx. 0.5 W 16 … 63 Hz ≤ 0.5 mA ≤ 10 mA 13 / 15 V Fig. 1 AC voltage endurance 107 AC-1 106 105 0 2 4 6 8 10 Switching current [A] 12 14 16 Fig. 2 DC load limit curve 20 16 10 DC-1 5 2 1 0.5 0.2 0.1 0 50 100 150 200 Voltage [V] 1 kVrms 1 minute 2.5 kVrms 1 minute 250 300 Dimensions [mm] -40 … +85 °C / -40 … +70 °C 30 x 106 operations Stranded wire 2.5 mm2, 2 x 1.5 mm2 IP 20 0.4 Nm Lexan 70 g 45 A1 B1 A2 OFF TS 35 A1 B1 A2 S 75 A1 A2 S Time run Cycles B2 H S Relay Current [A] E A L M G Connection diagram LED UC (AC/DC) 15…60 Hz CIM2R/UC24-240V 4,2 17,5 2,5 Standard types 5 44 20 Technical approvals, conformities See table on page 53. 24 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Multifunction Timer, DIN Rail mounting CIM22R Time relay with AC solid-state output 7 time functions and 7 time ranges 50 ms … 60 h Type: CIM22R/UC24-240V Sophisticated multifunction time relay, 1 triac output, suitable for high frequency of operations and inductive loads, 7 time functions and service function ON/OFF, 7 time ranges from 50 ms … 60 h, multifunction LED state indicator, suitable for any time-control application light-switch neon lamp current absorption on input B1, manual switching function for maintenance, emergency, etc., 16.6 Hz applications. Railway version available. Maximum contact load Minimum contact load 2 A / 250 V 50 mA Time functions and related connection diagrams (Function diagrams: refer to page 20) The functions are selectable by rotary switch LED function table: Time data 7 partial time ranges, tmax (rotary switch) Fine adjustment range (rotary knob) Time range tolerance Repetition accuracy Response time, power on, on A1 Min. trigger pulse on B1 Reset time B1 (AC/DC) Voltage failure buffering (50 / 60 Hz) OFF NO Continuous ON ON NO Short blinking OFF YES Long blinking ON YES 0.6, 6, 60 s / 6, 60 min / 6, 60 h tmin … tmax, 0.5 … 6 tmin: -5 % … +0 % / tmax: -0 % … +5 % ± 0.1 % or DC: 2 ms / AC: 10 ms ≤ 45 ms 20 ms (AC / DC) ≤ 40 ms ≥ 20 ms Output Type Rated operational current at 40 °C (Fig.1) Max. inrush current (10 ms) Max. switching voltage Max. AC load AC-1 I2t value Leakage current Triac, zero crossing 2A 100 A 250 V 300 VA 78 A2s < 1 mA Power supply- and control input Nominal voltage Operating voltage range Power consumption Frequency range Allowed DC residual current into B1 AC Neon lamp residual current into B1 Trigger threshold voltage on B1, AC / DC UC 24-240 V (UC = AC / DC) UC 16.8 … 250 V approx. 0.5 W 16 … 63 Hz ≤ 0.5 mA ≤ 10 mA 13 / 15 V Insulation Test voltage between output and control input 2.5 kVrms 1 minute General Specifications Ambient temperature storage / operation Conductor cross section Ingress protection rating Max. Screw torque Housing material Weight Time Relays A1 B1 A2 OFF TRIAC Fig. 1 Output derating curve 2 2 1 0 0 10 20 30 40 50 Temperature [∞C] 60 70 80 Dimensions [mm] -40 … +85 °C / -40 … +70 °C Stranded wire 2.5 mm2, 2 x 1.5 mm2 IP 20 0.4 Nm Lexan 70 g 45 A1 B1 A2 S TS 35 A1 A2 S Time run 75 B2 H S Relay Current [A] E A L M G Connection diagram LED UC (AC/DC), 15…60 Hz CIM22R/UC24-240V 4,2 17,5 2,5 Standard types 5 44 20 Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01a.12 | 25 Multifunction Timer, DIN Rail mounting CIM23R Time relay with DC solid-state output 7 time functions and 7 time ranges from 50 ms … 60 h Type: CIM23R/UC24-240V Sophisticated multifunction time relay, 1 transistor output, 7 time functions and service function ON/OFF, 7 time ranges from 50 ms … 60 h, multifunction LED state indicator suitable for any time-control application, light-switch neon lamp current absorption on input B1, manual switching function for maintenance, emergency, etc., 16.6 Hz applications. Railway version available. Maximum contact load Recommended minimum contact load 5 A / 30 V 1 mA Time functions and related connection diagrams (Function diagrams: refer to page 20) The functions are selectable by rotary switch LED function table: A1 B1 A2 Time data 7 partial time ranges, tmax (rotary switch) Fine adjustment range (rotary knob) Time range tolerance Repetition accuracy Response time, power on, on A1 Min. trigger pulse on B1 Reset time B1 (AC/DC) Voltage failure buffering (50 / 60 Hz) NO Continuous ON ON NO Short blinking OFF YES Long blinking ON YES Connection diagram MOSFET 0.6, 6, 60 s / 6, 60 min / 6, 60 h tmin … tmax, 0.5 … 6 tmin: -5 % … +0 % / tmax: -0 % … +5 % ± 0.1 % or DC: 2 ms / AC: 10 ms ≤ 45 ms 20 ms (AC / DC) ≤ 40 ms ≥ 20 ms Output Type Rated operational current at 40 °C (Fig.1)) Max. inrush current (10 µs) Max. switching voltage Leakage current MOS FET 5A 40 A 30 V < 10 µA Power supply- and control input Nominal voltage (UC = AC / DC) Operating voltage range Power consumption Frequency range Allowed DC residual current into B1 AC Neon lamp residual current into B1 Trigger threshold voltage on B1, AC / DC UC 24-240 V (UC = AC / DC) UC 16.8 … 250 V approx. 0.5 W 16 … 63 Hz ≤ 0.5 mA ≤ 10 mA 13 / 15 V Insulation Test voltage between output and control input 2.5 kVrms 1 minute General Specifications Ambient temperature storage / operation Conductor cross section Ingress protection rating Max. Screw torque Housing material Weight -40 … +85 °C / -40 … +70 °C Stranded wire 2.5 mm2, 2 x 1.5 mm2 IP 20 0.4 Nm Lexan 70 g Fig. 1 Output derating curve 6 5 4 3 2 1 0 0 10 30 40 50 Temperature [∞C] 60 70 80 Dimensions [mm] 75 Standard types UC (AC/DC), 15…60 Hz 20 CIM23R/UC24-240V 4,2 17,5 5 45 S A1 B1 A2 Time run OFF TS 35 B2 H A1 A2 S Relay OFF 2,5 A L M G S LED Current [A] E 44 20 Technical approvals, conformities See table on page 53. 26 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Multifunction Timer, DIN Rail mounting CIM3R Time relay with mechanical change-over output contact 6 time functions and service function, 7 time ranges from 50 ms…60 h Type: CIM3R/UC24-240V Sophisticated multifunction time relay, 1 change-over power contact switching in zero crossing (50/60 Hz), 6 time functions and service function ON/OFF, 7 time ranges from 50 ms to 60 h, multifunction LED state indicator, suitable for any time-control application, light-switch neon lamp current absorption on input B1, manual switching function for maintenance, emergency, etc., 16.6 Hz power supply applications. Railway version available. Maximum contact load Recommended minimum contact load 16 A / 250 V AC-1 10 mA / 10 V Time functions and related connection diagrams (Function diagrams: refer to page 20) The functions are selectable by rotary switch LED function table: NO ON NO Short blinking OFF YES Long blinking ON YES Time data 7 partial time ranges, tmax (rotary switch) Fine adjustment range (rotary knob) Time range tolerance Repetition accuracy Response time, power on, on A1 Min. trigger pulse on B1 Reset time B1 (AC/DC) Voltage failure buffering (50 / 60 Hz) 0.6, 6, 60 s / 6, 60 min / 6, 60 h tmin … tmax, 0.5 … 6 tmin: -5 % … +0 % / tmax: -0 % … +5 % ± 0.1 % or DC: 2 ms / AC: 10 ms ≤ 45 ms 20 ms (AC / DC) ≤ 40 ms ≥ 20 ms Contacts Type Rated operational current at 40 °C / 60 °C Max. inrush current (10 ms) Max. switching voltage AC-1 Max. AC load AC-1 (Fig.1) Max. DC load DC-1 AgNi / 1 CO, micro disconnection 16 A / 13 A 30 A 250 V 4 kVA see Fig. 2 Insulation Test voltage open contact Test voltage between contacts and control input General Specifications Ambient temperature storage / operation Mechanical life of contact Conductor cross section Ingress protection rating Max. Screw torque Housing material Weight UC 24-240 V (UC = AC / DC) UC 16.8 … 250 V approx. 0.5 W 16 … 63 Hz ≤ 0.5 mA ≤ 10 mA 13 / 15 V Fig. 1 AC voltage endurance 107 AC-1 2 106 105 0 2 4 6 8 10 Switching current [A] 12 14 16 Fig. 2 DC load limit curve 20 16 10 DC-1 5 2 1 0.5 0.2 0.1 0 50 100 150 200 Voltage [V] 1 kVrms 1 minute 2.5 kVrms 1 minute 250 300 Dimensions [mm] -40 … +85 °C / -40 … +70 °C 30 x 106 operations Stranded wire 2.5 mm2, 2 x 1.5 mm2 IP 20 0.4 Nm Lexan 70 g 45 Power supply- and control input Nominal voltage (A1, B1) Operating voltage range Power consumption Frequency range Allowed DC residual current into B1 AC Neon lamp residual current into B1 Trigger threshold voltage on B1, AC / DC Time Relays OFF Continuous ON TS 35 A1 B1 A2 OFF 75 A1 B1 A2 S Time run Cycles S Relay Current [A] F Q G H I P Connection diagram LED UC (AC/DC) 15…60 Hz CIM3R/UC24-240V 4,2 17,5 2,5 Standard types 5 44 20 Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01a.12 | 27 Multifunction Timer, DIN Rail mounting CIM32R Time relay with AC solid-state output 6 time functions and service function, 7 time ranges from 50 ms…60 h Type: CIM32R/UC24-240V Sophisticated multifunction time relay, 1 triac output, suitable for high frequency of operations and inductive loads, 6 time functions and service function ON/OFF, 7 time ranges from 50 ms … 60 h, multifunction LED state indicator, suitable for any time-control application light-switch neon lamp current absorption on input B1, manual switching function for maintenance, emergency, etc., 16.6 Hz applications. Railway version available. Maximum contact load Minimum contact load 2 A / 250 V 50 mA Time functions and related connection diagrams (Function diagrams: refer to page 20) The functions are selectable by rotary switch Connection diagram F Q G H I P S A1 B1 A2 S A1 B1 A2 LED Relay Time run OFF OFF NO Continuous ON ON NO Short blinking OFF YES Long blinking ON YES Time data 7 partial time ranges, tmax (rotary switch) Fine adjustment range (rotary knob) Time range tolerance Repetition accuracy Response time, power on, on A1 Min. trigger pulse on B1 Reset time B1 (AC/DC) Voltage failure buffering (50 / 60 Hz) 0.6, 6, 60 s / 6, 60 min / 6, 60 h tmin … tmax, 0.5 … 6 tmin: -5 % … +0 % / tmax: -0 % … +5 % ± 0.1 % or DC: 2 ms / AC: 10 ms ≤ 45 ms 20 ms (AC / DC) ≤ 40 ms ≥ 20 ms Output Type Rated operational current at 40 °C (Fig.1) Max. inrush current (10 ms) Max. switching voltage Max. AC load AC-1 I2t value Leakage current Triac, zero crossing 2A 100 A 250 V 300 VA 78 A2s < 1 mA Power supply- and control input Nominal voltage Operating voltage range Power consumption Frequency range Allowed DC residual current into B1 AC Neon lamp residual current into B1 Trigger threshold voltage on B1, AC / DC UC 24-240 V (UC = AC / DC) UC 16.8 … 250 V approx. 0.5 W 16 … 63 Hz ≤ 0.5 mA ≤ 10 mA 13 / 15 V Insulation Test voltage between output and control input 2.5 kVrms 1 minute TRIAC Fig. 1 Output derating curve 2 Current [A] LED function table: 1 0 0 10 20 30 40 50 Temperature [∞C] 60 70 80 45 75 -40 … +85 °C / -40 … +70 °C Stranded wire 2.5 mm2, 2 x 1.5 mm2 IP 20 0.4 Nm Lexan 70 g TS 35 Dimensions [mm] General Specifications Ambient temperature storage / operation Conductor cross section Ingress protection rating Max. Screw torque Housing material Weight UC (AC/DC), 15…60 Hz CIM32R/UC24-240V 4,2 17,5 2,5 Standard types 5 44 20 Technical approvals, conformities See table on page 53. 28 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Multifunction Timer, DIN Rail mounting CIM33R Time relay with DC solid-state output 6 time functions and service function, 7 time ranges from 50 ms…60 h Type: CIM33/UC24-240V Sophisticated multifunction time relay, 1 transistor output, 6 time functions and service function ON/OFF, 7 time ranges from 50 ms … 60 h, Multifunction LED state indicator, suitable for any time-control application, light-switch neon lamp current absorption on input B1, manual switching function for maintenance emergency, etc., 16.6 Hz applications. Railway version available. Maximum contact load Recommended minimum contact load 5 A / 30 V 1 mA Time functions and related connection diagrams (Function diagrams: refer to page 20) The functions are selectable by rotary switch LED function table: Continuous ON ON NO Short blinking OFF YES Long blinking ON YES Connection diagram MOSFET 0.6, 6, 60 s / 6, 60 min / 6, 60 h tmin … tmax, 0.5 … 6 tmin: -5 % … +0 % / tmax: -0 % … +5 % ± 0.1 % or DC: 2 ms / AC: 10 ms ≤ 45 ms 20 ms (AC / DC) ≤ 40 ms ≥ 20 ms Output Type Rated operational current at 40 °C (Fig.1) Max. inrush current (10 µs) Max. switching voltage Leakage current MOS FET 5A 40 A 30 V < 10 µA Power supply- and control input Nominal voltage Operating voltage range Power consumption Frequency range Allowed DC residual current into B1 AC Neon lamp residual current into B1 Trigger threshold voltage on B1, AC / DC UC 24-240 V (UC = AC / DC) UC 16.8 … 250 V approx. 0.5 W 16 … 63 Hz ≤ 0.5 mA ≤ 10 mA 13 / 15 V Insulation Test voltage between output and control input 2.5 kVrms 1 minute General Specifications Ambient temperature storage / operation Conductor cross section Ingress protection rating Max. Screw torque Housing material Weight -40 … +85 °C / -40 … +70 °C Stranded wire 2.5 mm2, 2 x 1.5 mm2 IP 20 0.4 Nm Lexan 70 g Fig. 1 Output derating curve 6 2 5 4 3 2 1 0 0 10 20 30 40 50 Temperature [∞C] 60 70 80 Dimensions [mm] 75 Standard types UC (AC/DC), 15…60 Hz Time Relays Time data 7 partial time ranges, tmax (rotary switch) Fine adjustment range (rotary knob) Time range tolerance Repetition accuracy Response time, power on, on A1 Min. trigger pulse on B1 Reset time B1 (AC/DC) Voltage failure buffering (50 / 60 Hz) NO CIM33R/UC24-240V 4,2 17,5 5 45 A1 B1 A2 Time run OFF TS 35 S A1 B1 A2 Relay OFF 2,5 H I P S LED Current [A] F Q G 44 20 Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01a.12 | 29 CT-System Plug-in timer modules (to combine with industrial relays) CT32R, CT33R, CT36R Type CT32R, CT33R, CT36R, /…V Plug-in time modules for sockets with module slot in combination with plug-in relays. Power supply and control voltages 24 … 240 V. Time ranges 30 ms up to 60 h. LED output state indicator. Time functions and related connection diagrams (Function diagrams: refer to page 20) CT32R (Universal) CT33R (Universal) CT36R (Repeat cycle timer) Time data Type CT32RCT33RCT36R Partial time ranges, tmax 1.5, 6, 15, 60 /s /min 150, 600 ms 2 x 600 ms 1.5, 6, 15, 60 /s /min /h 2 x 6, 60 /s /min /h Min. time tmin 0.15 s 30 ms 2 x 50 ms Fine adj. range tmin … 1 … 1 0 0.2 … 1 2 x 5 … 60 Time range tolerance -25 … 0 % -25 … 0 % -25 … 0 % 0 … 25 % 0 … 25 % 0 … 25 % Repetition accuracy ± 0.2 % or 20 ms ± 0.2 % or 20 ms ± 0.2 % or 20 ms Temperature drift of time 0.1 % / K 0.1 % / K 0.1 % / K Min. trigger pulse width B1 ≥ 30 ms ≥ 30 ms – Reset time pow. supply ≤ 150 ms ≤ 150 ms ≤ 150 ms Voltage failure buffering ≥ 20 ms ≥ 20 ms ≥ 20 ms Output data Nominal voltage Type Rated operational current On-state resistance Leakage current UC 24–48 V Solid state 150 mA ≤ 25 Ω ≤ 150 µA Power supply and control input (UC = AC/ DC) Type Nominal voltage Operating voltage range Input B1 inactive Supply current CT32RCT33RCT36R UC 24 – 48 V UC 24 – 48 V UC 24 – 48 V 16.8 … 60 V 16.8 … 60 V 16.8 … 60 V ≤ 9 V ≤ 9 V – 5 … 11 mA 5 … 11 mA 6 … 12 mA General Specification Ambient temperature storage / operation Ingress protection rating Housing material Weight -40 … +85 °C / -40 … +70 °C IP 40 when plugged in Lexan 25 g Standard types CT32R/UC24-48V CT33R/UC24-48V CT36R/UC24-48V Dimensions [mm] Remark:This module is part of several ready for connection units consisting of socket, relay and module. A wide range of suitable relays are available. 16 75 4 38 4 20 54 Technical approvals, conformities See table on page 53. 30 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Power Relay Plug-in timer set CT-System Control Relay CT32.31R, CT33.31R, CT36.31R CT32.32R, CT33.32R, CT36.32R Timer Delay Relay-Set Relay, Module and Socket Set delivery includes: •Relay •Module •Front cover •Socket •Retaining clip Relay data: See page 4/5 C31D/R C32D/R Universal Power Relay 10A 10A 250VA 6A 250VA MIN 50mA 10V 10mA 5V 9 8 7 5 3 4 R R S + CT32R Universal-Timer 7 functions, voltage controlled, time lapse display, blinking. Seismic approved. Function /Triggering 0,15 s-60 min H 0,15-1,5s… 6-60min ANKB1 W B CT33R Universal-Timer 12 functions, voltage controlled, time lapse display, blinking, high setting accuracy by dial graduation 1:5. Timer Range Function /Triggering W H B E A N L F K G B1 Q t 2 = t1 G H t 2 = 0,5s 30ms-60 h H 30-150ms… 12-60 h CT36R Universal-Taktgeber Pulse or pause start. t1/ t2 separately settable. Time lapse display t1/ t2. Function /Triggering 2 x 50ms-60 h H 2x50-600ms… 5-60h + Set Order-Nr.: Set Order-Nr.: CT32.31R/…V CT32.32R/…V Delivery includes: • Relay C32D/R DC…V • Module CT32R/UC24-48V • Front cover FS-C • Socket C12B0 • Retaining clip HF-32 Set Order-Nr.: Set Order-Nr.: CT33.31R/…V CT33.32R/…V DC 24, 36V DC 24, 36V Delivery includes: • Relay C31D/R DC…V • Module CT33R/UC24-48V • Front cover FS-C • Socket C12B0 • Retaining clip HF-32 Delivery includes: • Relay C32D/R DC…V • Module CT33R/UC24-48V • Front cover FS-C • Socket C12B0 • Retaining clip HF-32 Set Order-Nr.: Set Order-Nr.: CT36.31R/…V CT36.32R/…V Delivery includes: • Relay C31D/R DC…V • Module CT36R/UC24-48V • Front cover FS-C • Socket C12B0 • Retaining clip HF-32 2 DC 24, 36V Delivery includes: • Relay C31D/R DC…V • Module CT32R/UC24-48V • Front cover FS-C • Socket C12B0 • Retaining clip HF-32 DC 24, 36V Timer Range A2 35 25 15 B1 A1 10 11 6 1 12 2 + + DC 24, 36V Timer Range E S A2 35 25 15 B1 A1 10 11 6 1 12 2 TIMER-MODUL A2 A1 A2 B1 A1 A2 B1 A1 + I P 38 36 28 26 18 16 Triggering S F Q 38 36 28 26 18 16 TIMER-MODUL Timer-Modul Function (see page 30) The control relay with highest switching reliablility for control and signal circuits ranging from 10mA 5V. MAX 9 8 7 5 3 4 E Relay with 3 twin contacts 6A Time Relays Relay data’s see: Relay C31; C32 with 3 power change-overcontacts this is the robust relay for AC and DC circuits ranging from 50mA 10V. DC 24, 36V Delivery includes: • Relay C32D/R DC…V • Module CT36R/UC24-48V • Front cover FS-C • Socket C12B0 • Retaining clip HF-32 Dimensions [mm] See page 30. Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01a.12 | 31 Notes 32 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Application Types Monitoring Voltage monitoring, AC / DC single phase MRU11R 0 … AC 480 V / DC 690 V Voltage monitoring, AC / DC three phase MRU32R 0 … AC 480 V / DC 690 V Current monitoring, AC / DC single phase MRI11R 0 … 5 A Current monitoring, AC / DC three phase MRI32R 0 … 5 A Multifunction monitoring, AC / DC single phase MRM11R U, I, P, f, cosφ Multifunction monitoring, AC / DC three phase MRM32R U, I, P, f, cosφ DC Voltage monitoring CT524.31R 0 … 30 V DC Voltage monitoring CT524.32R 0 … 30 V DC Current monitoring CT512.31R 0 … 200 mA DC Current monitoring CT512.32R 0 … 200 mA DC Current monitoring CT515.31R 0 … 2 A DC Current monitoring CT515.32R 0 … 2 A DC Current monitoring CT516.31R 0 … 6 A DC Current monitoring CT516.32R 0 … 6 A Isolation monitoring, DC networks ESU-D2 1 … 50 kΩ This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Monitoring range Output contacts Design 3 50 mm Railway/01a.12 | Monitoring Relays 3. Monitoring Relays 33 1-phase monitoring MRU11R Voltage monitoring relay AC/DC, single phase DIN Rail mounting according to DIN 43 880 Type: MRU11R/…V Voltage monitoring relay with over- and under voltage thresholds up to 690 V. Alarm delay setting. Alarm LED. Display for voltmeter function, alarm signal and interactive parameter setting. 1 change-over alarm contact 6 A 250 V. Comfortable parameter setting. Monitoring function LIMIT 1 HYST 1 LIMIT 1 HYST INPUT INPUT HYST LIMIT2 HYST LIMIT1 AL AL t OFF ok ok ye fail t OFF ok al rd alarm t ON t OFF ok al Alarm delay: AL t ON t OFF Connection diagram N ok al L U– U– al t OFF, t ON LOAD t ON Measuring circuit data Over/under voltage setting ranges AC / DC Frequency Resolution Accuracy Input resistance 0 … 480 V / 0 … 690 V DC, AC 16 … 100 Hz 100 mV 2 % ±1 digit 1 MΩ Time data Alarm delay setting time Reset time setting range Voltage failure buffering 0.1 … 999.9 s 0.1 … 999.9 s ca. 30 ms Contacts Type / Material Rated operational current Max. inrush current Max. switching voltage Max. AC load AC-1 (Fig.1) Max. DC load DC-1, 24 V / 220 V (Fig.2) Recommended min. contact load 1 CO / AgNi 0.15 6A 15 A 250 V 1250 VA 120 W / 25 W 10 mA / 10 V Power supply Nominal voltage AC/DC Operating voltage range AC frequency Power consumption UC12-48V 12 … 48 V 10 … 57 V 16 … 63 Hz 2 W / 3 VA U+ AL 15 16 18 A1 A2 Fig. 1 AC voltage enduranc Cycles 107 AC-1 106 105 0 1 2 3 4 Switching current [A] 5 6 Fig. 2 DC load limit curve 10 DC-1 6 5 UC110-240V 110 … 240 V 85 … 250 V 16 … 63 Hz 2 W / 3 VA Current [A] t ON gn INPUT 2 1 0.5 0.3 Insulation Test voltage open - contact Test voltage measuring input - contacts Test voltage measuring input - power supply 0.2 1 kVrms 1 minute 4 kVrms 1 minute 4 kVrms 1 minute 0.1 0 50 100 150 200 Voltage [V] 250 300 Dimensions [mm] General specifications Ambient temperature storage /operation Mechanical life of contacts Conductor cross section Ingress protection rating Max. screw torque Housing material Weight -40 … +85 °C / -25 … +60 °C 30 x 106 operations Stranded wire 2.5 mm2, 2 x 1.5 mm2 IP20 0.4 Nm Lexan EXL 9330 130 g Standard types AC/DC 12-48 V, 15…60 Hz AC/DC 110-240 V, 15…60 Hz MRU11R/UC12-48V MRU11R/UC110-240V Technical approvals, conformities See table on page 53. 34 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. 3-phase monitoring MRU32R Voltage monitoring relay AC/DC, three phase DIN Rail mounting according to DIN 43 880 Type: MRU32R/…V Voltage monitoring relay with over- and under voltage thresholds up to 690 V. Alarm delay setting. Alarm LED. Display for voltmeter function, alarm signal and interactive parameter setting. 2 change-over alarm contacts 6 A 250 V. Comfortable parameter setting. Monitoring function LIMIT 1 HYST 1 LIMIT 1 HYST AL AL t ON t OFF ok ok ye fail t OFF ok al rd alarm t ON t OFF ok al Alarm delay: AL t ON t OFF Connection diagram N L1 L2 L3 ok al al t OFF, t ON LOAD t ON gn INPUT U– U– U1+ U2+ U3+ AL1 AL2 15 16 18 25 26 28 0 … 480 V / 0 … 690 V DC, AC 16 … 100 Hz 100 mV 2 % ±1 digit 1 MΩ Time data Alarm delay setting time Reset time setting range Voltage failure buffering 0.1 … 999.9 s 0.1 … 999.9 s ca. 30 ms Contacts Type / Material Rated operational current Max. inrush current Max. switching voltage Max. AC load AC-1 (Fig.1) Max. DC load DC-1, 24 V / 220 V (Fig.2) Recommended min. contact load 2 CO / AgNi 0.15 6A 15 A 250 V 1250 VA 120 W / 25 W 10 mA / 10 V Power supply Nominal voltage AC/DC Operating voltage range AC frequency Power consumption UC12-48V 12 … 48 V 10 … 57 V 16 … 63 Hz 2 W / 3 VA A1 A2 Fig. 1 AC voltage enduranc 107 Cycles Measuring circuit data Over/under voltage setting ranges AC / DC Frequency Resolution Accuracy Input resistance AC-1 106 105 0 1 2 3 4 Switching current [A] 5 6 Fig. 2 DC load limit curve 10 DC-1 Current [A] 6 5 UC110-240V 110 … 240 V 85 … 250 V 16 … 63 Hz 2 W / 3 VA 3 2 1 0.5 0.3 0.2 Insulation Test voltage open - contact Test voltage between poles Test voltage measuring input - contacts Test voltage measuring input - power supply 1 kVrms 1 minute 2.5 kVrms 1 minute 4 kVrms 1 minute 4 kVrms 1 minute General specifications Ambient temperature storage /operation Mechanical life of contacts Conductor cross section Ingress protection rating Max. screw torque Housing material Weight -40 … +85 °C / -25 … +60 °C 30 x 106 operations Stranded wire 2.5 mm2, 2 x 1.5 mm2 IP20 0.4 Nm Lexan EXL 9330 130 g 0.1 0 50 100 150 200 Voltage [V] 250 300 Dimensions [mm] Standard types AC/DC 12-48 V, 15…60 Hz AC/DC 110-240 V, 15…60 Hz MRU32R/UC12-48V MRU32R/UC110-240V Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Monitoring Relays HYST LIMIT1 LOAD INPUT HYST LIMIT2 LOAD INPUT Railway/01a.12 | 35 1-phase monitoring MRI11R Current monitoring relay AC/DC, single phase DIN Rail mounting according to DIN 43 880 Type: MRI11R/…V Current monitoring relay with over- and under voltage thresholds up to 5 A. Alarm delay setting. Alarm LED. Display for voltmeter function, alarm signal and interactive parameter setting. 1 change-over alarm contact 6 A 250 V. Comfortable parameter setting. Monitoring function LIMIT 1 HYST 1 LIMIT 1 HYST INPUT INPUT HYST LIMIT2 HYST LIMIT1 AL AL t ON t OFF ok ok ye fail t OFF ok al rd alarm t ON t OFF ok al Alarm delay: AL t ON t OFF Connection diagram N ok al L I– I+ al t OFF, t ON LOAD t ON gn INPUT AL 15 16 18 0…5A DC, AC 16 … 100 Hz 100 mA 2 % ±1 digit 5 mΩ Time data Alarm delay setting time Reset time setting range Voltage failure buffering 0.1 … 999.9 s 0.1 … 999.9 s ca. 30 ms Contacts Type / Material Rated operational current Max. inrush current Max. switching voltage Max. AC load AC-1 (Fig.1) Max. DC load DC-1, 24 V / 220 V (Fig.2) Recommended min. contact load 1 CO / AgNi 0.15 6A 15 A 250 V 1250 VA 120 W / 25 W 10 mA / 10 V Power supply Nominal voltage AC/DC Operating voltage range AC frequency Power consumption UC12-48V 12 … 48 V 10 … 57 V 16 … 63 Hz 2 W / 3 VA A1 A2 Fig. 1 AC voltage enduranc 107 Cycles Measuring circuit data Over/under current setting ranges AC / DC Frequency Resolution Accuracy Input resistance AC-1 106 105 0 1 2 3 4 Switching current [A] 5 6 Fig. 2 DC load limit curve 10 DC-1 UC110-240V 110 … 240 V 85 … 250 V 16 … 63 Hz 2 W / 3 VA Current [A] 6 5 2 1 0.5 0.3 0.2 Insulation Test voltage open - contact Test voltage measuring input - contacts Test voltage measuring input - power supply 1 kVrms 1 minute 4 kVrms 1 minute 4 kVrms 1 minute General specifications Ambient temperature storage /operation Mechanical life of contacts Conductor cross section Ingress protection rating Max. screw torque Housing material Weight -40 … +85 °C / -25 … +60 °C 30 x 106 operations Stranded wire 2.5 mm2, 2 x 1.5 mm2 IP20 0.4 Nm Lexan EXL 9330 130 g 0.1 0 50 100 150 200 Voltage [V] 250 300 Dimensions [mm] Standard types UC 12-48 V (AC/DC), 15…60 Hz UC 110-240 V (AC/DC), 15…60 Hz MRI11R/UC12-48V MRI11R/UC110-240V Technical approvals, conformities See table on page 53. 36 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. 3-phase monitoring MRI32R Current monitoring relay AC/DC, three phase DIN Rail mounting according to DIN 43 880 Type: MRI32R/…V Current monitoring relay with over- and under current thresholds up to 5 A. Alarm delay setting. Alarm LED. Display for voltmeter function, alarm signal and interactive parameter setting. 2 change-over alarm contacts 6 A 250 V. Comfortable parameter setting. Monitoring function LIMIT 1 HYST 1 LIMIT 1 HYST AL t ON t OFF ok gn ok ye fail t OFF ok al rd alarm t ON t OFF ok al Alarm delay: AL t ON t OFF Connection diagram N L1 L2 L3 ok al I1– I1+ al t OFF, t ON I2– I2+ LOAD t ON AL1 Measuring circuit data Over/under current setting ranges AC / DC Frequency Resolution Accuracy Input resistance 0…5A DC, AC 16 … 100 Hz 100 mA 2 % ±1 digit 5 mΩ Time data Alarm delay setting time Reset time setting range Voltage failure buffering 0.1 … 999.9 s 0.1 … 999.9 s ca. 30 ms Contacts Type / Material Rated operational current Max. inrush current Max. switching voltage Max. AC load AC-1 (Fig.1) Max. DC load DC-1, 24 V / 220 V (Fig.2) Recommended min. contact load 2 CO / AgNi 0.15 6A 15 A 250 V 1250 VA 120 W / 25 W 10 mA / 10 V Power supply Nominal voltage AC/DC Operating voltage range AC frequency Power consumption UC12-48V 12 … 48 V 10 … 57 V 16 … 63 Hz 2 W / 3 VA I3– I3+ AL2 15 16 18 25 26 28 A1 A2 Fig. 1 AC voltage enduranc Cycles 107 AC-1 106 105 0 1 2 3 4 Switching current [A] 5 6 Fig. 2 DC load limit curve 10 DC-1 Current [A] 6 5 UC110-240V 110 … 240 V 85 … 250 V 16 … 63 Hz 2 W / 3 VA 3 2 1 0.5 0.3 0.2 Insulation Test voltage open - contact Test voltage between poles Test voltage measuring input - contacts Test voltage measuring input - power supply 1 kVrms 1 minute 2.5 kVrms 1 minute 4 kVrms 1 minute 4 kVrms 1 minute General specifications Ambient temperature storage /operation Mechanical life of contacts Conductor cross section Ingress protection rating Max. screw torque Housing material Weight -40 … +85 °C / -25 … +60 °C 30 x 106 operations Stranded wire 2.5 mm2, 2 x 1.5 mm2 IP20 0.4 Nm Lexan EXL 9330 130 g 0.1 0 50 100 150 200 Voltage [V] 250 300 Dimensions [mm] Standard types UC 12-48 V (AC/DC), 15…60 Hz UC 110-240 V (AC/DC, 15…60 Hz MRI32R/UC12-48V MRI32R/UC110-240V Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Monitoring Relays AL INPUT LOAD INPUT HYST LIMIT1 LOAD INPUT HYST LIMIT2 Railway/01a.12 | 37 1-phase monitoring MRM11R Multifunction monitoring relay AC/DC, single phase DIN Rail mounting according to DIN 43 880 Type: MRM11R/…V Multifunctional monitoring relay for simultaneous measurement of current and voltage and monitoring of U, I, P, cosφ and f. Alarm delay setting. Alarm LED. Display for multimeter function, alarm signal and interactive parameter setting. 1 change-over alarm contact 6 A 250 V. Comfortable parameter setting. Monitoring function LIMIT 1 HYST 1 LIMIT 1 HYST INPUT INPUT HYST LIMIT2 HYST LIMIT1 AL AL t OFF ok ok ye fail t OFF ok al rd alarm t ON t OFF ok al Alarm delay: AL t ON t OFF Connection diagram N ok al L U– U– al t OFF, t ON LOAD t ON Measuring circuit data Voltage setting ranges AC / DC Current setting ranges AC / DC Frequency Resolution U / I Accuracy Input resistance U / I 0 … 480 V / 0 … 690 V 0…5A DC, AC 16 … 100 Hz 100 mV / 100 mA 2 % ±1 digit 1 MΩ / 5 mΩ Time data Alarm delay setting time Reset time setting range Voltage failure buffering 0.1 … 999.9 s 0.1 … 999.9 s ca. 30 ms Contacts Type / Material Rated operational current Max. inrush current Max. switching voltage Max. AC load AC-1 (Fig.1) Max. DC load DC-1, 24 V / 220 V (Fig.2) Recommended min. contact load 1 CO / AgNi 0.15 6A 15 A 250 V 1250 VA 120 W / 25 W 10 mA / 10 V Power supply Nominal voltage AC/DC Operating voltage range AC frequency Power consumption UC12-48V 12 … 48 V 10 … 57 V 16 … 63 Hz 2 W / 3 VA I– U/I+ AL 15 16 18 A1 A2 Fig. 1 AC voltage enduranc Cycles 107 AC-1 106 105 0 1 2 3 4 Switching current [A] 5 6 Fig. 2 DC load limit curve 10 DC-1 6 5 UC110-240V 110 … 240 V 85 … 250 V 16 … 63 Hz 2 W / 3 VA Current [A] t ON gn INPUT 2 1 0.5 0.3 0.2 Insulation Test voltage open - contact Test voltage measuring input - contacts Test voltage measuring input - power supply 1 kVrms 1 minute 4 kVrms 1 minute 4 kVrms 1 minute General specifications Ambient temperature storage /operation Mechanical life of contacts Conductor cross section Ingress protection rating Max. screw torque Housing material Weight -40 … +85 °C / -25 … +60 °C 30 x 106 operations Stranded wire 2.5 mm2, 2 x 1.5 mm2 IP20 0.4 Nm Lexan EXL 9330 130 g 0.1 0 50 100 150 200 Voltage [V] 250 300 Dimensions [mm] Standard types UC 12-48 V (AC/DC), 15…60 Hz UC 110-240 V (AC/DC), 15…60 Hz MRM11R/UC12-48V MRM11R/UC110-240V Technical approvals, conformities See table on page 53. 38 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. 3-phase monitoring MRM32R Multifunction monitoring relay AC/DC, three phase DIN Rail mounting according to DIN 43 880 Type: MRM32R/…V Multifunctional monitoring relay for simultaneous measurement of current and voltage and monitoring of U, I, P, cosφ and f and Δφ. Alarm delay setting. Alarm LED. Display for multimeter function, alarm signal and interactive parameter setting. 2 change-over alarm contacts 6 A 250 V. Comfortable parameter setting. Monitoring function LIMIT 1 HYST 1 LIMIT 1 HYST AL t ON t OFF ok gn ok ye fail t OFF ok al rd alarm t ON t OFF ok al Alarm delay: AL t ON t OFF Connection diagram N L1 L2 L3 ok al al t OFF, t ON LOAD t ON U– U– I1– U/I1+ I2– U/I2+ I3– U/I3+ AL1 Measuring circuit data Voltage setting ranges AC / DC Current setting ranges AC / DC Frequency Resolution U / I Accuracy Input resistance U / I 0 … 480 V / 0 … 690 V 0…5A DC, AC 16 … 100 Hz 100 mV / 100 mA 2 % ±1 digit 1 MΩ / 5 mΩ Time data Alarm delay setting time Reset time setting range Voltage failure buffering 0.1 … 999.9 s 0.1 … 999.9 s ca. 30 ms Contacts Type / Material Rated operational current Max. inrush current Max. switching voltage Max. AC load AC-1 (Fig.1) Max. DC load DC-1, 24 V / 220 V (Fig.2) Recommended min. contact load 2 CO / AgNi 0.15 6A 15 A 250 V 1250 VA 120 W / 25 W 10 mA / 10 V Power supply Nominal voltage AC/DC Operating voltage range AC frequency Power consumption UC12-48V 12 … 48 V 10 … 57 V 16 … 63 Hz 2 W / 3 VA AL2 15 16 18 25 26 28 A1 A2 Fig. 1 AC voltage enduranc Cycles 107 AC-1 106 105 0 1 2 3 4 Switching current [A] 5 6 Fig. 2 DC load limit curve 10 DC-1 Current [A] 6 5 UC110-240V 110 … 240 V 85 … 250 V 16 … 63 Hz 2 W / 3 VA 3 2 1 0.5 0.3 0.2 Insulation Test voltage open - contact Test voltage between poles Test voltage measuring input - contacts Test voltage measuring input - power supply 1 kVrms 1 minute 2.5 kVrms 1 minute 4 kVrms 1 minute 4 kVrms 1 minute General specifications Ambient temperature storage /operation Mechanical life of contacts Conductor cross section Ingress protection rating Max. screw torque Housing material Weight -40 … +85 °C / -25 … +60 °C 30 x 106 operations Stranded wire 2.5 mm2, 2 x 1.5 mm2 IP20 0.4 Nm Lexan EXL 9330 130 g 0.1 0 50 100 150 200 Voltage [V] 250 300 Dimensions [mm] Standard types UC 12-48 V (AC/DC), 15…60 Hz UC 110-240 V (AC/DC), 15…60 Hz MRM32R/UC12-48V MRM32R/UC110-240V This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Monitoring Relays AL INPUT LOAD INPUT HYST LIMIT1 LOAD INPUT HYST LIMIT2 Technical approvals, conformities See table on page 53. Railway/01a.12 | 39 CT-System Plug-in current monitoring modules (to combine with industrial relays) CT512R, CT515R, CT516R Plug-in current monitoring module; 0.2 A, 2 A, 6 A. DC 24 V operation Type: CT512R, CT515R, CT516R /… V Plug-in current monitoring modules for sockets with module slot in combination with plug-in relays. DC 24 V operation. LED alarm state indicators for OK and fail. Separate adjustment of upper and lower level. Monitoring functions Connection diagram Over / under voltage internal / external range Measuring circuit data Type Measuring and setting ranges (rotary knobs) Max. current 100% duty cycle Voltage drop on internal shunt res. @ Imax Temperature drift -25 … 60 °C CT512R 0 … 200 mA 300 mA 300 mV ≤ 3 % Time data Alarm delay time settings Reset time 100 ms, 500 ms, 2 s 100 ms Power supply Nominal voltage Operation voltage range Supply current Polarity reversal protection DC 24 V 18 … 30 V 3 … 7 mA - 30 V General specifications Ambient temperature storage/operation Ingress protection rating Housing material Weight -40 … +85 °C / -40 … +70 °C IP 40 when plugged in Lexan 25 g CT515RCT516R 0 … 2 A 0…6A 3 A 7A 200 mV 100 mV ≤ 3 % ≤3% DC 36 V 18 … 45 V 5 mA - 51 V Standard types CT512R CT515R CT516R CT512R/DC24V CT515R/DC24V CT516R/DC24V CT512R/DC36V CT515R/DC36V CT516R/DC36V Remark: This module is part of several ready for connection units consisting of ­socket, relay and module. A wide variety of suitable relays is available. Dimensions [mm] 16 75 4 38 4 20 54 Technical approvals, conformities See table on page 53. 40 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. CT-System Plug-in DC voltage monitoring module (to combine with industrial relays) CT524R, plug-in DC voltage monitoring module Plug-in DC voltage monitoring module Type: CT524R /…V Plug-in DC voltage monitoring module for sockets with module slot in combination with 11p plug-in relays. DC 24 V operation. LED alarm state indicators for OK and fail. Separate adjustment of upper and lower level. Monitoring functions Connection diagram Over / under voltage internal / external range Time data Alarm delay time settings Reset time 100 ms, 500 ms, 2 s 100 ms Power supply Nominal voltage Operation voltage range Supply current Polarity reversal protection (1 minute) DC 24 V 18 … 30 V 8 … 13 mA - 30 V General specifications Ambient temperature storage/operation Ingress protection rating Housing material Weight -40 … + 85 °C / -40 … +70 °C IP 40 when plugged in Lexan 25 g Monitoring Relays Measuring circuit data TypeCT524R Measuring and setting ranges (rotary knobs) 0 … 30 V Over voltage (10 ms) ± 150 V Input resistance 106 kΩ Temperature drift -25 … 60 °C ≤2% Standard types CT524R 3 CT524R/DC24V Remark: This module is part of several ready for connection units consisting of ­socket, relay and module. A wide variety of suitable relays is available. Dimensions [mm] 16 75 4 38 4 20 54 Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01a.12 | 41 Plug-in monitoring Set CT-System Power Relay Control Relay C31L C32L DC Voltage Monitoring-Set DC Current Monitoring-Set Set-Delivery includes: •Relay •Module •Front cover •Socket •Retaining clip Relay data‘s see: Section industrial Relays Universal Power Relay 10A with 3 power change-overcontacts this is the robust relay for AC and DC circuits ranging from 50mA 10V. 10A 250VA 6A 250VA MIN 50mA 10V 10mA 5V CT524 DC Voltage Monitoring 0-30V 40V B1 A1 A2 + Input resistance B1 ➞ A2: 100kΩ R A2 35 25 15 B1 A1 DC Current Monitoring 10 11 6 1 12 2 Set Order-Nr.: Set Order-Nr.: 0-200mA 300mA Delivery includes: •Relay C32D/R DC24V •Module CT524R/DC24V •Front cover FS-C •Socket C12B0 •Retaining clip HF-32 Set Order-Nr.: Set Order-Nr.: DC 24, 36V B1 A1 RL CT524.32R/24V Delivery includes: •Relay C31D/R DC24V •Module CT524R/DC24V •Front cover FS-C •Socket C12B0 •Retaining clip HF-32 CT512.31R/…V A2 A2 35 25 15 B1 A1 10 11 6 1 12 2 + CT512 Triggering R CT524.31R/24V V in Range: I max: 38 36 28 26 18 16 TIMER-MODUL 4 functions can be selected: Overvoltage / undervoltage monitoring with adjustable hysteresis or 2 range monitors (INT or EXT). Adjustable alarm delay. LED display for errors and ok. Contact inspection window at the top. Manual safety operation. Module see page 40 / 41 9 8 7 5 3 4 38 36 28 26 18 16 TIMER-MODUL Monitoring Module Triggering The control relay with highest switching reliablility for control and signal circuits ranging from 10mA 5V. MAX 9 8 7 5 3 4 Range: U max: Relay with 3 twin contacts 6A Voltage drop A1 ➞ B1 ≤ 300mV in CT512.32R/…V DC 24, 36V Delivery includes: • Relay C31D/R DC…V • Module CT512R/DC…V • Front cover FS-C • Socket C12B0 • Retaining clip HF-32 Delivery includes: • Relay C32D/R DC…V • Module CT512R/DC…V • Front cover FS-C • Socket C12B0 • Retaining clip HF-32 Set Order-Nr.: Set Order-Nr.: + CT515 DC Current Monitoring Range: I max: CT515.31R/…V 0-2A 3A Triggering DC 24, 36V A2 B1 A1 RL Voltage drop A1 ➞ B1 ≤ 200mV in CT515.32R/…V DC 24, 36V Delivery includes: • Relay C31D/R DC…V • Module CT515R/DC…V • Front cover FS-C • Socket C12B0 • Retaining clip HF-32 Delivery includes: • Relay C32D/R DC…V • Module CT515R/DC…V • Front cover FS-C • Socket C12B0 • Retaining clip HF-32 Set Order-Nr.: Set Order-Nr.: + CT516 DC Current Monitoring CT516.31R/…V CT516.32R/…V 0-6A 7A DC 24, 36V DC 24, 36V Range: I max: Triggering A2 B1 A1 RL in + 42 | Railway/01a.12 Voltage drop A1 ➞ B1 ≤ 100mV Delivery includes: • Relay C31D/R DC…V • Module CT516R/DC…V • Front cover FS-C • Socket C12B0 • Retaining clip HF-32 Delivery includes: • Relay C32D/R DC…V • Module CT516R/DC…V • Front cover FS-C • Socket C12B0 • Retaining clip HF-32 Dimensions [mm] See page 40. Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Insulation monitoring ESU-D2R Insulation monitoring relay for unearthed DC-networks DIN Rail mounting Type: ESU-D2R/UC24V Earth insulation resistance monitoring relay Pre alarm 1 CO and main alarm 1 NO + 1 CO contact outputs 5 A / 250 V UC 24 … 48 V, operating voltages, monitoring of DC 12 … 48 V power supply networks. Monitoring of earth interruption on the device. The device measures single or combined resistances occurring against + or – pole of the DC network. Adjustable alarm delay. Proved reliability in rolling stock applications. Monitoring function The ESU-D2 monitors the isolation resistance in nongrounded DC-networks (24 – 48 V). Two alarm steps (prealarm AL1 and main alarm AL2) are indicated via separate output contacts. Displays: bargraph-display of the measured earthing resistance (green = ok). Two red LEDs show the ground tendency towards plus (+) or minus (–). Output terminals 5 V for the external display of the earthing resistance (0,1 V/kΩ). Test functions: Periodic automatic check, also with key “Test”. Environmental failures: monitoring of AC-short circuit, overvoltage, ground interruption. V 1 … 50 kΩ / 4 … 30 kΩ 4 kΩ ≤ 10 % 60 V ≤ 5 mA 0.2 mA AC 250 V 1.5 µF 1) Only one ESU-D2 per DC network! 0.1 … 10 s 600 ms 1s Monitoring Relays Connect E1, E2 separately on E. Fig. 2 DC load limit curve 5 4 3 DC-1 2 Contacts Type / Material Rated operational current / min. contact load Max. switching voltage (Fig. 1) 2 CO, 1 NO micro disconnection / AgNi 5 A / 1 mA 12 V 250 V Power supply Nominal voltage Operation voltage range Power consumption Voltage failure buffering UC 24-48 V 16.8 … 60 V 2W ≥ 50 ms 1 3 0.5 0.2 0.1 0 50 100 150 200 Voltage [V] 250 300 2 kVrms 1 minute General specifications Ambient temperature storage /operation Ingress protection rating Max. screw torque Weight -40 … +85 °C / -40 … +70 °C Housing: IP 40, terminals: IP 20 0.5 Nm 250 g Standard types 75 Dimensions [mm] Insulation Test voltage contacts to other circuits UC24-48 (AC/DC) Pre alarm Main alarm Types for capacitances until 60 µF on request Time data Alarm delay time adjustment range Fault detection time Auto reset time, fail to OK Installation to be monitored DC 0.. 52V Current [A] 1) + TS35 Measuring circuit data Measuring / setting range for pre alarm Constant value for main alarm Tolerance Overvoltage alarm level of DC network Input current + → - Sampling current pulses +/- → earth Overvoltage safety from earth to +/- poles Max. capacity +/- → earth Connection diagram 50 ESU-D2R/UC24-48V 5 105 Pluggable terminal blocks Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01a.12 | 43 Notes 44 | Railway/01a.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. 4.Sockets Rated load Socket for 11 pin relays and plug-in modules C11A 10 A, 250V Socket for 11 pin relays and plug-in modules C12B0 10A, 250V Socket for 14 pin relays CS-144 10A, 250V Socket for miniature relays CS-118 10A, 250V Pins Sockets ApplicationTypes 4 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01.12 | 45 C11A Socket for 11 pin plug-in relays C31D/R, C32D/R, R3-N3x and plug-in modules Type: C11A 3-pole, 1 level Module slot for over voltage suppressing and LED indicator modules, coil bridge bus bar to connect in A2 Rated current Specifications Rated load Insulation – All terminals/DIN rail – Terminal/terminal Cross-section of connecting wire – Multi-wire Max. screw torque Screw dimensions Labelling space Connection label Mounting Ambient temperature operation / storage Weight 10 A 10 A Test voltage Vrms / 1 min 2.5 kV 2.5 kV 1 x 4 mm2, 2 x 2.5 mm2 0.7 Nm M3, Pozi, slot detachable 1...11; DIN / EN DIN rail TS35 or panel mounting -40 (no ice) … +70 ºC / -40 … + 85 °C 56 g Associated plug-in 11-pin relays C31D/R, C32D/R and R3-N3x Type C11A Connection diagram 10 (A2) 9 (34) 11 (31) 8 (32) 6 (21) 7 (24) 1 (11) 5 (22) 3 (14) 2 (A1) 4 (12) Accessories Retaining springs, steel HF-32 (Relays C31, C32) HF-33 (Timecube + Relays C31, C32) S3-C (Relays R3-N3x) Coil bridge bus bar C-A2 Marking strip cardboard white 8 x 16L-16/5 (under transp. plastic cover) Illuminated display RL1/… Suppressing unit RC1/… RCL1/… RD1/… Dimensions [mm] Technical approvals, conformities See table on page 53. 46 | Railway/01.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. C12B0 Socket for 11 pin plug-in relays C31D/R, C32D/R, R3-N3x and plug-in control modules Type: C12B0 3-pole, 1 level Module slot for timer- and monitoring modules, over voltage suppressing and LED indicator modules coil bridge bus bar to connect in A2 Rated current Specifications Rated load Insulation – All terminals/DIN rail – Terminal/terminal Cross-section of connecting wire – Multi-wire Max. screw torque Screw dimensions Labelling space Connection label Mounting Ambient temperature operation / storage Weight 10 A 10 A Test voltage Vrms / 1 min 2.5 kV 2.5 kV 1 x 4 mm2, 2 x 2.5 mm2 0.7 Nm M3, Pozi, slot detachable 1...12; DIN/EN DIN rail TS35 or panel mounting -40 (no ice) … +70 ºC / -40 … +85 °C 61 g Associated plug-in 11-pin relays C31D/R, C32D/R and R3-N3x Type C12B0 Connection diagram 10 (A2) 9 (34) 11 (31) 8 (32) 6 (21) 7 (24) 1 (11) 5 (22) 12 (B1) 3 (14) 2 (A1) 4 (12) Accessories Retaining springs, steel HF-32 (Relays C31, C32) HF-33 (Timecube + Relays C31, C32) S3-C (Relays R3-N3x) Coil bridge bus bar C-A2 Marking strip cardboard white 8 x 16L-16/5 (under transp. plastic cover) Illuminated display RL1/… Suppressing unit RC1/… RCL1/… RD1/… Sockets Dimensions [mm] 4 Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01.12 | 47 CS-144 Socket for 14-pin plug-in relays R4-Ax Type: CS-144 4-pole, 2 connection level Integrated retaining clip and labelling space Rated current Specifications Rated load Insulation – All terminals/DIN rail – Terminal/terminal Cross-section of connecting wire – Single-wire – Multi-wire Max. screw torque Screw dimensions Integrated retaining clip/plastic Labelling space Connection label Mounting Ambient temperature operation / storage Weight 10 A 10 A / 250 V Test voltage Vrms / 1 min 2.5 kV 2.5 kV 4 mm2 or 2 x 2.5 mm2 22 - 14 AWG 1 Nm M3.5, Pozi, slot for relay series C4 detachable 1...14; DIN/EN DIN rail TS35 or panel mounting -40 (no ice) … +70 ºC / -40 … +80 °C 80 g Associated, plug-in 14-pin relays R4-A4x Type CS-144 Accessories Retaining spring, steel Retaining clip, plastic S4-C S3-CMG Connection diagram 12 (41) 14 (A2) 10 (42) 11 (44) 9 (31) 7 (32) 8 (34) 6 (21) 4 (22) 5 (24) 1 (12) 2 (14) 3 (11) 13 (A1) Dimensions [mm] 11 44 8 34 5 24 2 14 10 42 7 32 4 22 1 12 3.6 ø4 7 4 1 11 8 5 2 6 9 14 Incl. Clip 7 3 12 M4/M5 92 10 21 7 32 4 22 1 12 13 CS-144 14 A2 13 A1 12 41 9 31 6 21 3 11 38 3 29 Technical approvals, conformities See table on page 53. 48 | Railway/01.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. CS-118 Socket for miniature plug-in relays R7-A, R7-T Type: CS-18 2-pole, 1 level integrated clip and marking label suitable for C80 series time relays with clip coil bridge bus bar to connect in A2 plug-in slot for overvoltage suppressing units Rated current 10 A Specifications Rated load Insulation – All terminal/DIN rail – Terminal/terminal Cross section of connecting wire – Single wire – Multi wire Max. screw torque Screw dimensions Integrated retaining clip/plastic Labelling space Connection label Mounting Ambient temperature operation / storage Weight 4 mm2, 2 x 1.5 mm2 2.5 mm2 / AWG 16, 2 x 1 mm2 / AWG 18 0.7 Nm M3, Pozi, slot for relays C7 detachable 1…8, DIN/EN DIN rail TS35 or panel mounting -40 (no ice) … +70 °C / -40 … +80 °C 37 g Associated plug-in 8-pin relays R7-A, R7-T Type CS-118 Accessories Coil bridge bus bar Retaining clip, plastic S7-B RC-G 10 A / 250 V Test voltage Vrms / 1 min 2.5 kV 2.5 kV Connection diagram 8 (A2) 4 (24) 6 (21) 2 (22) 5 (11) 3 (14) 7 (A1) 1 (12) Sockets Dimensions [mm] 4 Technical approvals, conformities See table on page 53. This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01.12 | 49 Notes 50 | Railway/01.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Sockets Notes 4 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01.12 | 51 Notes 52 | Railway/01.12 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Technical approvals, conformities YES YES NO N/A Category 1, Class B F2 I3 E120922 YES YES YES NO N/A Category 1, Class B F2 I3 E120922 R3-N3… T3 YES R4-A4… T1 YES R7-A2… T3 YES R7-T2… T3 YES C203.6R TX YES YES YES NO YES Category 1, Class B F2 I3 HL2 HL2 CINT-21 TX YES NO YES NO NO Category 1, Class B F2 I3 HL2 HL2 CINT-22 TX YES NO YES NO NO Category 1, Class B F2 I3 HL2 HL2 CINT-25 T2 YES NO YES NO NO Category 1, Class B F2 I3 HL2 HL2 CINT-61 TX YES NO YES NO NO Category 1, Class B F2 I3 HL2 HL2 CINT-62 TX YES NO YES NO NO Category 1, Class B F2 I3 HL2 HL2 CINT-63 TX YES NO YES NO NO Category 1, Class B F2 I3 HL2 HL2 C2 Listed YES C1 R24 TX TX S2 R23 C31D/R C32D/R Type Power supply S1 Inflammability I UL Smoke gas index F EN 45545-2 Schock & vibrations test NF F 16-101/102 Protective coating PCB EN 61373 Temperature rating EN 50155 Relays Category 1, Class B Approval in process Category 1, Class B Category 1, Class B Time relays RIC20-… YES YES YES NO NO In approval RIC25-… YES YES YES NO NO Category 1, Class B CIM1R TX YES YES YES YES YES Category 1, Class B F2 I3 HL2 HL2 CIM12R TX YES YES YES YES YES Category 1, Class B F2 I3 HL2 HL2 CIM13R TX YES YES YES YES YES Category 1, Class B F2 I3 HL2 HL2 CIM2R TX YES YES YES YES YES Category 1, Class B F2 I3 HL2 HL2 CIM22R TX YES YES YES YES YES Category 1, Class B F2 I3 HL2 HL2 CIM23R TX YES YES YES YES YES Category 1, Class B F2 I3 HL2 HL2 CIM3R TX YES YES YES YES YES Category 1, Class B F2 I3 HL2 HL2 CIM32R TX YES YES YES YES YES Category 1, Class B F2 I3 HL2 HL2 CIM33R TX YES YES YES YES YES Category 1, Class B F2 I3 HL2 HL2 CT32R (modul) TX YES YES YES NO YES Category 1, Class B F2 I3 HL2 HL2 HL2 HL2 HL2 HL2 HL2 HL2 HL2 HL2 HL2 HL2 HL2 HL2 CT32.31R (set) TX YES YES YES NO YES Category 1, Class B F2 I3 CT32.32R (set) TX YES YES YES NO YES Category 1, Class B F2 I3 CT33R (modul) TX YES YES YES NO YES Category 1, Class B F2 I3 CT33.31R (set) TX YES YES YES NO YES Category 1, Class B F2 I3 CT33.32R (set) TX YES YES YES NO YES Category 1, Class B F2 I3 CT36R (modul) TX YES YES YES NO YES Category 1, Class B F2 I3 CT36.31R (set) TX YES YES YES NO YES Category 1, Class B F2 I3 CT32.32R (set) TX YES YES YES NO YES Category 1, Class B F2 I3 Monitoring relays CT512R (modul) TX YES YES YES NO YES Category 1, Class B F2 I3 CT512.31R (set) TX YES YES YES NO YES Category 1, Class B F2 I3 I3 CT512.32R (set) TX YES YES YES NO YES Category 1, Class B F2 CT515R (modul) TX YES YES YES NO YES Category 1, Class B F2 I3 CT515.31R (set) TX YES YES YES NO YES Category 1, Class B F2 I3 CT515.32R (set) TX YES YES YES NO YES Category 1, Class B F2 I3 CT516R (modul) TX YES YES YES NO YES Category 1, Class B F2 I3 CT516.31R (set) TX YES YES YES NO YES Category 1, Class B F2 I3 CT516.32R (set) TX YES YES YES NO YES Category 1, Class B F2 I3 CT524R (modul) TX YES YES YES NO YES Category 1, Class B F2 I3 CT524.31R (set) TX YES YES YES NO YES Category 1, Class B F2 I3 CT524.32R (set) TX YES YES YES NO YES Category 1, Class B F2 I3 F2 I3 MRI11R Approval in process MRI32R Approval in process MRM11R Approval in process MRM32R Approval in process MRU11R Approval in process MRU32R ESU-D2R Approval in process TX YES YES YES YES YES Category 1, Class B Sockets C11A TX N /A N /A N /A N /A N /A Category 1, Class B F2 I3 HL2 HL2 E120922 C12B0 TX N /A N /A N /A N /A N /A Category 1, Class B F2 I3 HL2 HL2 E120922 CS-118 TX N /A N /A N /A N /A N /A Approval in process F2 I3 HL2 HL2 E196531 CS-144 TX N /A N /A N /A N /A N /A Category 1, Class B F2 I3 HL2 HL2 E196531 This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Railway/01.12 | 53 railway/01a.2012E Comat Ag • Bernstr. 4 CH-3076 Worb Tel. +41 (0)31 838 55 77 Fax +41 (0)31 838 55 99 www.comat.ch • info@comat.ch